Transcript of Bio-Cascade, Inc Clean Air and Water Systems © Distributors of Clean Air Plant (CAP ©) and Clean...
Bio-Cascade, IncClean Air and Water Systems©
Distributors of Clean Air Plant (CAP©)
and Clean Water Plant (CWP©)
For Air and Water Solutions, Nutley, NJ
Air & Water Solutions History
• 1996 - Introduction of CAP Clean Air Plant for control of indoor air quality (IAQ), World’s 1st (and only) Biological IAQ Control System
• 2002 Business Achievement Award, Technology Merit Award for biological air and water cleaning systems for industry, Environmental Business Journal
Page 2 of 20
Air & Water Solutions Background
•Dr. Sam Sofer PhD, PE; Principal engineer of the bio-hygienic products offered by the company
•Nutley, New Jersey; Company headquarters, manufacturing operations and technical research center
Page 3 of 20
How CAP/CWP works
• Living organisms obtain energy by oxidation reactions.
• Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids.
Biological Oxidation
Page 4 of 20
•Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process.
•This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids.
•As contaminants come in contact with micro-organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless.
Source: www.cleanairplant.com
Biological Oxidation (continued)
Page 5 of 20
Bio-hygienics
•Contaminants and odors that are persistent travel on particulates.
•Most large particles will travel with air flow and can be vented.
•Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented.
•These particulates are electrically charged. •Their motion is controlled by electrical fields not by air flow.
•For these reasons, many odors linger even when an area is exhausted.
(bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications
Page 6 of 20
• CAP© neutralize contaminants in the air and creates an electrically neutral “clean zone.”
• Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized.
• CWP© work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized.
Bio-hygienics (continued)
Page 7 of 20
Substantial cost savings• Superior technology to
– Carbon - substantially more economical– Thermal destruction
• First bio-oxidizer designed for indoor applications • Miniaturized plants save energy and space• Single technology, single solution • Very low maintenance • Can be installed modularly to meet growing demands • Bio-hygienics offers the benefits of immobilized cell
technology in a compact treatment plant that is fast,effective and economical.
• Advances in bio-hygienics address air and water quality, nuisance odor issues and industrial waste management in a complete, economical solution for companies large and small.
• CAPs and CWPs are the only bio-systems that address air and water contaminants bio-hygienically.
Page 8 of 20
Machine Operation
• The CAP™ Machine is can be modified to fit both stationary and portable applications.
• The size of the machine is based on both area covered and amount of pollution present
• Portable applications: It is recommended the machine be in operation in the area prior to activity related to targeted pollution
Page 9 of 20
• BioOX© is the Bio-Enzyme microbial media used to consume pollution.
• Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation).
• The more pollution ,the more BioOx needed. • Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems.
Page 10 of 20
CAP™/CWP™
•Dual outlet power supply to run pump and fan.
•Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines.
•Heaters can be added for exterior applications to prevent water freeze.
•BioOx added monthly or more frequently as needed.
CAP™ requirements for normal operation
Page 11 of 20
Trash Transfer Station Applications
CAP 5000 with Rodent Intake Guards
CAP™ 5000
Page 12 of 20
•Can be made portable
•Will cover up to 3,000 sq.ft.
•10 lbs. of pollution per day
CAP™ 90
Page 13 of 20
CAP™ 600 • Covers areas over 5,000 sq.ft.
• Destroys up to 60 lbs. of pollution per day
• Interior and exterior applications
Page 14 of 20
Compare Indoor Air Cleaners
Type Cleaner Gases VOC’S Particulates Bio-Hygienics Safety
Ozone
Ionizer
UV
HEPA
(all air filters)
Carbon Canister
CAP
Technology Evaluation Table for Indoor Air Cleaners
Page 15 of 20
CAP™ Machine SpecificationsModel Equiv.
Flow Rate (cfm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
NEW CAP-50 500 5 8 oz startup
2 oz/week for 2 mos.
Thereafter 2 oz/month
12” sq x 15”
18 lbs
30 W
Up to 800 ft2 Room, office
NEW CAP-75 520 7 8 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 20”
20 lbs
30 W
Up to 1500 ft2 Small house, office
NEW CAP-80 1000 10 16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
12” sq x 24”
25 lbs
30 W
Up to 2000 ft2 Medium office, garage, shop,
salon, schoolroom
CAP-90 Industrial Model
1000 10 16 oz startup
4 oz/week for 2 mos.
Thereafter 4 oz/month
15” sq x 32”
35 lbs
40 W
Up to 3000 ft2 Office, plant, garage,
commercial & small industry
Page 16 of 20
CAP™ Machine Specifications (continued)Model Equiv.
Flow Rate (cfm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans Typical Application
CAP-600 7500 60 1 gal. startup
16 oz/week for 2 mos.
Thereafter 16 oz/month
30” dia x 48”
26” at base
200 lbs
175 W
Units designed to
handle commercial
and industrial areas
of 5000 ft2 and
larger, with heavy
pollution load
Small-medium industry, plant,
warehouse, lab, loading dock,
restaurant, bar, hotel, parking
garage
CAP-2500 12500 250 2 gal. startup
48 oz/week for 2 mos.
Thereafter 48 oz/month
36” dia x 50”
+ 12-24” fan housing
300 lbs
438 W
Industry, plant,
terminal,
indoor/outdoor,
heavy pollutionCAP-5000 19400 500 3 gal. startup
½ gal./week for 2 mos.
Thereafter 64 oz/month
52” dia x 50”
+ 12-24” fan housing
500 lbs
500 W
CAP-X Series (all models above)
All environments. Specifically designed for
extremely concentrated and
toxic air contaminants
Concentrated discharges from mixers, reactors and other similar
equipment
Page 17 of 20
CWP™ Machine SpecificationsModel Equiv.
Flow Rate
(gpm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
CWP-100 2 10 4 oz./mo.
Startup: 16 oz. Then 4 oz/week for 2 mos.
12” sq x 20”
30 lbs
Small, compact and
portable
For sinks, fish tanks, ponds. Small space applications
CWP-175 20 40 16 oz/mo.
Startup: 32 oz. Then 8 oz/week for 2 mos.
12” sq x 20”
20 lbs
30 W
Small-scale industry, industrial
wastewater, waste tank
contents, fuel-contaminated home sumps
or direct treatment of ground water
CWP-SVE 20-50 60 16 oz/mo.
Startup: 1 gal. Then 16 oz/week for 2 mos.
30” dia x 8”
100 lbs
Saves on carbon costs
For industrial applications, fish tanks,
wells, ponds, small lakes.
Page 18 of 20
CWP™ Machine Specifications (cont.)
Model Equiv. Flow Rate
(gpm)
Pollution Destruction (lbs/day)*
BioOx®
Usage
Size & Weight (US) Power
Consumption
Area Model Cleans
Typical Application
CWP-1000 50 100 24 oz./mo.
Startup: 1 gal.
Then 24 oz/week for 2 mos.
36” dia x 48”
250 lbs. Cleans large
amounts of
liquid.
Designed for
sudden
increase in
flow.
Wastewater,
chemical
waste streams,
waste tank
contents.
Large volume
streams or
surface water
runoff.
Direct
treatment of
groundwater.
CWP-2500 50-100 250 48 oz./mo.
Startup: 2 gal.
Then 48 oz/week for 2 mos.
36” dia x 50”
250 lbs.
CWP-5000 100-200
500 64 oz./mo.
Startup: 3 gal.
Then ½ gal./week for 2 mos.
52” dia x 50”
350 lbs.
CWP-25000 100-500
2500 2.5 gal./mo.
Startup: 10gal.
Then 1 gal./week for 2 mos.
72” dia x 84”
600 lbs.
Page 19 of 20
For more information
or to contact us:
www.Bio-Cascade.com
Page 20 of 20