Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit...

6
Architectural Specification TAP 200 Secure Entry Portal Section 08 42 33 – Security Doors PART I – GENERAL 1.01 SECTION INCLUDES A. This section covers the furnishing and installation of a complete Automatic Secure Entry Portal System.

Transcript of Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit...

Page 1: Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours. OPERATION

Architectural Specification

TAP 200 Secure Entry PortalSection 08 42 33 – Security Doors

PART I – GENERAL

1.01 SECTION INCLUDESA. This section covers the furnishing and installation of a complete Automatic Secure Entry Portal

System.B. Provide complete system that has been fabricated, assembled, and tested for proper operation

at the factory. It includes curved side walls, canopy, ceiling, door wings, glass, motor drive systems, and security system as required for installation.

Page 2: Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours. OPERATION

1.02 RELATED SECTIONSA. Section 07915 - Sealants, Caulking and SealsB. Section 08400 - Entrances and StorefrontsC. Section 08710 - Door HardwareD. Section 08810 - Glass and GlazingE. Section 09600 - FlooringF. Section 16123 - Electrical Supply and TerminationG. Section ( ) - Security System

1.03 QUALITY ASSURANCEA. Manufacturer shall be a company specializing in the supply of automatic security doors with a

minimum of 10 years experience.

1.04 SUBMITTALSA. Submit project specific shop drawings and finish samples.B. Indicate pertinent dimensions, general construction, component connections and locations,

anchorage methods and locations, hardware, and installation details.

1.05 DELIVERY, STORAGE AND HANDLINGA. Deliver materials to job site in manufacturer’s packaging undamaged, complete with installation

instructions.B. Store off ground, under cover, protected from weather and construction activities.

1.06 PROJECT/SITE CONDITIONSA. Install security portal below finished floor. Floor must be dead level at any point within the

footprint of the Portal.

1.07 WARRANTYBoon Edam warranties its products against defects in material and workmanship for a period of twelve (12) months from the date of shipment of the product. This warranty excludes glass breakage, normal wear on finishes or damage that occurs due to abuse, misuse or acts of God.

Page 3: Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours. OPERATION

PART II – PRODUCTS

2.01 MANUFACTURERSecurity Entrance Portal Model - TAP 200 shall be furnished by Boon Edam, Inc. as an exclusive distributor of Alluser Products.

2.02 DOOR CONSTRUCTIONA. The interlocking door system equipment shall be comprised of two curved sliding door leaves

with optional bi-parting leaves within a glazed drum. B. The curved door leaves shall be constructed with laminated glass as a standard.

2.03 EQUIPMENTA. Operator : shall be mounted and concealed within the header. Operating force shall be

accomplished through two1/8 HP, 24VDC motors with 260 RPM working with a left and right trolley arm kit and cabin trolley shaft made of induction hardened steel; a solid-state master controller mother board; integral trolley stroke end kit and motor potentiometer kit. The operator shall fail-secure when power is removed.

B. Solid-State Voice Synthesis Circuit : shall be provided. Tape recorded messages shall not be accepted.

C. Emergency Release Device : Shall be located inside header and when manually operated, unit reverts to free manual operation (likewise during electrical power failure). The non-secure side door shall be the only door affected by this device.

D. Integral Battery Back-up : The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours.

2.04 OPERATION A. Operation: The unit shall incorporate interlocking door leaves to make certain security is

maintained and a clear opening is never presented. In normal operation, the unit shall always keep the non-secure side door leaf closed and the secure side door leaf locked to maintain optimum security. The first door shall be activated by means of an access control device (supplied by the access control contractor). The person requesting entry shall enter the cabin and shall not be granted further passage until the internal security system confirms security criteria are met and that only one person has entered the cabin. The second door shall open immediately once the person has been authorized. In the event that any of the security sensors are activated, an alarm shall sound at the security guard post and the unit shall prevent further progress.

2.05 SECURITY FUNCTION A. Access Control: The portal shall accommodate electronic access control card readers and

biometric devices (supplied by others) to allow authorized passage. Optional identity verification access control devices can be mounted inside the portal in an optional alcove. A special mounting bracket concealed behind a protective Lexan lid shall accommodate the installation of the optional internal access control device. After the optional internal access control device authorizes passage, the interior portal door will open into the secured area. Any attempt of unauthorized passage shall result in the interior secure side door not opening. A solid-state voice annunciator shall advise the individual of the infraction and advise them to exit the cabin. The exterior (first) door can then be opened to allow the individual to exit the cabin.

B. A.P.D Anti-Piggybacking Detection: The A.P.D. is an ultrasonic sensor system with a two zone floor contact mat that scans the interior of the cabin and determines if more than one person is attempting passage. If piggybacking is detected, the passage is not authorized and the individuals must exit the cabin through the exterior (first) door as described in 2.05.A above.

C. Attempted Passage: Any attempt of passage by unauthorized individuals into the controlled area shall prevent the interior secure side door from opening and a solid state voice annunciator shall advise the person who committed the infraction to exit the cabin. Systems consisting of pre-recorded tape messages shall not be accepted. The exterior door shall unlock allowing the person to exit the cabin on the ingress side.

Page 4: Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours. OPERATION

D. Metal Detection: Available option. CEIA model 02PN8 Metal Detector. It is extremely important that the structure of the portal is well fixed for metal detector applications; structure vibrations can create field metal detector variations. The metal detector is configured to the NileCJ/STG/0601AM7 setting (e.g. Beretta Model 950 B Calibre 6.35 in light alloy).

2.06 SAFETYA. Emergency Door Control : The unit shall be equipped with a manual release for opening the

exterior non- secure door in the event of mechanical failure or emergency. The manual release shall be located inside the cabin and clearly marked with a red handle. Activating this device shall not allow the interior secure door to be opened and shall render the unit ineffective until the handle is returned to the normal position.

B. Intercom : The unit shall include an intercom as a standard feature. Communication between the person inside the cabin and the intercom master station shall be accomplished by depressing a single button on the intercom located inside the cabin. The intercom shall be an integral part of the Control Panel and shall function even when the control panel is switched off. An optional intercom can be added to facilitate remote monitoring of the cabin.

C. Dry Contact Input : The unit shall supply a set of contacts which, when activated by the building's fire detection or suppression systems, both doors shall open immediate.

2.07 HARDWARE/MATERIALSA. Laminated Glass : .10mm clear curved laminated safety glass is standard. All glass shall meet

ANSI standard Z 97.1.B. Vandal Resistant Glazing (Optional) : 13mmC. Bullet Resistant Glazing (Optional) : Bullet resistant glazing up to Level 3 is available as an

option.D. Aluminum Extrusions : All commercial grade extrusions shall be of aluminum alloy 6063-T6 per

ASTM B-221.E. Aluminum Sheets : Shall meet ASTM B-209 and be of .063 minimum thicknesses.F. Steel Plate, Shapes and Bars : Shall meet ASTM A 36/A 36MG. Steel Sheet : Shall meet ASTM A 1008/A 1008MH. Weather Stripping : Genuine mohair weather stripping on all required edges of door wings to

provide a seal between door wings and drum that meets ASTM E-283.

2.08 FINISHThe following finishes are available for the enclosure walls and canopy.

A. Painted Coatings 1. AAMA 2604 High Performance Organic Coatings (e.g.: Powder Coating). Please specify

RAL number.B. Stainless Steel Clad Type 304*

1. #4 Brushed Satin 2. #8 Highly Polished (mirror finish)

*Note: Except Door Wings

PART III – EXECUTION

3.01 INSTALLATIONA. Inspection : Installer must examine the location and advise the Contractor of any site conditions

unacceptable for proper installation of product. These conditions include but are not limited to the following:

1. Floor cutout not yet provided.2. Floor must be dead level at any point within the footprint of the Portal.3. Power supply must be installed.

Installation shall not begin until these unacceptable conditions are rectified.

Page 5: Architectural Specification - Boon Edam United … · Web viewIntegral Battery Back-up: The unit shall accommodate battery back-up to maintain continuous use for up to 2 hours. OPERATION

B. Erection : Install Security Portal in accordance with manufacturer’s printed instructions. Set units level, plumb, and with uniform hairline joints. Anchor securely into place. Use only factory trained installers.

C. Adjustment : Installer shall adjust Portal, hardware and sensors for smooth operation and proper performance.

D. Instruction : A factory-trained installer shall demonstrate to the owner’s maintenance crew the proper operation of the Portal and the necessary service requirements such as lubrication, cleaning, and inspection of components upon completion of installation.

E. Cleaning : Clean metal and glass surfaces carefully after installation to remove excess caulk, dirt and labels.

Boon Edam, Inc. reserves the right to change this specification at any time without notice.