Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of...

18
Base Isolation Technology November, 2000 Principle of Base Isolation System Example of Base-isolation Building Analytical Model of Base-isolation Buil Input Earthquake Waves Results of Earthquake Response Analyses 1

Transcript of Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of...

Page 1: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

Base Isolation Technology

November, 2000

・ Principle of Base Isolation System

・ Example of Base-isolation Building

・ Analytical Model of Base-isolation Building

・ Input Earthquake Waves

・ Results of Earthquake Response Analyses

1

Page 2: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI22

To  TOP

Principle of Base Isolation System

Base Isolation System is like a Suspension System of Motorcar

Soft spring + Oil Damper

Damper Laminated rubber bearing

2

Page 3: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI33

To  Back

Laminated rubber bearing

Soft in Horizontal directionHard in Vertical direction

Rubber Sheet

Steel Plate

Base Isolation System

3

Page 4: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI44

To  Back

Base Isolation System

Laminated rubber bearing

Rubber block

Rubber block

Laminated rubber bearing

1. Vertical direction

2. Horizontal direction

Principle of Laminated rubber bearing

Rubber block

4

Page 5: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI55

To  TOP

Steel damper

Lead damper

Base Isolation System Damper

Oil damper

Friction damper with Coned disc springs

5

Page 6: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI66

Example of Base-isolation Building

Base Isolated Research Building Base Isolation Device

Location : Tokyo

Architect : Obayashi Corporation

Structure : RC ; B1,5F

Total floor area : 1,624 m 2

Date of completion : August 1986

6

Page 7: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI77

Example of Base-isolation Building

Base Isolated Research Building (Elevation)

Base Isolation Device (Floor Plan)

7

Rubber BearingSteel Damper

Page 8: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI88

Base Isolation Building

Principle

Seismic Acceleration Response Spectrum

8

Comparison of Seismic Response

Am

pli f

icat

ion

fact

or o

f ac

c ele

r atio

n

Period(sec.)

Conventional Building

Base Isolation Building

Story Displacement Acceleration Story Displacement Acceleration

El Centro 1940NS25Kine Input

Base Isolation System

Page 9: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI99

Analytical Model of Base-isolation Building

9

Story Weight Total Horizontal Natural NaturalWeight stiffness Frequency period

Floor W ton W ton KH ton/cm Hz sec6F 543 543

415 1 mode 0.754 1.3265

5F 412 955415 2 mode 2.598 0.3849

4F 412 1,367455 3 mode 4.948 0.2021

3F 422 1,789518 4 mode 7.189 0.1391

2F 414 2,203615 5 mode 8.985 0.1113

1F 705 2,90881.36 6 mode 10.341 0.0967

Mode

EigenvalueAnalytical Model

4.2m

4.2m

4.25m

4.3m

4.3m

6

0.5mRubber Bearing Steel Damper

5

4

3

2

1

Page 10: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1010

Analytical Model of Base-isolation Building

10

Hysteresis Characteristics

0

100

200

300

400

500

600

0.0 1.0 2.0 3.0 4.0 5.0

Displasement(cm)

1F(Base-isolation)6F

5F

4F

3F

2F

Page 11: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI

Input Earthquake Waves

11

KOBENS(818gal)

DZCEW(369gal)

YPTNS(321gal)

-1000

-500

0

500

1000

0 5 10 15 20 25

Inpu

t Acc

.(ga

l)

Time (sec.)

-400-300-200-100

0100200300400

0 5 10 15 20 25

Inpu

t Acc

.(ga

l)

Time (sec.)

-400-300-200-100

0100200300400

0 20 40 60 80 100

Inpu

t Acc

.(ga

l)

Time (sec.)

Page 12: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1212

Effectiveness of Base Isolation System

12

DZCEW369gal YPTNS321gal

0

1

2

3

4

5

6

0 200 400 600 800 1000

Acceleration Distribution (DZCEW)

ConventionalBase-isolation

story

gal0

1

2

3

4

5

6

0 200 400 600 800 1000

Acceleration Distribution (YPTNS)

ConventionalBase-isolation

story

gal

Page 13: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1313

Results of Earthquake Response Analyses

13

Response Acceleration Story Displacement

0

1

2

3

4

5

6

0 5 10 15 20 25

KOBENS 818galDZCEW 369galYPTNS 321gal

story

cm 0

1

2

3

4

5

6

0 5 10 15 20 25

KOBENS 818galDZCEW 369galYPTNS 321gal

story

cm

Page 14: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI14

-1000

-500

0

500

1000

0 5 10 15 20 25Time (sec.)

KOBENS(818gal)

DZCEW(369gal)

YPTNS(321gal)

Results of Earthquake Response Analyses

-1000

-500

0

500

1000

0 5 10 15 20 25

KOBENS Base-isolation

Acc.(gal)

(sec.)

-400-300-200-100

0100200300400

0 5 10 15 20 25

DZCEW Base-isolation

Acc.(gal)

(sec.)

-400-300-200-100

0100200300400

0 10 20 30 40 50 60

YPTNS Base-isolation

Acc.(gal)

(sec.)

Page 15: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1515

Results of Earthquake Response Analyses

15

Hysteresis Characteristics

0

100

200

300

400

500

600

0.0 1.0 2.0 3.0 4.0 5.0

Displasement(cm)

1F(Base-isolation)6F

5F

4F

3F

2F

Page 16: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1616

Results of Earthquake Response Analyses

16

-600

-400

-200

0

200

400

600

-30 -20 -10 0 10 20 30

1F2F3F4F5F6F

Shere Force (ton)

Displasement (cm)

-600

-400

-200

0

200

400

600

-30 -20 -10 0 10 20 30

1F2F3F4F5F6F

Shere Force (ton)

Displasement (cm)

DZCEW YPTNS

Hysteresis Characteristics

Page 17: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1717

Effects of Base Isolation System

17

Building with Seismic Isolation

Conventional Building

・ Improvement for Safety of Building・ Keep for Function of Building・ Preservation for Property

Page 18: Base Isolation Technology November, 2000 ・ Principle of Base Isolation System ・ Example of Base-isolation Building ・ Analytical Model of Base-isolation.

OBAYASHI1818

Application of Base-isolated Structure

1) Government and Municipal Office, Fire Station, Police Station, Broadcasting Station2) Hospital, Social welfare facilities3) Laboratory4) Computer Center5) Museum, Gallery, Library6) Apartment House7) Cultural Asset, Historic Structure

18