Ardrox 2320-(Data Sheet).

download Ardrox 2320-(Data Sheet).

of 2

Transcript of Ardrox 2320-(Data Sheet).

  • 8/10/2019 Ardrox 2320-(Data Sheet).

    1/2

    Ardrox2320Immersion/spray paint remover

    Scope

    ARDROX 2320 is a di-phase aqueous blend of solvent, activators and corrosion inhibitor.

    ARDROX 2320 will remove a variety of organic finishes.

    Chemicals required

    ARDROX 2320A

    ARDROX 2320B

    Method of use

    Half fill the stripping tank with demineralised water. Add 10% v/v, of the operating volume,ARDROX 2320A. Add 5% v/v of ARDROX 2320B. Thoroughly agitate. Fill the tank to its operating levelwith demineralised water and thoroughly agitate the contents of tank.

    Immersion

    Components to be stripped are immersed in the bath for periods generally up to 4 hours at temperaturesfrom ambient to 55C depending on the nature of the coating. The bath should be agitated while the

    components are in the tank. The components are then pressure water rinsed.

    Spray

    Components should be left in the spray machine for periods generally up to one hour at temperatures ofambient to 55C. If possible a two-stage spray machine should be used so the components can be waterrinsed within the spray machine. If this is not possible the components should be pressure rinsed outsidethe cabinet.

    Dry the components thoroughly using compressed air or an air recirculation oven at 60 - 80C.

    NOTE Ardrox 2320 can be used at higher temperatures on non-critical components that are notsusceptible to hydrogen embrittlement.

    Method of control

    The pH of the water phase (top phase) of the bath should be maintained within the range 12.-12.5. Toraise the pH of the bath add ARDROX 2320B in measured increments until within the desired range.

    The lower phase of the bath (ARDROX 2320A) should be maintained within the range 5-15% v/v. Thismay be measured by taking a representative sample of the tank contents, placing in a measuringcylinder and allow to stand. If the lower separated phase is below the desired range add ARDROX2320A, if above the range add demineralised water.

    Any water added to the tank to correct for evaporation should be demineralised water.

  • 8/10/2019 Ardrox 2320-(Data Sheet).

    2/2

    Page 2/2

    Ardrox 2320

    registered trademark

    The above data have been compiled to the best of our knowledge on the basis ofthorough tests and with regard to the current state of our long practical experience. No

    liabilities or guarantee deriving from or in connection with this leaflet can be imputed to us.

    Reproduction, in whole or in part, only with our express permission.

    Effects on materials

    Will not affect most common metals, e.g steel, zinc, aluminium, copper. Polymeric materials, such as

    Perspex/Plexiglas (polymethylmethacrylate) and PVC, and some rubbers will be affected.

    Technical information

    ARDROX 2320A ARDROX 2320B

    Appearance: Colourless liquid Colourless liquid

    Density: 1.04 g/ml 1.18 g/ml

    Flash Point: 96C Not applicable

    These are typical values and do not constitute a specification.

    When operated in accordance with the requirements contained in this Technical Data Sheet Ardrox 2320will conform to the requirements of AMS 1375B and Boeing D6-17487.

    Equipment materials

    Equipment/tanks should be constructed of 316 or 320 stainless steel.

    Safety guidance

    Before operating the process described it is important that this complete document, together with anyrelevant Safety Data sheets, be read and understood.

    General information

    Chemetall PLC supplies a wide range of chemical products and associated equipment for cleaning,sanitising, descaling, paint and carbon removal, metal protection and non-destructive testing. SalesExecutives are available to advise on specific problems and applications.

    Labour and environmental protection

    All local and national regulations on the transport, storage, use and waste treatment of chemicals inconcentrated or diluted form and as working solutions must be obeyed.

    Further specific information on the products can be found in the EC Safety Data Sheets supplied. Theuser should also pay strict attention to information and hazard symbols shown on product labels.

    Waste disposal

    All waste waters must be treated in accordance with national legislation and local regulations prior todischarge to the sewer.

    mec Apr 2002