AutoLog® GSM RTU for cathodic protection

10
FF-AUTOMATION Copyright ® FF-Automation Oy, 2011 AutoLog® GSM RTU for cathodic protection

Transcript of AutoLog® GSM RTU for cathodic protection

Page 1: AutoLog® GSM RTU for cathodic protection

FF-AUTOMATION

Copyright ® FF-Automation Oy, 2011

AutoLog® GSM RTU for cathodic protection

Page 2: AutoLog® GSM RTU for cathodic protection

AutoLog® ControlMan

AutoLog® SCADA AutoLog® PLC

AutoLog® HMI

AutoLog® OEM AutoLog® Radio Modem

AutoLog® Wireless

AutoLog® TETRA

AutoLog® GSM

AutoLog® Products

AutoLog® RTU

FF-Automation Oy

Page 3: AutoLog® GSM RTU for cathodic protection

Oilwells and pumps

Cathodic protection Street light control

Tanks & storages Pump control

Water treatment

Pipelines & valves

Real estate objects

Production facilities

AutoLog® Applications

FF-Automation Oy

Page 4: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy AutoLog® CP monitoring

Cathodic protection scheme

Cathodic protection rectifier,

powered from solar panel is

applying potentials to the

electrodes and gets current and

voltage measurements.

AutoLog® GSM RTU conneced

to the rectifier will bring those

measurements to GSM network

and Inernet.

Measurements may be taken by

simple sensors with for example

4..20 mA, 0..+5 VDC output

signal or with ModBus sensors

directly connected to GSM PLC.

Using SMS or GPRS connection

measurement results may be

forwarded directly to mobile

phone, e-mail or higher level of

data acquisition like SCADA or

ControlMan.

Solar panels

with backup

batteries

Pipeline

Outdoor GSM

Antenna

AutoLog®

GSM RTU

Cathodic

protection

electrodes

Cathodic

protection

rectifier Connection

cable (RS232,

RS485 etc.)

Example installation view

Page 5: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy

AutoLog® integrated GSM RTU

AutoLog® GSM PLC

Incoming

measurements

Outgoing

controls

Sensors,

Switches,

etc.

Cathodic

Protection

Rectifier

Board

GSM Gateway PLC is able to

poll ModBus devices, send

data through GSM / GPRS

network and process

measurements according its

internal application

program.

AutoLog®

RTU

ModBus

RTU

(RS232/

RS485)

AutoLog® may be integrated inside

existing Cathodic Portection rectifiers,

can read measurements and apply

controls.

Pipeline

Page 6: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy AutoLog® CP monitoring

AutoLog® ControlMan Cathodic protection

Cathodic

Protection

rectifier

AutoLog® GSM RTU

Computer with Internet

access and web-browser

ControlMan

secured Internet

server

GSM / GPRS

network

Internet /

Intranet

network

Example installation view

Page 7: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy AutoLog® CP monitoring

AutoLog® ControlMan

Internet-based ControlMan software provide

access to dynamic maps, trends, graphs,

process illustrations, alarm views from any

computer with Internet access.

Alarms may be

forwarded

directly to

dedicated mobile

phone or e-mail.

Page 8: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy

AutoLog® GSM-GATEWAY PLC Specifications

AutoLog® GSM PLC

AutoLog® Modbus-GSM Gateway read/writes

data from Field device(s) using Modbus RTU

protocol. This data can be logged into Modbus-

GSM Gateway’s memory.

AutoLog® Modbus-GSM Gateway uses

GSM/GPRS network for bidirectional

communication with SCADA systems. FF-

Automation’s AutoLog ControlMan SCADA can

be used to view measurement trends, alarms,

process pictures, reports etc. and to send

controls, set points etc. Alarms can be forwarded

to GSM phones.

AutoLog® Modbus-GSM Gateway is a

programmable device as all AutoLog GSM-RTUs.

It can make intelligent Clock/Calendar or events

based controls, calculations etc. It is remotely

programmable.

Storage

temperature -40 .. +80 °C

Operating

temperature -30°C…+65°C

Relative

humidity 95%, non-condensing

Enclosure IP20 / optional IP65 etc.

Dimensions 170 x 170 x 80 mm (W x H x D)

Weight About 0.2 kg

Mounting DIN rail

AutoLog® Modbus-GSM Gateway connects

Modbus devices to GSM network. It has all

the same features as other AutoLog GSM-

RTU devices, but without I/O. It can be used

also to read / write data with AutoLog

Wireless Wi-Fi Sensors and send this data to

GSM / Modbus / Ethernet network.

Serial Port 1 For Integrated GSM/GPRS modem

Serial Port 2

(default) Modbus RTU master/slave

(RS232),

Optional 1: (RS485)

Optional 2:Modbus TCP (ETH)

masster/slave

Optional 3: Wireless Sensor Master

Module (ALWSN24-PiM-MM)

GSM communication

SMS and GPRS / FTP

I2C port 1 (HMI, etc.)

Communication SMS, GPRS, Modbus RTU M/S, Modbus

TCP M/S, Wireless Sensor

Page 9: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy

Iran

FF-Automation has a worldwide network of AutoLog system

integrators and distributors. We are also constantly seeking more new

co-operation partners, representatives and software partners.

Korea

India

Pakistan

Philippines

Iran

China

Indonesia

Singapore

North America

Brazil

England

Sweden

Latvia

South Africa

Finland Russia

Ukraine

Malaysia

Thailand

Saudi-Arabia

U.A.E

AutoLog® Connections

Page 10: AutoLog® GSM RTU for cathodic protection

FF-Automation Oy

.

FF-AUTOMATION OY

Head Office:

Eräkuja 2, 01600 Vantaa,

Finland

tel: +358 10 2190 500

fax: +358 3 5846 711 e-mail: [email protected]

Factory:

Valkeakoski, Finland

For more information

about FF-Automation

and the AutoLog® range

of control products and

automation solutions,

please open

www.ff-automation.com

Contact information