Axis Blowers Technicaldata

22
Selection and ordering data 101MG SERIES n o i s n e m i D c i t a t s x a M c i t a t s x a M x a M d e t a R t u p t u O e l g n i S e v r u c No MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg single 50 0.2 200-240 345-415Y 1.0 /0.6Y 6 0 5 0 7 0 6 - 0 4 1 60 0.23 220-275 380-480Y 1.0 /0.6Y 6 1 5 0 8 0 7 - 0 5 1 single 50 6 0 5 0 7 0 6 - 0 4 3 4 . 1 V 0 4 2 - 0 0 2 2 . 0 60 6 1 5 0 8 0 7 - 0 5 3 . 1 V 0 4 2 - 0 0 2 3 2 . 0 101MG0.2T 101MG0.2M 220 x 200 x 215 220 x 200 x 215 A X I S Performance curve for vacuum pump Performance curve for compressor EGYFOKOZATÚ OLDALCSATORNÁS FÚVÓ Single Stage Side Channel Blower 101MG SERIES 60 50 40 30 20 10 0 −− 60Hz — 50Hz 1 60 50 40 30 40 10 0 0 20 40 60 80 100 120 140 −− 60Hz — 50Hz 1 20 0 20 40 60 80 100 120 140 Nyomás / pressure (mbar rel.) Vákuum / inlet vacuum (mbar rel.) A kapacitások szívó oldali standard állapotú (20 °C és 1013 mbar abs.) leve re vonatkoznak. Tolerancia ±10%. Flow rates refer to air at standard suction conditions of 20° C and 1013 mbar abs. Tolerance on flow rate values ±10%. Kapacitás / suction capacity V (m3/h)

description

Air blower

Transcript of Axis Blowers Technicaldata

  • Selection and ordering data

    101MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    single50 0.2 200-240 345-415Y 1.0/0.6Y 6050706-04

    160 0.23 220-275 380-480Y 1.0/0.6Y 6150807-05

    1 single 50 6050706-0434.1V042-0022.0

    60 6150807-053.1V042-00232.0

    101MG0.2T

    101MG0.2M 220 x 200 x 215

    220 x 200 x 215

    A X I SPerformance curve for vacuum pump Performance curve for compressor

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 101MG SERIES

    60

    50

    40

    30

    20

    10

    0

    60Hz 50Hz

    1

    60

    50

    40

    30

    40

    10

    00 20 40 60 80 100 120 140

    60Hz 50Hz

    1

    20

    0 20 40 60 80 100 120 140

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    Dimensions for installation

    phase Curve A B C D E F G H J K L M N O P Q R

    101MG0.2M 1 1 198 212 85 179 196 220 108 115 100 65 90 40 45 34 G1 60 8.5

    0.2T 3 1

    phase Curve S

    101MG0.2M 1 1 2

    0.2T 3 1

    MODEL

    Xseloh-XZxY'1V1V'VVULEDOM

    911042/021/051x6M71x6M

  • EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 201MG SERIES

    Selection and ordering data

    201MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    A X I SPerformance curve for vacuum pump Performance curve for compressor

    50 0.4 200-240 345-415Y 2.6/1.5Y 0135031021-08

    2 60 0.5 220-275 380-480Y 2.6/1.5Y 0165061051-89201MG0.4T 256 x 246 x 247single

    1

    50 0.4 200-240V 2.7 80 -120 130 53 11

    4 60 0.5 200-240V 3.2 98 -150 160 56 11single201MG0.4M 256 x 246 x 247

    3

    120

    100

    80

    60

    40

    20

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    2 = 4

    120

    100

    80

    60

    40

    20

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    2 = 4

    1 = 3 1 = 3

    40

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A B C D E F G H J K L M N O P Q R

    201MG0.4M 1 3 / 4 246 247 90 205 230 256 133 128 111 83 108 75 71 39 G1 64 10

    111921652 1 / 230.4T

    MODEL

    phase Curve S

    201MG0.4M 1 3 / 4 2.50.4T 3 1 / 2

    Xseloh-XZxY'1V1V'VVULEDOM

    M6 x 17 M6 x 1.5 M25 x 1.5 M25 x 1.5 M16 x 1.5 M6 x 15 0/120/240 140

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

  • Selection and ordering data

    301MG SERIES

    curve Single Output Rated Max Max static Max static DimensionNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1301MG0.5T single

    50 0.55 200-240 345-415Y 2.4/1.7Y 95 -120 130 57245 x 261 x 266

    12

    2 60 0.62 220-275 380-480Y 2.6/1.5Y 110 -120 130 60 12

    3301MG0.5M single

    50 0.55 220-240V 3.7 95 -120 130 57245 x 261 x 266

    12

    60 0.62 220-240V 4.9 110 -120 130 60 12

    A X I S

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 301MG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    120

    100

    80

    60

    40

    20

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    2 = 4

    1 = 3

    120

    100

    80

    60

    40

    20

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    2 = 4

    1 = 3

    4

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    MODEL phase Curve A B C D E F G H J K L M N O P Q R

    301MG0.5M 1 3 / 4 261 266 101 206 228 245 129 97 154 83 105 75 71 42 G1 68 12

    0.5T 3 1 / 2

    MODEL phase Curve S U V V' V1 V1' Y x Z X-holes X

    301MG0.5M 1 3 / 4 3 M8 x 17 M6 x 15 0/120/240 158

    0.5T 3 1 / 2

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

  • Selection and ordering data

    A X I SPerformance curve for vacuum pump Performance curve for compressor

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 401MG SERIES

    240

    200

    160

    120

    80

    40

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    240

    200

    160

    120

    80

    40

    00 40 80 120 160 200 240 280

    60Hz 50Hz

    62 = 8

    4315 =7

    2 = 6

    8

    437

    1 = 5

    401MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    50 0.85 200-240 345-415Y 4.2/2.4Y 5136061061-541

    2 60 0.95 220-275 380-480Y 4.0/2.3Y 5146061081-57150 1.3 200-240 345-415Y 6.6/3.8Y 6136002071-541

    4 60 1.5 220-275 380-480Y 6.9/4.0Y 6146022012-571

    single

    401MG1.3T 292 X 285 X 302

    401MG0.85T 292 X 285 X 302

    5 50 0.85 200-240V 5 145 -150 160 63 16

    6 60 0.95 200-240V 5.8 175 -160 160 64 16

    7 50 1.3 200-240V 7.3 145 -150 180 63 178 60 1.5 200-240V 7.8 175 -180 200 64 17

    single

    401MG0.85M 292 X 285 X 302

    401MG1.3M 292 X 285 X 302

    1

    3

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A B C D E F G H J K L M N O P Q R

    401MG0.85M 1 5 / 6 285 302 115 225 255 292 156 154 120 95 130 70 75 46 G1 68 12

    1.3M 1 7 / 8

    1.3T 3 3 / 4

    MODEL

    phase Curve S401MG0.85M 1 5 / 6 3

    1.3M 1 7 / 8

    0.85T 3 1 / 2

    1.3T 3 3 / 4

    XM6 x 19 M6 x 1.5 M25 x 1.5 M25 x 1.5 M16 x 1.5 M6 x 15 0/120/240 174

    V1 V1' Y x Z X-holes'VVULEDOM

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    3512921 / 2 30.85T

  • Selection and ordering data

    501MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 1.6 200-240 345-415Y 7.5/4.3Y 1246091002-012

    2 60 2.1 220-275 380-480Y 7.6/4.4Y 1207012022-552

    3 50 2.2 200-240 345-415Y 9.7/5.6Y 210 -220 270 64 25

    4 60 2.55 220-275 380-480Y 10.3/6.0Y 255 -260 290 70 25

    501MG1.6T 346 X 334 X 337single

    501MG2.2T 346 X 334 X 337

    5 50 1.5 200-240V 9 210 -190 190 64 24

    6 60 1.75 200-240V 9.5 255 -190 180 70 24 501MG1.5M 346 X 334 X 337single

    A X I S

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 501MG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    300

    250

    200

    150

    100

    50

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    300

    250

    200

    150

    100

    50

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    3 3

    5 =1 4

    26

    4

    26

    51

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    MODEL phase Curve A B C D E F G H J K L M N O P Q R

    501MG1.5M 1 5 / 6 334 337 120 260 295 346 188 175 128 115 155 96 87 48 G2 83 14821581463 1 / 231.6T

    MODEL phase Curve S

    501MG1.5M 1 5 / 6 4

    1.6T 3 1 / 2

    2.2T 3 3 / 4

    200M25 X 1.5 M16 X 1.5 M8 x 20 0/120/240M8 X 17 M16 X 1.5 M25 X 1.5U V V' V1 V1' Y x Z X-holes X

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    2.2T 3 3 / 4

  • Selection and ordering data

    601MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 2.2 200-240 345-415Y 10/5.6Y 9296002012-813

    2 60 2.55 220-275 380-480Y 10.3/6.5Y 9227002012-673

    3 50 3 200-240 345-415Y 12.5/7.2Y 4396092072-813

    4 60 3.45 220-275 380-480Y 12.5/7.3Y 4327032052-673

    5 50 4 345-415 9.5 2496033092-813

    6 60 4.6 345-415 9.5 2427033033-673

    601MG3.0T 411 X 382 X 384

    601MG2.2T 377 X 382 X 384

    single

    601MG4.0T 432 X 382 X 384

    A X I S

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 601MG SERIES

    600

    500

    400

    300

    200

    100

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    600

    500

    400

    300

    200

    100

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    24

    6

    531

    24

    6

    53

    1

    Performance curve for vacuum pump Performance curve for compressor

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A B C D E F G H J K L M N O P Q R

    601MG2.2T 3 382 384 125 290 325 377 185 198 128 140 180 84 109 54 G2 83 15

    5310911143 / 433.0T841112234 5 / 63

    MODEL

    MODEL phase Curve S601MG2.2T 3 4.5

    3.0T 3 3 / 4

    4.0T 3 5 / 6

    XV1' Y x Z X-holesU V V' V1M10 x 20 0/120/240 240

    M32 x 1.5 M32 x 1.5 M32 x 1.5 M32 x 1.5

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    4.0T

    1 / 2

    1 / 2

  • Selection and ordering data

    701MG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 5.5 345-415 13.3 5608023003-035

    2 60 6.3 345-415 13.3 5628043023-026

    3 50 7.5 345-415 16.7 8608083023-035

    4 60 8.6 345-415 17.3 8628004043-026

    701MG5.5T 485 X 442 X 462

    701MG7.5T 485 X 442 X 462single

    A X I S

    EGYFOKOZAT OLDALCSATORNS FV Single Stage Side Channel Blower 701MG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    1200

    1000

    800

    600

    400

    200

    00 80 160 240 320 400 480 560

    60Hz 50Hz

    4

    1200

    1000

    800

    600

    400

    200

    00 80 160 240 320 400 480 560

    60Hz 50Hz

    2

    1 3

    42

    13

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A B C D E F G H J K L M N O P Q R

    701MG5.5T 3 1 / 2 462 470 147 437 462 484 226 241 167 180 220 85 106 60 66 104 14

    7.5T 3 3 / 4

    '1VSevruCesahp701MG5.5T 3 1 / 2 4.5

    7.5T 3 3 / 4

    MODEL

    Y x Z X-holesM10 x 20 0/120/240 273

    X1V'VVUM8 X 20

    MODEL

    AXIS MG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

  • Selection and ordering data

    302SG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 0.7 200-240 345-415Y 3.8/2.2Y 4155042012-882 60 0.83 220-275 380-480Y 3.75/2.15Y 4116052052-301

    3 50 0.7 200-240V 4.5 88 -190 220 55 15

    4 60 0.83 200-240V 5.6 103 -200 220 61 15302SG0.7M

    302SG0.7T 316 X 284 X 270double

    316 X 284 X 270double

    A X I S

    KTFOKOZAT OLDALCSATORNS FV Double Stage Side Channel Blower 302SG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    240

    200

    160

    120

    80

    40

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    24

    3 1

    240

    200

    160

    120

    80

    40

    00 50 100 150 200 250 300 350

    60Hz 50Hz

    2

    1

    4

    3

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A A' B C D E F G H H' J K L M N O P Q

    302SG0.7M 1 3 / 4 284 316 270 45 205 230 316 129 128 106 111 83 108 75 130 39 G1 64

    0.7T 3 1 / 2

    ZxYXaTSRevruCesahp

    5.1x6M04172885.2013 / 41

    0.7T 3 1 / 2

    MODEL

    M6 x 17

    seloh-X'1VVU

    M25 x 1.5 M16 x 1.5 51/171/291

    V' V1

    MODEL

    AXIS SG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    302SG0.7M

  • Selection and ordering data

    402SG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 1.6 200-240 345-415Y 7.5/4.3Y 4266082082-051

    2 60 2.05 220-275 380-480Y 7.6/4.4Y 4296013023-081

    3 50 2.2 200-240 345-415Y 9.7/5.6Y 7266044033-051

    4 60 2.55 220-275 380-480Y 10.3/6.0Y 7296024053-081

    402SG1.6T 401 X 321 X 315

    402SG2.2T

    double

    401 X 321 X 315

    A X I S

    KTFOKOZAT OLDALCSATORNS FV Double Stage Side Channel Blower 402SG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    300

    250

    200

    150

    100

    50

    00 100 200 300 400 500 600 700

    60Hz 50Hz

    300

    250

    200

    150

    100

    50

    00 100 200 300 400 500 600 700

    60Hz 50Hz

    2

    14

    3

    241 3

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A A' B C D E F G H H' J K L M N O P Q

    402SG1.6T 3 1 / 2 321 321 315 58 225 255 401 185 154 154 128 95 130 70 151 46 G1 72

    2.2T 3 3 / 4

    MODEL

    AXIS SG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    ZxYXaTSRevruCesahp5.1x6M471826013211

    2.2T 3 3 / 4

    M6 x 19seloh-X'1VMODEL

    M16 x 1.5 51/171/291M25 x 1.5 M16 x 1.5U V V' V1

    1 / 2402SG1.6T

  • Selection and ordering data

    502SG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 3 200-240 345-415Y 12.5/7.2Y 9327014043-032

    2 60 3.45 220-275 380-480Y 12.5/7.3Y 9347063083-572

    3 50 4 380-415 10 3427094093-032

    4 60 4.6 380-415 9.9 3447084014-572502SG4.0T 499 X 372 X 371

    502SG3.0T 465 X 372 X 371double

    A X I S

    KTFOKOZAT OLDALCSATORNS FV Double Stage Side Channel Blower 502SG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    300

    250

    200

    150

    100

    50

    00 80 160 240 320 400 480 560

    60Hz 50Hz

    300

    250

    200

    150

    100

    50

    00 80 160 240 320 400 480 560

    60Hz 50Hz

    2

    1

    4

    3

    2

    41

    3

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    phase Curve A A' B C D E F G H H' J K L M N O P Q

    502SG3.0T 3 1 / 2 372 411 371 60 260 295 465 190 175 144 135 115 155 98 171 48 55 83

    422994 3 / 43ZxYXaTSRevruCesahp

    42611441 1 / 23

    4.0T 3 3 / 4

    X -holesV V' V1 V1'

    MODEL

    M8x 17ULEDOM

    M8 x 20 192/171/155.1x23Mx4

    AXIS SG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    502SG3.0T

    4.0T

  • Selection and ordering data

    602SG SERIES

    noisnemiDcitatsxaMcitatsxaMxaMdetaRtuptuOelgniSevrucNo MODEL double Freq power voltage current airflow suction pressure Noise L X W X H weight

    stage Hz Kw V A m3/h mbar mbar dB(A) mm Kg

    1 50 2.2 200-240 345-415Y 9.7/5.6Y 2437012022-023

    2 60 2.55 220-275 380-480Y 10.3/6.0Y 2467051071-583

    3 50 3 200-240 345-415Y 12.5/7.2Y 7437062082-023

    4 60 3.45 220-275 380-480Y 12.6/7.3Y 7467002032-583

    5 50 4.3 345-415 10 3537083063-023

    6 60 4.8 345-415 10.4 3567023053-583

    7 50 5.5 345-415 13.3 0737005044-023

    8 60 6.3 345-415 13.3 0767005044-583602SG5.5T 570 X 426 X 424

    602SG3.0T 507 X 426 X 424

    602SG2.2T 473 X 426 X 424

    602SG4.3T 528 X 426 X 424

    double

    A X I S

    KTFOKOZAT OLDALCSATORNS FV Double Stage Side Channel Blower 602SG SERIES

    Performance curve for vacuum pump Performance curve for compressor

    600

    500

    400

    300

    200

    100

    0

    60Hz 50Hz

    600

    500

    400

    300

    200

    100

    00 80 160 240 320 400 480 560

    60Hz 50Hz

    4

    6

    53

    1

    24

    5

    1

    0 80 160 240 320 400 480 560

    2

    7

    8

    3

    7

    6

    8

    Nyoms / pressure (mbar rel.)Vkuum / inlet vacuum (mbar rel.)

    A kapacitsok szv oldali standard llapot (20 C s 1013 mbar abs.) leveJre vonatkoznak. To lerancia 10%.Flow rates refer to air a t standard suction conditions of 20 C and 1013 mbar abs. Tolerance on flow rate values 10%.

    Kapa

    cit

    s / s

    uctio

    n ca

    paci

    ty V

    (m3/

    h)

  • Dimensions for installation

    AXIS SG series can be applied both as a vacuum pump or a compressor in

    continuous operation over the total stated performance curve range. The

    motors are available for the input voltage range of 50 and 60 Hz.

    The blowers protection category is IP 54, temperature class F and they are

    approbated for EC and ROHS. Furthermore they are designed according to DIN

    EN 60 034 / IEC 34-1.

    The side channel blower or exhauster increases the pressure of the aspirated gasby the creation of a series of vortexes in the peripheral toroidal (side) channel. Thevanes force the gas forward and outward, producing a helical gas motion. These machines are used when the required pressure (up to +1000 mbar) or vacuum (down to - 700 mbar) is considerably higher than what can be achieved by a fan. Impeller assembled directly on the motor shaft; No metal to metal contact, thus no internallubrication; Totally uncontaminated and oil-free gas; Dynamically balanced rotatingparts to ensure absolute absence of vibration; Low noise; Virtually maintenance free;Pulsation free discharge; Full die-cast aluminium construction for maximum sturdinessand light weight; 1 year warranty.

    phase Curve A A' B C D E F G H H' J K L M N O P Q

    602SG2.2T 3 1 / 2 426 424 420 63 290 325 473 185 198 164 128 140 180 84 205 54 55 83

    5310917053 / 433.0T841112825 5 / 634.3T

    5.5T 3 7 / 8 154 570 225 167 225 94

    XTSRevruCesahp

    0429215.4511 / 23

    3 3 / 44.3T 3 5 / 65.5T 3 7 / 8

    4 x M 32 x1.5

    V1' Y x Z X -holes

    M810x 20 51/171/291

    V V' V1

    M8x 17 M25x 1.5 M16x 1.5

    U

    MODEL

    MODEL

    602SG2.2T3.0T