Beyond Compliance: Energy Efficient Solutions presentation

36
ENERGY EFFICIENT FACADES ASTANA EXPO 2017 PROJECT Sara Beardsley – Sr. Architect AIA, LEED AP ADRIAN SMITH + GORDON GILL ARCHITECTURE

description

Beyond Compliance: Energy Efficient Solutions presentation by Sara Beardsley, Adrian Smith + Gordon Gill Architecture - Facades+ Chicago 2015 conference

Transcript of Beyond Compliance: Energy Efficient Solutions presentation

Page 1: Beyond Compliance: Energy Efficient Solutions presentation

ENERGY EFFICIENT FACADESASTANA EXPO 2017 PROJECT

Sara Beardsley – Sr. ArchitectAIA, LEED AP

A D R I A N S M I T H + G O R D O N G I L LA R C H I T E C T U R E

Page 2: Beyond Compliance: Energy Efficient Solutions presentation

THE BUILDINGS WERE DESIGNED TO TOTAL POST-EXPO GRID ENERGY DEMAND OF 47% LESS THAN AN ASHRAE 90.1 2010 BASELINE.

© Adrian Smith + Gordon Gill Architecture, 2015

Page 3: Beyond Compliance: Energy Efficient Solutions presentation

ASTANA EXPO MASTERPLAN WAS DESIGNED TO BE 100% POWERED FROM RENEWABLE ENERGY PROVIDED BY ON-SITE SOLAR AND WIND SYSTEMS AND OFFSITE WIND ENERGY

© Adrian Smith + Gordon Gill Architecture, 2015

Page 4: Beyond Compliance: Energy Efficient Solutions presentation

DESIGNED FOR 28% OF THE POST-EXPO ELECTRICAL DEMANDTO BE MET FROM ON-SITE BIPV ENERGY SYSTEMS. © Adrian Smith + Gordon Gill 

Architecture, 2015

Page 5: Beyond Compliance: Energy Efficient Solutions presentation

OFFICE BUILDINGS DURING POST-EXPO DESIGNED TO USE 21%-39% LESS ENERGY THAN ASHRAE 90.1:2010 BASELINE © Adrian Smith + Gordon Gill 

Architecture, 2015

Page 6: Beyond Compliance: Energy Efficient Solutions presentation

BUILDINGS’ ENVELOPE DESIGN EXCEEDS PASSIVE HOUSE LEVELS OF THERMAL INSULATION.

© Adrian Smith + Gordon Gill Architecture, 2015

Page 7: Beyond Compliance: Energy Efficient Solutions presentation

MASTER PLAN – EXPO MODE.

Page 8: Beyond Compliance: Energy Efficient Solutions presentation

chicago astana

Page 9: Beyond Compliance: Energy Efficient Solutions presentation

chicago astana

Page 10: Beyond Compliance: Energy Efficient Solutions presentation
Page 11: Beyond Compliance: Energy Efficient Solutions presentation
Page 12: Beyond Compliance: Energy Efficient Solutions presentation

EXPO 2017EXTERIOR WALL DESIGN PRINCIPLES:

- TARGET 40% GLAZING RATIO OR LESS

- TILTED FACADES TO REDUCE SUMMER SOLAR GAIN

- USE OF BIPV

- USE OF SKYLIGHTS AND ATRIUMS IN CERTAIN BUILDINGS FOR STRATEGIC NATURAL LIGHT

- HIGH PERFORMANCE TRIPLE GLAZING

Page 13: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 14: Beyond Compliance: Energy Efficient Solutions presentation

INTERNATIONAL AND THEMATIC PAVILIONS

Page 15: Beyond Compliance: Energy Efficient Solutions presentation

SHINGLED WALL

USE OF TRIPLE PANE WINDOW

LOW GLAZING RATIO

BIPV ROOF AND CANOPY

Page 16: Beyond Compliance: Energy Efficient Solutions presentation
Page 17: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 18: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 19: Beyond Compliance: Energy Efficient Solutions presentation

KAZAKHSTAN PAVILION – TECHNOLOGY MUSEUM

DOUBLE CURVED GLASS

FRIT PATTERN

USE OF ATRIUM SPACE

RENEWABLE ENERGY

Page 20: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 21: Beyond Compliance: Energy Efficient Solutions presentation
Page 22: Beyond Compliance: Energy Efficient Solutions presentation
Page 23: Beyond Compliance: Energy Efficient Solutions presentation
Page 24: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 25: Beyond Compliance: Energy Efficient Solutions presentation
Page 26: Beyond Compliance: Energy Efficient Solutions presentation
Page 27: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 28: Beyond Compliance: Energy Efficient Solutions presentation

ART CENTER

© Adrian Smith + Gordon Gill Architecture, 2015

ART CENTER

Page 29: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

USE OF EARTH BERM, SKYLIGHT AND TILTED GLASS

Page 30: Beyond Compliance: Energy Efficient Solutions presentation
Page 31: Beyond Compliance: Energy Efficient Solutions presentation

CONGRESS CENTER BUILDING

LOW GLAZING % WITH STRATEGIC NATURAL LIGHTING FOR WINTER HEAT GAIN

SUMMER WINTER

Page 32: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 33: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 34: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015

Page 35: Beyond Compliance: Energy Efficient Solutions presentation

EXPO HOTEL

EAST/WEST PRIMARY FACADES

SOLAR SHADING DEVICES

VERTICAL FACETED FAÇADE

TRIPLE GLAZING

Page 36: Beyond Compliance: Energy Efficient Solutions presentation

© Adrian Smith + Gordon Gill Architecture, 2015