Aspirating Smoke Detection Pricelist 2009

download Aspirating Smoke Detection Pricelist 2009

of 4

description

Aspirating Smoke Detection pricelist 2009

Transcript of Aspirating Smoke Detection Pricelist 2009

  • .All prices are Ex-works and subject to alteration without notice.Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

    PRODUCT PART NO. PRICE

    HART XL UnitsDetector Unit (Standard Sensitivity 0.005 to 1%/m) 53836-K183 2,105.00Display Module 53836-K182 510.00Intelligent Interface Module With Modem (for use with LaserNet Network)* 53836-K191 1,265.00Intelligent Interface Module Without Modem (for use with LaserNet Network)* 53836-K190 1,116.00* limited stock available

    HART XL AccessoriesInterface Card (Remote inputs for Silence, Reset, Isolate & 4-20mA Output) 44782-K165X 325.26Apollo XP95, Discovery Analogue Addressable Loop Interface Card 44782-K167X 165.82DCC to RG Serial Port Programming Lead (9 way) 53800-H08 19.30

    HART XL CD-ROM (containing HART XL Installation, Operation & Maintenance Manual, LaserNet Software & User Guide)36215-K228 25.00

    HART MiniDetector - Bottom Pipe Entry 53836-K205K-00 1,610.00Detector - Top Pipe Entry 53836-K205K-01 1,610.00Detector - Bottom Pipe Entry (networkable version) 53836-K205KN-00 2,054.00Detector - Top Pipe Entry (networkable version) 53836-K205KN-01 2,054.00

    Power Supply Units & BatteriesSelf Contained Power Supply Unit with space for two 12v 2.0 Ah batteries 53836-K185 438.002.5A Power Supply Unit with space for two 12volt 12 Ah Batteries 53836-K235-00 310.00Battery Box with Space for up to to 18 Ah Batteries 43782-K147 125.4412 volt, 2Ah Battery (For use with 53836-K185) 23911-K051 47.84PS12120 12 volt, 12.0 Ah rechargeable sealed lead acid battery 23911-H10 25.52PS12170 12 volt, 17.0 Ah rechargeable sealed lead acid battery 23911-H11 46.78

    Thame Park Road, Thame, Oxfordshire,OX9 3RT, UKTel: +44 (0) 1844 265003Fax: +44 (0) 1844 265156www.kfp.co.uk

    ASPIRATING SMOKE DETECTION PRICE LIST HIGH SENSITIVITY SMOKE DETECTION

    ISSUE DATE: 1st January 2009 VALID FROM: 1st January 2009

    VALID TO: Until Further Notice

    HSSD Price List 2009 Page 1 of 4

  • .All prices are Ex-works and subject to alteration without notice.Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

    Thame Park Road, Thame, Oxfordshire,OX9 3RT, UKTel: +44 (0) 1844 265003Fax: +44 (0) 1844 265156www.kfp.co.uk

    ASPIRATING SMOKE DETECTION PRICE LIST HIGH SENSITIVITY SMOKE DETECTION

    ISSUE DATE: 1st January 2009 VALID FROM: 1st January 2009

    VALID TO: Until Further Notice

    Senator 25 , 100 & 200 Detectors

    Senator 25 detector including Docking stationSub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum pipework length 50m (25m in high airflow).Dimensions: 140 x 200 x 85

    30671-KID 954.00

    Senator 25 detector including Docking Station and relay/ input cardSub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum pipework length 50m (25m in high airflow).Dimensions: 140 x 200 x 85

    30760-KID 1,054.00

    Senator 100 detector including Docking Station Sub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum pipework length 100m (50m in high airflow).Dimensions: 297 x 200 x 85

    30672-KID 1,300.00

    Senator 100 detector including Docking Station and relay/ input cardSub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum pipework length 100m (50m in high airflow).Dimensions: 297 x 200 x 85

    30764-KID 1,400.00

    Senator 200 DetectorAspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status LED's and menu driven LCD display for indications and programming setup. Relay outputs for interfacing to other fire control equipment. LPCB approved with a maximum pipework length of 200m although unit is capable of operating with a maximum of 250 metres of sampling pipe. Requires 24Vdc power supply (pt no. 30826-KID).Dimensions: 472 x 372 x 95

    30621-KID 1,821.00

    Senator 200 Detector with Command ModuleAspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status LED's and large LCD display for indications and programming setup. Relay outputs for interfacing to other fire control equipment. LPCB approved with a maximum pipework length of 200m although unit is capable of operating with a maximum of 250 metres of sampling pipe. Capable of single point programming and setup for entire SenseNET network (Max 127 detectors). Requires 24Vdc power supply (pt no. 30826-KID)Dimensions: 472 x 372 x 95

    30620-KID 2,689.00

    Senator 200 - Steel enclosureThis is the same as unit 30621-KID in a rugged sheet steel enclosure.

    30706-KID 1,778.00

    Senator 200 with Command Module - Steel enclosureThis is the same as unit 30620-KID in a rugged sheet steel enclosure.

    30707-KID 2,645.00

    Senator 200 - Minumum DisplayThis is the same as 30706-KID with LED status indications for 'Normal', 'Fault' and 'Alarm' only. Programmable via RS485 serial connection port or Command Module.

    30710-KID 1,648.00

    Hazardous area aspirating smoke detection

    Senator Ex Explosion Proof smoke detectorATEX approved aspirating smoke detector EExd IIB + H2 T3, equipment group 2 (zones 1,2 and 3). Group gases A and B + Hydrogen.Sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status LED's for 'Fire', 'Fault' and 'OK'. Relay outputs for interfacing to other fire control equipment. Maximum pipework length 50m still air (25m moving air). Requires 24Vdc power supply.Dimensions: 400 x 200 x 165 inc. Flame arrestors.

    30731-KID 6,852.00

    Senator Ex Explosion Proof smoke detector - Stainless Steel enclosureIdentical to 30731-KID within a stainless steel enclosure

    30732-KID Price on request

    HSSD Price List 2009 Page 2 of 4

  • .All prices are Ex-works and subject to alteration without notice.Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

    Thame Park Road, Thame, Oxfordshire,OX9 3RT, UKTel: +44 (0) 1844 265003Fax: +44 (0) 1844 265156www.kfp.co.uk

    ASPIRATING SMOKE DETECTION PRICE LIST HIGH SENSITIVITY SMOKE DETECTION

    ISSUE DATE: 1st January 2009 VALID FROM: 1st January 2009

    VALID TO: Until Further Notice

    Command Modules

    Stand alone Command Module with internal PSUProvides single location display, control and interfacing options for up to 127 networked Senator detectors, Integral PSU and space for 2 x 12v 17Ah SLA standby batteries.Dimensions: 472 x 372 x 95

    30623-KID 1,822.00

    Stand alone Command Module without PSUProvides single location display, control and interfacing options for up to 127 networked Senator detectors. Requires 24Vdc power supply (pt no. 30826-KID)Dimensions: 472 x 372 x 95

    30624-KID 876.00

    Command Module with PSU - Steel enclosureThis is the same as unit 30623-KID in a rugged sheet steel enclosure.

    30708-KID 1,265.00

    Command Module without PSU - Steel enclosureThis is the same as unit 30624-KID in a rugged sheet steel enclosure.

    30709-KID 833.00

    19" Rack mount Command ModuleSenator Command module housed within a 19" sub assembly for mounting inside standard 19" enclosures. 3U high, complete with 6 x 20mm cable entries to the rear.Requires a suitable 24v power supply with battery back-up.

    30627-KID 1,300.00

    Senator RDU enclosure including Command module Low profile 150mm deep, 9U high enclosure with a glazed lockable front door containing a Senator Command module and space for up to 16 RDUs and relay cards.A suitable 24 power supply with battery back-up is required.

    30823-KID Price on request

    Senator RDU enclosureLow profile 150mm deep, 9U high enclosure with a glazed lockable front door which has space for installing up to 24 RDUs and relay cards.A suitable 24 power supply with battery back-up is required.

    30824-KID Price on request

    Senator Accessories

    Senator relay / input card4 staged relay outputs for interfacing to other fire control equipment. Input terminals for Remote reset, Remote isolate and Remote day/night functions.

    30436-KID 100.60

    APIC - Apollo cardApollo protocol addressable interface card allowing the Senator detectors to be connected directly to the loop of an Apollo protocol control panel.

    30430-KID 133.60

    PS25 intelligent Power SupplyIntelligent wall mountable 24vdc power supply rated at 1.4 Amp. Finished in a neutral colour with sufficient space for 2 x 12V 17Ah SLA batteries. Approved to EN54-4

    30826-KID 208.00

    Senator Bus IsolatorPrevents SenseNET network short circuit isolation for unprotected devices

    30754-KID 122.00

    Interference Suppression ferrite rings (pack of 5) 30711-KID 6.10Senator Serial CableProgramming lead for Senator detector units

    30419-KID 26.00

    Senator Air Heater BoxFor use with Senator detectors when the sample points are installed in low temperature applications

    30422-KID 512.00

    Aspirator with thermostat for use with Heater Box (Part no. 30422-KID), will monitor the operation of the heater element and provide a contact which can be monitored by fire alarm control panel

    30425-KID 262.00

    Wire Burn test rigEnables testing of aspirating systems to BS6266

    30051-KID 347.00

    Wire Burn test wireFor use with wire burn test rig (Part no. 30051-KID)

    21888-K033 14.00

    Smoke Pellets6 x 13g smoke pellets per tube

    21888-K030 8.90

    SenseNET

    SenseNET Remote Display Unit for 19" card frame mountingMimics the displays of Senator detectors via the SenseNET bus. 3U high metal front panel allows it to be installed in a 19" rack enclosure (part no. 30823-KID or 30824-KID), or in a single RDU wall mounting enclosure (part no. 30817-KID)

    30802-KID 144.00

    SenseNET Remote Display Unit relay board (optional)Remote relay board for use with the RDU and provides 4 alarm and common fault relays.

    30803-KID 31.20

    SenseNET Control Unitinterfaces the SenseNET detector unit with PC serial port. Control unit comes complete with connecting cables, power supply unit and PC software.

    30804-KID 1,041.00

    SenseNET Contact Monitorconnects to the SenseNET network and allows monitoring of up to 7 clean contacts from other systems.

    30805-KID 113.00

    HSSD Price List 2009 Page 3 of 4

  • .All prices are Ex-works and subject to alteration without notice.Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

    Thame Park Road, Thame, Oxfordshire,OX9 3RT, UKTel: +44 (0) 1844 265003Fax: +44 (0) 1844 265156www.kfp.co.uk

    ASPIRATING SMOKE DETECTION PRICE LIST HIGH SENSITIVITY SMOKE DETECTION

    ISSUE DATE: 1st January 2009 VALID FROM: 1st January 2009

    VALID TO: Until Further Notice

    RDU 19" Sub Frame19" sub frame with space for mounting up to 8 RDUs.

    30814-KID 114.50

    In-fill plates for 19" Sub FrameBrushed aluminium plates for blanking unused slots in 19" sub frame, plates are the same size as RDU.

    30812-KID 8.70

    In-fill plate with PC portBrushed aluminium plate for sub 19" frame provides socket for connection of PC. PC interface not included.

    30813-KID 43.50

    SenseNET software CD and Dongle 30250-KID 780.00

    Single RDU wall mounting enclosure (RDU not included)Dimensions 150 x 80 x 60

    30817-KID 83.30

    SenseNET (RS485/RS232 CAT5 Converter)Allows SenseNET data to be sent across a CAT 5 Local Area Network (LAN)

    30811-KID 277.60

    PC interface (Software & Dongle not included) 30816-KID 260.00

    SnifferPipe Aspirating Smoke Detection Pipe & Fittings

    Air Sampling Pipe, Red ABS, 25mm diameter (3 metre length) 21888-K016 4.60

    90 Degree elbow - 25mm 21888-K017 1.10

    45 Degree elbow - 25mm 21888-K018 1.10

    Equal Tee - 25mm 21888-K019 2.50

    Straight Socket - 25mm 21888-K020 0.52

    End Cap - 25mm 21888-K021 0.58

    Union Socket - 25mm 21888-K024 3.10

    Pipe Clip - 25mm 21888-K025 0.58

    3/4" BSP Imperial to 25mm Metric Adaptor (See Note 1) 21888-K022 2.00

    1" BSP Imperial to 25/32mm Metric Adaptor (See Note 1) 21888-K023 2.00

    Particle Separator 21888- K163 130.00

    Replacement Foam Elements for Particle Separator 21888-K164 32.00

    Mini Sample Point Assembly c/w 25mm OD Adaptor & 2 metre Capillary Tube 21888-K034 15.00

    Flush Sampling Point Assembly c/w 25mm OD adaptor & 2 metre Capillary Tube 21888-K035 15.00

    Capiliary Tube (10mm OD, 8mm ID) 30 Metre reel 21888-K062 90.00

    Pipe Cutting Tool 21888-K028 36.00

    Pipe Warning Label (100 Labels per roll) 39155-H11 9.00

    NOTE 1: Inlet Adaptors are supplied with Detection Unit as standard.

    HSSD Price List 2009 Page 4 of 4