Aurora Clean Room Pack
-
Upload
thien-nguyen-xuan -
Category
Documents
-
view
218 -
download
0
Transcript of Aurora Clean Room Pack
8/4/2019 Aurora Clean Room Pack
http://slidepdf.com/reader/full/aurora-clean-room-pack 1/4
ICP-MS
For the aurora M90 ICP-MS
Clean Room Pack
Innovation with Integrity
8/4/2019 Aurora Clean Room Pack
http://slidepdf.com/reader/full/aurora-clean-room-pack 2/4
Benefts include
Maintain integrity of highly sensitive
clean room environment. All vacuum
pumps are housed inside the instrument,
and air from the pumps and instrument
is extracted out of the clean room. Save
valuable laboratory space. All pumps are
contained within the body of the ICP-MS,
resulting in the smallest footprint of any
commercially available ICP-MS system.
Backed by the most sensitive ICP-MS
units available, featuring:
Unique collisional interface/extraction
optics [1] that minimize interferences,
providing reliable, routine, trace level
quantification.
Optimized sample introduction system,
including computer-controlled Peltier-
cooled spraychamber, that reduces
interferences and improves stability.
As semiconductor devices shrink and contamination tolerances are reduced, quality control
of chemicals by ICP-MS becomes even more crucial. The Clean Room Pack for the Bruker
aurora M90 ICP-MS helps maintain the contamination-free environment required. Combined
with the industry-leading sensitivity of the Bruker ICP-MS, this fully contained system enables
you to achieve the lowest possible detection limits in highly sensitive environments.
Clean Room Pack
Robust, high-efficiency plasma system
and patented Turner Interlaced Coils
[2] that break down the toughest
sample matrices, reduce matrix
effects, and minimize ion energy
spread for maximum sensitivity and
stability.
Patented 90 degree ion mirror [3] and
low noise double off-axis quadrupolethat provide industry leading sensitivity
and background.
Unique collision/reaction interface
(CRI) [4] system provides simple,
routine removal of troublesom
spectroscopic interferences.
8/4/2019 Aurora Clean Room Pack
http://slidepdf.com/reader/full/aurora-clean-room-pack 3/4
Clean Room Pack
Related accessories:
The Bruker nitrox 500 boosts the analyti-
cal performance for the aurora M90,
Adds oxygen to the plasma to
eliminate carbon deposition on the
injector tube and sampler cone when
analyzing organic solvents.
Adds nitrogen to the plasma for better
detection of elements with high ioniza-
tion potential (eg. As, Se).
The clean room pack contains an o-ring
free inert sample introduction system
consisting of:
Inert Perfluoro Acetate (PFA), double
pass spraychamber that is Peltier
cooled to achieve the lowest
interferences, such as those from
oxide ions. Allows the analysis of
aggressive samples and acids,
including hydrofluoric acid (HF).
Low flow, inert PFA nebulizer thatis safe for use with HF. To allow the
nebulizer to be set at optimal
nebulization conditions, an inert sheath
gas transfer line is also included.
Semi-demountable torch with a high-
purity inert platinum injector tube that
reduces contamination from the
injector.
Pair of platinum-tipped interface cones
that increase cone lifetime for
aggressive samples and acids.
[1] (US patent 7,119,330 B2);
[2] (US patent 5,194,731);
[3] (US patent 6,614,021 B2);
[4] (US patent 7,329,863 B2)
Description Part
number
Clean Room Kit for the Bruker
aurora M909920000600
8/4/2019 Aurora Clean Room Pack
http://slidepdf.com/reader/full/aurora-clean-room-pack 4/4
B
k
D
l t
i
i
t i
l l
i
i
i t
d
t
d
t h
i h t
Chemical Analysis Solutions
Laboratory gas chromatography systems
The 400 Series consists of two gas chromatographs and an
associated range of analyzers and solutions designed for leading
applications. These systems allow chemists and engineers to employ
standard methods and/or high quality trace sample analysis, in the
petrochemical, agrochemical and environmental industries.
The 450-GC is a highly affordable and powerful analytical instrument
that offers robust operation in an easy-to-use package. The system
gives users a broad choice of injectors, detectors, switching and
sampling valves up to three channels. The high resolution color touch
screen is intuitive and supports local languages. The Bruker 430-GCoffers the same outstanding performance as the 450-GC but in a
compact, single channel package that occupies about half the bench
space of conventional multi-channel GC.
Triple quadrupole mass spectrometer
The Bruker 320-MS GC/MS stands at the forefront of configurable
triple-quadrupole mass spectrometer systems. It offers: femtogram
sensitivity, 10 – 2000 Da mass range, and a wide array of
chromatographic and ionization configurations to uniquely
match your needs - all in less than 72 cm. (28 in.) of linear
bench space! In minutes, the 320-MS can be changed
from EI to CI modes of operation. Easily,the 320-MS is the most sensitive,
robust, and flexible triple-quadrupole
MS system currently available.
For research use only.
Not for use in diagnostic procedures.
Bruker Daltonik GmbH
Bremen · Germany
Phone +49 (421) 2205-0
Fax +49 (421) 2205-103
Bruker Daltonics Inc.
Billerica, MA · USA
Phone +1 (978) 663-3660
Fax +1 (978) 667-5993
www.bruker.com/chemicalanalysis