BGR-SA Series
Transcript of BGR-SA Series
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
96-01153 / rev f / 7-5-17
BGR-SA Series 19” gangable enclosures
next generation rack, designed with significant installation and performance benefits
feat
ures
: • Provides more rackspace in a smaller overall height than similar racks
• Accepts patent-pending Lever Lock™ tool free and hardware free internal device and cable management system accessories
• Fully welded construction provides the following weight capacities: UL Listed load capacity: 3,000 lbs., Seismic certified capacity: 1,175 lbs.
• Pre-threaded ganging holes allow for rack joining after loading
• Rackrail depth indicators
• 1/2”, 3/4”, 1” & 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/VHF antennae knockouts on rear top & bottom, easily removable for cable pass-through. Top cable management plate (38 space and up) includes 1/2”, 3/4”, 1” 1-1/2” & 3” electrical knockouts and 5/8” and 1/2” D UHF/VHF antennae knockouts
• 23” OD width, multiple depths
• Two pairs of 11-gauge, 10-32 threaded rackrail with numbered rackspace increments
• Optional stackable 3” extender bay available for front and rear
• Optional curved and beveled front doors in solid, vented and plexiglass styles
• Attractive interior bevels
• Configurable open top with vertical cable management entry points
• Durable black textured powder coat finish
• Seismic certified (when used with BGR-Z4 or BGR-ISO-Z4 option) with an Ip value of 1.5
• UL Listed in the US and Canada
BGR shown with curved door and side panels
BGR shown with beveled door and side panels
EIA/TIA COMPLIANT
SEISMIC CERTIFIED
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
2
BGR Series 19” gangable enclosures
EIA compliant 19” gangable equipment rack shall be Middle Atlantic Products model #BGR-__- __(see chart for available models). Overall dimensions of BGR shall be __”H x 23”W x __”D (refer to chart). Useable height of BGR shall be __ rackspaces, useable depth shall be__” (refer to chart). BGR shall come equipped with two pairs of fully adjustable steel rackrail with tapped 10-32 mounting holes in universal EIA spacing, black e-coat finish and numbered rackspaces. BGR shall have .100” thick steel along rackrail brackets, .310” thick steel at corners. BGR shall include vented locking and latching rear door, which shall be capable of accepting up to six 4-1/2” fans. Top and bottom of BGR shall feature vertical slotted vent pattern for ventilation. BGR shall have two 1” x 7”rear obround knockouts with 1/2”, 1”, 1-1/4” and 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/ VHF antennae knockouts in base and top. BGR shall have a configurable open top with vertical cable management entry points. BGR shall accept patent-pending LeverLock™ tool free and hardware free internal cable and device management system accessories. BGR shall have pre-threaded 5/16”-18 ganging holes. BGR shall be capable of ganging while fully loaded, using bolts only. BGR shall have marked rackrail depth indicators. BGR shall be of fully welded construction. BGR shall be finished in an environmentally friendly, durable black powdercoat. Grounding and bonding studs shall be 1/4-20 threaded, installed in top and base of enclosure (19 and 25 space have stud in bottom only). Fully welded construction shall provide a static capacity of 12,000 lbs. and a UL Listed load capacity of 3,000 lbs. BGR Series enclosures shall satisfy the 1997 UBC; 2001, 2007 & 2010 CBC; 2000, 2003, 2006 & 2009 IBC; ASCE 7-02, ASCE 7-05, ASCE 7-10 and the 2003, 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity, Seismic Use Group III, Zone 4 or Seismic Design Category (SDC) “D” with lateral force requirements for protecting 1,175 lbs. of essential equipment in locations with the highest level of seismicity and top floor or rooftop installations with an Importance factor ( Ip) of 1.5 when used with BGR-Z4 or BGR-ISO-Z4 (isolated) seismic floor anchor bracket. BGR shall be OSHPD approved for fixed equipment anchorage in California healthcare facilities. BGR shall be UL Listed in the US and Canada. BGR shall be GREENGUARD Gold Certified. BGR enclosure shall meet the RoHS EU Directive 2011/65/EU. BGR shall be manufactured by an ISO 9001 and ISO 14001 registered company. BGR enclosure shall be warrantied to be free from defects in material or workmanship under normal use and conditions for the lifetime of the rack.
Customizable specification clips available at middleatlantic.com
spec
ificat
ions
:
options:• Lever Lock™ tool free and hardware free internal device and cable management system accessories shall be model # LL-XXYY (XX = type, YY = size, refer to middleatlantic.com for additional details)
• Curved front doors shall be model # VFD-XXA (vented, 64% open area), PFD-XXA (plexi), (XX= # of rackspaces)
• Beveled front doors shall be model # BFD-XX (solid), BVFD-XX (vented, 64% open area), BPFD-XX (plexi), (XX= # of rackspaces)
• Front or Rear Extender, adds 3” of usable depth, model # BGR-__-EXT3 (41,45)
• Cable entry rear door, shall be model # BGR-RDC__ (19, 25, 38, 41, 45)
• Inner platform base shall be BS-BGR
• Caster kit shall add 1” to overall height, include four casters with a 1,100 lb. weight capacity, and shall be model # CBS-BGR
• Rear rail kit shall be model # BGR-RRXX (XX=# of rackspaces)
• Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” compliancy kit shall be model # BGR-Z4
• Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” compliancy and isolation kit shall be model # BGR-ISO-Z4
• Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” riser bases shall be SRB-(1,2,3)-BGR-(32, 38)24
• Isolation kit shall be model # BGR-ISO
• Front decorative trim shall be BGR-TRIM__(45,41,38, 25, 19) and shall include the following colors: Green (pre-installed), Red, Black, Blue & White
Part # Rackspaces“A”
Overall Height“B”
Racking Height“C”
Depth“D”
Useable Depth
BGR-19SA-27 19 37.375 [949] 33.375 [848] 27 [686] 24.4 [620]
BGR-25SA-27 25 47.875 [1216] 43.875 [1114] 27 [686] 24.4 [620]
BGR-38SA-27 38 70.625 [1794] 66.625 [1692] 27 [686] 24.4 [620]
BGR-41SA-27 41 75.875 [1927] 71.875 [1826] 27 [686] 24.4 [620]
BGR-45SA-27 45 82.875 [2105] 78.875 [2003] 27 [686] 24.4 [620]
BGR-25SA-32 25 47.875 [1216] 43.875 [1114] 32 [812] 29.4 [747]
BGR-38SA-32 38 70.625 [1794] 66.625 [1692] 32 [812] 29.4 [747]
BGR-41SA-32 41 75.875 [1927] 71.875 [1826] 32 [812] 29.4 [747]
BGR-45SA-32 45 82.875 [2105] 78.875 [2003] 32 [812] 29.4 [747]
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
3
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Series basic dimensions
top view top view25SP & under
top panel detail
front view side view rear view
detail A
38SP & up
fixed hole for optional wood top 1/4-20 x 1” grounding stud
5/8” [16] LKO for UHF/VHF antenna3xø1/2” [13] ‘D’ LKO for
UHF/VHF antenna
1.32 [34] 7.56 [192] ø1.33 [34] x 7.50 [190] LKO
2x 1/2” [13] EKO trade size
2x 1” [25] x 1-1/4” [32] EKOtrade size
23.0 [584]
1.00 [25]21.00 [533]
1.42[36]
1.31[33]
21.13[537]
“C”
keyhole LKO for optional wood top
4x 3” [76] x 1-1/2” [38] x 1” [25] EKO trade size
Lever Lock™
compatiblehorizontal
Lever Lock™
compatiblevertical
bottom view1.86 [47] 19.90 [505]
(bottom opening)
19.15[486]
BGR-XXSA-27=21.91 [556]BGR-XXSA-32=26.91 [683](bottom opening)
4xø.69 [17] (floor mounting holes)1/4-20x1”
(grounding stud)
BGR-XXSA=23.16 [588]BGR-XXSA-32=28.16 [715]
(floor mounting holes)
4xø1/2” [13] ‘D’ LKO for UHF/VHF antenna
4xø.688 [17,48] LKO
1.91 [48]
5x 3.75 [95]
2.00 [51]2.03 [52]
“B”
2.00[50,8]
“A”
“C”
2xø1.33 [34] x 7.50 190] LKO
22.38 [568]
2.22[56]
5x 3/4” [19] x 1/2” [13] EKO trade size
40xø.38 [9,5]LKO for ganging
23.0 [584]
vents in rear dooralso accept4-1/2” fans
see detail A
“D”max rear rail
set back(usable depth)
2x 1.29 [32,7]
5.22[133]
2xø5/8” [16] ‘D’ LKO for UHF/VHF antenna
21.0 [533] x 21.13 [537]rect LKO
4x ø1/2” [13] ‘D’ LKOfor UHF/VHF antenna
2x 4-1/2” fan knockouts
2x ø5/8” [16] LKOfor UHF/VHF antenna
“C”
4.61[117]
13.00[330]
23.0 [584]
38SP & under
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
4
curved doors
beveled doors
22.0 [559]
A
110º
110º
1.58 [40.1]clearance from frontof rail to curved doorframe surface 2.6 [66] ref.
.87 [22.1] ref.
2.75 [69.9]
(17.46 [443.6])inside dim. betweendoor frame
A
21.85 [555]
BFD-XX 2.79 [71]BVFD-XX 2.74 [70]BPFD-XX 2.60 [66]
BPFD-45 BFD-45
popout latching and locking handle
BVFD-45clearance from front of
rail to inside of door
open direction pivot point
insert material:plexi or perf.
popout latching and locking handle
Solid Door Vented Door Plexi Door RackspacesA
Height
BFD-19 BVFD-19 BPFD-19 19 36.22 [920]
BFD-25 BVFD-25 BPFD-25 25 46.72 [1187]
BFD-38 BVFD-38 BPFD-38 38 69.47 [1765]
BFD-41 BVFD-41 BPFD-41 41 74.72 [1898]
BFD-45 BVFD-45 BPFD-45 45 81.72 [2076]
Vented Door Plexi Door RackspacesA
Height
VFD-19A PFD-19A 19 35.97 [913]
VFD-25A PFD-25A 25 46.47 [1180]
VFD-38A PFD-38A 38 69.22 [1758]
VFD-41A PFD-41A 41 74.47 [1891]
VFD-45A PFD-45A 45 81.47 [2069]
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Seriescurved & beveled doors basic dimensions
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
5
top view
front/rear extender
cable chase
top view
attaches front andback CC w/ 5/16-18x5
ganging hardware
attaches top CCwith 5/16-18x1ganging hardware
LKO (front and back)for lock (lock included)
23.0 [584]
23.0 [584]
BGR-45-EXT3= 82.86 [2105]
BGR-41-EXT3= 75.86 [1927]
3.0 [76]
3.0 [76]
1.32 [34] 7.56 [192]
1.99 [51]
1.99 [51]
front view side view
front view side view
rear viewø1.33 [34] x 7.50 [190] lko2x 1/2" [13] eko trade size
2x 1" [25] x 1-1/4" [32]eko trade size
5/8" [16] lko for UHF/VHF antenna3x ø 1/2" [13] 'd' lko forUHF/VHF antenna
BGR-CC-45FB = 82.7 [2100]
BGR-CC-41FB = 75.7 [1922]
BGR-CC-38FB = 70.4 [1788]
.09 [2.3]vert gapbetween topand bot CC
.06 [1.5] gap betweentop and front and back CC
BGR-CC-38LT= 38.0 [965]
BGR-CC-32LT= 32.0 [813]
BGR-CC-27LT= 27.0 [686]
4.4 [112](front and backCC width)
4.5 [114] (top CC width)
1.9[49] BGR-CC-45FB
= 41.3 [1049]BGR-CC-41FB
= 37.9 [963]
BGR-CC-45FB = 41.3 [1049]
BGR-CC-41FB = 37.9 [963]
BGR-CC-38LT= 35.0 [889]BGR-CC-32LT= 29.0 [737]BGR-CC-27LT= 24.0 [610]
2.7 [68]
2x 3" [76] x 2" [51] EKO trade size (BGR-CC-27LT)4x 3" [76] x 2" [51] EKO trade size (BGR-CC-32LT)6x 3" [76] x 2" [51] EKO trade size (BGR-CC-38LT)
ø1.3 [33] x 7.5 [191] IKO
Part # Used On
BGR-CC-45FB BGR-45XX, BGR-45SA-XX
BGR-CC-41FB BGR-41XX, BGR-41SA-XX
BGR-CC-38FB BGR-38XX, BGR-38SA-XX
BGR-CC-38LT BGR-XX38
BGR-CC-32LT BGR-XX32, BGR-XXSA-32
BGR-CC-27LT BGR-XX27, BGR-XXSA-27
Part # Used On
BGR-45-EXT3 BGR-45XX, BGR-45SA-XX
BGR-41-EXT3 BGR-41XX, BGR-41SA-XX
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Seriesfront/rear extender & cable chase basic dimensions
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
6
15.72[399]
22.38 [568]
1.53 [39]
.23 [6]1.05 [27] 15.72
[399]
6.97[177]
BGR-276FT shownBGR-552FT-FC shown
Top Panel/Rail
22.38 [568]
BA
AB
.06 [2]
2.23 [57]
14.22[361]
19.0 [483]
.519 [13]
7.86 [200]
ø7.13 [181]
BGR-DT9, for use withDUCT-COOL-1PT and DUCT-COOL-2PT
11.19 [284]
BGR-STP4
BGR-LVT9 tapped10-32
15.72[399]
22.38 [568]
1.53 [39]
.23 [6]1.05 [27] 15.72
[399]
6.97[177]
BGR-276FT shownBGR-552FT-FC shown
Top Panel/Rail
22.38 [568]
BA
AB
.06 [2]
2.23 [57]
14.22[361]
19.0 [483]
.519 [13]
7.86 [200]
ø7.13 [181]
BGR-DT9, for use withDUCT-COOL-1PT and DUCT-COOL-2PT
11.19 [284]
BGR-STP4
BGR-LVT9 tapped10-32
Part #Fan
ControlFan
QuantityAirflow CFM
[M3/MIN]Noise @ Full
Speed Current Draw
(I) BGR-276FT 4 276 [7.8] 35dBa 620 mA @ 12VDC
(I) BGR-276FT-FC X 4 276 [7.8] 35dBa 620 mA @ 12VDC
(I) BGR-552FT 8 552 [15.6] 38dBa 1.24A @ 12 VDC
(I) BGR-552FT-FC X 8 552 [15.6] 38dBa 1.24A @ 12 VDC
Part # A B Type MaterialOpenArea
BGR-STP3 5.22 [133] 2.25 [57] solid aluminum -
BGR-STP4 6.97 [177] 4.00 [102] solid aluminum -
BGR-STP9 15.72 [399] 12.75 [324] solid steel -
BGR-LVT9 15.72 [399] 12.75 [324] vented steel 64%
BGR-DT9 15.72 [399] 12.75 [324] duct top steel -
Part # A B Rackspaces
BGR-TRR4 6.97 [177] 4.00 [102] 4
BGR-TRR9 15.72 [399] 12.75 [324] 9
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Seriesfan top & top panel/rail basic dimensions
Note:1. Turn on temperature for fan controlled models can be set at 75°F (24°C), 80°F (27°C), 85°F (29°C), or 90°F (32°C). Alarm can be set at 95°F (35°C) or 100°F (38°C).
2. “I” prefix indicates international fan top models. International models come with a universal voltage plug-in power supply and adapters.
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
7
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Seriescaster base / inner platform base basic dimensions
BGR-XX27 11.96 [304]BGR-XX32 16.96 [431]BGR-XX38 22.96 [583]
19.90 [505]
BGR-XX27 3.75 [95]BGR-XX32 8.75 [222]BGR-XX38 14.75 [375]
19.90 [505]
installing casterbase torack will increase overallheight by 1.12 [28]
22.62 [575]
6.33[161]
22.68 [576]
10.47[266]
4.89[124]
19.74 [501]
2.84 [72]
19.74 [501]
2.0 [51]
9.0[229]
BS-BGR
CBS-BGR
middleatlantic.com | middleatlantic.ca
what great systems are built on.™
8
Part # Used On“A”
Height
BGR-RDC19 BGR-19XX, BGR-19SA-XX 29.59 [752]
BGR-RDC25 BGR-25XX, BGR-25SA-XX 40.09 [1018]
BGR-RDC38 BGR-38XX, BGR-38SA-XX 62.84 [1596]
BGR-RDC41 BGR-41XX, BGR-41SA-XX 68.09 [1730]
BGR-RDC45 BGR-45XX, BGR-45SA-XX 75.09 [1907]
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR-SA Seriescable entry rear door basic dimensions
.72 [18] 19.56 [497]
A
A
19.84 [504]
ø 20 [5] holefor documentholder (part#DOC-SACK)
vents in reardoor also accept4-1/2"fans
rear door brushcable entry panel,mounts top orbottom
2.50 [64] height x15.00 [381] width
brush opening