Babcox Boiler
Transcript of Babcox Boiler
-
8/12/2019 Babcox Boiler
1/14
-
8/12/2019 Babcox Boiler
2/14
Since 1867, The Babcock &
Wilcox Company (B&W) has
been designing, manufacturing,
installing and commissioning
the worlds most reliable and
efficient steam-generating
systems and environmental
equipment. B&W also services,
repairs, modifies, upgrades
and replaces existing systems
and associated equipment,
regardless of the original
manufacturer. With boiler
installations operating in more
than 85 countries, B&W has
the experience and flexibility
to meet the ever-changing
needs of both the industrial
and utility markets. B&W is
recognized globally for its
unmatched responsiveness
to customers needs.
2
-
8/12/2019 Babcox Boiler
3/14
BURNERSSUPERHEATER
SCREEN TUBESBOILER BANK
STEAM DRUM
FURNACE
LOWER DRUM
B&W PFI Boiler
B&W PFT Boiler
3
GAS OUTLET
SCREEN TUBES
LOWER DRUM
STEAM DRUM
SUPER-HEATER
INTEGRAL AIR PLENUM
BURNERS
STEAM COILAIR HEATER
AIRHEATER
GASOUTLET
FORCED-DRAFTFAN
FURNACE
-
8/12/2019 Babcox Boiler
4/14
Proven Design for Dependable Steam Production
Reliable performancein a wide variety ofindustries
B&Ws PFI (Power forIndustry) and PFT (Powerfor Turbine) integral furnaceboilers continue our traditionof excellence with over275 units totaling more than78,000,000 lb/hr of steamcapacity worldwide. Ourestablished reputation forreliability and provenperformance is continuallyenhanced by incorporatingcustomer feedback in
conjunction with the latesttechnological advancementsin our design. Many 1950vintage PFI/PFT boilers are
still in service today. Theconservative furnace sizeand burner spacing of thePFI/PFT design has provenitself to be a reliable work-horse across a wide rangeof heating, process andpower markets such as: Petroleum and chemical
refineries Pulp and paper mills Steel mills Manufacturing and
processing facilities
PFI PFT
Steam Flow 100,000 to 700,000 lb/h 350,000 to 800,000 lb/h
(45 to 317 tm) (159 to 363 tm)
Steam Pressure Up to 1150 psig (79.3 bar) Up to 1800 psig (124.1 bar)
Steam Temperature Up to 960 F (516 C) Up to 1000 F (538 C)
Approx. Superheater Steam40 to 100% (Natural Gas) / 60 to 100% (Oil)
Temperature Control Range
Standard Sizes Available 11 37
Furnace Tube Size / Spacing 2.5 in. OD (6.35 cm) 3.0 in. OD (7.62 cm)
on 3.0 in. (7.62 cm) centers on 3.75 in. (9.53 cm) centers
Superheater Tube Side Spacing 6 in. (15.24 cm) 4.5 in. (11.43 cm)
Generating Bank Gas Flow Horizontal Vertical
Fuels Natural Gas, Refinery Gas, Oil, CO, BFG, COG,
Various Combustible Byproduct Gases and Liquids
Waterside Design Natural Circulation
Type of Support Bottom Support
Setting Design Pressurized Furnace
Type of Superheater Fully Drainable
Installation Indoor Outdoor
Utility power generationplants
Municipalities Heating for corporate and
institutional buildings
System componentscomplement operation
Specifically designed tocomplement each other inoperation, all major compo-nents in the PFI/PFT boilersystem can be supplied byB&W depending on yourneeds: Boiler
Instruments and controls
Burners, staging ports andburner management system
Valves Fans
Motors Sootblowers Flues, ducts, dampers
and expansion joints Platforms and steel Additional options
(feedwater pumps, fuelpump and heating set,deaerators, chemicalfeed systems, economizers,air heaters, environmentalequipment, steel stacks)
Pre-engineered B&W PFI/PFT boilers are available in a wide range of sizes and operating conditions:
4
-
8/12/2019 Babcox Boiler
5/14
Designed and Built From Experience
Features and Benefits: Furnace
Welded membrane wall construction provides the gas-tight setting absolutely necessary for allPFI/PFT boilers. This construction minimizes outages caused by gas leaks. B&Ws membranewall panels use large diameter tubes and small membrane spacing. This provides a larger volumeof water in our furnace walls which results in the best combination of heat transfer efficiency,faster load response and maintenance accessibility.
3-3/4 in.3 in. O.D.Tubes
3/4 in.
3 in.2-1/2 in. O.D.Tubes
1/2 in.
With the advent of the PFIboiler in 1958, B&Wsengineers were the first torecognize that if boilers
could be designed withoutconsideration for solid fuels,they could incorporate manycost-saving features withoutsacrificing quality anddependability. Accordingly,B&W incorporated manyinnovations which had neverbefore been integrated inindustrial boilers. Theseincluded membrane wallsetting, maximum shopassembly of components,
fully drainable superheaters,minimal use of refractory,complete bottom supportand integral air plenums.
In the late 1960s, the B&WPFT was developed in
response to the need for arugged and versatile boilerwhich would provide high-pressure, high-temperature
steam, yet would fire practi-cally any liquid or gaseousfuel. By pre-engineering allcomponents which combinefor the various sizes andoperating conditionsrequired, B&W designengineers provided substan-tial savings in installedcost, as well as a significantdecrease in the time betweenthe placing of an order fora PFI/PFT and its initial
operation.
B&Ws PFI/PFT boilersoperate on positive furnacepressure from a singleforced draft fan, eliminatingthe need for an induced
B&W maximizes shop assembly of components
to save time and money.
Furnace membrane walls; front, side, roof and floor
PFI PFT
Seal at furnace corner
5
draft fan, motor andauxiliaries, along with theassociated operating andmaintenance costs.
Without question, thePFI/PFT boiler design drivesmaintenance to a minimum.
-
8/12/2019 Babcox Boiler
6/14
GasFlow
Baffle
Baffle
PFT - SIDE VIEW
Furnace waterwall cooling includes not only the furnace front wall, side walls, roof and floor, but the
high heat duty screen tubes in front of the superheater as well. This unique boiler feature locates totalwater cooling where it can contribute most to keeping maintenance costs down. Each screen tube is asingle flow path between drums to assure proper circulation and cooling.
When B&W designed the PFI/PFT, every effort was made to minimize furnace refractory, a majormaintenance area in boilers. Burners are located together on the furnace front (firing) wall, incorporatingfully water-cooled throats. As a result, there is no troublesome burner tile to point up or replace. The onlybaffle used in a PFI is located at the cool boiler outlet zone. The PFT has no hot refractory baffles, onlywater-cooled refractory, an alloy plate supported in the hot zone and an alloy plate in the cool zone.
For applications requiring extended steaming capacities, low draft loss or high gas flow conditions, thePFI can be arranged as a twin furnace by joining two opposite-hand PFIs side-by-side.
Typical gas flow through available generating bank arrangements
Baffle
Baffle Wall
Gas
FlowPFI - PLAN VIEW
Baffle
Baffle Wall
Gas
FlowPFI - TWIN PLAN VIEW
Gas
Flow
Baffle
A complete boiler bank assembly
is moved into place for installation.
B&W takes full advantage of maximum shop assemblyof components. The furnace is shipped to the field in10 to 15 pieces with all headers shop welded. Even the frontwall is shop assembled, complete with burners and windbox,
saving time and money while assuring high quality control.
Features and Benefits: Furnace (Continued)
6
PFI PLAN VIEW GasFlow
GasFlow
GasFlow
PFI TWIN PLAN VIEW
BaffleBaffle
Baffle
Baffle Wall
Baffle Wall
Baffle
Baffle
PFT CROSSFLOW SIDE VIEW
GasFlow
PFT - SIDE VIEW
Baffle
GasFlow
Baffle
PFT LONGFLOW SIDE VIEW
GasFlow
-
8/12/2019 Babcox Boiler
7/14
Bottom support provides the most economi-cal arrangement and requires less headroom inthe plant. Separate supports are located forthe drums, superheater headers and furnace.Clearances, seals and supports are designedfor known expansions in all directions from the
fixed point.
The forces from normal operating positive furnacegas side pressures are contained by a systemof buckstays comprised of tie bars and wideflange structural members. This buckstay systemaccommodates the effects of thermal expansion,temperature and pressure stresses, as well aswind and earthquake loading appropriateto the plant location. Because our buckstaysare not welded to the furnace walls, weld tearsare eliminated.
Our furnace seal design provides a continuousgas-tight seal between the tube membrane anddrums. Where inner cased construction is used, a10-gauge plate is welded to the tie bars instead ofdirectly to the pressure parts. To maintain casingabove the dew point temperature, the plateis formed around the tie bar to ensure closeplate-to-tube contact.
Recognizing the need to avoid departure fromnucleate boiling (DNB), our engineers havedesigned the furnace to achieve conservativeheat flux rates. For the same heat input, the PFI/PFT furnace has a heat flux rate less than half thatof a package-type boiler, making it especiallytolerant of boiler water containing high silicaand organics.
The PFTs design allows furnace height to varyindependently of the boiler height. Therefore,a taller boiler bank is not required for a tallerfurnace.
Tie Bar
StandoffBar
Pin Tie Bar
BuckstaySupport Lug
End ConnectionAssembly Buckstay
Sidewall
Roof
Tubes
Seal
Weld
3/8 in. Dia.
RND Bar
B&Ws PFI and PFT boilers are bottom supported
to provide the most economical arrangement.
Buckstay arrangement
Roof seals provide a continuous gas-tight seal.
7
SuperheaterHeader Supports
Clips
FurnaceSupports
Drum Saddle
Drum Foundation
Tie BarPin
StandoffBar
Tie Bar
End ConnectionAssembly
BuckstaySupport Lug
Buckstay
Sidewall
SealWeld
Roof
Tubes
3/8 in.Dia.
-
8/12/2019 Babcox Boiler
8/14
Features and Benefits: Drums and Circulation
B&W PFI/PFT boilers are designed with extra-large steamdrums fit with the best available steam separating internalsfor high steam purity and positive circulation. Because theintent is to provide the driest steam possible for process orturbine, as well as the most solid recirculating water head,all PFIs and PFTs are equipped with B&W Cyclone SteamSeparators and two stages of downstream scrubbers.
Water
Steam
Steam andWater fromRisers
Baffle
B&W Cyclone Steam Separators provide the highest
steam purity and ensure positive circulation.
8
Features and Benefits: Superheater
The superheater incorporates B&Ws proven multi-pass design for high steam velocities, assuringequalized cooling steam distribution in all circuits.This minimizes the need for high alloy steels, even in
areas of highest temperature. Because the super-heater is positioned in a partial radiant heat zone, thesteam temperature characteristic of the PFI/PFTis nearly flat from about half load and higher.This affords close control of process heatingrequirements or turbine operation over a wideload range while minimizing attemperationrequirements.
Fully drainable superheaters, specially designedby B&W for PFI/PFT boilers, do not trap hydrowateror steam condensate. Compared to pendant
superheaters that must be boiled clear, B&Wsdrainable design saves valuable time during startupwhile minimizing the chances of over-heat duringthe pressure-raising stage.
The PFI/PFT superheater circuits are completelywelded from header to header. All bends areprecisely die formed; no cast or forged bends areused. Tube materials and thicknesses may be
customized for special applications.
The PFI/PFT superheater also benefits from itspositive bottom support. This allows only minimumdifferential expansion relative to furnace floor tubes.Lateral tube supports maintain gas lane spacingand limit vibration. Headers are located in their ownvestibule, well out of the flue gas stream, and thesuperheater incorporates a convenient outlet con-nection at the operating-floor elevation.
The PFT superheater elements are spaced closer
together (4-1/2 in. center-to-center) compared withthe PFI (6 in. center-to-center). This means that thePFT can accommodate more rows of surface forthe same boiler width, making it a favorite for highsteam temperature requirements.
Dry Steam
Steam andWater from
Risers
Baffle
Steam-Free Water
-
8/12/2019 Babcox Boiler
9/14
Even when load changes and transientconditions are wide and frequent, B&WsPFI/PFT steam drum internals and watercircuit design have been developed toassure positive circulation across the
entire load range. The circulation design
of the PFI/PFT has been developed so thatall high heat absorbing tubes are carefullyarranged as vertical upflowing circuits,and downcomer circuits are specificallylocated in the low gas temperature regionof the boiler.
Incorporating the use of B&Ws CycloneSeparator steam drum internals comple-ments the circulation design by providingexcellent steam purity and steam-free
recirculated waterthat assure adequatecirculation flow to satisfy the design
conditions at all loads. The design of theboilers circulation system with the CycloneSeparator steam drum internals minimizesthe drum water level swings that can occurwith high-capacity boilers. With appropriatecontrols, the ample steam drum volumewith B&W internals can be designed tohandle a wide variation in load change.
When superheaters or special processes
are required, steam with less than 1 ppmsolids can be obtained. Turbine blades arekept cleaner and costly superheater tubefailures caused by solids carryover aresignificantly reduced. The drum internalsdesign also allows free end flow to minimizeturbulence and end-to-end level fluctuation.
Water tubes entering the drums are rolledinto specially grooved seats to providemore holding power and seal integrity asdemonstrated by over ten million rolled
joints worldwide. Tube joints operatingabove 1500 psig (103.4 bar) are sealwelded for additional seal integrity.
Tube Expandedinto Grooves
GeneratingBank Tube
Drum
Seal Weld(Over 1500 psi
Design Pressure)
Rolled tube joints and grooved tube seats provide
excellent holding power and seal integrity.
Saturated Connections
Steam Sampling
DrypanSecondaryScrubber
PrimaryScrubber
Normal Water Level
CycloneSeparators
1in.
ChemicalFeed
FeedwaterDistribution
PipeContinuousBlowdown
Downcomers Riser Tubes
Specially designed steam drum internals
enable rapid load changes.
9
-
8/12/2019 Babcox Boiler
10/14
The integral air plenum concept designed into B&Ws PFI assures that installation at the plantis vastly simplified. The straight-through arrangement of the PFI/PFT boiler with a regenerativeair heater is the most common because it is the most functional. However, because the plenum(integral duct-flue surrounding the rear, top and front of the PFI) can be internally baffled toaccommodate almost any duct inlet or flue outlet, an unlimited number of both air heater andeconomizer arrangements are possible. The PFT air duct is routed under the furnace floor. Bothplenum arrangements make operation easier and minimize space requirements.
A lower drum heating coil can be supplied to maintain the boiler in a hot standby condition,substantially reducing re-start time from a matter of hours to a matter of minutes. Thermal sleeveconnections, which eliminate stress from differential expansion, are standard.
A lower drum heating coil will
reduce re-start time.
Lower Drum
ThermalSleeve
Heating Coil
Coil SupportBrackets
SteamIn
CondensateOut
Features and Benefits: Burners and Environmental Equipment
Designed primarily for natural gas and oil firing,the PFI/PFT is also used for incinerating a widerange of liquid and gaseous waste fuels, and asa heat recovery boiler for gas turbines. Withmultiple burners and suitable controls, self-sustaining fuels can be fired individually or incombination.
The burner wall is large enough to accommodatea wide range of burner types and configurationsincluding those of B&Ws design or others.
A portion of the combustion air can be introducedthrough sidewall ports located downstream ofthe burners to promote staged burning for lowerNOx emissions. Recirculated flue gas may beintroduced into the combustion air stream for
additional NOx control. The completely water-cooled firing wall absorbs additional heat fromthe gas, thereby limiting thermal NOx formation.
For the same input, the PFI/PFT furnace hasabout six times the volume of a package-typeboiler which better accommodates long flamelengths typical of todays low NOx oil and gasburner technology.
B&W is responsive to ever-tightening requirementson airborne emission limits. Given the variety offuels that can be burned in the PFI/PFT, B&W willsupport your air emission requirements with add-on technology for control of acid gas, particulateand other specified compounds.
10
Special Features Set the PFI/PFT Apart From Others
Lower Drum
Heating Coil
SteamIn
CondensateOut
ThermalSleeve
Coil SupportBrackets
-
8/12/2019 Babcox Boiler
11/14
Master hand hole (MHH) fitting
Babcock & Wilcox DesignCompetitors Design
Seat Seat
Master Hand Hole (MHH) Fitting
3/8 in.Maximum
Header
Flexible BlockInsulation
Membrane Wall
InsulationSupport Tine
Self-Attaching Speed Nutwith Tine Bent Over
ProtectiveMetal Lagging
Membrane wall with block insulation and lagging
enables indoor or outdoor installation.
11
Special inspection doors for pressurizedoperation allow observation of both com-bustion conditions and cleanliness ofheat-absorbing surfaces. Safety is providedby a special interlock that assures thatcompressed air is properly aspirating at theaperture before the door is opened.
Economizers and air heaters are availablefor increased efficiency. Pre-engineeredarrangements of extended surface or bare-tube economizers, as well as regenerative ortubular air heaters are offered to meet varyingfuel, space and economic considerations.
Sootblowers are properly located for effectivecleaning of the superheater and generatingbank heat transfer surfaces. Sootblowerbearings, wallboxes and tube openings are
standard on all PFI/PFT boilers, regardless offuels fired.
PFIs firing oil or other ash-containing liquidshave boiler banks arranged for effective laneblowing via rotating-type sootblowers. Moltenoil ash normally will run off superheater tubesmaking sootblowers in this area unnecessary.Where a particular ash makes liquid-to-solidtransition at the entrance to boiler banks,retractable sootblowers can be located at thisarea. The PFT has wide cavities within the boilerbank to accommodate the number of soot-blowers necessary to handle especially toughcleaning requirements.
Wash-water troughs and drains are standardon every new PFI/PFT boiler to facilitate off-line water-washing.
Master hand hole (MHH) fittings are strategi-cally located in water and steam headerswhere access is required. The MHH fitting
weld is designed to avoid cracking associatedwith stress build-up in the seat.
Indoor or outdoor operation are both madepossible by the all-metal lagging constructionwhich presents a good appearance, is quitedurable and requires minimal maintenance.
MHH fitting is un-seated whenweld cools and contracts,eliminating stress build-up
in the weld.
MHH fitting is seated tightlyto header when weld cools andcontracts, leaving weld stressed
and vulnerable to cracking.
Competitors Design Babcock & Wilcox Design
Master Hand Hole (MHH) Fitting
Seat Seat
Header3/8 In.
Maximum
Flexible BlockInsulation
InsulationSupport Tine
ProtectiveMetal Lagging
Membrane Wall
Self-Attaching Speed Nutwith Tine Bent Over
-
8/12/2019 Babcox Boiler
12/14
Total Scope Supplyand Services
B&Ws extensive, worldwide
experience allows us theflexibility to easily meetdiverse project requirements anything from a knock-downboiler to an entire steamisland. We can package yourboiler system with properlysized, quality auxiliaries tomatch your needs and ourstandards of excellence.
Stringent quality control
standards
At B&W, quality assuranceis integral to our design,engineering and manufac-turing processes. To ensureall codes and specificationsare met, B&W uses stringentquality control proceduresand sophisticated testingapparatus. Rigid standards
B&Ws manufacturing facilities maintain
the highest quality standards.
12
-
8/12/2019 Babcox Boiler
13/14
have been established for ourmaterial suppliers as well.
B&Ws commitment toquality is evidenced by our: Advanced technology
B&W builds quality intoits products during every
process and stage. Strength in size and
capacity facilities,manpower and globalpresence provide youwith a complete rangeof fabricating processes.
Outstanding responsive-ness B&W is equippedand structured to meetyour delivery needs andrequirements.
Manufacturing andsafety excellence
B&W PFI/PFT boilersare designed, engineeredand manufactured at ourWest Point, Mississippi,USA facility. This plant isISO-9001 registered, ASMEcode approved and is incompliance with AWS coderequirements. B&Ws West
Point plant also maintains anoutstanding safety record andhas been awarded the OSHAStar Status in the VoluntaryProtection Program.Manufacturing and safetyexcellence are a continuousgoal for B&W.
Worldwide responsiveservice and manufac-turing support
B&Ws network of domesticand international sales repre-sentatives and field serviceengineers assures you of aprompt response whetherservicing and upgrading yourexisting system or specifyingnew equipment. We canprovide services rangingfrom routine inspection andcontrols tuning to capacity
increase engineering studies,low emissions conversions, ornew digital control systems.
To meet the needs of theglobal market, we alsodesign, engineer and manu-facture PFI/PFT boilers in
accordance with all B&Wstandards through variousinternational operations andlicensees.
Support services
B&W believes that customersatisfaction and trust is builtby maintaining close contactwith the customer after thesale. In addition to equipmentsupply, B&W offers compre-hensive support servicesincluding: Field service engineering Inspection and maintenance
services Engineered upgrades or
custom modifications Long-term service
alliance programs Training programs Operating instructions Spare parts manuals
Start-up and commissioningservices Replacement part ordering
by phone or Internet24 hours a day
Reliable single-sourcesupplier
B&Ws proven expertise inboilers, burners and controlsmakes us a reliable andresponsive single source for
PFI/PFT boilers and auxiliaryequipment. From engineeringand manufacturing to fieldconstruction, start-up andoperation, B&W knows howto make it all work togetherfor maximum operatingefficiency and dependability.
A network of B&W field service engineers is available for
customer support long after the sale is completed.
13
-
8/12/2019 Babcox Boiler
14/14