BEST IN CLASS SOLUTIONS WITH ... - Hilti Singapore · PDF fileFREE calculation software and...

1
What does it mean for contractors Structural connections with post-installed rebar Ensure that the execution of the jobsite is according to the specifications. Ensure that the installer is capable of correctly installing the anchor. Should ensure that the change management procedure outlined in clause 10 is followed when an alternative anchor is proposed to that specified. If aware of any changes to the assumptions made by the specifier in designing / selecting the specified anchor, should Inform the specifier and await instructions. Especially suitable for large-diameter and/or deep embedment depths ETA for rebar: Approved rebar size is stated within ETA on page 3 Hilti. Outperform. Outlast. Customer Service: 6777-7887 Hilti Far East Pte Ltd | 20 Harbour Drive, #06-06 PSA Vista, Singapore 117612 | T 6777 7887 | F 6777 3057 | www.hilti.com.sg Hilti = registered trademark of Hilti Corp., Schaan | Printed in Singapore | May 2015 | © 2015 | Right of technical and programme changes reserved S. E. & O. BS8539 is the code of practice for selection and installation of post-installed anchoring. It is also linked to the relevant European regulations, especially with respect to selecting products with the CORRECT European Technical Approval or Assessment’s (ETA) for the application. Who does it affect? Everyone; designers, specifiers, contractors, installers, testers, manufacturers and suppliers. HIT-RE500 (SD) Epoxy Adhesive Anchor designed to meet the most stringent standards of the latest building codes. Anchoring structural steel connections Fulfills the requirements of the most demanding ETA C2 approvals for seismic applications ETA for anchor (cracked / uncracked concrete): Approved anchor size is stated on cover page HIT-HY200-R achieves the highest bond strength of all adhesive mortar. BS8539 Your Roles and Responsibilities for Post-Installation Hilti offers best in class solutions with international ETA approvals HILTI can offer support from design to installation. FREE calculation software and design with PROFIS Installation training for contractors on-site to ensure safe use On-site support Hilti provides 2.5% complimentary on-site pull-out test (e.g. extension/connection to walls, slabs, stairs, columns, foundations, etc.) (e.g. steel columns, beams, etc.) Hilti. Outperform. Outlast. Eurocode, EC2 Use? BEST IN CLASS SOLUTIONS WITH INTERNATIONAL ETA APPROVALS. European Technical Assessment ETA-12/0083 of 13 May 2014 General Part Technical Assessment Body issuing the European Technical Assessment: Deutsches Institut für Bautechnik Trade name of the construction product Injection System Hilti HIT-HY 200-R for rebar connection Product family to which the construction product belongs Post-installed rebar connection with Hilti injection mortar HIT-HY 200-R t f a h c s l l e s e g n e i t k A i t l i H r e r u t c a f u n a M 9494 SCHAAN FÜRSTENTUM LIECHTENSTEIN e k r e W i t l i H t n a l p g n i r u t c a f u n a M This European Technical Assessment contains 22 pages including 18 annexes which form an integral part of this assessment This European Technical Assessment is issued in accordance with Regulation (EU) No 305/2011, on the basis of Guideline for European technical approval of "Metal anchors for use in concrete", ETAG 001 Part 5: "Bonded anchors", April 2013, used as European Assessment Document (EAD) according to Article 66 Paragraph 3 of Regulation (EU) No 305/2011. Structural Rebar connections - EC2 / EOTA TR023 Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment Applications Technical data Productivity plus Productivity plus Structural rebar connections and extensions can be safely designed like cast-in connections utilizing the design provisions provided within Eurocode 2 and EOTA TR023 *Test in cracked concrete is not required according to TR023. Approvals Rebar Diameter Range ETA for rebar connections 4 hours fire resistance T8 – T40 ETA 08/0105, ETA11/0492 Structural connections with post-installed rebars Structural renovation / upgrades with post-installed rebars Substitution of misplaced / missing rebars Reinforced concrete waler with post-installed rebars Eurocode, EC2 use? On 1st April 2015, Eurocode design standard has replaced British Standards as Singapore’s prescribed building codes for structural design (http://www.bca.gov.sg/Newsroom/pr25032013_EC.html). This also means that there is now a specific set of codes that also addresses the design method post-installed rebar and anchors. In EC2 Clause <EN1992-1-1:2004 (E)>, it states that the design methods for post-installed rebar connections must follow EC2/Technical Report 023. And for post-installed anchors, the design must follow ETAG 001 Annex C. Thus, the design methods for the two applications are completely different. Anchor connections - ETAG 001 Annex C / TR 029 Applications The European Technical Approval Guideline 001 “Metal Anchors for used in Concrete” sets out the basis for assessing anchors to be used in concrete. Wide range of fastening applications in concrete Anchoring structural steel connections (e.g. steel columns, beams) Anchoring secondary steel structures (e.g. staircases, steel ledgers) Anchoring railings / safety barriers Fastening façade brackets Fastening brackets and channels Technical data Approvals Mechanical anchor diameter range Threaded rod diameter range Rebar diameter range ETA for cracked or uncracked concrete 2 hours fire resistance M6 – M24 M8 – M39 M8 – M32 Traditional Method With Hilti Hollow Drill Bit and VC 20/40 Vacuum Up to 60% faster! Hilti PROFIS Rebar for design calculation for rebar connections Cordless electric dispensers for quick, efforless injection Injectable mortars for versatile, secure fastenings in concrete Powerful combihammers for tough drilling jobs Hilti PROFIS Rebar Hilti PROFIS Anchor for design calculation for anchor connections Service and advice to ensure the job is done right Injectable mortars for versatile, secure fastenings in concrete Powerful cordless combihammers for tough drilling jobs Traditional Method HIT-HY 200 System with HIT-Z rods Up to 60% faster! Hilti PROFIS anchor ,

Transcript of BEST IN CLASS SOLUTIONS WITH ... - Hilti Singapore · PDF fileFREE calculation software and...

Page 1: BEST IN CLASS SOLUTIONS WITH ... - Hilti Singapore · PDF fileFREE calculation software and design with PROFIS Installation training for contractors on-site to ensure safe use On-site

What does it mean for contractors

Structural connections with post-installed rebar

Ensure that the execution of the jobsite is according to the specifications.

Ensure that the installer is capable of correctly installing the anchor.

Should ensure that the change management procedure outlined in clause 10 is followed when an alternative anchor is proposed to that specified.

If aware of any changes to the assumptions made by the specifier in designing / selecting the specified anchor, should Inform the specifier and await instructions.

Especially suitable for large-diameter and/or deep embedment depthsETA for rebar: Approved rebar size is stated within ETA on page 3

Hilti. Outperform. Outlast. Customer Service: 6777-7887

Hilti Far East Pte Ltd | 20 Harbour Drive, #06-06 PSA Vista, Singapore 117612 | T 6777 7887 | F 6777 3057 | www.hilti.com.sg

Hilt

i = r

egis

tere

d t

rad

emar

k o

f H

ilti C

orp

., S

chaa

n | P

rint

ed in

Sin

gap

ore

| M

ay 2

015

| © 2

015

| Rig

ht o

f te

chni

cal a

nd p

rog

ram

me

chan

ges

res

erve

d S

. E. &

O.

BS8539 is the code of practice for selection and installation of post-installed anchoring. It is also linked to the relevant European regulations, especially with respect to selecting products with the CORRECT European Technical Approval or Assessment’s (ETA) for the application. Who does it affect? Everyone; designers, specifiers, contractors, installers, testers, manufacturers and suppliers.

HIT-RE500 (SD) Epoxy Adhesive Anchor designed to meet the most stringent standards of the latest building codes.

Anchoring structural steel connections

Fulfills the requirements of the most demanding ETA C2 approvals for seismic applicationsETA for anchor (cracked / uncracked concrete): Approved anchor size is stated on cover page

HIT-HY200-R achieves the highest bond strength of all adhesive mortar.

BS8539 Your Roles and Responsibilities for Post-Installation

Hilti offers best in class solutions with international ETA approvals

HILTI can offer support from design to installation.•

••

FREE calculation software and design with PROFISInstallation training for contractors on-site to ensure safe useOn-site supportHilti provides 2.5% complimentary on-site pull-out test

(e.g. extension/connection to walls, slabs, stairs, columns, foundations, etc.)

(e.g. steel columns, beams, etc.)

Hilti. Outperform. Outlast.

Eurocode, EC2 Use?

BEST IN CLASS SOLUTIONS WITH

INTERNATIONAL ETA APPROVALS.

Z30836.14 8.06.01-106/14

European Technical Assessment

ETA-12/0083 of 13 May 2014

General Part Technical Assessment Body issuing the European Technical Assessment:

Deutsches Institut für Bautechnik

Trade name of the construction product Injection System Hilti HIT-HY 200-R for rebar connection

Product family to which the construction product belongs

Post-installed rebar connection with Hilti injection mortar HIT-HY 200-R

tfahcsllesegneitkA itliH rerutcafunaM9494 SCHAAN FÜRSTENTUM LIECHTENSTEIN

ekreW itliH tnalp gnirutcafunaM

This European Technical Assessment contains

22 pages including 18 annexes which form an integral part of this assessment

This European Technical Assessment is issued in accordance with Regulation (EU) No 305/2011, on the basis of

Guideline for European technical approval of "Metal anchors for use in concrete", ETAG 001 Part 5: "Bonded anchors", April 2013, used as European Assessment Document (EAD) according to Article 66 Paragraph 3 of Regulation (EU) No 305/2011.

Structural Rebar connections - EC2 / EOTA TR023

Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment

Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment

Applications

Technical data

Productivity plus Productivity plus

Structural rebar connections and extensions can be safely designed like cast-in connections utilizing the design provisions provided within Eurocode 2 and EOTA TR023

*Test in cracked concrete is not required according to TR023.

Approvals

Rebar Diameter Range

ETA for rebar connections

4 hours fire resistance

T8 – T40

ETA 08/0105, ETA11/0492

Structural connections with post-installed rebarsStructural renovation / upgrades with post-installed rebarsSubstitution of misplaced / missing rebarsReinforced concrete waler with post-installed rebars

••••

Eurocode, EC2 use?

On 1st April 2015, Eurocode design standard has replaced British Standards as Singapore’s prescribed building codes for structural design (http://www.bca.gov.sg/Newsroom/pr25032013_EC.html). This also means that there is now a specific set of codes that also addresses the design method post-installed rebar and anchors.

In EC2 Clause <EN1992-1-1:2004 (E)>, it states that the design methods for post-installed rebar connections must follow EC2/Technical Report 023. And for post-installed anchors, the design must follow ETAG 001 Annex C. Thus, the design methods for the two applications are completely different.

Anchor connections - ETAG 001 Annex C / TR 029

Applications

The European Technical Approval Guideline 001 “Metal Anchors for used in Concrete” sets out the basis for assessing anchors to be used in concrete.

Wide range of fastening applications in concreteAnchoring structural steel connections (e.g. steel columns, beams)Anchoring secondary steel structures (e.g. staircases, steel ledgers)Anchoring railings / safety barriersFastening façade bracketsFastening brackets and channels

••

••••

Technical data

Approvals

Mechanical anchor diameter range

Threaded rod diameter range

Rebar diameter range

ETA for cracked or uncracked concrete

2 hours fire resistance

M6 – M24

M8 – M39

M8 – M32

Traditional Method

With Hilti Hollow Drill Bit and VC 20/40 Vacuum

Up to 60% faster!

Hilti PROFIS Rebar for design calculation for rebar connections

Cordless electric dispensers for quick, efforless injection

Injectable mortars for versatile, secure fastenings in concrete

Powerful combihammers for tough drilling jobs

Hilti PROFIS Rebar

Hilti PROFIS Anchor for design calculation for anchor connections

Service and advice to ensure the job is done right

Injectable mortars for versatile, secure fastenings in concrete

Powerful cordless combihammers for tough drilling jobs

Traditional Method

HIT-HY 200 System with HIT-Z rods

Up to 60% faster!

Hilti PROFIS anchor

,