Operating Instructions
KNH34 High Voltage Generator
BA-e-3010-0408
F00
019
electrostatic
innovations
2 BA-e-3010-0408_KNH34
List of Contents1 Outline of Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.1 Identification of risks and hazards . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2 Contact protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.3 Technical advance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.5 Work and operational safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Installation and Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103.1 Assembly of the high voltage generator . . . . . . . . . . . . . . . . . . . . . 103.2 Installation of the high voltage cables. . . . . . . . . . . . . . . . . . . . . . . 113.3 Charging bars suitable for connection . . . . . . . . . . . . . . . . . . . . . . 123.4 Connecting the high voltage cable to the generator and
to the distribution box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133.5 Cutting the high voltage cable to length . . . . . . . . . . . . . . . . . . . . . 143.6 Disconnecting the high voltage cable . . . . . . . . . . . . . . . . . . . . . . . 163.7 Connecting the supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.8 Digital interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.9 Analog interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204.1 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204.2 User concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214.3 Overview of functions with options and default settings . . . . . . . . . 224.4 Selecting the output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244.5 Selecting the output voltage during operation . . . . . . . . . . . . . . . . 254.6 Selecting the output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264.7 Selecting the output current during operation. . . . . . . . . . . . . . . . . 274.8 Selecting the operating parameters . . . . . . . . . . . . . . . . . . . . . . . . 284.9 Loading the default settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
9 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
10 Spare parts list and accessories. . . . . . . . . . . . . . . . . . . . . . . . . 46
BA-e-3010-0408_KNH34 3
electrostatic
innovations
electrostatic
innovations
4 BA-e-3010-0408_KNH34
Dear customer,The KNH34 High Voltage Generator is a multi-purpose voltage supply unit for any high voltage application and for Eltex DC-operated charging bars.
The following bar models are available for connection: R130A/R131A,R120/R121A (note voltage limitation acc. to Operating Instructions
R120/R121A),R23ATR.
Programmable output and monitoring parameters, an outstanding feature of the KNH34 microprocessor-controlled high voltage generator, allow it to be adapted to any kind of operating condition. User operation is menu-assisted; texts and messages appear in plain text on a two-line display.
Also, the new terminal concept and the monitoring of important functions (high voltage cascade, calibration short-circuit current, voltage and current limitation) of the KNH34 high voltage generator provides the ultimate in safety standards.
With a minimum of wiring, its new digital field bus concept (CAN Bus) allows as many as 20 generators and remote controls to be networked. Due to the option of forming functional groups, even in complex plants, access via the remote control remains easy and clearly structured.
The RS-232 interface integrated in the remote control also allows the unit to be operated via the control room.
Please read these instructions carefully before starting the unit. This will help you prevent personal injuries and damage to property.
Simply give us a call if you have any suggestions, proposals or ideas for improvements. We greatly appreciate the feedback from the users of our appliances.
BA-e-3010-0408_KNH34 5
electrostatic
innovations
1. Outline of Appliance
1 High voltage output 12 High voltage output 23 Socket, analog interface4 Socket, CAN bus (female)5 Ground terminal6 Socket, CAN bus (male)7 Socket, system input8 Fuses (see name plate)9 Master switch ON/OFF10 Operator interface two-line display, keypad
Fig. 1:KNH34 High Voltage Generator
Z00
093y
Hochspannungsgenerator
High Voltage Generator
AbbruchEscape SollwertSetpoint SpannungVoltage
KNH 34
1 2 3 4 5 6 7 8 9 10
electrostatic
innovations
6 BA-e-3010-0408_KNH34
2. SafetyThe units have been designed, built and tested using state-of-the-art engi-neering, and have left the factory in a technically and operationally safe condition. If used improperly, the units may nevertheless be hazardous to personnel and may cause injury or damage. Read the operating instruc-tions carefully and observe the safety instructions.
2.1 Identification of risks and hazards
Possible risks and hazards resulting from the use of the units are referred to in these operating instructions by the following symbols:
Warning!This symbol appearing in the operating instructions refers to operations which, if carried out improperly, may result in serious personal injuries.
Caution!This symbol appearing in the operating instructions refers to operations which, if carried out improperly, may result in damage to property.
Ex Warning!This symbol denotes the special conditions which must be observed when operating the system in explosion hazard areas as specified in the EX approvals.
2.2 Contact protection
The site of installation and/or use of the units is outside the control of Eltex, contact protection against inadvertent contact of the bars and of live components by personnel as specified by the employer’s liability insur-ance association may have to be provided (e.g. BGV A2 in Germany). Contact protection devices made of conductive material must be grounded.
2.3 Technical advance
The manufacturer reserves the right to make changes to the technical specifications without prior notice in order to adapt the units to state-of-the-art engineering. Eltex will provide the latest information on any changes or modifications in the operating instructions on request.
2.4 Proper use
The KNH34 high voltage generator has been approved as operating volt-age generator for the appropriate Eltex charging bars. It must be operated only with the appropriate Eltex electrode bars (see chapter Installation and Assembly for electrode bar models).
Ex!
BA-e-3010-0408_KNH34 7
electrostatic
innovations
If the unit is used in any other high voltage application, the manufacturer´s warranty covers the safe use in terms of technical safety.
The manufacturers will not assume any liability and warranty if the units are used improperly or used outside the intended purpose.
Modifications or changes made to the devices are not permitted.
Use only original Eltex spare parts and equipment.
2.5 Work and operational safety
Warning!Carefully observe the following notes!Always observe the rules and regulations applying in your country with reference to opening and repairing electrical appliances.• The unit and the charging bars must be installed, repaired, serviced
and tested by qualified personnel only.• Before carrying out repairs, cleaning or maintenance work and before
resetting the unit after malfunctions, switch off the high voltage genera-tor and disconnect the mains power supply.
• If the housing cover is removed and the supply voltage is switched on at the same time, contact protection is no longer effective. Always dis-connect the power before opening the units.
• Check the high voltage generator and the connected charging bars at regular intervals for any damage to the electrical wiring and the high voltage cables. Any damaged components must be repaired or replaced before continuing to operate the unit, or the appropriate elec-trode bar and the high voltage cables must be disabled.Make sure that the electrode bars are clean at all times.
• Connect or remove the electrode bars only after the supply voltage to the high voltage generator has been disconnected.
• The IP 54 protection class applies only if the lid of the enclosure is closed and the cable entries are covered.
• The operation of the electrodes can generate ozone. The ozone con-centration levels developing near the electrodes depend on many dif-ferent factors such as site of installation, electrode stream and voltage, air circulation, etc., and can therefore not be specified in general terms.If the maximum allowable concentration (MAC) of ozone must be observed at the site of installation of the electrode, the concentration must be measured on site.
• Static on personnelStatic charges on personnel are unlikely if the electrode bars are installed properly. Personnel must wear conductive footwear.Please note all national regulations regarding electrostatic charge (e.g. BGR132 in Germany).
electrostatic
innovations
8 BA-e-3010-0408_KNH34
• Before putting the high voltage generator into operation make sure that the appliance is permantly grounded via the ground terminal. The ground cable should have a minimum cross section of 1,5 mm2.
BA-e-3010-0408_KNH34 9
electrostatic
innovations
3. Installation and Assembly
3.1 Assembly of the high voltage generator
The unit is designed either for wall assembly or table mounting. Attach the unit using the assembly/mounting brackets supplied with the unit (see fig-ure). The bulging of the holes in the support plate must point in the direc-tion of the generator. When mounting the unit make sure that the operating elements and the connector terminals remain accessible and that control of the unit is not impaired.
The site of installation must be dry and free of dust, if possible. Air circula-tion above the cooling ribs must not be obstructed.
Fig. 2:Installation of the high voltage gen-erator with sup-porting plate
Z00
373y
AbbruchEscape SollwertSetpoint HochspannungHigh VoltageOn/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
386
M8
M8
M6
M6
2,5
170
410
128
330
>100
212
electrostatic
innovations
10 BA-e-3010-0408_KNH34
3.2 Installation of the high voltage cables• A minimum bending radius of 10 times the external diameter must be
maintained when routing the high voltage cable.• Do not route the cable over sharp edges (bending radius <5 mm). • Keep a minimum spacing of 50 mm between low voltage and high volt-
age cables; if this cannot be done, shield the low voltage cable. • If the high voltage cables are led through bores in conductive, grounded
materials, the minimum bore diameter D is calculated as follows from the wall thickness of the material: D = 60 mm2/wall thickness.Allow the biggest possible radius for the edges of the bore hole. Use an insulating grommet to centre the cable.
• If ungrounded and conductive objects are placed near (≤2m) the high voltage cable, influenced charges and sparking must be expected.Proper ground connection is therefore important.
• In applications using movable electrodes (e.g. film draw strips), attach the high voltage cables such that there is no cable movement near the connection point to the generator/power supply.
BA-e-3010-0408_KNH34 11
electrostatic
innovations
3.3 Charging bars suitable for connection
The following charging bars are suitable for connecting to the KNH34 high voltage generator:• R23ATR point charging bar• Charging bars R130A/R131A,• Charging bars R120/R121A (note voltage limitation acc. to Operating
Instructions R120/R121A).
The KNHV3 distributor box, available as an optional extra, allows the user to increase the number of electrode bars connected (see figure). When using this option make sure that the sum of the electrode bar currents does not exceed 5 mA.
1 Generator2 Distributor box3 High voltage cable4 Charging bars
Example:Current per meter of active bar length: 1 mASum of active bar lengths: 3 m=> maximum total current: 3 mA.
Fig. 3:Installing the generator, the distributor box and the charging bars
Z00
169y
AbbruchEscape SollwertSetpoint HochspannungHigh VoltageOn/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
3
1
2
4
electrostatic
innovations
12 BA-e-3010-0408_KNH34
3.4 Connecting the high voltage cable to the generator and to the distribution box
Warning!Electric shock hazard!Work may be carried out only if:• the supply voltage to the generator has been disconnected,• the machine is at a standstill because the electrodes pick up charges if
the material web is running.
Method:Connect the electrode bars via the prefabricated high voltage cable. Push the high voltage cables up to the stop into the socket connection. Finally, secure the adapter inside the socket with the clip provided (see figure).Cables without adapters have a color-coded marking on the flexible tubing. This marking must lie flush with the outside edge of the coupling.
Note: The clip must be fully inserted.
correct incorrect
Caution!The high voltage cable must be pushed up to the stop (90 mm for KNH34 and KNH64) into the cable inlet! The connecting area of the high voltage cable must be kept clean!
Fig. 4:Connecting the high voltage cable
Z00
178y
Fig. 5:Inserting the clip
Z00
018y
BA-e-3010-0408_KNH34 13
electrostatic
innovations
3.5 Cutting the high voltage cable to length
Warning!Electric shock hazard!Work may be carried out only if:• the supply voltage to the generator has been disconnected,• the machine is at a standstill because the electrodes pick up charges if
the material web is running.
The detachable plug connection to the high voltage generator and to the distributor box can be cut to size as required. This allows the cable to be shortened.
Method:• Shorten the high voltage cable (2) and strip as shown in the figure.
• Push the split-pin plug (4) up to the stop onto the stripped piece of wire (3). Solder the wire section protruding from the plug (9) with the split-pin plug (4) and finally cut to length.
• Before following operations push back the flexible tube (1).
Fig. 6:Stripping the high voltage cable
Z00
179y
23
3
2
Fig. 7:Fabricating the high voltage cable
Z00
180y
1 2 3 4 5 6 7 8
9
electrostatic
innovations
14 BA-e-3010-0408_KNH34
• Push the washer (5) and the tubular rivet (6) over the high voltage cable (2). Crimp tubular rivet (6) by using a hexagonal crimper (5.41 mm) (space between collar of tubular rivet and tip of split-pin plug = A).
A Connection at the KNH34 generator and at the KNHV3 distributor: 94 mm (+1/-0,5)Connection at the KNH64 generator and at the KNHV6 distributor: 124 mm (+1/-0,5)Connection at the charging bar R131A: 52,5 mm (+1/-0,5)
B Connection at the KNH34 generator and KNHV3 distributor: 56 mmConnection at the KNH64 generator and KNHV6 distributor: 86 mmConnection at the charging bar R131A: 14,5 mm
• Push flexible tube (1) into the terminal adapter (8) and secure with clip (7).
A conversion kit comprising terminal adapter, tubular rivet, split-pin plug and washer is available as accessory from Eltex.
For the cable grip device to function properly, the cable diameter must be within the range 4.8...5.3 mm. This corresponds to the 50/60 kV high volt-age cable.
Fig. 8:Fabricating the high voltage cable
Z00
199y
A B 13,5
1 2 6 5 8 4
BA-e-3010-0408_KNH34 15
electrostatic
innovations
3.6 Disconnecting the high voltage cable
Warning!Electric shock hazard!Work may be carried out only if:• the supply voltage to the generator has been disconnected,• the machine is at a standstill because the electrodes pick up charges if
the material web is running.
Take off the clip at the generator and/or the R131 bar, using a 3 mm screw driver. Then pull out the cable.
A conversion kit comprising terminal adapter, tubular rivet, split-pin plug and washer is available as accessory from Eltex.
3.7 Connecting the supply voltage
Supply voltage connection to the high voltage generator is made directly via the mains plug using a terminal connector or an earthing-pin plug linked to the mains power supply. We recommend enabling the supply voltage to the high voltage generator via a machine contact which disables the high voltage generator if the machine is stopped. This configuration will ensure that high voltage is not applied at the electrode bars with the machine stopped.
Warning!Disconnect and/or connect the mains cable on the socket only when off-load.
When using external protection fusing for generators, the following circuit-breaker must be used:6 A; tripping characteristic D in compliance with DIN VDE 0641 - 11/8.92;EN 60898/1991; IEC 898/1987 modified 11/91.
electrostatic
innovations
16 BA-e-3010-0408_KNH34
3.8 Digital interface
The generators and remote controls to be networked are connected to the system bus in parallel. The dual design of the bus connection (socket and plug) to the generator and the remote control allows the bus to be looped through from component to component without sub-distribution. The com-ponents may be arranged in any sequence. If one component is discon-nected from the bus, the bus will be closed again by linking the coupling and the plug.
Bus front and bus end must be fitted with a terminating connector.
Socket, female Socket, male
Fig. 9:Pin assignment CAN bus female/male
PIN 1 = CAN highPIN 2 = CAN GNDPIN 3 = CAN low
Z00
053y
1
2
3 1
2
3
Fig. 10:Connecting cable KS/A = CAN bus
Color coding:1 = white2 = brown3 = green
Z00
055y
123
123
KS/A Schirm/shield/ecran/schermo
Fig. 11:Bus topology (max. 20 appliances)
Z00
163e
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Fernbedienung
RS 232
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Fernbedienung
RS 232
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Fernbedienung
RS 232
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
AbbruchEscape
SollwertSetpoint
HochspannungHigh Voltage
On/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
1st generator
1st remote controlRS 232 interface
3rd remote control
2nd remote control
2nd generator 3rd generator nth generator4th generator
BA-e-3010-0408_KNH34 17
electrostatic
innovations
3.9 Analog interface
The analog interface allows the generator to be integrated into an SPC or into another environment using 0…10 V- or 0…20 mA interfaces.
Caution!Make sure that the signals have been connected correctly to avoid any damage to the generator.The protection fusing of the error signal contact must be provided by the customer.
The following signals are available:
1 +24 V high voltage release: input high voltage release via external 24 V signal. Note: The parameter „Ext. HV ON/OFF“ must be set for „YES“.U = 24 VDC ±10%, I < 20 mA
2 GND high voltage release:input high voltage release via external 24 V signal.
3 Setpoint 0…10 V (input):10 V correspond to maximum output value (30 kV or 5 mA).Note:The parameter „Ext. Setpoint“ must be set on „ON“.Input resistance: 20 kΩ
4 Setpoint 0…20 mA (input):20 mA correspond to maximum output value (30 kV or 5 mA).Note:The parameter „Ext. Setpoint“ must be set on „ON“.Load: 220 Ω
Fig. 12:Pin assignment, analog interface
Z00
054y
2
3
4 5
6
7
8
9
1
electrostatic
innovations
18 BA-e-3010-0408_KNH34
5 Actual value I = 0…20 mA (output):0 mA corresponding to 0 mA, 20 mA correspond to 5 mA output current.Max. load: 500 Ω
6 Actual value U = 0…20 mA (output):0 mA corresponding to 0 kV, 20 mA correspond to 30 kV output voltage.Max. load: 500 Ω
7/8 Floating contact (error signal contact):Output depending on parameter „Limit Signal“:1st case: „Limit Signal = NO“: Contact opens in the event of malfunction (see chap. 7).2nd case: „Limit Signal = YES“: Contact opens in the event of malfunction and when reaching current or voltage limit. Max. 24 V / 0.5 A DC / AC
9 GND for setpoint and actual values.
Fig. 13:Connecting cable for analog inter-face KS/B
Color coding:1 = white2 = brown3 = green4 = yellow5 = gray6 = pink 7 = blue8 = red9 = black
Z00
056y
123456789
KS/B Schirm/shield/ecran/schermo
BA-e-3010-0408_KNH34 19
electrostatic
innovations
4. Operation
4.1 Start-up
Warning!Depending on the parameter setting „Auto Start“ high voltage may be applied immediately after switching on the supply voltage. Before switching on the unit the user must make sure that the installation has been carried out correctly and that the connections are correct. If yes, the supply voltage may be switched on.Use the rocker switch to switch on the high voltage generator. The display message signals the proper operation of the unit.The generator operates either in the operating mode „voltage constant“ or „current constant“.
If all necessary operating parameters have been correctly set, high vol-tage may be released via the Voltage key. The LED below the key will light up. High voltage is now applied at the electrode bars or at the high voltage output.The display is used to control the output voltage and the output current.
In the Voltage Constant mode, the setpoint value of the voltage is dis-played in the top line, and the actual value of the current is displayed in the bottom line. In the Current Constant mode, the setpoint value of the current is dis-played in the top line, and the actual value of the voltage is displayed in the bottom line.
Notes about the operation of the generator KNH34/W:When operating with the remote control ESC the keypad of the generator is locked. Should the remote control fail or the CAN bus link be disrupted, the keypad of the generator will be automatically activated after a delay of 5 seconds.If the remote control fails or the CAN bus link is disrupted during the operation of the system, high voltage is switched off automatically. After the keypad of the generator has been activated, the high voltage can be switched on and off directly at the generator.
Display (High voltage Off) SETPOINT 30.0 kV generator off
Display (High voltage On) VOLTAGE 20.0 kVcurrent 1.23 mA
electrostatic
innovations
20 BA-e-3010-0408_KNH34
4.2 User concept
The high voltage generator is operated by means of five operating keys located in the front panel and a two-line display (see fig. 14).
The display signals parameters, values and error messages in plain text. Several languages are available for menu operation.
Fig. 14:Operator interface
AbbruchEscape
SollwertSetpoint
SpannungVoltage
activ/active
VOLTAGE 20.0 kVcurrent 1.23 mA
Abort currently entered values and settings by striking the key „Abbruch/Escape“. If, during setting, no key is activated for longer than 10 seconds, the generator auto-matically returns to the actual value display. This return is treated like an escape.After aborting a programming session, the generator con-tinues to operate with the last valid setting.The Escape key also serves as error acknowledgement (see chap. 7).
Use the key „Sollwert/Setpoint“ to 1) modify the current parameter and 2) to store the set value or the selection after changing the parameter.This key therefore releases a value for modification and allows it to be stored after modification.
The key „Spannung/Voltage“ enables the high voltage. If the high voltage is active, the LED below the lettering lights up.The high voltage may only be enabled if no windows for operating parameter settings are active and if no error message is displayed.
Use both arrow keys to modify numerical values or selecting a variety of options.
AbbruchEscape
SollwertSetpoint
SpannungVoltage
activ/active
BA-e-3010-0408_KNH34 21
electrostatic
innovations
4.3 Overview of functions with options and default settings
Note! Selected operating parameters and setpoints are stored in the EEPROM where they are maintained even in case of mains power failures.
Function Description Setting options Default setting
Setpoint XX.X kV
Setting the output voltage in the „voltage constant“ operating mode.
0.0…30.0 kVin 0.1 kV increments
0.0 kV
Setpoint Y.YY mA
Setting the output current in the „current constant“ operating mode.
0.00…5.00 mA in 0.01 mA increments
0.00 mA
PASSWORD Request for password entry to mo-dify the operating parameters. After entering the password, the menu for modifying/setting the operating parameters will open automatically.The operating parameters are listed below.
Password entry Password:Voltage key2 x key 1 x key Setpoint key
Mode Setting the operating mode. „voltage constant“„current constant“
„voltage constant“
Umax XX.X kV Setting the maximum output voltage in the „voltage constant“ operating mode.
0.0…30.0 kVin 0.1 kV increments
30.0 kV
Imax Y.YY mA Setting the maximum output current in the „current constant“ operating mode.
0.00…5.00 mA in 0.01 mA increments
5.00 mA
Limit XX.X kV Setting the voltage limit in the „current constant“ operating mode.
0.0…30.0 kVin 0.1 kV increments
30.0 kV
Limit Y.YY mA Setting the current limit in the „voltage constant“ operating mode.
0.00…5.00 mA in 0.01 mA increments
5.00 mA
Limit mode If the selected current or voltage limit is exceeded, the generator is switched off or the output value is limited.
limitswitch off
limit
Limit Signal When reaching a current or voltage limit, a signal may be transmitted via the status relay.
YES/NO
NO
Change setpoint
Modification of the setpoint for vol-tage or current may be inhibited.
permittedinhibited
permitted
electrostatic
innovations
22 BA-e-3010-0408_KNH34
AUTO Automatic or manual release of high voltage after mains power break.
OFFON
OFF
Ramp time The ramp time determines the time in which the output voltage reaches its setpoint.
0…9.0 seconds 3 s
Bus address If several generators are connected to a digital remote control, a definite address must be assigned to each generator.
00…20 00 (bus not active)
Generator type Allows the definition of functional groups which are then specifically addressed via a remote control.
KNH34FolderGroup 1Group 2Group 3
KNH34
Ext. Setpoint This setting defines if the setpoint for voltage or current is modifiable via the analog interface or via the keypad/CAN bus.
OFFON
OFF
Language Defines the language version of the text output on the display.
German, English, French, Spanish, Italian
German
ext. HV ON/OFF
This setting defines if the high voltage is to be enabled via an exter-nal 24 V signal.In this case, enabling can neither be done via the Voltage key nor via the external Setpoint.
NOYES
NO
Release via ext. Setpoint
This setting defines if the high voltage is to be enabled via an exter-nal Setpoint.In this case, enabling can neither be done via the Voltage key nor via the external 24 V signal.
NOYES
NO
Function Description Setting options Default setting
BA-e-3010-0408_KNH34 23
electrostatic
innovations
4.4 Selecting the output voltage
SETPOINT 30.0 kVgenerator off
With the unit in the „voltage constant“ mode and with high voltage inactive, the opposite display appears.
Activate setpoint setting with the Setpoint key.
SETPOINT 30.0 kVgenerator off
The line „Setpoint“ blinks.
Use the arrow keys to select the desired set-point of the output voltage.
Note!If an arrow key is kept pressed down, the setpoint will be changed in increments of 1 kV each. Pressing and releasing the key will change the setpoint in increments of 0.1 kV.
The newly selected value will be accepted via the Setpoint key. Abort resetting by pressing the Escape key. The setpoint will not be changed.
SETPOINT 20.0 kV generator off
Display
Activate the output voltage via the Voltage key. High voltage is present at the output, current flows.
VOLTAGE 20.0 kVcurrent 1.23 mA
Display
SollwertSetpoint
SollwertSetpoint
SpannungVoltage
activ/active
electrostatic
innovations
24 BA-e-3010-0408_KNH34
4.5 Selecting the output voltage during operation
VOLTAGE 20.0 kVcurrent 1.23 mA
With the unit in the „voltage constant“ mode and with active high voltage, the opposite display appears.
Activate setpoint setting during operation with the Setpoint key.
setpoint 20.0 kVact. value 20.0 kV
Setpoint blinks.The output voltage of the actual values con-tinues to be available at the output.
Use the arrow keys to select the setpoint.
The selected value will be accepted at the out-put by pressing the Setpoint key.Abort resetting by pressing the Escape key. The setpoint will not be changed.
SollwertSetpoint
SollwertSetpoint
BA-e-3010-0408_KNH34 25
electrostatic
innovations
4.6 Selecting the output current
SETPOINT 2.00 mAgenerator off
With the unit in the „current constant“ mode and with high voltage inactive, the opposite display appears.
Activate setpoint setting with the Setpoint key.
SETPOINT 2.00 mAgenerator off
The line „Setpoint“ blinks.
Use the arrow keys to select the desired set-point of the output current.
Note!If an arrow key is kept pressed down, the setpoint will be changed in increments of 0.1 mA each. Pressing and releasing the key will change the setpoint in increments of 0.01 mA.
The newly selected value will be accepted via the Setpoint key.Abort resetting by pressing the Escape key. The setpoint will not be changed.
SETPOINT 3.05 mA generator off
Display
Activate the output current via the Voltage key. High voltage is present at the output, current flows.
CURRENT 3.05 mAvoltage 23.4 kV
Display
SollwertSetpoint
SollwertSetpoint
SpannungVoltage
activ/active
electrostatic
innovations
26 BA-e-3010-0408_KNH34
4.7 Selecting the output current during operation
CURRENT 3.05 mAvoltage 23.4 kV
With the unit in the „current constant“ opera-ting mode and with high voltage active, the opposite display appears.
Activate the setpoint setting during operation with the Setpoint key.
Setpoint 3.05 mAact. value 3.05 mA
Setpoint blinks.The output voltage of the associated output current continues to be available at the output.
Use the arrow keys to select the desired set-point.
The selected value will be accepted at the output via the Setpoint key.Abort resetting by pressing the Escape key. The setpoint will not be changed.
SollwertSetpoint
SollwertSetpoint
BA-e-3010-0408_KNH34 27
electrostatic
innovations
4.8 Selecting the operating parameters
The above described functions involved in changing the setpoint can be carried out by the user without entering a password.The parameters affecting the operating conditions of the application are only accessible via a password.After entering the password, the following parameters may be adjusted and will be listed automatically in sequence in the menu:• Operating mode• Maximum output voltage/current • Voltage/current limit• Limiting mode (Not available for all versions)• Output limiting signal• Modify setpoint• Automatic start (Not available for all versions)• Ramp time• Bus address• Generator type (Not available for all versions)• External setpoint• Language• External high voltage release• Release via external Setpoint voltage (Not available for all versions)• Software status (display only)
Caution!Modifications of the parameters using passwords may only be carried out by authorized personnel.
Note!Use the Escape key to abort the entry. No changes will be made to the current parameters. Setting the operating parameters will be terminated and the system changes back to the setpoint display. Parameter changes which have already been acknowledged with the Set-point key will remain.
electrostatic
innovations
28 BA-e-3010-0408_KNH34
4.8.1 Entering the password
The password may only be entered with the high voltage disabled.
Programming is now released. This status will be shown by the display message „Operating mode“.
4.8.2 Selecting the operating mode
The generator may be operated in either the „current constant“ or the „voltage constant“ mode. A previously defined current or voltage will be kept constant within the operating limits of 30 kV or 5 mA respectively, even if operating conditions change.
This is followed by the next display message: Select „voltage maximum“ or „current maximum“.
SETPOINT 30.0 kVgenerator off
Display
+Keep the key „Increase value“ pressed and press the Setpoint key at the same time.
PASSWORD! !
The password comprises entering the following key commands:
Voltage key
2 x „Lower value“ key
„Increase value“ key
Setpoint key
Operating mode! const. voltage !
Display
Select using the arrow keys.
Operating mode! const. current !
Display
Acknowledge the selected operating mode with the Setpoint key.
SollwertSetpoint
SpannungVoltage
activ/active
SollwertSetpoint
SollwertSetpoint
BA-e-3010-0408_KNH34 29
electrostatic
innovations
4.8.3 Selecting maximum values for voltage and current
If the generator is in the operating mode „voltage constant“, a maximum high voltage rating as required by the application may be selected. The appropriate maximum output current may be selected in the operating mode „current constant“. This value cannot be exceeded when setting the setpoint.This arrangement allows the generator to be adapted to a wide variety of electrode bar configurations and operating modes: example: Web Adhesion: Umax = 20 kV.
E.g. Operating mode „voltage constant“:
In case of „voltage constant“, setting the current maximum is analogous to the above steps.
This is followed by the next display message: Select „current limit“ or „voltage limit“.
Umax 30.0 kV! generator off !
Display
Change the value of the maximum voltage via the arrow keys.
Umax 20.0 kV! generator off !
Display
Acknowledge the selected maximum voltage with the Setpoint key.
SollwertSetpoint
electrostatic
innovations
30 BA-e-3010-0408_KNH34
4.8.4 Selecting voltage or current limits
If the generator is in the operating mode „voltage constant“, a maximum current (the current limit) may be selected. The appropriate voltage limit may be selected in the operating mode „current constant“. This will pre-vent the generator from delivering uncontrolled energy to the consumer.
E.g. Operating mode „voltage constant“:
In case of „current constant“, setting the voltage limit is analogous to the above steps.
This is followed by the next display message: Select „limit mode“.
4.8.5 Selecting the limit mode
Depending on application it might be useful to disable or limit the genera-tor when exceeding the previously selected current or voltage limit. If „switch off“ is selected, the generator will be switched off when reaching the current or voltage limit.
This is followed by the next display message: Output Limit Signal.
limit 5.00 mA! generator off !
Display
Change the current limit values with the arrow keys.
limit 3.00 mA! generator off !
Display
Acknowledge the selected current limit with the Setpoint key.
limitation: type! limiting !
Display
Select the limit mode with the arrow keys.
limitation: type! switch off !
Display
Acknowledge the selected limit mode with the Setpoint key.
SollwertSetpoint
SollwertSetpoint
BA-e-3010-0408_KNH34 31
electrostatic
innovations
4.8.6 Selecting Output Limit Signal
If the current or voltage limit is reached, the generator may transmit a sig-nal during limiting. This signal will be transmitted to the status relay which will drop when reaching the limit.
This is followed by the next display message: Change Setpoint.
4.8.7 Selecting Change Setpoint
In particularly critical applications where the selected setpoint voltage or current must be altered, this option may be used to determine the defined output voltage or output current.
This option used in combination with the remote control prevents unde-sirable or unauthorized setpoint modifications on the generator. The set-point may be modified via the remote control.
This is followed by the next display message: Automatic Start.
limit. signal! active? YES !
Display
Select limit signal YES or NO with the arrow keys.
limit. signal! active? NO !
Display
Acknowledge the selected option with the Set-point key.
change setpoint! enabled !
Display
Use the arrow keys to select Change Setpoint enabled or Change Setpoint disabled.
change setpoint! disabled !
Display
Acknowledge the selected option with the Set-point key.
SollwertSetpoint
SollwertSetpoint
electrostatic
innovations
32 BA-e-3010-0408_KNH34
4.8.8 Selecting Automatic Start after mains power failure
Use this option to select if the generator is to start automatically after a mains power failure or if the high voltage is to be set manually.
This is followed by the next display message: Ramp Time.
Warning!If the automatic start is ON, high voltage applies at once immediately after the supply voltage to the generator is switched on.
auto start! OFF !
Display
Use the arrow keys to select the automatic start of high voltage ON or OFF.
auto start! ON !
Display
Acknowledge the selected option with the Set-point key.
SollwertSetpoint
BA-e-3010-0408_KNH34 33
electrostatic
innovations
4.8.9 Selecting the Ramp Time
After releasing the high voltage via the Voltage key, the voltage will rise to its preselected setpoint within an adjustable period (the ramp time). The ramp time selection range is between 0…9 seconds.
This option is of significance in externally clocked operation via the high voltage release input or in applications requiring a defined rate of voltage rise.
This is followed by the next display message: Bus Address.
Note!When selecting the setting „0“ the high voltage is moved to its setpoint within the shortest possible time. Depending on load, reaching 30 kV may take 0.5 seconds in the „voltage constant“ mode and as much as 1 second in the „current constant“ mode (this time is reduced for smaller setpoint values).
"Voltage constant" mode: If the generator switches to limit operation during the run-up, the ramp time may be as long as 2 seconds.
„Current constant“ mode:If the generator switches to limit operation during the run-up, the limit value may overshoot briefly and settle after about 2 seconds. With a ramp time larger than 0, overshooting is not expected.
ramp time! 3 s !
Display
Use the arrow keys to set the ramp time.
ramp time! 5 s !
Display
Acknowledge the selected value with the Set-point key.
SollwertSetpoint
electrostatic
innovations
34 BA-e-3010-0408_KNH34
4.8.10 Selecting the bus address
When operating one or more generators over the same remote control, a definite address must be selected for each generator connected. Select-able addresses range from 00…20. Address 00 is the default setting set in the factory. With this setting the generator neither responds to bus signals, nor does it transmit any such signals. This means that individual genera-tors integrated in a bus formation can be disabled.
This is followed by the next display message: Generator Type.
4.8.11 Selecting the generator type
Up to 5 different functional groups can be defined by selecting a generator type. This will allow the user to address selective generators via a remote control and to set individual setpoints or group setpoints. The following predefined function groups:• KNH34• Folder
as well as three free groups are available.
This is followed by the next display message: External Setpoint.
bus address! 00 !
Display
Use the arrow keys to select the bus address.
bus address! 20 !
Display
Acknowledge the selected value with the Set-point key.
generator type! KNH34 !
Display
Use the arrow keys to select the appropriate function group.
generator type! Group 1 !
Display
Acknowledge the selection with the Setpoint key.
SollwertSetpoint
SollwertSetpoint
BA-e-3010-0408_KNH34 35
electrostatic
innovations
4.8.12 Selecting External Setpoint
This setting allows the user to permit setpoint modifications only via the keypad and the CAN bus or via the analog interface. If ON is selected, the generator will accept setpoints only via the analog interface by way of a control voltage 0…10 V or by way of a control current 0…20 mA. Depen-ding on operating mode, the setpoint corresponds to a voltage or current default.
This is followed by the next display message: Language.
4.8.13 Selecting the language
This function may be used to select between 5 different languages for the display messages.The following languages are available:• German (default setting),• English• French• Spanish and• Italian .
This is followed by the next display message: External High Voltage Release.
ext. setpoint! OFF !
Display
Use the arrow keys to select External Setpoint ON or OFF.
ext. setpoint! ON !
Display
Acknowledge the selection with the Setpoint key.
Sprache! deutsch !
Display
Use the arrow key to select the appropriate language.
language! english !
Display
Acknowledge the selection with the Setpoint key.
SollwertSetpoint
SollwertSetpoint
electrostatic
innovations
36 BA-e-3010-0408_KNH34
4.8.14 External high voltage release
This function allows the user to activate the high voltage not only via the Voltage key and the analog Setpoint input, but also via the external 24 V signal. The 24 V input is electrically isolated. Select NO to activate the high voltage via the Voltage key, via the CAN bus or via the analog Set-point input (see "Release via external Setpoint"), select YES to activate the high voltage only via the external 24 V signal.
This is followed by the next display message: Release via ext. Setpoint.
Note!If the external high voltage release is used, the parameter "Release via ext. Setpoint" must be set for NO (see chap. 4.8.15). Also, the high volt-age cannot be enabled in this operating mode via the Voltage key or the CAN bus.
ext. HV ON/OFF! NO !
Display
Use the arrow keys to select YES or NO.
ext. HV ON/OFF! YES !
Display
Acknowledge the selection with the Setpoint key.
SollwertSetpoint
BA-e-3010-0408_KNH34 37
electrostatic
innovations
4.8.15 Release via external Setpoint
This function allows the user to activate the high voltage not only via the Voltage key and the external 24 V signal, but also via the analog Setpoint input. This function can be used, e.g. if only one analog output is available at a remote controlling SPC which controls both the setpoint setting and the high voltage release via the analog interface.The high voltage turn-on threshold is at 10% of the setpoint (correspond-ing to 1 V at the voltage input/pin3 analog interface or to 2 mA at the current input/pin4 analog interface). In this operating mode, this results in a setting range of between 10-100% (3-30 kV / voltage constant resp. 0.5-5 mA/current constant) of the Setpoint.
To be able to activate this function, the parameter must be set for YES and the parameter "Ext. Setpoint" must be set for ON (see chap. 4.8.12.).
This is followed by the next display message with Version number and date.
Note!If the function Release via external Set-point is used, the parameter "ext. HV ON/OFF" must be set for NO (see chap. 4.8.14). Also, the high voltage cannot be enabled in this operating mode via the Voltage key or the CAN bus.
Release via ext.! setpoint : NO !
Display
Use the arrow keys to select YES or NO.
Release via ext.! setpoint : YES !
Display
Acknowledge the selection with the Setpoint key.
SollwertSetpoint
electrostatic
innovations
38 BA-e-3010-0408_KNH34
4.8.16 Version number and date
The last display page in the menu Selecting the Operating Parameters shows the version number and the date of the current software.
4.9 Loading the default settings
When starting the unit for the first time or when operating the mains switch and the Escape key at the same time, the default settings will be loaded from the programme memory.
V 4.41! 30.03.2003 !
Display
Use the Setpoint key to complete the entry of the operating parameters.
MAINS SWITCH +Operate MAINS SWITCH and Escape at the same time.
The default settings will now be loaded.The default settings are shown in the table in chap. 4.3.
SollwertSetpoint
AbbruchEscape
BA-e-3010-0408_KNH34 39
electrostatic
innovations
5. MaintenanceWarning!Electric shock hazard!• Do not carry out any maintenance or repair work without first switching
off the high voltage generator and disconnecting the supply voltage.• The machine which has the units fitted must not be in operation.• Repairs and maintenance work must be carried out by qualified person-
nel only.
High voltage generator
The high voltage generator does not require any special maintenance. Check the appliance for proper function at regular intervals. Keep the cooling ribs clean.
Charging bars
To ensure the proper function of the charging bars, clean weekly with compressed air free of oil and water (max. 6 bar) and a non-metallic brush.
Remove encrusted dirt (e.g. grease, adhesive, ink, etc.) from the charging bars with cleaning gasoline. Do not immerse the electrode bars and the high voltage cable in solvent!
Warning!Risk of deflagration!Wait until the solvent has evaporated before restarting the generator.
Caution!Do not damage the emission tips of the charging bars.
electrostatic
innovations
40 BA-e-3010-0408_KNH34
6. WarrantyThe units are warranted for a period of 12 months provided that the oper-ating conditions have been maintained, that the units have not been tem-pered with and that the units show no mechanical damage.
The warranty applies only if the operating and assembly instructions spec-ified by Eltex have been observed. The warranty period begins on the date of delivery.
In the event of defects occurring during the warranty period, the units or defective components will be repaired at Eltex. Defective components will be replaced and installed free of charge.
If repairs are required at the customer's premises, the costs for sending a technician (travel, travel time, expenses) will be charged to the customer.
BA-e-3010-0408_KNH34 41
electrostatic
innovations
7. TroubleshootingWarning!Electric shock hazard!• Do not carry out any maintenance or repair work without first switching
off the high voltage generator and disconnecting the supply voltage.• The machine which has the units fitted must not be in operation.• Repairs and maintenance work must be carried out by qualified person-
nel only.
Defect/Error Defect/Cause Remedy
Generator cannot be switched on
• Defective fuse.• Supply voltage not con-
nected.
Replace fuse (fuse type see name plate).Connect or activate supply voltage
Error text: 01 Limiter
Limiter set for „switch off“, selected value is exceeded.
• Investigate cause why limit value was exceeded
• If necessary, increase limit value.
Error text: 02 Flash count 1
5 high-power discharges within 20 seconds.
• Reduce output voltage.• Clean electrode bars.(error acknowledgement blocked until cascade has cooled down)
Error text: 03 Flash count 2
Processor measuring range was exceeded.
• Reduce output voltage.• Clean electrode bars.• Check high voltage cables.
Error text: 04 Short-circuit
Short-circuit detected (with a current of >5 mA and a volt-age of <150 V).
Disconnect consumers one after the other and localize short-circuit.
Error text: 05 Missing volt.
Error in high voltage genera-tion.
Notify Eltex Service Department.
Error text: 06 Ext. analog
Error in analog interface during test run.
Occurs only in the test programme.
Error text: 07 HV Relais
Error in analog interfaceduring test run.
Occurs only in the test programme.
Error text: 11 Calibration
Defective or no calibration data in EEPROM.
Notify Eltex Service Department.
Error text:12 EEPROM error
Error in EEPROM. Notify Eltex Service Department.
Error text: 13 +15 V missing
Notify Eltex Service Department.
electrostatic
innovations
42 BA-e-3010-0408_KNH34
Error text: 14 –15 V missing
Notify Eltex Service Department.
Error text: 15 Polar. error
Notify Eltex Service Department
Error text: 16 SYS damaged
System data error,corrected automatically.
If occurring frequently, notify Eltex Service Department.
Error text: 17 CALI damaged
Calibration data error, corrected automatically.
If occurring frequently, notify Eltex Service Department
Error text: 18 General error
General error. Switch appliance off and on again, notify Eltex Service Department
Error text:23 Eprom error
Error in the checksum of the EPROM.
Occurs only in the test program.
After remedying the cause of the malfunction, the generator will be operational again after pressing the Escape key (only errors 01…04).
Defect/Error Defect/Cause Remedy
BA-e-3010-0408_KNH34 43
electrostatic
innovations
8. Technical specifications
Output voltage 0…+30 kV ±0.2 kV DC (accuracy 2% v.E.) (KNH34P__)0…–30 kV ±0.2 kV DC (accuracy 2% v.E.) (KNH34N__)Display resolution 100 V, Adjustable in increments of 100 V
AC component of the output voltage <3% at Umax and Imax
Output current 0…5 mA ±0,05 mA (accuracy 2% v.E.)Display resolution 10 µA, Adjustable in increments of 10 µA
Operating modes Current constant, voltage constant, System deviation <2%
Feedback control I-controller adapting to load
Supply voltage 230 VAC ±10%, 50 Hz (KNH34_2_)115 VAC ±10%, 60 Hz (KNH34_1_)
Fuse See name plate
Power input max. 250 VA
Enclosure Sheet metal steel, 1.5 mm, enamelled, aluminium anodised
Protection class IP 54
Operating ambient temperature +5…+40°C (+41…+104°F)
Storage temperature –20…+70°C (–4…+158°F)
Ambient humidity max. 80% rel. no dewing
Dimensions with wall mounting 410 x 212 x 135 mm (H x W x D)
Weight 10,5 kg
TÜVRheinland
Product SafetygeprüfteSicherheit
electrostatic
innovations
44 BA-e-3010-0408_KNH34
9. Dimensions
Fig. 15:Dimensions high voltage generator KNH34
Z00
373y
AbbruchEscape SollwertSetpoint HochspannungHigh VoltageOn/Off
Hochspannungsgenerator
High Voltage Generator
KNH 34
386
M8
M8
M6
M6
2,5
17041
0
128
330
>100
212
BA-e-3010-0408_KNH34 45
electrostatic
innovations
10. Spare parts list and accessories
Article Article No.
High voltage cable 50 kV, with flexible tubing, precut with mul-tiple-spring wire plug and terminal adapter (specify length, distributor box or consumer) KA/R___Plug analog interface for internal cable diameter 5.5 mm, ext. 7.5 mm (in additional for each 1 x ELM01037 is needed) ELM01036Grounding sleeve for internal cable diameter 5.5 mm, ext. 7.5 mm ELM01037Interface cable analog interface generator, cable ends on cos-tum side open (specify cable length) KS/B___CAN bus cable with CAN bus plug on both ends, 1x male, 1x female (specify cable length) KS/A___Set for preparing the high voltage cable for 30 kV charging bars with flexible tubing PG9 104165Set for preparing the high voltage cable for 60 kV charging bars with flexible tubing PG9 104171Hexagonal crimper, 5.41 mm 102952High voltage distributor box, for max. 4 components KNHV3Fuse clip, mains power cable ELM00545Generator mounting MCH08667Bolts for generator mounting MSR00209Mains power cable Standard (specify cable length) KN/AA___Mains power cable Switzerland (specify cable length) KN/AB___Mains power cable USA (specify cable length) KN/AC___Mains cable without plug, costum side open(specify cable length) KN/AD___Protective cap, high voltage output MCH08542Protective cap, analog interface ELM01114Protective cap, cable box analog interface 101901Protective cap, CAN bus male ELM01115Protective cap, CAN bus female ELM01116Operating instructions (specify language) BA-3010Terminating connector, CAN bus, male BSB10291Terminating connector, CAN bus, female BSB10292Remote control KNHFB
electrostatic
innovations
46 BA-e-3010-0408_KNH34
BA-e-3010-0408_KNH34 47
electrostatic
innovations
electrostatic
innovations
Eltex-Elektrostatik-Gesellschaft mbHBlauenstraße 67, D-79576 Weil am RheinPhone +49 (0) 76 21/ 79 05 - 0Fax +49 (0) 76 21/ 79 05 - 310eMail [email protected] www.eltex.com
Eltex officesand agenciesThe addresses of allEltex agencies can be
found on our website atwww.eltex.com
Z010
07y