STATE OF NEW JERSEY STATE OF NEW JERSEY DEPARTMENT OF THE TREASURY DEPARTMENT OF THE TREASURY DEPARTMENT OF ENVIRONMENTAL PROTECTION DEPARTMENT OF ENVIRONMENTAL PROTECTION BID DOCUMENTS BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT INVITATION FOR BIDS Bid Number: 06-X-37945 VOLUME 2 APPENDICES APPENDICES Date Issued: NOVEMBER 2005

Transcript of BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is...

Page 1: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

STATE OF NEW JERSEYSTATE OF NEW JERSEYDEPARTMENT OF THE TREASURYDEPARTMENT OF THE TREASURY

DEPARTMENT OF ENVIRONMENTAL PROTECTIONDEPARTMENT OF ENVIRONMENTAL PROTECTION

BID DOCUMENTSBID DOCUMENTSNJDEP EMRRGENCYSERVICES TERM CONTRACT

INVITATION FOR BIDSBid Number: 06-X-37945

VOLUME 2 –– APPENDICESAPPENDICES

Date Issued: NOVEMBER 2005

Page 2: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

APPENDIX A

SITE ENTRY - LEVEL OF PROTECTION I. INTRODUCTION

Personnel must wear protective equipment when response activities involve known or suspected atmospheric contamination, when vapors, gases, or particulars may be generated, or when direct contact with skin-affecting substances may occur. Respirators can protect lungs, gastrointestinal tract, and eyes against toxicants. Chemical-resistant clothing can protect the skin from contact with skin-destructive and absorbable chemicals. Good personal hygiene limits or prevents ingestion of material. Equipment to protect the body against contact with known anticipated chemical hazards has been divided into four categories according to the degree of protection afforded: - Level A: Should be worn when the highest level of respiratory, skin, and eye

protection is needed. - Level B: Should be selected when the highest level of respiratory protection is

needed, but a lesser level of skin protection. Level B protection is the minimum level recommended on initial site entries until the hazards have been further defined by on site studies and appropriate personnel protection utilized.

- Level C: Should be selected when the type(s) of airborne substance(s) is known, the

concentration(s) is measured, and the criteria for using air purifying respirators are met.

- Level D: Should not be worn on any site with respiratory or skin hazards. Is

primarily a work uniform providing minimal protection. The Level of Protection selected should be based primarily on: - Type(s) and measured concentration(s) of the chemical substance(s) in the ambient

atmosphere and its toxicity. - Potential or measured exposure to substances in air, splashes of liquids, or other direct

contact with material due to work being performed. In situations where the type(s) of chemical(s), concentration(s), and possibilities of contact are not known, the appropriate Level of Protection must be selected based on professional experience and judgment until the hazards can be better characterized.

1

Page 3: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

While personnel protective equipment reduces the potential for contact with harmful substances, ensuring the health and safety of response personnel requires, in addition, safe work practices, decontamination, site entry protocols, and other safety considerations. Together, these protocols establish a combined approach for reducing potential harm to workers.

II. LEVELS OF PROTECTION A. Level A Protection 1. Personnel protective equipment.

- Pressure-demand, self-contained breathing apparatus, approved by the Mine Safety and Health Administrative (MSHA) and National Institute of Occupational Safety and Health (NIOSH).

- Fully encapsulating chemical-resistant suit - Coveralls* - Long cotton underwear* - Gloves (inner), chemical-resistant - Gloves (outer), chemical-resistant - Boots, chemical-resistant, steel toe and shank. (Depending on suit construction,

worn over or under suit boot) - Hard hat* (under suit) - Disposable protective suit, gloves, and boots* (Worn over fully encapsulating

suit) - 2-Way radio communications (intrinsically safe)

* optional, or dependent on conditions 2. Criteria for selection. Meeting of any of these criteria warrants use of Level A Protection:

- The chemical substance(s) has been identified and required the highest level of

protection for skin, eyes, and the respiratory system based on:

--measured (or potential for) high concentration(s) of atmospheric vapors, gases, or particulates

--site operations and work functions involving high potential for splash,

immersion, or exposure to unexpected vapors, gases or particulates

2

Page 4: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

- Extremely hazardous substances (for example: dioxin, cyanide compounds, concentrated pesticides, Department of Transportation Poison “A” materials, suspected carcinogens, and infectious substances) are known or suspected to be present, and skin contact is possible.

- The potential exists for contact with substances that are readily absorbed

through, damage, or destroy skin. - Operations must be conducted in confined, poorly ventilated areas until the

absence of hazards requiring Level A protection is demonstrated. - Total atmospheric concentrations of unidentified gases or vapors, as indicated

with an Flame Ionization Detector (FID), and or, Photo-Ionization Detector (PID) air monitoring instrument (s), range from 500 ppm to 1,000 ppm, or know substances are above NIOSH recommended levels that are Immediately Dangerous to Life and Health (IDLH).

3. Guidance on selection criteria.

The fully encapsulating suit provides the highest degree of protection to skin, eyes, and respiratory system if the suit material is resistant to the chemical(s) of concern during the time the suit is worn and/or at the measured or anticipated concentrations. While Level A provides maximum protection, the suit material may be rapidly permeated and penetrated by certain chemicals from extremely high air concentrations, splashes, or immersion of boots or gloves in concentrated liquids or sludges. These limitations should be recognized when specifying the type of chemical-resistant garment. Whenever possible, the suit material should be matched with the substance it is used to protect against. The use of Level A protection and other chemical-resistant clothing requires evaluating the problems of physical stress, in particular heat stress associated with the wearing of impermeable protective clothing. Response personnel must be carefully monitored for physical tolerance and recovery. Protective equipment being heavy and cumbersome, decreases dexterity agility, visual acuity, etc., and so increases the probability of accidents. This probability of accidents should be considered when selecting a Level of Protection. Many toxic substances are difficult to detect or measure in the field. When such substances (especially those readily absorbed by or destructive to the skin) are known or suspected to be present and personnel contact is unavoidable, Level A protection should be worn until more accurate information can be obtained.

B. Level B Protection

3

Page 5: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

1. Personal protective equipment

- Pressure-demand, self-contained breathing apparatus (MSHA/NIOSH approved) - Chemical-resistant clothing (overalls and long-sleeved jacket; overalls;

hooded, one or two-piece chemical-splash suit; disposable chemical-resistant coveralls)

- Coveralls* - Gloves (outer), chemical-resistant - Gloves (inner), chemical-resistant - Boots (inner), chemical-resistant - Boots (outer), chemical-resistant - Hard hat (face shield)* - Two-way radio communication (intrinsically safe)

* optional, or dependent on conditions

2. Criteria for selection Meeting any one of these criteria warrants use of Level B protection:

- The type(s) and atmospheric concentration(s) of toxic substances have been identified and required the highest level of respiratory protection, but a lower level of skin and eye protection. These would be atmospheres:

-- with concentrations Immediately Dangerous to Life and Health (IDLH) or -- exceeding limits of protection afforded by a full-face, air-purifying mask or -- containing substances for which air-purifying canisters do not exist or have low removal efficiency or -- containing substances requiring air-supplied equipment, but substances and/or concentrations do not present a serious skin hazard. - The atmosphere contains less than 19.5% oxygen.

4

Page 6: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

- Site operations make it highly unlikely that the small, unprotected area of the

head and neck will be contacted by splashes of extremely hazardous substances.

- Total atmospheric concentrations on unidentified vapors or gases, as indicated

by an Flame Ionization Detector (FID), and or, Photo-Ionization Detector (PID) air monitoring instrument (s), range from 5 ppm to 500 ppm and vapors are not suspected of containing high levels of chemicals toxic to skin.

3. Guidance on selection criteria

Level B equipment provides a high level of protection to the respiratory tract, but

a somewhat lower level of protection to skin. The chemical-resistant clothing required in Level B is available in a wide variety of styles, materials, construction detail, permeability, etc. These factors all affect the degree of protection afforded. Therefore, a specialist should select the most effective chemical-resistant clothing (and fully encapsulating suit) based on the known or anticipated hazards and/or job function.

Generally, if a self-contained breathing apparatus is required, Level B clothing

rather than a Level A fully encapsulating suit is selected, based on the protection needed against known or anticipated substances affecting the skin. Level B skin protection is selected by:

- Comparing the concentrations of known or identified substances in air with skin

toxicity data. - Determining the presence of substances that are destructive to and/or readily

absorbed through the skin by liquid splashes, unexpected high levels of gases or particulates or other means of direct contact.

- Assessing the effect of the substances (at its measured air concentrations or splash

potential) on the small area of the head and neck unprotected by chemical-resistant clothing.

For initial site entry and reconnaissance at an open site, approaching whenever possible from the upwind direction, Level B protection (with good quality, hooded, chemical-resistant clothing) should protect response personnel, providing the conditions described in selecting Level A are known or judged to be absent. For continuous operations, the aforementioned criteria must be evaluated. At 500 ppm total vapors/gases, upgrading to Level A protection may be advisable. A major factor for re-evaluation is the presence of vapors, gases, particulates requiring a higher degree of skin protection.

5

Page 7: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

C. Level C Protection

1. Personal protective equipment - Full-face, air-purifying, canister-equipped respirator (MSHA/NIOSH approved) - Chemical-resistant clothing (coveralls; hooded, two-piece chemical splash suit; chemical-resistant hood and apron; disposable chemical- resistant coveralls)

- Coveralls* - Gloves (outer), chemical-resistant - Gloves (inner), chemical-resistant* - Boots (inner), chemical-resistant, steel toe and shank* - Boots (outer), chemical-resistant, (disposable)* - Hard hat (face shield)* - Escape Mask - Two-way radio communications (intrinsically safe) -

* optional, or dependent on conditions 2. Criteria for selection Meeting all of these criteria permits use Level C protection:

- Oxygen content of the atmospheric is at least 19.5% by volume.

- Measured air concentrations of identified substances will be reduced by the respirator to, at or below the substance’s exposure limit, and the concentration is within the service limit of the canister.

- Atmospheric contaminant concentrations do not exceed IDLH levels. - Atmospheric contaminants, liquid splashes, or other direct contact will not

adversely affect the small area of skin left unprotected by chemical-resistant clothing.

- Job functions have been determined not to require self-contained breathing

apparatus.

- Total unidentified vapor readings register between background and 5 ppm above background as indicated by an Flame Ionization Detector (FID), and or, Photo-Ionization Detector (PID) air monitoring instrument (s), or, substances present are know and have established Permissible Exposure Limits (PELs), or Threshold Limit Values (TLVs) in order determine Maximum Use Concentrations of filter cartridges.

6

Page 8: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

- Air will be monitored periodically.

3. Guidance on selection criteria

Level C protection is distinguished from Level B by the equipment used to protect the respiratory system, assuming the same type of chemical-resistant clothing is used. The main selection criterion for Level C is that conditions permit wearing air-purifying devices.

The air-purifying device must be a full-face mask (MSHA/NIOSH approved)

equipped with a canister suspended from the chain or on a harness. Canisters must be able to remove the substances encountered. Quarter-or-half-masks or cheek-cartridge full-face masks should be used only with the approval of a qualified individual.

In addition, a full-face, air-purifying mask can be used only if: - Substance(s) is identified and its concentration(s) measured. - Substance(s) has adequate warning properties. - Individual passes a qualitative fit-test for the mask.

- Appropriate cartridge/canister is used, and its service limit concentration is not exceeded.

An air monitoring program is part of all response operations when atmospheric contamination is known or suspected. It is particularly important that the air be monitored thoroughly when personnel are wearing air-purifying respirators (Level C). Continual surveillance using direct-reading instruments and air sampling is needed to detect any changes in air quality necessitating a higher level of respiratory protection. Total unidentified vapor/gas concentrations of 5 ppm above background require Level B protection. Only a qualified individual should select Level C (air purifying respirators) protection for continual use in an unidentified vapor/gas concentration of background to 5 ppm above background.

D. Level D Protection

1. Personal protective equipment - Coveralls* - Gloves* - Boots/shoes, leather or chemical-resistant, steel toe and shank

7

Page 9: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

- Boots (outer), chemical-resistant (disposable)* - Safety glasses or chemical splash goggles* - Hard Hat (face shield)* - Escape Mask*

* optional, or depending on conditions

2. Criteria for selection Meeting any of these criteria allows use of Level D protection.

- No hazardous air pollutants have been measured or known contaminant levels are below established PELs and TLVs.

- Work functions preclude splashes, immersion, or potential for unexpected

inhalation of any chemicals. 3. Guidance on selection criteria Level D protection is primarily a work uniform. It can be worn in areas where: 1) only boots can be contaminated, or 2) there are no inhalable toxic substances.

8

Page 10: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

HEALTH, SAFETY NON – EMERGENCY RESPONSE MINIMUM REQUIREMENTS

INDEX 1.0 GENERAL 2.0 REQUIREMENTS 1.0 GENERAL 1.1 DESCRIPTION OF SCOPE A. Hazardous Waste Site Prior to being engaged for any work to be performed at any hazardous waste site as

defined within the meaning of 29 CFR 1910.120, the Contractor shall submit a Health and Safety Plan to the New Jersey Department of Environmental Protection (NJDEP). The HASP must receive NJDEP approval before a notice to proceed with any site work will be granted.

B. Minimum Requirements This document describes the minimum safety, health, and emergency response

requirements for remedial activities at the site. The responsibility for development, implementation, and enforcement of the HASP lies with the Contractor and its health and safety personnel. The HASP developed by the Contractor shall include programs for accident prevention, personnel protection, medical surveillance, training, special and permit operations, excavation and trenching, spill containment, emergency responses and contingency planning, and air monitoring.

C. Compliance and Termination Safety and health requirements shall conform to 29 CFR 1910.120, other federal and

state codes and statutes as identified by the text of this document. Controls and procedures specified herein and by the HASP may be terminated only when a Certified Industrial Hygienist, or other qualified person, determines that hazards have been eliminated. Such termination shall be effective only if approved in writing by the NJDEP.

1

Page 11: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

1.2 SITE DESCRIPTION A. Specific Location The site's description includes: Street address, Lot #, Block # and all other locations

where work is to be conducted for this contract. B. Supplements and Additions The site may be described in supplementary sections. Additional details provided should

be referenced and presented in listed subsections. C. Site History A short history of the site prior to the contracted operations should be presented,

indicating industrial/hazardous activities. 1.3 SUBMITTALS A. Contractor Submissions to State Department of Environmental Protection 1. The Contractor shall submit three (3) copies of a HASP to the NJDEP and one (1)

copy to the specified lead representative of the department for this contract. 2. The Contractor shall submit to the department four (4) copies of analytical results

from any area or personnel samples that are specified in the subsections. 3. The Contractor shall submit to the department on a weekly schedule, four (4) copies

of the daily air monitoring log as specified by the NJDEP Office of Site Safety and Health (OSSH).

B. Health and Safety Plan (HASP) Approval 1. Review and approval of the HASP shall be the responsibility of the (OSSH). 2. The OSSH shall provide back to the Contractor, through the NJDEP site/construction

manager a written evaluation of the submitted HASP. Evaluation of the HASP shall be performed by comparison to the minimum requirements presented in this

2

Page 12: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

document and applicable state and federal statutes. 2.0 MINIMUM REQUIREMENTS 2.1 ORGANIZATIONAL RESPONSIBILITIES A. Key Personnel and Organizational Chart. The Contractor must provide, at a minimum, an organizational chart and resumes of key

personnel involved in all phases of the operations on site. Also, the contractor must submit the names of other personnel needed for hazardous waste site operations and emergency response, indicating their functions and responsibilities. This chart must include Senior-Level Management, Project Manager, Health and Safety Officer (HSO), Field Supervisor, and on-site Foreman Personnel, at a minimum.

B. Site Health and Safety Officer (HSO) The Contractor must utilize a qualified individual (e.g., an industrial hygienist, safety

engineer, etc.) to function as the Site HSO for the project. That individual must be responsible to the Contractor and have the authority and knowledge necessary to implement the site HASP and verify compliance with applicable safety and health requirements.

1. At a minimum, the HSO shall have the following responsibilities and authority to

perform the following functions: a. Be present at all times during site operations. b. Have the authority to enforce the HASP and stop operations if safety and health

of personnel may be jeopardized. c. Effect evacuation of the site or work area if necessary. d. Evaluate monitoring data to make field decisions regarding safety and health. C. The HSO must meet the following minimum educational and experience qualifications

in matters of health and safety: 1. Possess a sound working knowledge of State and Federal occupational safety and

health regulations.

3

Page 13: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

2. Have formal professional development training in occupational safety and health.

Initial 40 Hour (or 24 hour) HAZWOPER or any other basic training necessary for general work eligibility will not satisfy this requirement.

3. Satisfy either 3a or 3b a. Have a minimum of five (5) years experience in the environmental and health and

safety services field, chemical industry, or chemical waste disposal industry, more than 50% of which must be in the area of industrial hygiene and/or environmental safety related to the site operations.

or b. Have a bachelor of science degree in biology, chemistry, engineering, industrial

hygiene or other related natural or physical science and one (1) years experience in the environmental and health and safety services field, chemical industry, or chemical waste disposal industry, more than 50% of which must be in the area of industrial hygiene and/or environmental safety related to the site operations.

NOTE: A graduate degree in occupational safety and health can be substituted for 3a or 3b. 2.2 RISK OR HAZARD ANALYSIS A. Health and Safety Evaluation The Contractor shall perform and provide a hazard assessment for each location and the

tasks to be performed. B. Best Information available The assessment shall be based upon the best information available regarding the

contaminants and conditions present at the site as well as the practices, tools and other equipment to be applied in the operation and shall include but not be limited to the following:

1. A preliminary evaluation of the site's characteristics performed prior to the initial site

survey 2. An evaluation of the known or suspected contaminants and conditions that may pose

inhalation, skin absorption/contact, exposure or ingestion hazards.

4

Page 14: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

3. Material Safety Data Sheets (MSDS) shall be provided on site for any chemicals

known to be present which workers may be exposed to during site normal operations or in a foreseeable emergency.

4. An evaluation of known or potential safety hazards associated with each task 5. An overview of the following information: a. Size and location of the site b. Description of the operation and tasks to be performed c. Approximate duration of each operation and task d. Site topography, accessibility and special features (e.g., structures, tanks) e. Known or suspected pathways of contaminant dispersion pertinent to the

operations and tasks performed f. Safety and health hazards expected on the site g. Status and capabilities of emergency response teams that shall provide assistance

during site emergencies, including those providing medical treatment and transport of any contaminated injured persons.

2.3 EMPLOYEE TRAINING A. Training Requirements for On-Site Personnel 1. Pursuant to 29 CFR 1910.120, et al, all Contractor and subcontractor employees for

on-site activities must have met one of the following requirements prior to the start of operations at the site:

a. General site workers (such as equipment operators, general laborers, and

supervisory personnel) engaged in hazardous substance removal, or other activities that expose or potentially expose workers to hazardous substances and health hazards, shall receive a minimum of 40 hours of instruction off the site, and a minimum of three (3) days actual field experience under the direct supervision of a trained, experienced supervisor.

5

Page 15: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

b. Workers on site only occasionally for a specific limited task (such as, but not limited to, groundwater monitoring, land surveying, or geophysical surveying) and who are unlikely to be exposed over permissible exposure limits and published exposure limits shall receive a minimum of 24 hours of instruction off the site, and a minimum of one day actual field Experience under the direct supervision of a trained, experienced supervisor.

c. Workers regularly on site, who work in areas that have been monitored and are

fully characterized indicating that exposures are under permissible exposure limits and published exposure limits where respirators are not necessary, and the characterization indicates that there are no health hazards or the possibility of an emergency developing, shall receive a minimum of 24 hours of instruction off the site and a minimum of one day actual field experience under the direct supervision of a trained, experienced supervisor.

d. Workers with 24 hours of training who are covered by paragraphs b. and c. of

this section, and who become general site workers or who are required to wear respirators, shall have the additional 16 hours and two (2) days of training necessary to total the training specified in paragraph a.

e. In addition, an annual eight (8) hour minimum refresher course after the initial

training shall be provided to all field (site) personnel in order to continue on site employment eligibility.

2. On-site management and supervisors directly responsible for or who supervise

employees engaged in site operations, including the on-site HSO, shall have also received eight (8) hours additional training in managing such site operations prior to the start of site activities as stipulated in 29 CFR 1910.120.

3. Employees who have been designated as responsible for responding to on-site

emergencies shall have received additional training in how to respond to such expected emergencies prior to the start of site operations as stipulated in 29 CFR 1910.120.

4. Employees who have not received the required training prior to the start of site

operations are not to engage in site operations until such training has been completed.

B. Employee Training Program The Contractor shall include in the HASP a summary of the hazardous materials safety

and health training program and a list of elements and topics covered.

6

Page 16: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

C. Program Certification The Contractor shall provide written certification statement of completed training and/or

acquired experience for all employees designated to engage in on-site activities. Such certification shall be endorsed by a member of top-level management, a corporate officer, or the health and safety program manager and shall be incorporated into the HASP.

D. Site Specific Training and Pre-entry Briefings The Contractor shall provide site specific training and perform daily safety briefings that

will provide an awareness of planned operations, the site-specific HASP, the form and warning properties of potential hazards, work zones, locations of emergency/safety equipment, local emergency response procedures and any changes in site characteristics, levels of protection, communications, decontamination procedures, emergency facilities and signals, and evacuation procedures.

2.4 PERSONNEL PROTECTION A. Engineering and Work Practice Controls. The Contractor must consider the need to apply engineering and/or work practice

controls as a means of protecting personnel in the performance of site-specific tasks. When practicable, engineering controls shall be implemented to reduce and maintain employee exposures to or below safe levels for those tasks demonstrating known or suspected hazards. Work practice controls shall next be applied when engineering controls are impractical and shall be incorporated as site-specific standard operating procedures (SOPs) for personnel precautions and routine operations.

B. Personnel Protective Equipment (PPE) and Levels of Protection 1. The Contractor shall use personnel protective equipment (PPE) only when

engineering and/or work practice controls have been deemed impractical or insufficient to protect employees during site operations.

2. The Contractor shall select PPE based on an evaluation of performance

characteristics, site-specific tasks, and known or suspected hazards and shall assemble the PPE into Levels of Protection (LOP) or ensembles appropriate for the site.

7

Page 17: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

3. The Contractor shall include in the HASP a list of components for each protective ensemble, the LOP selected for each task, the rationale for each task-specific selection, and any contaminant action levels to be followed in LOP decision making. This information can be presented in a block-type chart with specific references to fabric, Level of Protection, permeation, etc., in a text.

These specific tasks requiring identification of protective clothing ensembles shall

include but not be limited to: a. Existing Debris and Waste Removal b. Recovery, Injection, and Monitoring Well Construction c. Excavation d. Contaminated Soil Removal e. Sampling and Monitoring f. Dewatering g. Erosion and Sediment Control h. Operating specialized equipment, containers i. Confined Space and Hazardous Area Entry 4. If the Contractor's HASP provides for respiratory protection, the Contractor shall

include a description of the respiratory protection program and the method of respirator fit testing employed.

5. The Contractor shall use only NIOSH/MSHA approved respiratory protective

equipment. Any other PPE selected shall be in conformance with appropriate ANSI standards for that equipment.

6. The Contractor shall establish a PPE program addressing the following elements: a. Site hazards b. PPE selection c. PPE use and limitations

8

Page 18: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

d. Duration of site operations e. PPE maintenance and storage f. PPE decontamination and NJDEP approved disposal g. PPE training and proper fit h. Donning and doffing procedures i. PPE inspection prior to, during and after use j. Evaluation of program effectiveness l. Heat stress and temperature limitations 2.5 MEDICAL SURVEILLANCE A. Medical Surveillance Program 1. The Contractor shall have an established and implemented medical surveillance

program (MSP) for employees engaged in on-site operations, if any of the following 29 CFR 1910.120(b) criteria are met:

a. All employees who are, or may be, exposed to hazardous substances, or health

hazards, at or above the permissible exposure limits, or if there is no permissible exposure limit, above the published exposure levels for these substances, without regard to the use of respirators, for 30 days or more a year

b. All employees who wear a respirator for 30 days or more a year or as required by

29 CFR 1910.134/139. c. All employees who are injured due to overexposure from an emergency incident

involving hazardous substances or health hazards d. Members of HAZMAT teams 2. The MSP program shall include physical examinations administered or supervised

by a board-certified physician knowledgeable in internal or occupational medicine. The Contractor shall include the name and business address of the administering

9

Page 19: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

physician in the HASP. 3. The Contractor shall include a written description of the components of both the

MSP program and the physical examination in the HASP and whether the examination is administered or supervised by the physician.

4. The Contractor shall address the need for personnel exposure monitoring and post-

exposure medical screening in the HASP and include a description of those provisions.

5. The contractor shall provide to the employee, the physician’s written opinion. The

written opinion shall contain the attending physician’s opinion as whether the employee has any detectable medical condition which would place the employee at increased risk of material impairment of the employee’s health from work in hazardous waste operations or emergency response, or from respirator use.

6. The physician’s written opinion shall contain the physician’s recommended

limitations upon the employee’s assigned work and the results of the medical examination and tests

7. The contractor shall provide a statement that the employee has been informed by the

physician of the results of the medical examination and any medical conditions which require further examination or treatment.

8. The physician’s written opinion obtained by the employer shall not reveal specific

findings or diagnoses unrelated to occupational exposures.

B. Medical Records Retention The Contractor shall retain all medical records and personnel exposure monitoring data

for 30 years as described in Subpart C of 29 CFR 1910.120. C. Fitness Certification The Contractor shall provide written certification of the medical fitness for work of all

employees designated to engage in on-site operations prior to the start of those operations. Such certification shall be endorsed by a member of senior management, a corporate officer, or the health and safety program manager and shall be incorporated into the site HASP.

D. Heat and Cold Stress Monitoring

10

Page 20: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

As dictated by seasonal conditions, the Contractor shall implement an employee heat, and/or, cold stress monitoring program during site operations and shall incorporate the program into the site HASP. The program shall include employee awareness of the signs and symptoms of heat and/or cold stress, preventive measures, and employee and/or environmental parameters that will be measured. The Contractor shall maintain a daily heat and/or cold stress log on all employees wearing protective ensembles on-site and shall describe the log in the site HASP.

2.6 AIR SURVEILLANCE A. Site Specific Monitoring The Contractor shall establish and implement a site-specific air monitoring program to

identify areas of elevated airborne contaminant concentrations and to determine the level of the concentrations relative to background. The Contractor shall provide the personnel, instruments, and materials necessary to perform such air monitoring and identify the individual responsible for administering the program. The program shall be included in the HASP.

1. The Contractor must incorporate the following information into the air monitoring

program: a. Type, make, and model of instrument(s) selected for use b. All instrument settings for each instrument used

c. Method of instrument calibration, including calibrant and sample calibration data sheet

d. Method of field checks, including field check materials and record of checks

e. Manner and frequency of calibration and pre and post (or greater) field checks 2. The Contractor must present the frequency of air measurements and the tasks or

locations to be monitored. B. Area and Personnel Air Sampling

11

Page 21: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

1. The Contractor shall examine and report to the NJDEP's satisfaction the need, or lack

thereof, to develop and implement area and personnel air sampling programs during the project, based upon adequate initial Area and Personnel Air Sampling episodes, and shall include any resultant air sampling program in the site HASP.

2. Special considerations shall be given to intrusive or high-risk tasks and the potential

for exposure to those performing such tasks. 3. The Contractor shall provide all necessary sampling devices, pumps, collection

media, and support equipment to perform the sampling per the program. The sampling devices and pumps must bear all approvals necessary for use in combustible or flammable atmospheres.

4. The sampling devices, pumps, collection media, and any necessary support

equipment shall be appropriately assembled into a sampling train, and each resultant sampling train shall be flow calibrated as a complete system before and after each day's use against a primary standard.

5. The Contractor shall maintain a daily sampling record as part of the air sampling

program. The record must include, as a minimum, the following: a. Collection date b. Sample identification number c. Location and/or task monitored d. Wind speed and direction during each sample collection period e. Duration of each sample collected, including the start and stop times of each

sample f. Ambient temperature and humidity of sampling period g. Pre- and post sampling train flow rate checks h. Instrument readings, calibration and field checks i. Any pertinent comments 6. The laboratory selected for sample analysis must be accredited by the AIHA for the

12

Page 22: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

analysis required. Sampling and analytical methods of first NIOSH, then OSHA, must be used preferentially when such methods are available for the samples collected and all appropriate QA and QC provisions regarding sample collection, transport, and holding times must be followed. Sampling and health and safety protocols are presented in the NJDEP's most current Field Sampling Procedures Manual, (May 1992).

C. Records Retention and Data Reporting 1. The Contractor shall retain all personnel exposure sampling results and monitoring

data in accordance with the requirements set forth in OSHA, Subpart C of 29 CFR 1910.120. The Contractor shall follow all other pertinent provisions of that regulation.

2. The Contractor shall submit, in writing, the analytical results from any area and

personnel samples collected within 30 working days of the collection of each sample. Sample flow rates in liters per minute (lpm) and sampling periods in minutes for each sample collected must be reported with the analytical results. Sample locations or tasks and identification numbers shall also be reported.

3. The Contractor shall maintain a daily air monitoring log and include, as a minimum,

the following information: a. Monitoring date b. Location and/or task monitored c. Wind speed, direction, ambient temperature, and humidity d. Instruments used including make and model and all instrument settings e. Instrument readings f. Pertinent comments or information g. Results of instrument calibration checks, including date and time of each check,

the calibration agent used, and its concentration, for each instrument employed. 4. The Contractor shall report verbally all data resulting from daily air monitoring to the

NJDEP representative, at a minimum, at the end of the work period. If at any time the instrumentation indicates an adverse change in conditions, the HSO must notify the NJDEP representative immediately and follow up this reporting in writing by the

13

Page 23: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

close of business on that day. 5. The Contractor shall furnish copies of the daily air monitoring log to the NJDEP

representative at a minimum, weekly, unless otherwise noted or arranged. 2.7 SITE CONTROL A. Routine Requirements For ongoing operations, the Contractor and/or its designee will be required to meet with

the on-site NJDEP representative, when present, prior to the start of the day's activities to prepare all the necessary paperwork and outline the day's activities. The Contractor shall also meet at the completion of the day's activities to discuss the work performed.

B. Control of Work Zones 1. The Contractor shall be responsible for conducting operations at the site in such a

controlled fashion as to reduce the possibility of contact with any contaminants present and to prevent the removal of contaminants by personnel or equipment leaving the site. The Contractor shall delineate work zones in which specific operations or tasks will occur and shall institute specific site entry and decontamination procedures at designated control points.

2. Three (3) work zones shall be established to perform this work: an exclusion

(contaminated) zone, a contamination reduction zone and a support (clean) zone. A map or diagram showing the specific work zones and a description of the site control plan shall be included in the HASP. The work zone boundaries shall be revised as the work of removing hazardous materials proceeds, so as to reflect the reduced area containing hazardous materials. The revised map or diagram shall be inserted in the HASP and provided to the NJDEP representative upon adoption of each revision. The Contractor shall include any SOPs pertaining to site control in the HASP and shall incorporate plans for routine and emergency communications appropriate for the site and project.

3. The Contractor shall keep a daily site control log. The log shall include: a. Personnel visiting the site b. Affiliation c. Date

14

Page 24: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

d. Arrival time e. Departure time f. Purpose of visit and locations visited 4. The Contractor shall provide the NJDEP lead representative with a list of all

Contractor and subcontractor personnel who are authorized to enter the site prior to the start of operations, updating the list as necessary. Authorized NJDEP personnel shall have unlimited access to the site. The Contractor shall be responsible to exclude all unauthorized entrants from the site.

2.8 DECONTAMINATION A. Personnel and Equipment Requirements All contaminated personnel and equipment exiting the exclusion zone must be

decontaminated prior to entering the support zone. This decontamination must be performed in order to prevent contamination from being transferred into clean areas and contaminating or exposing unprotected personnel.

1. The Contractor shall develop and implement personnel and equipment

decontamination procedures appropriate for the site and shall include those procedures into the site HASP. The procedures shall include the necessary equipment and number of steps to achieve the objective, provisions for any personnel protection, and a diagram outlining the steps or stations in the procedures.

2. The procedures must ensure adequate containment and removal of any

decontamination solutions and spent disposable protective apparel. 3. Provisions shall be made to facilitate personal hygiene at breaks and following daily

operations. Where decontamination procedures indicate shower usage and change rooms away from the exclusion zone, they shall meet the requirements of 29 CFR 1910.141 and 1926.51.

2.9 SITE STANDARD OPERATING PROCEDURES The Contractor shall be responsible for developing and implementing all necessary SOPs for

safe and healthful site operations. Such SOPs shall be incorporated into the site HASP. A

15

Page 25: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

copy of these SOPs and the HASP are to be on site at all times. 2.10 CONTINGENCY PLANNING A. Emergency Response Plan (ERP). The Contractor shall develop and implement an Emergency Response Plan, (ERP) to

handle anticipated on-site emergencies prior to the start of site operations. B. Plan Up-Dates The ERP shall be incorporated into the site HASP as a separate section of that document

and shall be periodically reviewed and, as necessary, amended to keep it current with new or changing site conditions or information.

1. The ERP shall address, as a minimum, the following: a. Preplanning of site operations to prevent emergencies b. Personnel roles and lines of authority c. Key personnel at the site authorized and responsible for implementing the plan d. Emergency recognition and control measures e. Evacuation routes and procedures, and the frequency of emergency drills f. Safe distances and places of refuge g. Emergency security and site control measures h. Decontamination measures not previously listed in the HASP and specific for all

anticipated emergencies. i. Emergency medical treatment and first aid j. Emergency alerting and response procedures k. Site communications l. Site diagrams showing general layout, work zones, and prevailing weather

16

Page 26: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

conditions m. Procedures for reporting incidents to pertinent local, state, and Federal agencies n. A list of emergency telephone contacts including the name, location, telephone

number, written directions and a route map to the nearest medical facility that will provide emergency medical services.

o. Measures to review and follow up on site responses p. Emergency and personal protective equipment kept at the site for emergencies,

with an equipment list and a drawing indicating their on site location. 2. Prior to start up of site operations, the contractor shall attend any and all meetings

necessary with local officials and/or those responsible for local emergency management and public safety for the purpose of coordinating the site specific ERP with any emergency response efforts that would be performed by such agencies. These agencies include but are not limited to:

a. Fire, b. Ambulance, c. Police, d. Local/County health officials C. Special First Aid/CPR Training The Contractor shall ensure that at least one person holding up-to-date certifications

(American Red Cross or equivalent) in basic first aid and CPR is present at the site during all site operations. A photocopy of the current certifications must be included in the HASP.

D. Verification of Medical Facility Preparedness The contractor shall contact the local medical facility selected for inclusion into the ERP

to ensure that said facility is willing and is capable of providing that medical support necessary to satisfy those anticipated hazards and emergencies detailed in the ERP. Material Safety Data Sheets (MSDS), product information or any technical information on hazard, exposure and treatment of anticipated/known hazards should be provided by the Contractor to the medical facility. Written verification of such contact and

17

Page 27: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

agreement of medical services must be detailed in the ERP to include the name and title of individual contacted and shall be provided to the NJDEP prior to start of site operations.

E. Accident and Exposure Reports 1. The Contractor shall notify the NJDEP representative of all on-site accidents at the

time of occurrence and follow up in writing within 24 hours. This notification shall include, but not be limited to, the date, time and identity of individual(s) involved in the accident, the nature of the accident, the actions taken to treat the victim(s), and the steps taken to prevent recurrence.

2. The Contractor shall notify the NJDEP representative of all person(s) exposed at the

time of occurrence and follow up in writing within 24 hours. This notification shall include, but not be limited to, the date, time, and identity of individual(s) involved in the exposure, the nature of the exposure episode, what the individual(s) were exposed to, the personnel protective equipment worn during the exposure, and the steps taken to prevent recurrence.

3. The Contractor shall notify the NJDEP immediately of any incident/accident that

results in death or severe injury to personnel, of any fire or explosion or any incident that results in public disruption, media attention or closure of a roadway. After hours notification of such events shall be addressed to the NJDEP's 24 hour Action Line (609) 292-7171.

2.11 CONFINED SPACE OPERATIONS If no confined space entry is to be made, then a statement indicating such is sufficient for this

section, however, all confined spaces must be identified in the HASP. A. Standard Operating Procedures for Confined Spaces Should site operations include activities within confined spaces, the Contractor shall

develop and implement a confined space entry program and SOPs and shall incorporate them into the HASP pursuant to 29 CFR 1910.146. If the confined space entry meets the OSHA definition of a Permit Required Confined Space Entry, then a section addressing such entries shall be included in the HASP.

B. Entry Permit System 1. The contractor shall develop and implement an Entry Permit System to ensure that

18

Page 28: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

the following are addressed and complied with: a. Identification of all confined spaces to all employees b. Identification of hazards in the confined space c. Training program d. A system of monitoring for atmospheric hazards e. A system of calibration of monitoring equipment f. A system of barricades, to prevent unauthorized entry h. A system of identifying authorized entrants, attendants, rescuers and those

authorized to sign the entry permit i. A procedure for emergency evacuation j. Emergency rescue procedures k. Procedures to test the program to ensure effectiveness 2. Pre-entry briefings shall be held prior to initiating any confined space entries and at

other times as necessary to ensure that employees are aware of the HASP provisions governing such activities and that they are being followed. The completed permit shall be made available at the time of entry to all authorized entrants, by posting it at the point of entry or by any other equally effective means, for assurance that the pre-entry preparations have been completed.

C. Inspection and Effectiveness of SOP verification Inspections shall be conducted by the HSO or, in the absence of that individual, another

qualified individual acting on behalf of the HSO as necessary to determine the effectiveness of the confined space SOP with regard to those confined spaces identified on site. Any deficiencies in effectiveness shall be corrected by the Contractor.

D. Atmospheric Monitoring for Safe Entry The Contractor shall ensure that the HSO or, in the absence of that individual, another

qualified individual acting on behalf of the HSO, shall test the atmosphere of the confined space prior to entry and during entry to ensure that all measures necessary to

19

Page 29: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

protect the health and safety of employees entering have been taken. Monitoring shall be appropriate for the contaminant(s) that are known or suspected of being present in the space.

E. Emergency Equipment and Rescue Services The Contractor shall provide appropriate protective and entry equipment for all entrant

personnel necessary for the Permit Required entry. On site rescue personnel must be present or off site rescue must be able to respond to the site within 3 minutes of notification. Equipment necessary for a rescue must be identified and present at the point of entry.

F. Training of Entrants, Attendants and Rescuers The Contractor shall comply with the Federal OSHA training requirements for all

personnel involved in confined space entry. A training program must be administered to all personnel involved in confined space entry before entrance can be initiated. Rescue teams shall practice at least annually at the confined space or at representative openings having the same size, configuration and accessibility as the confined space from which an actual rescue would be performed. A record of training and authorized personnel shall be kept on-site and listed in the HASP.

2.12 SPILL CONTAINMENT A. Containment Program 1. The contractor shall establish and implement a written spill containment program to

handle the possibility of a spill or leakage of drummed or containerized hazardous materials involving any of the following activities:

a. Transfer b. Transport c. Disposal d. Excavation 2. The contractor shall identify the following on site and off site personnel and

equipment or services necessary to isolate, contain and mitigate the spill:

20

Page 30: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

a. Clean up contractor or personnel b. Estimate of response time of off site contractors c. Spill containment procedures (Diking, Overpack, etc.) d. Special safety precautions (fire, corrosive, radioactivity, etc.) e. Equipment and supplies on hand at site or readily available to respond to contain

and clean up the spill 2.13 SPECIAL AND PERMIT OPERATIONS A. Excavations and Trenching 1. If no trenching or excavation is to be performed on site during site operations, then a

statement indicating such is sufficient for this section. 2. All excavation work shall comply with 29 CFR 1926, Subpart P and other state and

federal regulations governing excavations and trenching. The need to perform any excavations or trenching as part of the site operations must be described in the HASP.

3. The methods of preparing the trench or excavation must be detailed to include

descriptions of sloping, shoring and guarding. 4. Proper spacing of equipment, use of barriers, means of exit, placing of machinery

and spoils must be observed. 5. Personnel working around and in trenches and excavations must be trained in such

operations to assure knowledge of hazards, safe operations and procedures to be followed in the event of an emergency.

6. Avoidance of overhead electric lines, underground utilities and storage structures,

and service passageways must be addressed by including drawings, measurements and descriptions in the HASP. All pertinent sections of 29 CFR 1910, Subpart S and 29 CFR 1926, Subpart K must be complied with and identified in the HASP.

7. Notifications of utilities prior to excavation and trenching per New Jersey

requirements must be detailed and listed in the HASP (1-800-272-1000).

21

Page 31: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

B. Hot Work 1. If no hot work is to be performed on site, then a statement indicating such is

sufficient for this section. 2. The performance of Hot Work such as welding, cutting, etc. during site operations

must be addressed in the HASP. A Hot Work "Permit" procedure must be included in the HASP if hot work is performed and must comply with the sections of OSHA 1910.119(k), OSHA 1910.146 and OSHA 1926.64 (k) et al as they apply to these operations.

3. All hot work procedures should be outlined and shall comply with both state and

local fire codes as well as with OSHA regulations. 4. All electrical supply wiring and distribution shall comply with the local and National

Electric Codes as well as any state and OSHA 1926.400 Subpart K, governing such installations.

5. Proper utilization and storage of flammable cutting gases and other compressed

gases shall comply with the requirements of OSHA 1926.350 et al. All gas cylinders shall be secured from falling or being damaged.

R:\HASPS\MINREQ2000

22

Page 32: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

2001

INDEX OF HEALTH AND SAFETY PLAN SECTIONS Citations from NJ State codes/regulations, 29 CFR 1910.120 and other federal regulations as well as OSSH requirements SECTION SUBJECT CITATION: NUMBER NAME FEDERAL/NJDEP 1.1 Scope of HASP 29 CFR 1910.120 1.2 Site Description NJDEP Contract 1.3 Submittals NJDEP Contract 2.1 Key Personnel (b) (1) (ii) (A) 2.2 Hazard Assessment (b) (4) (ii) (A) 2.3 Employee Training (b) (4) (ii) (B) 2.4 Personnel Protection (b) (4) (ii) (C) 2.5 Medical Surveillance (b) (4) (ii) (D) 2.6 Air Surveillance (b) (4) (ii) (E) 2.7 Site Control (b) (4) (ii) (F) 2.8 Decontamination (b) (4) (ii) (G) 2.9 Site Standard (b) (1) (ii) (F) Operating Procedures 2.10 Contingency Planning (b) (4) (ii) (H) 2.11 Confined Space Oper. (b) (4) (ii) (I) NJSA 34:1-20 et seq 2.12 Spill Containment (b) (4) (ii) (J) 2.13 Special/Permit Oper. 1910.119, 1926.64 1926.350, 1910.146

23

Page 33: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

E-Z HASP FOR (SITE NAME)

FOR ENGAGEMENT INTRODUCTION This site health and safety plan (E-Z HASP) provides site specific guidelines and information for on-site activities. Prior to submittal of this E-Z HASP, a Health and Safety Program (Generic or Programmatic HASP) must be submitted for approval by the Office of Site Safety and Health (OSSH), Division of Publicly Funded Site Remediation, New Jersey Department of Environmental Protection. The Programmatic HASP, used in conjunction with the E-Z HASP, shall comply with 29 CFR 1910.120 (b)(1) and the New Jersey Department of Environmental Protection’s (DEP) Minimum Requirements for contractors conducting work at hazardous waste sites and other related activities. Copies of both this E-Z HASP, and the Programmatic HASP, must be available at the site for the duration of any activities being conducted. SECTION 1 GENERAL SITE INFORMATION Site name: Location (street address) Block(s): Lot(s): City/Town: County: Site Description: (type of operation(s), past use, size/area, known and potential contaminants, previous investigation/remedial activities, media impacted etc…) Starting Date of Proposed Work Anticipated Duration of Project

Page 34: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

SECTION 2 KEY PERSONNEL The following is a list of the names and job functions of all site personnel anticipated to be on site: Project Manager: Project Supervisor: (if different from Manager) On-Site Health and Safety Officer: Corporate Safety Officer: Project Coordinator (DEP): Others: Responsibilities: Project Manager: Project Supervisor: On-Site Health and Safety Officer: Corporate Health and Safety Officer: SECTION 3: SITE OPERATIONS Tasks to be performed: (check all that apply) ( ) Building demolition ( ) Underground tank removal ( ) Capping/paving ( ) Hydropunch or Geoprobe ( ) Monitoring well installation ( ) Sample collection (waste, soil, surface/ground water, etc..) ( ) Excavation/Trenching ( ) Spill cleanup ( ) Waste load out for disposal ( ) Other(s)_________________________________ _________________________________ _________________________________ _________________________________

Page 35: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

Work Zone Map Attached is a site map lay out grid indicating the locations of the work zones, staging areas, exclusion zones, decontamination area, etc.. A B C D E F G H I J

1

2

3

4

5

6

7

8

9

10

Scale 1” = _______ ft Note: Scale is dependent on project size.

Page 36: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

SECTION 4 SAFETY and HEALTH RISK / SITE HAZARDS Contaminant/Waste Characteristics: General Forms: ________solid _____liquid ________sludge _____Gas/vapor Contaminant/Waste classes: ___ corrosive ___radioactive ___reactive ___ toxic ___ignitable __volatile ___unknown ___other Known or suspected contaminant/wastes present: List contaminants and provide MSDS as attachment to HASP. Substances Concentration and Media Primary Exposure Hazard. Known: Potential: Safety hazards: X-mark off items for site hazards ___ heavy equipment ___ excessive noise ___ hoses, tools, etc. lying on ground ( slip, trip, fall ) ___ surface debris (broken glass, sharp objects ) ___ wet or slippery surfaces ___ subsurface/buried objects ___ unstable building structures ___ excavations ___ above ground or underground utilities** ___ stacked drums ___ confined spaces (Confined Space Entry Program required if applicable) ___ motor vehicle traffic ___ poison ivy/oak ___ ticks/other insects ___ infectious waste ___ darkness ___ Other safety hazards: (animals, high crime area etc..)

Page 37: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

**Under Ground Utilities: (gas, water, sewer, cable, phone and electric or process related) As per N.J.S.A. 48:2-73 and in compliance with OSHA Regulation 1926.651, no ground intrusive work is to commence without a current under ground utility mark out. The One-Call system (1 800-727-1000) must be notified not less than 3 full business days before digging. Additional mark outs may be needed to be performed for utilities not covered by One-Call system. The One Call Markout Ticket Confirmation Number(s) will be recorded in the HASP, or attached to the HASP that is kept on site. New Jersey One Call System Confirmation Number: (attach ticket to HASP kept at site) Hazard Prevention: (procedures, steps to be taken, to address all identified site hazards) Potential for heat/cold stress: Temperatures are expected to be in the ___° to ___ ° range. There is a minimal___ , moderate ___, or severe___ potential for heat/cold stress. Safety Item Safety Note Location Phone: Eye wash: First Aid Kit: Fire Extinguishers: Other___

Page 38: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

SECTION 5: PERSONAL PROTECTION Level of Protection ( L.O.P. ) to be employed for each site task . (initial site survey, mobilization, excavation, etc..) TASK INITIAL L.O.P. UPGRADE L.O.P. Personal Protective Clothing/Equipment Check List (may reference Programmatic HAPS) Level D/Modified D*: steel toe/steel shank safety shoes ( ) rubber over-boots or disposable boot covers * ( ) work coveralls ( ) Tyvec coveralls* ( ) outer gloves (type of material – nitrile, PVC, etc.. )* ( ) inner gloves (type material)* ( ) work gloves ( ) hard hat ( ) safety glasses ( ) hearing protection ( ) dust mask (nuisance dust only)* “Modified D” * Modified Level D is defined as any chemical protective clothing ensemble worn without inclusion of an air purifying respirator. Level C: steel toe/shank safety shoes ( ) FULL-FACE RESPIRATOR with appropriate cartridges (identify type) ( ) rubber over boots or disposable boot covers ( ) Tyvec or other appropriate chemical resistant coveralls (identify type of material) ( ) splash/lab apron ( ) outer gloves (material) ( ) inner gloves (material) ( ) hard hat ( ) hearing protection

Page 39: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

Level B: steel toe/shank safety shoes ( ) PRESSURE - DEMAND SCBA ( ) rubber over boots or disposable boot covers ( ) PVC Tyvec or other appropriate chemical resistant coveralls (identify type material) ( ) outer gloves (material) ( ) inner gloves (material) ( ) hard hat Other safety equipment: ( ) hearing protection ( ) traffic cones ( ) face shields ( ) safety vests ( ) tick spray ( ) traffic warning signs ( ) sunscreen ( ) other______________________ ( ) cooler(s) ______________________ SECTION 5: AIR MONITORING Monitoring instruments selected: Contaminant/ Instrument Settings Calibrant Frequency of Use Type Atmosphere (make/model) (span, etc.) (type/conc.) (time period) VOCs LEL/UEL Oxygen Dust Fibers (asbestos) NOTE: Continuous monitoring required for Level C Protection and above. Air Quality Action Levels Organic Vapors (unknown) Background Level D *>Background-5ppm in breathing zone Level C * 5-500 in breathing zone Level B * 500-1000 in breathing zone Level A * Concentrations above background sustained for one minute or longer NOTES: These action levels established by the USEPA Emergency Response Team are guidance only and do not apply to substances with very low TLVs or IDLH concentrations. Action levels should be revised in relation to the presence of known and suspected Substances. There are also substances against which full-face, cartridge equipped masks

Page 40: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

do not protect. Action Levels Condition Range Action Required Oxygen: Less than 19.5% Leave site or go on Supplied Air More than 23.5% Leave site – Fire/Explosion Hazard Combustible Gases: >10% LEL Leave site – Fire/Explosion Hazard Radiation: > 0.08 mR/hr Proceed with caution > 1 mR/hr Continue only on advice of Health Physicist Other Monitoring: (If required, if no other monitoring is anticipated state “NONE”) SECTION 6 - DECONTAMINATION All personnel and portable equipment used on site shall be thoroughly decontaminated before leaving the site. 6.1 Decontamination Procedure for personnel: (include doffing steps, decon solution to be used, how performed) Diagram of Decon Area (Attachment-include steps, locations etc..) 6.2 Decontamination Method/Procedure for Equipment and Instruments: 6.3 Disposal of Contaminated Material: Disposable protective clothing, respirator cartridges and similar items will be bagged for proper disposal. Contaminated rinsate from decontamination of personnel and equipment will be disposed of per state/federal guidelines,unless other arrangements have been made.

Page 41: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

6.4 Decontamination Equipment and Supply Checklist ___ Steam Cleaner/power washer ___ Buckets ___ other ___ Water sprayers ___ Scrub brushes ___ Detergent (Alconox) ___ Deionized water ___ Tap Water ___ Garden Hoses ___ Plastic garbage bags ___ Disposable wipes ___ Poly sheeting ___ 55 gallon drums SECTION 7 - EMERGENCY RESPONSE 7.1 Communication Team members will always work in groups of a minimum of two while on site. Visual contact distance among team members must be maintained at all times. Site Personnel Roles/Line of Authority: Emergency Signals: 7.2 Evacuation: EXAMPLE: In the event of an emergency, such as fire, explosion, toxic gas release etc, personnel will leave the work area or site and meet at a location agreed upon before starting work (case manager’s support vehicle, nearest street, facility entrance etc..) 7.3 Response to Personnel Injury or exposure (indicate procedures) Skin or eye contact: Inhalation: Ingestion:

Page 42: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

EXAMPLE: -Symptoms and First Aid for Heat related injuries: Symptoms of heat stress include: fatigue and muscle weakness; reddening of extremities (ears); cramping of stomach, arms and legs. Symptoms of severe heat injury requiring IMMEDIATE MEDICAL ATTENTION include: seizures, fainting, loss of consciousness, bizarre behavior; profuse sweating than cessation of sweating resulting in hot dry skin. Suggested first aid: Cool victim Remove victim out sun into shaded area (air condition vehicle) Dampen victims clothing and remove excess impervious garments Provide water, if conscious and not vomiting TRANSPORT TO HOSPITAL WHILE ADMINISTERING TREATMENT FOR SEVERE

HEAT INJURIES 7.4 Emergency Decon Procedures If decon cannot be done, the victim will be wrapped in blankets, plastic or rubber to reduce contamination of other on-site personnel and rescue workers. Rescue workers and hospital must be informed if victim is potentially contaminated. HASP, or minimally MSDS material, must accompany the victim to hospital. 7.5 Emergency Information Emergency Service Phone Number(s) Ambulance 911 * Hospital Emergency Room _______________________________ (Name, address and phone #) _______________________________ _______________________________ Local Municipal Offices ________________________________ Police Department _____________________ and/or 911 Fire Department _____________________ and/or 911 HazMat Team DEP “Hot Line” 1-877-927-6337 (1-877 WARNDEP) Poison Control Center 1-800-962-1253 NJDEP Case Manager ________________________________ NJDEP Office of Site Safety and Health 609-984-9779 USEPA Emergency Response 1-800-424-8802 Other ________________________________

Page 43: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

* Per requirements of the NJDEP’s Minimum Requirements, the hospital that is to provide emergency room services to potentially contaminated victims must be notified prior to commencing of site activities. If a employee becomes injured or ill while on the job, transport to the Medical Facility listed in the HASP. State that the injury, or illness, is an "on the job injury" and provide Material Safety Data Sheet for compounds involved if applicable. Hospital must be informed if victim is potentially contaminated. * If the medical emergency is life threatening, call 911 and treat until emergency personnel arrive. If using a cell phone, be clear in providing your location. Route to the Hospital : Attach a map with the route highlighted and written instructions of the route: (provide clear, easy to follow instructions on map) Authorities and responsibilities of authority have been agreed upon with the responding off-site emergency personnel. Attached are written agreements: Fire Department Police Department Medical/EMS Emergency Management Other ________________ SECTION 8 - GENERAL REQUIREMENTS 8.1 Training As per OSHA 1910.120 requirements, personnel engaging in exclusion zone activities must have completed a minimum of 40 hours of environmental safety and health training with a current 8-hour annual refresher. In addition, on-site managers and supervisors directly responsible for or who supervise personnel engaging in field activities shall have completed additional required training in the supervision of those activities. A site safety meeting shall be conducted prior to the start of on-site activities, and before each day’s work, if necessary. This meeting is especially important when site activities are being performed by sub-contractors hired by contractor.

Page 44: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

It is the contractor’s responsibility to insure that any subcontractors it brings on site have the minimum training requirements and that any workers potentially exposed to hazardous materials are enrolled in a medical surveillance program. 8.2 Medical Surveillance All personnel, including contractors, who are potentially exposed to hazardous substances must be enrolled in a medical surveillance program (MSP) and must have had an up-to-date physical, as outlined in Chapter 5 of the Occupational Safety and Health Guidance Manual for Hazardous Waste Site Activities, NIOSH, OSHA, U.S. Coast Guard and U.S. EPA; Oct. 1985. (may reference Programmatic HASP) 8.3 General Safety Rules: (generic examples outlined-may reference Programmatic HASP) a. There will be no eating, drinking, or smoking in the exclusion or contamination reduction zone. b. All personnel must pass through the contamination reduction zone to enter or exit the exclusion zone. c. At a minimum, an emergency deluge shower/spray is to be located in the clean area of the site outside contamination reduction area (for Level C and above). d. All personnel shall wash hands, arms and face before eating, smoking or drinking and at the end of the work day. e. All supplied breathing air shall be certified as grade D or better. f. Where required and practical, all tools/equipment will be spark proof, explosion resistant,

and/or bonded and grounded. g. Fire extinguishers will be on-site for use on equipment or small fires only. 8.4 Confined Space Operations: Confined Spaces are identified at: (If no confined space work anticipated state “NONE”) Confined Space Entry Permits are Required ____ yes ___ no Confined Space Procedure Outline: (may reference Programmatic HASP)

Page 45: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

8.5 Other Safety Precautions and Hazardous Operations a. Site Security: Specify site control measures to address: On site workers from improperly entering controlled zones: Unauthorized entry into site: b. Hot Work Hot Work activities are identified at the following locations and operations: Hot Work Permits will be issued by: Safety precautions to prevent fire or injury are: (may reference Programmatic HASP) c. Spill Control Spill control materials (spill pads/absorbents) are located at: Contaminated materials being excavated, or transferred, are to be monitored and where ever possible be performed in a spill catch area with control materials near by. Precautions and procedures have been established to prevent spills during Transfer Transport Disposal Excavation (may reference Programmatic HASP) The Spill Response Contractor/Personnel to respond to a spill are (list/name):

Page 46: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix B

d. Excavation and Trenching Trenching and Excavation operations are to be performed at (locations): Compliance with the 29 CFR1926 and other federal and local agencies shall be enforced. The following procedures will be followed to address excavation hazards: (sloping shoring, bracing, structural support…) ShellE-Zhasp00CON1

Page 47: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

1

APPENDIX D - GUARD SERVICES SPECIFICATIONS The Contractor shall furnish all labor, materials, equipment, tools, transportation and supplies required to complete the work in accordance with the site specific scope of work. When portions of the work are described in general terms, but not in complete detail, it is understood that only the best practices of any practices typically employed shall prevail. Further, only materials and workmanship of the first quality are to be used and only services of the first quality are to be supplied. A. GUARD SERVICES

The contract(s) generated by this IFB will require selected contractors to provide security guard service at the external boundaries of sites designated by NJDEP. All guard service personnel and the necessary equipment referred to below must be on the site, fully prepared to perform the services described in this Scope of Work. Final details of specific security procedures for specific sites shall be determined through a pre-work conference between NJDEP and the Contractor which shall take place as soon as possible, and not later than three days after notification. Such details shall include, and be based upon, the descriptions and specifications presented in this section and sections 8.2 through 8.4. 1. DUTIES OF GUARDS

a. The guard(s) must control site ingress and egress, 24 hours per day. The Contractor shall provide security guard services for the surveillance and protection of the Site against fire, theft, pilferage, malicious injury and destruction. A sufficient number of guards as determined by NJDEP shall be supplied to accomplish adequate control of site entry point(s) and to monitor periphery of the site efficiently to prevent unauthorized entry.

b. Each guard shall be fully alert and capable at all times of accomplishing all duties

necessary to maintain site security including, but not necessarily limited to the following:

1) Require of all persons attempting to enter site the display of information

sufficient to determine if their entrance is authorized. The information required of each potential entrant may include, but not be limited to, the following:

a. Name b. Identification badge with name and official photo c. Site Specific badge or certificate d. Valid driver’s license e. Valid vehicle registration f. Organization represented 2) Bar entrance to any and all unauthorized individuals. Should it prove impossible

for the guard to bar such entry, he must immediately notify the NJDEP and either the local police or the State Police, or both.

Page 48: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

2

No security guard will resort to physical force against any person, except in self-

defense. 3) Maintain a list, posted, visible, and accessible at all times, of phone numbers of

emergency personnel. The list shall be supplied by NJDEP and will typically include the following:

a. Local fire department b. Local police c. State police local barracks d. Closest hospital e. Closest ambulance service f. On scene coordinator or other relevant NJDEP or USEPA personnel. The guard must have a clear understanding of the chain of command to be

followed in the event decisions must be made regarding unforeseen situations at the site. NJDEP will provide site specific instructions pertaining to the hazards at the site and acceptable responses, including the persons and their telephone numbers to be called and the order in which they are to be called.

4) Keep an up-to-date log, accessible at all times. The log book shall be bound and

at least 8 ½” x 10 ½” in size with numbered pages. All log entries must be neatly and legibly written or printed in ink. An entry must be made in the log at least every hour. The log must include, in chronological sequence, a record of all persons and vehicles entering or leaving the site and relevant information on each sufficient to prove that their entrance was authorized. This shall include at a minimum the names, times, vehicle license plate #, and organization represented. The log must also include records of any and all unusual or otherwise noteworthy events at the site or its immediate vicinity. All such events must be reported to NJDEP as soon as possible and no later than 24 hours after their occurrence.

5) Where a walking guard is utilized, the guard must maintain a regular and punctual

response to a key station monitoring system. At least one key station must be installed at each site; additional stations will be installed by the Contractor at the direction of NJDEP. The key station record shall be subject to NJDEP monitoring at any time. The Contractor will provide a seven (7) day watchclock (such as Detex-Guardsman) with tapes and no more than five (5) key stations. Keys are to be installed at the direction of the Construction Manager or his designee. Security guard contractors shall be paid for only those hours that guard services are performed. Failure to complete a designated round, including the failure to register at any of the mandatory watchclock keys, will result in non-payment for the time-frame involved.

6) Perform any specific patrols, monitoring procedures, etc., as detailed in pre-work

conference. Guards shall not deviate from their prescribed patrol routes. 7) Should hazardous materials or conditions be encountered by a guard working

under supposedly non-hazardous conditions, NJDEP must be notified immediately. At this point, the scope of work may be reduced or changed, a work

Page 49: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

3

stoppage order may be issued and/or the site specific engagement may be terminated pursuant to the Terms and Conditions of this IFB.

2. PERSONNEL REQUIREMENTS a. All guard service personnel assigned to NJDEP sites must have a minimum of six (6)

months experience as a full time security guard, civil policeman or military policeman. If requested, this information must be provided to the State.

b. All guard service personnel must be certified by the Contractor as having completed a

training program of at least 8 hours duration administered by the Contractor. The course must include security guard skills, duties and procedures as normally required by the industry.

c. All guard service personnel must be U.S. citizens, able to read and write English,

physically fit, and possess a valid driver’s license. If requested, this information must be provided to the State.

d. If a guard is judged by NJDEP to be in any way incompetent or non-professional in

his conduct; if the guard fails to perform any of his duties, including his duty to remain fully alert; if the guard has not completed the training program described in b; if the guard does not have the requisite 6 months experience; or if the guard has not completed a training program the guard shall be removed by the Contractor from a site specific project at NJDEP’s request. Any guard so removed must be immediately replaced with a guard who does meet the necessary qualifications.

e. Failure of the Contractor to replace a guard immediately; repeated provision by the

Contractor of guards who are unqualified, incompetent or fail to perform; or receipt by the Contractor of two (2) or more written complaints from NJDEP regarding guard performance are grounds for termination of a site specific engagement.

f. NJDEP shall be allowed to inspect at any time any supervisor’s reports relating to

guard work at a specific site. g. The Contractor must provide additional personnel within 24 hours if deemed

necessary by NJDEP. h. The Contractor must provide supervisory personnel on call 24 hours a day, capable of

being on site within 2 hours, to answer complaints or resolve problems. i. The Contractor shall conduct random visits by management at least once a week to

ensure that all personnel are performing correctly. The Contractor shall furnish written results of these visits to the NJDEP Project Manager with each monthly invoice.

j. Guards shall work 8 hour shifts. In extraordinary circumstances (emergency,

uncovered shift, etc.), guards may work no longer than a 12 hour shift. However, no guard shall work more than a 12 hour shift. There shall be at least an 8 hour break between any two shifts of work for any guard.

k. All guard personnel must wear recognizable uniforms typical of those generally worn

by security guards.

Page 50: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

4

l. Under no circumstances will security guards carry guns unless specifically authorized

to do so by NJDEP. m. All guard services must be performed in full accord with the Private Detective Act of

1939, New Jersey Statute 45:19-8 et seq. n. No personnel will be permitted on-site without the express written permission of the

NJDEP.

3. GUARD HOUSE OFFICE

A guard house office will generally be required for site specific engagements. The following items must be included with the price for a guard house office, and provided on Attachment #1 for Category A, except for utility installation and removal costs and costs of any site specific permits. a. Standard office type trailer with toilet, no smaller than 8’0” x 21’0” or 19’0” if a

separate toilet facility is provided. All maintenance and repairs to the trailer are considered to be part of the cost of the trailer and cannot be billed separately.

b. A portable sanitation unit must be provided if the trailer does not contain sanitary

facilities. c. Must be heated and cooled as necessary to maintain indoor temperature of 72 degrees

F. plus or minus 3 degrees. d. Adequate electrical lighting and sufficient number of electrical outlets must be

supplied. Reimbursement for actual monthly electric bills without markup will be made upon submission of the utility bill with properly completed state invoice.

e. A supply of potable water and disposable cups must be maintained in the office. f. The office must contain one table, at least two chairs, and a lockable, fire resistant file

cabinet. g. Office must be equipped with a fire extinguisher (non-toxic, dry chemical type

meeting Underwriters Laboratories, Inc. approval for Class A, B, and C fires with a minimum rating of 2A:10B:10C).

h. Office must be situated on a spot which maximizes guard’s ability to control site

entrance and monitor periphery of site; this location must be approved by NJDEP. i. Telephone service, either stationary or mobile, must be provided to the office. If

feasible at the site, hard-line telephone service with an outside circuit separate from all others at the site is preferred. The Contractor shall be reimbursed at actual cost with no markup for installation of telephone service and for telephone service fees. Guards must maintain a log of all phone calls. The State will pay for official calls only, i.e., to State offices and/or a pre-approved call list. Reimbursement at cost for approved monthly telephone calls and service fees will be made upon submission of the utility bill with properly completed State invoice.

Page 51: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

5

j. At some locations permits are required of Contractors installing temporary buildings

or establishing utility connections. The Contractor is responsible for obtaining from the appropriate agencies any and all permits for the guard installation. The State will reimburse the Contractor at cost without markup for the cost of permits.

k. The Contractor is responsible for obtaining from the appropriate parties any and all

utilities for the guard house. The State will reimburse the Contractor at cost without markup for any hookup and removal fees or related fees charged by the utility. Reimbursement at cost for approved monthly utility bills will be made upon submission of the utility bill with properly completed state invoice.

l. Failure of the Contractor to supply all required equipment as specified above after

two (2) or more written complaints are grounds of termination of the site specific engagement.

m. The guard service shall be responsible for any trash generated. Responsibilities,

including costs, shall include proper handling and disposal of the trash.

4. FIREARMS

Should guards armed with a revolver or pistol be required by the State, such guards must have the necessary training and permits. A copy of the Permit to Carry Handgun shall be presented to NJDEP for each guard prior to engagement.

5. GUARD SERVICE WORK ITEMS a. Normal work hours for guard service personnel shall be one 8 hour shift per 24 hour

period. A normal work week for such personnel shall be five 8 hour shifts per seven day period. No guard shall work more than a 12 hour shift. There shall be at least an 8 hour break between any two shifts of work for any guard.

b. Guard service shall normally be provided at a site 24 hours per day, seven days a

week.

Page 52: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

Appendix E Fire Fighting Personal Protective Gear “Level F” The minimum acceptable ensemble for “level F” is: 1. NFPA Standard 1971 compliant protective coat and trousers designed for

structural fire fighting as defined in NFPA 1971, 2. NFPA Standard 1972 compliant helmet for structural firefighting,

equipped with a face shield and worn in conjunction with a Nomex or equivalent hood,

3. NFPA Standard 1973 compliant gloves for structural fire fighting, and 4. NFPA Standard 1974 compliant protective footwear for structural

firefighting. If the NFPA updates, revises, or supercedes any of these standards during the contract term, then the most current Standard shall be used. The ensemble should be in good repair and have been properly dried and cleaned after its last use prior to being placed in service under this contract.

Page 53: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

APPENDIX F

STATE OF NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION

DIVISION OF PUBLICLY FUNDED SITE REMEDIATION CONTRACTOR CLAIM FORM #1

INITIAL NOTICE OF CLAIM Date: A. Project/Site Name: B. Contract Name and Number: C. Contractor Name: D. Contractor Address: E. Amount of Claim: (money and/or time) F. Contract Provision(s) Under Which Claim is Made: G. Description of Circumstances Giving Rise to Claim (Such as changes in quantity or nature of work, changes in site conditions, delay caused by the State, or other circumstances stated by particularity): (Use additional sheets as necessary) I certify that the foregoing statements made by me are true. I am aware that if any statement made herein is willfully false or fraudulent, I am liable to punishment provided by law. I further certify that I have made a good faith effort to disclose the full nature and extent of this claim in the above answers. __________________________________________ Signature of Contractor’s Authorized Representative __________________________________________ Typed Name and Title of Signatory

Page 54: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

APPENDIX F

STATE OF NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION

DIVISION OF PUBLICLY FUNDED SITE REMEDIATION CONTRACTOR CLAIM FORM #2

ANALYSIS AND DOCUMENTATION OF CLAIM Date: A. Project/Site Name: B. Contract Name and Number: C. Contractor Name: D. Contractor Address: E. Claim Number: F. History of Claim (Including when the claim accrued; what allegedly caused the claim;

what, if any, prior communications the Contractor had with the State about the claim; what is the contractual and/or legal basis for concluding that the Contractor is entitled to a claim under the circumstances alleged);

G. Analysis and Documentation of Costs Incurred and Labor Hours Expended (Analysis

should discuss what pay items have been affected; what labor, equipment and/or materials have been added or wasted; what performance or delivery schedules have been affected; and, what costs have been increased. Documentation should include auditable time sheets for employees and payroll records for employee’s hourly rates, and itemized non-salary expenses supported by in-house ledgers or logs and/or invoices or canceled checks):

H. Efforts Made by the Contractor to Mitigate Costs and Effects of Claim: (Use additional sheets for Items F, G and H and attach documentation). I certified that the foregoing statements made by me are true. I am aware that if any statement made herein is willfully false or fraudulent, I am liable to punishment provided by law. I further certify that I have made a good faith effort to disclose the full nature of this claim in the above answers. __________________________________________ Signature of Contractor’s Authorized Representative __________________________________________ Typed Name and Title of Signatory

Page 55: BID DOCUMENTS NJDEP EMRRGENCY SERVICES TERM CONTRACT · 2005-10-28 · An air monitoring program is part of all response operations when atmospheric contamination is known or suspected.

APPENDIX F

CONFLICT OF INTEREST CERTIFICATION I am an officer of the firm listed below and am completing this certification on its behalf. I have examined the list of persons and/or entities itemized below: Pursuant to the Conflict of Interest Section of this IFB, I hereby affirm that the firm has: A. ______ Had no contractual or other business relationship with any of these persons or entities. ______ Had relationships with the persons or entities as listed and described below. B. ______ Done no work on or with respect to the site. ______ Done work on or with respect to the site as listed and described below. __________________________________ ________________________________ Date Signature ________________________________ Type or Print Name ________________________________ Name of Proprietorship, Partnership or Corporation Submitting Form