atm_links_rnc450_DN0634547_03A_en.pdf

28
8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 1/28  ATM links and LAN connections in RNC450 DN0634547 Issue 03A Approval Date 2011-12-08 Confidential Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo- nents. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.

Transcript of atm_links_rnc450_DN0634547_03A_en.pdf

Page 1: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 1/28

 

ATM links and LAN connections in

RNC450

DN0634547

Issue 03A

Approval Date 2011-12-08

Confidential

Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of

its products and services. We would like to encourage you as our customers and users to join

us in working towards a cleaner, safer environment. Please recycle product packaging and

follow the recommendations for power use and proper disposal of our products and their compo-

nents.

If you should have questions regarding our Environmental Policy or any of the environmental

services we offer, please contact us at Nokia Siemens Networks for any additional information.

Page 2: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 2/28

2 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808df478

Confidential

The information in this document is subject to change without notice and describes only the

product defined in the introduction of this documentation. This documentation is intended for the

use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

in any form or means without the prior written permission of Nokia Siemens Networks. The

documentation has been prepared to be used by professional and properly trained personnel,

and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

customer comments as part of the process of continuous development and improvement of the

documentation.

The information or statements given in this documentation concerning the suitability, capacity,

or performance of the mentioned hardware or software products are given "as is" and all liability

arising in connection with such hardware or software products shall be defined conclusively and

finally in a separate agreement between Nokia Siemens Networks and the customer. However,

Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

contained in the document are adequate and free of material errors and omissions. Nokia

Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-

TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-

RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

IN IT.

This documentation and the product it describes are considered protected by copyrights and

other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2013/2/25. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources

of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle

this product and only after having carefully read the safety information applicable to this

product.

The safety information is provided in the Safety Information section in the “Legal, Safety

and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder

andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch

geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-

anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,

Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-

satzes.

Page 3: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 3/28

DN0634547 3

 ATM links and LAN connections in RNC450

Id:0900d805808df478

Confidential

Table of contentsThis document has 28 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.1 Introduction to ATM links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.2 Notations used in the lists of SFU ATM links. . . . . . . . . . . . . . . . . . . . . . 6

1.3 Notations used in the l ists of MXU ATM links . . . . . . . . . . . . . . . . . . . . . 7

1.4 Notations used in the lists of LAN connections . . . . . . . . . . . . . . . . . . . . 8

2 Use of SFU ATM links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3 Use of MXU ATM links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

4 LAN connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 4: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 4/28

4 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808df478

Confidential

List of tablesTable 1 Columns in the list of SFU ATM links . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Table 2 Columns in the list of MXU ATM links . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Table 3 Explanation of columns in the list of LAN links . . . . . . . . . . . . . . . . . . . . 8

Table 4 SFU ATM links in RNC 450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Table 5 MXU ATM links in MXU 2 and MXU 3 (RNAC subrack 2) . . . . . . . . . . . 12

Table 6 MXU ATM links in MXU 0 and MXU 1 (RNAC subrack 1) . . . . . . . . . . . 14

Table 7 MXU ATM links in MXU 4 and MXU 5 (RNAC subrack 3) . . . . . . . . . . . 16

Table 8 MXU ATM links in MXU 6 and MXU 7 (RNAC subrack 4) . . . . . . . . . . . 17

Table 9 MXU ATM links in MXU 8 and MXU 9 (RNBC subrack 1) . . . . . . . . . . . 19

Table 10 MXU ATM links in MXU 10 and MXU 11 (RNBC subrack 2) . . . . . . . . . 21

Table 11 MXU ATM links in MXU 12 and MXU 13 (RNBC subrack 3) . . . . . . . . . 22

Table 12 MXU ATN links in MXU 14 and MXU 15 (RNBC subrack 4) . . . . . . . . . 24

Table 13 LAN port use of ESA40-A/ESA24 (RNAC, with ESA40-A 0/ESA24 0 in sub-rack 1 and ESA40-A 1/ESA24 1 in subrack 2) . . . . . . . . . . . . . . . . . . . . 26

Table 14 LAN port use of ESA40-A/ESA24 (RNBC, with ESA40-A 0/ESA24 0 in

RNAC subrack 1 and ESA40-A 1/ESA 24 1 in RNAC subrack 2) . . . . . 27

Page 5: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 5/28

DN0634547 5

 ATM links and LAN connections in RNC450 Summary of changes

Id:0900d805808e1b87

Confidential

Summary of changesChanges between document issues are cumulative. Therefore, the latest document

issue contains all changes made to previous issues.

Note that our issue numbering system, safety information, and product naming practice

are changing. For more information, see Guide to WCDMA and I-HSPA RAN Operating

Documentation.

Change between Issue 03 (2011-01-06, RU30) and 03A (2011-12-08, RU30)

Document name is changed to ATM links and LAN connections in RNC450 . And

description part in this document is updated.

Introduction(1)

Chapter name is changed to Introuduction.

Section of Notations used in the lists of ATM links is divied into two sections Notations

used in the lists of SFU ATM links and Notations used in the lists of MXU ATM links.

SFU ATM links(2)

Chapter name is changed to SFU ATM links.

MXU ATM links(3)

Chapter name is changed to MXU ATM links.

LAN connections(4)

Chapter name is changed to LAN connections.

Changes between issue 2-1 and issue 03

CCP1D-A, SF10E, ESA40-A and CDSP-DH related information is added.

NEMU related information is removed.

The LAN connection list is updated.

Changes between issue 2-0 and issue 2-1

RRMU is replaced by ICSU in MXU ATM links.

RRMU is replaced by RSMU in LAN connections.

NIS1(P) is replaced by NPGE(P) in SFU ATM links.

NPGE(P) added in LAN connections.

Page 6: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 6/28

6 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b89

Confidential

Introduction

1 IntroductionThis document provides lists of the asynchronous transfer mode (ATM) links and LAN

connections in the RNC450. Lists of ATM links include Switching Fabric Unit (SFU) ATM

link lists and Multiplexer Units (MXU) ATM links lists in RNC450.

For more information on the configurations and equipment of the RNC450, see Equip-

ment Lists for RNC450, Cable Lists for RNC450 , andWCDMA IPA-RNC Engineering

Description.

1.1 Introduction to ATM links

SFU ATM links

The ATM SFU provides the ATM cell switching functionality. It provides 2N redundancy.

 And it is non-blocking at ATM connection level, which means if input and output channel

are available the connection can be established. The ATM SFU supports point-to-pointand point-to-multipoint connection topologies, as well as differentiated handling of

various ATM service categories. High capacity network interface units and ATM Multi-

plexer units are connected to the redundant SFU.

In RNC450, SFU is implemented in plug-in unit SF10 and SF10E. SF10 provides 16

duplicated (622 Mbit/s) ATM ports. And SF10E provides 16 duplicated (622 Mbit/s) ATM

ports and 8 high speed (2.5 Gbit/s) ATM ports.

MXU ATM links

The ATM MXU multiplexes traffic from tributary units to the SFU. This enables the effi-

cient usage of switching resources for low bit rate network interface units and computer

units with small to moderate bandwidth requirements. The ATM MXU also has ATMlayer processing functionality, such as policing, statistics, OAM, buffer management and

scheduling. Control computers, signal processing units and low bit rate network inter-

face units are connected to the ATM SFU via MXU.

In RNC450, MXU is implemented in plug-in unit MX622-D. MX622-D provides 19(0-155

Mbit/s) ATM ports.

1.2 Notations used in the lists of SFU ATM links

The table of SFU ATM links has two main columns: SFU  and FU using the port . SFU is

2N redundancy unit. FU can connect to SFU via either variant. The Note column applies

to both SFUs.

The four sub-columns for SFU :

 • Port no. : It indicates the index number of the high speed port (0-15).

SFU FU using the port Note

Port

no.

No. Slot Cabling

position

FU Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 1 Columns in the list of SFU ATM links

Page 7: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 7/28

DN0634547 7

 ATM links and LAN connections in RNC450 Introduction

Id:0900d805808e1b89

Confidential

 • No. : It indicates the index number of SFU (SFU 0 or SFU 1).

 • Slot : It indicates the SFU's equipping place, subrack, and slot.

• Cabling position: It indicates the cabling positions in two ways:

 •SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

The four sub-columns for  FU using the port :

 • FU : It indicates the Functional unit (FU) name with index number, for example,

NPS1 0.

 • Plug-in unit : It indicates the name of the plug-in unit which can be used.

 • Slot : It indicates the equipping place number of the plug-in unit.

 • Cabling position: It indicates the cabling positions in two ways:

 • SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

1.3 Notations used in the lists of MXU ATM links

The table below has two main columns: MXU  and FU using the port . MXU is 2N redun-

dancy unit. FU can connect via either MXU.

The four sub-columns for MXU :

 • Port no: It indicates the index number of the port (0-18).

 • No. It indicates the index number of MXU (0–15).

 • Slot : It indicates the MXU's equipping place, subrack, and slot.

• Cabling position: It indicates the cabling positions in two ways:

 • SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

The four sub-columns for FU using the port :

 • Tributary unit : It indicates the FU name with index number, for example OMU 0.

 • Plug-in unit : It indicates the name of the plug-in unit which can be used.

 • Slot : It indicates the equipping place number of the plug-in unit.

 • Cabling position: It indicates the cabling positions in two ways:

 • SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 2  Columns in the list of MXU ATM links

Page 8: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 8/28

8 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b89

Confidential

Introduction

1.4 Notations used in the lists of LAN connections

The LAN connections are shown in the form of a table. There are two main columns:

ESA40-A 0, ESA40-A 1 / ESA24 0, ESA24 1 and FU using the LAN port. The table below

covers ESA40-A and ESA24. FU can connect via either variant.

The four sub-columns for ESA40-A 0(ESA40-A 1) / ESA24 0(ESA24 1):

 • Port no.: It indicates the software port index number, 1/1/1 - 1/1/24.

 • No.: It indicates the index number of ESA40-A/ESA24.

 • Slot  : It indicates the ESA's equipping place, subrack, and slot.

 • Cabling position : It indicates the cabling positions in two ways:

 • SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

The four sub-columns for FU using the LAN port :

 • FU : It indicates the FU name including index number, for example, OMU 0.

 • Plug-in unit  : It indicates the name of the plug-in unit, for example, CCP1D-A.

 • Slot  : It indicates the FU's equipping place, subrack, and slot. • Cabling position: It indicates the cabling positions in two ways:

 • SW: cable connection coordinate used in hardware configuration management

 • HW: physical cabling equipping position

ESA40-A 0 (ESA40-A 1)

 / ESA24 0 (ESA24 1)

FU using the LAN port Note

Port no. No. Slot Cabling position FU Plug-in

unit

Slot Cabling position

SW HW SW HW

Table 3 Explanation of columns in the list of LAN links

Page 9: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 9/28

DN0634547 9

 ATM links and LAN connections in RNC450 Use of SFU ATM links

Id:0900d805808e1b8b

Confidential

2 Use of SFU ATM linksThe chapter provide a list of the SFU ATM links in RNC450.

gIn some cases, one SFU port can be used for different FUs and plug-in units. AlternativeFUs and plug-in units are presented in the same cell.

SFU FU using the port Note

Port

no.No.

Slot Cabling position FU Plug-in

unit

Slot Cabling position

SW HW SW HW

P0A SFU 0

SFU 1

1-2 B84 2.4J MXU 0 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P0B SFU 0

SFU 1

1-2 B96 2.4V MXU 1 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P1A SFU 0

SFU 1

1-2 B82 2.4G MXU 2 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P1B SFU 0

SFU 1

1-2 B94 2.4T MXU 3 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P2A SFU 0

SFU 1

1-2 B80 2.4E MXU 4 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P2B SFU 0

SFU 1

1-2 B92 2.4R MXU 5 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P3A SFU 0

SFU 1

1-2 B78 2.4C - - - - - -

P3B SFU 0

SFU 1

1-2 B90 2.4P - - - - - -

P4A SFU 0

SFU 1

1-2 B68 2.3S - - - - - -

P4B SFU 0

SFU 1

1-2 B76 2.4A - - - - - -

P5A SFU 0

SFU 1

1-2 B66 2.3Q MXU 6 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

Table 4 SFU ATM links in RNC 450

Page 10: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 10/28

10 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8b

Confidential

Use of SFU ATM links

P5B SFU 0

SFU 1

1-2 B74 2.3Y MXU 7 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P6A SFU 0

SFU 1

1-2 B64 2.3O MXU 8 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P6B SFU 0

SFU 1

1-2 B72 2.3W MXU 9 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P7A SFU 0

SFU 1

1-2 B62 2.3M MXU 10 MX622-B/

MX622-C/

MX622-D

9 B76

 (B80)

4A

(4E)

-

P7B SFU 0

SFU 1

1-2 B70 2.3U MXU 11 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P8A SFU 0

SFU 1

1-2 B52 2.3B MXU 12 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P8B SFU 0

SFU 1

1-2 B60 2.3K MXU 13 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P9A SFU 0

SFU 1

1-2 B50 2.2Z MXU 14 MX622-B/

MX622-C/

MX622-D

9 B76

(B80)

4A

(4E)

-

P9B SFU 0

SFU 1

1-2 B58 2.3H MXU 15 MX622-B/

MX622-C/

MX622-D

11 B80

(B76)

4E

(4A)

-

P10A SFU 0

SFU 1

1-2 - F16 NPGEP 0

NPGE 0

NP2GE-B 15 B103

(B115)

B0

(B2)

1)

P10B SFU 0

SFU 1

1-2 - F17 NPGEP 1

NPGE 1

NP2GE-B 15 B103

(B115)

B0

(B2)

1)

P11A SFU 0

SFU 1

1-2 - F18 NPGEP 2

NPGE 2

NP2GE-B 1 B103

(B115)

B0

(B2)

1)

P11B SFU 0

SFU 1

1-2 - F19 NPGEP 3

NPGE 3

NP2GE-B 1 B103

(B115)

B0

(B2)

1)

P12A SFU 0

SFU 1

1-2 - F20 NPGEP 4

NPGE 4

NP2GE-B 1 B103

(B115)

B0

(B2)

1)

SFU FU using the port Note

Port

no.No.

Slot Cabling position FU Plug-in

unit

Slot Cabling position

SW HW SW HW

Table 4 SFU ATM links in RNC 450 (Cont.)

Page 11: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 11/28

DN0634547 11

 ATM links and LAN connections in RNC450 Use of SFU ATM links

Id:0900d805808e1b8b

Confidential

P12B SFU 0

SFU 1

1-2 - F21 NPGEP 5

NPGE 5

NP2GE-B 1 B103

(B115)

B0

(B2)

1)

P13A SFU 0

SFU 1

1-2 - F22 NPGEP 6

NPGE 6

NP2GE-B 17 B103

(B115)

B0

(B2)

1)

P13B SFU 0

SFU 1

1-2 - F23 NPGEP 7

NPGE 7

NP2GE-B 17 B103

(B115)

B0

(B2)

1)

The values indicated in the table in brackets correspond to the SFU in brackets. In other words, to SFU 1. For instance, the

SW cabling position B76 corresponds to SFU 0, whereas B80 in brackets corresponds to SFU 1. The FU can connect via

either SFU.

1) SF10E is needed

SFU FU using the port Note

Port

no.No.

Slot Cabling position FU Plug-in

unit

Slot Cabling position

SW HW SW HW

Table 4 SFU ATM links in RNC 450 (Cont.)

Page 12: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 12/28

12 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

3 Use of MXU ATM linksThe provide lists of the MXU ATM links in RNC450.

gIn some cases, one MXU port can be used for different FUs and plug-in units. AlternativeFUs and plug-in units are presented in the same cell.

MXU 2 (MXU 3) FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit by

subrack

configura-

tion

Plug-in

unit

Slot Cabling

position

SW HW SW HW

0 MXU 2

MXU 3

9

(11)

B96 4V A2SU 2 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 2

MXU 3

9

(11)

B97 4W - HDS-B 13 B76

(B77)

4A

(4B)

1) 5)

2 MXU 2

MXU 3

9

(11)

B98 4X - HDS-C

HDS-B

14 B76

(B77)

4A

(4B)

1) 5)

3 MXU 2

MXU 3

9

(11)

B99 4Y EHU EHAT 15 B76

(B77)

4A

(4B)

-

4 MXU 2

MXU 3

9

(11)

B100 4Z OMU 1 CCP1D-A

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 2

MXU 3

9

(11)

B101 5A RSMU 1 CCP1D-A

CCP18-C

CCP18-A

8 B76

(B77)

4A

(4B)

-

6 MXU 2

MXU 3

9

(11)

B102 5B ICSU CCP1D-A

CCP18-C

CCP18-A

7 B76

(B77)

4A

(4B)

-

7 MXU 2

MXU 3

9

(11)

B103 5C GTPU 0 CCP1D-A

CCP18-C

CCP18-A

6 B76

(B77)

4A

(4B)

-

8 MXU 2

MXU 3

9

(11)

B104 5D - ESA40-A

ESA24

5 B76

(B77)

4A

(4B)

1)

9 MXU 2

MXU 3

9

(11)

B105 5E DMCU 3 CDSP-DH 4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 2

MXU 3

9

(11)

B107 5G DMCU 2 CDSP-DH 3 B76

(B77)

4A

(4B)

-

11 MXU 2

MXU 3

9

(11)

B108 5H - - 2 B76

(B77)

4A

(4B)

3)

Table 5  MXU ATM links in MXU 2 and MXU 3 (RNAC subrack 2)

Page 13: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 13/28

DN0634547 13

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

12 MXU 2

MXU 3

9

(11)

B109 5J SFU 1 SF10E

SF10

1 B76

(B77)

4A

(4B)

-

13 MXU 2 9 B110 5K MXU 3 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 3 11 B110 5K MXU 2 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 2

MXU 3

9

(11)

B111 5L ICSU 2 CCP1D-A

CCP18-C

CCP18-A

17 B76

(B77)

4A

(4B)

-

15 MXU 2

MXU 3

9

(11)

B112 5M ICSU 3 CCP1D-A

CCP18-C

CCP18-A

18 B76

(B77)

4A

(4B)

-

16 MXU 2

MXU 3

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

3)

17 MXU 2

MXU 3

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

3)

18 MXU 2

MXU 3

9

(11)

B115 5P A2SU 2 AL2S-D 12 B78

(B79)

4C

(4D)

4)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 3. For

instance, the SW cabling position B76 corresponds to MXU 2, whereas B77 in brackets corresponds to MXU

3. The unit using the port, however, can connect via either MXU.

1) The tributary unit does not use the MXU port.

2) The MXU pair is cross-connected.

3) The MXU port is not in use.

4) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

5) HDS-B is two wide slot. HDS-C is one wide slot. When HDS-C slot is used, slot 13 is empty.

MXU 2 (MXU 3) FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit by

subrackconfigura-

tion

Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 5  MXU ATM links in MXU 2 and MXU 3 (RNAC subrack 2) (Cont.)

Page 14: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 14/28

14 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in

unit

Slot Cabling

position

SW HW SW HW

0 MXU 0

MXU 1

9

(11)

B96 4V A2SU 0 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 0

MXU 1

9

(11)

B97 4W A2SU 1 AL2S-D 13 B76

(B77)

4A

(4B)

-

2 MXU 0

MXU 1

9

(11)

B98 4X - HDS-C

HDS-B

14 B 76

(B77)

4A

(4B)

1)5)

3 MXU 0

MXU 1

9

(11)

B99 4Y - HDS-B 15 B76

(B77)

4A

(4B)

5)

4 MXU 0

MXU 1

9

(11)

B100 4Z OMU 0 CCP1D-A

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 0

MXU 1

9

(11)

B101 5A RSMU 0 CCP1D-A

CCP18-C

CCP18-A

8 B76

(B77)

4A

(4B)

-

6 MXU 0

MXU 1

9

(11)

B102 5B ICSU CCP1D-A

CCP18-C

CCP18-A

7 B76

(B77)

4A

(4B)

-

7 MXU 0

MXU 1

9

(11)

B103 5C RNC-OMS MCP18-B 6 B76

(B77)

4A

(4B)

1)

8 MXU 0

MXU 1

9

(11)

B104 5D - ESA40-A

ESA24

5 B76

(B77)

4A

(4B)

1)

9 MXU 0

MXU 1

9

(11)

B105 5E DMCU 1 CDSP-DH 4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 0

MXU 1

9

(11)

B107 5G DMCU 0 CDSP-DH 3 B76

(B77)

4A

(4B)

-

11 MXU 0

MXU 1

9

(11)

B108 5H - - 2 B76

(B77)

4A

(4B)

3)

12 MXU 0

MXU 1

9

(11)

B109 5J SFU 0 SF10E

SF10

1 B76

(B77)

4A

(4B)

-

Table 6  MXU ATM links in MXU 0 and MXU 1 (RNAC subrack 1)

Page 15: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 15/28

DN0634547 15

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

13 MXU 0 9 B110 5K MXU 1 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 1 11 B110 5K MXU 0 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 0

MXU 1

9

(11)

B111 5L ICSU 0 CCP1D-A

CCP18-CCCP18-A

17 B76

(B77)

4A

(4B)

-

15 MXU 0

MXU 1

9

(11)

B112 5M ICSU 1 CCP1D-A

CCP18-C

CCP18-A

18 B76

(B77)

4A

(4B)

-

16 MXU 0

MXU 1

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

3)

17 MXU 0

MXU 1

9

(11)

B114 5O - - 13 B78

B79

4C

(4D)

3)

18 MXU 0

MXU 1

9

(11)

B115 5P A2SU 1 AL2S-D 12 B78

B79

4C

(4D)

4)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to

MXU 1. For instance, the SW cabling position B76 corresponds to MXU 0, whereas B77 in

brackets corresponds to MXU 1. The unit using the port, however, can connect via either MXU.

1) The tributary unit does not use the MXU port.

2) The MXU pair is cross-connected.

3) The MXU port is not in use.

4) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

5) HDS-B is two wide slot. HDS-C is one wide slot. When HDS-C slot is used, slot 15 is empty.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 6  MXU ATM links in MXU 0 and MXU 1 (RNAC subrack 1) (Cont.)

Page 16: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 16/28

16 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in unit Slot Cabling

position

SW HW SW HW

0 9

(11)

B96 4V A2SU 3 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 4

MXU 5

9

(11)

B97 4W DMCU 9 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 4

MXU 5

9

(11)

B98 4X DMCU 10 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 4

MXU 5

9

(11)

B99 4Y NIP1 0 NI16P1A 15 B76

(B77)

4A

(4B)

-

4 MXU 4

MXU 5

9

(11)

B100 4Z GTPU 1 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 4

MXU 5

9

(11)

B101 5A DMCU 8 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 4

MXU 5

9

(11)

B102 5B DMCU 7 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 4

MXU 5

9

(11)

B103 5C DMCU 6 CDSP-DH 6 B76

(B77)

4A

(4B)

-

8 MXU 4

MXU 5

9

(11)

B104 5D ICSU 6 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

9 MXU 4

MXU 5

9

(11)

B105 5E ICSU 5 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 4

MXU 5

9

(11)

B107 5G ICSU 4 CCP1D-A

CCP18-C

CCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 4

MXU 5

9

(11)

B108 5H DMCU 5 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 4

MXU 5

9

(11)

B109 5J DMCU 4 CDSP-DH 1 B76

(B77)

4A

(4B)

-

Table 7  MXU ATM links in MXU 4 and MXU 5 (RNAC subrack 3)

Page 17: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 17/28

DN0634547 17

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

13 MXU 4 9 B110 5K MXU 5 MX622-B/

MX622-C/

MX622-D

11 B121 5V 1)

MXU 5 11 B110 5K MXU 4 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 4

MXU 5

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

2)

15 MXU 4MXU 5

9(11)

B112 5M - - 18 B76(B77)

4A(4B)

2)

16 MXU 4

MXU 5

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

2)

17 MXU 4

MXU 5

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

2)

18 MXU 4

MXU 5

9

(11)

B115 5P A2SU 3 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 5. For

instance, the SW cabling position B76 corresponds to MXU 4, whereas B77 in brackets corresponds to MXU

5. The unit using the port, however, can connect via either MXU.1) The MXU pair is cross-connected.

2) The MXU port is not in use.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in unit Slot Cabling

position

SW HW SW HW

Table 7  MXU ATM links in MXU 4 and MXU 5 (RNAC subrack 3) (Cont.)

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

0 MXU 6

MXU 7

9

(11)

B96 4V A2SU 4 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 6

MXU 7

9

(11)

B97 4W DMCU 16 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 6

MXU 7

9

(11)

B98 4X DMCU 17 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 6

MXU 7

9

(11)

B99 4Y - - 15 B76

(B77)

4A

(4B)

-

Table 8  MXU ATM links in MXU 6 and MXU 7 (RNAC subrack 4)

Page 18: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 18/28

18 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

4 MXU 6

MXU 7

9

(11)

B100 4Z GTPU 2 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 6

MXU 7

9

(11)

B101 5A DMCU 15 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 6

MXU 7

9

(11)

B102 5B DMCU 14 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 6

MXU 7

9

(11)

B103 5C DMCU 13 CDSP-DH 6 B76

(B77)

4A

(4B)

-

8 MXU 6

MXU 7

9

(11)

B104 5D ICSU 9 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

9 MXU 6

MXU 7

9

(11)

B105 5E ICSU 8 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 6

MXU 7

9

(11)

B107 5G ICSU 7 CCP1D-A

CCP18-C

CCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 6

MXU 7

9

(11)

B108 5H DMCU 12 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 6

MXU 7

9

(11)

B109 5J DMCU 11 CDSP-DH 1 B76

(B77)

4A

(4B)

2)

13 MXU 6 9 B110 5K MXU 7 MX622-B/

MX622-C/

MX622-D

11 B121 5V 1)

MXU 7 11 B110 5K MXU 6 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 6

MXU 7

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

2)

15 MXU 6

MXU 7

9

(11)

B112 5M - - 18 B76

(B77)

4A

(4B)

2)

16 MXU 6

MXU 7

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

2)

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 8  MXU ATM links in MXU 6 and MXU 7 (RNAC subrack 4) (Cont.)

Page 19: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 19/28

DN0634547 19

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

17 MXU 6

MXU 7

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

2)

18 MXU 6

MXU 7

9

(11)

B115 5P A2SU 4 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 7. For

instance, the SW cabling position B76 corresponds to MXU 6, whereas B77 in brackets corresponds to MXU

7. The unit using the port, however, can connect via either MXU.

1) The MXU pair is cross-connected.

2) The MXU port is not in use.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 8  MXU ATM links in MXU 6 and MXU 7 (RNAC subrack 4) (Cont.)

MXU FU using the port Note

Port

no.

Mo. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

0 MXU 8

MXU 9

9

(11)

B96 4V A2SU 5 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 8

MXU 9

9

(11)

B97 4W DMCU 22 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 8

MXU 9

9

(11)

B98 4X DMCU 23 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 8

MXU 9

9

(11)

B99 4Y DMCU 24 CDSP-DH 15 B76

(B77)

4A

(4B)

-

4 MXU 8

MXU 9

9

(11)

B100 4Z GTPU 3 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 8

MXU 9

9

(11)

B101 5A DMCU 21 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 8

MXU 9

9

(11)

B102 5B DMCU 20 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 8

MXU 9

9

(11)

B103 5C DMCU 19 CDSP-DH 6 B76

(B77)

4A

(4B)

-

8 MXU 8

MXU 9

9

(11)

B104 5D ICSU 12 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

Table 9 MXU ATM links in MXU 8 and MXU 9 (RNBC subrack 1)

Page 20: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 20/28

20 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

9 MXU 8

MXU 9

9

(11)

B105 5E ICSU 11 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 8

MXU 9

9

(11)

B107 5G ICSU 10 CCP1D-A

CCP18-C

CCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 8

MXU 9

9

(11)

B108 5H DMCU 18 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 8

MXU 9

9

(11)

B109 5J - - 1 B76

(B77)

4A

(4B)

1)

13 MXU 8 9 B110 5K MXU 9 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 9 11 B110 5K MXU 8 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 8

MXU 9

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

1)

15 MXU 8

MXU 9

9

(11)

B112 5M - - 18 B76

(B77)

4A

(4B)

1)

16 MXU 8

MXU 9

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

1)

17 MXU 8

MXU 9

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

1)

18 MXU 8

MXU 9

9

(11)

B115 5P A2SU 5 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 9. Forinstance, the SW cabling position B76 corresponds to MXU 8, whereas B77 in brackets corresponds to MXU

9. The unit using the port, however, can connect via either MXU.

1) The MXU port is not in use.

2) The MXU pair is cross-connected.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

Mo. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 9 MXU ATM links in MXU 8 and MXU 9 (RNBC subrack 1) (Cont.)

Page 21: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 21/28

DN0634547 21

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in unit Slot Cabling

position

SW HW SW HW

0 MXU 10

MXU 11

9

(11)

B96 4V A2SU 6 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 10

MXU 11

9

(11)

B97 4W DMCU 28 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 10

MXU 11

9

(11)

B98 4X DMCU 29 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 10

MXU 11

9

(11)

B99 4Y GTPU 4 CCP1D-A

CCP18-C

CCP18-A

15 B76

(B77)

4A

(4B)

-

4 MXU 10

MXU 11

9

(11)

B100 4Z GTPU 5 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 10

MXU 11

9

(11)

B101 5A DMCU 27 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 10

MXU 11

9

(11)

B102 5B DMCU 26 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 10

MXU 11

9

(11)

B103 5C - - 6 B76

(B77)

4A

(4B)

1)

8 MXU 10

MXU 11

9

(11)

B104 5D ICSU 15 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

9 MXU 10

MXU 11

9

(11)

B105 5E ICSU 14 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 10

MXU 11

9

(11)

B107 5G ICSU 13 CCP1D-A

CCP18-CCCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 10

MXU 11

9

(11)

B108 5H DMCU 25 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 10

MXU 11

9

(11)

B109 5J - - 1 B76

(B77)

4A

(4B)

1)

Table 10  MXU ATM links in MXU 10 and MXU 11 (RNBC subrack 2)

Page 22: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 22/28

22 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

13 MXU 10 9 B110 5K MXU 11 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 11 11 B110 5K MXU 10 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 10

MXU 11

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

1)

15 MXU 10MXU 11

9(11)

B112 5M - - 18 B76(B77)

4A(4B)

1)

16 MXU 10

MXU 11

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

1)

17 MXU 10

MXU 11

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

1)

18 MXU 10

MXU 11

9

(11)

B115 5P A2SU 6 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 11. For

instance, the SW cabling position B76 corresponds to MXU 10, whereas B77 in brackets corresponds to

MXU 11. The unit using the port, however, can connect via either MXU.1) The MXU port is not in use.

2) The MXU pair is cross-connected.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in unit Slot Cabling

position

SW HW SW HW

Table 10  MXU ATM links in MXU 10 and MXU 11 (RNBC subrack 2) (Cont.)

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

0 MXU 12

MXU 13

9

(11)

B96 4V A2SU 7 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 12

MXU 13

9

(11)

B97 4W DMCU 34 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 12

MXU 13

9

(11)

B98 4X DMCU 35 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 12

MXU 13

9

(11)

B99 4Y DMCU 36 CDSP-DH 15 B76

(B77)

4A

(4B)

-

Table 11 MXU ATM links in MXU 12 and MXU 13 (RNBC subrack 3)

Page 23: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 23/28

DN0634547 23

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

4 MXU 12

MXU 13

9

(11)

B100 4Z GTPU 6 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 12

MXU 13

9

(11)

B101 5A DMCU 33 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 12

MXU 13

9

(11)

B102 5B DMCU 32 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 12

MXU 13

9

(11)

B103 5C DMCU 31 CDSP-DH 6 B76

(B77)

4A

(4B)

-

8 MXU 12

MXU 13

9

(11)

B104 5D ICSU 18 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

9 MXU 12

MXU 13

9

(11)

B105 5E ICSU 17 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 12

MXU 13

9

(11)

B107 5G ICSU 16 CCP1D-A

CCP18-C

CCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 12

MXU 13

9

(11)

B108 5H DMCU 30 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 12

MXU 13

9

(11)

B109 5J - - 1 B76

(B77)

4A

(4B)

1)

13 MXU 12 9 B110 5K MXU 13 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 13 11 B110 5K MXU 12 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 12

MXU 13

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

1)

15 MXU 12

MXU 13

9

(11)

B112 5M - - 18 B76

(B77)

4A

(4B)

1)

16 MXU 12

MXU 13

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

1)

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 11 MXU ATM links in MXU 12 and MXU 13 (RNBC subrack 3) (Cont.)

Page 24: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 24/28

24 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8d

Confidential

Use of MXU ATM links

17 MXU 12

MXU 13

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

1)

18 MXU 12

MXU 13

9

(11)

B115 5P A2SU 7 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 13.

For instance, the SW cabling position B76 corresponds to MXU 12, whereas B77 in brackets corre-

sponds to MXU 13. The unit using the port, however, can connect via either MXU.

1) The MXU port is not in use.

2) The MXU pair is cross-connected.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary unit Plug-in

unit

Slot Cabling

position

SW HW SW HW

Table 11 MXU ATM links in MXU 12 and MXU 13 (RNBC subrack 3) (Cont.)

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in unit Slot Cabling

position

SW HW SW HW

0 MXU 14

MXU 15

9

(11)

B96 4V A2SU 8 AL2S-D 12 B76

(B77)

4A

(4B)

-

1 MXU 14

MXU 15

9

(11)

B97 4W DMCU 41 CDSP-DH 13 B76

(B77)

4A

(4B)

-

2 MXU 14

MXU 15

9

(11)

B98 4X DMCU 42 CDSP-DH 14 B76

(B77)

4A

(4B)

-

3 MXU 14

MXU 15

9

(11)

B99 4Y DMCU 43 CDSP-DH 15 B76

(B77)

4A

(4B)

-

4 MXU 14

MXU 15

9

(11)

B100 4Z GTPU 7 CCP1D-A

CCP18-C

CCP18-A

16 B76

(B77)

4A

(4B)

-

5 MXU 14

MXU 15

9

(11)

B101 5A DMCU 40 CDSP-DH 8 B76

(B77)

4A

(4B)

-

6 MXU 14

MXU 15

9

(11)

B102 5B DMCU 39 CDSP-DH 7 B76

(B77)

4A

(4B)

-

7 MXU 14

MXU 15

9

(11)

B103 5C DMCU 38 CDSP-DH 6 B76

(B77)

4A

(4B)

-

8 MXU 14

MXU 15

9

(11)

B104 5D ICSU 21 CCP1D-A

CCP18-C

CCP18-A

5 B76

(B77)

4A

(4B)

-

Table 12  MXU ATN links in MXU 14 and MXU 15 (RNBC subrack 4)

Page 25: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 25/28

DN0634547 25

 ATM links and LAN connections in RNC450 Use of MXU ATM links

Id:0900d805808e1b8d

Confidential

9 MXU 14

MXU 15

9

(11)

B105 5E ICSU 20 CCP1D-A

CCP18-C

CCP18-A

4 B76

(B77)

4A

(4B)

-

- - - 5F - - - - 5F -

10 MXU 14

MXU 15

9

(11)

B107 5G ICSU 19 CCP1D-A

CCP18-C

CCP18-A

3 B76

(B77)

4A

(4B)

-

11 MXU 14

MXU 15

9

(11)

B108 5H DMCU 37 CDSP-DH 2 B76

(B77)

4A

(4B)

-

12 MXU 14

MXU 15

9

(11)

B109 5J - - 1 B76

(B77)

4A

(4B)

1)

13 MXU 14 9 B110 5K MXU 15 MX622-B/

MX622-C/

MX622-D

11 B121 5V 2)

MXU 15 11 B110 5K MXU 14 MX622-B/

MX622-C/

MX622-D

9 B121 5V

14 MXU 14

MXU 15

9

(11)

B111 5L - - 17 B76

(B77)

4A

(4B)

1)

15 MXU 14

MXU 15

9

(11)

B112 5M - - 18 B76

(B77)

4A

(4B)

1)

16 MXU 14

MXU 15

9

(11)

B113 5N - - 14 B78

(B79)

4C

(4D)

1)

17 MXU 14

MXU 15

9

(11)

B114 5O - - 13 B78

(B79)

4C

(4D)

1)

18 MXU 14

MXU 15

9

(11)

B115 5P A2SU 8 AL2S-D 12 B78

(B79)

4C

(4D)

3)

Values indicated in the table in brackets correspond to the MXU in brackets, in other words, to MXU 15. Forinstance, the SW cabling position B76 corresponds to MXU 14, whereas B77 in brackets corresponds to

MXU 15. The unit using the port, however, can connect via either MXU.

1) The MXU port is not in use.

2) The MXU pair is cross-connected.

3) The second MXU port for A2SU unit is reserved for future use. Not in use in this release.

MXU FU using the port Note

Port

no.

No. Slot Cabling

position

Tributary

unit

Plug-in unit Slot Cabling

position

SW HW SW HW

Table 12  MXU ATN links in MXU 14 and MXU 15 (RNBC subrack 4) (Cont.)

Page 26: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 26/28

26 DN0634547

 ATM links and LAN connections in RNC450

Id:0900d805808e1b8f 

Confidential

LAN connections

4 LAN connectionsThis chapter provides lists of the LAN connections in ESA40-A/ESA24 in RNC450.

Note that the alternatives for different SW and HW cabling positions are shown in brack-ets, for example, B76 and B80 are alternative SW cabling positions.

ESA40-A 0 (ESA40-A 1)

 / ESA24 0 (ESA24 1)

LAN using the port Note

Port no. Slot Cabling position FU Plug-in unit /

panel

Slot Cabling

position

SW HW SW HW

1/1/1 1.5

(2.5)

- ETH1 - - - - - 1)

1/1/2 1.5(2.5)

- ETH2 - - - - - 1)

1/1/3 1.5

(2.5)

B78 4C OMU 0 CCP1D-A

CCP18-A

1.16 B52

(B54)

3B

(3D)

-

1/1/4 1.5

(2.5)

B80 4E OMU 1 CCP1D-A

CCP18-A

2.16 B52

(B54)

3B

(3D)

-

1/1/6 1.5

(2.5)

B84 4J SWU 0 ESA40-A

/ESA24

2.5 B84 4J 4)

1/1/7 1.5

(2.5)

B90 4P RSMU 0 CCP1D-A

CCP18-C

CCP18-A

- - - 5)

1/1/8 1.5

(2.5)

B92 4R RSMU 1 CCP1D-A

CCP18-C

CCP18-A

- - - 5)

1/1/9 1.5

(2.5)

- 4T NPGE(P) 0 NP2GE-B 3.15 - 4E

(4G)

-

1/1/10 1.5

(2.5)

- 4V NPGE(P) 1 NP2GE-B 4.15 - 4E

(4G)

-

1/1/15 1.5

(2.5)

- 5F NPGE(P) 6 NP2GE-B 3.17 - 4E

(4G)

-

1/1/16 1.5

(2.5)

- 5H NPGE(P) 7 NP2GE-B 4.17 - 4E

(4G)

-

1/1/24 1.5

(2.5)

B124 5Y - CPSY-A - - ETH -

Table 13 LAN port use of ESA40-A/ESA24 (RNAC, with ESA40-A 0/ESA24 0 in subrack 1 and ESA40-A

1/ESA24 1 in subrack 2)

Page 27: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 27/28

DN0634547 27

 ATM links and LAN connections in RNC450 LAN connections

Id:0900d805808e1b8f 

Confidential

1/1/39 1.5

(2.5)

- ETH3 - - - - - 1) 6)

1/1/40 1.5

(2.5)

- ETH4 - - - - - 1) 6)

1.5

(2.5)

1S - ADMOD01 2)

1.5

(2.5)

1U - ADMOD01 3)

Values indicated in the table in brackets correspond to the ESA40-A/ESA24 in brackets, in other words, to

ESA40-A 1/ESA24 1. For instance, the HW cabling position 00 corresponds to ESA40-A 0, whereas 02 in

brackets corresponds to ESA40-A 1. The unit using the port, however, can connect via either ESA40-

 A/ESA24.

1) Cabling out of the network element.

2) Cabinet address setting module

3) Subrack address setting module

4) Redundancy cable is not attached at the factory

5) LAN for RRMU was moved to RSMU.

6) Port 39 and 40 is used for ESA40-A only.

ESA40-A 0 (ESA40-A 1)

 / ESA24 0 (ESA24 1)

LAN using the port Note

Port no. Slot Cabling position FU Plug-in unit /

panel

Slot Cabling

position

SW HW SW HW

Table 13 LAN port use of ESA40-A/ESA24 (RNAC, with ESA40-A 0/ESA24 0 in subrack 1 and ESA40-A

1/ESA24 1 in subrack 2) (Cont.)

ESA40-A 0 (ESA40-A 1)

ESA24 0 (ESA24 1)

LAN using the port Note

Port no. Slot Cabling position FU Plug-in unit /

panel

Slot Cabling

position

SW HW SW HW

1/1/11 1.5

(2.5)

- 4X NPGE(P) 2 NP2GE-B 1.1 - 4E

(4G)

-

1/1/12 1.5

(2.5)

- 4Z NPGE(P) 3 NP2GE-B 2.1 - 4E

(4G)

-

1/1/13 1.5

(2.5)

- 5B NPGE(P) 4 NP2GE-B 3.1 - 4E

(4G)

-

1/1/14 1.5

(2.5)

- 5D NPGE(P) 5 NP2GE-B 4.1 - 4E

(4G)

-

Table 14 LAN port use of ESA40-A/ESA24 (RNBC, with ESA40-A 0/ESA24 0 in RNAC subrack 1 and ESA40-

 A 1/ESA 24 1 in RNAC subrack 2)

Page 28: atm_links_rnc450_DN0634547_03A_en.pdf

8/9/2019 atm_links_rnc450_DN0634547_03A_en.pdf

http://slidepdf.com/reader/full/atmlinksrnc450dn063454703aenpdf 28/28

 ATM links and LAN connections in RNC450LAN connections

Values indicated in the table in brackets correspond to the ESA40-A/ESA24 in brackets, in other words, to

ESA40-A/ESA24 1. For instance, the HW cabling position 00 corresponds to ESA40-A 0, whereas 02 in

brackets corresponds to ESA40-A 1. The unit using the port, however, can connect via either ESA40-

 A/ESA24.

ESA40-A 0 (ESA40-A 1)

ESA24 0 (ESA24 1)

LAN using the port Note

Port no. Slot Cabling position FU Plug-in unit /

panel

Slot Cabling

position

SW HW SW HW

Table 14 LAN port use of ESA40-A/ESA24 (RNBC, with ESA40-A 0/ESA24 0 in RNAC subrack 1 and ESA40-

 A 1/ESA 24 1 in RNAC subrack 2) (Cont.)