BB3 Structural Vibration Problem
Resolved Using Analytical Methods
25th International Pump Users Symposium
Michael SingerSulzer Pumps (US) Inc.Portland, OR
Joel WalkerSulzer Pumps (US) Inc.Odessa, TX
![Page 2: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/2.jpg)
2
Installation
• 3 stage BB3 type
• Water injection service (1200 GPM @ 2650 ft)
• Driven through gearbox by natural-gas engine
• 3560 to 6000 RPM continuous operating speed range
![Page 3: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/3.jpg)
3
Problem
Vibration Performance• High bearing housing and casing vibrations showed after
the pumps were relocated and put into a new service
(Ran fine in previous life)
• Same problem with 3 identical units
• Horizontal vibration (~0.6 in/sec) at or above 5200 RPM
• Not able to reach full speed (6000 RPM)
![Page 4: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/4.jpg)
4
Root Cause Analysis
PIH
Structural Resonance – Impact Testing
Impact tests show a horizontal structural resonance at
approximately 85 Hz (5100 cpm) on
pump inboard and outboard end
![Page 5: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/5.jpg)
5
Root Cause Analysis
Pump Lateral Rotordynamics
• High speed operation. (6000 RPM)
• Heavy coupling. (~100 lbs total)
• Long shaft span at drive end.
• Nearest seal is eye of suction impeller.
![Page 6: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/6.jpg)
6
Root Cause Analysis
Overhung mode critical speed (~4700 RPM)
Low damping
Large coupling orbit
![Page 7: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/7.jpg)
7
Root Cause Analysis
• Replace coupling
• Lateral stability improved
Recommendations
![Page 8: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/8.jpg)
8
Root Cause Analysis
Not every seam welded
Uncertain hold-down locations
Support Structure Modal FEA
![Page 9: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/9.jpg)
9
Root Cause Analysis
Horizontal pump mode 84Hz [5040 cpm]
Mode shape offers
clues to detuning
Support Structure Modal FEA
![Page 10: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/10.jpg)
10
Root Cause Analysis
Add gussets / struts
Box the pedestals
Predicts increase in natural frequency
136 Hz [8160 cpm]
Recommendations
![Page 11: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/11.jpg)
11
Implementation
Bracing added to all four pedestals (as piping allowed)
![Page 12: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/12.jpg)
12
Implementation
Drive-end pedestals also
'Boxed' to reduce twisting
![Page 13: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/13.jpg)
13
Implementation
Coupling Changes• Original – 48 lbs (pump-side)
• Profiled – 36 lbs (pump-side)
• Field Balanced• Entirely new
13 lbs (pump-side)
![Page 14: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/14.jpg)
14
Results
• Reduced Vibration– Original 0.60 in/sec @ 5200 RPM
– Added Struts 0.28 in/sec @ 5800 RPM
– Changed Coupling 0.19 in/sec @ 6100 RPM
• Ability to run through entire operating speed range
![Page 15: BB3 Structural Vibration Problem Resolved Using Analytical ......BB3 Structural Vibration Problem Resolved Using Analytical Methods 25 th International Pump Users Symposium Michael](https://reader030.fdocuments.us/reader030/viewer/2022011910/5f7ac1f9ce52ab033e7e8349/html5/thumbnails/15.jpg)
15
Lessons Learned
• Avoid unnecessarily heavy couplings.
• Open communication facilitates root cause analysis.
• Fix problems when found, as found.
• Relocating equipment and/or changing services –including speed range – can result in vibration issues.