AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order....
Transcript of AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order....
![Page 1: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/1.jpg)
AST443 / PHY517
Spectroscopy
![Page 2: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/2.jpg)
Spectroscopy
• The science of breaking the light up into its component wavelengths (or frequencies), generally through use of a dispersive element.
• The resolution R = λ/Δλ. R may range from as low as a few tens in grism spectra to millions.
• The spectrum: a number of adjacent measures of the brightness as a function of wavelength.
• Filter photometry with narrowband filters. It consists of observing a series of single points rather than a dispersed spectrum. A BVRcIc SED has R~4.
![Page 3: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/3.jpg)
Comparing Resolutions
Black: 3.1AGreen: 17A
![Page 4: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/4.jpg)
R= 3000R=78000
![Page 5: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/5.jpg)
Resolution tradeoffslow dispersion, 1D
![Page 6: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/6.jpg)
Astrophysics of Spectroscopy
• Continuua. Spectra of continuua can determine the spectral energy distribution (SED). – Filter photometry is appropriate for many kinds of continuua,
but spectra are needed to show the absence (or irrelevance) of lines.
• Lines. Emission or absorption lines (and edges) are formed by bound-bound or bound-free electronic transitions in ions, atoms, and molecules. Lines are useful for– Determining gas, excitation, and ionization temperatures, – Determining ionization and exitation states, – studying thermal equilibria, – measuring gas density and pressure, – measuring abundances of various species – measuring gas velocities.
![Page 7: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/7.jpg)
![Page 8: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/8.jpg)
![Page 9: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/9.jpg)
Terrestrial H2O lines in N Del
![Page 10: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/10.jpg)
Data smoothed
![Page 11: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/11.jpg)
Na D region in a K star
![Page 12: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/12.jpg)
Hα region in K star
![Page 13: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/13.jpg)
Line Broadening
• Natural line broadening gives rise to Lorentzian-shaped lines, with width of order 10-4A. Lorentzians are of the general form I(Δλ) = A/(Δλ2+B), where A and B are constants.
• Pressure Broadening is due to pertubations of energy levels by nearby atoms, by the Stark effect, Zeeman broadening, etc. The line profile is Lorentzian when thin, and develops a saturated core when thick.
• Thermal Broadening. Due to thermal motions. Gaussian profile. I(λ) = I(λ0) exp(-mc2(Δλ)2/2kTλ2) . HWHM = (2kT loge2/mc2)0.5λ0.
• Turbulent Broadening is due to flows and convection. This includes macroturbulence and microturbulence. It produces a Gaussian profile with a half width = (V2 loge2/c2)0.5λ0.
• Combined line profile. A sum of Gaussians is a Gaussian. A sum of a Gaussian and a Lorentzian is a Voigt profile.
• Rotational broadening. Rotation of a uniform disk gives a profile I(λ) = I(λ0) [1-(c2Δλ2)/(V2λ02)]0.5 The extrema are at ± V sin i.
![Page 14: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/14.jpg)
Center of Mass Motions• Double lines give away a double-lined
spectroscopic binary (SB2).
![Page 15: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/15.jpg)
An Orbit
![Page 16: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/16.jpg)
V471 Tau K2V + DA
![Page 17: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/17.jpg)
Center of Mass Motions
• A single-lined spectroscopic binary (SB1) is given away by varying line velocities.
• Expansion velocities of nebulae. • Radial Velocities.
Δλ/λ = v/c
![Page 18: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/18.jpg)
Spectroscopic Measurements
• Equivalent Widths. ∫dl(Fc - Fl)/Fc– Fc is the flux in the continuum – Fl is the flux in the line. – Units are wavelength. – Absorption lines are positive; emission lines are
negative. – The equivalent width is the width of a rectangular
black line with the same area as the observed line. • Line widths. – FWHM: full width at half maximum. – FWZI: full width at zero intenzity
![Page 19: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/19.jpg)
Diffraction Fundamentals. I.
• Light passing through an aperture is diffracted.Light passing through 2 or more apertures interferes with itself.
• Reflection grating geometry. Each step acts as its own aperture.
![Page 20: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/20.jpg)
Diffraction Fundamentals. II.
• first term: diffraction by a single slit. • second term: interference pattern of N
apertures
![Page 21: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/21.jpg)
Diffraction
• I(θ)/I(0) = sin2(Δ)/Δ2 sin2(Nδ)/sin2(δ). • Let δ = mπ + P (P is the phase). In the limit that P →0, I(θ)/I(0) = N2
• The fringe pattern has zeros where Nδ = m'π, where m' ≠ mN (m, m' are integers). m is the order number (m=0 is the specular reflection, or the zero-order image). The places where m' = mN, the fringe maxima, occur at sin(θ)=(m'λ)/(Nd)
• The resolution R is the distance between successive zeros, or R = 2λ/N d cos(θ).
• A grating diffracts light into many overlapping orders. – The free spectral range, the wavelength difference between two overlapping
points, is sin-1(mλ1/d) = sin-1((m+1)λ2/d), or Σ = λ1 - λ2 = λ2/m. – For small m, orders can be separated with filters (short-pass, long-pass, or
order-sorting). Where m is large, as in an echelle system, care must be taken to separate the orders.
• The slit width does not degrade the resolution so long as the slit width S < λf/(Nd cos(θ)), where f is the focal length of the camera.
![Page 22: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/22.jpg)
Why use a slit?
The slit is generally useful because it :• Can be used to increase resolution (narrow slit) • Excludes sky, decreasing the background signal • Excludes other sources. • Fixes the zero-point. • Slitless spectrographs are used for surveying
emission line sources, or for emission line spectra of extended objects, such as the Sun
![Page 23: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/23.jpg)
Low Order Spectrographs
• mλ = constant (grating constant)• m=0: specular reflection• m=1: first order• Note that long wavelength light may be
contaminated my high order short wavelength light (1x8000 = 2x4000 = 3x2667 = 4x2000)
• Blaze: angle between plane of grating & plane of grooves
![Page 24: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/24.jpg)
Types of Spectrographs
• Rowland Circle. Useful in the laboratory, but not compact enough for telescopes.
![Page 25: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/25.jpg)
Ebert Spectrograph
• Uses flat gratings.
![Page 26: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/26.jpg)
Littrow Spectrograph
• Uses flat gratings.
![Page 27: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/27.jpg)
Wadsworth Spectrograph
• Curved gratings permit compact design.
![Page 28: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/28.jpg)
HST/GHRS
![Page 29: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/29.jpg)
HST/STIS
![Page 30: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/30.jpg)
High Order Spectrographs
• mλ = constant (grating constant)• Used at high m• There will be contamination of orders• Chiron: k ~ 565900– m=100: λ = 5659– m=101: λ = 5603– m=102: λ = 5548
• Requires cross-disperser or order-sorting filters
![Page 31: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/31.jpg)
Echelles
![Page 32: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/32.jpg)
Echelle Grating
![Page 33: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/33.jpg)
Chiron
Tokovinin, A. et al. 2013 AJ 125, 1336
λ/Δλ: 27 400, 79 000, 95 000, 136 000Wavelength coverage: 415–880 nmSpectral orders: 138 to 66Collimator: F = 600 mm, beam diameter 130 mmGrating: 63.9° blaze, 31:6 l/mm, 130 x 260 mmCross-disperser: LF7 prism, apex 62°, one passCamera: oil triplet F = 1012 mm, D . 140 mmCCD: 4096 x 4112, 15 μm pixels, graded-ARFiber feed: 100 μm octagonal core, 2.7ʺ on the sky
![Page 34: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/34.jpg)
ChironCTIO 1.5m
Bench-MountedFiber-FedTemperature-controlledVery stable
![Page 35: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/35.jpg)
Chiron4500-8800AN Del 2013
130928
![Page 36: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/36.jpg)
Cut Through Echelle
![Page 37: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/37.jpg)
STISE140M
1100-1700ARU Lup
![Page 38: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/38.jpg)
STISE140 M1100-1700A
V471 Tau
![Page 39: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/39.jpg)
Spatially-Resolved Spectroscopy
• Spectroscopy classically involves observing one object at a time, and so is inefficient, when compared to imaging photometry.
![Page 40: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/40.jpg)
Long Slit Spectroscopy
Spectroscopy is often done through a long slit.• Permits spatially-resolved spectroscopy in one dimension.• Slits lengths:
– set by the size of the detector and the plate scale– Typically cover a few arcminutes on ground-based
spectrographs. – The HST/STIS slit: 52" long in the optical (26" in the UV) in first
order. – To prevent order overlap, echelle spectrographs generally have
very short slits (0.06" on HST/STIS; a few arcsec on the ground). • Slits can often be rotated to line up objects in the slit. Each point along the slit gives its own spectrum.
![Page 41: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/41.jpg)
Long Slit Example
![Page 42: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/42.jpg)
Sky Subtraction
• Long slits permit sky-subtraction.• This is very useful on moonlit nights.
![Page 43: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/43.jpg)
Long Slit Example
![Page 44: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/44.jpg)
Multi-object Spectroscopy
• A way to take advantage of many objects in the field of view (e.g., a cluster of galaxies or a star cluster) is to use optical fibers to direct the light from many targets to the detector.
• Example: WIYN-HYDRA spectrograph at Kitt Peak. • Hundreds of objects observable simultaneously. • Light losses in the fibers are more than offset by
gains in observational efficiency.
![Page 45: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/45.jpg)
WIYN HYDRA
![Page 46: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/46.jpg)
WIYN HYDRA
![Page 47: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/47.jpg)
WIYN Hydra
![Page 48: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/48.jpg)
WIYN/HYDRA Image
![Page 49: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/49.jpg)
Integral Field Spectroscopy
• The IFU is similar in concept to the fiber-fed multi-object spectrograph.
• Goal: 2-dimensional sampling of the spectra of an extended object.
• A bundle of fibers covers the object, giving spatial resolutions of the projected size of the fibers.
![Page 50: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/50.jpg)
IFU schematics
![Page 51: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/51.jpg)
Wavelength Calibration
You must observe a wavelength calibrator. • Generally an arc lamp– Neon produces strong lines in the red– He-Ar or Th-Ar is used in the blue.
• Each line has a known wavelength λarc
• Measure the position of the line xarc in pixels. • Fit λarc(xarc) with an analytical function • Determine λarc(xarc)
![Page 52: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/52.jpg)
Arc lamps
![Page 53: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/53.jpg)
Spectrophotometric Calibration• Spectrophotometry: the absolute flux as a function of wavelength• Spectroscopic losses:
– Slit loses (seeing; parallactic angle– Fiber transmission– Grating blaze
• To correct these, observe a spectrophotometric standard star, with a well-determined SED (ergs cm-2 s-1 A-1) as a function of wavelength.
• At each wavelength, measure the count rate (counts s-1 A-1). • The ratio of the true flux to the observed count rate gives a wavelength-
dependent conversion factor Fcal (ergs cm-2 / count). – If the night is photometric, and the guiding is good, multiply all spectra by Fcal
to recover the true spectral flux. – If the night is not photometric, you can still use this conversion factor to
recover the relative flux distribution, since clouds tend to be gray absorbers.
![Page 54: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/54.jpg)
What Makes a Good Standard?
• A reasonably bright star – (why waste time doing calibrations?)
• A star with a smooth or featureless continuum.
![Page 55: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/55.jpg)
Spectrophotometric Standard
![Page 56: AST443 / PHY517 · –The HST/STIS slit:52" long in the optical (26" in the UV) in first order. –To prevent order overlap, echelle spectrographs generally have very short slits](https://reader033.fdocuments.us/reader033/viewer/2022060908/60a28f055af7f5522113610a/html5/thumbnails/56.jpg)
Before and after