USE OF ARCHITECTURAL DRAWINGS INDEX OF DRAWINGS BY DETAIL NUMBER GENERAL DETAILS
B26 Product Technical Data 3B27 Minimum Pitch Table 3B28 Rafter Length Table 4MT01 Sarked Ceiling - Exposed Rafters 4MT25 Fire Wall Detail 5
RIDGE DETAILS B12 Ridge Detail 5B13 Roof/Wall Ridge - Detail/Clerestorey 6MT02 Steep Pitched Ridge 6MT03 Butt Jointed Ridge 7 MT04 Flexible Pointing 7
BARGE DETAILS B05 Barge Tile Detail 8B06 Bed & Point Finish 8B07 Small Panel Metal Detail 9MT05 Barge Detail With Secret Gutter - Flat Tile 9MT06 Verge - Secret Gutter 10MT07 Verge - No Overhang Scribed Fillet 10MT08 Verge - No Overhang Concrete Block 11MT09 Flashing At Junction Of Metal Roof & Tile 11MT11 Barge Detail With Z Flashing - Flat Tile 12MT12 Barge Detail With Banbury Flashing - Flat Tile 12B30 Bed & Point Finish - Flat Tile 13
APRON DETAILS B01 Apron Details - Parallel Flashing Without Underlay 14B02 Apron Details - Parallel Flashing With Underlay 14B03 Apron Details - Transverse Flashing Without Underlay 15B04 Apron Details - Transverse Flashing With Underlay 15B25 Spreader For Roof Discharge 16B29 Kickout Flashing 16MT13 Stepped Cover Flashing 17MT14 Flashing To Brick Abutment 17MT15 Dutch Gable Detail 18MT16 Vertical Tiling 18
PITCH CHANGE DETAILS B08 Change In Pitch -35 Degrees Or Less 19B09 Change In Pitch - Greater Than 35 Degrees 19MT10 Mansard Detail 20
EAVES DETAILS B19 Timber Fascia Eaves Detail - Without Underlay 20B20 Timber Fascia Eaves Detail - With Underlay 21B21 Internal Fascia Gutter Detail 21B22 External Fascia Gutter Detail 22B23 Eaves Exposed Rafters 22B24 Eaves & Rafter Detail With Sarking 23MT23 Eaves Standard Gutter 23MT24 Fascia Height 24
VALLEY DETAILS B10 Valley Detail Without Underlay 24B11 Valley Detail With Underlay 25MT21 Hip Gutter 25MT22 Steep Pitch Roof Valley 26
PENETRATION DETAILS B14 Plan View Of Three Sided Penetration 26B15 Abutment Detail For Framed Penetration 27B16 Elevation/Section View Of Three Sided Penetration 27B17 Cross Section Of Hidden Gutter 28B18 Pipe Penetration Detail 28MT17 Cross Section Hidden Gutter - Flat Tile 29MT18 Chimney Tray 29MT19 Chimney Flashing 30MT20 Pipe Penetration Detail - Flat Tile 30
CONTENTS
1
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
USE OF ARCHITECTURAL DRAWINGSMonier roofing systems provide contemporary and innovative design solutions that benefit from the time proven effectiveness and sustainability of tiles. This manual contains a broad range of roofing details and applications enabling architects and specifiers to easily access and assess the suitability of design for their client.
MONIER DETAIL DRAWINGS NOW ONLINE
Monier roofing detail drawings are available in multiple CAD formats and as enlarged PDF files at monier.co.nz.
The information provided in the drawings provide reference information on the typical use of the Monier product. The information provided in this reference guide is generic innature; it does not contain the full details required for construction, nor does it constitute an express statement as to fitness for a particular purpose. Professional advice is required to take into account all site and design specific influences. Designers and specifiers will typically provide details specific to particular projects: these should always be referred to in preference to the default systemof drawings. The instructions and detailsavailable refer to both concrete and terracotta tiles (except where specifically noted).
MONIER COMPLIANCE WITH THENEW ZEALAND BUILDING CODE
When installed according to the manufacturers instructions, Monier products will meet theDurability performance requirements of NZBC B2 and E2.Methods used for verifying compliance with the relevant performances of the New ZealandBuilding Code, include testing and assessment by a laboratory, ease of installation assessment, assessment of data provided bythe manufacturer and the inservice history overseas and in New Zealand. Details areavailable from Monier.
IMPORTANT INFORMATION FORSPECIFICATION, PREPARATION& INSTALLATION
This manual has been prepared by Monier to assists the architect, builder and installer to specify, prepare and install roof tiles.While it is not possible to detail every condition that may be encountered, Monier will assist to advise on any special situationsthat may occur.This manual has been written as a working guide for industry, however it is not intended to replace good trade practice and experience essential to obtaining a quality roof installation. Nor does this manual overridespecific advice received from Monier fixing services.Architects and specifiers should ensure that the details provided in this manual are followed and determined to their ownsatisfaction that the job is complete to an acceptable standard of trade practice. Allcare has been taken in the compilation of this manual. However, Monier accepts noresponsibility or liability for the contents of the manual (including any printing or typographical errors) and recommends that all standards and recommendations are independently checked.
SPECIFICATIONS
While information contained in this manual is correct at the time of creation, specifications are subject to change without notice.
DISCLAIMER
This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specificapplication. Nothing in this information constitutes a statement of fitness for particularpurpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products.© 2010 The copyright of this document is the property of CSR Building Products (NZ) Ltd trading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.
MO
NIE
R A
RC
HIT
EC
TU
RA
L D
RA
WIN
GS
SE
CTI
ON
8
2
INDEX OF DRAWINGS BY DETAIL NUMBERDetail Category PageB01 Apron Details - Parallel Flashing Without Underlay Apron Details 14
B02 Apron Details - Parallel Flashing With Underlay Apron Details 14
B03 Apron Details - Transverse Flashing Without Underlay Apron Details 15
B04 Apron Details - Transverse Flashing With Underlay Apron Details 15
B05 Barge Tile Detail Barge Details 8
B06 Bed & Point Finish Barge Details 8
B07 Small Panel Metal Detail Barge Details 9
B08 Change In Pitch - 35 degrees Or Less Pitch Change Details 19
B09 Change In Pitch - Greater Than 35 Degrees Pitch Change Details 19
B10 Valley Detail Without Underlay Valley Details 24
B11 Valley Detail With Underlay Valley Details 25
B12 Ridge Detail Ridge Details 5
B13 Roof/Wall Ridge - Detail/Clerestorey Ridge Details 6
B14 Plan View Of Three Sided Penetration Penetration Details 26
B15 Abutment Detail For Framed Penetration Penetration Details 27
B16 Elevation/Section View Of Three Sided Penetration Penetration Details 27
B17 Cross Section Of Hidden Gutter Penetration Details 28
B18 Pipe Penetration Detail Penetration Details 28
B19 Timber Fascia Eaves Detail - Without Underlay Eaves Details 20
B20 Timber Fascia Eaves Detail - With Underlay Eaves Details 21
B21 Internal Fascia Gutter Detail Eaves Details 21
B22 External Fascia Gutter Detail Eaves Details 22
B23 Eaves Exposed Rafters Eaves Details 22
B24 Eaves & Rafter Detail With Sarking Eaves Details 23
B25 Spreader For Roof Discharge Apron Details 16
B26 Product Technical Data General Details 3
B27 Minimum Pitch Table General Details 3
B28 Rafter Length Table General Details 4
B29 Kickout Flashing Apron Details 16
B30 Bed & Point Finish - Flat Tile BargeDetails 13
MT01 Sarked Ceiling - Exposed Rafters General Details 4
MT02 Steep Pitched Ridge Ridge Details 6
MT03 Butt Jointed Ridge Ridge Details 7
MT04 Flexible Pointing Ridge Details 7
MT05 Barge Detail With Secret Gutter - Flat Tile Barge Details 9
MT06 Verge - Secret Gutter Barge Details 10
MT07 Verge - No Overhang Scribed Fillet Barge Details 10
MT08 Verge - No Overhang Concrete Block Barge Details 11
MT09 Flashing At Junction Of Metal Roof & Tile Barge Details 11
MT10 Mansard Detail Pitch Change Details 20
MT11 Barge Detail With Z Flashing - Flat Tile Barge Details 12
MT12 Barge Detail With Banbury Flashing - Flat Tile Barge Details 12
MT13 Stepped Cover Flashing Apron Details 17
MT14 Flashing To Brick Abutment Apron Details 17
MT15 Dutch Gable Detail Apron Details 18
MT16 Vertical Tiling Apron Details 18
MT17 Cross Section Hidden Gutter - Flat Tile Penetration Details 29
MT18 Chimney Tray Penetration Details 29
MT19 Chimney Flashing Penetration Details 30
MT20 Pipe Penetration Detail - Flat Tile Penetration Details 30
MT21 Hip Gutter Valley Details 25
MT22 Steep Pitch Roof Valley Valley Details 26
MT23 Eaves Standard Gutter Eaves Details 23
MT24 Fascia Height Eaves Details 24
MT25 Fire Wall Detail General Details 5
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
3
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay
Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -
Clay TilesType I 20° 25°Type II 20° -Type III 25° -
* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes
and shingles.
Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay
Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -
Clay TilesType I 20° 25°Type II 20° -Type III 25° -
* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes
and shingles.
Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay
Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -
Clay TilesType I 20° 25°Type II 20° -Type III 25° -
* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes
and shingles.
* Monier Hacienda profile concrete roof tiles conform to the "Type I" profile type.** Monier Horizon, Georgian, Madison profile concrete roof tiles conform to the “Type III” profile type.
GENERAL DETAILS
Horizon, Georgian,Madison Profile Roof Tile
Hacienda Profile Roof Tile
Ridge Tile
Tapered Barge Tile
Valley Tray
20mm20mm
Monier Concrete Roofing Tiles are manufactured in accordance withNZS 4206: 1992 'Concrete Interlocking Roofing Tiles'
www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245
Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2014. The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.
Technical Help0800 851 588
Product Technical Data20 January 2015
Not To Scale
b26 monier product technical data.dwg
This drawing is to be read in conjunction with Monier technical literature.
Detail: B26Issue 1
B26 PRODUCT TECHNICAL DATA
B27 MINIMUM PITCH TABLE
2020
*
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
4
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B28 RAFTER LENGTH TABLE
Maximum Rafter Lengths For Concrete Tiles Compared To Roof PitchWith Underlay Without Underlay
Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length15° 4.5M 20° 4.5M16° 5.0M 21° 5.0M17° 5.5M 22° 5.5M18° 6.0M 23° 6.0M19° 6.5M 24° 6.5M20° 7.0M 25° 7.0M21° 7.5M 26° 7.5M22° 8.0M 27° 8.0M23° 8.5M 28° 8.5M24° 9.0M 29° 9.0M25° 9.5M 30° 9.5M26° 10.0M 31° 10.0M27° 10.5M 32° 10.5M28° 11.0M 33° 11.0M29° 11.5M 34° 11.5M30° 12.0M 35° 12.0M31° 12.5M 36° 12.5M32° 13.0M 37° 13.0M33° 13.5M 38° 13.5M34° 14.0M 39° 14.0M35° 14.5M 40° 14.5M
Counter batten
Batten
Insulation
Electrical Services Duct located at bottom of Counter Batten
Rafter
Sarked Ceiling
Monier tile
Underlay
MT01 SARKED CEILING - EXPOSED RAFTERS
Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length 15° 4.5M 20° 4.5M 20° 4.5M 16° 5.0M 21° 5.0M 21° 5.0M 17° 5.5M 22° 5.5M 22° 5.5M 18° 6.0M 23° 6.0M 23° 6.0M 19° 6.5M 24° 6.5M 24° 6.5M 20° 7.0M 25° 7.0M 25° 7.0M 21° 7.5M 26° 7.5M 26° 7.5M 22° 8.0M 27° 8.0M 27° 8.0M 23° 8.5M 28° 8.5M 28° 8.5M 24° 9.0M 29° 9.0M 29° 9.0M 25° 9.5M 30° 9.5M 30° 9.5M 26° 10.0M 31° 10.0M 31° 10.0M 27° 10.5M 32° 10.5M 32° 10.5M 28° 11.0M 33° 11.0M 33° 11.0M 29° 11.5M 34° 11.5M 34° 11.5M 30° 12.0M 35° 12.0M 35° 12.0M 31° 12.5M 36° 12.5M 36° 12.5M 32° 13.0M 37° 13.0M 37° 13.0M 33° 13.5M 38° 13.5M 38° 13.5M 34° 14.0M 39° 14.0M 39° 14.0M 35° 14.5M 40° 14.5M 40° 14.5M
Maximum Rafter Lengths For Concrete Tiles Compared To Roof PitchHacienda Profile- With Underlay
Hacienda Profile- Without Underlay
Horizon, Georgian & Madison Profiles - With Underlay
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
54
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT25 FIRE WALL DETAIL
Rafter
Fire separation wall
Underlay
Tile batten
Monier tile
120mm 120mm
Mortar bedding or KAOWOOLplaced to fill space between
underside of tile and top surfaceof fire wall
Galvanised steel strap 25mm x1mm or equivalent angle fixed
between battens
B12 RIDGE DETAILRIDGE DETAILS
Monier tile
Mortar bedding
Monier Ridge Tile
Underlay where required
Mortar pointing with weepholes at the pan of eachtile
Batten
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
6
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B13 ROOF/WALL RIDGE - DETAIL CLERESTORY
Monier tile
Proprietary capping tile
Mortar pointing with weepholes at the pan of each tile
Batten
Underlay where required
Rafter
Cladding
Fixing point
Mortar bedding
Cladding cavity
70m
m
Barge board
Top of barge board 70mmabove rafter
Horizontal cavity batten
MT02 STEEP PITCHED RIDGE
Steep pitch ridge
Ridge beam & apex battens chamfered
Rafter
Tile batten
Underlay
Bedding mortar with weep holes
Monier tile
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
76
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT03 BUTT JOINTED RIDGE
Monier ridge tiles
Mortar bedding with weep holes
Underlay
Silicone joins
Monier tile
Underflashing
MT04 FLEXIBLE POINTING
Positive Pressure Chamber
Mortar bedding with weep holes
Monier ridge tileFasteners to hold tile in place
during testing
Ridge tile
Bedding material
Flexible pointing
Note:When mechanical fixing is not used - flexiblepointing is required at all times
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
8
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B05 BARGE TILE DETAILBARGE DETAILS
Monier tile
Outrigger
Batten
Fixing point
Barge board
Underlay whererequired
50m
m
Barge tile
Over roll upstand of tile underbarge tile as required *
Mortar finish
Eaves lining
* Where an over roll cannot be achieved, aZincalume® type Z flashing is to be installed.
B06 BED & POINT FINISH
Bedding mortar50mm
100x50mm Fly rafter
100mm painted fibre cementstrip installed by builder andto overhang fascia by 50mm
Monier Tile
50x50mm batten
Barge
Soffit
Cladding
Cladding cavity
Wall framing* 100mm
Zincalume® type Zflashing (Installed underthe fibre cement strip)
* Bed & Point finish requires a minimum soffitwidth of 100mm past cladding
Underlay where required.Anti-ponding boards required
for roof pitch less than 20°
15mm
100mm
50-7
0mm
Vai
able
acc
ordi
ng to
win
d zo
ne.
Ref
er to
E2/
AS
1 Ta
ble
7
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
98
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B07 SMALL PANEL METAL DETAIL
Monier tile
Batten
Fixing point
Underlay whererequired
50m
mBarge tile
Over roll upstand of tile underbarge tile as required *
Mortar finish
Eaves lining
* Where an over roll cannot be achieved, aZincalume® type Z flashing is to be installed.
Proprietary Metal Barge(Incorporated in metal
fascia/spouting system)Outrigger -100x50mm on flat
MT05 BARGE DETAIL WITH SECRET GUTTER - FLAT TILE
Monier flat tile
Batten
Fixing point
Barge board
Underlay whererequired
Eaves lining
Gable cap flashing
Abutment underflashing
30mm
Var
iabl
e ac
cord
ing
to w
ind
zone
.R
efer
to E
2/A
S1
Tabl
e 7
50-9
0mm
70m
m
Gable cap flashing manufactured to barge height
Rafter doubleto accommodateflashing and batten
130
mm
min
heig
ht
75mm
10 mm
*Note:This drawing applies to Monier Horizon,Madison and Georgian profiles
Option A:10mm notch out of every alternatebatten as a maximum spacingIntervening battens requireminimum 25mm support on rafter
Fixing point
Barge board
Eaves lining
Gable cap flashing
Rafter doubleto accommodateflashing and batten
130
mm
min
heig
ht
Outrigger
Option B:Additional support nog
Monier flat tile
Batten
Underlay whererequired
Outrigger
www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245
Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2014. The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.
Technical Help0800 851 588
Barge Detail With Secret Gutter - Monier Flat Tile Range22 December 2014
Scale 1:5
mt05 monier barge detail with secret gutter - flat tile.dwg
This drawing is to be read in conjunction with Monier technical literature.
Detail: MT05Issue 3
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
10
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT06 VERGE - SECRET GUTTER
Outrigger
Tile batten
Monier tile
Pre-primed metalsecret gutter
Pre-primed metalcapping
Barge board
Flying rafter
75mm
120m
m
MT07 VERGE - NO OVERHANG SCRIBED FILLET
Batten
Monier tiles
Rafter
Stud wall
Cladding
Building paper
Treated scribed fillet
Z Flashing
Fixing point
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
1110
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT08 VERGE - NO OVERHANG CONCRETE BLOCK
Top cord
Batten
Treated fillet to take tile fixing
Monier tile
Mortar bedding
Mortar bedding
Fixing point
Exterior plaster finish carriedunder tiles
MT09 FLASHING AT JUNCTION OF METAL ROOF & TILE
Top plate
Stud
Metal roof decking
Monier tile
Metal flashing
Acrylead / Lead flashing
Tile batten
Rafter
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
12
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT11 BARGE DETAIL WITH Z FLASHING - FLAT TILE
Monier Horizon tile
Outrigger
Batten
Fixing point
Barge board
Underlay whererequired
50m
m
Barge tile
Mortar finish
Eaves lining
10m
m 100mm
10mm
Gable flashing Gable Flashing Dimensions
Note:Use this detail when barge board is above batten
MT12 BARGE DETAIL WITH BANBURY FLASHING - FLAT TILE
Monier Horizon tile
Outrigger
Batten
Fixing point
Barge board
Underlay whererequired
50m
m
Barge tile
Mortar finish
Eaves lining
10m
m 100mm
10mm
Gable flashing Gable Flashing Dimensions
Note:Use this flashing when barge board is flush withbatten
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
1312
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B30 BED & POINT FINISH - FLAT TILE
Bedding mortar with flexiblepointing finish50mm
100x50mm Fly rafter
100mm painted fibre cementstrip installed by builder andto overhang fascia by 50mm
Monier flat tile
50x50mm batten
Barge
Soffit
Cladding
Cladding cavity
Wall framing* 100mm
Zincalume® type Zflashing (Installed underthe fibre cement strip)
* Bed & Point finish requires a minimum soffitwidth of 100mm past cladding
Underlay where required.Anti-ponding boards required
for roof pitch less than 20°
15mm
100mm
50-9
0mm
Var
iabl
e ac
cord
ing
to w
ind
zone
.R
efer
to E
2/A
S1
Tabl
e 7
*Note:This drawing applies toMonier Horizon, Madisonand Georgian profiles
Batten notched 10mm tofit flashing
www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245
Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2010 . The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.
Technical Help0800 851 588
Bed & Point Finish - Monier Flat Tile Range1 December 2014
Scale 1:5
b30 monier bed & point finish.dwg
This drawing is to be read in conjunction with Monier technical literature.
Detail: B30Issue 1
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
14
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B01 APRON DETAILS - PARALLEL FLASHING NO UNDERLAYAPRON DETAILS
Monier tile
* CladdingContinuous Support toflashingAcrylead / Lead flashing dressed
into pan, 150mm min cover
Batten
Rafter
35m
m75
mm
Square off rafter 230mmto top of nog
Minimum nog size ex100x50mm
* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.
Cladding cavity
B02 APRON DETAILS - PARALLEL FLASHING WITH UNDERLAY
Monier tile
* CladdingContinuous Support toflashingAcrylead / Lead flashing dressed
into pan, 150mm min cover
Batten
Underlay where required
Rafter
35m
m75
mm
Square off rafter 230mmto top of nog
Minimum nog size ex100x50mm
* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.
Cladding cavity
150mm min. lap
Acrylead / Lead flashing dressed with150mm min. cover over the tile
Acrylead / Lead flashing dressed with150mm min. cover over the tile
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
1514
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B03 APRON DETAILS - TRANSVERSE FLASHING WITHOUT UNDERLAY
Monier tile
* Cladding
Continuous Support toflashing
Acrylead / Lead flashing dressedinto pan, 150mm min cover
Batten
Square off rafter 230mmto top of nog
Cladding cavity
Minimum nog size ex100x50mm
230m
m
Rafter
* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.
B04 APRON DETAILS - TRANSVERSE FLASHING WITH UNDERLAY
Monier tile
* CladdingContinuous Support toflashing
Acrylead / Lead flashing dressedinto pan, 150mm min cover
Batten
Underlay where required
Square off rafter 230mmto top of nog
35m
m75
mm
Cladding cavity
Minimum nog size ex100x50mm
230m
m
Rafter
75mm min. lap
* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
16
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B25 SPREADER FOR ROOF DISCHARGE
T Junction
Downpipe
600mm min
Holes half the diameter ofthe downpipe
Notes:1. Hole positions to avoid joints in roofing.2. Hole positions to discharge into pans of tile.3. When downpipe is located in a corner, spreader is
to be "L" shaped.4. 600mm min spreader discharge pipe length.5. For rectangular (or other profile) downpipes use
the same design principle as shown.6. Underlay must be installed below spreader from
under apron to gutter line across at least 300mmfrom edge of spreader to the next truss/rafter.
7. Block ends of pipes.
B29 KICKOUT FLASHING
Fold bend behind upstand
Clout
Cladding to cover upstand by75mm minimum
Upstand 110mm behind wrapand cladding
150mm minimum cover,dressed into pan
Edge trimmed as required
Lead side flashing with taperedstop end
10mm gap required betweenwall and gutter end
50 x 50mm transition trayflashing
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
1716
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT13 STEPPED COVER FLASHING
Framing
Rafter
Top plate
Tile batten
Monier tile
Acrylead / Lead Cover flashing
Over flashing
Brick work
MT14 FLASHING TO BRICK ABUTMENT
Brick work
Acrylead / Lead flashing
Monier tile
Tile batten
Rafter
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
18
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT15 DUTCH GABLE DETAIL
Bedding and pointingFinish to verge
Weatherboard
Barge board
Hip capping
Turn up lower edge ofAcrylead / Lead flashingunder hip tile
Monier tile
Rafter
Tile batten
Monier tile
MT16 VERTICAL TILING
Building wrap
Monier tile
Tile batten
Nogging to support flashing
Acrylead / Lead flashing
Monier tile
Underlay
Rafter Timber frame
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
1918
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B08 CHANGE IN PITCH - 35 DEGREES OR LESSPITCH CHANGE DETAILS
Monier tile
Batten
Underlay whererequired
Framing
Rafters
Top roof pitch 35 ° or less
200mm min
B09 CHANGE IN PITCH - GREATER THAN 35 DEGREES
Framing
Monier tile
Batten
Underlay whererequired
Rafters
Top pitch greater than35° but less than 60°
110m
m m
in
Acrylead / Lead Flashingdressed into the pan, 150mm
cover
Fix Acrylead / Lead flashing tospecial batten ex 75x50mm
Ensure nose of tile has 10mmclearance off Acrylead / Lead
Acry
lead
/ Lea
d
Flas
hing
110m
m m
in
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
20
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT10 MANSARD DETAIL
Tile batten
Batten to support tile and flashing
Acrylead / Lead flashing
Tile
Monier tile
Rafter
B19 TIMBER FASCIA EAVES DETAIL - WITHOUT UNDERLAYEAVES DETAILS
* This fascia board measurement tobe 25mm higher than the batten
height(e.g. 50x50mm batten = 75mm
fascia height)
Fascia board
Rafter
Monier tile
50x50mm tile batten
*75mm
Note:Anti-ponding boards required for pitchesbelow 17°Refer minimum Pitch Table for tile typesand roof pitches requiring roofunderlays
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
2120
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B20 TIMBER FASCIA EAVES DETAIL - WITH UNDERLAY
250mm anti-ponding board(for low pitches see note *)
(installed by builder)Underlay where required
Fascia board
Rafter
Monier tile
Tile batten
* Note:Anti-ponding boards – to be fitted in accordance withE2/AS1,8.2.5Masonry roofs with pitches less than 17° shall haveanti-ponding boards installed. Where anti-ponding boardsare used, these shall be set to a minimum fall of 5° towardsthe fascia and shall be treated in accordance with NZS 3602.
B21 - INTERNAL FASCIA GUTTER DETAIL
Underlay where required. Anti-pondingboard where underlay used
Rafter
Monier tile
Tile batten
25mm Packer installed by builder
Underlay
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
22
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B22 EXTERNAL FASCIA GUTTER DETAIL
Underlay where required (see note *).Anti-ponding board required where underlay used
Rafter
Monier tile
Tile batten
25mm Packer installed by builderwhere required
Underlay
* Note: Refer minimum Pitch Table fortile types and roof pitches requiring roofunderlays.
B23 EAVES EXPOSED RAFTERS
250mm anti-ponding board(See Note *)
Underlay where required(See Note *)
Fascia purlin(Fascia purlin & eaves lining,
where installed, on top of truss tobe 25mm higher than tile batten)
Rafter
Monier tile
50x50mm tile batten
Cavity
Exterior cladding
Rafter
Eaves lining notched into raftersor resting on top of truss
* Note:Anti-ponding boards – to be fitted in accordance withE2/AS1,8.2.5Masonry roofs with pitches less than 17° shall haveanti-ponding boards installed. Where anti-pondingboards are used, these shall be set to a minimum fallof 5° towards the fascia and shall be treated inaccordance with NZS 3602.
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
2322
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B24 EAVES & RAFTER DETAIL WITH SARKING
250mm anti-ponding boardSee Note *
Underlay mandatory oversloping ceilings
Fascia board
Ceiling Lining
Rafter
Monier tile
50x50mm tile batten
*75mm
*75mm to top of anti-ponding board off top of counter batten.
* Note:Anti-ponding boards – to be fitted in accordancewith E2/AS1,8.2.5.Masonry roofs with pitches less than 17° shallhave anti-ponding boards installed. Whereanti-ponding boards are used, these shall beset to a minimum fall of 5° towards the fasciaand shall be treated in accordance with NZS3602.
MT23 EAVES STANDARD GUTTER
Monier tile
Underlay
Anti-ponding board
Standard gutter
Fascia
Eaves lining
Nogging
50 - 55mm
overhang
75mm
Rafter
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
24
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT24 FASCIA HEIGHT
Rafter
Tile batten50 x 50 softwood
Fascia height 25mm
Gutter
B10 VALLEY DETAIL WITHOUT UNDERLAYVALLEY DETAILS
Valley boards 25x150mm
50m
m m
in 100mm
20m
m
Valley tray
Splay batten 50x50mm
50mm min
250mm min. gutter width
Monier tile100mm cover over valley
tray
Underlay between valley tray & valley boardis mandatory (for separation) If metal valleytray is used with CCA treated valley boards.
100mm
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
2524
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B11 VALLEY DETAIL WITH UNDERLAY
Valley boards 25x150mm50
mm
min
100mm
20m
m
Valley tray
Splay batten 50x50mm
50mm min
250mm min. gutter width
Monier tile100mm cover over
valley tray
Underlay between valley tray and valleyboard is mandatory (for separation) If metalvalley tray is used with CCA treated valley
boards.
100mm
Underlay where required
MT21 HIP GUTTER
Nogging
Expanded mesh
Valley run-off at hip
Valley boards
Rafter
Monier tile
Mortar bedding
Fibre cement strip
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
26
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT22 STEEP PITCH ROOF VALLEY
Top chord
Tile batten
Valley tray on boardsand underlay
Water diversion ribValley battenTop chord
Tile batten
B14 PLAN VIEW OF THREE SIDED PENETRATIONPENETRATION DETAILS
Edge battens
Roof line edge
Roof line edge
Gutter Framing
Gutter
Cladding
Framed penetration(e.g. chimney)
A ASee cross section
detail b17
Also see details:b15 monier abutment detail for framed penetration.dwgb16 monier elevation-section view of three sided penetration.dwgb17 monier cross section of hidden gutter.dwg for details
See cross section detail b15
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
2726
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B15 ABUTMENT DETAIL FOR FRAMED PENETRATION
Cladding lap over upstandCladding
Nog for upstand
Bottom of gutter to dischargeinto side hidden gutter (then into
spouting) see detail b17
Gutter board at abutmenton nogs to suit
75m
m M
in L
ap
Cladding cavity
Butyl, EPDM lining carried overanti-ponding board and up
abutment frame on nog to suit.Dress around sides of
penetration at ends
250mm anti-ponding board laidto fall - See note *
Underlay
Monier tile
Tile batten
100mm min
50m
m m
in D
eep
* Note:Anti-ponding boards – to be fitted in accordance with E2/AS1,8.2.5Masonry roofs with pitches less than 17° shall have anti-ponding boards installed. Where anti-ponding boards are used, these shallbe set to a minimum fall of 5° towards the fascia and shall be treated in accordance with NZS 3602.
To designer's specification butcladding must finish 50mmminimum above gutter lining
Also see details:b14 monier plan view of three sided penetration.dwgb16 monier elevation-section view of three sided penetration.dwgb17 monier cross section of hidden gutter.dwg for details
Cross Section BB(from B14 Monier Plan View Of Three Sided Penetration)
B16 ELEVATION/SECTION VIEW OF THREE SIDED PENETRATION
Fascia board
Rafter
Monier tile
Chimney
Hidden gutter discharginginto gutter
Gutter
See detail mt15 for further information
Also see details:b14 monier plan view of three sided penetration.dwgb15 monier abutment detail for framed penetration.dwgb17 monier cross section of hidden gutter.dwg for details
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
28
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
B17 CROSS SECTION OF HIDDEN GUTTER
Monier tile
Cladding
Tile Batten
Underlay where required
Rafter
100m
m200m
m m
in.
Support Nog
Cladding cavity
Edge Batten
Cross Section A-A(from b14 Monier Plan View Of Three Sided Penetration)
E2/AS1 Approvedmembrane on substrate
Also see details:b14 monier plan view of three sided penetration.dwgb15 monier abutment detail for framed penetration.dwgb16 monier elevation-section view of three sided penetration.dwg for details
100mm min
B18 PIPE PENETRATION DETAIL
Stack/vent pipe withventing cap carried
through tile
Acrylead / Lead carried to topedge of the tile under the
overlap
Monier Concrete Tiles
Dress Acrylead / Lead sleeve100mm up pipe and solder toAcrylead / Lead flashing over tileCollar sealed to pipe over
Acrylead / Lead flashing
Acrylead / Lead flashing dressedto roof tile min 150mm all round
and carried up to edge of tile
Acrylead / Lead dressed downover bottom edge of tile or150mm, whichever is less
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
2928
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT17 CROSS SECTION HIDDEN GUTTER - FLAT TILE
MonierHorizon tile
Cladding
Tile Batten
Underlay whererequired
Rafter - double toaccommodate flashingand batten
100m
m
200m
m m
in.
Support Nog
Cladding cavity
Edge Batten
Abutment underflashing
50m
m
50mm
50m
m
50m
m 200m
m
Abutment flashingdimensions
Abutment flashingextension to continuethrough to centre line
Building wrap
Acrylead / Lead
MT18 CHIMNEY TRAY
Weep hole
Over flashing
Back gutter
Monier tile
Boarding block tosupport back gutter
Tile batten
Rafter
Stop flashing
Chimney tray
Chimney tray
AR
CH
ITE
CTU
RA
L D
RA
WIN
GS
30
NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.
MT19 CHIMNEY FLASHING
Over flashing
Back gutter
Monier tile
Boarding block tosupport back gutter
Tile batten
Rafter
Stop flashing
MT20 PIPE PENETRATION DETAIL - FLAT TILE
Stack/vent pipe withventing cap carried
through tile
Acrylead / Lead carried to top edgeof the tile under the overlap
(upper tiles lifted to illustrate)
Monier tiles
Dress Acrylead / Lead sleeve100mm up pipe and solder tolead flashing over tile
Collar sealed to pipe overAcrylead / Lead flashing
Acrylead / Lead flashing dressed toroof tile min 150mm all round and
carried up to edge of tileAcrylead / Lead dressed downover bottom edge of tile or150mm, whichever is less
Apply silicon to completeperimeter of opening before fittingAcrylead / Lead flashing