Auger electron spectroscopy
SharifUniversity ofTechnology
Kamal Asadi Pakdel
![Page 3: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/3.jpg)
History Of The Auger spectroscopy
Lise Meitner Pierre Auger
![Page 4: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/4.jpg)
The Auger Process
K
L
M
Vacuum Level
Eject core electron
Higher electronfalls into hole
Another higher level electron is ejected to carry away excess energy.
Measure kinetic energy of ejected electron.
IncidentElectronBeam (5 kV)
Ekinetic = E(K) - E(L) - E(L)
![Page 5: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/5.jpg)
KE of Auger electron ~ -EA – EB
EC
Emitted energy of relaxed electron
Energy needed to overcome BE of Auger electron
NOTE: KE of Auger electron is not proportional to the primary beam energy
Different from XPS
Kinetic Energy Of The Auger Electron
![Page 6: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/6.jpg)
KLM
Source of auger electron
Origin of relaxing electron
Initial core hole
Four main Auger series:KLL, LMM, MNN, NOO
As the atomic number increases,the number possible electron transfers are also high.
![Page 8: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/8.jpg)
electron escape depths
![Page 9: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/9.jpg)
In addition, the entire system must be shielded from the earth’s magnetic field
AES instrument schematic configuration
![Page 10: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/10.jpg)
Auger Instrumentation
UHV environment Electron gun Electron energy
analyzer Read-out system
![Page 11: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/11.jpg)
Electron Gun Properties
Stability
Brightness
Longevity
Mono-energetic
![Page 12: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/12.jpg)
Commercial Sources
Thermionic emitter
Lanthanum hexaboride
emitter
![Page 13: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/13.jpg)
Electron energy analyzer
Cylindrical Mirror Analyzer
(CMA)
HemisphericalSector analyzer
(HSA)
Electron energy analyzer
![Page 14: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/14.jpg)
Electron energy analyzer
![Page 15: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/15.jpg)
Cylindrical mirror analyzer(CMA)
![Page 16: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/16.jpg)
![Page 17: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/17.jpg)
(HSA) henmispherical scefor alualyser
![Page 18: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/18.jpg)
Read-out system
![Page 19: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/19.jpg)
• Qualitative Identification of Elements
Analytical Information
Ex:
From the differential AES spectrum Ni, Fe and Cr have been identified.
Ni
Fe
Cr
![Page 20: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/20.jpg)
Chemical Shift
Auger spectra from elemental silicon and oxidized silicon showing the chemical shift which occurs in the oxide
![Page 21: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/21.jpg)
Quantification
External standard (1
Sensitivity factor(2
![Page 22: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/22.jpg)
Sensitivity factor of elements
![Page 23: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/23.jpg)
Surface AnalysisAuger Electron Spectroscopy (AES)
Depth Profiling
E- GunAr+ Sputter Gun
![Page 24: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/24.jpg)
![Page 25: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/25.jpg)
•The primary electron beam is focussed on the surface and scanned (similarly to SEM).
•At each point (pixel), an Auger spectrum is recorded.
•Peaks that correspond to a specific element are indentified and their intensity measured.
•A colour is assigned to each element
•The brightness of colour at each pixel is proportional to the intensity of the corresponding Auger peak.
•Result: multicoloured images as chemical element maps.
Scanning auger microscopy(SAM):
![Page 26: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/26.jpg)
Limits of
Experimet
Spectral peak
overlap
Elemental
Detection
Sensitivity
Sample chargin
g
Electron Beam
Artifacts
High vapor
pressure
samples
![Page 27: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/27.jpg)
XPS vs. Auger
![Page 28: auger electron spectroscopy (AES)](https://reader035.fdocuments.us/reader035/viewer/2022081421/55896f95d8b42afe068b464b/html5/thumbnails/28.jpg)