Integrated Detector Electronics AS ASICs for particle and gamma
radiation detection
Gunnar Maehlum General Manager
6/19/2013 1
![Page 2: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/2.jpg)
Integrated Detector Electronics AS
Founded in 1992 under the name IDE AS as a spin-off from Norway's high energy physics activities at CERN.
Merged with Gamma Medica Inc in 2005
Separated from Gamma Medica Inc in 2013
World leader in design of gamma ray detector systems.
Current systems used in medicine, biology, astrophysics and high energy physics applications.
Unique digital technology.
12 employees from 7 different countries, 3 PhDs, 7 master degrees.
Located at Fornebu near Oslo. Science/space >50% of revenues at present 6/19/2013 2
![Page 3: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/3.jpg)
Product development
• More than 100 different designs of integrated circuits for high energy, nuclear and astrophysics research.
• Bioscope Biomolex microarray imager
• uCAM gamma camera
• LumaGEM Molecular Breast Imaging
• Spectroscopic photon counting
6/19/2013 3
![Page 4: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/4.jpg)
ASIC
6/19/2013 4
![Page 5: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/5.jpg)
Cadmium Zinc Telluride Detector module
CZT Detector showing a CZT crystal and electronics boards Size: 25x25mm Pixels: 256 Pixel size 1.6x16mm
Power consumption 200mW
A usable detector
consists of the
following parts
1. A detector crystal,
often divided into
pixels
2. An amplifier often
implemented as
multi-channel
devices
3. An interconnect and
package
6/19/2013 5
![Page 6: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/6.jpg)
Data Aquisition
6/19/2013 6
Data acquisition card used in a gamma camera for medical diagnostics Developed by GM-Ideas Norway
![Page 7: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/7.jpg)
Gamma Camera for medical use
6/19/2013 7
![Page 8: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/8.jpg)
uCAM gamma camera
• Used for imaging inpre-clinical research
• State of the art energy and position resolution
6/19/2013 8
![Page 9: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/9.jpg)
ASICS for science and research
• A small selection of projects
6/19/2013 9
![Page 10: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/10.jpg)
Belle (KEK, b-factory)
![Page 11: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/11.jpg)
ATHENA antihydrogen detector (CERN)
6/19/2013 11
![Page 12: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/12.jpg)
Astrophysics
The SWIFT satellite: We delivered the readout ASIC for the BAT (Burst Alert Telescope) . The ASIC is just visible as a square below the protective covering on the picture to the left. Launched 2004
The Alpha Magnetic Spectrometer: We delivered the ASICs for the reaout of the silicon charged particle tracker. In total several 10000 channels of preamplifiers.
The Alpha Magnetic Spectrometer: We delivered the ASICs for the readout of the silicon charged particle tracker. In total several 10000 channels of preamplifiers. The experiment flew on the space shuttle. The experiment is visible at the back of the cargo bay. AMS will be installed at the ISS in February 2011.
6/19/2013 12
![Page 13: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/13.jpg)
SWIFT
6/19/2013 13
Observation of gamma ray bursts. Equipped with optical and x-ray telescope in addition to the Burst Alert Telesope CdZnTe and Ideas XA1.2 in orbit November 2004
![Page 14: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/14.jpg)
X-rays from a neutron star
6/19/2013 14
![Page 15: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/15.jpg)
Astrophysics and space weather
The PLAsma and SupraThermal Ion Composition (PLASTIC) experiment on the STEREO mission. GM-I delivered ASIC for read out of detectors of the spectrometer. Launched 2006
SuperAGILE an X-ray monitor of AGILE, by the Italian Space Agency (ASI) devoted to observations for astrophysics in the gamma ray energy range 30 MeV-50 GeV.
6/19/2013 15
![Page 16: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/16.jpg)
astrophysics
•Astro-H
•JAXA mission. We are suppling ASICs to two instruments (of 4):
•Hard x-ray Imaging System: A combination of silicon (<30keV) layers and CdTe (20-80keV)
•Soft Gamma-ray Detector: CdTe 10-600keV
6/19/2013 16
![Page 17: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/17.jpg)
Modular X- and gamma ray sensor (MXGS) on the Atmosphere Space Interaction Monitor (ASIM)
6/19/2013 17
Study x-rays emitted from high altitude phenomena in the atmosphere
Gamma ray spectrometer for the range 20-400keV using Cadmium Zinc Telluride detectors. GM-I delivers detector readout modules to the University of Bergen that will build the spectrometer MXGS
![Page 18: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/18.jpg)
6/19/2013 18
Modular X- and gamma ray sensor (MXGS)
Slide courtesy of University of Bergen
![Page 19: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/19.jpg)
19
CZT Detector array • 100 modules
• a total of 25600 pixels
• Pixels 2.5x2.5mm
• Space qualified R/O system designed by the
University of Bergen
• To be attached to the Columbus module on the
International Space Station
Slide courtesy of University of Bergen
6/19/2013
![Page 20: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/20.jpg)
• Company established with The Norwegian Radium Hospital and private investors
• Technology: double sided silicon microstrip detectors
• Applications: – Real Time Digital Autoradiography – Radionuclides Imaging and
Quantification – Kinase Micro-Arrays – Tissue Sections
6/19/2013 20
imaged slide of near whole-body sections of a mouse injected with an alpha particle emitter radionuclide. The image is 26mm tall.
![Page 21: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/21.jpg)
Spectral photon counting
• Problem: all X-ray images are black & white
• X-rays attenuation depends on photon energy
• Added information when the energy of each photon is recorded
• Challenge: very high photon flux 10E8/mm/s
• Applications in medical imaging, materials sorting, recycling etc.
6/19/2013 21
![Page 22: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/22.jpg)
Spectral X-ray Counting Detector
6/19/2013 22
X-ray Line Camera Modules: CdTe + ASICs Wang et al. (2009), Proc. IEEE NSS
![Page 23: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/23.jpg)
Polaris
• Co-development with the University of Michigan, dept. Of Nuclear engineering, Prof. Z. He
• Directional gamma camera based on Compton scattering
• Measure both time, energy and position of coloumb scattered gamma rays.
• Unsurpassed energy resolution for room temperature detectors
6/19/2013 23
![Page 24: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/24.jpg)
Polaris, a Compton imaging spectrometer
Co-developed by the University of Michigan and GM-Ideas Norway
6/19/2013 24
![Page 25: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/25.jpg)
6/19/2013 25
Compton imaging spectrometer
Developed in cooperation with the University of Michigan groundbreaking ASICs for combined spectroscopy and directional sensitivity
Close to 4pi sensitivity Detect location and energy
of sources with activity 10% above background
Better than 1% energy resolution at 663keV
Visible light image overlay
![Page 26: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/26.jpg)
Some results
• Gamma ray spectroscopy
• Radiation tolerance
6/19/2013 26
![Page 27: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/27.jpg)
Radiation Spectroscopy
6/19/2013 27
![Page 28: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/28.jpg)
Test results – Energy Spectroscopy (1)
VATA450 (low power)
JAXA / KIPAC [Watanabe et al., Vertex 2009] Data taken by JAXA / KIPAC
VA32TA6 VATA450
![Page 29: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/29.jpg)
Test results – Energy Spectroscopy (2)
VATA451 (low noise) Noise (ENC)
VATA450 59 +14 e/pF
VATA451 27 +6.6 e/pF
VATA460 179 +16 e/pF
VATA461 34 + 5.5 e/pF
JAXA / KIPAC [Saito et al.,, SPIE 2010]
ASIC measurements, by GM-I
![Page 30: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/30.jpg)
6/19/2013 30
Test results (3) VATA460 (HDR)
Threshold of Noise
Energy Resolution
(FWHM)
Energy measurement Thresh-hold
En
ergy
[k
eV]
Temperature[degree]
Measurements performed by Takashima et al, JAXA.
![Page 31: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/31.jpg)
6/19/2013 31
Test results (4) VATA460 (HDR)
Energy Resolution (FWHM)
Under CC-on
Energy Resolution (FWHM)
under CC-off
Noise level under CC-off
Noise level under CC-on
Temperature[degree]
En
erg
y [
keV
]
Measurements performed by Takashima et al, JAXA.
![Page 32: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/32.jpg)
Radiation Tolerance and Latch-up
6/19/2013 32
Reference: H.Aihara, M. Hazumi, H. Ishino, J. Kaneko, Y. Li, D.
Marlow, S. Mikkelsen, D. Nguyen, E. Nygaard, H. Tajima, J. Talebi,
G. Vamer, H. Yamamoto, and M. Yokoyama, ”Development of
Front-end Electronics for Belle SVD Upgrades”, IEEE, Proc. Nucl.
Sci. Symp. Conf. Rec. 2000, Vol. 2, 9/213 – 9/216.
The most sensitive structures have been tested for radiation tolerance
ASIC fabricated in 0.35um CMOS process with epitaxial layer.
ASIC fabrication process has been choosen for good radiation tolerance and latch-up immunity.
Initial SEL tests have been performed, and the design has passed these.
![Page 33: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/33.jpg)
6/19/2013 33
Radiation test of VATA460
Radiation test by 6MeV/n He.
Measurements performed by Takashima et al, JAXA.
Gain Noise
![Page 34: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/34.jpg)
What we can offer our customers:
• Advantage: GM-Ideas ASIC were already used at Athena.
• Proven track record of deliveries to scientific customers.
• Internal quality system that is ‘space qualified’
• Predictable delivery times due to own managed multi-project wafers.
• Established internal program to develop ASICs for cryogenic operation (infrared applications)
6/19/2013 34
![Page 35: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/35.jpg)
How to work with us
1. Develop a requirement specification. This can be a collaborative effort to optimize cost/requirement tradeoff
2. Define test and acceptance criteria 3. Based on 1 & 2 We issue a quote 4. Place order 5. Receive ASIC and perform reception control 6. Build and run you experiment/observatory. 1-5 can be performed in as little as 4 months, 6 to 10 more more typical complex designs
6/19/2013 35
![Page 36: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/36.jpg)
GM-I ASIC families
6/19/2013 36
![Page 37: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/37.jpg)
VA ASICs spectroscpy
6/19/2013 37
![Page 38: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/38.jpg)
TA ASICs Triggering
6/19/2013 38
![Page 39: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/39.jpg)
VATA ASICs Self-triggering spectroscopy
6/19/2013 39
![Page 40: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/40.jpg)
Va-Ta architecture
vss
Slow-
shaper
Fast-shaper
S/H
Discriminator Mono-
stable
In
Threshold Ext. S/H
VA
TA
Serial Analog
Out
Trigger
Out
6/19/2013 40
![Page 41: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/41.jpg)
VA-TA timing diagram
6/19/2013 41
Preamp
”Slow” Shaper
”Fast” Shaper
Trigger
![Page 42: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/42.jpg)
XA ASICs Self-triggering spectroscopy
6/19/2013 42
![Page 43: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/43.jpg)
Xa architecture
holdb
ctout
aout
trig-delay
in
HP-F
Reset
DLT
Channel disable-
register thresh
DAC
ff
ff
6/19/2013 43
![Page 44: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/44.jpg)
CA ASICs counting mode
6/19/2013 44
![Page 45: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/45.jpg)
CA Counting ASIC
6/19/2013 45
● 50 ns shaping time, adjustable
● 1.5 Mcps count rate
● 20 keV lowest threshold
● 300 keV dynamic range
● 5 thresholds/windows
● 7 mW/channel
● 32 channel ASIC available
●.. any custom design possible
![Page 46: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/46.jpg)
VAI ASICs current integrating
6/19/2013 46
![Page 47: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/47.jpg)
Pixel ASICs all architectures possible
6/19/2013 47
![Page 48: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/48.jpg)
Pipeline ASICs Oscilloscope mode ASIC
6/19/2013 48
![Page 49: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/49.jpg)
• Any combinations possible
• Back end protocols:
– Asynchrounous data-driven
– Synchronous
6/19/2013 49
![Page 50: ASICs for particle and radiation detection](https://reader034.fdocuments.us/reader034/viewer/2022052619/55539439b4c905ba078b4e2f/html5/thumbnails/50.jpg)
Thank you
6/19/2013 50