CANVIEWER®
The CANViewer® solution is a Cloud based service which allows the user to monitor engine data either from engine on generator or engine with driven equipment. The CANViewer® Solution is the ideal solution for efficient Genset Maintenance, Remote/Periodic Genset testing, Fuel management & much more.
CANVIEWER® MOBILE
APP The remote monitoring process of an unmanned and autonomous device must be accessible at any moment from any place. The App developed inside CANViewer® for all its remote monitoring and control devices assures that the customer is in touch with his devices at a glance and has access to real time engine parameters and events.
CANVIEWER® SYSTEM The CANViewer® gateway device provides the user with full and instant access to the CANViewer® system.
PROBLEMS FACED Engine parameters and events not
available to operators & users
Data may only be available locally at the engine
Technicians and maintenance persons not able to remotely diagnose events
BENEFITS OFFERED Reduction in time taken to
diagnose events
Remote access for specialists
Datalogging
Independent of site infrastructure
CANVIEWER®
©2015 BESST PTY LTD, All Rights Reserved. (10/15)
©2015 BESST PTY LTD, All Rights Reserved. (11/15) CALL 0732194927 TODAY !
![Page 2: Besst Canviewer 28sk 011115 33](https://reader036.fdocuments.us/reader036/viewer/2022082519/5695d2531a28ab9b0299fc47/html5/thumbnails/2.jpg)
pg. 2
CANVIEWER INFORMATION SAVES YOU TROUBLE BY:
J1939 Display Unit & Mobile
App Capturing J1939 data from your engine or the engine on the generator can be difficult and time consuming. Turning that data into useful information that reduces your costs or increases your revenue can be a herculean task.
The CANViewer® Solution puts this valuable data within your reach and delivers it in a way that improves your profitability.
HOW WE DO IT?
CANViewer is an end-to-end connected asset solution that includes the on-asset hardware, international communications connections, web-based services, and strong 24/7/365 customer support. The CANViewer solution has evolved from over a decade of industry experience and it is fully integrated, so you don’t have to worry about anything except running your business. Our strength is tapping into J1939 equipment data from your Engine ECU and knowing how to turn it into useful information for your business. We can show you how we do it today, not sometime in the future, and show you how the quick and easy installation will save you money. We use a robust infrastructure for data security and an on-line web center for your tools and automated services.
SERVICES
LOCAL DISPLAY The Local display shows active events to give you critical information you can act on now, while the stored event codes give you a trail of information to follow for failure analysis
MAINTENANCE PLANNER Schedule maintenance, easily record the notes upon completion, link to your own procedures and send follow up emails with key asset information automatically included.
ALERT NOTIFICATIONS Receive automatic email and SMS notifications for alarms, fault codes or events.
MOBILE APPLICATION Have direct access to engine parameters and events in real-time via Android or iOS App.
CONFIGERABLE IO Easily configurable Digital and Analog IOs offer flexibility to control or monitor additional devices.
CLOUD BASED PORTAL Software-as-a-Service (SaaS)
cloud-based portal that allows to
run the service from Nethix’s
servers. Portal link options are
3G/GSM. LAN & WLAN.
• Local & Remote diagnostics
• Efficient site visits • Stronger customer
loyalty • Increased maintenance
contracts
• Operational Efficiency • Avoiding equipment
abuse • Proactive maintenance • Works independently
of installed IT/SCADA
CANVIEWER®
©2015 BESST PTY LTD, All Rights Reserved. (11/15) CALL 0732194927 TODAY !
![Page 3: Besst Canviewer 28sk 011115 33](https://reader036.fdocuments.us/reader036/viewer/2022082519/5695d2531a28ab9b0299fc47/html5/thumbnails/3.jpg)
pg. 3
MONITORED
INFORMATION J1939 DATA LOGGING
CANVIEWER
SPECS LOCAL DISPLAY
PHYSICAL • Polycarbonate/polyester • IP68 • SAE J1455 shock and
vibration • -40 to +85 Deg C
CANBUS • SAE J1939 Compliant
POWER • 8-32 VDC input • Sleep mode power available
GATEWAY
COMMUNICATION • 3G HSPA quad band modem • 2G GSM/GPRS dual band
modem (optional) • UMTS/HSPA, GSM/GPRS,
SMS, CSD, HCSD • Compatible with standard AT
commands 07.07 and 07.05 • Integrated SIM port • Integrated web server • HSPA/GPRS connection to a
web portal 10/100 Mbit/s RJ45 Ethernet
• USB Host A (optional) • Wi-Fi and Bluetooth (optional) INPUT/OUTPUT • 8 digital input dry contact • 2 relay outputs (0.5A, 24V) • 2 analog input (0-5V / 0-10V /
4-20mA / NTC)
POWER SOURCE • 12-24 VDC/ 1A • Other options available (48
VDC)
ACCESSORIES • XP500 - I/O modbus expansion
EVENT DIAGNOSTICS (Transmitted on Occurrence) J1939 Diagnostics Trouble Codes (DTC) Messages – no filtering SPN/FMI display with standard code definitions and descriptions
ANALOG POINTS Battery voltage Any SPN as defined above
NOTIFICATIONS Low battery voltage CAN bus failure Selected Suspect Parameter Number/Fault Mode Identifier (SPN/FMI) Any other defined alarms