Page 2: Auraton_2005

I0

AURATON 2005

AURATON 2005 TX Plus

Communication code of AURATON 2005 TX Plus can be manually set by user. The factory set communication code is "085". If there are troubles with communication between AURATON 2005 TX Plus and RX Plus the code can be changed (Manual, page 41).

AURATON 2005 RX Plus

29 EN

Page 3: Auraton_2005

1. Installation instructionsAURATON 2005

Caution: Switch off the electric source before installing the thermostat. We recommend that the installation should be performed by a trained personnel.

1.1 Select a suitable location for the AURATON

2005.

The location of the thermostat can greatly affect its performance. If it is located at where circulate air cannot reach, or exposed to direct sun light, it will not adjust the room temperature properly.

To ensure proper operation, the thermostat should be installed at an inside wall with freely circulating air. Find a place where your family usually occupied.

.

Avoid close to some heat generating appliance (e.g. TV, heater, refrigerator) or exposed to direct sun light. Do not install near a door where the thermostat will suffer from vibration.

15

0cm

właściwe usytuowanie sterownikaPROPERLY INSTALLED THERMOSTAT AURATON 2005

AURATON 2005 - Installation 30EN

Page 4: Auraton_2005

1.2 Wiring AURATON 2005

Wiring terminals are at the back of the thermostat. Press down the terminal cover, you can find three terminals which labelled COM, NO and NC. It is a typical single-pole, double throw (SPDT) contact. In most COM and NO are used.

1.3 Mounting the thermostat AURATON 2005

Use the template provided, drill two Ø6mm holes on the wall. Insert the wall anchors and tighten the left screw with 3mm clearance.

NO

COMNC

NO

COM

NC

Fix the thermostat by putting it over the screwhead and slide it rightward (note the keyhole like opening at the back of the thermostat). Tighten the remain screw to lock it in place.

Note:If the wall is made of wood, there is no need to use the wall anchors. Drill two Ø2.7mm holes instead of Ø6mm.

AURATON 2005 - Installation31 EN

Page 5: Auraton_2005

2. Familiar with your AURATON 2005 AURATON 2005 TX Plus

2.1 Appearance

There is a sliding front cover at the right of the thermostat. If you open the cover, you can see some buttons. This cover is removable for the replacement of batteries. To rise up the sliding cover, you can see the dip switch.

PROG0 6 12 18 24

0cd n m

Temp.

Prog.

Prog.#

OK Reset

-

-

+

+

ON

1 2 3

AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON 32

2.2 Temperature mode

You can see "A" and "B" on both the buttons

and the LCD. "A" indicates comfort temperature

and "B" indicates economy temperature. These two temperatures are user changeable. Furthermore,

Othere is a fixed defrost temperature (7 C) indicated

by "d" on the LCD. Throughout the operation of the thermostat we will refer them as comfort, economy or defrost temperature instead of numeric values.

2.3 Dip switches

ON

1 2 3

DELAY 5 MIN.

COOLING

HEATING

NO DELAY

OSPAN TEMP = 1 C

SPAN TEMP O

= 0,5 C

EN

Page 6: Auraton_2005

If you remove the front cover, you can find three small switches (dip switches). These three switches are used to control the span, output-on delay and

Oheat/cool system. Span is the temperature (1 C or O0,5 C) difference between the turn on temperature

and turn off temperature.

2.4 Program

AURATON 2005 or AURATON 2005 TX Plus is a programmable thermostat. It can automatically adjust the room temperature to a comfortable level when you are at home, and lower it to save energy when you go out or sleep. What you have to do is to program the thermostat so that it knows when to raise the temperature. There are altogether nine programs contained in the memory of the thermostat. Six of them are preset in the factory and the remaining three are user changeable.

2.5 LCD

1 - Day of the week Indicator2 - Time3 - Temperature4 - Program Number5 - Program Profile Indicator6 - Manual Override Indicator 7 - Output-On Indicator and temperature Mode

Indicator8 - Low Battery Indicator

0c

PROG0 6 12 18 24

1

2

8

5

4

67

3

AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON33 EN

Page 7: Auraton_2005

Note:

A. The output-on indicator will be displayed if the output is on. It will disappear if the output is off.

B. The low battery indicator will be displayed if the voltage of the batteries drop to a certain level. Please change the batteries as soon as possible.

2.6 Start

The thermostat is operated by two LR6 alkaline batteries. Please remove the front cover and install two new batteries. When the batteries are installed, the thermostat should be operating and you can see the LCD active. If the thermostat does not work properly, please check the batteries for wrong polarities and press the reset button by a ball-point pen.

The LCD after start or reset.

Note:OA. Temperature may not be 22.25 C as the

diagram shown and the Output-On indicator may active after a few seconds, depend on different situations.

B. Do not use a pencil to push the reset button. The graphite residue of a pencil can cause short circuit and damage the thermostat.

34AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON

0c

PROG0 6 12 18 24

. .

EN

Page 8: Auraton_2005

2.7 Set day/time

To set day, press "d" button. Similarly, press "h" button to set hour and "m" button to set minute.

Example: When start or after reset, the time is 00:00, Sunday. To set the clock to current time (e.g., 11:23, Tuesday), press "d" 2 times, "h" 11 times and "m" 23 times.

Note: When you press and hold the keys for 2 seconds the day/time will change rapidly. Release when the desired setting comes.

2.8 View/Change temperature

Press Temp, the thermostat enter View/Change temperature mode. The LCD will show the setting of

the current temperature mode ( A, B or d ) which

will be flashing. Press button "A" or "B" button to review or change the temperature. Press OK will directly return to normal operation mode.

Note:OA. The temperature setting range is 5 to 30 C.

B. To lower the setting, enter View/Change

temperature mode and press "A" or "B" until it Oreaches 30 C and then the setting will return to

O5 C. Continue to press until the desired setting comes.

C. Press and hold the keys, the setting will change rapidly.

D. Please note the temperature mode indicator. A

"A" means the comfort temperature is being viewed or changed.

A "B" indicates economy temperature. If "d" is shown, it is defrost temperature. Defrost

Otemperature is always at 7 C and is not changeable.

E. It is not always necessary to use OK key to return to normal operation mode. After 15 seconds of no key pressed it will automatically return to normal mode.

AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON35 EN

Page 9: Auraton_2005

2.9 View/Change programs

Press "Prog" button, the program of the current day is ready to be changed. Press "Prog" button again can advance to the next day and the program of that day will be shown.Press "Prog#" button to change the program. Programs 6, 7 and 8 are user-define programs. You

can use "A" or "B" to change the distribution of comfort or economy temperature and h to review the setting. Press OK can return to normal operation mode.

There are altogether nine programs available, as the diagram shown: Program 0 is a special program. It will set the whole

Oday to defrost temperature (7 C). (If cooling mode is selected, it will turn off the system). Programs 1,2, and 3 are some typical schedule of a day. You can select them if you found them suitable. Program 4 set the whole day to comfort temperature while program 5 set it to economy. Programs 6, 7 and 8 are user-define programs. They can be modified to suit your need.

36

0 6 12 18 24

0 6 12 18 24

0 6 12 18 24

PROG

PROG

PROG

AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON

0 6 12 18 24

0 6 12 18 24

0 6 12 18 24

0 6 12 18 24

0 6 12 18 24

PROG

PROG

PROG

PROG

PROG

PROG0 6 12 18 24

EN

Page 10: Auraton_2005

Example:

A. Assume you want to assign program 6 to Saturday and want to set the whole day to economy temperature except 13:00 to 18:00. Press "Prog". The thermostat enters program mode and the program of the current day (e.g., Tuesday) is ready to be programmed. The display shows the program for Tuesday is program 1, the temperature for 00:00 is

Oeconomy temperature and is 15 C. (The flashing cursor is the time to be edited)

B. Press "Prog" 4 times. The day indicator will point to Saturday:

C. Press "Prog#" 5 times to change the program from program 1 to program 6

D. Now you can set the time shown to economy

temperature by pressing "B" or press "A" to set it to comfort temperature. Or you can use "h" key to pass through the time without changing the setting.

Since we want to set 13:00 to 18:00 to comfort temperature and the remains to economy temperature, press 13 times. 00:00 to 12:00 will be programmed to economy temperature

Press "h" or "A" 6 times to move the flashing point to 19:00:

E. Finally, press "B" 5 times to set the remains of the day to economy temperature:

0c

0 6 12 18 24

. .

0 6 12 18 24

. .

AURATON 2005, AURATON 2005 TX Plus - Familiar with your AURATON37 EN

Page 11: Auraton_2005

F. Press OK or leaving no key pressed for 15 seconds, the thermostat will return to normal operation mod.

Note: Programs 0, 1, 2, 3, 4, 5 are preset

programs. "A" and "B" cannot be used to edit them. But "h" key is still active.

2.10 Manual Override

Method no. 1:

Press "A" to select comfort temperature. Press "B" to select economy temperature. The current temperature mode will be overrode until the next set point of the program comes. Press OK to clear override.

Method no. 2:

Press "A" or "B" and hold for 2 seconds. "01" will apear on the LCD. It means that manual override will be forced for one hour. The number of hours (from 1 to 24) can be set by pressing/holding the button.

PROG0 6 12 18 24

0c

Ni Po Wt Śr Cz Pt So

heating device

AURATON 2005 RX Plus

AURATON 2005 TX Plus

reciver radio signal temperature controllertransmitter

AURATON 2005 TX RX Plus - Installation 38

3. Installation instructionsAURATON 2005 TX RX Plus

Programmable Temperature Controller AURATON

2005 TX Plus is almost the same product as AURATON 2005. The only difference is way of transmitting on/off signal. AURATON 2005 TX Plus uses radio waves. That eliminates wires between AURATON 2005 TX Plus and controlled device. Receiver of radio waves is module called AURATON

2005 RX Plus. Range of AURATON 2005 TX Plus is very high but depends on materials that house is made of. AURATON 2005 TX Plus with AURATON

2005 RX Plus module is capable to hold range of over 100mtrs outdoor and up to 30mtrs indoor.

EN

Page 12: Auraton_2005

4. Appearance of AURATON 2005 RX Plus

NC

NO

CO

M

front back

2

1

3

4

5

6

AURATON 2005 RX Plus - Appearance

3.1 Connecting AURATON 2005 RX Plus

to a heating device

Warning:

Unplug heating device from power supply before mounting receiver.

Find connectors on the back of AURATON 2005 RX

Plus under the plastic cover.

In most cases connect heating device to NO and COM connectors.

NO

COM

NC

NO

COM

NC

39 EN

Page 13: Auraton_2005

5. Turning on AURATON 2005 TX RX Plus for the first time

1. Insert new ALKALINE batteries in AURATON 2005 TX Plus

2. Plug in AURATON 2005 RX Plus and wait 10 minutes to achive full range by transmitter

3. Yellow LED indicates that transmitter is within receivers range . LED blinks once a minute. The transmitter is out of range (or batteries of AURATON 2005 TX Plus are low) if LED blinks every second or does not blink. The factory set communication code is „085”. If there are troubles with communication code can be changed – see chapter no. 6.

4. Red LED indicates that receiver AURATON

2005 RX Plus is supplied with 230VAC.

5. Green LED indicates that heating device is on.

AURATON 2005 TX RX Plus - Turning on for the first time 40

1. Antenna for communication with AURATON

2005 TX Plus.

2. green LED – indicates operating status of heating device

red LED – indicates power supply status of AURATON 2005 RX Plus

yellow LED – indicates communication status with AURATON 2005 TX Plus

3. Additional electric socket switch

4. Additional electric socket – can be used to supply any 230VAC device (MAX.5A).

5. Plastic connectors cover

6. 230VAC plug

EN

Page 14: Auraton_2005

AURATON 2005 TX RX Plus - Setting communication code

4. Press and hold "PROG#" again to set new communication code (range between 001 to 255).

5. Plug in receiver AURATON 2005 RX Plus to 230VAC and press OK button on the transmitter AURATON 2005 TX Plus (after 10 seconds LCD will return to normal mode).

6. AURATON 2005 RX Plus will confirm programming new code by blinking yellow diode for 3 seconds.

7. Plastic holder forAuraton 2005 TX plus

There is a plastic holder for AURATON 2005 TX Plus in the box.

Notes:

If AURATON 2005 RX Plus will not receive ON/OFF signal from AURATON 2005 TX Plus for 5 minutes (cycles) the heating device will be turned off. System will return to its normal operation after interfere disapear. AURATON 2005 TX Plus sends digital signals that is why many other devices can work within its range without interfere.

6. Setting communication code

There is a factory set communication codet - „085”. In case of interfere with other device (e.g. another AURATON 2005 TX Plus) preset code can be changed:

1. Unplug receiver AURATON 2005 RX Plus from 230VAC.

2. Slide transmitters AURATON 2005 TX Plus cover.

3. Press and hold "PROG#" for 2 seconds, communication code will be displayed on LCD (factory set code is 085).

41 EN

Page 15: Auraton_2005

8. How to connect AURATON 2005

8.1 How to connect AURATON 2005 directly to a heating device.

AURATON 2005

AURATON 2005 - How to connect 42

NO

COMNC

HEATING DEVICE

EN

Page 16: Auraton_2005

8.2 How to connect AURATON 2005 to single-phase heating device with working load exceeding 5A thought magnetoelectric relay.

AURATON 2005

NO

COMNC

POWER SUPPLY

max ~220V

HEATING DEVICE

MAGNETOELECTRICRELAY

AURATON 2005 - How to connect43 EN

Page 17: Auraton_2005

8.3 How to connect AURATON 2005 to three-phase heating device through three-phase contactor.

44

AURATON 2005

NO

COMNC

THREE PHASE CONNECTOR

max ~220V

RST

HEATING DEVICE

AURATON 2005 - How to connect EN

Page 18: Auraton_2005

8.4 How to connect AURATON 2005 directly to gas water heating device powered by ~220V and equipped with circulating pump.

NO

COMNC

AURATON-2005

GASWATER DEVICE

~220V

max ~220V 5A

CIRCULATING PUMP

AURATON 2005 - How to connect45 EN

Page 19: Auraton_2005

NO

COM

NC

1

PROG0 6 12 18 24

0c

Ni Po Wt Śr Cz Pt So

2

HEATING DEVICE

1. AURATON 2005 RX Plus (receiver)2. AURATON 2005 TX Plus

AURATON 2005 TX RX Plus - How to connect 46

8.5 How to connect AURATON 2005 TX RX Plus with a heating device

EN

Page 20: Auraton_2005

9. Specification

1. Temperature measurement rangeO O0-34.75 C (0,25 C step)

2. Temperature control rangeO O5-30 C (0,25 C step)

3. Temperature accuracyO+/- 1 C

4. Clock accuracy+/- 70 seconds/month

5. Program6 preset, 3 user-define

6. Switching spanO O0,5 C or 1 C

7. Control modeHeating or Cooling system

8. Minimum air-con. cycle time5 minutes

9. Switching230VAC 50Hz 5A resistive

10. Dimensions 154 x 80 x 30 (mm) (W x H x D)

11. Operation temperatureO0 - 45 C

12. Storage temperatureO-20 - 60 C

13. Operating humidity5 - 90% non-condensing

AURATON 2005, AURATON 2005 TX RX Plus - Specification47 EN

Page 21: Auraton_2005

DE

KL

AR

AC

JA

ZG

OD

NO

ŚC

I W

EE

C D

EC

LA

RA

TIO

N O

F C

ON

FO

RM

ITY

NR

: 0

41

46

Niż

ej p

od

pis

an

y, re

pre

ze

ntu

jąc

y w

ym

ien

ion

eg

o p

rod

uc

en

ta / T

he

un

de

rsig

ne

d,

rep

rese

ntin

g th

e fo

llow

ing

ma

nu

factu

rer:

LA

RS

, A

nd

rze

j S

zym

sk

iu

l. C

złu

ch

ow

sk

a 1

2, 6

0-4

34

Po

zn

, P

ols

ka

nin

iejs

zy

m d

ek

laru

ję z

pe

łną

od

po

wie

dzia

lno

śc

ią, że

wy

rob

y / h

ere

with

de

cla

res

un

de

r o

ur

sole

re

sp

on

sib

ility

th

at th

e p

rod

ucts

:

Ele

ktr

on

iczn

e r

eg

ula

tory

te

mp

era

tury

, ty

pu

/ E

lectr

on

ic p

rog

ram

ma

ble

th

erm

ost

ats

, ty

pe

:A

ura

ton

20

05

/p, A

ura

ton

20

16

/p, A

ura

ton

20

20

/p

zg

od

ne

z p

os

tan

ow

ien

iam

i n

as

tęp

ują

cy

ch

Dy

rek

tyw

WE

/ a

re in

co

nfo

rmity

with

th

e

pro

visio

ns o

f th

e fo

llow

ing

EC

dire

ctiv

es:

Dy

rek

tyw

a N

isk

on

ap

ięc

iow

a L

VD

73

/23

/EW

G z

e z

mia

na

mi 9

3/6

8/E

WG

/ th

e

Eu

rop

ea

n L

ow

Vo

lta

ge

Dire

ctiv

e 7

3/2

3/E

EC

am

en

de

d b

y 9

3/6

8/E

EC

.(R

ozp

orz

ąd

zen

ie M

inis

tra

Go

sp

od

ark

i z

dn

. 1

5.1

2.2

00

5 w

sp

raw

ie z

as

ad

nic

zyc

h

wy

ma

ga

ń d

la s

prz

ętu

ele

ktr

yc

zn

eg

o –

Dz.

U. N

r 2

59

, p

oz.

21

72

)

Dy

rek

tyw

a K

om

pa

tyb

iln

ci E

lek

tro

ma

gn

ety

czn

ej 8

9/3

36

/EW

G z

e z

mia

na

mi

91

/26

3/E

WG

, 9

2/3

1/E

WG

, 9

3/6

8/E

WG

/ th

e E

lect

rom

ag

ne

tic C

om

pa

tibili

ty D

ire

ctiv

e

89

/33

6/E

EC

am

en

de

d b

y 9

1/2

63

/EE

C, 9

2/3

1/E

EC

, 9

3/6

8/E

EC

(Ro

zp

orz

ąd

zen

ie M

inis

tra

Tra

ns

po

rtu

i B

ud

ow

nic

twa

z d

n. 2

7.1

2.2

00

5 w

sp

raw

ie

do

ko

ny

wa

nia

oc

en

y z

go

dn

ci a

pa

ratu

ry z

za

sa

dn

iczy

mi w

ym

ag

an

iam

i d

ot.

k

om

pa

tyb

iln

ci e

lek

tro

ma

gn

ety

czn

ej o

raz s

po

so

bu

je

j o

zn

ak

ow

an

ia –

D

z.U

. N

r 2

65

, p

oz. 2

22

7 )

No

rmy

zh

arm

on

izo

wn

e z

as

tos

ow

an

e d

o w

yk

aza

nia

zg

od

no

śc

i z

wy

ma

ga

nia

mi

za

sa

dn

iczy

mi w

ym

ien

ion

yc

h D

yre

kty

w / H

arm

on

ize

d s

tan

da

rds

use

d fo

r sh

ow

ing

co

mp

lian

ce w

ith

th

e e

sse

ntia

l re

qu

ire

me

nts

in

th

e s

pe

cifie

d d

ire

ctiv

es:

P

N-E

N 6

07

30

-1:2

00

2

(EN

60

73

0-1

:20

00

+A

11

:20

02

)P

N-E

N 6

07

30

-2-9

:20

02

(EN

60

73

0-2

-9 :

95

+A

1:9

6+

A2

:97

+A

11

:97

+A

12

:01

)

Ozn

ac

ze

nie

ro

ku

, w

któ

rym

na

nie

sio

no

zn

ak

CE

/ Y

ea

r in

wh

ich

th

e C

E m

ark

ing

wa

s a

ffix

ed

: 0

4M

iejs

co

wo

ść

, d

ata

/ P

lace

, d

ate

: P

ozn

, 0

1.0

9.2

00

6

An

drz

ej S

zym

sk

i, W

łaś

cic

iel

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

---

Na

zwis

ko

, fu

nk

cja

i p

od

pis

os

ob

y u

po

wa

żnio

ne

j / N

am

e, fu

nctio

n a

nd

sig

na

ture

of

au

tho

rise

d p

ers

on

Page 22: Auraton_2005

DE

KL

AR

AC

JA

ZG

OD

NO

ŚC

I W

EE

C D

EC

LA

RA

TIO

N O

F C

ON

FO

RM

ITY

NR

: 0

414

5

Niż

ej p

od

pis

an

y, re

pre

zen

tują

cy

wym

ien

ion

eg

o p

rod

uce

nta

/ T

he u

nd

ers

igned

, re

pre

sentin

g the

follo

win

g m

anu

fact

ure

r:

LA

RS

, A

nd

rzej S

zym

ski

ul. C

złu

ch

ow

ska 1

2, 60-4

34

Po

zna

ń, P

ols

ka

nin

iejs

zym

dek

laru

ję z

pełn

ą o

dp

ow

ied

zialn

cią

, że

wyro

by

/ h

ere

with

decla

res u

nd

er

ou

r so

le

resp

onsi

bili

ty tha

t th

e p

rodu

cts:

Ele

ktr

on

iczn

e r

eg

ula

tory

tem

pe

ratu

ry, ty

pu

/ E

lect

ron

ic p

rog

ram

mab

le th

erm

ost

ats

, ty

pe:

Au

rato

n 2

00

5 T

X P

lus, A

ura

ton

2020

TX

Plu

s

zg

od

ne

z p

osta

no

wie

nia

mi n

astę

pu

jąc

yc

h D

yre

kty

w W

E / a

re in

confo

rmity

with

the

pro

vis

ion

s o

f th

e fo

llow

ing E

C d

irect

ive

s:

Dy

rek

tyw

a N

isk

on

ap

ięc

iow

a L

VD

73/2

3/E

WG

ze

zm

ian

am

i 9

3/6

8/E

WG

/ the E

uro

pe

an L

ow

V

olta

ge D

ire

ctiv

e 7

3/2

3/E

EC

am

end

ed b

y 9

3/6

8/E

EC

.(R

ozp

orz

ąd

zen

ie M

inis

tra G

osp

od

ark

i z

dn

. 1

5.1

2.2

00

5 w

sp

raw

ie z

asad

nic

zy

ch

w

ym

ag

dla

sp

rzę

tu e

lek

try

czn

eg

o –

Dz.

U. N

r 259

, p

oz.

2172

)

Dy

rek

tyw

a K

om

pa

tyb

iln

ci E

lektr

om

ag

nety

czn

ej 8

9/3

36

/EW

G z

e z

mia

nam

i 9

1/2

63

/EW

G,

92/3

1/E

WG

, 93

/68

/EW

G/ th

e E

lectr

om

agn

etic

Com

patib

ility

Direct

ive 8

9/3

36/E

EC

am

en

de

d b

y 9

1/2

63

/EE

C, 92

/31

/EE

C, 93

/68

/EE

C(R

ozp

orz

ąd

zen

ie M

inis

tra T

ran

sp

ort

u i B

ud

ow

nic

twa z

dn

. 2

7.1

2.2

005 w

sp

raw

ie

do

ko

ny

wan

ia o

ce

ny z

go

dn

ci a

pa

ratu

ry z

za

sad

nic

zym

i w

ym

ag

an

iam

i d

ot.

k

om

paty

biln

ośc

i ele

ktr

om

ag

nety

czn

ej o

raz

sp

os

ob

u je

j o

znako

wan

ia –

D

z.U

. N

r 26

5, p

oz.

2227

)

Dy

rek

tyw

a R

&T

TE

1

999

/5/W

E / D

irect

ive

19

99

/5/E

C o

f th

e E

uro

pean

Parlia

ment a

nd

o

f th

e C

oun

cil o

f 9

Marc

h 1

999 o

n r

ad

io e

qu

ipm

en

t an

d tele

com

mu

nic

atio

ns te

rmin

al

equ

ipm

en

t an

d the

mu

tual r

eco

gniti

on

of th

eir c

on

form

ity(U

sta

wa

z d

n. 16

.07

.2004

– P

raw

o t

ele

ko

mu

nik

ac

yjn

e, D

z. U

. N

r 1

71 p

oz. 18

00 o

raz

Ro

zpo

rzą

dze

nie

Min

istr

a In

fra

str

uk

tury

z d

n. 1

5.0

4.2

00

4 w

sp

raw

ie d

oko

ny

wa

nia

o

cen

y z

go

dn

ośc

i te

lek

om

un

ikac

yjn

ych

urz

ąd

zeń

ko

ńco

wych

prz

ezn

aczo

nyc

h d

o

do

łącza

nia

do

za

ko

ńc

zeń

sie

ci p

ub

liczn

ej i u

rzą

dze

ń r

ad

iow

ych

z z

asa

dn

iczy

mi

wy

mag

an

iam

i o

raz ic

h o

zna

ko

wa

nia

– D

z. U

. N

r 7

3 p

oz.

65

9)

No

rmy

zh

arm

on

izo

wn

e z

asto

so

wan

e d

o w

ykaza

nia

zg

od

no

ści z

wym

ag

an

iam

i za

sa

dn

iczy

mi

wy

mie

nio

ny

ch

D

yre

kty

w / H

arm

oniz

ed

sta

nd

ard

s use

d for

sho

win

g c

om

plia

nce w

ith the e

sse

ntia

l re

qu

ire

me

nts

in the s

pecifi

ed d

irect

ive

s:

PN

-EN

60

73

0-1

:20

02

(EN

60

73

0-1

:20

00

+A

1:2

00

2)

PN

-EN

60

73

0-2

-9:2

00

2(E

N 6

07

30

-2 9

:19

95

+A

1:1

99

6+

A2

:19

97

+A

11

:19

97

+A

12

:20

01

)P

N-E

N 5

50

22

:20

00

+A

1+

A2

(EN

55

02

2:1

99

8+

A1

+A

2)

PN

-ET

SI E

N 3

00

22

0-3

V1

.1.1

.:2

00

4(E

TS

I E

N 3

00

22

0-3

V1

.1.1

:20

00

)

Ozn

ac

zen

ie r

ok

u, w

któ

rym

na

nie

sio

no

zn

ak C

E / Y

ear

in w

hic

h the C

E m

ark

ing

was a

ffix

ed

: 0

4M

iejs

co

wo

ść, d

ata

/ P

lace

, da

te: P

ozn

, 0

1.0

9.2

00

6

An

drz

ej S

zym

ski, W

łaś

cic

iel

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

---

Na

zwis

ko

, fu

nk

cja

i p

od

pis

oso

by

up

ow

ażn

ion

ej / N

am

e, fu

nct

ion

and

sig

na

ture

of auth

orised

p

ers

on

Page 23: Auraton_2005

Urządzenia objęte instrukcją są oznaczone zgodnie z Dyrektywą Europejską 2002/96/WE oraz polską Ustawą o zużytym sprzęcie elektrycznym i elektronicznym symbolem przekreślonego kontenera na odpady.

Takie oznakowanie informuje, że sprzęt ten, po okresie jego użytkowania nie może być umieszczany łącznie z innymi odpadami pochodzącymi z gospodarstwa domowego.

Użytkownik jest zobowiązany do oddania go prowadzącym zbieranie zużytego sprzętu elektrycznego i elektronicznego. Prowadzący zbieranie, w tym lokalne punkty zbiórki, sklepy oraz gminne jednostki, tworzą odpowiedni system umożliwiający oddanie tego sprzętu.

Właściwe postępowanie ze zużytym sprzętem elektrycznym i elektronicznym przyczynia się do uniknięcia szkodliwych dla zdrowia ludzi i środowiska naturalnego konsekwencji, wynikających z obecności składników niebezpiecznych oraz niewłaściwego składowania i przetwarzania takiego sprzętu.

Page 24: Auraton_2005

Serwis: tel 061 840 40 55 (pn.- pt. 8.00-16.00)WWW.AURATON.PL

Warunki Gwarancji:

1. Gwarancji udziela się na okres 36 miesięcy od daty sprzedaży.

2. Reklamowany regulator wraz z kartą gwarancyjną, należy dostarczyć do punktu sprzedaży za pośrednictwem poczty (w przypadku sterownika bezprzewodowego TX RX należy dostarczyć odbiornik i nadajnik).

3. Termin wykonania naprawy wynosi 14 dni roboczych od daty zgłoszenia reklamacji.

4.Gwarancja traci ważność w przypadku uszkodzenia mechanicznego, niewłaściwej eksploatacji i dokonania napraw przez osoby nieuprawnione.

5. Wszystkie zmiany i poprawki w treści karty gwarancyjnej są ważne jedynie wtedy gdy są dokonane przez uprawnioną osobę, opatrzone podpisem i stemplem.

AURATON 2005

AURATON 2005 TX RX Plus