    1/6

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R

    Applications Typical applications include:

    Pulp and paper mills Processing plants Chemical plants Oil re neries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust, water, dirt and rough usage are a

    problem

    Features Compact in size, attractively styled contemporary design,

    rugged and dependable. Easy to install and service. One-piece housing. One-piece lens hinged cover. Secured by four M6 captive

    stainless steel slotted hex-head bolts. Thermal shock and impact resistant glass lens. Heavy duty, high temperature silicone rubber gasket,

    mechanically secured. Universal design for ood and highbay mounting Floodlight Mounting:

    Yoke mount, zinc plated steel yoke with architectural bronzepolyester nish.

    High Bay Mounting: (1) Conduit entry on back of luminaire with locking set screw. Rotate yoke up or remove.

    Vibration rated in all con gurations. Cool operating temperatures translate into long luminaire life. Total of three (3) 3/4" NPT entries with integral bushings. Two (2) aluminum close up plugs provided. Electrical: 120-277 Vac, 50/60 Hz; 347 480 Vac, 50/60 Hz Terminal block (screw type for secure connection) can accept

    24-10 AWG wire.

    Standard Materials Ballast housing and lens door: aluminum Gasket: silicone rubber Re ector: polymaris metallized high re ectance nish Yoke mount: zinc plated steel Bolts: stainless steel Plugs: (2) aluminum provided Tempered glass lens Locking set screw: stainless steel

    Standard Finishes Housing, lens cover and yoke mount: architectural bronze

    polyester

    Certifications and Compliances NEC/CEC

    UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 CSA Standards: C22.2 No. 250.0, C22.2 No. 137 cULus

    Floodlight

    High Bay

    1155 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

  • 8/14/2019 Areamaster_LED_Flood_Highbay_Series.pdf

    2/6

    Electrical Specifications

    Voltage Suffix

    Voltage Range Watts -Input Power (Nom.)

    Input Amps(Max.)

    Total HarmonicDistortion Power FactorVac Hz

    BU 120 - 277 50/60 127 1.40 - 0.60 5% - 10% > 0.90

    BH 347 - 480 50/60 127 0.50 - 0.35 7.5% - 9% > 0.90

    T Numbers

    Supply Wire Temp.(F/C)

    Ambient Temp.(F/C)

    NEC/CEC

    LampClass I, Division 2,Groups A, B, C, D

    LED 140/60 104/40 T4

    T Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations

    T

    Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6Temp.Range

    (F)

    664-842

    619-662

    574-617

    538-572

    502-536

    448-500

    421-446

    394-419

    358-392

    331-356

    322-329

    277-320

    250-275

    214-248

    187-212 185

    Temp.Range

    (C)

    351-450

    326-350

    301-325

    281-300

    261-280

    231-260

    216-230

    201-215

    181-200

    166-180

    161-165

    136-160

    121-135

    101-120

    86-100 85

    L i g h t i n g

    LGHTNG:

    ENCLO

    EDANDGA

    KETED

    FLOODLGHT

    1156 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R

  • 8/14/2019 Areamaster_LED_Flood_Highbay_Series.pdf

    3/6

    Line VoltageFor Class I, Division 2 Classified Duty and Marine Yoke Mount

    Catalog Number

    120-27750/60 Hz AMLED77YBU

    347-48050/60 Hz AMLED77YBH

    Accessories

    Description Catalog Numbers

    Crossarm Mounting Bracket

    Has 180 horizontal adjustment degree marked. Facilitates mountingfloodlight to crossarm or other flat surface, or to G-AM-8-WB. Includesfloodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,architectural bronze polyester finish.

    G-AM-8-CA

    Pipe or Wall Mount Bracket

    Used with G-AM-8-CA. Clamps to 1 to 2-1/2 pipe, vertical or horizontal,or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.Malleable iron, zinc plated, chromate sealed, with architectural bronze polysterfinish.

    G-AM-8-WB

    Poletop Slip-Fitter

    Slip-fits 1-1/2 or 2 pipe size poletop tenons. Includes floodlight yoke bolts,3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromatesealed, with cast aluminum cap. Assembly has architectural bronze polyesterfinish.

    G-SF20

    Poletop Slip-Fitter

    Slip-fits 2 or 2-1/2 poletop tenons. Includes floodlight yoke bolts, 3 lockingbolts, and cord grip. Malleable iron, zinc plated, chromate sealed, witharchitectural bronze polyester finish.

    G-AM-8-SF

    1157 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R

  • 8/14/2019 Areamaster_LED_Flood_Highbay_Series.pdf

    4/6

    Dimensions in Inches/MillimetersFloodlight

    High Bay Pendant Mount

    12 in./ 304.8 mm

    6 in./ 152.4 mm

    Required MinimumMounting Distance

    Ceiling

    Jct BoxSet Screw

    Rotate YokeUp or Remove

    15.30 in./388.6 mm

    (4) Yoke Bolts

    ConduitEntry

    ConduitEntry(PendantMount)

    Yoke

    (3) Mounting Holes0.56 Dia.

    3.64 Turning Radius180 Rotation

    (3) hubs for 3/4" NPT ConduitGround Terminal

    SetScrew

    14.10 in./ 358.1 mm

    5.70 in./ 144.78 mm

    3.50 in./ 88.9 mm

    4.83 in./ 122.7 mm

    7.20 in 2 / 4645.2 mm 2

    15.40 in./ 391.2 mm

    3.70 in./93.9 mm

    3.50 in./88.9 mm

    2.25 in./ 57.2 mm

    1.75 in./ 44.45 mm

    Areamaster LED Weight

    Description Weight in Lbs/Kg

    Fixture Unit 22.00/10.0

    L i g h t i n g

    LGHTNG:

    ENCLO

    EDANDGA

    KETED

    FLOODLGHT

    1158 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R

  • 8/14/2019 Areamaster_LED_Flood_Highbay_Series.pdf

    5/6

    Axial CandelaDegree Horizontal Degree Vertical

    90 0 90 085 24 85 375 35 75 5765 803 65 69055 2179 55 2348

    47.5 3011 47.5 301742.5 3457 42.5 337137.5 3969 37.5 391633 4390 33 443229 4697 29 4785

    25.5 4714 25.5 4992

    22.5 4765 22.5 493219.5 4619 19.5 472617 4514 17 445215 4435 15 435013 4338 13 426211 4241 11 42149 4201 9 41837 4199 7 41985 4186 5 42073 4186 3 42121 4205 1 42120 4210 0 4210

    -1 4208-3 4196

    -5 4179-7 4183-9 4198

    -11 4234-13 4262-15 4334-17 4507

    -19.5 4733-22.5 4925-25.5 4929-29 4681-33 4357

    -37.5 3845-42.5 3319-47.5 2970-55 2299-65 648-75 7-85 3-90 0

    FloodlightLuminaire Lumens = 13138Mounting Height = 12.00 ft, Tilt = 45Maximum Calculated Value = 25 FcTypical Footcandle Values

    FloodlightLuminaire Lumens = 13138Mounting Height = 20.00 ft, Tilt = 45Maximum Calculated Value = 10 FcTypical Footcandle Values

    20100

    Distance

    infeet

    Distance in feet

    footcandles (fc)

    .1 fc

    1 fc

    2 fc

    2 fc

    5 fc

    10 fc20 fc

    .5 fc

    0

    -10

    -10

    Distance infeet

    Distance in feet

    200

    footcandles (fc)

    1 fc

    2 fc

    2 fc

    .5 fc

    5 fc

    10 fc

    0

    -10

    -10

    -20

    -20

    1159 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R

  • 8/14/2019 Areamaster_LED_Flood_Highbay_Series.pdf

    6/6

    High Bay CIE Type - General DiffuseLuminaire Lumens = 13211

    Polar Graph - High Bay

    Coefficients of Utilization - Zonal Cavity Method

    Effective Floor Cavity Reflectance 0.20

    Rcc 80 70 50 30 10 0

    Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

    Zonal Lumen Summary 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100

    Zone Lumens % Fixture 1 111 107 103 100 108 105 102 99 101 98 96 97 95 93 93 91 90 88

    0-30 3849 29.1 2 102 95 89 84 100 93 88 83 90 85 81 86 83 79 83 80 78 76

    0-40 6804 51.2 3 94 84 77 71 91 83 76 71 80 74 69 77 72 68 75 71 67 65

    0-60 12051 91.2 4 86 75 67 61 84 74 66 61 71 65 60 69 63 59 67 62 58 56

    0-90 13196 99.9 5 79 67 59 53 77 66 58 52 64 57 52 62 56 51 60 55 51 49

    90-120 4 0.00 6 73 60 52 46 71 60 52 46 58 51 45 56 50 45 55 49 45 43

    90-130 6 0.1 7 68 55 46 41 66 54 46 40 52 45 40 51 45 40 50 44 39 38

    90-150 11 0.1 8 63 50 42 36 61 49 41 36 48 41 36 47 40 35 45 40 35 33

    90-180 14 0.1 9 59 46 38 32 57 45 37 32 44 37 32 43 36 32 42 36 32 30

    0-180 13211 100.0 10 55 42 34 29 54 41 34 29 40 34 29 39 33 29 39 33 29 27

    4500

    3000

    1500

    L i g h t i n g

    LGHTNG:

    ENCLO

    EDANDGA

    KETED

    FLOODLGHT

    1160 Visit our website at www.appletonelec.com or contact us at (800) 621-1506 . February 2012

    Areamaster LED Flood/High Bay Luminaires

    NEC/CEC:Class I, Division 2, A, B, C, D

    Marine Outside Type (Salt Water)Wet LocationsType 4 and 3R