ATM-monitoring systems

Universal 1 to 16-channel monitoring systems

ATM-features

Characteristics and specifications of ATM

ATM-input modules

ATM-sensors and accessories

Possible connections for the ATM

ATM-accessories

Wireless sensors for the ATM

Page 2: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Thank you for your interest in the ATAL monitoring-and data recording instrumentation.

For over 18 years ATAL B.V. is the specialist supplier/manu-facturer of data recorders, portable meters, monitoring systems and high-quality sensors. The product range also includes powerful analysis software. The instruments provide insight into critical processes and hence make them manageable. Our instrumentation is used in various specialist fields of applications. Typical examples of applications are indoor air-quality surveys, monitoring jobs in hospitals, process- & food industry. Moreover, the ATAL instrumentation is often used for energy-audits or for measurement and control purposes in building management or in cooling technology.

With the instruments covered in this catalogue, we are able to monitor over 40 different parameters. Our product range includes compact lightweight single-channel and multi-channel data recorders, multi-channel monitoring systems with alarming features, sensors and portable measurement instruments.

Many of the end-user’s requirements which have reached us from the market over the past, concerning hardware specifications and software features are met in the up-dated product series that are presented in this catalogue. In this respect we would like to point at the new series of wireless sensors for the ATM-monitoring systems, the range of sensors with Ethernet connectivity and the Venti-Light CO

2-sensors/controllers with 3-colour LED-

indication.

If you might have difficulties to select the instrument or recorder that meets your specific requirements, please do not hesitate to contact us or your distributor for further assistance.

ATAL B.V.

P.O. Box 783NL-1440 AT Purmerend

Calibration service

We would be pleased to assist you to the best of our abili-ties as we are in business to solve your monitoring needs!

The ATAL Sales & Service-team

ATAL provides high-quality, high value for money calibration and equipment support service. This service is also available for non-ATAL instrumentation (third party equipment). All calibrations are traceable compliant with the international requirements such as NEN-EN ISO/IEC 17025 including an “as found” test data report for out of tolerance instrument conditions. The calibrations usually take a 5 day laboratory turnaround time for scheduled items. If desired by the end-user, ATAL can provide an automatic recall notice for equipment approaching its calibration due date provided 30 days prior to calibration due dates.

Visit our website www.atal.nl

Full coverage of all instruments Ñ

Live demo’s Ñ

Additional product literature Ñ

Up-to-date product information Ñ

24/7 webshop Ñ

Phone: +31-(0)299-630610Fax: +31-(0)299-630611

E-mail: [email protected]: www.atal.nl

Data Recording Specialists2

Introduction

u

u

u

u

u

Page 3: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

3

Index

Index

Introduction 2

Index 3

Universal 1 to 16 channel monitoring systems 4

Characteristics ATM monitoring systems 6

ATM monitoring systems, models 8

ATM monitoring systems, specifications 9

ATM-055D input modules 10

ATM-06D user programmable free inputs 11

Analysis software 12

ATAL data base software 14

Possible connections for the ATM monitoring systems 15

Sensors and accessories ATM monitoring systems 16

Wireless sensors for the ATM monitoring systems 17

Accessories for ATM monitoring systems 18-19

Page 4: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists44 Data Recording Specialists

Universal 1 to 16-channel monitoring systems

ATM-systems

u

u

u

u

u

u

u

The ATAL ATM-monitoring systems are stand-alone modu-lar 1- to 16-channel data recorders that can be configured entirely to meet your monitoring needs. The ATM-05D has 16 free input slots and can be extended via input modules. There is a choice from 34 different input modules, optical or non-optical isolated. The ATM-06D offers 16 universal input channels which can be defined through the ATM-software. The systems have been developed for stand-

alone recording of such parameters as temperature (via Pt100, Pt1000, Ni1000 sensors and thermocouples), DC process signals (mA, Volt) and pulses (status or counting). The simple installation and the exceptionally user-friendly software are distinguishing features of the ATM-systems, which have a number of standard and unique characte-ristics that will provide you with maximum ease of use. Automatic data transferral, network possibilities, trigger possibilities, GSM or other modem communication, real time graphics display and exchangeable input modules are standard provisions!

Data storageThe monitoring systems have a large memory capable for storage of 480,000 readings and can function inde-pendently without a PC. The sample interval for taking readings data can be set for each channel independently, varying from 1x per second to 1x per 24 hours. It is also possible to save data on the hard disk of a PC or laptop while monitoring. The ATM-must be coupled to a PC via the RS232 port, the RS485 port, the USB port, an Ethernet connection or a modem in order to do this. All recorded data can be analysed easily and if required made ready for use in reports by means of the Windows® analysis software supplied with the system.

ATM-055D: any configuration possible from 1 to 16 inputs, a choice of 34 input modulesATM-06D: 16 universal inputs, user programmable through the softwareAny configurations possible from 1 to 16 inputs and a choice of 34 input modulesMemory for 480,000 readings, automatic download to a PC possibleHigh system accuracy due to 16 bits analogue/digital converterEasy installation and configuration; the system is near enough “plug & play” Various alarm outputs: acoustic, optical, SMS and via relay outputs

Features:

Page 5: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

5

ATM

Food industry and supermarkets Recording and monitoring criti-

cal temperatures required by the

HACCP regulations

Process industryRecording of such parameters as

pulse signals, pressures, tempera-

tures, voltages and currents.

Cooling and freezing technologyRecording and monitoring tem-

peratures and pressures

Building and energy managementRecording of comfort parameters

(including temperature, %RH, car-

bon dioxide (CO2) and air velocity),

control of air conditioning units,

recording energy consumption.

Research & DevelopmentRecording and monitoring of

processes, recording of various

parameters in test equipment.

Laboratories and pharmacies Recording of temperatures, carbon

dioxide (CO2) and other critical

parameters required for the GLP or

GMP regulations.

Applications

ATM-055D

ATM

Indicator to show when operating

Indicator to show use of memory

Alarm indicator per channel

Dual LCD display showing channel name and actual reading

The ATM-units can be used for a wide variety of applications, both in a clean and a polluted industrial environment. They can even be used in the open air if they are fitted with the optional splash-proof housing. An overview of a number of com-mon applications is shown below.

Control of critical water temperatureRecording and monitoring tempera-

ture of critical water temperatures in

the pipe network.

HorticultureRecording of temperature, rela-

tive humidity and carbon

dioxide (CO2), monitoring

energy consumption.

Touch pad menu control for the display

Communication interfaces

RS-232/485(standard)

USB(standard)

Ethernet(optionall)

GSM(optional)

Page 6: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists6

ATM

ATM-features

Recording

Trigger input for external starting and stopping For certain applications it is useful to start and stop the recording by means of an external contact, in order that the memory of the ATM-unit is used as efficiently as possible. A digital input can be linked to any of the ATM-inputs to func-tion as a “start/stop” input. As soon as contact is made in the digital input, the recording can be started or stopped.

It is also possible to activate a different sample interval if a digital input changes status (for example, in the event of a failure, it may be desirable to collect more readings).

Information on the LCD displayThe ATM-05D and ATM-06D unit has an LCD screen on which the actual readings of the various inputs are displayed. Func-tion keys can be used to display all values one by one. There are also four LEDs to show the status of the mains voltage and the memory. An acoustic signal is also given when these status indicators are activated.

Recording with confidenceIf there is a power failure the recorder will stop collecting data. Up till the moment of the power failure the date and time of the failure as well as the readings taken will be stored in a back-up battery. After the power has been restored the ATM units will automatically resume recording.

Every channel its own label16 process labels or names can be created per system that can be linked to a specific channel during the course of the process. An operator can select the desired label using the ATM-function keys. The label selected is recorded as well as the actual reading.

Wireless sensorsYou can make significant savings on your installation costs by using wireless sensors! No more cables, no more need to pen-etrate walls or insulation materials. The ATM-monitoring unit can be supplied with an external receiver suitable for receiving the radio signal from 1 to 16 wire-less sensors. The sensors work on the 868 MHz frequency band and have a maximum range of 400m in the field. Wireless sensors are available for monitoring temperature, relative hu-midity, carbon dioxide, current, Volt-age and energy consumption. More information about these sensors can be found on page 17 or in the ATAL Sensor Catalogue.

Page 7: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

7

ATM

u

u

u

u

u

Alarms & Communication

Multiple ATM-systems linked via RS485 or Ethernet connectionIf 16 channels of one ATM-system are not sufficient for a particular monitoring project, a RS485 or Ethernet network can be used to link multiple ATM-systems together. Each ATM-unit is then allocated an unique RS485 or IP address. In the case of a RS485 network an RS232/485 converter must be installed on the main PC. The maximum distance accessible using RS485 is 1 km.

Alarm functions The ATM-units have extensive facilities for reporting alarms. Four limiting conditions can be set independently in each channel, including the hysteresis and rise and fall delay if required. An alarm is given both acoustically (buzzer) and visually (LED 1 to 32). The ATM-units have relay contacts for sending the alarm through to a central alarm system or for operating a telephone dialer. The four alarm conditions per channel are particularly flexible in combination with the optional external relay module (item ATM-AC01). For example, two conditions can be used to operate the relay outputs and two for reporting the alarm status by SMS.

Communication via analogue or GSM modem Both an analogue and a GSM modem can be used for remote communication with an ATM-unit. All functions, such as setting, reading and even displaying readings in real time can be made with the help of modem communication. The GSM modem has the advantage that there is no need for a permanent telephone line. The analogue modem has as advantage that the communi-cation is faster (56k6). The modems supplied by ATAL have been exten-sively tested in practice so that you are guaranteed maximum certainty of operation.

Alarms by means of:

GSM modem E-mail notification SMS message Automatic telephone dialer Buzzer (local)

Alarms via SMS messageAll ATM-systems can be provided with an RS232 “SMS port” to which an ATAL ap-proved GSM modem can be connected for reporting alarms via SMS messages. The ATM-unit can report to any 4 cell phone numbers that have been entered in the system. A PC that can be used independently for the “SMS port” can be linked to the RS232, RS485, USB or Ether-net port of the ATM-system.It is also possible to make remote contact with the ATM-unit in order to change settings, to view realtime readings in real time and to retrieve data that has been stored.

GSM & SMS communication

Access actual readings via SMS messagesThe system operator can send a SMS mes-sage “INFO” to a remote ATM-system and then receive an SMS message back with all the actual measurement data with the alarm and system status. In order to do this, the ATM-system must be connected to an ATAL approved GSM modem that supports SMS messages.

Page 8: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists8

ATM

ATM-monitoring systems, models

Important differences ATM-055(D) ATM-06D

Inputs: 1 to 16modular configuration

16multipurpose programmable

Max. measurable value DC current: 5 A dc 20 mA dc

Max. measurable value DC voltage: 75 V dc 10 V dc

Most sensitive input range DC voltage:

100 mV dc 18 mV dc

Max. measurable value AC voltage:

50 V ac n/a

Max. measurable value AC current:

5 A ac n/a

Frequency measurement: 0 to 5 kHz n/a

Pulse counting (e.g. for energy meters)

Yes n/a

Possibility to use optical isolated inputs:

Yes RS485 input is optical isolated. Analogue inputs are not optical isolated.

Available as 19" rack model: No Yes, model ATM-06DR

ATM-055D

With LCD display

Top view (system connections)

Rear view (sensor connections)

Standard RS232, RS484 and USB. Ethernet is optional.

ATM-06DR 19” rack version

ATM-06D

With LCD display

ATM-06DT Desktop version

ATM-055(D)

The desired configuration is obtained by using from 1 to 16 of the input modules for insertion in the ATM-055(D). A choice can be made from the more than 30 different input modules (see the listing on page 10).

New: Virtual (calculated) channels

ATM-06D

The ATM-06D series has 16 multipurpose programmable inputs. A choice can be made from a limited number of possibilities (see the listing on page 11).

New: Virtual (calculated) channels

Top view (system connections)

Rear view (sensor connections)

Standard RS232, RS484 and USB. Ethernet is optional.

Page 9: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

9

ATMATM

ATM-055D ATM-06D

AATM-05D

Inputs: 1-16configure using input modules

1-16 multipurpose user programmable (through software)

Data recording: Yes Yes

LCD display and 4-button operating: Yes Yes

Communication interfaces, standard provisions: (for coupling to the PC)

All ATM models are fitted standard with:- RS232 connection (for direct coupling to the PC or via (GSM) modem- USB connection- RS485 network interface (if a protected cable is used a max. distance of 1200 m can be bridged)

Communication interface, optional:

ATM models can be supplied with the option of:- Ethernet (LAN), communication via SNMP, SOAP and via a web browser

SMS/Data communication port: Standard Standard

Communication speed: 9,600, 19,200, 57,600, 115,100 and 230,400 Baud

System requirements: ATM software is compatible with Windows® XP and more recent Windows® versions

Visual alarm: LED indicator to show alarm status, 2 LEDs per channel

LED indicator to show alarm status, 2 LEDs per channel

External alarm (relay): 1 (230VAC/8A) 1 (230VAC/8A)

External alarm (voltage): All ATM models have voltage output 0V/4.8V (max. 50 mA) to operate an external buzzer or external automatic telephone caller, see Accessories pages 18/19

External alarm, optional: All ATM models can be extended with a 16-channel external relay module (order code ATM-05-AC01), see Accessories pages 18/19

Dimensions (w x h x d): 215x225x60 mm 215x225x44 mm

Weight: about 1150 g about 1150 g

Watertight housing: Optional Optional

Various models of the ATM monitoring systems are available. The main differences between the systems are specified in the table below. Input modules are used to configure the ATM-055D series to suit the monitoring needs of the user (there is a choice from 34 different modules).

The new ATM-06D series has 16 multipurpose user programmable inputs.

Models

ATM-monitoring systems, specifications

General specifications

Material of housing: Metal

Operating conditions: 0 to 50 oC

Clock: Real time clock

A/D conversion: 16 bits resolution

Interval time: Can be set separately for each channel in steps from 1 sec to 24 hours

Capacity of memory: Standard 2 MB (480,000 analogue readings)

Registration method: “Stop if full” or “First-in - first-out”

Protection class: IP2x

Connector: Standard Wago plug-in connector (removable)ATM-055D: 3 connections available per channel (in, com, protection)ATM-06D: 4 connections available per channel (24V/25mA max. out, in, com, protection)

LED indicators: –To show power–To show alarm limiting values exceeded (several levels per input)–To show set memory percentage exceeded

Power supply: 9-30 Vdc (24Vdc recommended)

Page 10: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists10

ATM

ATM-input modules

Code Type Bereik Opmerking Max. resolutie

ATM-A0 DC-stroom 4-20mA loop wordt door module gevoed 0,001 mA

ATM-A1 DC-stroom 4-20mA loop dient extern te worden gevoed 0,001 mA

ATM-B0 DC-stroom 0-20mA — 0,001 mA

ATM-B1 DC-stroom 0-1A — 0,0001 A

ATM-B2 DC-stroom 0-5A — 0,001 A

ATM-C0 AC-stroom 0-20mA galvanisch gescheiden 0,001 mA

ATM-C1 AC-stroom 0-1A galvanisch gescheiden 0,0001 A

ATM-C2 AC-stroom 0-5A galvanisch gescheiden 0,001 A

ATM-D0 DC-spanning 0-100mV — 0,0001 V

ATM-D1 DC-spanning 0-1V — 0,0001 V

ATM-D2 DC-spanning 0-10V — 0,001 V

ATM-D4 DC-spanning 0-75V — 0,01 V

ATM-D5 DC spanning -10V tot +10V galvanisch gescheiden 0,001V

ATM-E0 AC-spanning 0-100mV galvanisch gescheiden 0,01 mV

ATM-E1 AC-spanning 0-1V galvanisch gescheiden 0,0001 V

ATM-E2 AC-spanning 0-10V galvanisch gescheiden 0,001 V

ATM-E4 AC-spanning 0-50V galvanisch gescheiden 0,001 V

ATM-F weerstand 2-draads bereik vooraf specificeren

ATM-J RTD Ni1000 2-draads bereik –50 tot +250 °C 0,01 °C

ATM-Z13 RTD Pt1000 2-draads bereik –10 tot +50 °C 0,1 °C

ATM-K RTD Pt100 2-draads bereik –140 tot +600 °C 0,1 °C

ATM-K1 RTD Pt1000 2-draads bereik –140 tot +600 °C 0,1 °C

ATM-K3 RTD Pt1000 2-draads bereik -10 tot +50°C (nauwkeurigheid +/-0,06C)

0,01 °C

ATM-N thermokoppel K bereik –70 tot 1300 °C 0,1 °C

ATM-O thermokoppel J bereik –200 tot 750 °C 0,1 °C

ATM-P thermokoppel S bereik 0 tot 1700 °C 0,1 °C

ATM-Q thermokoppel B bereik +100 tot +1800 °C 0,1 °C

ATM-FU frequency 0-5 kHz On status 3 to 24 vdc optical isolated min. pulse length 30 μs

1 Hz

ATM-FK frequency 0-5 kHz potential free contacts min. pulse length 30 μs

1 Hz

Code Type Range Remarks Max. resolution

ATM-A0 DC-current 4-20mA loop powered by module 0,001 mA

ATM-A1 DC-current 4-20mA loop must be powered externally 0,001 mA

ATM-B0 DC-current 0-20mA — 0,001 mA

ATM-B1 DC-current 0-1A — 0,0001 A

ATM-B2 DC-current 0-5A — 0,001 A

ATM-C0 AC-current 0-20mA optical isolated 0,001 mA

ATM-C1 AC-current 0-1A optical isolated 0,0001 A

ATM-C2 AC-current 0-5A optical isolated 0,001 A

ATM-D0 DC-voltage 0-100mV — 0,0001 V

ATM-D1 DC-voltage 0-1V — 0,0001 V

ATM-D2 DC-voltage 0-10V — 0,001 V

ATM-D4 DC-voltage 0-75V — 0,01 V

ATM-D5 DC voltage -10V to +10V optical isolated 0,001V

ATM-E0 AC-voltage 0-100mV optical isolated 0,01 mV

ATM-E1 AC-voltage 0-1V optical isolated 0,0001 V

ATM-E2 AC-voltage 0-10V optical isolated 0,001 V

ATM-E4 AC-voltage 0-50V optical isolated 0,001 V

ATM-F resistance 2-wires range to be specified in advance

ATM-J RTD Ni1000 2-wires range -50 to +250 °C 0,01 °C

ATM-K RTD Pt100 2-wires range -140 to +600 °C 0,1 °C

ATM-K1 RTD Pt1000 2-wires range -140 to +600 °C 0,1 °C

ATM-K3 RTD Pt1000 2-wires range -10 to +50°C (accuracy +/-0,06C)

0,01 °C

ATM-N thermocouple K range -70 to 1300 °C 0,1 °C

ATM-O thermocouple J range -200 to 750 °C 0,1 °C

ATM-P thermocouple S range 0 to 1700 °C 0,1 °C

ATM-Q thermocouple B range +100 to +1800 °C 0,1 °C

ATM-S digitaal contacts non-optical isolated —

ATM-SG digital contacts optical isolated —

ATM-S1 digital voltage

ON status: 3 to 30 Vss optical isolated

ATM-CTU counter voltage ON-status: 3 to 30 Vss optical isolated max. puls frequency 5 kHz with back-up battery

ATM-CTK counter contacts non-optical isolated max. pulse frequency 5 kHz with back-up battery

ATM-RS RS485 ADAM protocol for transmitters with RS485 outputoptical isolated. Can also be used with ATAL wireless sensors

ATM-RP RS485 Modbus protocol for sensors with RS485 output that communicate via Modbus

The basic ATM-055D system is manufactured standard with 16 free input slots for connecting any type of input module. The modular system configuration gives you the flexibility to start with just a few input modules and to extend and/or to change the system later up to a maximum of 16 input modules per ATM-055D system. If desired ATAL can carry out this reconfiguration for you.

The modules A1 / B0 / B1 / B2 / D0 / D1 / D2 / D4 / D5 / F / J / K / K1 / N / T / O / P / Q and S are not optical isolated. As an option these modules can be supplied as optical isolated input modules. The letter “G” must then be included after the article code when ordering the particular module (e.g. the optical isolated input module for 0-10VDC signals has article code ATM-D2G). Due to the special construction of the thermocouple channels it is not possible to add a thermocouple module at a later time.

Available input modules:

Page 11: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

11

ATMATM-06D User programmable free inputs

The ATM-06D data logger is fitted standard with 16 multipurpose inputs for free programming. Every possible combination can be made on the basis of the input types with corresponding measurement range shown below. In short, this is a very versatile recorder with exceptional ease of use and optimum flexibility. An RS485 input is available as an optional extra allowing readings from sensors that communicate using the Modbus protocol to be input and then registered.

Type and range Accuracy Notes

DC current4 to 20 mA

± 0,1 full scale(± 0,02 mA)

suitable for active sensors (terminals COM and GND) or for passive sensors (terminals +24V and COM)

DC voltage-10V to + 10V

± 0,1% full scale (± 10 mV)

input impedance ± 10 MOhms, terminals IN and COM

DC voltage-1V to + 1V

± 0,1% full scale (± 1 mV)

input impedance ± 10 MOhms, terminals IN and COM

DC voltage-100mV to + 100mV

± 0,1% full scale (± 100 µV)

input impedance ± 10 MOhms, terminals IN and COM

DC voltage-18mV to + 18mV

± 0,1% full scale (± 18 µV)

input impedance ± 10 MOhms, terminals IN and COM

Thermocouple K (NiCr-Ni)-200 to +1300oC

± 0,3% of measured value + 1,5oC

linearized, cold weld compensation terminals IN and COM

Thermocouple J (Fe-Co) -200 to +750oC

± 0,3% of measured value + 1,5oC

linearized, cold weld compensation terminals IN and COM

Thermocouple S (Pt10%Rh-Pt)0 to +1700oC

± 0,3% of measured value + 1,0oC

linearized, cold weld compensation terminals IN and COM

Thermocouple B (Pt30%Rh-Pt)+100 to +1800oC

± 0,3% of measured value + 1,5oC

linearized, without cold weld compensation termi-nals IN and COM

Thermocouple T (Cu-CuNi) -200 to +400oC

± 0,3% of measured value + 1,5oC

linearized, without cold weld compensation termi-nals IN and COM

Platinum temperature sensor Pt100 -200 to +600oC

± 0,2oC from -200 to +100oC ± 0,2% of measured value from +100 to +600oC

2-wire connection, current ± 0,8mA (pulse 50ms), terminals IN and COM

Platinum temperatuur sensor Pt1000 -200 tot +600°C

± 0,2oC from -200 to +100oC ± 0,2% of measured value from +100 to +600oC

2-wire connection, current ± 0,5mA (pulse 50ms), terminals IN and COM

Nickel temperature sensorNi1000/6180 ppm -50 to +250oC

± 0,2oC from -50 to +100oC ± 0,2% of measured value from +100 to +250oC

2-wire connection, current ± 0,5mA (pulse 50ms), terminals IN and COM

Resistance2-wire 0 to 300 Ohms

0,1% full scale (±0.3 Ohms)

2-wire connection, current ± 0,8mA (pulse 50 ms) terminals IN and COM

Resistance2-wire 0 to 3000 Ohms

0,1% full scale (±3 Ohms)

2-wire connection, current ± 0,5mA (pulse 50 ms) terminals IN and COM

Resistance2-wire 0 to 10,000 Ohms

0,1% full scale (±10 Ohms)

2-wire connection, current ± 0,1mA (pulse 50 ms) terminals IN and COM

Digital input on/off Input voltage for status “L” (IN-COM) <0,8V (Rin < 1 kOhm) Resistance with closed contact at status “L” (IN-COM) < 1 kOhm. Input voltage for status “H” (IN-COM >2 V. Resistance with closed contact at status “H” (IN-COM) > 10 kOhm. Min. pulse duration before pulse is detected: 200ms.

Optional RS485INcommunication input for connection of sensors with RS485 output (Mod-bus or Advantech ADAM protocol) (Order code ATM-AC43).

communication input for connection of sensors with RS485 output (Modbus or Advantech proto-col). Input is suitable for max. 16 appliances. Max Baud speed 115200Bd. Optically isolated.

NB: The inputs are not optically isolated. If optically isolated inputs are required the ATM-055(D) system must be chosen. The ATM-055D that has an extensive range of optical isolated input modules.

Possible types of input with their ranges:

Page 12: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists12

ATM-Analysis software

A user-friendly software program is available for reading and processing measurements made with the ATAL ATM systems. The user interface is formed by a pull-down menu and clear menu bar allowing you to prepare clear displays and reports from the data without problems. The software is divided into two main parts - one for communication and one for the analysis. The software is versatile, complete and very accessible.This allows both beginners and experienced PC users to

Clear display of the readings in graphs and tablesEasy to export data to MS Excel® and to PDF filesExtensive printing possibilities. Professional layout for including graphs and data in monitoring reports

Exporting The data can be exported with one click on the button to an XLS or dbf file for processing and analysis in spreadsheet pro-grams such as MS Excel®. It is also possible to arrange for the export of files to be fully automatic.

Statistics Statistical data can be accessed easily when in table mode. Data such as the minimum, maximum, average, standard deviation and the number of readings saved can be displayed clearly.

Clear presentation of the measured data

u

u

u

Properties

work with the ATAL monitoring systems immediately. The software is suitable for Windows®.

Page 13: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

13

ATMATM-Analysis software

Automatic transfer of data per project or for several projectsIf the ATM-system is linked via a serial (RS232 or RS485), USB, Ethernet or GSM modem connection, the ATM-software is

capable of storing the measurement data auto-matically according to a preset time schedule entered by the user (e.g. daily or weekly). This function is also available if more than one ATM-

system is linked via a RS485 connection.

Real time 16 channel paperless recorderThe ATM-software has standard functions to monitor proc-esses both graphically and numerically in real time. The nu-merical values and the alarm status are displayed on the left, whilst on the right the graphic progression of the activated input channels is presented. This “paperless recorder” func-tion is exceptionally practical for monitoring brief processes such as tests and tuning. This function can also be used if the ATM-system is linked via a modem.

Real time display of HTML pageThe actual measurement data from the ATM-systems are now also available via HTML pages by using the web browser. Several user groups, for example the technical service depart-ment, the person responsibly for quality assurance or the management, can use this function to follow critical proc-esses simultaneously. The actual readings can be displayed via the web interface both in numerical and graphical form. Condition here is that the PC to which the ATM-system is linked forms part of the company network, since this PC func-tions as web server.

Transfer of data

Page 14: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists14

ATM

ATAL Database software

Simple management of data files by using the ATAL Database software

These database software ver-sions replace your present soft-ware and have the additional possibility of saving your data centrally in an SQL database. An integrated Viewer applica-tion for analysing the data is supplied with these database software versions. This Viewer application can also be ordered separately for use by other users on the network who also wish to analyse the data. Some experience with installing PC networks is desirable when in-stalling this particular database software.

There are a number of new software solutions available for users of ATX and ATV data loggers, ATM multiple channel monitoring systems and (Ethernet-based) sensors that make it possible to store the data centrally in a MySQL or MS-SQL

The Database software solutions

DBL-WIN Database software for ATX and ATV data loggersDBM-WIN Database software for ATM 1-16 channel monitoring systemsDBS-WIN Database software for Ethernet-based sensors (with SOAP support - push data)DBV-WIN Database Viewer licence

Characteristics of Viewer software:• Data can be sent easily to a printer or saved as PDF document or exported to CSV format• The instruments are displayed in a clear window• The desired period can be selected immediately• Data from various instruments can be displayed simultaneously in one table or a single graph

database. This software module is particularly suitable for customers using several instruments who wish to compare and analyse large quantities of data (from a range of different types of instruments).

ATX and ATV data loggers

DBL Software incl. Viewer licence

SOAP

ATM 1 - 16 channel monitoring system

DBL Software incl. Viewer licence

Data storage in MySQL or MS SQL

Ethernet-based systems that sup-port SOAP can send the current

readings directly to the database

Analysis using the Viewer application

Page 15: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

15

ATMPossible connections to the ATM-Systems

Possible connections

The ATM-System is a versatile system with many communi-cation possibilities, such as via RS232, RS485, USB, Ethernet and GSM/analogue modem. This allows the system to be configured entirely according to the wishes of the user by using a selection of input modules, so that virtually every de-

sired monitoring application can be accommodated. Sensors can be wired both in star and network form. For those ap-plications where it is complicated to apply wired sensors, our wireless sensors provide a solution. The diagram below gives an impression of the various communication possibilities.

Alarm via:- Analog of GSM modem- SMS- E-mail, SNMP trap- Automatic Telephone Dialer- Acoustic signal

Acoustic alarm unit

PC

Communication via

- USB- RS232- RS485- Ethernet- GSMSMS

GSM modem

Automatic telephone dialer

Alarm outputs - Relay- Voltage signal

230VWall outlet

Power supply

Ethernet RS485

Outputs

External LCD-Display & keypad

Relay output module

Inputs

RS485

Appliance to be controlled Temperarure

converterTRA-105D

Temperature R.H. sensor Third party sensors

Temperature

STRP485-102 Temperature R.H. & ATM-Pressure sensor

TRP485-102 Temperature R.H. & ATM-Pressure sensor

RS485

Wireless receiver (868 Mhz)with wireless sensors

Page 16: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists16

ATM

Sensors and accessories for ATM monitoring systems

Model/sensor type AT-VLB-02 AT-VLH-03ND-A3 AT-VLH-03-A3 AT-VL-03T

Description: CO2-sensor with 3-colored LED-indication

CO2-, temperature & R.H.-sensor with 3-color back lit LCD-display

CO2-& temperature sensor with LCD-display and 3-colored LED-indication

Output signal: 0-5V / 0-10V 3x 0-5V / 0-10V 0-10V

Model/sensor type TRA-102D / TRV-102D TRA-104D/TRV-104D TRA-105D/TRV-105D PA-101D/PV-101D

Description: Temp. & R.H. sensor with LCD-display, for general applications

Temp. & R.H. sensor with LCD-display, with remote sensor probe

Temp. & R.H. sensor with LCD-display, for indoor wall mount purposes

Atmospheric pressure sensor with LCD-display

Output signal: 4-20mA / 0-10V 4-20mA / 0-10V 4-20mA / 0-10V 4-20mA / 0-10V

Sensors for temperature, relative humidity and atmospheric pressure:For ATM-monitoring purposes ATAL supplies a full range of sensors for reliable measuring and control of temperature, relative humidity and barometric (atmospheric) pressure. Both sensors for wall mount and duct mount are available. The range includes sensors for use in outdoor applications as well as sensor for typical use in an industrial environment. The majority of sensors come with a calibration certificate. For further details and the specifications of the sensor range please check out our website www.atal.nl

CO2-sensors:ATAL offers a large variety of CO

2-sensors that come with an output signal that is suitable for connection to the ATM-monitor-

ing systems type ATM-055D and ATM-06D. A brief overview of the CO2-sensor range is given below. For further details and the

specifications of the full sensor range please check out our website www.atal.nl

Active sensors for ATM-Monitoring SystemsATAL supplies an extensive range of passive and active temperature and relative humidity sensors and transducers for physical and electrical parameters.

A brief overview is given below:

Sensors

Carbon dioxide CO2 sensors

Range: 0-10.000 ppm

Output: 0-4 Vdc (0-4000 ppm)

Power supply 9 Vdc or battery

AC Voltage

Range: 0-500 VAC

Output: 0-5 Vdc or 4-20 mA

Power supply 9-30 Vdc

Differential pressure

Range: 0-50 Pa

Output: 0-10 Vdc or 4-20mA

Power supply: 9-30 Vdc

AC current

Range: 0-30, 60 and 120 A

Output: 0-5 Vdc of 4-20mA

Power supply Self-powered

Pressure (gas/water)

Range: 0-10 bar

Output: 0-10 Vdc or 4-20 mA

Power supply 9-30 Vdc

Air velocity

Range: 0-20 m/s or 0-40 m/s

Output: 0-10 Vdc or 4-20 mA

Power supply 9-30 Vdc

Page 17: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

17

ATMWireless sensors for the ATM

WRC-100N

Operating temperature: 0 - 60 °C

Power supply: 8-30 Vdc

Radio standard: ETS 300 220

Frequency: 868-870 MHz (915 MHz US)

Communication: RS232 / RS485 (ATM-RS input)

Output (optional): 0-20 mA (4x), alarm relay

Network: Max. 100 sensors, 9 repeaters

Antenna: External

Dimensions: 130 x 180 x 60 (B x H x D)

Configuration: Via ATAL SensorTrend, the wireless network control software program

Housing: IP40, colour RAL7035 grey

Approval: R&TTE, CE

General wireless sensor specifications:

Operating temperature: -20 to +80 °C

Resolution: 0,1 °C resolution

Accuracy: +/- 0,5 °C (-10 to +80 °C )

Reading interval (M): From 1 sec/max. 99 sec/standard 10 sec (setting via PC)

Transmission interval (Z):

From 5 sec/max. 5 mm/standard 10 sec (Setting via PC)

Frequency band: 868-870 Mhz (915 Mhz US)

Radio standard: ETS 300 220

Open field range: 1000m, inside building range 50 to 80 m; range can be extended by use of a repeater

Configuration: Via SensorTrend software program

Battery: 1xAA 3.6 Lithium battery, easy to replace, lifetime 3 years with standard setting M and lifetime 5 years if M and Z are set to 30 sec.

External power supply: Available as option

Housing: IP65, colour grey

Dimensions: Approx. 88 x 120 x 36 mm (dependent on model of sensor)

Approval: R&TTE, CE

Wireless sensorsA multiple channel, wireless recording system is easy to achieve from now on, and you can also save significantly on your installation costs with the combination of the new ATAL wireless sensors and the ATM-monitoring systems! This is because by using our wireless sensors the cabling costs are effectively reduced to zero. Wireless sensors are available for monitoring temperature, relative humidity, carbon dioxide, current, Voltage and energy consumption. More information about these sensors visit our website www.atal.nl

The receiver is linked to an ATM-RS input module of the ATM-System. If the ATM-RS input module is placed at position 1 of the ATM-unit then inputs 1 to 16 are reserved for the wireless sensors.

Receiver (Base) WRC-100N

WTT-201 / temp. WTT-202 / temp. WHT-201 / temp. / R.H.

Range: -20 to 80 °C -80 to 200 °C (external sensor) -20 to 80 °C / 10 - 95 % R.H.

Resolution: 0,1 °C 0,1 °C 0,1 °C / 0,1 % R.H.

Accuracy: ±0,5 °C (from -10 to 80 °C) ±0,5 °C (from -10 to 80 °C) ±1 °C (from 0 - 40 °C) ±3,5 % RH (from 20 - 80 %)

Sensor: Digital Pt100 of Pt1000 (3-wires) Digital

Probe: Internal External (not included) Internal

-20 to 80 °C -20 to 80 °C -20 to 80 °C Operating conditions:

The ATM-system recorder can now be supplied with an external receiver for receiving data from 1 to 16 temperature or combined temperature and relative humidity wireless sen-sors. The sensors work on the 868 MHz frequency band and have a range of 50 to 80 m. inside a building. The temperature sensors and temperature/relative humidity sensors are battery-powered.

Temperature & relative humidity sensors are specified below. Please consult ATAL or your distributor for detailed specification on the wireless sensors for IAQ (temperature, relative humidity, carbon dioxide), current, voltage and energy consumption

Page 18: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

Data Recording Specialists18

ATM

Accessories for ATM monitoring systems

Communication

Special RS232 connector with terminals, for easy RS232 interface connection

USB-interface cable

RS232-RS485 converter for communica-tion purposes. Whenever the distance between the PC and the ATM-unit is >10 meter.

USB/RS485 converter for USB port at the PC side, for communication purposes. Powered from computer USB interface. Whenever the distance between the PC and the ATM-unit is >10 meter.

Built-in LAN interface connection to Ethernet (Internet) network, for com-munications via the (company) net-work. Communication via: SNMP, SOAP, www pages, Modbus TCP. In case an alarm is triggered, e-mail notifications or SNMP traps are sent to user specified addresses.

External GSM-modem for remote communications and download of data. Complete kit with power adapter, antenna and communication cable. The GSM-modem should be connected to the “master” RS232 port of the ATM-system.

External RS485 Ethernet converter. Multiple ATM-units can be networked to a single Ethernet port. The converter comes with an ac/dc adapter.

Metal brackets to mount an ATM-system against a wall.

Accessory to mount an ATM-system on a DIN rail.

Universal ac/dc adapter 230V-50Hz/24Vdc/1A/24W

Power supply circuit suitable for DIN rail mounting (35mm) 230V-50Hz/24Vdc/2.5A.

ATM-AC30

ATM-AC31

ATM-AC01

ATM-AC23

ATM-AC19

ATM-AC06

ATM-AC44

ATM-PS02 ATM-PS03

Mounting of ATM-systems

ATM-AC33 ATM-AC34

Power Supply

Page 19: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

19

ATMAccessories for ATM monitoring systems

Relay Output Module

Connecting cable for the ATM-monitoring system to the Relay Output Module.

Accessory to mount an Relay Output Module on a DIN rail.

DIN rail incl. spacers to mount the Relay Output Module in the IP65 housing.

Small screwdriver specially designed for connecting cabling to the WAGO con-nector of the ATM unit.

External 16-channel Relay Output Module with 16 relays with alternating contact 230Vac/8A. Each relay can be connected separately via the ATM-system for alarm/control purposes.

ATM-AC35-60CM

ATM-AC35-5M

ATM-AC34

ATM-AC38

ATM-AC36

ATM-AC35-10M

ATM-05-AC01

Mounting of Relay Output Module

External LCD-display module

External LCD screen/keyboard suitable for building into a panel. (The connect-ing cable must be ordered separately, see item ATM-AC35).

ATM-05-AC02

Connecting cable for the ATM-monitoring system to the Relay Output Module. Available in three different lengths.

ATM-AC35-60CM

ATM-AC35-5M

ATM-AC35-10M

External LCD screen/keyboard built in to a plastic housing, suitable for mounting on a wall. Comes with 2 m connecting cable.

ATM-05-AC02E

Water proof casings

IP65 casing suitable to fit an ATM-system. Mounted with DIN rail and holder for ATM-055(D) or ATM-06D system. Dimensions: 270x570x140 mm.

ATM-AC37

ATM-system built into an IP65 casing. The external LCD Display Module is built into the lid of the case. Complete with connecting cable, DIN rail and holder for the ATM-055D or ATM-06D. Dimensions: 270x570x140 mm.

ATM-05D-WP

Page 20: ATM-monitoring systems -  · PDF file  ATM-monitoring systems Universal 1 to 16-channel monitoring systems ATM-features Characteristics and specifications of ATM ATM-input modules

O3 (ozon)

water detectionsound air flow

wirelesssensing wind speed

criticalwater temp.

camerasurveillance wood

moisture

building materialmoisture heating pressure Temp. R.H.

AtmosfericPressure

AC Voltage

Monitoring and datalogging solutions for:

.Monitoring systems.Data recorders / Data loggers .Portable Measurement Instruments .Sensors .Calibration service

Distributor:

© 2012 ATAL B.V. – Specifications are subject to change without previous notice of ATAL B.V. – S.E. & O.