WiseConn Engineering Inc. / Catalog - Components and Accessories 2.30.0.D. All rights reserved. Developed for WiseConn, distributors, partners, engineering companies, educational organizations, research and any other related companies. For more information, contact your local WiseConn representative or distributor.
4
EXP-232-MB Serial RS-232 Expansion Card
EXP-485-MB Serial RS-485 Expansion Card
EXP-2DI 2X Digital Inputs Expansion Card
EXP-SDI12 SDI12 - Serial Data Interface Expansion Card (at 1200 Baud)
22
22
22
22
EXPANSION CARDS FOR RF-X1
EXP-3AI 3X 0 to 3V Analog Inputs Expansion Card
EXP-3X420 3X 4 to 20mA Analog Inputs Expansion Card
EXP-HMI HMI Interface/5V feed Expansion Card
23
23
23
24
24
24
EXP-LATCH 1X Latch Output, 1X Digital Input Expansion Card
EXP-RELAY-LA 1X Relay Output, 1X Digital Input Expansion Card
EXP-4LATCH 4X Latch Outputs, 1X Digital Input Expansion Card
23EXP-SHT SHT Expansion Card (Temp/Hum)
RF-M1-900HP Field monitoring node with Digi XBee Pro Module - 900MHz 10
COMPONENTS
INTRODUCTION
RF-X1-900HP Field monitoring and control node with Digi XBee Pro Module - 900MHz 16
Service Plans Content plans for WOS or DropControl users. 6
PAGECODE DESCRIPTION
PAGECODE DESCRIPTION
PAGECODE DESCRIPTION
PAGEDESCRIPTION
NODES AND EXPANSION CARDS
INDEX
RF-M1-LTE-A Field monitoring node with Modem XBee3 Cellular LTE-M
RF-X1-LTE-A Field monitoring and control node with Modem XBee3 Cellular LTE-M 16
RF-X1-LTE-V Field monitoring and control node with Modem XBee3 Cellular LTE-M 16
10
RF-C1-900HP Fertigation controlling node with Digi XBee Pro Module - 900MHz 28
PAGECODE DESCRIPTION
RF-M1-LTE-V Field monitoring node with Modem XBee3 Cellular LTE-M 10
Fertigation controlling node with Digi XBee Pro Module - 900MHzand Modem XBee3 Cellular LTE-M
28RF-C1-900HP-LTE-A
RF-C1-900HP-LTE-VFertigation controlling node with Digi XBee Pro Module - 900MHzand Modem XBee3 Cellular LTE-M
28
5
ACC-ENERGY-SOLAR-1010 [W] Solar Panel for RF-X1, RF-C1 and RF-M1 nodes. Includes mounting bracket and 24 ft. cable
ACC-ENERGY-PS-110-5-2 5VDC 2A power source for RF-X1/RF-M1 Nodes
ACC-ENERGY-PS-110-24-3 24VDC 3A power source for RF-C1 Nodes
38
38
38
BATTERY, SOLAR PANEL AND POWER SUPPLY ACCESSORIES
ANTENNAS
ANTENNA EXTENSIONS, COAXIAL CABLES, AND LIGHTNING ARRESTER ACCESSORIES
EXPANSION MODULES FOR RF-C1
ACCESSORIES
ACC-PM-X1 X1 power management card 39
PAGECODE DESCRIPTION
PAGECODE DESCRIPTION
PAGECODE DESCRIPTION
ACC-ANT-900-OM22dBi SMA connector omnidirectional antenna included in RF-X1/RF-C1/RF-M1
6dBi N connector omnidirectional outdoor antenna w/brackets and 20 ft. SMA to N cable (Radio High Gain)
3dBi external cellular omnidirectional antenna for modems 40
39
39
ACC-ANT-CELL-OM3
7dBi N connector cellular omnidirectional outdoor antenna w/brackets and 20 ft. SMA to N cable for modems (Cellular High Gain) 40ACC-ANT-CELL-OM7
ACC-ANT-900-OM6-COAX-20FT
915 MHz ISM bandpass filter for XBee 900HP radios. 40ACC-ANT-FILTER
PAGECODE DESCRIPTION
41
41
41SMA to SMA extension cable for antennaACC-ANT-EXT-RF-_FT
Extension Cable Antenna 25/39 ft., SMA-N, with stand,for ACC-ANT-900-OM6.
ACC-ANT-EXT-RF-SMA-N-_FT
Lightning arrester with 4 ft. extension cableACC-COAX-LFUSE-OM2
MOD-C1-10R-10DI Expansion module for RF-C1 that provides 10 relay outputs 32
MOD-C1-12LATCH Expansion module for RF-C1 that provides 12 Latch outputs 32
ACC-ENERGY-BATT-4-13 3.7 [V] and 13 [Ah] Lithium Ion Battery for RF-X1, RF-C1 and RF-M1 nodes 38
RF-C1-LTE-A Fertigation controlling node with Modem XBee3 Cellular LTE-M 28
PAGECODE DESCRIPTION
RF-C1-LTE-V Fertigation controlling node with Modem XBee3 Cellular LTE-M 28
4dBi SMA connector omnidirectional antenna included in RF-C1-GW/ RF-M1-LTE/3G 40ACC-ANT-CELL-OM4
INTRODUCTION | CATALOG
6
INTRODUCTION | CATALOG
77
Our patented technology allows farm and irrigation managers to wirelessly monitor, control, and automate irrigation systems online in order to increase revenue, decrease expenses, and to help manage time.
Our flagship products, the WiseConn X1, M1, and C1 Nodes continuously communicate and independently
WISECONN’S TECHNOLOGYcollaborate in a wireless mesh network to monitor a wide array of field sensors and operate and control irrigation systems.
With displayed information provided by field sensors, the WiseConn “Hydraulic Logic” field intelligence allows you to create and perform precise irrigation and fertigation schedules with
confidence and run-verification. With over 6,000 nodes operating in the Western Hemisphere and over a decade of hardware engineering and software development, these powerful devices have been field-tested, helping several hundred farm operations, large and small, to safely and efficiently manage water and fertilizer distribution.
X1RF-M1Field monitoringnode
RF-X1-GWField monitoring and
control gateway node
WiseConn ServersBased in Amazon
Web Services
DropControl AppMobile and desktop appwww.dropcontrol.com
Weatherstation
Soil moistureprobe
C1RF-C1Fertigation
controlling node
Temperaturesensor
INTRODUCTION | CATALOG
8
Web Visualization - Configuration and Support- 98% Availability
Lowercase
- Configuration and Support- Basic Daily Monitoring
Tables
- Start / Stop- Basic Daily Monitoring
Tables
- Schedule Future Programs- Downloadable Reports
- Interactive Daily Monitoring Graphs
- Complete Dashboard
Storage 6 months 6 months Forever Forever
Number of Multi-profile Users 0 0 2 4 1
Number of Advisor Profile Users 0 0 0 1
Expected Web Platform Uptime 98% 90% 95% 98%
Data Availability 98% 90% 95% 98%
Alerts According to Integrator No - Emails- No Notifications
- No SMS- No Calls
- ∞ Emails- ∞ Notifications
- 50 SMS- 20 Calls
Control According to Version Remote Start / Stop(Without Programming)
Remote Start / Stop(Without Programming)
Advanced Irrigation and Fertigation
Updates Basic Security and Bugs. API Connector Upgrades
Safety Basicsand Bugs
All All
AWS Secure Backup Yes No No Yes
Remote Phone Support Yes No Yes Yes
Remote Emergency Telephone Support
No No No Extended Schedule
Creating Variables and Formulas No No No Yes
Special Mobile Site No No No DropControl Mobile App
Download Reports No No No Yes
Download Data Excel .xls Excel .xls Excel .xls Excel .xls
Basic API for Data Access According to Version Monthly Fee Per Key Monthly Fee Per Key ∞ Users 2
Full Control API According to Version No No 1 User 2
Volume Discount 0% 0% 0% > 100/25 Nodes -> 10%> 250/100 Nodes -> 15%
> 1000/500 Nodes -> 20%
Limit Questions / Day / Variable 1500/day - - -
Query Size Limit 30 days - - -
SERVICE PLANSWiseconn offers two different SaaS platforms: WOS, a basic visualization platform, and DropControl, an agricultural irrigation platform specially designed for farmers to manage all actions and sensors, and schedule irrigations through the web-based platform, or mobile app. All equipment comes with a Free Plan for life. You can also upgrade to plans with higher benefits, up to the Expert Plan, that includes usage of the DropControl mobile app with higher benefits up to the Expert Plan that include the DropControl mobile and web application.
At least one node will be charged for service / M2M plan not included / WiseConn has multicarrier options and alternatives / Switches as valve validation are not charged for service.
1 - Buy as an additional user2 - Sell as an additional user
API PLAN FREE PLAN SIMPLE PLAN EXPERT
wos +
woswos wos
INTRODUCTION | CATALOG
9
COMPONENTS Nodes, Modules, and Expansion Cards
COMPONENTS | CATALOG
10
COMPONENTS | CATALOG
11
DROPCONTROL FAMILY
Field MonitoringNode
Fertigation Control Node
Field Monitoring and Control Node
Mon
itoring
Irrigation
Con
trolA
dvan
ced Fertig
ation
COMPONENTS | CATALOG
12
Field Monitoring NodeThe M1 Field Monitoring Node is suitable for simple monitoring tasks as part of the DropControl network or on its own. It has a combination of inputs that allow you to monitor multiple devices, enabling data access in real-time and safe storage in the Cloud.
COMPONENTS | CATALOG
13
DROPCONTROL TECHNOLOGY
DEVICE FEATURES
APPLICATIONS
SPECIFICATIONS
Suitable for simple monitoring tasks & compatible with the DropControl family
• Collaborative wireless networks with 2 miles line-of-sight between nodes. • 4G / LTE cellular connection to the cloud for
synchronization.*• Solar-powered with low power consumption• Wide variety of sensors and compatible accessories.
* Restrictions apply depending on each country, consult with your local distributor.
• RF mesh networks or cellular communication.• IP65 external protection.• Autonomous energy, solar + battery.• Firmware updates via cloud software. • Support personnel set configurations and help
monitor the farm status via WOS & DropControl applications.
• Compatible with other WiseConn RF units.
• Agroclimatic variables: humidity, precipitation, temperature, wind, and radiation.
• Soil and plant health variables• Irrigation sensors: flow, pressure, and electrical
variables.• Industrial sensors with communication 4..20mA;
serial 232 or 485.
Cortex M4-F (32 bit STM32L4)
64MB Flash. 1 Year of data, up to 18 sensors every 15 minutes
5.9 x 7.9 x 3.9 [in]
2.4 [lbs]
IP65 outdoor rugged UV resistant poly -carbonate enclosure
• 20mAh idle average power draw without sensors
• 10W, 5V solar panel, 14x1x0.7 [in]• 13,000mAh Lithium-ion battery pack
• 1x Serial RS232 / RS485 (MODBUS ena-bled)
• 1x SDI12• 4x Opto-coupled Inputs (9-28V)• 2x Analog inputs (differentials) - 0-5V - 0-10V - 4-20mA
Processor
Local storage
Dimensions
Weight
Enclosure
Synchronization Power
Input-Output options
• Local RF synchronization every 5 seconds
• Sending data to the cloud every 15 minutes (can be as low as 1 minute)
INPUTS
• 1 RS232 or RS485 Serial Port• 1 SDI12 Port• 4 digital inputs• 2 analog inputs
COMPONENTS | CATALOG
14
PCB-BU-M1M1 Central unitA
ACC-ENERGY-BATT-4-133.7 [VDC] - 13 [Ah] Ion lithium batteryB
ACC-ENERGY-SOLAR-10Solar panel 10[W] - 5[VDC] C
ACC-ANT-900-OM22 [dBi] Omnidirectional antenna with SMA connectionD
BU-RF-900HPXbee Pro Digimesh 900HPE
-Solar Panel ConnectorF
Polycarbonate enclosure 5.9 x 7.9 x 3.9[in] 1G
Mounting chassis, case-fixing screws and supports for BU - M1 with plate and its screws
-H
T Bracket for node mounting 2I
8” UFL-SMA Pigtail 1J
PG9 Cable glands 3K
1
1
1
1
1
1
-
PG21 Cable gland 1L
Solar Panel mounting bracket 1M
RF-M1
Battery
Ext. Power
LEDs ON
Factory
ON
OFF
Channel
BAT
USB
JP1
FG
F2 F4 F6 F8
BU-M1 R0018Ingeniería WiseConn S.A.
Ext.Power
SerialV ATx BRx SDI GND
Digital InputsV 1 2 3 4 C GND
AnalogV1 1+ 1- GND
Analog
V2 2+ 2- GND
Power
RF Link
One Line
J1
J2
RF-1
B
A
F
I
E
J
G
H
K
D
L
C
M
ACC-ENC-X1-5.9x7.9
ACC-MOUNT-NODE-T
ACC-ANT-EXT-CELL-UFL
ACC-ENC-PG9-CGLAND
ACC-ENC-PG21-CGLAND
ACC-MOUNT-SOLAR
Front view example of a RF-M1-900HP node
Front view example of solar
panel
ID DESCRIPTION Q CODE
COMPONENTS | CATALOG
15
VERSIONS
Modem XBee3 Cellular LTE-M (with microSIM)• Standard: LTE-M• Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, Verizon, CE
Modem XBee3 Cellular LTE M (with microSIM)• Standard: LTE M• Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, AT&T, CE
Digi XBee Pro Module - 900MHz - FHSS modulation - 250mW (+ 24dBm)• Male connector for RP-SMA antenna• 2dBi antenna included (2 miles LoS range)• 10 bit DIP switch channel selection• Xbee Certifications: FCC, IC, RoHs, ANATEL, IFETEL, IDA
RF-M1-900HP
RF-M1-LTE-A
RF-M1-LTE-V
COMPONENTS | CATALOG
16
COMPATIBLE SENSORS TABLE
Variable Model - Sensor Brand Type / Dimensions / Comms RF-M1
Precipitation Davis Instruments - 7852 / 7857 Tipping bucket / 0.2mm / dry contact 4
Wind Direction and Speed Davis Instruments - 7911 Potentiometer and reed switch / ° and 1m / s / analog and digital
2
Solar radiation Davis Instruments - 6450 Total radiation / W / m2 / Voltage 2
Temperature and Humidity PCE - P18-1 RS485 1
Weather Station Spectrum Technologies - Watchdog 2900ET RS232 1
Weather Station Davis Instruments - Vantage Pro 2 Talk RS485 1
Weather Station Davis Instruments - Vantage Pro 2 Envoy RS485 1
Soil moisture Sentek - EnviroScan FDR / % / SDI12 RS232 RS485 1 2
Soil moisture Sentek - Drill&Drop FDR / % / SDI12 RS232 RS485 1 2
Soil moisture EnviroPro - EP100G / EP100GL FDR / % / SDI12 1 3
Soil moisture AquaCheck - Classic / Subsurface FDR / % / SDI12 1 4
Soil moisture Decagon -Teros12 FDR / % / SDI12 3
Soil moisture Decagon - GS3 TDR / % / SDI12 3
Soil moisture Decagon - 5TE TDR / % / SDI12 3
Soil moisture Hydrascout - HSTI SDI12 1
Pressure Detector Generic 1 Pressure switch / 10, 5 or 3 PSI / Dry contact 4 5
Pressure Detector WiseConn Pressure switch / 10, 5 or 3 PSI / Dry contact 4 5
Level Detector Dry contact level switch - Generic 1 Level switch / Dry contact 4 5
Irrigation Volume Volume pulse emitter - Generic 1 Dry contact 4 5
Irrigation Volume Bermad - TurboIR Dry contact 4 5
Irrigation Volume Bermad - Turbo Bar E Dry contact 4 5
Irrigation Volume Arad - SF15 Dry contact 4 5
Irrigation Volume Wellford Dry contact 4 5
Irrigation Volume Seametrics - AG300 Dry contact 4 5
Irrigation Volume Seametrics - AG2000 Dry contact 4 5
Irrigation Volume Seametrics - AG3000 Dry contact 4 5
Irrigation Volume McCrometer - McPropeller Dry contact 4 5
Irrigation Volume McCrometer - Mc Mag3000 Dry contact 4 5
Water pressure Generic 1 4..20mA 2 5
Water pressure Konics - TPS20 4..20mA 2 5
Water pressure Danfoss - MBS3000 4..20mA 2 5
Water pressure Danfoss - MBS1700 4..20mA 2 5
Water pressure Transducers Direct - TD1000 4..20mA 2 5
WEA
THER
SOIL
Temperature Dynamax - SAP IP-IRT Ambient and object temperature / SDI12 1
Fruit Diameter Phyto-Sensors - FI-MMi 4..20mA 2
Fruit Diameter Ecomatik - Dendrometer DF Voltage 2
Outbreak Diameter Ecomatik - Dendrometer DD-S Voltage 2
Leaf humidity Decagon Leaf wetness sensor Voltage 2
Leaf humidity Davis Leaf wetness 6420 Voltage 2PLA
NT
IRR
IGA
TIO
N
COMPONENTS | CATALOG
17
IRR
IGA
TIO
N
Water pressure Transducers Direct - TDH33 4..20mA 2 5
Water pressure Schneider Electric - XMLK100P2D23 4..20mA 2 5
Water table for wells Generic 1 4..20mA 2 5
Water table for wells Flux - 26Y 4..20mA 2 5
Reservoir or canal water level Dinel - HLM-16N Water column pressure / 1 to 200m / 4..20mA 2 5
Reservoir or canal water level Dinel - ULM-53N Ultrasound / 0.25 to 10m / 4..20mA 2 5
Reservoir or canal water level Seametrics - PS98i 4..20mA 2 5
Reservoir or canal water level Eno Scientific - Well Watch 700 4..20mA 2 5
Water pH Global Water - WQ201B 4..20mA 2 5
Water pH Ponsel - PPHRB pH - Redox - Temperature / SDI12 1
Water conductivity Ponsel - PC4EB CE - Salinity - Temperature - TDS-KCl / SDI12 1
Water pH and conductivity EMEC - pH&EC Controller LDPHCDPLUS 4..20mA 1
COMPATIBLE SENSORS TABLE
Variable Model - Sensor Brand Type / Dimensions / Comms RF-M1
1. Ask for other sensors or generics2. 1 probe 36 sensors3. 1 probe 9 depths4. 1 probe 6 depths5. They cannot be part of irrigation events
COMPONENTS | CATALOG
18
The RF-X1 unit can control, monitor, and manage multiple agricultural processes in the field, such as pump stations, fertigation, valve control, and field monitoring. Its 5 expansion ports can manage multiple combinations of inputs and outputs. The mesh network technology links nodes in the field together and has the option to designate one as a gateway to the Cloud.
Field Monitoring and Control Node
COMPONENTS | CATALOG
19
SPECIFICATIONS
Processor MSP430F5438A, Microcontroller ultra-low consumption 16bit
Local storage 1GB micro SD industrial SLC
Dimensions 5.9 x 7.9 x 3.9 [in]
Weight 2.4 [lbs]
Enclosure IP65 outdoor rugged UV resistant polycarbonate enclosure
• Local RF sync time: 0.2 seconds• Sending data to the cloud every
15 minutes(can be as low as 1 minute)
• Lag time for alarms and actions is 20 seconds max
PowerInput/Output options
5 Expansion Slots:• 4 regular• 1 dual regular/modem (for Gateway)
• 20mAh idle average power draw without sensors
• 10W, 5V solar panel, 14x1x0.7 [in]• 13,000mAh Lithium-ion battery pack
• Collaborative wireless network with 2 miles line-of-sight between nodes.
• 4G / LTE cellular connection to the cloud for synchronization.*
• Solar-powered with low power consumption• Wide variety of sensors and compatible accessories.• Patent-Pending Irrigation Management.
* Restrictions apply depending on each country, consult with your local distributor.
DROPCONTROL TECHNOLOGY
• 5 expansion slots with flexible inputs/outputs. • RF mesh networks + Cellular communication.• IP65 Enclosed Outdoor Protection.• Self-powered w/solar panel + battery.• Cloud-based scheduling, local control.• Cloud software upgrades, internet configurations,
and support.• Compatible with other WiseConn RF units.• FCC Compliant.
DEVICE FEATURES
• Valve control and monitoring.• Field monitoring on any open protocol sensor.• Pump control.• Fertigation control.• PID control.• Remote valve automation.
APPLICATIONS
Operate, monitor, and manage multiple agricultural processes in the field
Input-Output options
COMPONENTS | CATALOG
20
BU-X1X1 Central unitA
ACC-ENERGY-BATT-4-133.7 [VDC] - 13 [Ah] Ion lithium batteryB
ACC-ENERGY-SOLAR-10Solar panel 10[W] - 5[VDC] C
ACC-ANT-900-OM22 [dBi] Omnidirectional antenna with SMA connectionD
BU-RF-900HPXbee Pro Digimesh 900HPE
ACC-BU-FLASH1GB MicroSD Flash Memory, Industrial Grade (SLC)F
Polycarbonate enclosure 5.9 x 7.9 x 3.9[in] 1G
Mounting chassis, case-fixing screws and supports for BU - X1 -H
T Bracket for node mounting 2I
8” UFL-SMA Pigtail 1J
PG9 Cable glands 3K
1
1
1
1
1
1
ACC-ENC-X1-5.9x7.9
-
ACC-MOUNT-NODE-T
ACC-ANT-EXT-CELL-UFL
ACC-ENC-PG9-CGLAND
PG21 Cable gland 1L
Solar panel mounting bracket 1M
ACC-ENC-PG21-CGLAND
ACC-MOUNT-SOLAR
S
C
M
1 2 3 4 5
RF-X1
L
B
A
F
I
E
J
G
H
K
D
Front view example of a RF-X1-900HP node
Front view example of solar
panel
ID DESCRIPTION Q CODE
COMPONENTS | CATALOG
21
Modem XBee3 Cellular LTE-M (with microSIM)• Standard: LTE-M• Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, Verizon, CE
Modem XBee3 Cellular LTE M (with microSIM)• Standard: LTE M • Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, AT&T, CE
Digi XBee Pro Module - 900MHz - FHSS modulation - 250mW (+ 24dBm)• Male connector for RP-SMA antenna• 2dBi antenna included (2 miles LoS range) • 10 bit DIP switch channel selection• Xbee Certifications: FCC, IC, RoHs, ANATEL, IFETEL, IDA
RF-X1-900HP
RF-X1-GW900HP-LTE-A
RF-X1-GW900HP-LTE-V
VERSIONS
GATEWAY GATEWAY
COMPONENTS | CATALOG
2222
Expansion Cards - EXPs – allow to setup the RF-X1 Node for the technical requirements of its operating location. The EXP allows the connection of all types of sensors and/or actuators.
The EXP is the connection medium from the X1 Nodes (devices) to the processes that it will perform. As shown in the diagram, an X1 Node can support multiple EXPs; likewise, an EXP can support one or several devices (each Expansion Card has its own restrictions).
The RF-X1 has 5 slots to connect the Expansion Cards to. These cards are selected according to the type of monitoring or control capability desired.
Expansion cards for RF-X1
EXPANSIONS
COMPONENTS | CATALOG
23
EXP-___Expansion CardA
B
1
- -0.4 [in] Spacer (1), nut (1), screw (1) and washer (1) for EXP installation and fastening with BU-X1
Expansion Cards includeID DESCRIPTION Q CODE
COMPONENTS | CATALOG
24
• It has 2 optocoupler inputs• Inputs operation range: 9V to 28V (AC/DC)• AC or DC input detection, Jumper selectable • Supply Voltage: 12Vdc• Maximum Current: 125mA• Ports: 12V, In1, In2, C, GND
* In cases where the voltage to be detected comes from an external supply, C (Common) must be used as reference.
Expansion card for X1 devices: It allows sampling of up to 2 sensors with 9V to 28V (AC or DC) discrete signals. Includes a 12 VDC pull-up resistor Input.
EXP-2DI 2X Digital Inputs Expansion Card
Features• SDI-12 Connection• Up to 3 devices in bus mode• Available voltages: 5Vdc , 12Vdc• Current: 350mA (total)
*Sensor’s electric current peaks must be considered in order to avoid damaging the card’s power supply.
Expansion card for X1 devices. It allows sampling of up to 3 instruments through SDI-12 interface.
EXP-SDI12 SDI12 - Serial Data Interface Expansion Card (at 1200 Baud)
Features
• RS-232 Serial Connection• Adaptable to any serial device• Output Voltage: +12VDC• Maximum Current: 250mA
Expansion card for X1 devices. It allows the connection of Modbus RS-232 Serial interface, enabling a bidirectional communication with expansion units, instrumentation, and other devices.
EXP-232-MBSerial RS-232 Expansion Card
Features
• RS-485 Serial Connection • Adaptable to any serial device• Output Voltage: +12VDC• Maximum Current: 250mA
Expansion card for X1 devices. It allows the connection of a RS-485 Serial interface, enabling a bidirectional communication with expansion units, instrumentation, and other devices.
EXP-485-MB RS-485 Serial Expansion Card
Features
COMPONENTS | CATALOG
25
• It has 3 analog inputs• Input Voltage Range: 0 to 3Vdc (ref. GND)• Output Voltage: 3Vdc or 12Vdc• Maximum Current: 1000mA at 3Vdc, 300mA at 12Vdc• Allows up to 3 devices with the same electrical characteristics
(same supply voltage)
Expansion card for X1 devices. It allows sampling of up to 3 analog interface sensors (of the same type or with common electrical specifications).
EXP-3AI 3X 0 to 3V Analog Inputs Expansion Card
Features
• Allows monitoring up to 3 4-20mA sensors • Voltages: 16V or 24V (jumper selectable)• Maximum Current: 150mA at 24V , 250mA at 16V • Allows 3 devices with the same electrical specifications (same
supply voltage). In case of connecting devices with different specifications, its 4-20mA signal must be isolated and floating (Passive Equipment).
Expansion card for X1 devices. It allows sampling of up to 3 4..20 mA interface sensors, instrumentation, and other devices.
EXP-3X420 3X 4 to 20mA Analog Inputs Expansion Card
Features
• TTL Serial Connection - HMI Module • Voltage: 5Vdc• Current : 400mA• (3.3V) TTL Communication
Expansion card for X1 devices. It enables the connection of the HMI Expansion Module - MOD-HMI-4. Also used to feed 5Vdc into sensors that require external power or batteries.
EXP-HMI HMI Interface/5V feed Expansion Card
Features• Allows connection to Sensirion SHT1X (10,11,15)• Ports: Vdd, Sck (clock), Gnd and Data • Supply voltage: 3V• Maximum Current: 10 mA
Expansion card for X1 devices. It allows sampling of Wiseconn’s temperature and humidity sensor.
EXP-SHT SHT Expansion Card (Temp/Hum)
Features
COMPONENTS | CATALOG
26
• It has 4 outputs for Latching Solenoid control and 1 digital input (dry contact)
• Allowed Solenoids: 2 or 3 wires, 2 or 3 ways• Output Capacitance: 4700uF - 15V• Maximum cable distance (to solenoid): 300 ft• Inputs voltage range: 9V to 28V (AC/DC)
4x Solenoid Latch Outputs with 1x Digital/Dry contact input (2 slots).
EXP-4LATCH4X Latch Outputs, 1X Digital Input Expansion Card
Features
• It has 1 output for Latching Solenoid control and 1 digital input (Dry contact)
• Allowed Solenoids: 2 or 3 wires, 2 or 3 ways• Output Capacitance: 4700uF - 15V• Maximum cable distance (to solenoid): 300 ft.• Inputs voltage range: 9V to 28V (AC/DC)
Expansion card for X1 devices that controls latching solenoids (2-3 wires & 2-3 ways) with a maximum operation voltage of 15V. It also includes a discrete input for the connection of a flowmeter with pulse emitters, or any device with a discrete output.
EXP-LATCH 1X Latch Output, 1X Digital Input Expansion Card
Features
• It has a 1 Latch Relay Type Output and one optocoupler Input (Dry contact)
• Relay commutation Maximum Voltage: 220 VDC / 125 VAC• Commutation Maximum Current: 2A • Commutation Maximum Power: 60W / 62.5VA ( 24V, 2A typical)• Output Voltage/Current: 12Vdc / 125mA Maximum• Input range: 9V to 28V (AC/DC)
Expansion card for X1 devices. It allows device control via relay, which, unlike the normal option (single relay), keeps the current state with no extra energy consumption for X1 modules. This ensures greater autonomy for the device with 60W (up to 220VDC & 125 VAC or 2A) of computation power. It includes discrete input for the connection of flowmeter with pulse emitter or any device with discrete interface, as well as providing 12Vdc output voltage.
EXP-RELAY-LA1X Relay Output, 1X Digital Input Expansion Card
Features
COMPONENTS | CATALOG
27
COMPATIBLE SENSORS TABLE
Variable Model - Sensor Brand
Type / Dimensions / Comms
RF-X1
EXP
-2D
I
EXP
-3A
I
EXP
-SD
I12
EXP
-485
EXP
-485
-MB
EXP
-232
EXP
-3X4
20
EXP
-REL
AY
EXP
-REL
AY-
LATC
H
EXP
-LA
TCH
EXP
-4LA
TCH
EXP
-SH
T
Precipitation Davis Instruments - 7852 / 7857
Tipping bucket / 0.2mm / dry contact
2
Wind Direction and Speed
Davis Instruments - 7911
Potentiometer and reed switch / ° and 1m / s / analog and digital
3
Solar radiation Instruments - 6450 Total radiation / W / m2 / Voltage
3
Temperature and Humidity
Meter Group (Decagon) - VP-4
SDI12 1
Temperature and Humidity
Generic1 SHT 1
Temperature and Humidity
PCE - P18-1 RS485 1
Weather Station Davis Instruments - Vantage Pro 2 Talk
RS485 1
Weather Station Davis Instruments - Vantage Pro 2 Envoy
RS485 1
Weather Station Vaisala WXT530 SDI12 1
WEA
THER
Soil moisture Sentek - EnviroScan FDR / % / SDI12 RS232 RS485 1 2 1 2 1 2
Soil moisture Sentek - Drill&Drop FDR / % / SDI12 RS232 RS485 1 2 1 2 1 2
Soil moisture EnviroPro - EP100G / EP100GL
FDR / % / SDI12 1 3
Soil moisture AquaCheck - Classic / Subsurface
FDR / % / SDI12 1 4
Soil moisture Decagon -Teros12 FDR / % / SDI12 3
Soil moisture Decagon - GS3 TDR / % / SDI12 3
Soil moisture Decagon - 5TE TDR / % / SDI12 3
Soil moisture Watermark - Irrometer 900M
Irrometer / -KPa / 232 1 5
Soil moisture Watermark - Irrometer 200SSV6
Irrometer / -KPa / Analog 3
Soil moisture Hydrascout - HSTI SDI12 1
SOIL
Temperature Dynamax - SAP IP-IRT Ambient and object temperature / SDI12
1
Fruit Diameter Phyto-Sensors - FI-MMi
4..20mA 3
Fruit Diameter Ecomatik - Dendrometer DF
Voltage 3
Outbreak Diameter Ecomatik - Dendrometer DD-S
Voltage 3
Leaf humidity Decagon Leaf wetness sensor
Voltage 3
Leaf humidity Davis Leaf wetness 6420
Voltage 3
PLA
NT
Pressure Detector Generic1 Pressure switch / 10, 5 or 3 PSI / Dry contact
2
Pressure Detector WiseConn Pressure switch / 10, 5 or 3 PSI / Dry contact
2
Level Detector Dry contact level switch - Generic1
Level switch / Dry contact 2
IRR
IGA
TIO
N
COMPONENTS | CATALOG
28
Irrigation Volume Volume pulse emitter- Generic1
Dry contact 2
Irrigation Volume Bermad - TurboIR Dry contact 2
Irrigation Volume Bermad - Turbo Bar E Dry contact 2
Irrigation Volume Arad - SF15 Dry contact 2
Irrigation Volume Wellford Dry contact 2
Irrigation Volume Seametrics - AG300 Dry contact 2
Irrigation Volume Seametrics - AG2000 Dry contact 2
Irrigation Volume Netafim - Octave Dry contact 2
Irrigation Volume McCrometer - McPropeller
Dry contact 2
Irrigation Volume McCrometer - Mc Mag3000
Dry contact 2
Water pressure Generic1 4..20mA 3
Water pressure Konics - TPS20 4..20mA 3
Water pressure Danfoss - MBS3000 4..20mA 3
Water pressure Danfoss - MBS1700 4..20mA 3
Water pressure Seametrics - PS98i 4..20mA 3
Water pressure Transducers Direct - TD1000
4..20mA 3
Water pressure Transducers Direct - TDH33
4..20mA 3
Water pressure Schneider Electric - XMLK100P2D23
4..20mA 3
Water table for wells Generic1 4..20mA 3
Water table for wells Flux - 26Y 4..20mA 3
Reservoir or canal water level
Dinel - HLM-16N Water column pressure / 1 to 200m / 4..20mA
3
Reservoir or canal water level
Dinel - ULM-53N Ultrasound / 0.25 to 10m / 4..20mA
3
Reservoir or canal water level
Seametrics - PS98i 4..20mA 3
Reservoir or canal water level
Eno Scientific - Well Watch 700
4..20mA 3
Water pH Global Water - WQ201B 4..20mA 3
Water pH Ponsel - PPHRB pH - Redox - Temperature / SDI12
1
Water conductivity Ponsel - PC4EB CE - Salinity - Temperature - TDS-KCl / SDI12
1
Water Conductivity and pH
EMEC - pH&EC Controller LDPHCDPLUS
4..20mA 1
IRR
IGA
TIO
NCOMPATIBLE SENSORS TABLE
EXP
-2D
I
EXP
-3A
I
EXP
-SD
I12
EXP
-485
EXP
-485
-MB
EXP
-232
EXP
-3X4
20
EXP
-REL
AY
EXP
-REL
AY-
LATC
H
EXP
-LA
TCH
EXP
-4LA
TCH
EXP
-SH
T
Variable Model - Sensor Brand
Type / Dimensions / Comms
RF-X1
Electrical variables Mitsubishi - ME96SS RS485 1
ENER
GY
COMPONENTS | CATALOG
29
Dry contact output Generic1 For pump or AC valve items
1
Latch dry contact output Generic1 For pump or AC valve items
1
Latch Solenoid Output Solenoid Latch - Generic1
For actuation of Latching Solenoids valves
1 4
Pump Speed / Pressure Control
Generic1 Frequency Variator / RS485
1
Pump Speed / Pressure Control
KSB - PumpDrive 2 Frequency Variator / RS485
1
Pump Speed / Pressure Control
Mitsubishi - D700/F800 Frequency Variator / RS485
1
IRR
IGA
TIO
N C
ON
TRO
L
1. Ask for other sensors or generics2. 1 probe 36 sensors3. 1 probe 9 depths4. 1 probe 6 depths5. 1 station 7 sensors and 1 floor temperature
COMPATIBLE SENSORS TABLE
EXP
-2D
I
EXP
-3A
I
EXP
-SD
I12
EXP
-485
EXP
-485
-MB
EXP
-232
EXP
-3X4
20
EXP
-REL
AY
EXP
-REL
AY-
LATC
H
EXP
-LA
TCH
EXP
-4LA
TCH
EXP
-SH
T
Variable Model - Sensor Brand
Type / Dimensions / Comms
RF-X1
COMPONENTS | CATALOG
30
Fertigation Control NodeThe new C1 fertigation controller node is specially designed for the local control tasks at the pump station, with all the advantages of synchronization with the DropControl platform in the cloud. The patent-pending hydraulic control logic makes the local control robust and communicates with other RF-C1’s radio enabled RF-M1’s or the classic RF-X1 unit.
The direct communication with the new C1 App makes it ideal for the local control next to the pump through bluetooth communication. You can control multiple fertigation pumps and you can expand the number of inputs and outputs.
COMPONENTS | CATALOG
31
INPUTS AND OUTPUTS
• 10 digital inputs• 10 dry contact outputs• 4 analog inputs• 2 RS232 or RS485 Serial ports
• Collaborative wireless networks with 2 miles line-of-sight between nodes.
• 4G/LTE cellular connection to the cloud for synchronization.
• With energy backup and solar power options.• Wide variety of sensors and actuators available.• Filter flushing capabilites.• Patent pending hydraulic control logic
Processor ARM® 32-bit Cortex®-M4
Local Storage 1MB Flash1GB industrial micro SD SLC
Dimensions 9x9.7x4.2 [in]
Weight 3.82 [lbs]
Enclosure IP65 outdoor rugged UV resistant polycarbonate enclosure
Synchronization
• Local RF synchronization every 5 seconds• Sending data to the cloud every 15
minutes (can be as low as 1 minute)• All alarms and control actions: maximum
20 seconds
PowerInput/Output
options• 10x Digital inputs: counter (up to 40Hz) or
discrete (9 to 24 VAC/DC), configurable from the cloud
• 10x Dry contacts Outputs: 3Amp 277VAC /125VDC SPST
• 4x Independent Analog inputs: 4..20mA, 12bit resolution (or 2x differential inputs)
• 2x RS232 / RS485 serial ports. (MODBUS enabled)
• Transformer 220-110VAC at 24VDC• Optional 10W, 5V Solar panel, 14x1x0.7 [in]
(relays not functional with only solar)• 13,000mAh Lithium (Li-ion) batteries• Consumption of 40mAh at rest without
sensors/ 140 mA Gateway Version
• Up to 120 total digital inputs or outputs
• CAN communication with expansionsExpansions
DROPCONTROL TECHNOLOGY
• Local controller with web programming.• Local mesh networks + desktop & mobile.• IP65 protection for the weather.• Bluetooth for local control and irrigation monitoring.• Firmware updates via cloud software. • Support personnel set configurations and help monitor
the farm status via WOS & DropControl applications.• Compatible with all other WiseConn RF units.• Compliance with FCC and Subtel regulations.
DEVICE FEATURES
• Control and monitoring of pump stations.• Control of fertilizer injection.• pH control.• Monitoring and control of variable-frequency drive.• Remote Industrial Automation.• Local and wireless communicatin for valve control.
APPLICATIONS
SPECIFICATIONS
Designed to be the perfect pump station control unit
COMPONENTS | CATALOG
32
-Translucent top outer coverA 1
-Internal connection coverB 1
BU-C1-HMIHMI boardD
BU-C1C1 Central unitC 1
1
-Polycarbonate enclosure 9x9.7x4.2 [in]E 1
-Inner coverF 1
3.7 [VDC] - 13 [Ah] Ion lithium battery 1G ACC-ENERGY-BATT-4-13
8” UFL-SMA Pigtail 1H
2 [dBi] Omnidirectional antenna with SMA connection 1I ACC-ANT-900-OM2
PG16 Cable glands 2J
PG21 Cable glands 2K
110/220 VAC to 24VDC Power supply 1L ACC-ENERGY-PS-110-24-3
Power
OFF Line
ON Line
Battery
Ext. Power
Op. Mode
Outputs
Inputs
4.-20 mA
Serial
Factory O/C
Chanel
Status
RF-1
RF-2
4-20 mA
C1 1 2 3 4 5 1 2 3 4 5V1 C1 GND 1+V1 GND1- V AT1 BR1 AT2 BR2 GND
Outputs
C2 6 7 8 9 10 6 7 8 9 10V2 C2 GND 2+V2 GND2- S CH CL GND SLR GND VIN GND
Outputs Inputs
Inputs
4-20 mA Serial
Exp Power
A
B
E C D FG
HI
J
L
K
Front view example of RF-C1-
900HP assembly with main parts.
ACC-ANT-EXT-CELL-UFL-8in
ACC-ENC-PG16-CGLAND
ACC-ENC-PG21-CGLAND
ID DESCRIPTION Q CODE
COMPONENTS | CATALOG
33
Modem XBee3 Cellular LTE-M (with microSIM)• Standard: LTE-M• Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, Verizon, CE
Modem XBee3 Cellular LTE M (with microSIM)• Standard: LTE M • Cellular Antenna for 700-2700Mhz 4G LTE 2dBi (Monopole) • Modem Certifications: FCC, GCF, PTCRB, AT&T, CE
Digi XBee Pro Module - 900MHz - FHSS modulation - 250mW (+ 24dBm)• Male connector for RP-SMA antenna• 2dBi antenna included (2 miles LoS range)• 10 bit DIP switch channel selection• Xbee Certifications: FCC, IC, RoHs, ANATEL, IFETEL, IDA
VERSIONSRF-C1
-900HPRF-C1
-900HP-LTE-A
RF-C1-900HP-LTE-V
RF-C1-LTE-A
RF-C1-LTE-V
GATEWAY GATEWAY
COMPONENTS | CATALOG
3434
These expansion modules allow the RF-C1 to operate more inputs and outputs and for different devices, such as filters and frequency inverters. Up to 5 modules can be connected via CAN communication.
Expansion Modules for RF-C1
mod-c1
COMPONENTS | CATALOG
3535
-Hardware kit for assembly (screws)A
B
-
24 -250VAC and 24 VAC varistors
Expansion Modules Include:ID DESCRIPTION Q CODE
• Inputs: - 10x counter inputs (up to 40Hz) or discrete - 9V to 24V AC / DC - Configurable from the cloud• Outputs: - 10x dry relay contacts - 3Amp 277VAC / 125VDC SPS
MOD-C1-10R-10DIExpansion Module for RF-C1 that provides 10 relay outputs and 10 optocoupled digital inputs
Features
• It has 12 outputs for latch solenoid control• Allowed solenoids: 2 or 3 wires, 2 or 3 ways• Output Capacitance: 4700uF - 15V• Maximum cable distance (to solenoid): 328 [m] *
MOD-C1-12LATCHExpansion Module for RF-C1 that provides 12 Latch outputs
Features
COMPONENTS | CATALOG
36
COMPATIBLE SENSOR TABLE
RF-
C1
MO
D-C
1-10
R-1
0DI
MO
D-C
1-12
LATC
H
Variable Model - Sensor Brand Type / Dimensions / Comms RF-C1
Pressure Detector Generic 1 Pressure switch / 10, 5 o 3 PSI / Dry Contact 10 10
Pressure Detector WiseConn Pressure switch / 10, 5 o 3 PSI / Dry Contact 10 10
Level Detector Dry contact level switch - Generic 1 Level switch / Dry contact 10 10
Irrigation Volume Volume pulse emitter - Generic 1 Dry Contact 10 10
Irrigation Volume Bermad - TurboIR Dry Contact 10 10
Irrigation Volume Bermad - Turbo Bar E Dry Contact 10 10
Irrigation Volume Arad - SF15 Dry Contact 10 10
Irrigation Volume Wellford Dry Contact 10 10
Irrigation Volume Seametrics - AG300 Dry Contact 10 10
Irrigation Volume Seametrics - AG2000 Dry Contact 10 10
Irrigation Volume Seametrics - AG2000 Dry Contact 10 10
Irrigation Volume McCrometer - McPropeller Dry Contact 10 10
Irrigation Volume McCrometer - Mc Mag3000 Dry Contact 10 10
Water pressure Generic 1 4..20mA 4
Water pressure Konics - TPS20 4..20mA 4
Water pressure Danfoss - MBS3000 4..20mA 4
Water pressure Danfoss - MBS1700 4..20mA 4
Water pressure Transducers Direct - TD1000 4..20mA 4
Water pressure Transducers Direct - TDH33 4..20mA 4
Water pressure Schneider Electric - XMLK100P2D23 4..20mA 4
Water table for wells Generic 1 4..20mA 4
Water table for wells Flux - 26Y 4..20mA 4
Reservoir or canal water level Dinel - HLM-16N Water column pressure / 1 a 200m / 4..20mA 4
Reservoir or canal water level Dinel - ULM-53N Ultrasound / 0.25 a 10m / 4..20mA 4
Reservoir or canal water level Seametrics - PS98i 4..20mA 4
Reservoir or canal water level Eno Scientific - Well Watch 700 4..20mA 4
Water pH Global Water - WQ201B 4..20mA 4
Water Conductivity and pH EMEC - pH&EC Controller LDPHCDPLUS 4..20mA 2
Dry contact output Generic 1 For pump or AC valve items 10 2 10
Latch Solenoid Output Solenoid Latch - Generic 1 For actuation of Latching Solenoids valves 12IRR
IGAT
ION
37
Pump Speed / Pressure Control Generic 1 Frequency Variator / RS48 2
Pump Speed / Pressure Control KSB - PumpDrive 2 Frequency Variator / RS485 2
Pump Speed / Pressure Control Mitsubishi - D700/F800 Frequency Variator / RS485 2
Latch solenoid outputs for filter control Generic 1 For batch of Latch solenoid valves in filters 12
Fertilizer Injection Control Generic 1 Frequency Variator / RS485 4
IRR
IGA
TIO
N C
ON
TRO
L
1. Ask for other sensors or generics2. RF-C1 requires to be energized for relay operation
COMPATIBLE SENSOR TABLE
RF-
C1
MO
D-C
1-10
R-1
0DI
MO
D-C
1-12
LATC
H
Variable Model - Sensor Brand Type / Dimensions / Comms RF-C1
ACCESSORIES | CATALOG
38
ACCESSORIES | CATALOG
39
ACCESSORIESBatteries, Solar Panels, Power Supply,
Antennas, Cables
ACCESSORIES | CATALOG
40
ACC-ENERGYBattery, Solar Panel and Power Supply Accessories
ACC-ENERGY-SOLAR-1010 [W] Solar Panel for RF-X1/RF-C1/RF-M1 nodes. Includes mounting bracket and 24 ft. cable
ACC-ENERGY-PS-110-5-25VDC 2A power source for RF-X1/M1 Nodes
4.5x3.5x2.7 [in]
ACC-ENERGY-PS-110-24-324VDC 3A power source for RF-C1 Nodes
• Input: 220/110 [VAC]• Output: 24 [VDC]• Max Current: [3A]
ACC-ENERGY-BATT-4-133.7 [V] and 13 [Ah] Lithium Ion Battery for RF-X1/RF-C1/RF-M1 Nodes
14x1x0.7 [in]
Watt/Volt.
• 10[W] • 5 [V]
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
Specifications
• 3.7 [V]• 13 [Ah]
4.3x2.6x0.6 [in]
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
Dimensions
For
Dimensions
For
Specifications
RF-C1/RF-C1-GW
Dimensions
For
2.6x1.8x2.4 [in]• Input: 220/110 [VAC]• Output: 5 [VDC]• Max Current: [2A]
Specifications
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
Dimensions
For
ACCESSORIES | CATALOG
41
ACC-ENERGYBattery, Solar Panel and Power Supply Accessories
ACC-PM-X1Power adapter that reduces the probability of the battery being locked when it is completely discharged. Allows the connection of 2 solar panels.
ACC-ANT Antenna Accessories
For
RF-X1/RF-X1-GW
N to RPSMA
ACC-ANT-900-OM6-COAX-20FT6dBi N connector omnidirectional outdoor antenna w/brackets and 20 ft. SMA to N cable (Radio High Gain)
Connector
dBi
6
For
24x1.5 [in], cable length: 20 ft.
Dimensions and Cable Length
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
RP-SMA
ACC-ANT-900-OM22dBi SMA connector omnidirectional antenna included in RF-X1/C1/M1
Connector
dBi
2
For
3x0.4 [in], cable not included
Dimensions and Cable Length
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
ACCESSORIES | CATALOG
42
ACC-ANT Antenna Accessories
ACC-ANT-FILTER915 MHz ISM bandpass filter for XBee 900HP radios.
UFL-RPSMA Female
Connector For
RF-X1/RF-X1-GWRF-M1RF-C1/RF-C1-GW
SMA
ACC-ANT-CELL-OM33dBi external cellular omnidirectional antenna for modems
Connector
dBi
3
For
3.5x1 [in], cable length: 3 ft.
Dimensions and Cable Length
RF-X1-GWRF-C1-GWRF-M1-LTE
N to RPSMA
ACC-ANT-CELL-OM77dBi N connector cellular omnidirectional outdoor antenna w/brackets and 20 ft. SMA to N cable for modems (Cellular High Gain)
Connector
dBi
7
For
37.5x3 [in], cable length: 20 ft.
Dimensions and Cable Length
RF-X1-GWRF-C1-GWRF-M1-LTE
SMA Male
ACC-ANT-CELL-OM44dBi SMA connector omnidirectional antenna included in RF-C1-GW/ RF-M1-LTE/3G
Connector
dBi
4
For
RF-C1-GWRF-M1-LTE / 3G
ACCESSORIES | CATALOG
43
ACC-COAX Antenna Extenders, Coaxial Cables, and Lightning Rod Accessories
Extension Cable Antenna 25 ft. SMA-N, with stand,for ACC-ANT-900-OM6.
ACC-ANT-EXT-RF-SMA-N-_MT
SMA/N
Connector A / Connector B
25/39 ft.
Different Lengths
ACC-ANT-900-OM6
For
SMA to SMA extension cable for antennaACC-ANT-EXT-RF-_FT
SMA/ SMA
Connector A / Connector B
4, 10, 25 and 39 ft.
Different Lengths
ACC-ANT-900-OM2
For
Lightning arrester with 4 ft. extension cable
N
Connector
Copper Rod 4 ft. and 1”
Ground Requirement
ACC-COAX-FUSE-OM2ACC-COAX-FUSE-OM6
For
ACC-COAX-LFUSE-OM2
600 [V]
Protection
44
45
IRRIGATE