Instrumentation Cables
IntroductionSpecialty Cables
300V & 600V Instrumentation Cable TypesCertificates and Standards300V Applications and Description300V 105°C PVC Insulated, Unshielded Pairs ITC/PLTC300V 105°C PVC Insulated, Unshielded Triads ITC/PLTC300V 105°C PVC Insulated, Unshielded Pairs with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Unshielded Triads with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Individual Pairs with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Individual Triads with Overall Shield ITC/PLTC600V Applications and Description600V PVC/Nylon/PVC Overall Shielded Pairs/Triads TC-ER Rated600V PVC/Nylon/PVC Individual and Overall Shielded Pairs TC-ER RatedNotice
::
::::::::::::
2 - 34
678 - 910 - 1213 - 1516 - 1819 - 2122 - 242728 - 2930 - 3134
INDEX
www.2mkablo.com 2
2M CABLE CO. INC. Founded in 1993, 2M CABLE is a high-technology cable manufacturer specializing in all types of Low Voltage cables. The company is headquartered in Istanbul, Turkey and operates in a 270.000 ft2 area. Our Sales office and a warehouse in Moscow/Russia has succesfully been active since year 2005.
2M CABLE has been a reliable manufacturer and supplier to the sectors such as; Construction (High rise, intelligent&semiintelligent buildings, hospitals, universities, residence projects, etc.), Oil & Gas, Petrochemical, Power Plant Projects,Automation, Fire & Security, Satellite, Broadcasting, Audio-Video … We export to more than 50 countries worldwide (Mostly to Europe, MEA Countries, CIS Countries and South East Asia).
Introduction
www.2mkablo.com3
Instrumentation Cables
2M CABLE manufactures instrumentation cable mostly for refineries and petrochemical plants. Our Engineering and Designing team have knowledge of supporting cable needs for large projects in USA, Europe, Middle East, South East Asia, South America and Far East.
TRAY CABLES Tray cable, made for Control and Signaling Systems (*NEC Article 336) are used in petrochemical refineries, industrial control systems, intercom systems, traffic controls relay, power extensions. The cable is recognized for use in Class 1 and 2, Division 2, hazardous locations and for installation in trays, wire ways, troughs, ducts, conduit and channels.
ITC/PLTC CABLESITC/PLTC Cables have a wide range of application in process control and data processes, in analogue and digital signal transmission and power limited circuits. Factories, burglar alarms, business machines, refineries, petrochemical plants, intercom systems, industrial control systems, power plants, natural gas filling plants and etc. make up the general areas that these cables are used.
We are also capable of designingand manufacturing tailor madecables customized according to your specificneeds and as peryour requirements of application.Many types of cables are availableat your request.
Specialty Cables
www.2mkablo.com
www.2mkablo.com
2M CABLE UL 300V Instrumentation Cable Meets All Applicable SpecificationsUL 13UL 2250UL 1685NEC Type PLTC per Article 725NEC Type ITC per Article 727
For International Projects, the quality certificates we have & the standards we follow; Certificates LPCBVDERINA
StandardsIECBSENGOSTTSE
300V Instrumentation Cables
www.2mkablo.com7
300V Instrumentation Cables
300V, PVC Insulated, 105°CType PLTC – UL 13 – NEC ART 725Type ITC – UL 2250 – NEC ART 727
ApplicationsSoft annealed bare or tinned copper conductors and PVC flame retardant insulations and jackets are the standard for 300V instrumentation installation. Constructions with PVC/PVC that have three or more conductors and 20 AWG or larger conductors may also be used for direct burial installations.
Construction
ConductorBare, Tin-Coated, annealed copper, in solid, 7-strand, or 19-strand configurations from 20 AWG to 12 AWG.
InsulationPolyvinyl chloride in accordance with UL 13 and UL 2250, flame retardant, 105°C temperature rating.
Insulation Shield (on shielded pair/triad constructions):2M Cable provides many options for shielding to prevent EMI (electro-magnetic interference) within the twisted pairs, triads and for the overall cable using Overall Foil Shield, Aluminum/Polyester Foil and Aliminum Foil.
JacketUL listed sunlight and moisture resistant, black, flame retardant polyvinyl chloride material.
Features• UL approved Type PLTC and ITC, 300V• UL approved insulated conductors• Cables pass UL 1685 and IEEE 383 vertical fire tests at 70,000 BTU/hr• Temperature rating 105°C• Sunlight and moisture resistant jacket• UL 13 and 2250: The overall jackets of these cables are a “gas/vapour tight continuous sheath”• in Class 2 and Class 3 Circuits, as defined in NEC ART 725 for Type PLTC cables.
www.2mkablo.com 8
300V Instrumentation Cables
300V 105°CPVC Insulated Unshielded Pairs ITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8) Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer) Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C) colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250
Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil Resistance
:: :: : : ::::
:
300 VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft) 6.95 Ω/kft 10.92 Ω/kft20.08 14.97 14.97 11.82100.1 at 15.6°C fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)
www.2mkablo.com9
300V Instrumentation Cables
12461012182450
12461012182450
12461012182450
12461012182450
*14/7
*16/7
*18/7
*20/7
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0150.0150.0150.0150.0150.0150.0150.0150.015
0.0150.0150.0150.0150.0150.0150.0150.0150.015
0.0120.0120.0120.0120.0120.0120.0120.0120.012
0.510.510.510.510.510.510.510.510.51
0.380.380.380.380.380.380.380.380.38
0.380.380.380.380.380.380.380.380.38
0.30.30.30.30.30.30.30.30.3
0.0400.0500.0600.0600.0700.0700.0800.0800.090
0.0350.0500.0500.0600.0600.0700.0700.0800.090
0.0350.0500.0500.0500.0600.0600.0700.0700.080
0.0350.0400.0500.0500.0600.0600.0600.0700.070
1.021.271.521.521.781.782.032.032.29
0.891.271.271.521.521.781.782.032.29
0.891.271.271.271.521.521.781.782.03
0.891.021.271.271.521.521.521.781.78
0.3130.4780.5720.6830.8880.9161.0931.2781.735
0.2550.3990.4620.5690.7140.7580.8841.0501.417
0.2310.3600.4150.4900.6350.6590.7860.9121.235
0.2000.2890.3480.4070.5290.5450.6310.7500.991
3057
113169280302503671
1394
193772
108177213319424882
12234668
112134200266553
81529437185
126168347
7.9412.1414.5417.3422.5623.2627.7632.4644.08
6.4810.1411.7414.4418.1419.2622.4626.6635.98
5.889.14
10.5412.4416.1416.7419.9623.1631.36
5.087.348.84
10.3413.4413.8416.0419.0625.16
4485
168251417450749998
2075
2955
107160264317474631
1312
183468
101166200298396823
12224364
105126187250517
80181305447758854
125716973346
51122194296481562803
21642606
3893
144208355400589790
1546
275899
139239265374521985
119270454665
11281271187025254979
76182289440716837
119532203878
57139215310529596877
11762301
4086
147207355395556775
1466
www.2mkablo.com 10
300V Instrumentation Cables
300V 105°CPVC Insulated Unshielded Triads ITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer) Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250
Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil ResistanceSunlight Resistance
:: :: : : ::::
::
300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft20.08 14.97 14.97 11.82100.1 at 15.6°Cfixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200
www.2mkablo.com11
300V Instrumentation Cables
*14/7
*16/7
*18/7
12468101216182450
12468101216182450
12468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.510.510.510.510.510.510.510.510.510.510.51
0.380.380.380.380.380.380.380.380.380.380.38
0.380.380.380.380.380.380.380.380.380.380.38
0.0400.0500.0600.0700.0700.0700.0700.0800.0800.0900.090
0.0400.0500.0500.0600.0600.0700.0700.0700.0700.0800.090
0.0350.0500.0500.0600.0600.0600.0600.0700.0700.0700.080
1.021.271.521.781.781.781.782.032.032.292.29
1.021.271.271.521.521.781.781.781.782.032.29
0.891.271.271.521.521.521.521.781.781.782.03
0.3280.5290.6350.7820.8800.9911.0301.1641.2271.4601.960
0.2810.4430.5130.6310.7100.8210.8490.9390.9911.1801.609
0.2430.3990.4580.5650.6310.7100.7340.8330.8801.0261.388
4284
168252335419503670754
10052091
2754
107160213266319425477636
1322
173468
101134167200266299398827
8.3413.4416.1419.8622.3625.1626.1629.5631.1637.0849.78
7.1411.2413.0416.0418.0420.8621.5623.8625.1629.9640.88
6.1810.1411.6414.3416.0418.0418.6421.1622.3626.0635.26
63125250375499623749997
112214953112
4080
159238317396475632710946
1967
2550
101150199248297396445593
1231
103243414632816
103811821549173623864667
69163263403518679770989
110615233004
49122194296381480544719800
10832135
154362616940
1215154417592305258435516945
103243391599771
101111461472164622674470
73181289441567714810
1070119116123177
www.2mkablo.com 12
300V Instrumentation Cables
12468101216182450
*20/7
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012
0.30.30.30.30.30.30.30.30.30.30.3
0.0350.0400.0500.0500.0500.0600.0600.0700.0700.0700.080
0.891.021.271.271.271.521.521.781.781.782.03
0.2080.3170.3830.4540.5060.5880.6080.6710.7060.8411.132
1121426384
105126167188250519
5.288.049.74
11.5412.8414.9415.4417.0417.9421.3628.76
16316294
125157187249280372773
3476
130186241319359456508707
1382
50113193277358475534678756
10522056
www.2mkablo.com13
300V Instrumentation Cables
300V 105°C PVC Insulated,Unshielded Pairs with Overall ShieldITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer)Overall shield : Plastic coated aluminum tape in contact with tinned copper drain wire.Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250
Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft)Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil Resistance
:: :: : : ::::::
:
300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 ( VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)
www.2mkablo.com 14
300V Instrumentation Cables
*14/7
*16/7
*18/7
12468101216182450
12468101216182450
12468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.510.510.510.510.510.510.510.510.510.510.51
0.380.380.380.380.380.380.380.380.380.380.38
0.380.380.380.380.380.380.380.380.380.380.38
0.0400.0500.0600.0600.0700.0700.0700.0700.0800.0800.090
0.0350.0500.0500.0600.0600.0600.0700.0700.0700.0800.090
0.0350.0500.0500.0500.0600.0600.0600.0700.0700.0700.080
1.021.271.521.521.781.781.781.782.032.032.29
0.891.271.271.521.521.521.781.781.782.032.29
0.891.271.271.271.521.521.521.781.781.782.03
0.3170.4820.5760.6870.7900.8920.9201.0221.0971.2821.739
0.2590.4030.4660.5720.6390.7180.7620.8450.8881.0541.420
0.2350.3640.4190.4940.5720.6390.6630.7500.7900.9161.239
2956
113167223279335447503669
1394
183671
107142177212282318424882
1223466789
111134177200265552
8.0412.2414.6417.4420.0622.6623.3625.9627.8632.5644.18
6.5810.2411.8414.5416.2418.2419.3621.4622.5626.7636.08
5.989.24
10.6412.5414.5416.2416.8419.0620.0623.2631.46
4384
168249332415499665748996
2074
2754
105159211263316420473631
1312
183468
100132165199264297395821
86188312454605767863
1106126617083360
56128200303388489570726812
11172177
4499
151214289362407536597799
1558
128280465676901
114112841646188425425000
83191298451577727848
1080120816633239
65148224319430538606798889
11892318
www.2mkablo.com15
300V Instrumentation Cables
*20/7
12468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012
0.30.30.30.30.30.30.30.30.30.30.3
0.0350.0400.0500.0500.0500.0600.0600.0700.0600.0700.070
0.891.021.271.271.271.521.521.781.521.781.78
0.2040.2930.3520.4110.4580.5330.5490.6040.6350.7540.994
8152842566983
111125167346
5.187.448.94
10.4411.6413.5413.9415.3416.1419.1625.26
1222426283
103124165186248515
3263
105144183245271343382529995
4794
156215272365404511569787
1480
www.2mkablo.com 16
300V Instrumentation Cables
300V 105°C PVC Insulated,Unshielded Triads with Overall ShieldITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer)Overall Shield : Plastic coated aluminum tape in contactwith tinned copper drain wire Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250
Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil ResistanceSunlight Resistance
:: :: : : ::::
:
::
300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200
www.2mkablo.com17
300V Instrumentation Cables
*14/7
*16/7
*18/7
12468101216182450
12468101216182450
12468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015
0.510.510.510.510.510.510.510.510.510.510.51
0.380.380.380.380.380.380.380.380.380.380.38
0.380.380.380.380.380.380.380.380.380.380.38
0.0400.0500.0600.0700.0700.0700.0700.0800.0800.0900.090
0.0400.0500.0500.0600.0600.0700.0700.0700.0700.0800.090
0.0350.0500.0500.0600.0600.0600.0600.0700.0700.0700.080
1.021.271.521.781.781.781.782.032.032.292.29
1.021.271.271.521.521.781.781.781.782.032.29
0.891.271.271.521.521.521.521.781.781.782.03
0.3320.5330.6390.7860.8840.9981.0341.1681.2311.4641.964
0.2850.4460.5170.6350.7140.8250.8530.9430.9941.1831.602
0.2470.4030.4620.5690.6350.7140.7380.8370.8841.0301.392
4284
167251335419503669754
10052091
2754
107159213265319424477635
1322
173467
101134167200265298398827
8.4413.5416.2419.9622.4625.3626.2629.6631.2637.1849.88
7.2411.3413.1416.1418.1420.9621.6623.9625.2630.0640.68
6.2810.2411.7414.4416.1418.1418.7421.2622.4626.1635.36
63125249374499623748996
112214953112
4080
159237317395474631710945
1967
255099
150199248297395444592
1230
109251423642828
105011931562175024034688
75170271411528691781
1001111915373022
54128200305390491553730813
10962151
162373629955
1232156317762324260535766976
111253403612786
102811631490166522884497
80190298454580730823
1086121016313201
www.2mkablo.com 18
300V Instrumentation Cables
*20/7
12468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012
0.30.30.30.30.30.30.30.30.30.30.3
0.0350.0400.0500.0500.0500.0600.0600.0600.0600.0700.080
0.891.021.271.271.271.521.521.521.521.782.03
0.2120.3200.3870.4580.5090.5920.6120.6750.7100.8451.136
1121426284
105125167188249519
5.388.149.84
11.6412.9415.0415.5417.1418.0421.4628.86
16316293
125156186248280371773
3882
136193248327368465516719
1394
57122202287369487547692768
10702075
www.2mkablo.com19
300V Instrumentation Cables
300V 105°C PVC Insulated,Individual Pairs with Overall ShieldITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3)Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Individual Shield : Plastic coated aluminum tape in contact with tinned copper drain wire.Separator : Polyester tape (at least 1 layer)Overall shield : Plastic coated aluminum tape in contactwith tinned copper drain wire.Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250
Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft)Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil Resistance
:: :: : : ::::::
:
300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)
www.2mkablo.com 20
300V Instrumentation Cables
*14/7
*16/7
*18/7
246101218202450
246101218202450
246101218202450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0,0200,0200,0200,0200,0200,0200,0200,0200,020
0,0150,0150,0150,0150,0150,0150,0150,0150,015
0,0150,0150,0150,0150,0150,0150,0150,0150,015
0,510,510,510,510,510,510,510,510,51
0,380,380,380,380,380,380,380,380,38
0,380,380,380,380,380,380,380,380,38
0,0500,0600,0600,0700,0700,0700,0800,0800,090
0,0500,0500,0600,0600,0600,0700,0700,0800,090
0,0500,0500,0500,0600,0600,0700,0700,0700,080
1,271,521,521,781,781,782,032,032,29
1,271,271,521,521,521,781,782,032,29
1,271,271,271,521,521,781,781,782,03
0,5290,6350,7610,9911,0261,1991,2901,4311,944
0,4460,5130,6350,8010,8280,9911,0461,1801,594
0,4030,4660,5530,7180,7420,8840,9351,0341,400
56112167279335503558670
1394
3671
106177212318353424882
224467
110132198220265550
13,4416,1419,3425,1626,0630,4632,7636,3649,38
11,3413,0416,1420,3421,0425,1626,5629,9640,48
10,2411,8414,0418,2418,8422,4623,7626,2635,56
83166249415498748831997
2075
53105158263316473526631
1312
336699
164197295328394819
218362527897
10071445164319953926
152238357585658968
107513322605
119182261445498732810983
1920
324538785
133514992151244529695842
226354532870979
1441160019823876
177271389662741
1089120614632857
www.2mkablo.com21
300V Instrumentation Cables
*20/7
246101218202450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0,0120,0120,0120,0120,0120,0120,0120,0120,012
0,30,30,30,30,30,30,30,30,3
0,0400,0500,0500,0600,0600,0600,0700,0700,070
1,021,271,271,521,521,521,781,781,78
0,3280,3950,4660,6080,6240,7260,9351,0261,144
1428426984
125139167346
8,3410,0411,8415,4415,8418,4423,7626,0629,06
214262
103125186207248515
79130185312348490548682
1297
117194275464518729815
10151930
www.2mkablo.com 22
300V Instrumentation Cables
300V 105°C PVC Insulated, Individual Triadswith Overall Shield ITC/PLTC
Construction
Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3 ) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Individual Shield : Plastic coated aluminum tape in contact with tinned copper drain wire. Separator : Polyester tape (at least 1 layer)Overall Shield : Plastic coated aluminum tape in contactwith tinned copper drain wire. Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C)colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250 Technical and Electrical Properties (20 °C)
Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests
Oil ResistanceSunlight Resistance
:: :: : : ::::
:
::
300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200
www.2mkablo.com23
300V Instrumentation Cables
*14/7
*16/7
*18/7
2468101216182450
2468101216182450
24681012182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0,0200,0200,0200,0200,0200,0200,0200,0200,0200,020
0,0150,0150,0150,0150,0150,0150,0150,0150,0150,015
0,0150,0150,0150,0150,0150,0150,0150,0150,015
0,510,510,510,510,510,510,510,510,510,51
0,380,380,380,380,380,380,380,380,380,38
0,380,380,380,380,380,380,380,380,38
0,0500,0600,0600,0700,0700,0700,0700,0800,0800,090
0,0500,0500,0600,0600,0600,0700,0700,0700,0800,090
0,0500,0500,0500,0600,0600,0600,0700,0700,080
1,271,521,521,781,781,781,782,032,032,29
1,271,271,521,521,521,781,781,782,032,29
1,271,271,271,521,521,521,781,782,03
0,5840,6980,8400,9671,0971,1361,2621,3531,5892,168
0,4940,5720,7060,7930,8990,9511,0541,1131,3251,798
0,4430,5090,6080,7020,7970,8200,9831,1481,561
84167251335419503669753
10052090
53106159212264318423476634
1321
3467
100133165199298397827
14,8417,7421,3424,5627,8628,8632,0634,3640,3655,08
12,5414,5417,9420,1422,8424,1626,7628,2633,6645,68
11,2412,9415,4417,8420,2420,8424,9629,1639,66
125249374499623748996
112114953111
79158236315393473630708944
1966
5099
149198246296443591
1230
288482710948
120413641753199927135369
196312474612779906
1161130017883516
155239347468591665976
13252595
429718
10561411179220302609297540387990
291465706911
116013491728193526615233
230355516696879990
145319723862
www.2mkablo.com 24
300V Instrumentation Cables
*20/7
2468101216182450
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGTriad
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
0,0120,0120,0120,0120,0120,0120,0120,0120,0120,012
0,30,30,30,30,30,30,30,30,30,3
0,0400,0500,0500,0500,0600,0600,0600,0600,0700,070
1,021,271,271,271,521,521,521,521,781,78
0,3560,4310,5090,5690,6630,6830,7571,0380,9511,262
21426383
104124166187249519
9,0410,9412,9414,4416,8417,3419,2426,3624,1632,06
316294
124155185247278370772
100167241309405455578646899
1723
149249359460602677860962
13382564
www.2mkablo.com27
600V Instrumentation Cables
600V, PVC/Nylon Insulated, 90°CType TC – UL 1277 – NEC ART 336
ApplicationsThe 600V Instrumentation Cables are listed as Type TC per UL 1277. Suitable for installations as described in NEC ART 336.Construction ConductorBare, annealed copper conforming to ASTM B-3 and Class B stranded in accordance to ASTM B-8.InsulationPVC/Nylon Type Flame retardant, 90°C temperature rating.Insulation Shield (Shielded pair/triad constructions)Aluminum foil/polyester shield helically wrapped to provide 100 % coverage with a tinned copper drain wire that is two gaugesizes smaller than the circuit conductorsJacketUL listed sunlight and moisture resistant, sequentially length marked, black, flame retardant polyvinyl chloride material. A Nylon ripcord can be included for ease of jacket removal.Features• UL approved Type TC, 600V• UL approved insulated conductors• UL 1685 and IEEE 383 vertical fire tests at 70,000 BTU/hr• Temperature rating 90°C dry• Sunlight and moisture resistant jacket• For use within Class 1 Division 2 and Class 2 Division 2 Hazardous Locations and Intrinsically Safe applications as permitted by NEC ART 392, 501, 502, 504 and 505.• Cables are rated for Direct Burial applications• For use in cable trays, raceways, conduit or for aerial applications where installed with a messenger• Cables may be used In Class 1 Circuits, as defined in NEC Section 336.10 and ART 725 for Type TC cables• The Nylon jacket provides excellent oil and gasoline protection.Specifications• UL 1277 Rated 90°C / 600V• UL requirements for Type TC• Designated Type TC per NEC ART 336
www.2mkablo.com 28
600V Instrumentation Cables
600V PVC/Nylon/PVCOverall Shielded Pairs/Triads TC-ER Rated
Construction
Conductor : Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B-8 IEC/EN 228, HD 383, BS 6360, VDE 0295)Insulation : Heat resistant PVC (UL 1581 class 90°C, EN 50363-3 TI3) with clear Polyamide (Nylon) Separator : Polyester tape (at least 1 layer)Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc.Shield : AL-PES foil, Aluminum contact with stranded tinnedcopper drain wire Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 90°C)Reference Standard : UL 1277
Technical and Electrical Properties (20 °C)
Max. Operating Voltage Conductor Resistance (Ω/kft)Insulation Thickness (mils)
Min. Bending Radius (fixed) Temperature RateOxygen Index Flame Tests
Oil Resistance
:: :
::::
:
600V AWG 16: 14.3 (4.36 Ω/kft) AWG 18: 22.7 (6.95 Ω/kft) AWG 16: 0.39 mils PVC + 0.12 mm NylonAWG 18: 15.36 mils PVC + 4.73 mils Nylon7.5 x Cable DiameterDry: 90°CMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)
www.2mkablo.com29
600V Instrumentation Cables
11 TRI
23457121620243650
11 TRI
23457121620243650
*16/7
*18/7
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.510.510.510.510.510.510.510.510.510.510.510.510.51
0.510.510.510.510.510.510.510.510.510.510.510.510.51
0.0450.0450.0450.0450.0600.0600.0600.0600.0800.0800.0800.0800.080
0.0450.0450.0450.0450.0450.0600.0600.0600.0800.0800.0800.0800.080
1.141.141.141.141.521.521.521.522.032.032.032.032.03
1.141.141.141.141.141.521.521.522.032.032.032.032.03
0.2680.4610.4330.4610.5350.5830.6300.8230.9531.0551.1651.3311.555
0.2800.2950.3940.4170.4530.5280.5710.7360.8540.9451.0431.1891.382
182635527088
123211281352422633880
11 16 22 33 44 55 77
132 176 220 264 396 550
6.811.7
1111.713.614.8
1620.924.226.829.633.839.5
7.17.5
10.0010.6011.5013.4014.5018.7021.7024.0026.5030.2035.10
26395279
105131183314419524628943
1310
162533496682
115197262328393590819
56 87 97
123 169 199 254 400 548 662 776
10911464
46557493
113151189294406488570790
1052
83131145184252297378596816986
115616252180
6983
111139168225282438606727849
11761567
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
www.2mkablo.com 30
600V Instrumentation Cables
600V PVC/Nylon/PVCIndividual and Overall Shielded PairsTC-ER Rated
Construction
Conductor : Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B-8 IEC/EN 228, HD 383, BS 6360, VDE 0295)Insulation : Heat resistant PVC (UL 1581 class 90°C, EN 50363-3 TI3) with clear Polyamide (Nylon) Individual Separator : Polyester tapeIndividual Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc.Individual Shield : AL-PES foil, Aluminum contact with strandedtinned copper drain wire General Separator : Polyester tape (at least 1 layer)General Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc. General Shield : AL-PES foil, Aluminum contact with strandedtinned copper drain wire Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 90°C)Technical and Electrical Properties (20 °C)
Max. Operating Voltage Conductor Resistance (Ω/kft)Insulation Thickness (mils)
Min. Bending Radius (fixed) Temperature RateOxygen Index Flame Tests
Oil Resistance
:: :
::::
:
600VAWG 16: 14.3 (4.36 Ω/kft) AWG 18: 22.7 (6.95 Ω/kft) AWG 16: 0.39 mm PVC + 0.12 mm. NylonAWG 18: 15.36 mils PVC + 4.73 mils Nylon7.5 x Cable diameterDry: 90°C Min. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1, IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)
www.2mkablo.com31
600V Instrumentation Cables
234578121620243650
23457121620243650
*16/7
*18/7
Min. AVGInsulation Thickness
Min. AVGJacket Thickness Nominal O.D.Conductor
AWGPair
NumberApproximate
Copper WeightApproximateCable Weight
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020
0.510.510.510.510.510.510.510.510.510.510.510.51
0.510.510.510.510.510.510.510.510.510.510.51
0.040.040.040.060.060.060.060.080.080.080.080.08
0.040.040.040.060.060.060.080.080.080.080.08
1.141.141.141.521.521.521.522.032.032.032.032.03
1.141.141.141.521.521.522.032.032.032.032.03
0.490.520.570.660.710.800.931.081.201.331.521.78
0.440.470.510.590.640.830.961.071.201.351.58
35537088
123141211282352422634880
2233445577
132176220264396550
12.3813.1814.4816.6418.0420.2423.7427.4630.4633.7638.6645.26
11.1811.8812.9814.9416.2421.1424.4627.1630.4634.3640.06
5279
105131183210314419524628943
1310
33496682
115197262328393590819
154199252323418496714956
1187143820362816
115147
183.90238
305.80520698867
104714772036
230296374481622737
106314231766214030304191
171219274355455774
10391290155821983029
Inches(mm)
(±0.02) Inches(mm)
(±0.05) Inches(mm)(±%5)
(kg/km)(±%5)
(kg/km)(±%5)
LBS/1000 FT
LBS/1000 FT
NOTICE2M CABLE ensures the accuracy of the all data in this publication,however we cannot be liable for the consequences of errors or omissions.The installer and/or user assumes all liability for the consequencesof the installation and/or use of any of our products in contraventionof any applicable law, regulation or code.
Instrumentation Cables