Bedienungs- und Montageanleitung · table must be in exact horizontal position and be controlled...

13
Instruction Manual KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de Wall-Mounted Sink Type: TDS-5

Transcript of Bedienungs- und Montageanleitung · table must be in exact horizontal position and be controlled...

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

Wall-Mounted Sink

Type: TDS-5

Instruction Manual Wall-Mounted Sink TDS-5 Page 2 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

Content

1 General Information ................................................................................... 3 1.1 Symbols in the Instruction Manual ...................................................................... 3

2 Installation ................................................................................................... 3

3 General Use ................................................................................................. 6

4 Cleaning....................................................................................................... 6

5 General Maintenance Tips for Stainless Steel Surfaces ........................ 7 5.1 Initial Cleaning / Cleaning / Preventive Measures ............................................... 7

5.2 Cleaning Agents / Cleaning Instruments ............................................................. 7

5.2.1 Stainless Steel Polish / Stainless Steel Cleaner .............................................. 7 5.2.2 Suitable Cleaning Agents ................................................................................. 7 5.2.3 Descaling Agents ............................................................................................. 7 5.2.4 Brushes / Non-Woven Abrasives ..................................................................... 8 5.2.5 Textiles ............................................................................................................ 8

6 Heavy Duty Disposer .................................................................................. 8 6.1 Cleaning the Heavy Duty Disposer ..................................................................... 8 6.2 Releasing the Disposer Jam ............................................................................... 8

7 Water Tap .................................................................................................... 9 7.1 Application .......................................................................................................... 9 7.2 Technical Data .................................................................................................... 9 7.3 Installation ........................................................................................................... 10 7.4 Function .............................................................................................................. 10 7.5 Flow Rate Limitation ........................................................................................... 10 7.6 Maintenance ....................................................................................................... 10 7.7 Exploded Drawing and Parts .............................................................................. 11 7.8 Care Instructions ................................................................................................. 12

8 Declaration of Conformity ......................................................................... 13

Instruction Manual Wall-Mounted Sink TDS-5 Page 3 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

1 General Information

1.1 Symbols in the Instruction Manual The following symbols are used in the instruction manual:

Warning, Caution Failure to follow these instructions can lead to personal injuries, property damages and, at worst, death.

Additional information

2 Installation The base frame of the TDS-5 first has to be attached on the wall with 6 screws. The table must be in exact horizontal position and be controlled with a water level.

Attachment Points

Instruction Manual Wall-Mounted Sink TDS-5 Page 4 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

Afterwards the top part (back board with the lamp) is to be put from above on the base frame construction.

After this installation, the cable of the lamp should be connected with the cable below (black connector) The installation of the heavy-duty disposer with the bayonet catches on the sink follows. Connect the cable of heavy-duty disposer to the already installed socket.

Connect the flexible water pipes with the water connections of the building, attention to the warm and cold water pipes.

Backboard with lamp

Base frame construction

Sink

Bayonet catch

Heavy duty disposer

Disposer Waste drain tube

Instruction Manual Wall-Mounted Sink TDS-5 Page 5 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

Connect the waste drain tube to the disposer. After that, connect the waste water pipes with the connections of the building and check their water tightness.

The working table is now ready for usage. The picture below shows the description of the different switches:

Hydroaspirator (optional)

Warm- and cold water pipes

Air connection DN 200

Waste waster connection 2“

Heavy Duty Disposer Connect the air connection to the connections of thebuilding. Note: The Air exhaust ventilator is not included.

Instruction Manual Wall-Mounted Sink TDS-5 Page 6 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

3 General Use This wall mounted sink is designed for researches and dissections of mortuary. It is forbidden to use the wall mounted sink for any other purpose, e.g.:

Claiming on top of the table Put heavy loads on it

Before usage turn on the sprinkler valve and ventilation.

Attention! The heavy-duty disposer should never work without water because otherwise the crushing gear can get damaged. Before using the disposer turn on the water.

4 Cleaning The workplace is to be cleaned after every usage with clean water and afterwards if necessary with disinfectant. To remove hard contaminations don't use abrasive, only warm soapsuds.

Instruction Manual Wall-Mounted Sink TDS-5 Page 7 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

5 General Maintenance Tips for Stainless Steel Surfaces The best thing about stainless steel is that it barely requires maintenance and soiling can be removed easily.

5.1 Initial Cleaning / Cleaning / Preventive Measures After installing the stainless steel devices and/or furniture, an initial cleaning is to be performed to remove any soiling caused by storage, transport or installation works. Protective films, paper packaging or residues of adhesives are to be removed completely after having installed the devices or furniture otherwise they might lead to corrosion. For cleaning you may only use suitable cleaning agents (see below). Normally, the corresponding cleaning agent is being distributed evenly on the surface with a microfiber cloth. Tough soiling is to be treated with a soft synthetic fleece, e.g. Then remove cleaning agent stains with clear water and dry the surfaces with soft cloths. Poorly soluble residues or small scratches can be removed with a suitable non-woven abrasive.

5.2 Cleaning Agents / Cleaning Instruments Cleaning agents and instruments are t be used in accordance with the instructions of the respective producer.

5.2.1 Stainless Steel Polish / Stainless Steel Cleaner Stainless steel polish – special cleaning product and protective agent for stainless steel. 400ml spray can. Article No. 060.010.001 Shake spray can before use. Spray from approx. 25 cm distance and let it sink in for a few minutes. Then remove with a clean, dry cloth. You may sterilize and disinfect the surface if necessary afterwards. 5.2.2 Suitable Cleaning Agents Basically, alkaline cleaning agents are to be used on stainless steel parts only. Never use cleaning agents that contain hydrochloric acids or bleach. They might lead to discolorations.

5.2.3 Descaling Agents Only use off-the shelf descaling agents for stainless steel.

Instruction Manual Wall-Mounted Sink TDS-5 Page 8 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

5.2.4 Brushes / Non-Woven abrasives Brushes made of natural or plastic bristles Article Article No. Grain Size Dimension L/W

Nylon non-woven abrasive (fine grain)

060.010.002 P 1000 200 x 115mm

Nylon non-woven abrasive (coarse grain)

060.010.003 P 280 200 x 115mm

Cleaning instructions for non-woven abrasives are to be observed provided that it is a ground surface. Always clean towards the grinding pattern, never across.

5.2.5 Textiles Textiles made of natural or chemical fibers. Particularly microfibers are suitable to remove patches or fingerprints from stainless steel surfaces. Article Article No Material Dimension L/W

Microfiber cloth 060.010.005 80% Polyester 20% Polyamides

400 x 400 mm

6 Heavy Duty Disposer

6.1 Cleaning the Heavy Duty Disposer Turn off disposer and disconnect power supply Reach through the sink opening and clean underside of splash baffle and inside

upper lip of grind chamber with scouring pad Place stopper in sink opening and fill sink halfway with warm water Mix 60 ml baking soda with water. Turn disposer on and remove stopper from sink

at same time to wash away loose particles

6.2 Releasing the Disposer Jam

Instruction Manual Wall-Mounted Sink TDS-5 Page 9 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

f the motor stops while the disposer is operating, the disposer may be jammed:

Turn power and water off. Insert one end of the self-service wrenchette into the centre hole on the bottom of

the disposer. Work the wrenchette back and forth until it turns one full revolution. Remove wrenchette.

Reach into the disposer with tongs and remove objects. Allow the disposer motor to cool for 3- 5 minutes and lightly push red reset button on the disposer bottom. If the motor remains inoperative, check the service panel for tripped circuit breakers or blown fuses.

7 Water Tap Type: SP-MB-15 Article No: 060.012.045

7.1 Application Operation with unpressurised storage heaters is not possible.

7.2 Technical Data Flow pressure: min. 0,5 bar – recommended 1 – 5 bar Operating pressure: max. 10 bar Test pressure: 16 bar Flow rate at 3 bar flow pressure for shower: approx. 11 l/min for mousseur: approx. 13,5 l/min Hot water inlet temperature: max. 80°C Recommended (energy saving): 60°C Clamping length: max. 60mm If static pressure exceeds 5 bar, a pressure-reducing valve must be fitted.

Instruction Manual Wall-Mounted Sink TDS-5 Page 10 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

Avoid major pressure differences between hot and cold water supply. GROHE fittings with showers or with pull-out bath spouts/ showers are equipped with non-return valves.

7.3 Installation Flush pipes thoroughly.

7.4 Function Check connections for leaks of fitting. Turning off the mixer automatically diverts the water flow from shower to mousseur.

7.5 Flow Rate Limitation The use of flow rate limiters in combination with hydraulic instantaneous heaters is not recommended.

7.6 Maintenance Inspect and clean all components and replace if necessary. Shut off water supply for maintenance work. When installing the cartridge, ensure that the seals are correctly seated. Tighten the screws evenly and alternately. Lime scale can easily be removed from SpeedClean nozzles by simply rubbing with

the fingers. The function of the SpeedClean nozzles is guaranteed for a period of five years.

Instruction Manual Wall-Mounted Sink TDS-5 Page 11 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

7.7 Exploded Drawing and Parts

Instruction Manual Wall-Mounted Sink TDS-5 Page 12 from 13

Instruction Manual

KUGEL medical GmbH & Co. KG Phone +49 941/20 86 48-0 Hermann-Köhl-Str. 2A Fax +49 941/20 86 48-29 93049 Regensburg / GERMANY www.KUGEL-medical.de

7.8 Care Instructions

KUGEL medical GmbH & Co. KG • Hermann-Köhl-Str. 2A • 93049 Regensburg/GERMANY Phone +49/941/208648-0 • Fax +49/941/208648-29 • eMail: [email protected]

www.KUGEL-medical.de

DECLARATION OF CONFORMITY

We KUGEL medical GmbH & Co. KG Hermann-Köhl-Str. 2A DE - 93049 Regensburg / GERMANY explain in own responsibility, that the product:

Kind of equipment: Wall mounted sink

Type: TDS-5

is in compliance with following standard specifications or documents

Technical regulations: 2006/42/EG, DIN EN 954, EN 60 204-1, DIN EN 349

Regensburg, 02.05.2018 ____________________________ Authorized representative signature