Office Locations: Albany, Brisbane, Busselton, Darwin, Melbourne, Perth, Shenzhen (China), Sydney www.wge.com.au BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: Mr Daniel Barber Greenland (Sydney) Lachlan’s Line Macquarie Park Development Pty Limited Davis Demillo / Nicholas Johnson Project No. 29130-SYD-G G_RE_BASIX_003 Date: 12/07/2016 Level 6, Building B, 207 Pacific Highway, St Leonards NSW 2065 T: (02) 8484 7000 F: (02) 8484 7100 E: [email protected] W: www.wge.com.au

Transcript of BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared...

Page 1: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Office Locations: Albany, Br isbane , Busselton, Darwin, Melbourne , Perth, Shenzhen (China), Sydney www.wge.com.au

BASIX Report

Lachlan’s Line – Lot 105 North Ryde

Prepared for: Prepared by:

Mr Daniel Barber Greenland (Sydney) Lachlan’s Line Macquarie Park Development Pty Limited

Davis Demillo / Nicholas Johnson Project No. 29130-SYD-G

G_RE_BASIX_003

Date:

12/07/2016

Level 6, Building B, 207 Pacific Highway, St Leonards NSW 2065

T: (02) 8484 7000 F: (02) 8484 7100 E: [email protected] W: www.wge.com.au

Page 2: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Revision

REVISION \\WGE- SYD -F S-01\PROJECTS \29130\PROJECT D OCUMENTATION \SUSTAINABILITY\BASIX \LOT 105\ CURRENT_160617\G_RE_BASIX _003.D OCX

REVISION DATE COMMENT APPROVED BY

2 12/07/2016 DA Issue NCJ

1 20/06/2016 DA Issue NCJ

0 14/04/2016 Preliminary for Client Review NCJ

Qualifications to this Report

The following qualifications apply to this report:

Information has been based on our understanding of the proposed building and documentation provided, as noted.

This report outlines the scope of works required for BASIX compliance only. Additional requirements such as civil/stormwater, façade design and/or acoustic requirements should be coordinated with the relevant design

consultants.

As this project involves no detailed design or site supervision by Wood & Grieve Engineers, we advise that we will not prepare a Safety in Design report for this project. As detailed in our scope of work we will review the Safety in Design report prepared by the project designer and make comment as appropriate. We confirm that the responsibility for complying with the requirements of the state OH&S legislation remains with the project designer in conjunction with the project team and the client.

Disclaimer The energy models prepared for BASIX thermal comfort compliance provides an estimate of the base building’s energy performance. This estimate is based on a necessarily simplified and idealised version of the building that does not and cannot fully represent all of the intricacies of the building and its operation. As a result, the energy model results only

represent an interpretation of the potential performance of the building. No guarantee or warrantee of building performance in practice can be based on energy modelling results alone.

PREPARED BY: ENGINEER

DAVIS DEMILLO WOOD & GRIEVE ENGINEERS Sustainability Engineer

APPROVED BY: PROJECT ENGINEER

NICHOLAS JOHNSON WOOD & GRIEVE ENGINEERS Sustainability Section Manager / Project Engineer

Page 3: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Executive Summary

EXECUTIVE SUMMARY

Executive Summary In summary, we can confirm the following outcome of the BASIX analysis:

It has been determined that the proposed buildings will achieve a BASIX Certification with the following scores:

Water: 40% (Required target: 40%)

Thermal Comfort: pass (Required target: pass)

Energy: 22% (Required target: 20%)

BASIX certificates are included within Appendix B.

Further information regarding the thermal comfort and building fabric specification has been outlined within Section 3.0 (Design Specification) of this report. Note this specification detail forms the basis of BASIX compliance and therefore must be documented within the project design/specification in order to achieve CC approval.

Our assessment works have been conducted based on the Architectural Plans drawings dated, 7 July 2016, prepared and issued by TURNER.

Page 4: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

INTRODUCTION

1.0 Introduction Wood and Grieve Engineers have completed a Building Sustainability Index (BASIX) assessment for the proposed multi-unit residential development located at future Lot 105, Lachlan’s Line, North Ryde. Based on information provided to

date and the nominated architectural drawings (7 July 2016) the following outcome has been achieved:

Water: 40% (Required target: 40%)

Thermal Comfort: pass (Required target: pass)

Energy: 22% (Required target: 20%)

Design Target

Based on the relevant Local Environmental Plan, Development Control Plan (DCP) – Ryde City Council and the NSW Apartment Design Guide (formerly SEPP65), we understand that the project is required to demonstrate BASIX compliance in support of the application development approval (Class 2 Multi-unit residential dwellings).

Building Sustainability Index (BASIX)

BASIX is implemented under the Environmental Planning and Assessment Act and applies to all residential dwelling types within NSW. BASIX forms both part of the development application and building certification process within the

state of NSW. BASIX sets water and greenhouse gas reduction targets relative to the NSW average benchmark for per person potable water consumption & greenhouse gas emissions within the residential sector. BASIX also sets the minimum

performance levels for thermal comfort of the dwelling and replaces the NCC Energy Efficiency benchmarks within the state of NSW. Thermal comfort levels are assessed via a simulation method in accordance with the NatHERS House Energy Rating protocol.

Development Overview

The proposed development includes:

Two (2) buildings in total A maximum of 308 new residential dwellings based on the Architectural plans referenced in this report. A total of 223 residential car parking spaces

Page 5: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

THERMAL COMFORT DESIGN ASSESSMENT

2.0 Thermal Comfort Design Assessment The thermal comfort aspect of this assessment was conducted using the FirstRate5 Thermal Performance Assessment Software, which assesses the thermal performance of a Class 1 or Class 2 dwelling in accordance with the requirements

of National House Energy Rating Scheme (NatHERS) scheme as stated in the BASIX Thermal Comfort Protocol.

Compliance requires that the average area adjusted heating and cooling loads are below or equal to the average area adjusted heating and cooling loads calculated by BASIX. In addition, individual dwellings must also meet descriptive targets as defined by BASIX. Based on the information received to date, the development average area adjusted heating and cooling loads were found to be as noted in the table below.

Lot 105 – Lachlan’s Line Heating Load (MJ/m2/year) Cooling Load (MJ/m2/year)

BASIX Maximum Average 51 45 Average – All Buildings 42.7 23.8

Note: Full summary of NatHERS Thermal Performance Results is attached within Appendix A. We have also included a floor plan with nominated apartment numbers as they were not available on the architectural plans.

Energy Modelling Software

Thermal comfort compliance has been demonstrated via the simulation method within BASIX. Wood & Grieve Engineers have conducted energy simulations utilising FirstRate5 software which is approved under the BASIX Thermal Comfort Protocol (May 2016).

Energy Modelling Limitations

The energy modelling results obtained from the FirstRate5 software provides an estimate of the base building energy

performance only. This estimate is based upon a simplified and idealised version of the building that does not fully comply with the intricacies of a building and its operation. As a result the energy mode represents an interpretation of the potential building performance only. Several dependent factors will affect the actual operational performance of the building, including local climate variation, building occupant behaviour, construction technique and building services commissioning. No guarantee or warrantee of building performance in practice can be based on energy modelling results alone.

Page 6: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

THERMAL COMFORT DESIGN ASSESSMENT

Design Documentation

The following assessment is based on all architectural drawings received from TURNER, dated 7 July 2016 and associated design notes, including:

DA-110-B01 GA Plans Basement 01; DA-110-B02 GA Plans Basement 02;

DA-110-B03 GA Plans Basement 03; DA-112-000 Building J Floor Plans Ground Level Plan;

DA-112-001 Building J Floor Plans Level 1 Plan; DA-112-002 Building J Floor Plans Level 2 Plan;

DA-112-003 Building J Floor Plans Level 3 Plan;

DA-112-004 Building J Floor Plans Level 4 Plan;

DA-112-005 Building J Floor Plans Level 5 Plan; DA-112-006 Building J Floor Plans Level 6 Plan;

DA-112-007 Building J Floor Plans Level 7 Plan; DA-112-008 Building J Floor Plans Level 8 Plan;

DA-112-009 Building J Floor Plans Level 9 Plan; DA-112-010 Building J Floor Plans Level 10 Plan;

DA-112-011 Building J Floor Plans Level 11 Plan; DA-112-012 Building J Floor Plans Level 12 Plan;

DA-112-013 Building J Floor Plans Level 13 Plan;

DA-112-014 Building J Floor Plans Level 14 Plan;

DA-112-015 Building J Floor Plans Level 15 Plan; DA-112-016 Building J Floor Plans Level 16 Plan;

DA-113-000 Building J Floor Plans Ground Level Plan;

DA-113-001 Building J Floor Plans Level 1 Plan; DA-113-002 Building J Floor Plans Level 2 Plan;

DA-113-003 Building J Floor Plans Level 3 Plan;

DA-113-004 Building J Floor Plans Level 4 Plan;

DA-113-005 Building J Floor Plans Level 5 Plan; DA-113-006 Building J Floor Plans Level 6 Plan;

DA-113-007 Building J Floor Plans Level 7 Plan; DA-113-008 Building J Floor Plans Level 8 Plan;

DA-113-009 Building J Floor Plans Level 9 Plan;

DA-113-010 Building J Floor Plans Level 10 Plan;

DA-113-011 Building J Floor Plans Level 11 Plan; DA-113-012 Building J Floor Plans Level 12 Plan;

DA-113-013 Building J Floor Plans Level 13 Plan;

DA-113-014 Building J Floor Plans Level 14 Plan;

DA-250-001 East Elevation; DA-250-002 West Elevation;

DA-250-003 North Elevation; DA-250-004 South Elevation;

DA-250-005 North Section East Elevation;

DA-250-006 South Section

Notes: 1. Changes to the design drawings and specifications will affect the outcome of this assessment and potentially

the certification of the proposed building works. Any changes nominated by the design team are to be

immediately communicated to Wood & Grieve Engineers as it may affect the outcome of the BASIX Compliance. We recommend any design changes be reviewed and approved prior to documentation.

Page 7: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

DESIGN SPECIFICATION

3.0 Design Specification BASIX Compliant Design Specification

Design Specification:

External Walls:

A minimum of R2.5 insulation added to Concrete Block Walls to give a total R-Value of R2.8.

Walls to internal Corridor:

A minimum of R1.5 insulation added to partition walls between apartments, and corridors or non-conditioned internal zones to give a total R-Value of R1.8.

Internal Walls to Adjoining Apartment:

As the adjoining apartment is considered a conditioned space there is no thermal insulation requirement for this wall. Therefore the insulation to this wall shall be as per acoustic requirements.

Ceilings:

We have assumed floor to ceiling heights of minimum 2700mm to living zones.

Roof Type:

A minimum of R3.0 insulation to be added to all apartments below roof or where there is an exposed concrete terrace/balcony area above (total R-value R3.2).

Suspended Floor Slabs:

Add R1.0 insulation to underside of suspended concrete slabs for enclosed floor levels between conditioned and

internal non-conditioned spaces (i.e. enclosed carpark or non-air conditioned lobbies below).

Add R2.0 insulation to underside of conditioned zones where the suspended concrete floor slab is exposed (i.e. external open space below).

Windows

The glazing specification U-Value =4.48 W/m2.K and SHGC of 0.55 (Low E, single glazed, 6mm clear with standard aluminium frame or equivalent), is required for fixed and operable windows in the following apartments:

Building J: 110, 210, 310, 410, 510, 610, 710, 809, 909, 1009, 1109, 1209, 1309, 1408, 1508, 1601, 1608

Building K: 101, 110, 201, 301, 401, 501, 601, 701, 801, 901, 1001, 1101, 1109, 1201, 1209, 1301, 1309, 1401, 1402, 1408, 1409

The following glazing specification is required for all remaining fixed and operable windows:

U-Value of 6.07 W/m2.K and an SHGC of 0.65 (Single Glazed, 6mm Clear with standard aluminium frame or equivalent)

All windows have been specified with weather-strips to prevent air infiltration when closed. This is standard compliance with AS2047.

Note: The thermal performance values for all windows detailed above are for glass and framing system combined.

Page 8: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

DESIGN SPECIFICATION

Design Specification:

Floor Coverings

The following design specifications have been included within the NatHERS Assessments:

Carpet to all bedrooms

Timber floor boards to the living spaces; and

Ceramic tiles to the bathrooms/wet areas.

Air Leakage

Kitchen Exhaust will be via a ducted range-hood to the external façade or roof.

All bathrooms and ensuite exhaust to be via a ducted exhaust fan to external façade or roof.

Back-draft dampers must be installed to prevent air infiltration.

Alternative Water Supply

No rainwater harvesting tank is required for BASIX compliance within the site.

For stormwater requirements, please refer to the Civil Engineer’s detailed specifications.

Hot Water System

A central hot water system (storage) for each building (2) has been specified within the BASIX Certificate.

Domestic Hot Water pipework is required to have minimum R0.6 insulation.

It should be noted that a less efficient hot water system will affect the rating of the BASIX Water Target.

Mechanical Ventilation Systems:

Common Areas:

Car park – Mechanical Supply & Exhaust with carbon monoxide monitor + VSD fan

Garbage Rooms – Ventilation Exhaust Only

Fire Pump Room/Switch Room/Comms Room – Ventilation Supply Only

Fire Control Centre – Air Conditioning

Corridors /Fire Stairs/Storage/Other Plant Rooms – No mechanical ventilation

Dwelling Air-Conditioning Systems:

Reverse cycle air-conditioning (Single Phase) for all dwellings (living zones).

Minimum EER ratings – Cooling 3.0-3.5, Heating 3.0-3.5

Lighting:

Common Areas:

Compact Fluorescent or LED lighting with motion sensor and/or time-clock control.

Dwellings:

Dedicated fluorescent or LED Lamps.

Page 9: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

DESIGN SPECIFICATION

Design Specification:

Appliance Specifications:

The following minimum energy performance specifications have been included within the BASIX assessment:

Energy Star Ratings:

Gas cooktop and electric ovens to all dwellings.

Dishwasher – not specified

Clothes Dryer – not specified

Clothes Washer – not specified

Compliance Note: A reduction in the quality of any of these appliances will affect the energy aspect of the BASIX rating. Client to confirm which appliances are to be included within base-building design.

Fixtures & Fittings:

We note that fixtures with the following WELS ratings have been included in the BASIX Assessment:

Common Areas (as applicable) & all dwellings:

3 Star WELS rated Showerheads (>6.0 but<= 7.5 l/min) 4 Star WELS Toilets

6 Star WELS Kitchen taps 6 Star WELS Bathroom taps Dishwasher – not specified

We note a reduction in the quality of these appliances will affect the water aspect of the BASIX rating.

Page 10: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lachlan’s Line – Lot 105

BASIX CERTIFICATION DETAIL

4.0 BASIX Certification Detail Project Summary

Project Name Lot 105 Lachlan’s Line Street Address 25-27 Epping Road, Macquarie Park

Local Government Area Ryde City Council

Plan Type / Number DP1207368 Lot No# 1

Section No# -

No. of Residential Buildings 2

No. of units in Residential Flat Buildings 308 No. of multi-dwelling houses 0

No. of single dwelling houses 0

BASIX Certificate No# 717601M Project Score

Water 40%

Thermal Comfort Pass

Energy 22%

Page 11: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Appendix A – Energy Modelling Results

Appendix A

Page 12: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lot 105 Lachlans LineFirst Rate Energy Rating Assessment

Building JJOB NO. 29130-SYD-G-1

Rev 0

CLIMATE ZONEAVERAGE ENERGY

INTENSITY ( MJ/m2)

AVERAGE STAR

RATINGMINIMUM STAR RATING

No. Of Rated

Apartment

Total Number of

Apartments

56 66.9 5.0 3.5 163.0 163

Level Apt No. Apt Type Bedrooms A/C Area (m2) Non A/C Area (m

2) Heating - MJ/m

2Cooling - MJ/m

2Energy Rating - MJ/m

2 Star Rating Total Energy - MJ

G01 J04_G 2 69.4 3.7 40.90 48.70 89.6 3.9 6218.24

G02 J05_G 2 63.7 4.4 48.20 57.80 106.0 4.3 6752.20

G03 J11_G 2 63.7 3.8 46.50 57.20 103.7 3.5 6605.69

G04 J12_G 1 44.2 6.5 36.50 45.40 81.9 4.2 3619.98

G05 J12_H_G 1 44.2 6.5 33.30 45.60 78.9 4.3 3487.38

J0101 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0102 J01_F 2 69.1 3.6 20.90 42.90 63.8 5.1 4408.58

J0103 J02_F 2 70.0 3.6 37.40 31.40 68.8 4.8 4816.00

J0104 J03_F1 1 50.0 3.5 35.00 35.40 70.4 4.7 3520.00

J0105 J03_H_F1 1 50.0 3.5 43.90 36.20 80.1 4.3 4005.00

J0106 J03_F2 1 50.0 3.5 34.80 36.20 71.0 4.7 3550.00

J0107 J03_H_F2 1 50.0 3.5 43.80 36.60 80.4 4.2 4020.00

J0108 J06_F 1 52.8 3.7 41.40 39.20 80.6 4.2 4255.68

J0109 J07_F 2 60.7 8.2 47.10 26.40 73.5 4.5 4461.45

J0110 J08_F 1 50.4 6.2 58.30 26.50 84.8 4.1 4273.92

J0111 J08_H_F 1 50.4 6.2 59.00 32.90 91.9 3.8 4631.76

J0201 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0202 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0203 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0204 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0205 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0206 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0207 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0208 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0209 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0210 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0211 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0301 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0302 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0303 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0304 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0305 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0306 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0307 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0308 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0309 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0310 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0311 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0401 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0402 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0403 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0404 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0405 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0406 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0407 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0408 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0409 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0410 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0411 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0501 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0502 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0503 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0504 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0505 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0506 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0507 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0508 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0509 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0510 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0511 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0601 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0602 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0603 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0604 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0605 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0606 J03 1 50.0 3.5 43.60 18.20 61.8 5.2 3090.00

J0607 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0608 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0609 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0610 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0611 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0701 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0702 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0703 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0704 J03_P1 1 50.0 3.5 41.60 17.80 59.4 5.4 2970.00

J0705 J03_H 1 50.0 3.5 49.70 19.50 69.2 4.8 3460.00

J0706 J03_P2 1 50.0 3.5 41.10 17.90 59.0 5.4 2950.00

J0707 J03_H_P1 1 50.0 3.5 51.10 18.50 69.6 4.8 3480.00

J0708 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0709 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0710 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0711 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0801 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0802 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0803 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0804 J09_H_F 2 70.8 3.6 31.90 25.70 57.6 5.5 4078.08

J0805 J13_F 2 71.7 4.2 25.50 24.70 50.2 6.0 3599.34

J0806 J09_F 2 70.8 3.6 31.00 26.80 57.8 5.5 4092.24

J0807 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0808 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0809 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0810 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J0901 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J0902 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J0903 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J0904 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J0905 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J0906 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J0907 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J0908 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J0909 J08 1 50.4 6.2 54.00 13.50 67.5 4.9 3402.00

J0910 J08_H 1 50.4 6.2 57.70 17.30 75.0 4.5 3780.00

J1001 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1002 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

Ground

Level 1

Level 2

Level 3

Level 9

Level 4

Level 5

Level 6

Level 7

Level 8

29130_Building J_First Rate Brief and Results_160620.xlsm

Page 13: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

J1003 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1004 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1005 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1006 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1007 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1008 J07_R 2 60.7 8.2 63.00 14.70 77.7 4.3 4716.39

J1009 J08_P 1 50.4 6.2 58.20 12.40 70.6 4.7 3558.24

J1010 J08_H_P 1 50.4 6.2 62.40 16.50 78.9 4.3 3976.56

J1101 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1102 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J1103 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1104 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1105 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1106 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1107 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1108 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J1109 J10 2 69.9 3.6 64.70 12.00 76.7 4.4 5361.33

J1201 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1202 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J1203 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1204 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1205 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1206 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1207 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1208 J07 2 60.7 8.2 49.40 18.10 67.5 4.9 4097.25

J1209 J10 2 69.9 3.6 64.70 12.00 76.7 4.4 5361.33

J1301 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1302 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J1303 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1304 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1305 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1306 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1307 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1308 J07_R 2 60.7 8.2 63.00 14.70 77.7 4.3 4716.39

J1309 J10 2 69.9 3.6 64.70 12.00 76.7 4.4 5361.33

J1401 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1402 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J1403 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1404 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1405 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1406 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1407 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1408 J10 2 69.9 3.6 64.70 12.00 76.7 4.4 5361.33

J1501 J04 2 69.4 3.7 55.90 28.40 84.3 4.1 5850.42

J1502 J01 2 69.1 3.6 28.30 26.30 54.6 5.7 3772.86

J1503 J02 2 70.0 3.6 41.50 27.40 68.9 4.8 4823.00

J1504 J09_H 2 70.8 3.6 29.30 25.00 54.3 5.7 3844.44

J1505 J13 2 71.7 4.2 28.30 22.50 50.8 6.0 3642.36

J1506 J09 2 70.8 3.6 28.20 25.20 53.4 5.8 3780.72

J1507 J06 1 52.8 3.7 41.50 24.50 66.0 4.9 3484.80

J1508 J10 2 69.9 3.6 64.70 12.00 76.7 4.4 5361.33

J1601 J04_R 2 69.4 3.7 48.40 24.90 73.3 4.5 5087.02

J1602 J01_R 2 69.1 3.6 45.40 20.60 66.0 4.9 4560.60

J1603 J02_R 2 70.0 3.6 57.10 23.10 80.2 4.3 5614.00

J1604 J09_R 2 70.8 3.6 37.10 22.00 59.1 5.4 4184.28

J1605 J13_R 2 71.7 4.2 37.70 21.30 59.0 5.4 4230.30

J1606 J09_H_R 2 70.8 3.6 37.80 21.00 58.8 5.4 4163.04

J1607 J06_R 1 52.8 3.7 61.50 28.80 90.3 3.9 4767.84

J1608 J10_R 2 69.9 3.6 61.40 11.90 74.6 4.0 5214.54

Level 13

Level 14

Level 15

Level 16

Level 10

Level 11

Level 12

29130_Building J_First Rate Brief and Results_160620.xlsm

Page 14: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Lot 105 Lachlans Line

First Rate Energy Rating Assessment

Building KJOB NO. 29130-SYD-G

Rev 0

CLIMATE ZONEAVERAGE ENERGY

INTENSITY ( MJ/m2)

AVERAGE STAR

RATINGMINIMUM STAR RATING

No. Of Rated

Apartment

Total Number of

Apartments

56 65.8 5.1 3.8 145.0 145

Level Apt No. Apt Type Bedrooms A/C Area (m2) Non A/C Area (m

2) Heating - MJ/m

2Cooling - MJ/m

2Energy Rating - MJ/m

2 Star Rating Total Energy - MJ

K0101 K01_F 1 50.4 3.7 59.40 32.80 92.2 3.8 4646.88

K0102 K02_F 2 69.3 3.6 48.20 37.30 85.5 4.0 5925.15

K0103 K03_F 2 71.9 3.9 22.40 30.70 53.1 5.8 3817.89

K0104 K04_F 1 46.0 3.6 18.10 58.50 76.6 4.4 3523.60

K0105 K05_F 1 50.0 3.5 35.20 36.30 71.5 4.6 3575.00

K0106 K05_H_F 1 50.0 3.5 43.00 33.50 76.5 4.4 3825.00

K0107 K05_F 1 50.0 3.5 35.20 36.30 71.5 4.6 3575.00

K0108 K05_H_F 1 50.0 3.5 43.00 33.50 76.5 4.4 3825.00

K0109 K06_F 2 68.4 3.9 49.50 41.50 91.0 3.9 6224.40

K0110 K11_F 1 51.0 3.7 64.50 25.10 89.6 3.9 4569.60

K0201 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0202 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0203 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0204 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0205 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0206 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0207 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0208 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0209 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0210 K07_F 1 33.5 3.6 19.70 20.20 39.9 6.9 1336.65

K0211 K08_F 1 45.6 3.6 47.20 27.50 74.7 4.5 3406.32

K0301 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0302 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0303 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0304 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0305 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0306 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0307 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0308 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0309 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0310 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0311 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0401 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0402 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0403 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0404 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0405 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0406 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0407 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0408 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0409 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0410 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0411 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0501 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0502 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0503 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0504 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0505 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0506 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0507 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0508 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0509 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0510 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0511 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0601 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0602 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0603 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0604 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0605 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0606 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0607 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0608 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0609 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0610 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0611 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0701 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0702 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0703 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0704 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0705 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0706 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0707 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0708 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0709 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0710 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0711 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0801 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0802 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0803 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0804 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0805 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0806 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0807 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0808 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0809 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0810 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0811 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K0901 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K0902 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K0903 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K0904 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K0905 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0906 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0907 K05 1 50.0 3.5 43.20 16.80 60.0 5.3 3000.00

K0908 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K0909 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K0910 K07 1 33.5 3.6 20.80 15.00 35.8 7.2 1199.30

K0911 K08 1 45.6 3.6 48.60 18.50 67.1 4.9 3059.76

K1001 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K1002 K02 2 69.3 3.6 55.30 21.90 77.2 4.4 5349.96

K1003 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K1004 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K1005 K05_P1 1 50.0 3.5 43.00 16.50 59.5 5.4 2975.00

K1006 K05_H 1 50.0 3.5 49.50 18.40 67.9 4.8 3395.00

K1007 K05_P2 1 50.0 3.5 42.50 17.00 59.5 5.4 2975.00

Level 1

Level 2

Level 3

Level 9

Level 7

Level6

Level 5

Level 4

Level 8

Level 10

29130_Building K_First Rate Results_160616.xlsm

Page 15: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

K1008 K05_H_P1 1 50.0 3.5 50.80 18.50 69.3 4.8 3465.00

K1009 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K1010 K07_P 1 33.5 3.6 26.40 14.80 41.2 6.8 1380.20

K1011 K08_P 1 45.6 3.6 56.00 18.30 74.3 4.5 3388.08

K1101 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K1102 K02_B 2 69.3 3.6 64.50 28.20 92.7 3.8 6424.11

K1103 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K1104 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K1105 K09_H_F 2 70.8 3.6 27.00 24.70 51.7 5.9 3660.36

K1106 K12_F 2 71.7 4.2 28.30 22.70 51.0 6.0 3656.70

K1107 K09_F 2 70.8 3.6 25.90 25.60 51.5 5.9 3646.20

K1108 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K1109 K10 2 70.1 3.7 52.50 18.30 70.8 4.7 4963.08

K1201 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K1202 K02_B 2 69.3 3.6 64.50 28.20 92.7 3.8 6424.11

K1203 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K1204 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K1205 K09_H 2 70.8 3.6 26.80 25.10 51.9 5.9 3674.52

K1206 K12 2 71.7 4.2 28.60 22.80 51.4 5.9 3685.38

K1207 K09 2 70.8 3.6 26.20 25.30 51.5 5.9 3646.20

K1208 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K1209 K10 2 70.1 3.7 52.50 18.30 70.8 4.7 4963.08

K1301 K01 1 50.4 3.7 54.90 23.40 78.3 4.3 3946.32

K1302 K02_B 2 69.3 3.6 64.50 28.20 92.7 3.8 6424.11

K1303 K03 2 71.9 3.9 19.60 15.80 35.4 7.2 2545.26

K1304 K04 1 46.0 3.6 24.20 47.20 71.4 4.7 3284.40

K1305 K09_H 2 70.8 3.6 26.80 25.10 51.9 5.9 3674.52

K1306 K12 2 71.7 4.2 28.60 22.80 51.4 5.9 3685.38

K1307 K09 2 70.8 3.6 26.20 25.30 51.5 5.9 3646.20

K1308 K06 2 68.4 3.9 53.80 28.60 82.4 4.2 5636.16

K1309 K10 2 70.1 3.7 52.50 18.30 70.8 4.7 4963.08

K1401 K01_R 1 50.4 3.7 64.50 18.80 83.3 4.1 4198.32

K1402 K02_R 2 69.3 3.6 53.90 23.70 88.5 3.9 6133.05

K1403 K03_R 2 71.9 3.9 32.80 15.10 47.9 6.2 3444.01

K1404 K04_R 1 46.0 3.6 34.60 45.50 80.1 4.3 3684.60

K1405 K09_H_R 2 70.8 3.6 36.20 21.80 58.0 5.5 4106.40

K1406 K12_R 2 71.7 4.2 36.30 20.20 56.5 5.6 4051.05

K1407 K09_R 2 70.8 3.6 35.00 22.40 57.4 5.5 4063.92

K1408 K06_R 2 68.4 3.9 46.70 21.10 67.8 4.9 4637.52

K1409 K10_R 2 70.1 3.7 62.60 20.40 83.0 4.1 5818.30

Level 14

Level 13

Level 12

Level 11

29130_Building K_First Rate Results_160616.xlsm

Page 16: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Appendix B – BASIX Certificate

Appendix B

Page 17: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Building Sustainability Index www.basix.nsw.gov.au

Multi Dwelling

Certificate number: 717601M

This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated18/09/2014 published by the Department. This document is available atwww.basix.nsw.gov.au

SecretaryDate of issue: Friday, 08 July 2016To be valid, this certificate must be lodged within 3 months of the date of issue.

Project summaryProject name Lachlans Line - Lot 105

Street address 25-27 Epping Road Macquarie Park 2113

Local Government Area Ryde City Council

Plan type and plan number deposited 1207368

Lot no. 1

Section no. -

No. of residential flat buildings 2

No. of units in residential flat buildings 308

No. of multi-dwelling houses 0

No. of single dwelling houses 0

Project score

Water 40 Target 40

Thermal Comfort Pass Target Pass

Energy 22 Target 20

Certificate Prepared by

Name / Company Name: Wood and Grieve Engineers

ABN (if applicable): 97137999609

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 1/37

Page 18: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Description of project

Project addressProject name Lachlans Line - Lot 105

Street address 25-27 Epping Road Macquarie Park 2113

Local Government Area Ryde City Council

Plan type and plan number deposited 1207368

Lot no. 1

Section no. -

Project typeNo. of residential flat buildings 2

No. of units in residential flat buildings 308

No. of multi-dwelling houses 0

No. of single dwelling houses 0

Site detailsSite area (m²) 2822

Roof area (m²) 2088.93

Non-residential floor area (m²) 745.0

Residential car spaces 223

Non-residential car spaces 0

Common area landscapeCommon area lawn (m²) 0.0

Common area garden (m²) 0.0

Area of indigenous or low water usespecies (m²)

0.0

Assessor detailsAssessor number VIC/13/1513

Certificate number 15130052

Climate zone 56

Project score

Water 40 Target 40

Thermal Comfort Pass Target Pass

Energy 22 Target 20

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 2/37

Page 19: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Description of project

The tables below describe the dwellings and common areas within the project

Residential flat buildings - Block J, 163 dwellings, 17 storeys above ground

G01 2 69.4 3.7 0.0 0.0 G02 2 63.7 4.4 0.0 0.0 G03 2 63.7 3.8 0.0 0.0 G04 1 44.2 6.5 0.0 0.0

G05 1 44.2 6.5 0.0 0.0 J0101 2 69.4 3.7 0.0 0.0 J0102 2 69.1 3.6 0.0 0.0 J0103 2 70.0 3.6 0.0 0.0

J0104 1 50.0 3.5 0.0 0.0 J0105 1 50.0 3.5 0.0 0.0 J0106 1 50.0 3.5 0.0 0.0 J0107 1 50.0 3.5 0.0 0.0

J0108 1 52.8 3.7 0.0 0.0 J0109 2 60.7 8.2 0.0 0.0 J0110 1 50.4 6.2 0.0 0.0 J0111 1 50.4 6.2 0.0 0.0

J0201 2 69.4 3.7 0.0 0.0 J0202 2 69.1 3.6 0.0 0.0 J0203 2 70.0 3.6 0.0 0.0 J0204 1 50.0 3.5 0.0 0.0

J0205 1 50.0 3.5 0.0 0.0 J0206 1 50.0 3.5 0.0 0.0 J0207 1 50.0 3.5 0.0 0.0 J0208 1 52.8 3.7 0.0 0.0

J0209 2 60.7 8.2 0.0 0.0 J0210 1 50.4 6.2 0.0 0.0 J0211 1 50.4 6.2 0.0 0.0 J0301 2 69.4 3.7 0.0 0.0

J0302 2 69.1 3.6 0.0 0.0 J0303 2 70.0 3.6 0.0 0.0 J0304 1 50.0 3.5 0.0 0.0 J0305 1 50.0 3.5 0.0 0.0

J0306 1 50.0 3.5 0.0 0.0 J0307 1 50.0 3.5 0.0 0.0 J0308 1 52.8 3.7 0.0 0.0 J0309 2 60.7 8.2 0.0 0.0

J0310 1 50.4 6.2 0.0 0.0 J0311 1 50.4 6.2 0.0 0.0 J0401 2 69.4 3.7 0.0 0.0 J0402 2 69.1 3.6 0.0 0.0

J0403 2 70.0 3.6 0.0 0.0 J0404 1 50.0 3.5 0.0 0.0 J0405 1 50.0 3.5 0.0 0.0 J0406 1 50.0 3.5 0.0 0.0

J0407 1 50.0 3.5 0.0 0.0 J0408 1 52.8 3.7 0.0 0.0 J0409 2 60.7 8.2 0.0 0.0 J0410 1 50.4 6.2 0.0 0.0

J0411 1 50.4 6.2 0.0 0.0 J0501 2 69.4 3.7 0.0 0.0 J0502 2 69.1 3.6 0.0 0.0 J0503 2 70.0 3.6 0.0 0.0

J0504 1 50.0 3.5 0.0 0.0 J0505 1 50.0 3.5 0.0 0.0 J0506 1 50.0 3.5 0.0 0.0 J0507 1 50.0 3.5 0.0 0.0

J0508 1 52.8 3.7 0.0 0.0 J0509 2 60.7 8.2 0.0 0.0 J0510 1 50.4 6.2 0.0 0.0 J0511 1 50.4 6.2 0.0 0.0

J0601 2 69.4 3.7 0.0 0.0 J0602 2 69.1 3.6 0.0 0.0 J0603 2 70.0 3.6 0.0 0.0 J0604 1 50.0 3.5 0.0 0.0

J0605 1 50.0 3.5 0.0 0.0 J0606 1 50.0 3.5 0.0 0.0 J0607 1 50.0 3.5 0.0 0.0 J0608 1 52.8 3.7 0.0 0.0

J0609 2 60.7 8.2 0.0 0.0 J0610 1 50.4 6.2 0.0 0.0 J0611 1 50.4 6.2 0.0 0.0 J0701 2 69.4 3.7 0.0 0.0

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 3/37

Page 20: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

J0702 2 69.1 3.6 0.0 0.0 J0703 2 70.0 3.6 0.0 0.0 J0704 1 50.0 3.5 0.0 0.0 J0705 1 50.0 3.5 0.0 0.0

J0706 1 50.0 3.5 0.0 0.0 J0707 1 50.0 3.5 0.0 0.0 J0708 1 52.8 3.7 0.0 0.0 J0709 2 60.7 8.2 0.0 0.0

J0710 1 50.4 6.2 0.0 0.0 J0711 1 50.4 6.2 0.0 0.0 J0801 2 69.4 3.7 0.0 0.0 J0802 2 69.1 3.6 0.0 0.0

J0803 2 70.0 3.6 0.0 0.0 J0804 2 70.8 3.6 0.0 0.0 J0805 2 71.7 4.2 0.0 0.0 J0806 2 70.8 3.6 0.0 0.0

J0807 1 52.8 3.7 0.0 0.0 J0808 2 60.7 8.2 0.0 0.0 J0809 1 50.4 6.2 0.0 0.0 J0810 1 50.4 6.2 0.0 0.0

J0901 2 69.4 3.7 0.0 0.0 J0902 2 69.1 3.6 0.0 0.0 J0903 2 70.0 3.6 0.0 0.0 J0904 2 70.8 3.6 0.0 0.0

J0905 2 71.7 4.2 0.0 0.0 J0906 2 70.8 3.6 0.0 0.0 J0907 1 52.8 3.7 0.0 0.0 J0908 2 60.7 8.2 0.0 0.0

J0909 1 50.4 6.2 0.0 0.0 J0910 1 50.4 6.2 0.0 0.0 J1001 2 69.4 3.7 0.0 0.0 J1002 2 69.1 3.6 0.0 0.0

J1003 2 70.0 3.6 0.0 0.0 J1004 2 70.8 3.6 0.0 0.0 J1005 2 71.7 4.2 0.0 0.0 J1006 2 70.8 3.6 0.0 0.0

J1007 1 52.8 3.7 0.0 0.0 J1008 2 60.7 8.2 0.0 0.0 J1009 1 50.4 6.2 0.0 0.0 J1010 1 50.4 6.2 0.0 0.0

J1101 2 69.4 3.7 0.0 0.0 J1102 2 69.1 3.6 0.0 0.0 J1103 2 70.0 3.6 0.0 0.0 J1104 2 70.8 3.6 0.0 0.0

J1105 2 71.7 4.2 0.0 0.0 J1106 2 70.8 3.6 0.0 0.0 J1107 1 52.8 3.7 0.0 0.0 J1108 2 60.7 8.2 0.0 0.0

J1109 2 69.9 3.6 0.0 0.0 J1201 2 69.4 3.7 0.0 0.0 J1202 2 69.1 3.6 0.0 0.0 J1203 2 70.0 3.6 0.0 0.0

J1204 2 70.8 3.6 0.0 0.0 J1205 2 71.7 4.2 0.0 0.0 J1206 2 70.8 3.6 0.0 0.0 J1207 1 52.8 3.7 0.0 0.0

J1208 2 60.7 8.2 0.0 0.0 J1209 2 69.9 3.6 0.0 0.0 J1301 2 69.4 3.7 0.0 0.0 J1302 2 69.1 3.6 0.0 0.0

J1303 2 70.0 3.6 0.0 0.0 J1304 2 70.8 3.6 0.0 0.0 J1305 2 71.7 4.2 0.0 0.0 J1306 2 70.8 3.6 0.0 0.0

J1307 1 52.8 3.7 0.0 0.0 J1308 2 60.7 8.2 0.0 0.0 J1309 2 69.9 3.6 0.0 0.0 J1401 2 69.4 3.7 0.0 0.0

J1402 2 69.1 3.6 0.0 0.0 J1403 2 70.0 3.6 0.0 0.0 J1404 2 70.8 3.6 0.0 0.0 J1405 2 71.7 4.2 0.0 0.0

J1406 2 70.8 3.6 0.0 0.0 J1407 1 52.8 3.7 0.0 0.0 J1408 2 69.9 3.6 0.0 0.0 J1501 2 69.4 3.7 0.0 0.0

J1502 2 69.1 3.6 0.0 0.0 J1503 2 70.0 3.6 0.0 0.0 J1504 2 70.8 3.6 0.0 0.0 J1505 2 71.7 4.2 0.0 0.0

J1506 2 70.8 3.6 0.0 0.0 J1507 1 52.8 3.7 0.0 0.0 J1508 2 69.9 3.6 0.0 0.0 J1601 2 69.4 3.7 0.0 0.0

J1602 2 69.1 3.6 0.0 0.0 J1603 2 70.0 3.6 0.0 0.0 J1604 2 70.8 3.6 0.0 0.0 J1605 2 71.7 4.2 0.0 0.0

J1606 2 70.8 3.6 0.0 0.0 J1607 1 52.8 3.7 0.0 0.0 J1608 2 69.9 3.6 0.0 0.0

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 4/37

Page 21: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Residential flat buildings - Block K, 145 dwellings, 15 storeys above ground

K0101 1 50.4 3.7 0.0 0.0 K0102 2 69.3 3.6 0.0 0.0 K0103 2 71.9 3.9 0.0 0.0 K0104 1 46.0 3.6 0.0 0.0

K0105 1 50.0 3.5 0.0 0.0 K0106 1 50.0 3.5 0.0 0.0 K0107 1 50.0 3.5 0.0 0.0 K0108 1 50.0 3.5 0.0 0.0

K0109 2 68.4 3.9 0.0 0.0 K0110 1 51.0 3.7 0.0 0.0 K0201 1 50.4 3.7 0.0 0.0 K0202 2 69.3 3.6 0.0 0.0

K0203 2 71.9 3.9 0.0 0.0 K0204 1 46.0 3.6 0.0 0.0 K0205 1 50.0 3.5 0.0 0.0 K0206 1 50.0 3.5 0.0 0.0

K0207 1 50.0 3.5 0.0 0.0 K0208 1 50.0 3.5 0.0 0.0 K0209 2 68.4 3.9 0.0 0.0 K0210 1 33.5 3.6 0.0 0.0

K0211 1 45.6 3.6 0.0 0.0 K0301 1 50.4 3.7 0.0 0.0 K0302 2 69.3 3.6 0.0 0.0 K0303 2 71.9 3.9 0.0 0.0

K0304 1 46.0 3.6 0.0 0.0 K0305 1 50.0 3.5 0.0 0.0 K0306 1 50.0 3.5 0.0 0.0 K0307 1 50.0 3.5 0.0 0.0

K0308 1 50.0 3.5 0.0 0.0 K0309 2 68.4 3.9 0.0 0.0 K0310 1 33.5 3.6 0.0 0.0 K0311 1 45.6 3.6 0.0 0.0

K0401 1 50.4 3.7 0.0 0.0 K0402 2 69.3 3.6 0.0 0.0 K0403 2 71.9 3.9 0.0 0.0 K0404 1 46.0 3.6 0.0 0.0

K0405 1 50.0 3.5 0.0 0.0 K0406 1 50.0 3.5 0.0 0.0 K0407 1 50.0 3.5 0.0 0.0 K0408 1 50.0 3.5 0.0 0.0

K0409 2 68.4 3.9 0.0 0.0 K0410 1 33.5 3.6 0.0 0.0 K0411 1 45.6 3.6 0.0 0.0 K0501 1 50.4 3.7 0.0 0.0

K0502 2 69.3 3.6 0.0 0.0 K0503 2 71.9 3.9 0.0 0.0 K0504 1 46.0 3.6 0.0 0.0 K0505 1 50.0 3.5 0.0 0.0

K0506 1 50.0 3.5 0.0 0.0 K0507 1 50.0 3.5 0.0 0.0 K0508 1 50.0 3.5 0.0 0.0 K0509 2 68.4 3.9 0.0 0.0

K0510 1 33.5 3.6 0.0 0.0 K0511 1 45.6 3.6 0.0 0.0 K0601 1 50.4 3.7 0.0 0.0 K0602 2 69.3 3.6 0.0 0.0

K0603 2 71.9 3.9 0.0 0.0 K0604 1 46.0 3.6 0.0 0.0 K0605 1 50.0 3.5 0.0 0.0 K0606 1 50.0 3.5 0.0 0.0

K0607 1 50.0 3.5 0.0 0.0 K0608 1 50.0 3.5 0.0 0.0 K0609 2 68.4 3.9 0.0 0.0 K0610 1 33.5 3.6 0.0 0.0

K0611 1 45.6 3.6 0.0 0.0 K0701 1 50.4 3.7 0.0 0.0 K0702 2 69.3 3.6 0.0 0.0 K0703 2 71.9 3.9 0.0 0.0

K0704 1 46.0 3.6 0.0 0.0 K0705 1 50.0 3.5 0.0 0.0 K0706 1 50.0 3.5 0.0 0.0 K0707 1 50.0 3.5 0.0 0.0

K0708 1 50.0 3.5 0.0 0.0 K0709 2 68.4 3.9 0.0 0.0 K0710 1 33.5 3.6 0.0 0.0 K0711 1 45.6 3.6 0.0 0.0

K0801 1 50.4 3.7 0.0 0.0 K0802 2 69.3 3.6 0.0 0.0 K0803 2 71.9 3.9 0.0 0.0 K0804 1 46.0 3.6 0.0 0.0

K0805 1 50.0 3.5 0.0 0.0 K0806 1 50.0 3.5 0.0 0.0 K0807 1 50.0 3.5 0.0 0.0 K0808 1 50.0 3.5 0.0 0.0

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 5/37

Page 22: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

K0809 2 68.4 3.9 0.0 0.0 K0810 1 33.5 3.6 0.0 0.0 K0811 1 45.6 3.6 0.0 0.0 K0901 1 50.4 3.7 0.0 0.0

K0902 2 69.3 3.6 0.0 0.0 K0903 2 71.9 3.9 0.0 0.0 K0904 1 46.0 3.6 0.0 0.0 K0905 1 50.0 3.5 0.0 0.0

K0906 1 50.0 3.5 0.0 0.0 K0907 1 50.0 3.5 0.0 0.0 K0908 1 50.0 3.5 0.0 0.0 K0909 2 68.4 3.9 0.0 0.0

K0910 1 33.5 3.6 0.0 0.0 K0911 1 45.6 3.6 0.0 0.0 K1001 1 50.4 3.7 0.0 0.0 K1002 2 69.3 3.6 0.0 0.0

K1003 2 71.9 3.9 0.0 0.0 K1004 1 46.0 3.6 0.0 0.0 K1005 1 50.0 3.5 0.0 0.0 K1006 1 50.0 3.5 0.0 0.0

K1007 1 50.0 3.5 0.0 0.0 K1008 1 50.0 3.5 0.0 0.0 K1009 2 68.4 3.9 0.0 0.0 K1010 1 33.5 3.6 0.0 0.0

K1011 1 45.6 3.6 0.0 0.0 K1101 1 50.4 3.7 0.0 0.0 K1102 2 69.3 3.6 0.0 0.0 K1103 2 71.9 3.9 0.0 0.0

K1104 1 46.0 3.6 0.0 0.0 K1105 2 70.8 3.6 0.0 0.0 K1106 2 71.7 4.2 0.0 0.0 K1107 2 70.8 3.6 0.0 0.0

K1108 2 68.4 3.9 0.0 0.0 K1109 2 70.1 3.7 0.0 0.0 K1201 1 50.4 3.7 0.0 0.0 K1202 2 69.3 3.6 0.0 0.0

K1203 2 71.9 3.9 0.0 0.0 K1204 1 46.0 3.6 0.0 0.0 K1205 2 70.8 3.6 0.0 0.0 K1206 2 71.7 4.2 0.0 0.0

K1207 2 70.8 3.6 0.0 0.0 K1208 2 68.4 3.9 0.0 0.0 K1209 2 70.1 3.7 0.0 0.0 K1301 1 50.4 3.7 0.0 0.0

K1302 2 69.3 3.6 0.0 0.0 K1303 2 71.9 3.9 0.0 0.0 K1304 1 46.0 3.6 0.0 0.0 K1305 2 70.8 3.6 0.0 0.0

K1306 2 71.7 4.2 0.0 0.0 K1307 2 70.8 3.6 0.0 0.0 K1308 2 68.4 3.9 0.0 0.0 K1309 2 70.1 3.7 0.0 0.0

K1401 1 50.4 3.7 0.0 0.0 K1402 2 69.3 3.6 0.0 0.0 K1403 2 71.9 3.9 0.0 0.0 K1404 1 46.0 3.6 0.0 0.0

K1405 2 70.8 3.6 0.0 0.0 K1406 2 71.7 4.2 0.0 0.0 K1407 2 70.8 3.6 0.0 0.0 K1408 2 68.4 3.9 0.0 0.0

K1409 2 70.1 3.7 0.0 0.0

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 6/37

Page 23: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Description of project

The tables below describe the dwellings and common areas within the project

Common areas of unit building - Block J

Common area Floor area (m²) Common area Floor area (m²)

Lift car (No.1) - Lift car (No.2) -

Common areas of unit building - Block K

Common area Floor area (m²) Common area Floor area (m²) Common area Floor area (m²)

Lift car (No.3) - Lift car (No.4) - Lift car (No.5) -

Common areas of the development (non-building specific)

Common area Floor area (m²) Common area Floor area (m²) Common area Floor area (m²)

Car park area (L2) 2179.7 Car park area (L1) 2174.5 Car park area (L0) 1941.6

Switch room/Comms Room/Services 143.24 Garbage rooms 260.8 Fire Control Centre 10.5

Fire Stairs 940.9 Lobbies/Corridors 2257.2

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 7/37

Page 24: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Schedule of BASIX commitments

1. Commitments for Residential flat buildings - Block J

(a) Dwellings(i) Water(ii) Energy(iii) Thermal Comfort

(b) Common areas and central systems/facilities(i) Water(ii) Energy

2. Commitments for Residential flat buildings - Block K

(a) Dwellings(i) Water(ii) Energy(iii) Thermal Comfort

(b) Common areas and central systems/facilities(i) Water(ii) Energy

3. Commitments for multi-dwelling houses

4. Commitments for single dwelling houses

5. Commitments for common areas and central systems/facilities for the development (non-building specific)(i) Water(ii) Energy

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 8/37

Page 25: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Schedule of BASIX commitments

The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.

1. Commitments for Residential flat buildings - Block J

(a) Dwellings

(i) Water Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.

(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).

(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it.

(d) The applicant must install an on demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "HW recirculation or diversion" column of the table below.

(e) The applicant must install:

(aa) a hot water diversion system to all showers, kitchen sinks and all basins in the dwelling, where indicated for a dwelling inthe "HW recirculation or diversion" column of the table below; and

(bb) a separate diversion tank (or tanks) connected to the hot water diversion systems of at least 100 litres. The applicantmust connect the hot water diversion tank to all toilets in the dwelling.

(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below.

(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both).

(g) The pool or spa must be located as specified in the table.

(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling inthe table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 9/37

Page 26: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Fixtures Appliances Individual pool Individual spa

Dwellingno.

Allshower-heads

All toiletflushingsystems

Allkitchentaps

Allbathroomtaps

HWrecirculationor diversion

Allclotheswashers

All dish-washers

Volume(maxvolume)

Poolcover

Poollocation

Poolshaded

Volume(maxvolume)

Spacover

Spashaded

Alldwellings

3 star (>6 but <=7.5L/min)

4 star 6 star 6 star - - - - - - - - - -

Alternative water source

Dwelling no. Alternative watersupply systems

Size Configuration Landscapeconnection

Toiletconnection(s)

Laundryconnection

Pooltop-up

Spa top-up

None - - - - - - - -

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.

(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.

(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table.

(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system is specified in the table for "Living areas" or "Bedroom areas", then no systems may be installed inany such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide for day/nightzoning between living areas and bedrooms.

(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 10/37

Page 27: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.

(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:

(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and

(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump.

(h) The applicant must install in the dwelling:

(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below;

(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and

(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table.

(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "wellventilated".

Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system

Dwellingno.

Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control

Alldwellings

central hot watersystem 1

individual fan, ductedto façade or roof

manual switch on/off individual fan, ductedto façade or roof

manual switch on/off individual fan, ductedto façade or roof

manual switch on/off

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 11/37

Page 28: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

G04,G05,J0104,J0105,J0106,J0107,J0108,J0110,J0111,J0204,J0205,J0206,J0207,J0208,J0210,J0211,J0304,J0305,J0306,J0307,J0308,J0310,J0311,J0404,J0405,J0406,J0407,J0408,J0410,J0411,J0504,J0505,J0506,J0507,J0508,J0510,J0511,J0604,J0605,

1-phaseairconditioningEER 3.0 - 3.5

- 1-phaseairconditioningEER 3.0 - 3.5

- 1 1 yes yes yes yes 0 -

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 12/37

Page 29: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

J0606,J0607,J0608,J0610,J0611,J0704,J0705,J0706,J0707,J0708,J0710,J0711,J0807,J0809,J0810,J0907,J0909,J0910,J1007,J1009,J1010,J1107,J1207,J1307,J1407,J1507,J1607

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 13/37

Page 30: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

G01,G02,G03,J0101,J0102,J0103,J0109,J0201,J0202,J0203,J0209,J0301,J0302,J0303,J0309,J0401,J0402,J0403,J0409,J0501,J0502,J0503,J0509,J0601,J0602,J0603,J0609,J0701,J0702,J0703,J0709,J0801,J0802,J0803,J0804,J0805,J0806,J0808,J0901,

1-phaseairconditioningEER 3.0 - 3.5

- 1-phaseairconditioningEER 3.0 - 3.5

- 2 1 yes yes yes yes 0 -

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 14/37

Page 31: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

J0902,J0903,J0904,J0905,J0906,J0908,J1001,J1002,J1003,J1004,J1005,J1006,J1008,J1101,J1102,J1103,J1104,J1105,J1106,J1108,J1109,J1201,J1202,J1203,J1204,J1205,J1206,J1208,J1209,J1301,J1302,J1303,J1304,J1305,J1306,J1308,J1309,J1401,J1402,

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 15/37

Page 32: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

J1403,J1404,J1405,J1406,J1408,J1501,J1502,J1503,J1504,J1505,J1506,J1508,J1601,J1602,J1603,J1604,J1605,J1606,J1608

Individual pool Individual spa Appliances & other efficiency measures

Dwellingno.

Pool heatingsystem

Timer Spa heatingsystem

Timer Kitchencooktop/oven

Refrigerator Wellventilatedfridgespace

Dishwasher Clotheswasher

Clothesdryer

Indoor orshelteredclothesdrying line

Privateoutdoor orunshelteredclothesdrying line

Alldwellings

- - - - gas cooktop &electric oven

- - - - - - -

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 16/37

Page 33: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(iii) Thermal Comfort Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.

(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.

(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.

(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.

(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.

(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.

(g) Where there is an in-slab heating or cooling system, the applicant must:

(aa) Install insulation with an R-value of not less than 1.0 around the vertical edges of the perimeter of the slab; or

(bb) On a suspended floor, install insulation with an R-value of not less than 1.0 underneath the slab and around the verticaledges of the perimeter of the slab.

(h) The applicant must construct the floors and walls of the development in accordance with the specifications listed in the tablebelow.

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

G01 40.9 48.7

G02 48.2 57.8

G03 46.5 57.2

G04 36.5 45.4

G05 33.3 45.6

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 17/37

Page 34: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

J0102 20.9 42.9

J0103 37.4 31.4

J0104 35.0 35.4

J0105 43.9 36.2

J0106 34.8 36.2

J0107 43.8 36.6

J0108 41.4 39.2

J0109 47.1 26.4

J0110 58.3 26.5

J0111 59.0 32.9

J0704 41.6 17.8

J0706 41.1 17.9

J0707 51.1 18.5

J0804 31.9 25.7

J0805 25.5 24.7

J0806 31.0 26.8

J1009 58.2 12.4

J1010 62.4 16.5

J1601 48.4 24.9

J1602 45.4 20.6

J1603 57.1 23.1

J1604 37.1 22.0

J1605 37.7 21.3

J1606 37.8 21.0

J1607 61.5 28.8

J1608 61.4 11.9

J1008, J1308 63.0 14.7

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 18/37

Page 35: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

J1109, J1209, J1309, J1408,J1508

64.7 12.0

J0904, J1004, J1104, J1204,J1304, J1404, J1504

29.3 25.0

J0905, J1005, J1105, J1205,J1305, J1405, J1505

28.3 22.5

J0906, J1006, J1106, J1206,J1306, J1406, J1506

28.2 25.2

J0210, J0310, J0410, J0510,J0610, J0710, J0809, J0909

54.0 13.5

J0211, J0311, J0411, J0511,J0611, J0711, J0810, J0910

57.7 17.3

J0204, J0206, J0304, J0306,J0404, J0406, J0504, J0506,J0604, J0606

43.6 18.2

J0209, J0309, J0409, J0509,J0609, J0709, J0808, J0908,J1108, J1208

49.4 18.1

J0205, J0207, J0305, J0307,J0405, J0407, J0505, J0507,J0605, J0607, J0705

49.7 19.5

J0202, J0302, J0402, J0502,J0602, J0702, J0802, J0902,J1002, J1102, J1202, J1302,J1402, J1502

28.3 26.3

J0203, J0303, J0403, J0503,J0603, J0703, J0803, J0903,J1003, J1103, J1203, J1303,J1403, J1503

41.5 27.4

J0208, J0308, J0408, J0508,J0608, J0708, J0807, J0907,J1007, J1107, J1207, J1307,J1407, J1507

41.5 24.5

All other dwellings 55.9 28.4

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 19/37

Page 36: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(b) Common areas and central systems/facilities

(i) Water Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table.

(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.

(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable.

(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table.

(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table.

(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table.

Common area Showerheads rating Toilets rating Taps rating Clothes washers rating

All commonareas

no common facility no common facility no common facility no common laundry facility

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.

(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.

(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 20/37

Page 37: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Common area ventilation system Common area lighting

Common area Ventilation system type Ventilation efficiencymeasure

Primary type of artificiallighting

Lighting efficiencymeasure

Lighting controlsystem/BMS

Lift car (No.1) - - light-emitting diode connected to lift call button Yes

Lift car (No.2) - - light-emitting diode connected to lift call button Yes

Central energy systems Type Specification

Central hot water system (No. 1) gas-fired storage(manifolded)

Piping insulation (ringmain & supply risers):(b) Piping internal to building: R0.6 (~25 mm)

Lift (No. 1) gearless traction with V V VF motor

Number of levels (including basement): 20

Lift (No. 2) gearless traction with V V VF motor

Number of levels (including basement): 20

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 21/37

Page 38: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

2. Commitments for Residential flat buildings - Block K

(a) Dwellings

(i) Water Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.

(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).

(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it.

(d) The applicant must install an on demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "HW recirculation or diversion" column of the table below.

(e) The applicant must install:

(aa) a hot water diversion system to all showers, kitchen sinks and all basins in the dwelling, where indicated for a dwelling inthe "HW recirculation or diversion" column of the table below; and

(bb) a separate diversion tank (or tanks) connected to the hot water diversion systems of at least 100 litres. The applicantmust connect the hot water diversion tank to all toilets in the dwelling.

(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below.

(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both).

(g) The pool or spa must be located as specified in the table.

(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling inthe table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 22/37

Page 39: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Fixtures Appliances Individual pool Individual spa

Dwellingno.

Allshower-heads

All toiletflushingsystems

Allkitchentaps

Allbathroomtaps

HWrecirculationor diversion

Allclotheswashers

All dish-washers

Volume(maxvolume)

Poolcover

Poollocation

Poolshaded

Volume(maxvolume)

Spacover

Spashaded

Alldwellings

3 star (>6 but <=7.5L/min)

4 star 6 star 6 star - - - - - - - - - -

Alternative water source

Dwelling no. Alternative watersupply systems

Size Configuration Landscapeconnection

Toiletconnection(s)

Laundryconnection

Pooltop-up

Spa top-up

None - - - - - - - -

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.

(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.

(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table.

(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system is specified in the table for "Living areas" or "Bedroom areas", then no systems may be installed inany such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide for day/nightzoning between living areas and bedrooms.

(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 23/37

Page 40: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.

(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:

(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and

(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump.

(h) The applicant must install in the dwelling:

(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below;

(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and

(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table.

(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "wellventilated".

Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system

Dwellingno.

Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control

Alldwellings

central hot watersystem 2

individual fan, ductedto façade or roof

manual switch on/off individual fan, ductedto façade or roof

manual switch on/off individual fan, ductedto façade or roof

manual switch on/off

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 24/37

Page 41: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

K0102,K0103,K0109,K0202,K0203,K0209,K0302,K0303,K0309,K0402,K0403,K0409,K0502,K0503,K0509,K0602,K0603,K0609,K0702,K0703,K0709,K0802,K0803,K0809,K0902,K0903,K0909,K1002,K1003,K1009,K1102,K1103,K1105,K1106,K1107,K1108,K1109,K1202,K1203,

1-phaseairconditioningEER 3.0 - 3.5

- 1-phaseairconditioningEER 3.0 - 3.5

- 2 1 yes yes yes yes 0 -

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 25/37

Page 42: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

K1205,K1206,K1207,K1208,K1209,K1302,K1303,K1305,K1306,K1307,K1308,K1309,K1402,K1403,K1405,K1406,K1407,K1408,K1409

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 26/37

Page 43: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

K0101,K0104,K0105,K0106,K0107,K0108,K0110,K0201,K0204,K0205,K0206,K0207,K0208,K0210,K0211,K0301,K0304,K0305,K0306,K0307,K0308,K0310,K0311,K0401,K0404,K0405,K0406,K0407,K0408,K0410,K0411,K0501,K0504,K0505,K0506,K0507,K0508,K0510,K0511,

1-phaseairconditioningEER 3.0 - 3.5

- 1-phaseairconditioningEER 3.0 - 3.5

- 1 1 yes yes yes yes 0 -

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 27/37

Page 44: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

K0601,K0604,K0605,K0606,K0607,K0608,K0610,K0611,K0701,K0704,K0705,K0706,K0707,K0708,K0710,K0711,K0801,K0804,K0805,K0806,K0807,K0808,K0810,K0811,K0901,K0904,K0905,K0906,K0907,K0908,K0910,K0911,K1001,K1004,K1005,K1006,K1007,K1008,K1010,

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 28/37

Page 45: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Cooling Heating Artificial lighting Natural lighting

Dwellingno.

living areas bedroomareas

living areas bedroomareas

No. ofbedrooms&/or study

No. ofliving &/ordiningrooms

Eachkitchen

Allbathrooms/toilets

Eachlaundry

Allhallways

No. ofbathrooms&/ortoilets

Mainkitchen

K1011,K1101,K1104,K1201,K1204,K1301,K1304,K1401,K1404

Individual pool Individual spa Appliances & other efficiency measures

Dwellingno.

Pool heatingsystem

Timer Spa heatingsystem

Timer Kitchencooktop/oven

Refrigerator Wellventilatedfridgespace

Dishwasher Clotheswasher

Clothesdryer

Indoor orshelteredclothesdrying line

Privateoutdoor orunshelteredclothesdrying line

Alldwellings

- - - - gas cooktop &electric oven

- - - - - - -

(iii) Thermal Comfort Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.

(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.

(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 29/37

Page 46: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(iii) Thermal Comfort Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.

(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.

(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.

(g) Where there is an in-slab heating or cooling system, the applicant must:

(aa) Install insulation with an R-value of not less than 1.0 around the vertical edges of the perimeter of the slab; or

(bb) On a suspended floor, install insulation with an R-value of not less than 1.0 underneath the slab and around the verticaledges of the perimeter of the slab.

(h) The applicant must construct the floors and walls of the development in accordance with the specifications listed in the tablebelow.

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

K0101 59.4 32.8

K0102 48.2 37.3

K0103 22.4 30.7

K0104 18.1 58.5

K0109 49.5 41.5

K0110 64.5 25.1

K0210 19.7 20.2

K0211 47.2 27.5

K1005 43.0 16.5

K1007 42.5 17.0

K1008 50.8 18.5

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 30/37

Page 47: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

K1010 26.4 14.8

K1011 56.0 18.3

K1105 27.0 24.7

K1106 28.3 22.7

K1107 25.9 25.6

K1202 64.5 28.8

K1401 64.5 18.8

K1402 53.9 23.7

K1403 32.8 15.1

K1404 34.6 45.5

K1405 36.2 21.8

K1406 36.3 20.2

K1407 35.0 22.4

K1408 46.7 21.1

K1409 62.6 20.4

K0105, K0107 35.2 36.3

K0106, K0108 43.0 33.5

K1102, K1302 64.5 28.2

K1205, K1305 26.8 25.1

K1206, K1306 28.6 22.8

K1207, K1307 26.2 25.3

K1109, K1209, K1309 52.5 18.3

K0310, K0410, K0510, K0610,K0710, K0810, K0910

20.8 15.0

K0311, K0411, K0511, K0611,K0711, K0811, K0911

48.6 18.5

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 31/37

Page 48: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Thermal loads

Dwelling no. Area adjusted heating load (in mJ/m²/yr) Area adjusted cooling load (in mJ/m²/yr)

K0202, K0302, K0402, K0502,K0602, K0702, K0802, K0902,K1002

55.3 21.9

K0201, K0301, K0401, K0501,K0601, K0701, K0801, K0901,K1001, K1101, K1201, K1301

54.9 23.4

K0203, K0303, K0403, K0503,K0603, K0703, K0803, K0903,K1003, K1103, K1203, K1303

19.6 15.8

K0204, K0304, K0404, K0504,K0604, K0704, K0804, K0904,K1004, K1104, K1204, K1304

24.2 47.2

K0209, K0309, K0409, K0509,K0609, K0709, K0809, K0909,K1009, K1108, K1208, K1308

53.8 28.6

K0205, K0207, K0305, K0307,K0405, K0407, K0505, K0507,K0605, K0607, K0705, K0707,K0805, K0807, K0905, K0907

43.2 16.8

All other dwellings 49.5 18.4

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 32/37

Page 49: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(b) Common areas and central systems/facilities

(i) Water Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table.

(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.

(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable.

(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table.

(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table.

(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table.

Common area Showerheads rating Toilets rating Taps rating Clothes washers rating

All commonareas

no common facility no common facility no common facility no common laundry facility

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.

(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.

(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 33/37

Page 50: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Common area ventilation system Common area lighting

Common area Ventilation system type Ventilation efficiencymeasure

Primary type of artificiallighting

Lighting efficiencymeasure

Lighting controlsystem/BMS

Lift car (No.3) - - light-emitting diode connected to lift call button Yes

Lift car (No.4) - - light-emitting diode connected to lift call button Yes

Lift car (No.5) - - light-emitting diode connected to lift call button Yes

Central energy systems Type Specification

Central hot water system (No. 2) gas-fired storage(manifolded)

Piping insulation (ringmain & supply risers):(b) Piping internal to building: R0.6 (~25 mm)

Lift (No. 3) gearless traction with V V VF motor

Number of levels (including basement): 18

Lift (No. 4) gearless traction with V V VF motor

Number of levels (including basement): 18

Lift (No. 5) gearless traction with V V VF motor

Number of levels (including basement): 4

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 34/37

Page 51: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

5. Commitments for common areas and central systems/facilities for the development (non-building specific)

(b) Common areas and central systems/facilities

(i) Water Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table.

(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.

(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable.

(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table.

(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table.

(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table.

Common area Showerheads rating Toilets rating Taps rating Clothes washers rating

All commonareas

no common facility no common facility no common facility no common laundry facility

Central systems Size Configuration Connection (to allow for...)

Fire sprinkler system (No. 1) - - -

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 35/37

Page 52: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

(ii) Energy Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.

(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table.

Common area ventilation system Common area lighting

Common area Ventilation system type Ventilation efficiencymeasure

Primary type of artificiallighting

Lighting efficiencymeasure

Lighting controlsystem/BMS

Car park area (L2) ventilation (supply +exhaust)

carbon monoxide monitor +VSD fan

light-emitting diode time clock and motionsensors

Yes

Car park area (L1) ventilation (supply +exhaust)

carbon monoxide monitor +VSD fan

light-emitting diode time clock and motionsensors

Yes

Car park area (L0) ventilation (supply +exhaust)

carbon monoxide monitor +VSD fan

light-emitting diode time clock and motionsensors

Yes

Switch room/CommsRoom/Services

ventilation supply only interlocked to light compact fluorescent motion sensors Yes

Garbage rooms ventilation exhaust only - compact fluorescent motion sensors Yes

Fire Control Centre air conditioning system thermostatically controlled compact fluorescent motion sensors Yes

Fire Stairs no mechanical ventilation - light-emitting diode motion sensors Yes

Lobbies/Corridors no mechanical ventilation - light-emitting diode motion sensors Yes

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 36/37

Page 53: BASIX Report - City of Ryde€¦ · BASIX Report Lachlan’s Line – Lot 105 North Ryde Prepared for: Prepared by: ... As a result, the energy model results only represent an interpretation

Notes

1. In these commitments, "applicant" means the person carrying out the development.

2. The applicant must identify each dwelling, building and common area listed in this certificate, on the plans accompanying any development application, and on the plans andspecifications accompanying the application for a construction certificate / complying development certificate, for the proposed development, using the same identifying letter orreference as is given to that dwelling, building or common area in this certificate.

3. This note applies if the proposed development involves the erection of a building for both residential and non-residential purposes (or the change of use of a building for bothresidential and non-residential purposes). Commitments in this certificate which are specified to apply to a "common area" of a building or the development, apply only to that part ofthe building or development to be used for residential purposes.

4. If this certificate lists a central system as a commitment for a dwelling or building, and that system will also service any other dwelling or building within the development, then thatsystem need only be installed once (even if it is separately listed as a commitment for that other dwelling or building).

5. If a star or other rating is specified in a commitment, this is a minimum rating.

6. All alternative water systems to be installed under these commitments (if any), must be installed in accordance with the requirements of all applicable regulatory authorities. NOTE:NSW Health does not recommend that stormwater, recycled water or private dam water be used to irrigate edible plants which are consumed raw, or that rainwater be used forhuman consumption in areas with potable water supply.

Legend

1. Commitments identified with a " " in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if a

development application is to be lodged for the proposed development).

2. Commitments identified with a " " in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a construction

certificate / complying development certificate for the proposed development.

3. Commitments identified with a " " in the "Certifier check" column must be certified by a certifying authority as having been fulfilled. (Note: a certifying authority must not issue an

occupation certificate (either interim or final) for a building listed in this certificate, or for any part of such a building, unless it is satisfied that each of the commitments whose fulfilmentit is required to monitor in relation to the building or part, has been fulfilled).

BASIX Planning & Environment www.basix.nsw.gov.au Version: 2.3 / CASUARINA_2_38_3 Certificate No.: 717601M Friday, 08 July 2016 page 37/37