ator 056 °C emp. +5 °C 1347 2 °C - Berlinger USA · 2 0000 max. 55 °C Ext. Sensor 2 09192015!...

1
55 0 00 0 max. °C Ext. Sensor 5 1 0 0 2 19 9 1 21 8 ! 2 - 011 0 35 1 °C min. Ext. Sensor ! 2 5 1 0 0 2 19 9 1 21 8 ! 2nd press 2 Quick User guide • Fridge-tag ® 2 • Fridge-tag ® 2 L 5 1 0 0 2 19 6 °C 056 1 47 3 5 1 0 0 2 19 6 088 1 42 5 °C ! ! 20160413_V1 Refrigerator Goal Temp. +5 °C Freezer Goal Temp. -20 °C ALARM symbols, temperature alert = Max higher (HI) temperature ALARM = MIN lower (LO) temperature ALARM = ALARM sensor disconnected for +15 minutes The arrow appears under today and / or the day an ALARM occurs Press the READ button 3 times to record your check • 1st press: see UP arrow blink = HI temp. so far today • 2nd press: see DOWN arrow blink = LO temp. so far today • 3rd press: records in memory the time of your manual check • There will be an UP or DOWN arrow under today in the upper right of the screen indicating a HI or LO ALARM 1st press: see UP arrow blink = HI temp. so far today 2nd press: see DOWN Arrow blink = date & time of the alarm 3rd press: see DOWN arrow blink & dur = duration of ALARM and the lowest temperature during that alarm 4th press: clears the X and records in memory 1st Press Press the READ button 4 or 5 times to clear the X and record your check. Press READ 3 times Read history (record daily checks (2x) in memory and clear an X if alarmed) Recording daily checks Connect the Fridge-tag ® 2 / 2L via USB with your PC / MAC Berlinger USA LLC 222 Turnpike Road Suite 3 Westborough, MA 01581 USA Tel. +1 508 366 0084 Fax +1 508 366 0087 [email protected] www.berlinger.com 3rd press • A Fridge-tag ® 2 records an AM or PM for morning or afternoon checks • A Fridge-tag ® 2 L records the actual time it is checked in the morning and in the afternoon. Clearing the X / Example of a LO ALARM Downloading the report Click on the Fridge-tag file to open it Download the report from the Fridge-tag ® device by connecting it to any PC / MAC. Headquarters: Berlinger & Co. AG, 9608 Ganterschwil, Switzerland Reading the display during measurement OK display ALARM display • Fridge-tag ® 2 = 60 day report • Fridge-tag ® 2 L = 56 day report (with 8 weekly graphs) If both arrows are present then it is typically an ALARM for the external sensor being disconnected for more than 15 minutes. Double arrows need 5 presses of READ to clear the X. The following information is visible on screen: temperatures are OK • Current date: 06.19.2015 • Current time in military format:13:47 • Current temperature: + 5.6 ° C If an alarm occurs the following additional symbols appear on screen: STEP 1 STEP 2 STEP 3 Double click on the PDF file to open the report. Note: store reports for 3 years to be VFC compliant To change date / time or Celsius to Fahrenheit, view videos at: www.berlinger.com/videos Support X 4th press 1 3 2 4

Transcript of ator 056 °C emp. +5 °C 1347 2 °C - Berlinger USA · 2 0000 max. 55 °C Ext. Sensor 2 09192015!...

2

550 000max.

°C

Ext. Sensor

2

5100 2199

1 218!

2

-0110 351 °Cmin.

Ext. Sensor

!

2

5100 2199

1 218!2nd press

2

-0110 351 °Cmin.

Ext. Sensor

!

Quick User guide• Fridge-tag® 2• Fridge-tag® 2 L

2

5100 2196

°C0561 473

!

2

5100 2196

0881 425 °C!

!!

! !

20160413_V1

! !!

!

! !

RefrigeratorGoal Temp.

+5 °C

Freezer

Goal Temp.

-20 °C

• ALARM symbols, temperature alert• = Max higher (HI) temperature ALARM• = MIN lower (LO) temperature ALARM

• = ALARM sensor disconnected for +15 minutes

The arrow appears under today and / or the day an ALARM occurs

Press the READ button 3 times to record your check• 1st press: see UP arrow blink = HI temp. so far today• 2nd press: see DOWN arrow blink = LO temp. so far today• 3rd press: records in memory the time of your manual check

• There will be an UP or DOWN arrow under today in the upper right of the screen indicating a HI or LO ALARM

1st press: see UP arrow blink = HI temp. so far today2nd press: see DOWN Arrow blink = date & time of the alarm3rd press: see DOWN arrow blink & dur = duration of ALARM and the lowest temperature during that alarm4th press: clears the X and records in memory

1st Press

Press the READ button 4 or 5 times to clear the X and record your check.

Press READ 3 times

Read history (record daily checks (2x) in memory and clear an X if alarmed)Recording daily checks

Connect the Fridge-tag® 2 / 2L via USB with your PC / MAC

Berlinger USA LLC222 Turnpike RoadSuite 3Westborough, MA 01581 USA

Tel. +1 508 366 0084Fax +1 508 366 [email protected] www.berlinger.com

3rd press

• A Fridge-tag® 2 records an AM or PM for morning or afternoon checks• A Fridge-tag® 2 L records the actual time it is checked in the morning and in the afternoon.

Clearing the X / Example of a LO ALARM

Downloading the report

Click on the Fridge-tag file to open it

Download the report from the Fridge-tag® device by connecting it to any PC / MAC.

Headquarters: Berlinger & Co. AG, 9608 Ganterschwil, Switzerland

Reading the display during measurementOK display ALARM display

• Fridge-tag® 2 = 60 day report• Fridge-tag® 2 L = 56 day report (with 8 weekly graphs)

If both arrows are present then it is typically an ALARM for the external sensor being disconnected for more than 15 minutes. Double arrows need 5 presses of READ to clear the X.

The following information is visible on screen:

• temperatures are OK• Current date: 06.19.2015• Current time in military format:13:47• Current temperature: +5.6 °C

If an alarm occurs the following additional symbols appear on screen:

STEP 1 STEP 2 STEP 3

Double click on the PDF file to open the report. Note: store reports for 3 years to be VFC compliant

To change date / time or Celsius to Fahrenheit, view videos at: www.berlinger.com/videos

Support

X

4th press