BLDG. CODES & SAFETY CODES PERTAINING TO SEISMIC ZONE · 2020. 8. 25. · IS 1893(Part 1):2002...
Transcript of BLDG. CODES & SAFETY CODES PERTAINING TO SEISMIC ZONE · 2020. 8. 25. · IS 1893(Part 1):2002...
Webinar on.....Earthquake Resistant Construction of Buildings
Date :- 28/07/2020
Time :- 4:00 to 5:20
Session :- 3
Regulation & Enforcement
◦ Bldg. Codes & Safety Codes pertaining to seismic
zone.
◦ Building Bye-Laws.
◦ Licensing & Certification of Engineers & Architects.
◦ Technical Audit & Monitoring.
Topic Conducted By......Er. C.B.Bhatt, Surveyor, Bhuj ADA, Bhuj-Kutchh
1
Bldg Codes & Safety Codes Pertaining to Seismic Zone
Indian Standards on Earthquake Engineering :-
National Standard Body of India, is a Statutory Organization under theBureau of Indian Standards Act 1986.
Formulation of Indian Standards on different subjects of Engineering throughvarious Division Councils.
The Civil Engineering Division Council :- standardization in the field of CivilEngineering including
A) Structural Engineering,
B) Building materials and components,
C) Planning Design
D) Construction and Maintenance of Civil Engineering Structures
E) Construction Practices
F) Safety in Building etc.
These standards are evolved based on consensus principle through anetwork of technical committee comprising representatives from Govt. &Non Govt Organizations.
2
IS 1893:1984 Criteria for Earthquake
Resistant Design of Structures
Deals with earthquake resistant design of
structures and is applicable to buildings;
elevated structures; bridges; dams etc.
Also gives a map which divides the country
into five seismic zones based on the seismic
intensity.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
3
IS 1893(Part 1):2002 Criteria for Earthquake Resistant
Design of Structures : Part 1 General provisions and
Buildings’ :-
Contains provisions that are general in nature and applicable to all
structures.
Also contains provisions that are specific to buildings only.
Covers general principles and design criteria, combinations, design
spectrum, main attributes of buildings, dynamic analysis, apart from
seismic zoning map and seismic coefficients of important towns, map
showing epicenters, map showing tectonic features and lithological map
of India.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
4
IS 1893(Part 4):2005 `Criteria for Earthquake Resistant Design of Structures: Part 4 Industrial Structures Including Stack Like Structures
This standard deals with earthquake resistant design of the industrial structures (plant and auxiliary structures) including stack-like structures such as process industries, power plants, textile industries, off-shore structures and marine/port/harbour structures.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
5
IS 4326:1993 Earthquake Resistant Design and Construction of Buildings - Code of Practice
Provides guidance in selection of materials, special features ofdesign and construction for earthquake resistant buildings includingmasonry construction, timber construction, prefabricatedconstruction etc.
In this standard, it is intended to cover the specified features ofdesign and construction for earthquake resistance of buildings ofconventional types.
The general principles to be observed in the construction of suchearthquake resistant buildings as specified in this standard areLightness, Continuity of Construction, avoiding/reinforcingProjecting and suspended parts, Building configuration, strength invarious directions, stable foundations, Ductility of structure,Connection to non-structural parts and fire safety of structures.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
6
IS 13827:1993 Improving Earthquake Resistance of Earthen Buildings –Guidelines
The guidelines covered in this standarddeal with the design and constructionaspects for improving earthquakeresistance of earthen houses, without theuse of stabilizers such as lime, cement,asphalt, etc.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
7
IS 13828:1993 Improving Earthquak
e Resistance of Low Strength
Masonry Buildings – Guidelines
Covers the special features of design and
construction for improving earthquake
resistance of buildings of low-strength
masonry.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
8
IS 13920:1993 Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces –Code of Practice
Covers the requirements for designing and detailing ofmonolithic reinforced concrete buildings so as to give themadequate toughness and ductility to resist severe earthquakeshocks without collapse.
Material specifications are indicated for lateral force resistingelements of frames.
The provisions are also given for detailing of reinforcementin the wall web, boundary elements, coupling beams, aroundopenings, at construction joints, and for the development,splicing and anchorage of reinforcement.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
9
IS 13935:2009 Seismic Evaluation, Repair and Strengthening of Masonry Buildings – Guidelines
Covers the selection of materials andtechniques to be used for repair and seismicstrengthening of damaged buildings duringearthquakes.
Also covers the damageability assessmentand retrofitting for upgrading of seismicresistance of existing masonry buildingscovered under IS 4326 and IS 13828.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
10
SP 7 : 2016
National Building Code of India 2016 (NBC 2016)
First published -1970 at the instance of Planning Commission
First revised -1983.
Three major amendments were issued to the 1983 version, two in 1987 andthe third in 1997. S
Second revision - 2005, to which two amendments were issued in 2015.
The National Building Code of India (NBC), a comprehensive building Code, isa national instrument providing guidelines for regulating the buildingconstruction activities across the country.
Serves as a Model Code for adoption by all agencies involved in buildingconstruction works be they Govt or Non Govt agencies.
Mainly contains administrative regulations, development control rules andgeneral building requirements; fire safety requirements; stipulations regardingmaterials, structural design and construction (including safety); building andplumbing services; approach to sustainability; and asset and facilitymanagement.
Bldg Codes & Safety Codes Pertaining to Seismic Zone
11
Building Bye Laws :
Earlier there are different Dev. Control Regulations in differentUrban areas of state
In year 2017 Govt. introduced CGDCR-2017 to avail ease &uniformity in interpretation & appropriated enforcement ofDevelopment Control Regulations.
Government has prepared a comprehensive document for smoothimplementation & interpretation of Regulations under GujaratTown Planning & Urban Development Act - 1976
It is called as Comprehensive General Development ControlRegulations – 2017, which is finalized wide Govt. NotificationDt.03/10/2019
All urban Development Authorities, Area Development Authorities& Municipal Corporations classified in D1 to D10 categories
Which is divided in three parts
Part I :- Procedure Regulations
Part II :- Planning Regulations
Part III :-Performance Regulations
12
CGDCR – 2017
Part I :- Procedure Regulations (Legal Part)
Definitions
Dev. Permission & B.U. Permission
Responsibilities of Owner &/or Developer & POR
Procedure during construction
Schedules & Forms
Building Bye Laws :
13
CGDCR – 2017
Part II :- Planning Regulations (Enforcement Part)
General Planning & Dev. Regulations
FSI, Margin, Parking, Dev. of Land etc.,
Gamtal & Core Walled city
Other than Gamtal & Core Walled city
Mining, quarrying & Brick Inn
Advertising Display & Communication Infrastructure
Building Bye Laws :
14
New Construction on
9mts Road in GamtalNew Construction on
12mts Road in Gamtal
TOWN PLANNING SCHEMES
BHUJ DEVELOPMENT PLAN
OFFICE
TREASURY
MOHAMMADPANAHMASJID
ALFREDHIGH SCHOOL
PROPOSED 24 M WIDE DEVELOPMENT PLAN ROAD
Before re-planning the area
TOWN PLANNING SCHEMES
OFFICE
TREASURY
MOHAMMADPANAH
MASJID 12 M
T S
.
W
I D
E
R
O A
D
12 M
T S
. W
I D
E R
O A
D
12 M
T S
. W
I D
E R
O A
D
12 M
T S
. W
I D
E R
O A
D
7.5 M T S. W I D E R O A D
W I D
E R
O A
D
7.5 M T S. W I D E R O A D
7.5
M T
S.
7.5 M T S. W I D E R O A D
7.5 M T S. W I D E R O A D
6 M T S. W I D E R
O A D
6 M T S. W I D E R O A D
6 M T S. W I D E R O A D
6 M T S.
W I D
E R O A D
4.5
M
T S
. W
I D
E R
O A
D
4.5
M
T S
. W
I D
E R
O A
D
4.5
M
T S
. W
I D
E R
O A
D
4.5
M T
S. W
I D E
R O
A D
3 M
T S
. W I D
E R
O A
D
4.5
M T
S. W
I D E
6 M T S. W I D E R O A D
4.5 M T S. W I D E R O A D
4.5 M T S. W I D E R O A D
4.5
M T
S.
W I D
E R O A D
4.5
M
T S
. W
I D
E
3 M T S. W I D E R O A D
4.5
M
T S
. W
I D
E
4.5
M T
S. W
I D E
4.5 M T
S. W
I D E
3 M
T S
. W I D
E
R O
A D
6 M
T S
. W I D
E R
O A
D
3M
T S
. W I D
E
3 M
T S
. W I D
E
R O
A D
4.5
M T
S. W
I D E
R O
A D
3 M
T S
. W I D
E
3 M T S. W I D E R O
A D
3 M T S. W I D E
3 M
T S
. W I D
E
3 M T S. W I D E R O A D
3 M T S. W I D E
2.5
M T
S. W
I D E
R O
A D
9 M T S. W I D E R O A D
12 M T S. W I D E R O A D
9 M
T S
. W
I D
E R
O A
D
3 M
T S
. W
I D
E
4.5
M T
S. W
I D E
R O
A D
3 M
T S
. W I D
E
3 M
T S
. W I D
E
3 M T S. W I D E
4.5 M T S. W I D E
6 M
T S
. W
I D
E R
O A
D
4.5
M T
S.
W I
D E
R
O A
D
4.5
M
T S
. W
I D
E
3 M T S. W I D E
4.5 M T S. W I D E R O A D
3 M T S. W I D E
ALFREDHIGH SCHOOL
4.5
M
T S
. W
I D
E R
O A
D
6 M
T S
. W I D
E R
O A
D
PROPOSED DEVELOPMENT PLAN ROAD - 24 M WIDE
After re-planning the area
TOWN PLANNING SCHEMES
Ravalwadi Relocation Site
Mundra Relocation Site
CGDCR – 2017 Part III :- Performance Regulations (Enforcement Part)
Building & Infrastructure
Architectural Elements, Parkign, Lighting, Ventilation, Drainage etc.,
Fire Prevention & Safety
Special Buildings performance Regulations
Structural Safety
Environmental Management
Pollution Control
Maintenance & Up gradation
Conformity to other ACTs & Regulations
Quality Control & Inspection
Building Bye Laws :
21
Licensing & Certification of
Engineers & Architects Responsibilities of Owner And/ Or Developer and Persons of
Record (POR) is summarized in Chaper 4 of CGDCR-2017, Part I(Procedure Regulations)
POR- Engineer of Record, Developer on Record, Clerk of Workson Record,Architect on Record, Stru. Engineer on Record.....
Contains minimum qualifications & Competence Requirement forPOR
Duties & Responsibilities.....
POR can be registered through Online portalhttps://enagar.gujarat.gov.in/
POR, who is registered with Any one authority in District can workas a consultant in all authorities & Municipalities of District.
POR, who is registered with any Municipal Corporation or UDAcan work as a consultant in all Municipal corporations & Urbandevelopment Authorities of State.
22
Technical Audit & Monitoring
As per provisions of CGDCR – 2017.........
EOR Or/ And AOR – Responsible to make planning according toCGDCR-2017 & other Regulations.
SEOR – Responsible to make design of structure in accordance with I.S.codes.
SOR & COWOR – Responsible to ensure the construction should be asper plan approved by Authority & Structural Design provided by SEOR
POR has to ensure to make plan according to Regulations and toimplement construction on site as per approved plan approved byAuthority & Design by Structural Designer.
Authority makes cross check at every stage of the construction i.e. Plinth,Lintel, Slab level.
After completion of the construction authority inspect the building onsubmission of completion by POR which should be as per approved planafter satisfactory arrangements of rain water harvesting, drainage, treeplantation etc., authority issue Building Use Permission for the ApprovedBuilding.
23
Query?
Questions??
Suggestions.......
Thank You......
◦ Er. C.B.Bhatt
E-Mail :- [email protected]
(M) :- 9427289141
24