Thermal insulating and formwork system for floor plates
Atlas
ConneCting details
Connecting JaCKodUR atlas to an external thermal insulation Composite system
Composite thermal insulation system
JaCKodUR KF 300 gefiniert gl
Plinth render/Moisture barrier
16/32 mm gravel splash guard
Masonry
interior plaster
membrane
Floor plate
Polythene sheeting
JaCKodUR atlas
levelling layer, grit (e.g.2/5, 4/8) or lean concrete C 8/10
Ballast substructure/ anti-capillary layer
Connecting JaCKodUR atlas to double-walled masonry
Masonry barrier (e.g. made of eVa with non-woven matting)
Brick facing
JaCKodUR Z foil insulation
16/32 mm gravel splash guard
Reinforced concrete girder
JaCKodUR Jds insulating formwork
Masonry
Masonry barrier (e.g. made of eVa with non-woven matting)
Floor plate
Pe film
JaCKodUR atlas
levelling layer, grit (e.g.2/5, 4/8) or lean concrete C 8/10
Ballast substructure/anti-capillary layer
Connecting JaCKodUR atlas to a wood-frame construction
osB board
thermal insulation
Wooden formwork
MdF board
Counter batten/ air space
Plinth render/Moisture barrier
16/32 mm gravel splash guard
thermal installation and/or installation level
gypsum fibreboard
Moisture barrier
Floor plate
Pe film
JaCKodUR atlas
levelling layer, grit (e.g.2/5, 4/8) or lean concrete C8/10
Ballast substructure/ anti-capillary layer
Connecting JaCKodUR atlas to a concrete shuttering stone system
Concrete shuttering stone
Concrete core
exterior plaster
16/32 mm gravel splash guard
Plinth render/Moisture barrier
interior rendering
membrane
Floor plate
Pe film
JaCKodUR atlas
levelling layer, grit (e.g.2/5, 4/8) or lean concrete C8/10
Ballast substructure/ anti-capillary layer
2
thermal insulation must fulfil certain re-
quirements if a building is to comply
with the specifications of the new in-
sulating standards. Processing is a ma-
jor factor, in addition to the material,
quality and thickness of the thermal in-
sulation.
the procedure commonly used at
present for insulating floor plates is no
longer adequate; it is also very time-
consuming and therefore not cost ef-
ficient. the insulation is frequently laid
incorrectly, especially at the top ends
of floor plates. this results in thermal
bridges, which inevitably leads to com-
plaints, and labour-intensive and cost-
ly reworks.
thermal bridges are ruled out by the
system design of the JaCKodUR atlas
thermal insulation and formwork sys-
tem for floor plates. it is laid around the
perimeter beneath so-called load-bea-
ring bedplates. these structurally load-
bearing components absorb the natural
loads of the structure without the need
for additional foundations, and channel
them into the ground.
JaCKodUR atlas is available in thick-
nesses ranging from 100 to 320 mm.
as such, this cost-efficient joining sys-
tem provides insulation that is free of
thermal bridges and formwork for bed-
plates that are suitable for any type of
building.
Certified by Passivhaus institut:
the quality requirements for a peri-
meter insulation system are particu-
larly demanding in passive houses. the
system must ensure U values ≤ 0.15
W/(m2 · K) and that the connections are
free of thermal bridges.
JaCKodUR atlas complies with these
requirements and has been certified
as a component that is suitable for use
in passive houses by Passivhaus insti-
tut darmstadt.
Atlas
3
PRoJeCt RePoRt
Batter boards are used to align the system.
an angle element is laid first, followed by the side elements.
the required number of system ele-
ments is determined on the basis of the
architect‘s plan. once the planning is fi-
nalised, the installation of JaCKodUR
atlas can begin.
the JaCKodUR atlas system compri-
ses four different board elements. ang-
le and side elements are fitted with a
groove, into which the tongue of the
formwork element is inserted. the sur-
face elements have a shiplap at the
edge, which makes it easy to lay them
as a flat surface.
PRoJeCt details
■ insulating system: JaCKodUR atlas
■ surface area: 130 m2
■ insulation thickness: 100 mm
■ installation time: approx.
three hours, three workers
4
the formwork elements are simply slotted into the side elements. the shiplaps ensure that the structure is free of thermal bridges.
the basic framework is completed very quickly, and the surface elements can then be laid.
no tHeRMal BRidges
thermal bridges are ruled out
over the entire floor plate by the
patent pending joining technolo-
gy of JaCKodUR atlas. and yet
the system is so easy to hand-
le that it can be laid very quickly
and perfect installation is
virtually guaranteed.
5
PRoJeCt RePoRt
a hot wire cutter is used to cut the JaCKodUR atlas elements to the right size. it can equally be used to easily cut shiplaps. a tiger or power saw can be used to cut out recesses in the layer of thermal insulation, e.g. for channelling drainage pipes.
6
the thermal insulation and formwork system is quickly laid. the joint system eliminates the need to strip the formwork from the floor plate. additional protection is not needed.
JaCKodUR surface elements must be laid in a bond to avoid cross joints.
Cost eFFiCienCY
the combination of thermal in-
sulation and formwork system
enables both to be completed in
a single step. there is no need to
remove the formwork. and this,
together with the convenient
joining technology means signi-
ficant time – and therefo-
re cost – savings.
7
JAckodur Atlas angle element
Complete with groove for mounting the atlas formwork element
ship-lapped edge
smooth, extrusion-compressed surface
Covering area 1250 x 600 mm = 0.75 m²
Compressive strength 300 kn/m2
also available in compressive strength 500 and 700 kn/m²
Can be combined with atlas formwork element,
atlas side element and JaCKodUR KF standard sF
thickness ranging from 100 to 320 mm
JAckodur kF 300/500/700 Standard SF
surface element for atlas
smooth, extrusion-compressed surface
Covering area 1250 x 600 mm = 0.75 m²
thickness: 100 – 320 mm
JAckodur Atlas side element
Complete with groove for mounting the atlas formwork element
ship-lapped edge
smooth, extrusion-compressed surface
Covering area 1250 x 600 mm = 0.75 m²
Compressive strength 300 kn/m2
also available in compressive strength 500 and 700 kn/m²
Can be combined with atlas formwork element, atlas angle element
and JaCKodUR KF standard sF
thickness: 100 – 320 mm
JAckodur Atlas formwork element
Complete with feather for inserting into atlas angle and side elements
element length: 1.25 m
ship-lapped edge
Can be combined with atlas angle element and atlas side element
thickness: 100 – 320 mm
Floor plate thickness: 200 – 300 mm
other floor plate thickness and dimensions are possible
PRodUCt Range
8
HoW to laY tHe indiVidUal eleMents
5. the shuttering panel is put in the relevant groove. 6. ensure that it is not laid staggered to the surface panel.
2. then a side panel is attached.1. start with a corner panel.
3. the next side panel follows. 4. the surface panels follow.
8. once you have finished, lay a Pe film on top and pull it up at the sides.
7. the elements are really easy to cut with a hot wire cutter. You can even cut shiplaps and ensure that your joints are free of thermal bridges. (not necessary on the complete system)
9
Atlas laying plan
the JaCKodUR atlas complete system is supplied
together with a laying plan
the material is delivered to the building site
on pallets with clearly visible packing slips
the laying plan indicates both the direction of
installation and the procedure for sequential
arrangement of the numbered elements
the laying plan ensures safe and fast realisation
of the installation process
atlas CoMPlete sYsteM
JaCKodUR atlas can also be manufactured as a complete
system instead of the building site solution where the indivi-
dual elements still have to be cut to size.
JaCKodUR is manufactured to size, based on the architect‘s
specifications. the individual elements are systematically pa-
cked and delivered straight to the building site, together with
an installation plan.
the system is made to measure and only needs to be joined
together on the building site. there is no further need to cut
or adapt any of the elements, nor to strip the formwork or
provide side supports.
Even complex
geometries, such as
offsets, bays, etc.,
are possible.
10
teCHniCal inFoRMation
JaCKodUR atlas: technical specifications
Compressive stress at 10% deformation or compressive strength
Cs (10\Y)i level i in kPa en 826 300 500 700
available thicknesses – mm – 100 – 320 100 – 320 100 – 320
nominal value, thermal conductivity
>_ 100 – 180 mm > 180 – 320 mm
λd W/(m·K) en 13164
0,0350,036
0,0370,038
0,0370,038
loss coefficient from thermal bridges, based on external dimensions
Ψa W/(m·K)din en iso
10211< 0
Fire behaviour – Class en 13501-1 euroclass e
Permanent compressive strength, creep behaviour (50 years, compression < 2 %)
CC (2/1,5/50) σ
c
σc in kPa en 1606 130 180 250
Water absorption on long-term immersion Wl (t) i level i in % en 12087 0,7
Water absorption through diffusion Wd (V) i Class en 12088 Wd (V) 3
Resistance to alternating frost-thaw stress FtiK Class en 12091 Ft2
application temperature limit °C -50 up to +75
We require the following information to enable us
to calculate the JaCKodUR atlas complete system
for a construction project:
1thickness of the formwork element 2thickness of the floor plate 3thickness of the insulation beneath the floor plate
Compressive strength of JaCKodUR atlas
simple layout sketch of the floor plate,
including dimensions
Even complex
geometries, such as
offsets, bays, etc.,
are possible.
QUalitY oF tHe tHeRMal insUlation
JaCKodUR atlas is made of extruded polysty-
rene (XPs). the basic JaCKodUR KF materi-
al has been tried and tested over long periods
to guarantee the durable insulation and safe
foundations of the building.
at the same time, JaCKodUR strikes the per-
fect balance between sustainable and
cost-efficient insulation.
1
2
3
11
JAckoN Insulation GmbHcarl-Benz-Straße 8d-33803 Steinhagen
Telephone +49 5204 9955-0Telefax +49 5204 [email protected]
Your dealer
JAC
KO
DU
R®
& J
AC
KO
BO
AR
D®
are
regi
ster
ed t
rade
mar
ks o
f JA
CK
ON
Insu
latio
n G
mbH
who
res
erve
the
rig
ht t
o de
velo
pe o
r ch
ange
its
prod
ucts
at
any
time
with
out
notic
e. R
ef. N
o. 4
504195. g
B 0
9/2
011