Introduction Objective Scope
Quality Control Principle QC Overview QA versus QC General Principle
Basic Requirement of Quality Control Quality control unit Quality control laboratory Responsibility
Quality Control Documents Tasks of Quality Control References
CONTENT OF PRESENTATION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20053
INTRODUCTION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20054
INTRODUCTION
Good Manufacturing Practice (GMP) is the part of Quality Assurance that ensures that products are produced and controlled consistently and reliably. This consistency of production and control is essential. It can only come about by having clear descriptions of the way in which the work will be done.
GMP specifically addresses risks of cross-contamination and mix-up that cannot be fully controlled by testing of the final product.
These risks can best be controlled by having a properly managed system of working that takes them into account. This means that the quality checking system must be designed with these risks in mind and set out to find whether any errors have occurred.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20055
To understand key elements in quality control.
To understand specific requirements on organization, procedures, processes and resources.
OBJECTIVES
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20056
SCOPE
Quality control involved sampling, inspecting and testing of starting materials, in process, intermediate, bulk and finished products.
It also includes where applicable, environment monitoring program, review of batch documentation, sample retention programs, stability studies and maintaining correct specification of materials and products.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20057
QUALITY CONTROL PRINCIPLES
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20058
Sampling
Inspection & testing of: Starting Material, Bulk, Intermediate, Finished product
Environment monitoring program Batch record review/documentation
Sample retention program Stability study Calibration Reagent Handling
Release/Reject: Control for materials & product disposition
QUALITY CONTROL OVERVIEW
Return
How
Reprocessing
Product with consistent quality for its intended use
Assurance
Established Quality System Requirements
Product contain the correct materials of specified quality & quantity
Manufactured under proper conditions accordingly to SOPs
Specification Control
Key Focus Area
Objective
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 20059
• The terms quality assurance and quality control are often used interchangeably to refer to the actions performed for ensuring the quality of a product, service, or process.
• Both terms, however, have many interpretations because of the multiple definitions for the words "assurance" and "control."
• The definitions below, for example, point toward a specific distinction between these two terms:
Assurance = The act of giving confidence, the state of being certain, or the act of making certain.
Assurance : The act of giving confidence, the state of being certain, or the act of making certain.
Quality assurance : All the planned and systematic activities implemented within the quality system that can be demonstrated to provide confidence a product or service will fulfill requirements for quality.
Control : An evaluation to indicate needed corrective responses; the act of guiding or the state of a process in which the variability is attributable to a constant system of chance causes.
Quality control :The operational techniques and activities used to fulfill requirements for quality.
QA VS QC
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200510
Each holder of a manufacturing authorization should have a QC Department
Independence from production and other departments is considered to be fundamental
Under the authority of an appropriately qualified and experienced person with one or several control laboratories at his or her disposal.
If do not have any facility, it can be managed by appointed respective external laboratory institution(s).
GENERAL PRINCIPLES
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200511
BASIC REQUIREMENTS OFQUALITY CONTROL
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200512
Quality Control department should have : resources:
adequate facilities qualified personnel approved written procedures
tasks : sampling, inspecting, testing, releasing or rejecting monitoring
objects : Starting materials, intermediates, bulk, and finished
products Returned products Environmental conditions
BASIC REQUIREMENTS
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200513
• There shall be QC laboratory attached to each manufacturing unit.
• The laboratory shall be capable of performing all the test in accordance to approve specification, or to perform part of test while sub-contracting part of tests to approved contract laboratory.
• Where appropriate, QC laboratories shall be separated from production areas especially for microbiology lab.
• The laboratories should be designed to suit the operations to be carried out in them. Sufficient space should be given to avoid mix-ups and cross-contamination. There should be adequate suitable space for sample and records.
• Separate rooms may be necessary to protect sensitive instruments from vibration, electrical interference, humidity, etc.
QC LABORATORY
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200514
• Large firms : Quality Control Unit(s).
• Small firms : specific tasks unit with limited laboratory apparatus,
or contract analysis with respective external laboratory
institute(s)
• Responsibilities defined in written procedures
• Independence from production and other departments is fundamental
• Under the authority of an appropriately qualified and experienced person
QUALITY CONTROL UNIT
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200515
RESPONSIBILITIES• Examines, approves or rejects incoming materials,
intermediates, bulk, the finished products, and returned products.
• Does the inspection during production (in-process control) • Establishes, standardizes, and implements all QC procedures,
and also establish the specification of each incoming materials.
• Establishes specification of intermediates, bulk and finished goods together with head of Production.
• Approves reprocessing instruction and rework instruction • Reviews production records to determine errors and ensures
that investigations have been conducted and corrective action taken
• Involves in all decisions concern with the product quality
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200516
Establishing, verification, and implementing all QC procedures
Evaluating, maintaining, storing, and monitoring all reference standards and retained samples
Reviewing batch documentation Maintaining correct specification of materials and
finished products Stability testing of each finished product Participating in :
complaint investigations environmental monitoring GMP training
OTHER RESPONSIBILITIES
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200517
QC DOCUMENTS
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200518
Each specification shall be approved, signed and dated, and maintained by QC unit
The following specification shall be minimally maintained and controlled:Starting materials specificationProcess water specification Intermediate or bulk product where
applicableFinished product specificationMaster formulaBatch Manufacturing Record (BMR)
SPECIFICATION CONTROL
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200519
The following details should be included in the specification: designated name, and internal code reference if
applicable qualitative and quantitative requirement with acceptance
limits
Depending on the company practice, other data may be added to the specification: the supplier and the original producer direction for sampling and testing, or reference to an
approved procedure storage condition or precautions the maximum period of storage before re-examination
STARTING MATERIAL SPECIFICATION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200520
• Drinking water standard is defined as minimum standard for use in cosmetic processing. Appropriate specification for chemical and
microbial quality should be established based on point of use.
Periodic testing should be conducted, eg. weekly
• Further treatment may be necessary based on the product formula, process and claim requirements. Specification for water with further treatment shall be established based on supplier design specification or pharmacopoeia standard Microsoft
PowerPoint Presentation
PROCESS WATER SPECIFICATION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200521
Finished product specification should include: Designated name, and internal code reference if
applicable Formula number Description of finished product and its package details Qualitative and quantitative requirement with
acceptance limits Direction for sampling and testing, or reference to an
approved procedure Storage condition or precautions, if any Shelf life, if any Batch numbering requirement (including
manufacturing date or expiry date )
FINISHED PRODUCT SPECIFICATION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200522
• Inspection and testing based on process monitoring or actual sample testing at defined sampling interval and location
• Shall be documented in Batch Manufacturing Record
• The result shall conform to Batch Manufacturing / Packaging Record requirements
• Control chart/other statistical tools for process capability may be used for trend analysis
IN-PROCESS CONTROL
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200523
Other laboratory documentation includes
Sampling procedures
Calibration and Maintenance Equipment
Stability Procedures, where applicable
Environment Monitoring, where applicable
Testing procedures and records (including worksheets and/or laboratory notebooks)
Analytical reports and/or certificates
OTHER LABORATORY DOCUMENTATION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200524
• Master Formula and Batch Manufacturing Record shall be retained for the shelf life + 1 year of the product
• Other laboratory record (e.g. analytical tests results, environmental controls…) it is recommended that records be kept in a manner permitting trend evaluation
• Other raw data such as laboratory notebooks and/or records should be retained and readily available
QUALITY RECORD RETENTION
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200525
TASKS OF QUALITY CONTROL
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200526
4. Test samples
Meet specification
YES
NO
5. Review of batch record
7. Non conformance or out of specification
investigation
6. Goods release
End
Start
3. Sampling
2. Receiving
8. Goods Reject
End
Lab Records
ReleaseRelease
QC/QA Status
QuarantineQuarantine
RejectReject
RejectRejectReleaseRelease
• Incoming materials
• Water• Returned goods
• Intermediates• Bulks• Finished goods• Environment
monitoring
QuarantineQuarantine
QC WORK FLOW
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200527
• There should be written procedure on the receiving, internal labeling, quarantine and storage of starting materials, packaging materials and other materials as appropriate
• Upon receiving of the supplied goods, its identity, legibility of batch number, integrity of its primary packaging and seal shall be verified prior to acceptance.
• Certificate of Analysis shall be provided by the supplier accompanying the receiving of starting materials
• Quarantine goods shall be segregated from “Release” goods
• Reject goods shall be stored in a define area with consideration of control access (eg. Locked area)
RECEIPT
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200528
The sample taking shall be done in accordance with written procedure that describe: The method of sampling The sampling tools used The amount of samples to be taken The type and condition of the sample container
to be used (ie amber glass bottle) The identification of the container sampled Special precaution for hazardous materials The storage condition (if any) Instruction for cleaning and storage of
sampling equipment Instruction for re-sealing the opened container.
SAMPLING
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200529
SAMPLING PROCESS• Sampling tools such as knives, pliers, saws, hammers,
wrenches, implements to remove dust (preferably a vacuum cleaner)
• Material to re-close the packages (such as sealing tape), as well as self-adhesive labels to indicate that a part of the contents has been removed from a package or container.
• Containers due to be sampled should be cleaned prior to sampling if necessary.
• There should be a written procedure describing the sampling operation. This should include health and safety aspects of sampling.
• The container used to store a sample should not interact with the sampled material nor allow contamination. It should also protect the sample from light, air, moisture, etc., as required by the storage directions for the material sampled.
• Microbiology sampling tools shall be sterilised prior to use• Aseptic technique shall be used during sampling
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200530
1. Raw MaterialSampling plan for raw material should be based on defined sampling standard, for example: • the “n plan” is based on the formula n = 1+√N, where N
is the number of sampling units in the consignment;• the “p plan” is based on the formula p = 0.4 √N, where
N is the number of sampling unit; or • the “r plan” on the formula r = 1.5√N . • reduce sampling plan such as “p plan” shall be
considered only when there is established confidence on the material’s uniformity.
2. Packaging materials and Finished ProductSampling plans for packaging materials should be based on defined sampling standards, for example British Standard BS 6001-1, ISO 2859 or ANSI/ASQCZ1.4-1993.
Microsoft Word
Document
SAMPLING PLAN
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200531
Scoop for solid
Dip tube for liquid
Weighted container for large tank
Spears for bag
SAMPLING TOOLS
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200532
TESTING & ANALYSIS
• All tests shall be performed in accordance with the test methods as stated in the specification
• Reduce testing rational shall be documented• Test can be performed by in-house laboratory
or external laboratory• Where test is performed in-house, laboratory
shall be available
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200533
LABORATORY DATA (1) QC should maintain adequate analytical
records concerning the examination of materials and products.
Such records should include among others: The result of every test performed, including
observations and calculations, relating to compliance with the established specifications (calculations done on scratch paper shall be included in the record).
The source of the specification used. Signature(s) of the person(s) who performed the
quality control procedure. A final review (eg. laboratory management), the
decision taken, and a dated endorsement by a duly authorized expert (eg. supervisor/manager).
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200534
LABORATORY DATA (2)
• Laboratory data must be recorded in a manner that assures its accuracy, authenticity and completeness, preserves its integrity and assures its retrievability
• Data recording should be clear, permanent (not pencil) and traceable to the item tested.
• Records, either handwritten or equipment/ computer generated, shall be reviewed, signed off and dated.
• There should be a written policy about averaging of numbers, cross-outs of mistakes, significant figures, leaving notebook pages or fill-in-the-blank entries empty, etc.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200535
RETAIN SAMPLE (1)
• Retain sample should be representative of the batch of materials or products from which they are taken.
• Retain sample shall be of a size sufficient to permit at least 2 full re-examinations
• Retain samples for each batch of finished products shall be retained at a defined period
• Finished product should be kept in their final packaging and stored under the recommended condition (eg. Consumer use condition at room temperature)
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200536
RETAIN SAMPLE (2)
• A retain sample log shall be maintained with the sample identification, batch number and its storage location for ease of retrieval
• Prior to disposal of retain sample, visual inspection should be carried out
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200537
CONTROL OFSTARTING MATERIAL ACCEPTANCE
1. All starting materials shall be verified prior to use.
2. Verification should include the following: Review of Certificate of Analysis from the manufacturer
versus approved specification Other tests may be conducted as appropriate:-
Identification test / package identification and other characteristic of the material shall be examined.
Primary packaging: No leakage, sharp dents, tear , exposed parts and seal integrity
Legible label and identification and batch number Frequency: Every batch of manufacturer’s batch
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200538
CONTROL OFPROCESS WATER ACCEPTANCE
• Minimally meet National or WHO Drinking Water standard.
• Treated water specification shall be based on supplier’s design specification or pharmacopoeia standard
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200539
CONTROL OFIN-PROCESS BULK/PRODUCT ACCEPTANCE
• In-process inspection and testing should be performed by monitoring the process or by actual sample analysis at defined locations and time.
• The results should conform to established process parameters or acceptable tolerances.
• Line clearance shall be practiced on all packaging lines
• Where necessary, standard reference for labeling and coding format/ requirement should be available.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200540
CONTROL OFFINISHED PRODUCT ACCEPTANCE
• Review of Batch Manufacturing Record• Review all non-conformance or deviation
documented on the BMR and its reprocessing or rework instruction
• Review of physical, chemical and microbiological results
• Review of sample from the batch for verification on its conformance to BMR requirement.
• Approve Certificate of Analysis with clear summary statement on the product status, ie “Release” or “Reject”
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200541
OUT OF SPECIFICATION INVESTIGATION Written procedure should be made available. Typically, an investigation includes:
• A review of the calculation to ensure they are correct.• A review of test procedures utilized.• A review of equipment, columns, charts and previous
analyses of samples of the same product/material• A review of reagent/ standardization carried out for the test
(e.g., pipettes).• A complete investigation and evaluation of initial results
prior to a retest.• A review of product/material history• Assigned person responsible for investigation• Documented rational for retest and re-sampling
Proper documentation of investigations, recommendation and disposition must be in place.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200542
LABORATORY REAGENT• Reagent should be prepared in accordance with written
procedures.• Volumetric solution, the last date of standardization and
the last current factor should be indicated. • Where necessary, the date of receipt of any reagents
should be indicated on the container. Instruction for use and storage should be followed.
• Where necessary, the identification test and/or other testing of reagent materials is required upon receipt or before use.
• Reagent to be certified by the original producer to the quality of reagent grade purchased, typically a CoA shall be available for review and verification on acceptance.
• Laboratory safety manual shall be available for safe operation of the reagent and chemicals.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200543
LABORATORY REAGENTS
All reagents should bear a label containing the following information :
The name of the reagentIts strength or concentrationIts expiration dateDate of preparation Name of the individual who prepared itMaterial Safety Data Sheet (MSDS)
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200544
ENVIRONMENT MONITORING (1)• Environment Monitoring to be implemented
where appropriate.• The objective is to demonstrate the
manufacturing environment is functioning at an adequate level of microbial control for the specific product/product group.
• Sample site selection based on:Room design/ sizeManufacturing process Product susceptibility
• Potential sampling site shall include Starting material sampling room/areaDispensing areaManufacturing areaMicrobiological lab
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200545
ENVIRONMENT MONITORING (2)
• Alert and Action limits should be established based on statistical methods.
• Sampling frequency shall be established, eg weekly.
• The media selection for use of detection and growth of viable airborne particulate shall be established.
• Direct and in-direct methods available, most commonly used are STA air sampler, SAS air sampler and settling plate.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200546
STABILITY STUDY (1) Stability test shall be carried out where applicable
Real time stability shall extend to the end of shelf life period for any new products and should include the following parameters:- Number of batch(es) for different batch size Relevant physical, chemical, microbiological test methods Acceptance criteria Description of the container closure system(s) Testing intervals (time points) Description of the condition of storage
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200547
STABILITY STUDY (2)• The number of batches and frequency of testing
shall provide a sufficient amount of data to allow for trend analysis.
• Bracketing and matrixing design may be applied where applicable.
• Worst case situation shall be covered within the real time stability program after any significant change or deviation to the process or package, ie. After rework or reprocessing.
• A summary of data should be generated, with interim conclusion on the trend analysis.
• Result of stability studies should be reviewed by authorized person(s).
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200548
CALIBRATION• To maintain the accuracy and precision of test
equipment at all times.• To ensure highest level of confidence in all
measurement that affect materials disposition decision, with unbroken chain of traceability to national standard.
• To determine whether the equipment is still fit for its intended purpose.
• It is based on the comparison of a primary standard or instrument of known accuracy with another equipment (to be calibrated)
• It is used to detect, correlate, report or eliminate by adjustment of any variation in the accuracy of the equipment being calibrated.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200549
EQUIPMENT CLASSIFICATION Critical equipment:
Direct measurement that affect the final product quality
Measurement on critical process parameters in the process specification
Non critical equipment: Indirect measurement that will not directly
affect the final product qualityShall be maintained based on company
maintenance schedule
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200550
CALIBRATION INTERVAL
Depending on: Classification of Critical or non-critical Usage (light or heavy usage) Handling (light or heavy handling) Manufacturer’s recommendation Reference to NIST or accreditation
body guideline for a specific measurement system
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200551
PRIMARY STANDARD
• Highest accuracy order in the measurement system
• Traceable to National or International standard
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200552
Note: * Working Standards
REFERENCE STANDARD*/MATERIAL
• Reference Standard It shall be calibrated by a body that can provide traceability. Such reference standard of measurement held by the laboratory shall be used for calibration only. It shall be calibrated before and after any adjustment
• Reference Materials Where possible, it shall be traceable to SI units of measurement, or to Certified Reference Materials. Internal Reference Material shall be checked as far as is technically and economically practical
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200553
CALIBRATION RESULT
• Traceable to National or International standard
• Measurement standard to be specified with validity period
• Conclusion made on the validity of calibration
• Certificate to be reviewed by authorize personnel
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200554
VERIFICATION
• Applicable to equipment that cannot be calibrated (adjustment, correlation, etc)
• Verification against measurement standard with correction factor documented
• Actual reporting of result shall include the correction factor
• Temperature correction factor “- 2 0C”. Measured value: 240 CReported value = 24 0 C –2 0 C= 22 0 C
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200555
OUT OF CALIBRATION
• Remove equipment from use• Out of Calibration Investigation to be
carried out to determine the source of inaccuracy
• Evaluate the impact of OOC result on the final product quality and other previously measured data
• All investigation findings should be documented
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200556
CALIBRATION RECORDS• Calibration Master Plan
Include the control of all critical measurement equipment that contain the following details Name Identification by model # and serial # Location Owner/Responsible Calibration Frequency Calibration due date
• Calibration Certificate• Calibration Procedure
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200557
CALIBRATION CERTIFICATE• Name and address of contracted
calibration laboratory• Name and address of client• Description and identification of item
calibrated• Environment conditions when calibration
was made• Date of receipt of instrument, date of
calibration and date of next calibration• Calibration method• Result of calibration• Signature and title of person responsible
for the calibration• External calibration contract shall be
awarded to Accredited by the nation institution
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200558
CALIBRATION IDENTIFICATION
• Status of equipment calibration shall be available and affixed to the equipment where applicable.
• Equipment identification shall bear the following information: name of equipment serial no. date calibrated status schedule of next calibration and initial/signature of the person who
performed the calibration
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200559
REPROCESSING (1)• Reprocessing includes both definitions of
Reprocessing and Rework • Definitions
Reprocessing: Subjecting all or part of the batch/lot of an in-process bulk, intermediate or product of a single batch or lot to the previous step of the approved manufacturing/packaging process due to failure to meet pre-determined specification.
Rework: Subjecting all or part of the batch /lot of an in-process bulk, intermediate or product of a single batch or lot to an alternate manufacturing/ packaging process due to failure to meet pre-determined specification.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200560
• Complete OOS/Non-conformance investigation with risk assessment on recovery decision, based on approved procedure
• Reprocessing Instruction includes the following details:
Additional Ingredient where necessaryReprocessing instructionResponsibilitySampling PlanAcceptance Criteria
• Approval of Reprocessing Instruction by QC
• Where batch adjustment which is part of the In-Process Quality Control, this should not be considered where there is reprocessing.
REPROCESSING (2)
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200561
CONTROL OFREPROCESSING PRODUCT
• Meeting the Reprocessing Instruction acceptance criteria
• Where the stability of the product is in doubt, additional testing of any finished product which has been reprocessed should be performed, stability study to be included as appropriate.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200562
RETURN (1)• Definition- Finished product that has been
distributed and is being returned for reasons other than a product complaint reason.
• Returned products shall be identified as such and put on hold. If the conditions under which returned products have been held, stored, or shipped before or during their return, or if the condition of the product, its container, carton, or labeling, as a result of storage or shipping, casts doubt on the safety, identity or quality of the product, the returned product shall be destroyed unless examination, testing, or other investigations prove the product meets appropriate standards of safety, identity or quality.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200563
• A product may be reworked/reprocessed provided the subsequent product meets appropriate standards, specifications, and characteristics.
• Records of returned products shall be maintained and shall include the name, lot number (or control number or batch number), reason for the return, quantity returned, date of disposition, and ultimate disposition of the returned product.
RETURN (2)
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200564
RETURN (3)
• If the reason for a product being returned implicates associated batches, an appropriate investigation shall be conducted.
• Procedures for the holding, testing, and reprocessing of returned products shall be in writing and shall be followed.
• The recovery rational shall be documented with approval from the QC unit.
• Disposal of return goods shall be based on approved procedure.
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200565
CONTROL OF RETURN PRODUCTS Products that have been subjected to improper storage
conditions including extremes in temperature, humidity, smoke, fumes, pressure, age, or radiation due to natural disasters, fires, accidents, or equipment failures shall not be salvaged and returned to the marketplace.
Whenever there is a question whether products have been subjected to such conditions, salvaging operations may be conducted only if the following acceptance criteria were fulfilled: Product labeling meeting current regulatory
requirements Laboratory tests that the product meet the product
specification Visual inspection on the product and their associated
packaging were intact and comparable to standard
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200566
Trainer Manual of GMP ASEAN Quality Control ASEAN GMP Supplementary Module : Water ASEAN GMP Supplementary Module : Calibration WI of QC Working Procedure WI of Sampling of Incoming Raw Materials WI of Sampling of Incoming Packaging Materials WI of Handling Incoming Materials WI of Handling Finished Goods WI of Handling and Testing of Raw Materials WI of Stability Study WI of Environment Monitoring
RELATED HYPERLINK DOCUMENTS
Project co-financed by European Union Project co-
financedby Asean
European Committee for StandardizationImplementing Agency
Module 7Module 7 GMP Workshop Kuala Lumpur 14-GMP Workshop Kuala Lumpur 14-
16 Nov 200516 Nov 200567
REFERENCES1. Guideline on ASEAN Cosmetic GMP (2003)2. U.S. Food Drug Administration, Center for Food Safety
Applied Nutrition, Cosmetic Compliance program 3. NIST4. WHO Guideline for Drinking Water Quality5. EUDRALEX, Medicinal Products for Human and
Veterinary Use : Good Manufacturing Practice, ,Volume 4.
6. WHO, Good Manufacturing Practices: Starting Materials.7. Ariffin F., Consultation to Discuss : Stability Studies in a
Global Environment. 8. International Pharmacopoeia 9. WHO Guideline For Sampling OF Pharmaceuticals and
related materials.10. PDA Technical Report No. 13 revised, Fundamentals of