AV002 - Henrico...HOFFMAN A-SE4X4X4NK 18" ABOVE LAY-IN CEILING 3/AV800 G J12 CEILING PROJECTION...
Transcript of AV002 - Henrico...HOFFMAN A-SE4X4X4NK 18" ABOVE LAY-IN CEILING 3/AV800 G J12 CEILING PROJECTION...
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
LEGEND NOTES
[A] FLOOR BOXES AND FLOOR PENETRATIONS (GENERAL)FLOOR BOXES AND FINISHED COVERS MAY BE SOLD SEPARATELY. VERIFY COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO ORDERING. VERIFY EXACTLOCATION WITH ARCHITECT PRIOR TO INSTALLATION. IF THE LOCATION OF A FLOOR BOX INDICATED ON THE DRAWINGS CONFLICTS WITH EXISTINGSTRUCTURE, THE CONTRACTOR IS AUTHORIZED TO MOVE THE LOCATION OF THE FLOOR BOX UP TO 6IN. IN ANY DIRECTION TO CLEAR THE OBSTRUCTION. IFTHE LOCATION MUST BE MOVED MORE THAN 6IN. IN ANY DIRECTION, THE CONTRACTOR SHALL CONSULT WITH THE ARCHITECT FOR FURTHER INSTRUCTIONS.
[B] FB1(N1,P1) FLOOR BOX CONFIGURATION (SEE POWER RECEPTACLES NOTE BELOW)WIREMOLD RFB9 FLOOR BOX WITH FINISHED COVER. VERIFY COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO ORDERING. USE THE FIRST SINGLE-GANGCOMPARTMENT FOR POWER. USE SECOND SINGLE-GANG COMPARTMENT FOR VOICE/DATA AND AV, AND RESERVE THE LAST SINGLE-GANG COMPARTMENTAND THE SIX-GANG COMPARTMENT FOR AV ONLY. INSTALL A DUPLEX POWER RECEPTACLE IN THE SINGLE GANG-POWER COMPARTMENT. PROVIDE QTY-2RFB119-3SB BLANK COVER PLATES FOR THE SIX-GANG COMPARTMENT. PROVIDE QTY-1 RFB119-1SB BLANK COVER PLATES FOR THE 2 SINGLE-GANGCOMPARTMENTS. USE MODEL RFB9-OG WHERE APPLICATION IS IN SLAB AT GRADE.
[C] NOT USED
[D] FLAT PANEL DISPLAY BOX J9(N3,P4) CONFIGURATION (SEE POWER RECEPTACLES NOTE BELOW)FSR PWB-100 WALL BOX. INCLUDES NETWORK OUTLET N3 AND POWER RECEPTACLE P4. ASSEMBLY COMES STANDARD WITH QTY-1 LOW VOLTAGE ENTRY BOX.ORDER ADDITIONAL LOW VOLTAGE ENTRY BOX FSR PART NO. PWB-100-CBB. TERMINATE CONDUITS TO UPPER OR LOWER LOW-VOLTAGE ENTRY BOX ASINDICATED ON THE CONDUIT RISER DRAWINGS. ORDER WITH WHITE PAINTABLE COVER.
[E] NOT USED
[F] RACO JUNCTION BOXES W/RAISED DEVICE COVERSPROVIDE A RAISED SINGLE OR TWO DEVICE COVER AS SPECIFIED OF APPROPRIATE DEPTH TO MATCH WALL THICKNESS.
[G] CEILING SUSPENDED VIDEO PROJECTORTHE LOCATION OF THE AUDIOVISUAL, POWER AND NETWORK JUNCTION BOXES IN RELATION TO THE PROJECTION SCREEN IS CRITICAL. FOR VIDEOPROJECTOR INFRASTRUCTURE LAYOUT INFORMATION SEE SHEET AV002 AND REFERENCED DETAILS.
[H] PROJECTION SCREEN LOW VOLTAGE CONTROL SYSTEMPROVIDE A.C. LINE VOLTAGE CONNECTION TO SCREEN CONTROL INTERFACE BUILT INTO MOTORIZED PROJECTION SCREEN HOUSING PER MANUFACTURER'SINSTRUCTION. PROVIDE LOW VOLTAGE WIRING CONNECTION FROM SCREEN CONTROL INTERFACE TO WALL MOUNTED PROJECTION SCREEN WALL SWITCHPER MANUFACTURER'S INSTRUCTION.
[I] NETWORK OUTLETS FOR AUDIOVISUAL SYSTEMSNETWORK OUTLETS SHOWN ON THE DRAWINGS ARE REPRESENTATIVE OF NETWORK CONNECTIVITY REQUIREMENTS IN SUPPORT OF AUDIOVISUAL SYSTEMS.REFER TO THE STRUCTURED CABLING SYSTEM SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION.
[J] POWER RECEPTACLES ADJACENT STANDARD NETWORK WALL OUTLETS (SEE POWER RECEPTACLES NOTE BELOW)N2 STANDARD NETWORK WALL OUTLETS SHOULD HAVE A DUPLEX POWER RECEPTACLE LOCATED WITHIN 36" OF THE TELECOMMUNICATIONS WALL OUTLET.IDEALLY, THE NETWORK OUTLET BOX WILL BE MOUNTED TO ONE SIDE OF A STUD, AND THE POWER BOX TO THE OPPOSITE SIDE OF THE BOX.
[K] POWER RECEPTACLESTECHNICAL POWER RECEPTACLES, INCLUDING THOSE WITHIN FLOOR BOXES, WALL BOXES, OR CEILING BOXES, ARE PROVIDED BY ELECTRICAL AND APPEARON THE ELECTRICAL DRAWINGS. THE TECHNICAL POWER RECEPTACLES ALSO APPEAR ON THE TECHNOLOGY INFRASTRUCTURE DRAWINGS FORCOORDINATION PURPOSES AS THE LOCATION OF TECHNICAL POWER RECEPTACLES IN RELATION TO OTHER TECHNOLOGY INFRASTRUCTURE MAY BECRITICAL. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETE POWER LAYOUTS AND CIRCUITING DETAILS.
GENERAL NOTESSUBSTITUTIONSTHE MANUFACTURER AND MODEL OF JUNCTION BOXES NAMED IN THE TECHNOLOGY SYMBOLS LEGEND HAVE BEEN LISTED TO ESTABLISH THE DESIRED LEVELOF QUALITY AND PERFORMANCE FOR EACH DEVICE. UNLESS OTHERWISE INDICATED, THE INSTALLING CONTRACTOR MAY SUBSTITUTE THESE DEVICES WITHEQUIVALENT PRODUCT BY OTHER MANUFACTURERS.
DEVICE MOUNTINGDEVICE SPECIFIED MOUNTING STYLE ELEVATIONS ARE "ON CENTER" UNLESS OTHERWISE NOTED.
JUNCTION BOX COVERSUNLESS OTHERWISE DIRECTED, ALL JUNCTION BOXES MUST BE PROVIDED WITH A COVER. WHERE RAISED DEVICE COVERS ARE SPECIFIED IN THE SCHEDULE,MATCH COVER DEPTH TO WALL THICKNESS. WHERE JUNCTION BOXES ARE MOUNTED AT OR ABOVE FINISHED CEILING HEIGHT, INSTALL JUNCTION BOX WITHOPEN SIDE FACING DOWN.
CONDUIT RUNS:ALL CONDUIT RUNS SHALL BE STEEL, THIN-WALL ELECTRICAL METALLIC TUBING (EMT) UNLESS OTHERWISE INDICATED. THE USE OF FLEXIBLE CONDUIT IS NOTPERMISSIBLE EXCEPT WHERE INDICATED ON THE DRAWINGS. CONDUIT SIZES AND INTERCONNECTIONS SHALL BE AS INDICATED ON THE DRAWINGS. CONDUITROUTING IS AT CONTRACTOR'S DISCRETION BUT THE CONTRACTOR SHALL PROVIDE A PULL BOX IMMEDIATELY BEFORE AND AFTER ANY CONDUIT RUN SECTIONCONTAINING TWO NINETY-DEGREE TURNS, OR ANY SINGLE RUN EXCEEDING FIFTY FEET IN LENGTH REGARDLESS OF WHETHER PULL BOXES ARE SHOWN ONTHE DRAWINGS OR NOT. ALL CONDUIT RUNS SHALL BE PROVIDED WITH A PULL STRING.
CONDUIT STUBS:PROVIDE A NYLON BUSHING ON ALL CONDUIT STUBS AND NON-TERMINATED CONDUIT ENDS TO PROTECT WIRE PULLS.
GROUNDING:GROUND COMMUNICATIONS SYSTEMS AND EQUIPMENT IN ACCORDANCE WITH ANSI/TIA/EIA-607 GROUNDING STANDARD AND APPLICABLE NEC REQUIREMENTSEXCEPT WHERE THE DRAWINGS OR SPECIFICATIONS EXCEED NEC REQUIREMENTS. ALL RACKS, METALLIC BACKBOARDS, CABLE SHEATHS, METALLIC STRENGTHMEMBERS, SPLICE CASES, CABLE TRAYS, ETC. ENTERING OR RESIDING IN TECHNICAL EQUIPMENT SPACES SHALL BE GROUNDED TO THEIR RESPECTIVEGROUND SYSTEM USING A MINIMUM #6 AWG STRANDED COPPER BONDING CONDUCTOR AND COMPRESSION CONNECTORS. ALL WIRES USED FOR TECHNICALPOWER SYSTEMS GROUNDING PURPOSES SHALL BE IDENTIFIED WITH GREEN INSULATION OR IDENTIFIED AT EACH TERMINATION POINT WITH A WRAP OF GREENTAPE. ALL CABLES AND BUS BARS SHALL BE IDENTIFIED AND LABELED "TECHNICAL POWER SYSTEM GROUND".
FIRESTOPPING:PROVIDE THROUGH-PENETRATION FIRE STOP SYSTEMS TO PREVENT THE SPREAD OF FIRE THROUGH OPENINGS MADE IN FIRE-RATED WALLS OR FLOORS TOACCOMMODATE PENETRATING ITEMS SUCH AS CONDUIT, CABLES AND CABLE RACEWAYS. FIRE STOP SHALL RESTORE FLOOR AND WALL TO ORIGINAL FIRERATED INTEGRITY AND SHALL BE WATERPROOF. THE FIRE STOP SYSTEMS AND PRODUCTS SHALL HAVE BEEN TESTED IN ACCORDANCE WITH UL PROCEDURESAND MATERIALS SHALL BE UL CLASSIFIED AS MATERIALS FOR USE IN THROUGH-PENETRATION FIRE STOPS.
THE FIRE STOP SYSTEM SHALL COMPLY WITH THE NEC AND WITH NFPA 101-LIFE SAFETY CODE (LATEST EDITION) AND SHALL BE MADE AVAILABLE FORINSPECTION BY THE LOCAL INSPECTION AUTHORITIES PRIOR TO CABLE SYSTEM ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THEFIRE RATING OF ALL WALLS AND FLOORS HAVING CABLING PENETRATIONS. COORDINATE SEALANT INSTALLATION WITH WORK OF OTHER TRADES. REFER TOGENERAL AND/OR ELECTRICAL SPECIFICATION SECTIONS FOR FURTHER MATERIAL AND INSTALLATION PARAMETERS. COORDINATE INSTALLATION WITH THEGENERAL CONTRACTOR ON SITE.
FIRE STOP SYSTEMS SHALL BE UL CLASSIFIED TO ASTM E814 (UL1479) AND SHALL BE APPROVED BY A QUALIFIED PROFESSIONAL ENGINEER (P.E.), LICENSED INTHE STATE WHERE THE WORK IS TO BE PERFORMED. A DRAWING SHOWING THE PROPOSED FIRE STOP SYSTEM, STAMPED/EMBOSSED BY THE P.E. SHALL BEPROVIDED TO THE OWNER'S TECHNICAL REPRESENTATIVE PRIOR TO INSTALLING THE FIRE STOP SYSTEM(S).
TECHNOLOGY JUNCTION BOX LEGEND
TYPE
FUNCTION
ENCLOSURE DIMENSIONS
ENCLOSURE DESCRIPTION ENCLOSURE MAKE & MODEL MOUNTING STYLE
REFERENCE
DETAIL
LEGEND
NOTES
SYM STYLE LENGTH WIDTH DEPTH
FB1 FLOOR FLOOR BOX 12-5/8" 14-3/4" 4-1/8" FLOOR BOX WIREMOLD RFB9 FLUSH WITH FINISHED FLOOR 4/AV800 A + B
J1 - NOT USED - - - - - - - -
J2 WALL EQUIPMENT RACK PULL BOX 12" 12" 4" PAINTED SCREW COVER PULL BOX HOFFMAN A-SE12X12X4Nk 18" AFF - FLUSH - -
J3 WALL AV I/O PANEL - SMALL 4-11/16" 4-11/16" 2-1/8" PULL BOX W/RAISED TWO-DEVICE COVER RACO 259 18" AFF - FLUSH (UNLESS OTHERWISE INDICATED) - F
J4 - NOT USED - - - - - - - -
J5 WALL CONTROL PANEL 4-11/16" 4-11/16" 2-1/8" PULL BOX W/RAISED TWO-DEVICE COVER RACO 259 48" AFF - FLUSH - F
J6 WALL PROJECTION SCREEN CONTROL SWITCH 2-1/8" 4" 2-1/8" UTILITY BOX RACO 674 48" AFF - FLUSH 1/AV800 &5/AV801 H
J7 WALL LOUDSPEAKER 4-11/16" 4-11/16" 2-1/8" PULL BOX W/RAISED SINGLE-DEVICE COVER RACO 259 102" AFF - FLUSH 2/AV800 F
J8 WALL CAMERA 4-11/16" 4-11/16" 2-1/8" PULL BOX W/RAISED TWO-DEVICE COVER RACO 259 96" AFF - FLUSH - F
J9 WALL FLAT PANEL DISPLAY WALL BOX ASSEMBLY 10-15/16" 7-3/8" 3-9/16" PULL BOX FSR PWB-100 FLAT PANEL DISPLAY WALL BOX 44" AFF - FLUSH (UNLESS OTHERWISE INDICATED) 1/AV801 D
J10 CEILING CONSOLIDATION PULL BOX 16" 16" 4" PAINTED SCREW COVER PULL BOX HOFFMAN A-SE16X16X4Nk 18" ABOVE LAY-IN CEILING - -
J11 CEILING VIDEO PROJECTOR PULL BOX 4" 4" 4" PAINTED SCREW COVER PULL BOX WITHOUTKNOCKOUTS HOFFMAN A-SE4X4X4NK 18" ABOVE LAY-IN CEILING 3/AV800 G
J12 CEILING PROJECTION SCREEN CONTROL BOX 7-5/8" 3-3/4" 3-5/8" - DRAPER LVC-III CONTROL MODULE COORDINATE W/ PROJECTION SCREEN 1/AV800 &5/AV801 H
J13 - NOT USED - - - - - - - -
J14 CEILING LOUDSPEAKER PULL BOX 4-11/16" 4-11/16" 2-1/8" PULL BOX W/FLAT COVER RACO 259 18" ABOVE LAY-IN CEILING 3/AV801 -
TECHNOLOGY NETWORK JUNCTION BOX LEGEND
TYPE
FUNCTION
ENCLOSURE DIMENSIONS
ENCLOSURE DESCRIPTION ENCLOSURE MAKE & MODEL MOUNTING STYLE
REFERENCE
DETAIL
LEGEND
NOTES
SYM STYLE LENGTH WIDTH DEPTH
N1 FLOOR NETWORK OUTLET - IN FLOOR BOX - -- - FLOOR BOX INDICATED BY FB-NUMBER COORDINATE W/ASSOCIATED FLOOR BOX INSTALL IN FLOOR BOX PER MANUFACTURER DIRECTIONS 4/AV800 B + I
N2 WALL NETWORK OUTLET - STANDARD 4-11/16" 4-11/16" 2-1/8" PULL BOX W/RAISED SINGLE-DEVICE COVER RACO 259 18" AFF - FLUSH (UNLESS OTHERWISE INDICATED) - F + I + J
N3 WALL NETWORK OUTLET - FLAT PANEL DISPLAY - - - - - PART OF J9 1/AV801 D + I
N4 - NOT USED - - - - - - - -
N5 - NOT USED - - - - - - - -
N6 CEILING NETWORK OUTLET - VIDEO PROJECTOR PULLBOX 4-11/16" 4-11/16" 2-1/8" PULL BOX W/BLANK COVER RACO 259 18" ABOVE LAY-IN CEILING - ADJACENT J11 3/AV800 G + I
TECHNOLOGY POWER LEGEND
TYPE
FUNCTION VOLTS AMPS NEMA DESCRIPTION ADDITIONAL REQUIREMENTS MOUNTING STYLE
REFERENCE
DETAIL
LEGEND
NOTES
SYM STYLE
P1 FLOOR TECHNOLOGY SYSTEMS FLOOR BOX POWER 120V 20A 5-20R DUPLEX RECEPTACLE INSIDE FLOOR BOX ISOLATED GROUND COORDINATE WITH FLOOR BOX 4/AV800 B + K
P2 WALL TECHNOLOGY SYSTEMS POWER 120V 20A 5-20R DUPLEX RECEPTACLE ISOLATED GROUND 18" AFF - FLUSH - K
P3 WALL TECHNOLOGY SYSTEMS POWER 120V 20A 5-20R DOUBLE DUPLEX RECEPTACLES DEDICATED CIRCUIT - ISOLATED GROUND 18" AFF - FLUSH (UNLESS OTHERWISE INDICATED) - K
P4 WALL FLAT PANEL DISPLAY POWER 120V 20A 5-20R DUPLEX RECEPTACLE ISOLATED GROUND PART OF J9 1/AV801 D + K
P5 CEILING VIDEO PROJECTOR POWER - PULL BOX 120V 20A 5-20R DOUBLE DUPLEX RECEPTACLES DEDICATED CIRCUIT - ISOLATED GROUND 18" ABOVE LAY-IN CEILING - ADJACENT J11 3/AV800 G + K
P6 CEILING MOTORIZED PROJECTION SCREEN POWER 120V 20A - WORKBOX W/PWR CKT - TERMINATE AT J12 PER MFG INSTRUCTIONS 1/AV800 &5/AV801 K
TECHNOLOGY SYMBOLS LEGEND
Jx,Jx
NOTES:1. FOR J-NUMBER REFER TO TECHNOLOGY JUNCTION BOX LEGEND.2. FOR N-NUMBER REFER TO TECHNOLOGY NETWORK JUNCTION
BOX LEGEND.3. FOR P-NUMBER REFER TO TECHNOLOGY POWER LEGEND.
Jx,Nx Nx,NxOR OR
JUNCTION BOX AUDIOVISUAL ONLYJUNCTION BOX NETWORK ONLYPOWER OUTLETJUNCTION BOX CONTAINING NETWORK OUTLETJUNCTION BOX CONTAINING POWER OUTLETJUNCTION BOX CONTAINING NETWORK & POWER OUTLETSFLOOR BOXFLOOR BOX CONTAINING NETWORK OUTLETFLOOR BOX CONTAINING POWER OUTLETFLOOR BOX CONTAINING NETWORK & POWER OUTLETS
JxNxPx
Jx(Nx)Jx(Px)
Jx(Nx,Px)FBx
FBx(Nx)FBx(Px)
FBx(Nx,Px)
INFRASTRUCTURE GROUP TYPEREFER TO INFRASTRUCTURE GROUPTYPE LEGEND ON PLANS FOR MOREINFORMATION.
DISPLAY TYPE - REFER TO PROJECTIONSCREEN LEGEND AND DISPLAY LEGENDFOR MORE INFORMATION.
CONDUIT RISERDETAIL# / SHEET #
ELEVATION SYMBOLDETAIL# / SHEET #
SECTION SYMBOLDETAIL# / SHEET #
X
X
RISER
#AV000
AV000 #
#AV000
N2A
SYMBOL DESIGNATESFLOOR, WALL OR CEILING
REFER TO TELECOMMUNICATIONSCABLING LEGEND FOR MORE
INFORMATION ON CABLE PULL TYPE
DENOTES DEVICES WHICH FALL ONTHE SAME VERTICAL PLANE
N-NUMBER DESIGNATESBOX TYPE & MTG STYLE
LETTER DESIGNATESCABLE PULL TYPE
CEILING "DROP IN" PUBLIC ADDRESS SPEAKER
RECESSED PUBLIC ADDRESS SPEAKER
SURFACE MOUNT PUBLIC ADDRESS SPEAKER
Dx
SECURITY DOOR DESIGNATOR - REFER TO SECURITYDOOR SYMBOL LEGEND FOR MORE INFORMATION.DIAMOND DESIGNATES NON-SECURE ENTRY SIDE OF DOOR."Dx" DESIGNATES SECURITY DOOR TYPE.
SECURITY CAMERA DESIGNATOR - REFER TO SECURITYCAMERA LEGEND FOR FURTHER INFORMATION.
CABLE BASKET - REFER TO PLANS FOR SIZE
CONDUIT - REFER TO PLANS FOR SIZE
Cx
S CEILING RECESSED LOUDSPEAKER - SHOWN FORCOORDINATION PURPOSES ONLY
JUNCTION FLOOR BOX
P
P
P
JUNCTION WALL BOX
JUNCTION CEILING BOX
NETWORK FLOOR BOX
NETWORK WALL BOX
NETWORK CEILING BOX
FLOOR POWER CIRCUIT
FLOOR POWER DUPLEX RECEPTACLE
FLOOR POWER DBL-DUPLEX RECEPTACLE
WALL POWER CIRCUIT
WALL POWER DUPLEX RECEPTACLE
WALL POWER DBL-DUPLEX RECEPTACLE
CEILING POWER CIRCUIT
CEILING POWER DUPLEX RECEPTACLE
CEILING POWER DBL-DUPLEX RECEPTACLE
AV001
AUDIOVISUAL SYMBOLS
AND LEGENDS
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV002
(D2) SEE NOTE 3
(CW)
(IW) (IH)
(IW)
CEILING MOUNTED VIDEO PROJECTION SCREEN (TYP.)
( AUDIENCE VIEW )
PROJECTION SCREEN MOTOR ROLLER HOUSING
CEILING RECESSEDMOTORIZED
PROJECTION SCREEN
CEILING MOUNTED VIDEO PROJECTION SCREEN &
PROJECTOR LAYOUT (TYP.) - PLAN VIEW
(SCREEN CENTERLINE)
(D1) SEE NOTE 1 & 2
6"~12" (TYP.)
P
P LV
(CD)
J12/P6
P5J11N6
(CW)
(D2) SEE NOTE 3
(IH)
(D1) SEE NOTES 1 & 2
PP5 J11 N6
CEILING MOUNTED VIDEO PROJECTION SCREEN &
PROJECTOR LAYOUT (TYP.) - SECTION
90°"
PROJECTION SCREEN / VIDEO PROJECTOR RELATIONSHIP NOTES:
1. [D1]: !!! CRITICAL DISTANCE !!! - D1 IS THE DISTANCE FROM THE PROJECTION SCREEN SURFACE TO THE CENTER OF THE PROJECTOR CEILING MOUNT ASSEMBLY. IF DISTANCE (D2) MUST BE INCREASED OR DECREASED FOR ANY REASON, DISTANCE (D1) MUST BE MAINTAINED.
2. [D1x]: IS THE ALLOWABLE +/- VARIANCE IN DISTANCE OF [D1] TO ACCOMMODATE STRUCTURAL OR OTHER OBSTRUCTIONS. EXAMPLE: THE PROJECTOR MOUNT FOR ROOM 106, PROJECTION SCREEN TYPE-B, CAN BE LOCATED BETWEEN 162" (D1-D1X) TO 198" (D1+D1X) ON SCREEN CENTERLINE FROM THE PROJECTION SCREENSURFACE. CONTACT THE AUDIOVISUAL CONSULTANT IF CONDITIONS WILL NOT PERMIT THE PROJECTOR MOUNT TO BE LOCATED WITHIN THE SCREEN-TO-MOUNT DISTANCE SPECIFIED BY [D1] AND VARIABLE [D1x].
3. [D2]: IS THE ESTIMATED DISTANCE FROM THE PROJECTION WALL TO THE CENTER OF THE PROJECTOR CEILING MOUNT ASSEMBLY. ALSO SEE NOTE 1.
4. [BLACK DROP]: !!! CRITICAL DISTANCE & PROJECTED LIGHT PATHWAY !!! - THE LENGTH OF THE BLACK DROP IS MEASURED BY THE DISTANCE FROM THE BOTTOM SURFACE OF THE PROJECTION SCREEN CASE TO THE TOP OF THE SCREEN IMAGE VIEWING AREA. IF THE LENGTH OF BLACK DROP MUST BE INCREASED ORDECREASED FOR ANY REASON, THE PROJECTOR WILL NEED TO BE RAISED OR LOWERED BY AN EQUAL AMOUNT.
5. THE PROJECTOR MUST ALWAYS HAVE CLEAR VIEW OF THE ENTIRE SCREEN IMAGE AREA WITHOUT OBSTRUCTIONS.
6. PROJECTOR POWER, AV, & NETWORK PULL BOX LOCATIONS RELATIVE TO THE PROJECTOR SUPPORT MAY VARY BY SUPPORT & CEILING TYPE. VERIFY BEFORE INSTALLATION.
7. PROJECTION SCREEN POWER AND LOW VOLTAGE JUNCTION BOX (TYPICAL). LOCATE ON THE SAME SIDE OF THE SCREEN AS SCREEN ELECTRICAL CONNECTIONS WHICH MAY VARY BY SCREEN TYPE. VERIFY LOCATION PRIOR TO INSTALLATION.
90°"
6"~12" (TYP.) 18" (TYP.)
BOTTOM OF IMAGE HEIGHT ABOVE FINISHED FLOOR. SEE ELEVATION DETAILS.
SCALE:1
AV002TYPICAL PROJECTION SCREEN, PROJECTOR SUPPORT & INFRASTRUCTURE LAYOUT
NTS
PROJECTION SCREEN TYPE LEGEND
ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS
TYPE
IMAGE SIZE CASE SIZE
WEIGHT INSTALLATION OPERATION MAKE & MODEL IMAGE SURFACE MATERIAL
BLACK
DROP
CONTROL
REFERENCE
DETAILHEIGHT
(IH)
WIDTH
(IW)
HEIGHT
(CH)
WIDTH
(CW)
DEPTH
(CD)
PST-A 58" 104" 6" 122" 5-1/4" 65 WALL MOUNTED MOTORIZED DRAPER PREMIER (WHITE CASE) XT1000V W/BACKING 40" LVC-III MOTOR CONTROL BOARD / LVC-S LOW VOLTAGE WALL SWITCH 5/AV801
PST-B 79" 140" 7" 158" 9" 104 CEILING RECESSED - FLUSH MOTORIZED DRAPER ACCESS/SERIES E XT1000V W/BACKING 88" LVC-III MOTOR CONTROL BOARD / LVC-S LOW VOLTAGE WALL SWITCH 1/AV800
NOTES:1. SEE ROOM PROJECTION SCREEN SCHEDULE ON THIS SHEET FOR LOCATIONS.2. PROJECTION SCREEN, PROJECTION SCREEN CONTROL SWITCHES, MOUNTING HARDWARE, CONDUITS AND ELECTRICAL WORK BY G.C.3. REFER TO DETAILS LISTED IN THE LEGEND FOR EACH PROJECTION SCREEN TYPE.
FINISHED WALL
THE AREA WITHIN DASHEDLINES INDICATES THE LIGHTPATH FROM PROJECTOR TOSCREEN - SEE NOTE 5.
PROJECTOR POWER, AV ANDNETWORK PULL BOXES (TYP.)SEE NOTE 6.
PROJECTOR SUPPORTASSEMBLY CENTERPOINT
SEE 3/AV800FOR DETAILS
SCREEN POWER & LOW-VOLTAGEJUNCTION BOX (TYP.) - SEE NOTE 7.
PROJECTION SCREEN CASE
FINISHED WALL FINISHED FLOOR FINISHED FLOOR
P LV
J12/P6
SCREEN POWER & LOW-VOLTAGEJUNCTION BOX (TYP.) - SEE NOTE 7.
PROJECTION SCREEN CASE
THE AREA WITHIN DASHEDLINES INDICATES THE LIGHTPATH FROM PROJECTOR TOSCREEN - SEE NOTES 4 & 5.
PROJECTOR SUPPORTASSEMBLY CENTERPOINTSEE 3/AV800 FOR DETAILS
PROJECTOR POWER, AV ANDNETWORK PULL BOXES (TYP.)SEE NOTE 6.
SCREEN POWER & LOW-VOLTAGEJUNCTION BOX (TYP.) - SEE NOTE 7.
LAY-IN OR HARD CEILINGIF CEILING RECESSED.
(BLACK DROP)SEE NOTE 4.
(CH)
(BLACK DROP) SEE NOTE 4.
DISPLAY TYPE LEGEND
ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS
TYPE
IMAGE SIZE CASE SIZE
WEIGHT
DIAGONAL
HEIGHT
(IH)
WIDTH
(IW)
HEIGHT
(CH)
WIDTH
(CW)
DEPTH
(CD)
1 FLAT PANEL TBD TBD TBD TBD TBD TBD TBD
2 SHORT THROWPROJECTOR TBD TBD TBD TBD TBD TBD TBD
NOTES:1. SEE ROOM DISPLAY SCHEDULE ON THIS SHEET FOR LOCATIONS.2. BACKING, JUNCTION BOXES AND CONDUIT PROVIDED BY THE GENERAL CONTRACTOR.
ROOM PROJECTION SCREEN SCHEDULE
ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS
ROOM
NUMBER
SCREEN
TYPE
SCREEN
QTY.
MOUNTING
STYLE
BLACK
DROP
USED
DISTANCE
[D1]
DISTANCE
[D1x]
DISTANCE
[D2]
106 B 1 MS1 88" 180" 18" 198"
129 A 1 MS1 40" 180" 18" NA
VIDEO PROJECTOR MOUNTING STYLE DETAILS
FOR MOUNTING STYLE TYPE MS1 PROJECTOR CEILING MOUNT SEE: DETAIL 3/AV800 AND NOTES BELOW.
PROJECTION SCREEN / VIDEO PROJECTOR RELATIONSHIP (SEE GRAPHIC AND NOTES BELOW)
ROOM DISPLAY SCHEDULE
ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS
ROOM
NUMBER
DISPLAY
TYPE
DISPLAY
QTY.
MOUNTING
STYLE
AFF
100 1 1 FPD1 60"
101 1 2 FPD1 60"
102 1 1 FPD1 52"
130 1 1 FPD1 54"
201 1 1 FPD1 44"
202 1 1 FPD1 44"
209 1 1 FPD1 44"
215 1 1 FPD1 44"
216 1 1 FPD1 44"
217 1 1 FPD1 44"
218 1 1 FPD1 44"
219 2 2 FPD1 102"
FLAT PANEL DISPLAY MOUNTING STYLE DETAILS
FOR MOUNTING STYLE TYPE FPD1 WALL MOUNTED FLAT PANELDISPLAY: SEE DETAIL 1,2/AV801
AUDIOVISUAL NOTES
AND SCHEDULES
R
D
6
6
UP
UP
UP
DN
RISER
1AV600
RISER
2AV600
RISER
1AV601
RISER
3AV600
RISER
5AV600
1
RISER
5AV600
FB1(N1,P1) FB1(N1,P1)
J2 N2P3
J8
J6 J5
N2
P3J3,J9(N3,P4)
J9(N3,P4)
FB1(N1,P1)
J2N2
P3
J5
J9(N3,P4)
J9(N3,P4)
J6J7J7
AV700
1
AV7003
AV700
4
AV700 2
RISER
3AV601
1
J9(N3,P4)
AV701
3
J3N2
P3
RISER
3AV601
1
1
1
1 4 6 7 9 12 15 16141311
H
E
C
K
F.2
D
I
M
H
E
C
L
A
B
F.1
G
J
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
SCALE:AUDIOVISUAL INFRASTRUCTURE FLOOR PLAN - LEVEL 1
1/8"=1'-0"
AV100
AUDIOVISUAL
INFRASTRUCTURE
FLOOR PLAN - LEVEL 1
MECHANICAL
110
CIRCULATION
WORKROOM
114
AUTOMATED
MATERIALS
HANDLING
113
CIRCULATION
SUPERVISOR
115
VESTIBULE
100
MEETING ROOM
106
MTG RM STORAGE
107
VESTIBULE
103
PERIODICALS
105
MANAGER
116
CHILDREN'S
READING AREA
130
MENS
121
WOMENS
120
STAFF BREAK
117
TOILET
124
STORAGE
122
TOILET
119
STAFF VESTIBULE
118
STAFF
126
OFFICE
127
STORAGE
128
CRAFTS
129
CUSTODIAL
123
ELEVATOR
MACHINE RM
111
KITCHENETTE
109
COMMON AREA
101
INTERNET CAFE
102
STAIR
104
STAIR 1
S1
STAIR 2
S2
MTG RM AV / IT
108
6 6
6 6
RISER
2AV601
RISER
4AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
N2
P3
J5
N2
P3J3,J9(N3,P4)
N2P3J3,J9(N3,P4)
N2 P3J3,J9(N3,P4)
N2 P3J3,J9(N3,P4)
N2 P3J3,J9(N3,P4)FB1(N1,P1)
FB1(N1,P1)
J5
N2
P3J2
N2
P3J3,J9(N3,P4)
AV700
5
AV700
6AV701
1
AV701 2
P2J3,J9(N3,P4)
N2
P2J3,J9(N3,P4)
N2
J2FB1(N1,P1)
J9(N3,P4)
J3N2
P3
RISER
3AV600
1
11
1
11
1
2
2
H
E
L
A
B
F.1
G
J
H
E
C
L
A
B
F.1
G
J
H
E
C
L
K
F.2
B
D
I
M
1 4 6 7 9 12 15 16141311 17
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
SCALE:AUDIOVISUAL INFRASTRUCTURE FLOOR PLAN - LEVEL 2
1/8"=1'-0"
AV101
AUDIOVISUAL
INFRASTRUCTURE
FLOOR PLAN - LEVEL 2
CONFERENCE
209
STAFF
203
TEEN STUDY
202
TEEN STUDY
201
TEENS
200
QUIET STUDY
228
ADULT SERVICES
221
CUSTODIAL
208
MENS
205
WOMENS
206
STUDY
215
STUDY
218
STUDY
216
STUDY
217
DIGITAL MEDIA
LAB
219
STAFF TOILET
207
OFFICE
222
STORAGE
224
STORAGE
223
IT OFFICE
225
IT
226
STUDY
213
STUDY
214
COLLABORATION
ZONE
212
STAIR 1
S1
STAIR 2
S2
CIRCULATION
210
VENDING
211
ADULT READING
AREA
220
RISER
1AV600
RISER
2AV600
RISER
1AV601
RISER
3AV600
RISER
5AV600
B
A
RISER
5AV600
PP6
PP6
J12
J12
J10
J14
J14
J14
J14J14
J14
J14
J14
J14 J14
J14J14
J14 J14
N6 J11PP5
J10
N6 J11PP5
AV700
1
AV7003
AV700
4
AV700 2
RISER
3AV601
AV701
3
RISER
3AV601
J10
1 4 6 7 9 12 15 16141311
H
E
C
K
F.2
D
I
M
H
E
C
L
A
B
F.1
G
J
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
SCALE:AUDIOVISUAL INFRASTRUCTURE CEILING PLAN - LEVEL 1
1/8"=1'-0"
AV200
AUDIOVISUAL
INFRASTRUCTURE
CEILING PLAN - LEVEL 1
MECHANICAL
110
CIRCULATION
WORKROOM
114
AUTOMATED
MATERIALS
HANDLING
113
CIRCULATION
SUPERVISOR
115
VESTIBULE
100
MEETING ROOM
106
MTG RM STORAGE
107
VESTIBULE
103
PERIODICALS
105
MANAGER
116
CHILDREN'S
READING AREA
130
MENS
121
WOMENS
120
STAFF BREAK
117
TOILET
124
STORAGE
122
TOILET
119
STAFF VESTIBULE
118
STAFF
126
OFFICE
127
STORAGE
128
CRAFTS
129
CUSTODIAL
123
ELEVATOR
MACHINE RM
111
KITCHENETTE
109
COMMON AREA
101
INTERNET CAFE
102
STAIR
104
STAIR 1
S1
STAIR 2
S2
MTG RM AV / IT
108
RISER
2AV601
RISER
4AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
RISER
2AV600
J14 J14
J14J14
J14
J14
J14
J14
J14
J14
J10
AV700
5
AV700
6AV701
1
AV701 2
RISER
3AV600
J10
H
E
L
A
B
F.1
G
J
H
E
C
L
A
B
F.1
G
J
H
E
C
L
K
F.2
B
D
I
M
1 4 6 7 9 12 15 16141311 17
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
SCALE:AUDIOVISUAL INFRASTRUCTURE CEILING PLAN - LEVEL 2
1/8"=1'-0"
AV201
AUDIOVISUAL
INFRASTRUCTURE
CEILING PLAN - LEVEL 2
CONFERENCE
209
STAFF
203
TEEN STUDY
202
TEEN STUDY
201
TEENS
200
QUIET STUDY
228
ADULT SERVICES
221
CUSTODIAL
208
MENS
205
WOMENS
206
STUDY
215
STUDY
218
STUDY
216
STUDY
217
DIGITAL MEDIA
LAB
219
STAFF TOILET
207
OFFICE
222
STORAGE
224
STORAGE
223
IT OFFICE
225
IT
226
STUDY
213
STUDY
214
COLLABORATION
ZONE
212
STAIR 1
S1
STAIR 2
S2
CIRCULATION
210
VENDING
211
ADULT READING
AREA
220
FINISHEDCEILING
FLOOR / GRADE
FINISHEDCEILING
FLOOR / GRADE
(1) 1" C
J3
A
A N WALL MOUNTEDFLAT PANEL DISPLAY
J9(N3,P4)
P3 N2
N
FINISHEDCEILING
FLOOR / GRADE
FINISHEDCEILING
FLOOR / GRADE
(1) 1" C
A N WALL MOUNTEDFLAT PANEL DISPLAY
J9(N3,P4)
ADULT SERVICES 221
P3
FINISHEDCEILING
FLOOR / GRADE
FINISHEDCEILING
FLOOR / GRADEFB1(N1,P1)
A N1
A
(3) 2" C
(1) 1" C(1) 1-1/4"C
(1) 1-1/4"C
(1) 1" C
J2
A
N2
N
J10
A
J5
CONTROL PANEL
A
J14A
J14A
(1) 3/4" C
SEE PLANSFOR QUANTITY
(1) 3/4" C
FINISHEDCEILING
FLOOR / GRADE
FINISHEDCEILING
FLOOR / GRADE
(1) 1" C
A N WALL MOUNTEDFLAT PANEL DISPLAY
J9(N3,P4)
P3
FINISHEDCEILING
FLOOR / GRADE FLOOR / GRADE
FB1(N1,P1)(TYP. FOR 1 OF 2)
A N1
A
(3) 2" C
(1) 1" C(1) 1-1/4"C
(1) 1-1/4"C
(1) 1-1/4"C(1) 1" C
(1) 3/4" C
J6SCREENSWITCHA
MJ12
PROJECTIONSCREEN A P
P6
J2
A
N2
N
J10
A
J11A P
P5 N6
N
J5
CONTROL PANEL
A
J14A
J14A
(1) 3/4" C
(1) 1" C
J8
CAMERA
A
SEE PLANSFOR QUANTITY
(1) 3/4" C
(1) 3/4" C
FINISHEDCEILING
MTG RM AV / IT 108MEETING ROOM 106
(1) 1-1/4" C
NAA
J9(N3,P4)SHORT THROW
PROJECTOR*COORDINATE WITH
ARCHITECTURALS
(1) 1-1/4" C
J3
A
N2
NP2
(TYP. FOR 1 OF 2)
TO ADULT SERVICES221 (J10)
J3
AP3N2
N
42"
J10
A
(2) 1-1/4" C
FROM COMMONAREA 101
(1) 1" C
VESTIBULE 100
COMMON AREA 101
VIDEO PROJECTOR
(TYP. FOR 1 OF 2)
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV600
AUDIOVISUAL ROOM
RISER DIAGRAMS
POWER DESIGNATORS & NETWORK JUNCTION BOXESON AUDIOVISUAL RISERS
POWER DESIGNATORS AND RECEPTACLESPOWER DESIGNATORS AND RECEPTACLES WHICH APPEAR ONTHE AUDIOVISUAL RISERS ARE SHOWN TO INDICATE THEIRREQUIRED ADJACENCY TO AUDIOVISUAL COMPONENTS. SEE THE"AUDIOVISUAL SYMBOLS AND LEGENDS" SHEET FOR ADDITIONALINFORMATION ON POWER RECEPTACLES FOR TECHNOLOGYSYSTEMS. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETEPOWER LAYOUTS AND CIRCUITING DETAILS.
NETWORK OUTLETS FOR AUDIOVISUAL SYSTEMSNETWORK OUTLETS SHOWN ON THE DRAWINGS REPRESENTNETWORK CONNECTIVITY IN SUPPORT OF AUDIOVISUAL SYSTEMSAND TO INDICATE THEIR REQUIRED ADJACENCY TO AUDIOVISUALCOMPONENTS.
REFER TO THE STRUCTURED CABLING SYSTEMS DRAWINGS ANDSPECIFICATIONS FOR ADDITIONAL INFORMATION.
CONDUIT MUST BE PROVIDED FOR ALL NETWORK OUTLETSSERVING AUDIOVISUAL SYSTEMS.
RISER SYMBOLS LEGEND
JUNCTION BOX FOR NETWORK OUTLETS
FLEXIBLE CONDUIT
CONDUIT STUB
JUNCTION BOX FOR AUDIOVISUAL
P
A
N
POWER DESIGNATORS
A N AN AUDIOVISUAL DEVICE WHICH CONTAINS APOWER RECEPTACLE AND A NETWORK OUTLET
SCALE:1
AV600MEETING ROOM 106 AND MTG RM AV / IT 108
NTS
SCALE:2
AV600TYPICAL GROUP STUDY
NTS
SCALE:5
AV600TYPICAL DIGITAL SIGNAGE
NTSSCALE:4
AV600DIGITAL MEDIA LAB 219
NTSSCALE:3
AV600DIGITAL SIGNAGE
NTS
P3
FINISHEDCEILING
FLOOR / GRADE FLOOR / GRADE
(3) 2" C
(1) 1-1/4"C(1) 1" C
(1) 3/4" C
J6SCREENSWITCHA
MJ12
PROJECTIONSCREEN A P
P6
J2
A
N2
N
J10
A
J11A P
P5 N6
N
J5
CONTROL PANEL
A
J14A
J14A
(1) 3/4" CSEE PLANSFOR QUANTITY
(1) 3/4" C(1) 3/4" C
FINISHEDCEILING
CRAFTS 129(TYP. FOR 1 OF 2)
(1) 3/4" C
J7
PROGRAMLOUDSPEAKERS
A
P3
FINISHEDCEILING
FLOOR / GRADE FLOOR / GRADE
J2
A
N2
N
J5
CONTROL PANEL
A
J14A
J14A
(1) 3/4" CSEE PLANSFOR QUANTITY
(1) 3/4" C
FINISHEDCEILING
CONFERENCE 209
A N WALL MOUNTEDFLAT PANEL DISPLAY
J9(N3,P4)
FB1(N1,P1)
A N1
A
(1) 1" C(1) 1-1/4"C
(1) 1-1/4"C
(1) 1-1/4"C(1) 1"C
FINISHEDCEILING
FLOOR / GRADE
FINISHEDCEILING
FLOOR / GRADE
(1) 1" C
A N WALL MOUNTEDFLAT PANEL DISPLAY
J9(N3,P4)
STAFF 126
J3
AP3N2
N
42"
J10
A
(1) 1-1/4" C
CHILDREN'S READING AREA 130
VIDEO PROJECTOR
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV601
FLEXIBLE CONDUIT
CONDUIT STUB
JUNCTION BOX FOR AUDIOVISUAL
P
A
N
POWER DESIGNATORS
A N
AUDIOVISUAL ROOM
RISER DIAGRAMS
SCALE:1
AV601CRAFTS 129
NTS
SCALE:2
AV601CONFERENCE 209
NTS
POWER DESIGNATORS & NETWORK JUNCTION BOXESON AUDIOVISUAL RISERS
POWER DESIGNATORS AND RECEPTACLESPOWER DESIGNATORS AND RECEPTACLES WHICH APPEAR ONTHE AUDIOVISUAL RISERS ARE SHOWN TO INDICATE THEIRREQUIRED ADJACENCY TO AUDIOVISUAL COMPONENTS. SEE THE"AUDIOVISUAL SYMBOLS AND LEGENDS" SHEET FOR ADDITIONALINFORMATION ON POWER RECEPTACLES FOR TECHNOLOGYSYSTEMS. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETEPOWER LAYOUTS AND CIRCUITING DETAILS.
NETWORK OUTLETS FOR AUDIOVISUAL SYSTEMSNETWORK OUTLETS SHOWN ON THE DRAWINGS REPRESENTNETWORK CONNECTIVITY IN SUPPORT OF AUDIOVISUAL SYSTEMSAND TO INDICATE THEIR REQUIRED ADJACENCY TO AUDIOVISUALCOMPONENTS.
REFER TO THE STRUCTURED CABLING SYSTEMS DRAWINGS ANDSPECIFICATIONS FOR ADDITIONAL INFORMATION.
CONDUIT MUST BE PROVIDED FOR ALL NETWORK OUTLETSSERVING AUDIOVISUAL SYSTEMS.SCALE:
3AV601
CHILDREN'S READING AREA 130 DIGITAL SIGNAGENTS
TYPE-B
EQ EQ
88"
48"
SCRE
ENCE
NTER
LINE
J9(N3,P4)
BACKING MATERIAL60"
30"
EQ EQ
2AV801
60"
DISP
LAY
CENT
ERLIN
E
J9(N3,P4)BACKING MATERIAL 60"
30"
N2 J3 P3
18"
EQEQ
52"
2AV801
DISP
LAY
CENT
ERLIN
E
J9(N3,P4)
44" TOCENTER OF
J-BOX
BACKING MATERIAL
VIDEO DISPLAYMOUNT (NIC)
VIDEO DISPLAY(NIC)
60"
30"
N2 J3 P3
18"
2AV801
72" 84 3/4"
DISP
LAY
CENT
ERLIN
E
J9(N3,P4)
44" TOCENTER OF
J-BOX
BACKING MATERIAL 60"
30"
2AV801
DISP
LAY
CENT
ERLIN
E
EQ EQ
TYPE-A
EQ EQ
J5 J6
J7 J7
102"
48"
72" 72"
50 3/4"
40"
144"
SCRE
ENCE
NTER
LINE
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV700
AUDIOVISUAL ELEVATIONS
SCALE:1
AV700MEETING ROOM 106 - NORTH WALL ELEVATION
3/8" = 1'-0" SCALE:2
AV700VESTIBULE 100 - EAST WALL ELEVATION
3/8" = 1'-0" SCALE:3
AV700INTERNET CAFE 102 - WEST WALL ELEVATION
3/8" = 1'-0"
SCALE:4
AV700CRAFTS 129 - SOUTH WALL ELEVATION
3/8" = 1'-0" SCALE:5
AV700CONFERENCE 209 - NORTH WALL ELEVATION
3/8" = 1'-0" SCALE:6
AV700STUDY 215 - SOUTH WALL ELEVATION
3/8" = 1'-0"
102" TOCENTER OF
J-BOX
60"
30"
N2 J3 P2
18"
J9(N3,P4)BACKING MATERIAL
DISP
LAY
CENT
ERLIN
E
102" TOCENTER OF
J-BOX
60"
30"
N2 J3 P2
18"
J9(N3,P4)BACKING MATERIAL
DISP
LAY
CENT
ERLIN
E
J9(N3,P4)
54"
60"
30"
EQEQ
DISP
LAY
CENT
ERLIN
E
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV701
AUDIOVISUAL ELEVATIONS
SCALE:1
AV701DIGITAL MEDIA LAB 219 - NORTH-NORTHEAST WALL ELEVATION
3/8" = 1'-0" SCALE:2
AV701DIGITAL MEDIA LAB 219 - EAST WALL ELEVATION
3/8" = 1'-0" SCALE:3
AV701CHILDREN'S READING AREA 130
3/8" = 1'-0"
METHOD FOR INSTALLING CEILINGMOUNTED VIDEO PROJECTOR TOUNDERSIDE OF DECK (TYP)
SIDE ELEVATION
NOTES:
1. SEE DETAIL 13/A210 FOR DIMENSION AND PLACEMENT.
FINISHED CEILING
[J11], [N6] & [P5] MOUNT AT REAR OF CUBBYPER NEC REQ.
PROJECTOR CUBBY
9"
6 9/16"7"
11/16"
2 1/8" SLOT 1"
CASE WIDTH (CW)
7-1/2" TO 8"
MOUNTING DETAILS
MOUNTING WITHSUSPENDED CEILING
MOUNTING WITHDRYWALL CEILING
8" TRIM FLANGE
SUSPENDED CEILINGBY OTHERS
3/8 DIA. THREADED RODBY OTHERS
DRYWALL CEILINGBY OTHERS
3/8 DIA. LAG BOLTSINTO BLOCKING BY OTHERS
VIEWING SURFACESEE SHEET AV002 FOR SIZE
7/8" ELEC CONNECTION HOLEON TOP OF LEFT END OF CASE.
ISOMETRIC
8" TRIM FLANGE
8" TRIM FLANGE
WOOD OR METAL STUDS
16"W x 18"H x 3/4"THKPLYWOOD BACKING
[J7] J-BOX
1. BACKING (FOR LOUDSPEAKERS PROVIDED BY OTHERS)
2. SEE PARTITION TYPES FOR STUD SIZE & GAUGE
3. VERIFY LOCATIONS OF BACKING PLATES WITH TECHNOLOGY DRAWINGS
4. FASTEN 3/4" PLYWOOD FLUSH WITH FACE OF STUDS
5. SPAN BETWEEN TWO STUDS
1" OR 1-1/4"AUDIOVISUAL
ISOMETRIC VIEW
3/4" OR 1"TELECOM
14 3/4"
12 5/8"
4 1/8"
POWER1" OR 1-1/4"
AV OR TELECOMISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV800
SCALE:3
AV800TYPICAL PROJECTOR MOUNT
NTS
SCALE:1
AV800TYPICAL PROJECTOR SCREEN
NTS SCALE:2
AV800TYPICAL LOUDSPEAKER SUPPORT
NTS
AUDIOVISUAL
DETAILS
SCALE:4
AV800LEGRAND/WIREMOLD RFB9 FLOOR BOX
NTS
[J9] ASSEMBLYPWB-100(BY FSR) STUD
(2) STUD BRACKET (2 - #6-32 x 1/4"PAN HEAD SCREWS)
COVER (4 PAINTED#6-32 x 3/4" OVAL
HEAD SCREWS)
1/2" - 5/8" WALLTHICKNESS
NEW WORK INSTALLATIONWALL OPENING: 11" x 5-1/4"
UPPER LOW-VOLTAGE ENTRY BOX NO.1FOR AUDIOVISUAL CONNECTIONS
SHIPPED STANDARD WITH ASSEMBLY(2 - #6-32 x 1/4" PAN HEAD SCREWS)
STUD MOUNTINGHARDWARE BY
G.C.(#6 SCREW,
1/2"x1" STAPLE,OR NAIL)
16" STUD CENTERS
MOUNTING HOLESFOR 1/2" DRYWALL MOUNTING HOLES
FOR 5/8" DRYWALLDIRECT-TO-STUDMOUNTING HOLES
[P4] AC OUTLET BOX(4 - #6-32 x 1/4"PAN HEAD SCREWS)
LOWER LOW-VOLTAGE ENTRY BOX NO.2FSR PART NO. PWB-100-CBB
FOR AUDIOVISUAL CONNECTIONS - NOT SHOWN(MUST BE ORDERED SEPARATELY)
COVER CENTER SECTION (2 - #6-32 x 1/2"UNDERCUT FLAT HEAD SCREWS)
[N3] NETWORK OUTLET BOXNOT SHOWN
(MUST BE ORDERED SEPARATELY)
1. BACKING AND J-BOX FOR WALL MOUNTED FLAT PANEL DISPLAY2. BACKING MUST BE MIN 32"W AND 24"H WITH J-BOX CENTERED AT LOCATION3. ALWAYS SPAN BETWEEN THREE STUDS.4. SEE PARTITION TYPES FOR STUD SIZE AND GAUGE.5. VERIFY LOCATIONS OF BACKING PLATES WITH PLANS & ROOM ELEVATIONS.6. FASTEN PLYWOOD OR METAL BACKING FLUSH WITH FACE OF STUDS.7. FLAT PANEL DISPLAYS AND MOUNTING BRACKETS BY AV CONTRACTOR.
WOOD OR METAL STUDS
3/4" PLYWOOD OR 16 GAUGE STEEL BACKING SECTIONS
SPAN AT LEAST 3 STUDS
AV COMPARTMENTTOP AND/OR BOTTOM
POWER RECEPTACLE &NETWORK OUTLET
FSR PWB-100 ASSY.
FSR PWB-100[J9] ASSEMBLY
CUTOUT ANDFSR ASSEMBLY
BY E.C.
STUDS ANDPLYWOOD BACKINGBY G.C.
CASE WIDTH (CW)
VIEWING SURFACESEE SHEET AV002 FOR SIZE
1/4" TO WALL MOUNTING HOLE1 13/16"
5 1/4"
5 7/8"
CEILING MOUNTHOLE
7/8" ELECTRICALCONNECTION HOLE
WALLMOUNTING
MOUNTING DETAILS
ISOMETRIC
S-HOOK FOR SUSPENDEDINSTALLATION BY OTHERS
FASTENERS FOR WALLMOUNTING BY OTHERS
ISSUE DATE:
DRAWN BY:
PROJECT MANAGER:
REVISIONS:
PROJECT NUMBER:
KEY PLAN:
GENERAL NOTE:
SHEET TITLE:
SHEET NUMBER:
PA
TH
&
F
IL
EN
AM
E:
PLO
TT
IN
G D
AT
E &
T
IM
E:
Material included herein is covered by copyright. Use of this work in whole or in
part is forbidden without the expressed written consent of BCWH, Inc and the
County of Henrico.
1840 West Broad Street
Suite 400
Richmond, Virginia 23220
www.bcwh.com
804.788.4774 phone
804.788.0986 fax
Tappe Associates, Inc
Six Edgerly Place
Boston, MA 02116
www.tappe.com
tel 617.451.0200
fax 617.451.3899
DEPARTMENT OF
GENERAL SERVICES
C:\U
sers\e
ho
gan
\D
ocu
me
nts\_R
evit\A
RC
H-121
0-C
D-R
13_
eh
oga
n.rvt
2/10/2014
4
:4
5:1
9 P
M
05/04/2014
SF
JT
100% CONSTRUCTION
DOCUMENTS
1210.00
LIBBIE MILL
LIBRARY
COUNTY OF HENRICO
LIBBIE MILL
AV801
SCALE:1
AV801FSR PWB-100 FLAT PANEL BACK BOX
NTS SCALE:2
AV801TYPICAL FLAT PANEL SUPPORT STRUCTURE
NTS
AUDIOVISUAL
DETAILS
SCALE:3
AV801DROP CEILIING MOUNTED LOUDSPEAKER DETAIL
NTS
SCALE:4
AV801NOT USED
NTS
SCALE:5
AV801WALL MOUNT PROJECTION SCREEN DETAIL
NTS