ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier...

32
ARCHITECTURAL DRAWINGS

Transcript of ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier...

Page 1: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

ARCHITECTURAL DRAWINGS

Page 2: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

USE OF ARCHITECTURAL DRAWINGS INDEX OF DRAWINGS BY DETAIL NUMBER GENERAL DETAILS

B26 Product Technical Data 3B27 Minimum Pitch Table 3B28 Rafter Length Table 4MT01 Sarked Ceiling - Exposed Rafters 4MT25 Fire Wall Detail 5

RIDGE DETAILS B12 Ridge Detail 5B13 Roof/Wall Ridge - Detail/Clerestorey 6MT02 Steep Pitched Ridge 6MT03 Butt Jointed Ridge 7 MT04 Flexible Pointing 7

BARGE DETAILS B05 Barge Tile Detail 8B06 Bed & Point Finish 8B07 Small Panel Metal Detail 9MT05 Barge Detail With Secret Gutter - Flat Tile 9MT06 Verge - Secret Gutter 10MT07 Verge - No Overhang Scribed Fillet 10MT08 Verge - No Overhang Concrete Block 11MT09 Flashing At Junction Of Metal Roof & Tile 11MT11 Barge Detail With Z Flashing - Flat Tile 12MT12 Barge Detail With Banbury Flashing - Flat Tile 12B30 Bed & Point Finish - Flat Tile 13

APRON DETAILS B01 Apron Details - Parallel Flashing Without Underlay 14B02 Apron Details - Parallel Flashing With Underlay 14B03 Apron Details - Transverse Flashing Without Underlay 15B04 Apron Details - Transverse Flashing With Underlay 15B25 Spreader For Roof Discharge 16B29 Kickout Flashing 16MT13 Stepped Cover Flashing 17MT14 Flashing To Brick Abutment 17MT15 Dutch Gable Detail 18MT16 Vertical Tiling 18

PITCH CHANGE DETAILS B08 Change In Pitch -35 Degrees Or Less 19B09 Change In Pitch - Greater Than 35 Degrees 19MT10 Mansard Detail 20

EAVES DETAILS B19 Timber Fascia Eaves Detail - Without Underlay 20B20 Timber Fascia Eaves Detail - With Underlay 21B21 Internal Fascia Gutter Detail 21B22 External Fascia Gutter Detail 22B23 Eaves Exposed Rafters 22B24 Eaves & Rafter Detail With Sarking 23MT23 Eaves Standard Gutter 23MT24 Fascia Height 24

VALLEY DETAILS B10 Valley Detail Without Underlay 24B11 Valley Detail With Underlay 25MT21 Hip Gutter 25MT22 Steep Pitch Roof Valley 26

PENETRATION DETAILS B14 Plan View Of Three Sided Penetration 26B15 Abutment Detail For Framed Penetration 27B16 Elevation/Section View Of Three Sided Penetration 27B17 Cross Section Of Hidden Gutter 28B18 Pipe Penetration Detail 28MT17 Cross Section Hidden Gutter - Flat Tile 29MT18 Chimney Tray 29MT19 Chimney Flashing 30MT20 Pipe Penetration Detail - Flat Tile 30

CONTENTS

Page 3: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

1

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

USE OF ARCHITECTURAL DRAWINGSMonier roofing systems provide contemporary and innovative design solutions that benefit from the time proven effectiveness and sustainability of tiles. This manual contains a broad range of roofing details and applications enabling architects and specifiers to easily access and assess the suitability of design for their client.

MONIER DETAIL DRAWINGS NOW ONLINE

Monier roofing detail drawings are available in multiple CAD formats and as enlarged PDF files at monier.co.nz.

The information provided in the drawings provide reference information on the typical use of the Monier product. The information provided in this reference guide is generic innature; it does not contain the full details required for construction, nor does it constitute an express statement as to fitness for a particular purpose. Professional advice is required to take into account all site and design specific influences. Designers and specifiers will typically provide details specific to particular projects: these should always be referred to in preference to the default systemof drawings. The instructions and detailsavailable refer to both concrete and terracotta tiles (except where specifically noted).

MONIER COMPLIANCE WITH THENEW ZEALAND BUILDING CODE

When installed according to the manufacturers instructions, Monier products will meet theDurability performance requirements of NZBC B2 and E2.Methods used for verifying compliance with the relevant performances of the New ZealandBuilding Code, include testing and assessment by a laboratory, ease of installation assessment, assessment of data provided bythe manufacturer and the inservice history overseas and in New Zealand. Details areavailable from Monier.

IMPORTANT INFORMATION FORSPECIFICATION, PREPARATION& INSTALLATION

This manual has been prepared by Monier to assists the architect, builder and installer to specify, prepare and install roof tiles.While it is not possible to detail every condition that may be encountered, Monier will assist to advise on any special situationsthat may occur.This manual has been written as a working guide for industry, however it is not intended to replace good trade practice and experience essential to obtaining a quality roof installation. Nor does this manual overridespecific advice received from Monier fixing services.Architects and specifiers should ensure that the details provided in this manual are followed and determined to their ownsatisfaction that the job is complete to an acceptable standard of trade practice. Allcare has been taken in the compilation of this manual. However, Monier accepts noresponsibility or liability for the contents of the manual (including any printing or typographical errors) and recommends that all standards and recommendations are independently checked.

SPECIFICATIONS

While information contained in this manual is correct at the time of creation, specifications are subject to change without notice.

DISCLAIMER

This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specificapplication. Nothing in this information constitutes a statement of fitness for particularpurpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products.© 2010 The copyright of this document is the property of CSR Building Products (NZ) Ltd trading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.

Page 4: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

MO

NIE

R A

RC

HIT

EC

TU

RA

L D

RA

WIN

GS

SE

CTI

ON

8

2

INDEX OF DRAWINGS BY DETAIL NUMBERDetail Category PageB01 Apron Details - Parallel Flashing Without Underlay Apron Details 14

B02 Apron Details - Parallel Flashing With Underlay Apron Details 14

B03 Apron Details - Transverse Flashing Without Underlay Apron Details 15

B04 Apron Details - Transverse Flashing With Underlay Apron Details 15

B05 Barge Tile Detail Barge Details 8

B06 Bed & Point Finish Barge Details 8

B07 Small Panel Metal Detail Barge Details 9

B08 Change In Pitch - 35 degrees Or Less Pitch Change Details 19

B09 Change In Pitch - Greater Than 35 Degrees Pitch Change Details 19

B10 Valley Detail Without Underlay Valley Details 24

B11 Valley Detail With Underlay Valley Details 25

B12 Ridge Detail Ridge Details 5

B13 Roof/Wall Ridge - Detail/Clerestorey Ridge Details 6

B14 Plan View Of Three Sided Penetration Penetration Details 26

B15 Abutment Detail For Framed Penetration Penetration Details 27

B16 Elevation/Section View Of Three Sided Penetration Penetration Details 27

B17 Cross Section Of Hidden Gutter Penetration Details 28

B18 Pipe Penetration Detail Penetration Details 28

B19 Timber Fascia Eaves Detail - Without Underlay Eaves Details 20

B20 Timber Fascia Eaves Detail - With Underlay Eaves Details 21

B21 Internal Fascia Gutter Detail Eaves Details 21

B22 External Fascia Gutter Detail Eaves Details 22

B23 Eaves Exposed Rafters Eaves Details 22

B24 Eaves & Rafter Detail With Sarking Eaves Details 23

B25 Spreader For Roof Discharge Apron Details 16

B26 Product Technical Data General Details 3

B27 Minimum Pitch Table General Details 3

B28 Rafter Length Table General Details 4

B29 Kickout Flashing Apron Details 16

B30 Bed & Point Finish - Flat Tile BargeDetails 13

MT01 Sarked Ceiling - Exposed Rafters General Details 4

MT02 Steep Pitched Ridge Ridge Details 6

MT03 Butt Jointed Ridge Ridge Details 7

MT04 Flexible Pointing Ridge Details 7

MT05 Barge Detail With Secret Gutter - Flat Tile Barge Details 9

MT06 Verge - Secret Gutter Barge Details 10

MT07 Verge - No Overhang Scribed Fillet Barge Details 10

MT08 Verge - No Overhang Concrete Block Barge Details 11

MT09 Flashing At Junction Of Metal Roof & Tile Barge Details 11

MT10 Mansard Detail Pitch Change Details 20

MT11 Barge Detail With Z Flashing - Flat Tile Barge Details 12

MT12 Barge Detail With Banbury Flashing - Flat Tile Barge Details 12

MT13 Stepped Cover Flashing Apron Details 17

MT14 Flashing To Brick Abutment Apron Details 17

MT15 Dutch Gable Detail Apron Details 18

MT16 Vertical Tiling Apron Details 18

MT17 Cross Section Hidden Gutter - Flat Tile Penetration Details 29

MT18 Chimney Tray Penetration Details 29

MT19 Chimney Flashing Penetration Details 30

MT20 Pipe Penetration Detail - Flat Tile Penetration Details 30

MT21 Hip Gutter Valley Details 25

MT22 Steep Pitch Roof Valley Valley Details 26

MT23 Eaves Standard Gutter Eaves Details 23

MT24 Fascia Height Eaves Details 24

MT25 Fire Wall Detail General Details 5

Page 5: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

3

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay

Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -

Clay TilesType I 20° 25°Type II 20° -Type III 25° -

* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes

and shingles.

Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay

Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -

Clay TilesType I 20° 25°Type II 20° -Type III 25° -

* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes

and shingles.

Minimum Pitches for Concrete & Clay TilesTile Material Profile Type With Underlay (Refer Note Without Underlay

Concrete TilesType I* 15° 20°Type II 20° -Type III 25° -

Clay TilesType I 20° 25°Type II 20° -Type III 25° -

* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile type.Type I Type 1: Double tiles having two distinct watercourses with a minimum watercourse depth of 18mm.Type II Single profile tiles having one watercourse a minimum of 25mm in heightType III Tiles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakes

and shingles.

* Monier Hacienda profile concrete roof tiles conform to the "Type I" profile type.** Monier Horizon, Georgian, Madison profile concrete roof tiles conform to the “Type III” profile type.

GENERAL DETAILS

Horizon, Georgian,Madison Profile Roof Tile

Hacienda Profile Roof Tile

Ridge Tile

Tapered Barge Tile

Valley Tray

20mm20mm

Monier Concrete Roofing Tiles are manufactured in accordance withNZS 4206: 1992 'Concrete Interlocking Roofing Tiles'

www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245

[email protected]

Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2014. The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.

Technical Help0800 851 588

Product Technical Data20 January 2015

Not To Scale

b26 monier product technical data.dwg

This drawing is to be read in conjunction with Monier technical literature.

Detail: B26Issue 1

B26 PRODUCT TECHNICAL DATA

B27 MINIMUM PITCH TABLE

2020

*

Page 6: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

4

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B28 RAFTER LENGTH TABLE

Maximum Rafter Lengths For Concrete Tiles Compared To Roof PitchWith Underlay Without Underlay

Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length15° 4.5M 20° 4.5M16° 5.0M 21° 5.0M17° 5.5M 22° 5.5M18° 6.0M 23° 6.0M19° 6.5M 24° 6.5M20° 7.0M 25° 7.0M21° 7.5M 26° 7.5M22° 8.0M 27° 8.0M23° 8.5M 28° 8.5M24° 9.0M 29° 9.0M25° 9.5M 30° 9.5M26° 10.0M 31° 10.0M27° 10.5M 32° 10.5M28° 11.0M 33° 11.0M29° 11.5M 34° 11.5M30° 12.0M 35° 12.0M31° 12.5M 36° 12.5M32° 13.0M 37° 13.0M33° 13.5M 38° 13.5M34° 14.0M 39° 14.0M35° 14.5M 40° 14.5M

Counter batten

Batten

Insulation

Electrical Services Duct located at bottom of Counter Batten

Rafter

Sarked Ceiling

Monier tile

Underlay

MT01 SARKED CEILING - EXPOSED RAFTERS

Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length Roof Pitch Max. Rafter Length 15° 4.5M 20° 4.5M 20° 4.5M 16° 5.0M 21° 5.0M 21° 5.0M 17° 5.5M 22° 5.5M 22° 5.5M 18° 6.0M 23° 6.0M 23° 6.0M 19° 6.5M 24° 6.5M 24° 6.5M 20° 7.0M 25° 7.0M 25° 7.0M 21° 7.5M 26° 7.5M 26° 7.5M 22° 8.0M 27° 8.0M 27° 8.0M 23° 8.5M 28° 8.5M 28° 8.5M 24° 9.0M 29° 9.0M 29° 9.0M 25° 9.5M 30° 9.5M 30° 9.5M 26° 10.0M 31° 10.0M 31° 10.0M 27° 10.5M 32° 10.5M 32° 10.5M 28° 11.0M 33° 11.0M 33° 11.0M 29° 11.5M 34° 11.5M 34° 11.5M 30° 12.0M 35° 12.0M 35° 12.0M 31° 12.5M 36° 12.5M 36° 12.5M 32° 13.0M 37° 13.0M 37° 13.0M 33° 13.5M 38° 13.5M 38° 13.5M 34° 14.0M 39° 14.0M 39° 14.0M 35° 14.5M 40° 14.5M 40° 14.5M

Maximum Rafter Lengths For Concrete Tiles Compared To Roof PitchHacienda Profile- With Underlay

Hacienda Profile- Without Underlay

Horizon, Georgian & Madison Profiles - With Underlay

Page 7: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

54

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT25 FIRE WALL DETAIL

Rafter

Fire separation wall

Underlay

Tile batten

Monier tile

120mm 120mm

Mortar bedding or KAOWOOLplaced to fill space between

underside of tile and top surfaceof fire wall

Galvanised steel strap 25mm x1mm or equivalent angle fixed

between battens

B12 RIDGE DETAILRIDGE DETAILS

Monier tile

Mortar bedding

Monier Ridge Tile

Underlay where required

Mortar pointing with weepholes at the pan of eachtile

Batten

Page 8: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

6

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B13 ROOF/WALL RIDGE - DETAIL CLERESTORY

Monier tile

Proprietary capping tile

Mortar pointing with weepholes at the pan of each tile

Batten

Underlay where required

Rafter

Cladding

Fixing point

Mortar bedding

Cladding cavity

70m

m

Barge board

Top of barge board 70mmabove rafter

Horizontal cavity batten

MT02 STEEP PITCHED RIDGE

Steep pitch ridge

Ridge beam & apex battens chamfered

Rafter

Tile batten

Underlay

Bedding mortar with weep holes

Monier tile

Page 9: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

76

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT03 BUTT JOINTED RIDGE

Monier ridge tiles

Mortar bedding with weep holes

Underlay

Silicone joins

Monier tile

Underflashing

MT04 FLEXIBLE POINTING

Positive Pressure Chamber

Mortar bedding with weep holes

Monier ridge tileFasteners to hold tile in place

during testing

Ridge tile

Bedding material

Flexible pointing

Note:When mechanical fixing is not used - flexiblepointing is required at all times

Page 10: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

8

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B05 BARGE TILE DETAILBARGE DETAILS

Monier tile

Outrigger

Batten

Fixing point

Barge board

Underlay whererequired

50m

m

Barge tile

Over roll upstand of tile underbarge tile as required *

Mortar finish

Eaves lining

* Where an over roll cannot be achieved, aZincalume® type Z flashing is to be installed.

B06 BED & POINT FINISH

Bedding mortar50mm

100x50mm Fly rafter

100mm painted fibre cementstrip installed by builder andto overhang fascia by 50mm

Monier Tile

50x50mm batten

Barge

Soffit

Cladding

Cladding cavity

Wall framing* 100mm

Zincalume® type Zflashing (Installed underthe fibre cement strip)

* Bed & Point finish requires a minimum soffitwidth of 100mm past cladding

Underlay where required.Anti-ponding boards required

for roof pitch less than 20°

15mm

100mm

50-7

0mm

Vai

able

acc

ordi

ng to

win

d zo

ne.

Ref

er to

E2/

AS

1 Ta

ble

7

Page 11: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

98

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B07 SMALL PANEL METAL DETAIL

Monier tile

Batten

Fixing point

Underlay whererequired

50m

mBarge tile

Over roll upstand of tile underbarge tile as required *

Mortar finish

Eaves lining

* Where an over roll cannot be achieved, aZincalume® type Z flashing is to be installed.

Proprietary Metal Barge(Incorporated in metal

fascia/spouting system)Outrigger -100x50mm on flat

MT05 BARGE DETAIL WITH SECRET GUTTER - FLAT TILE

Monier flat tile

Batten

Fixing point

Barge board

Underlay whererequired

Eaves lining

Gable cap flashing

Abutment underflashing

30mm

Var

iabl

e ac

cord

ing

to w

ind

zone

.R

efer

to E

2/A

S1

Tabl

e 7

50-9

0mm

70m

m

Gable cap flashing manufactured to barge height

Rafter doubleto accommodateflashing and batten

130

mm

min

heig

ht

75mm

10 mm

*Note:This drawing applies to Monier Horizon,Madison and Georgian profiles

Option A:10mm notch out of every alternatebatten as a maximum spacingIntervening battens requireminimum 25mm support on rafter

Fixing point

Barge board

Eaves lining

Gable cap flashing

Rafter doubleto accommodateflashing and batten

130

mm

min

heig

ht

Outrigger

Option B:Additional support nog

Monier flat tile

Batten

Underlay whererequired

Outrigger

www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245

[email protected]

Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2014. The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.

Technical Help0800 851 588

Barge Detail With Secret Gutter - Monier Flat Tile Range22 December 2014

Scale 1:5

mt05 monier barge detail with secret gutter - flat tile.dwg

This drawing is to be read in conjunction with Monier technical literature.

Detail: MT05Issue 3

Page 12: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

10

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT06 VERGE - SECRET GUTTER

Outrigger

Tile batten

Monier tile

Pre-primed metalsecret gutter

Pre-primed metalcapping

Barge board

Flying rafter

75mm

120m

m

MT07 VERGE - NO OVERHANG SCRIBED FILLET

Batten

Monier tiles

Rafter

Stud wall

Cladding

Building paper

Treated scribed fillet

Z Flashing

Fixing point

Page 13: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

1110

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT08 VERGE - NO OVERHANG CONCRETE BLOCK

Top cord

Batten

Treated fillet to take tile fixing

Monier tile

Mortar bedding

Mortar bedding

Fixing point

Exterior plaster finish carriedunder tiles

MT09 FLASHING AT JUNCTION OF METAL ROOF & TILE

Top plate

Stud

Metal roof decking

Monier tile

Metal flashing

Acrylead / Lead flashing

Tile batten

Rafter

Page 14: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

12

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT11 BARGE DETAIL WITH Z FLASHING - FLAT TILE

Monier Horizon tile

Outrigger

Batten

Fixing point

Barge board

Underlay whererequired

50m

m

Barge tile

Mortar finish

Eaves lining

10m

m 100mm

10mm

Gable flashing Gable Flashing Dimensions

Note:Use this detail when barge board is above batten

MT12 BARGE DETAIL WITH BANBURY FLASHING - FLAT TILE

Monier Horizon tile

Outrigger

Batten

Fixing point

Barge board

Underlay whererequired

50m

m

Barge tile

Mortar finish

Eaves lining

10m

m 100mm

10mm

Gable flashing Gable Flashing Dimensions

Note:Use this flashing when barge board is flush withbatten

Page 15: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

1312

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B30 BED & POINT FINISH - FLAT TILE

Bedding mortar with flexiblepointing finish50mm

100x50mm Fly rafter

100mm painted fibre cementstrip installed by builder andto overhang fascia by 50mm

Monier flat tile

50x50mm batten

Barge

Soffit

Cladding

Cladding cavity

Wall framing* 100mm

Zincalume® type Zflashing (Installed underthe fibre cement strip)

* Bed & Point finish requires a minimum soffitwidth of 100mm past cladding

Underlay where required.Anti-ponding boards required

for roof pitch less than 20°

15mm

100mm

50-9

0mm

Var

iabl

e ac

cord

ing

to w

ind

zone

.R

efer

to E

2/A

S1

Tabl

e 7

*Note:This drawing applies toMonier Horizon, Madisonand Georgian profiles

Batten notched 10mm tofit flashing

www.monier.co.nzMonier TileMonier RoofingPO Box 188,Takanini,Auckland 2245

[email protected]

Disclaimer: This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non-Monier products. © 2010 . The copyright of this document is the property of CSR Building Products (NZ) Ltdtrading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly, nor used for any purpose other than that for which it is specifically furnished without prior consent.

Technical Help0800 851 588

Bed & Point Finish - Monier Flat Tile Range1 December 2014

Scale 1:5

b30 monier bed & point finish.dwg

This drawing is to be read in conjunction with Monier technical literature.

Detail: B30Issue 1

Page 16: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

14

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B01 APRON DETAILS - PARALLEL FLASHING NO UNDERLAYAPRON DETAILS

Monier tile

* CladdingContinuous Support toflashingAcrylead / Lead flashing dressed

into pan, 150mm min cover

Batten

Rafter

35m

m75

mm

Square off rafter 230mmto top of nog

Minimum nog size ex100x50mm

* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.

Cladding cavity

B02 APRON DETAILS - PARALLEL FLASHING WITH UNDERLAY

Monier tile

* CladdingContinuous Support toflashingAcrylead / Lead flashing dressed

into pan, 150mm min cover

Batten

Underlay where required

Rafter

35m

m75

mm

Square off rafter 230mmto top of nog

Minimum nog size ex100x50mm

* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.

Cladding cavity

150mm min. lap

Acrylead / Lead flashing dressed with150mm min. cover over the tile

Acrylead / Lead flashing dressed with150mm min. cover over the tile

Page 17: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

1514

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B03 APRON DETAILS - TRANSVERSE FLASHING WITHOUT UNDERLAY

Monier tile

* Cladding

Continuous Support toflashing

Acrylead / Lead flashing dressedinto pan, 150mm min cover

Batten

Square off rafter 230mmto top of nog

Cladding cavity

Minimum nog size ex100x50mm

230m

m

Rafter

* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.

B04 APRON DETAILS - TRANSVERSE FLASHING WITH UNDERLAY

Monier tile

* CladdingContinuous Support toflashing

Acrylead / Lead flashing dressedinto pan, 150mm min cover

Batten

Underlay where required

Square off rafter 230mmto top of nog

35m

m75

mm

Cladding cavity

Minimum nog size ex100x50mm

230m

m

Rafter

75mm min. lap

* Where cladding manufacturer requires more than75mm of apron upstand under cladding, claddingsupplier to supply and install over flashing to suittheir requirements.For details refer to cladding manufacturer.

Page 18: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

16

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B25 SPREADER FOR ROOF DISCHARGE

T Junction

Downpipe

600mm min

Holes half the diameter ofthe downpipe

Notes:1. Hole positions to avoid joints in roofing.2. Hole positions to discharge into pans of tile.3. When downpipe is located in a corner, spreader is

to be "L" shaped.4. 600mm min spreader discharge pipe length.5. For rectangular (or other profile) downpipes use

the same design principle as shown.6. Underlay must be installed below spreader from

under apron to gutter line across at least 300mmfrom edge of spreader to the next truss/rafter.

7. Block ends of pipes.

B29 KICKOUT FLASHING

Fold bend behind upstand

Clout

Cladding to cover upstand by75mm minimum

Upstand 110mm behind wrapand cladding

150mm minimum cover,dressed into pan

Edge trimmed as required

Lead side flashing with taperedstop end

10mm gap required betweenwall and gutter end

50 x 50mm transition trayflashing

Page 19: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

1716

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT13 STEPPED COVER FLASHING

Framing

Rafter

Top plate

Tile batten

Monier tile

Acrylead / Lead Cover flashing

Over flashing

Brick work

MT14 FLASHING TO BRICK ABUTMENT

Brick work

Acrylead / Lead flashing

Monier tile

Tile batten

Rafter

Page 20: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

18

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT15 DUTCH GABLE DETAIL

Bedding and pointingFinish to verge

Weatherboard

Barge board

Hip capping

Turn up lower edge ofAcrylead / Lead flashingunder hip tile

Monier tile

Rafter

Tile batten

Monier tile

MT16 VERTICAL TILING

Building wrap

Monier tile

Tile batten

Nogging to support flashing

Acrylead / Lead flashing

Monier tile

Underlay

Rafter Timber frame

Page 21: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

1918

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B08 CHANGE IN PITCH - 35 DEGREES OR LESSPITCH CHANGE DETAILS

Monier tile

Batten

Underlay whererequired

Framing

Rafters

Top roof pitch 35 ° or less

200mm min

B09 CHANGE IN PITCH - GREATER THAN 35 DEGREES

Framing

Monier tile

Batten

Underlay whererequired

Rafters

Top pitch greater than35° but less than 60°

110m

m m

in

Acrylead / Lead Flashingdressed into the pan, 150mm

cover

Fix Acrylead / Lead flashing tospecial batten ex 75x50mm

Ensure nose of tile has 10mmclearance off Acrylead / Lead

Acry

lead

/ Lea

d

Flas

hing

110m

m m

in

Page 22: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

20

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT10 MANSARD DETAIL

Tile batten

Batten to support tile and flashing

Acrylead / Lead flashing

Tile

Monier tile

Rafter

B19 TIMBER FASCIA EAVES DETAIL - WITHOUT UNDERLAYEAVES DETAILS

* This fascia board measurement tobe 25mm higher than the batten

height(e.g. 50x50mm batten = 75mm

fascia height)

Fascia board

Rafter

Monier tile

50x50mm tile batten

*75mm

Note:Anti-ponding boards required for pitchesbelow 17°Refer minimum Pitch Table for tile typesand roof pitches requiring roofunderlays

Page 23: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

2120

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B20 TIMBER FASCIA EAVES DETAIL - WITH UNDERLAY

250mm anti-ponding board(for low pitches see note *)

(installed by builder)Underlay where required

Fascia board

Rafter

Monier tile

Tile batten

* Note:Anti-ponding boards – to be fitted in accordance withE2/AS1,8.2.5Masonry roofs with pitches less than 17° shall haveanti-ponding boards installed. Where anti-ponding boardsare used, these shall be set to a minimum fall of 5° towardsthe fascia and shall be treated in accordance with NZS 3602.

B21 - INTERNAL FASCIA GUTTER DETAIL

Underlay where required. Anti-pondingboard where underlay used

Rafter

Monier tile

Tile batten

25mm Packer installed by builder

Underlay

Page 24: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

22

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B22 EXTERNAL FASCIA GUTTER DETAIL

Underlay where required (see note *).Anti-ponding board required where underlay used

Rafter

Monier tile

Tile batten

25mm Packer installed by builderwhere required

Underlay

* Note: Refer minimum Pitch Table fortile types and roof pitches requiring roofunderlays.

B23 EAVES EXPOSED RAFTERS

250mm anti-ponding board(See Note *)

Underlay where required(See Note *)

Fascia purlin(Fascia purlin & eaves lining,

where installed, on top of truss tobe 25mm higher than tile batten)

Rafter

Monier tile

50x50mm tile batten

Cavity

Exterior cladding

Rafter

Eaves lining notched into raftersor resting on top of truss

* Note:Anti-ponding boards – to be fitted in accordance withE2/AS1,8.2.5Masonry roofs with pitches less than 17° shall haveanti-ponding boards installed. Where anti-pondingboards are used, these shall be set to a minimum fallof 5° towards the fascia and shall be treated inaccordance with NZS 3602.

Page 25: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

2322

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B24 EAVES & RAFTER DETAIL WITH SARKING

250mm anti-ponding boardSee Note *

Underlay mandatory oversloping ceilings

Fascia board

Ceiling Lining

Rafter

Monier tile

50x50mm tile batten

*75mm

*75mm to top of anti-ponding board off top of counter batten.

* Note:Anti-ponding boards – to be fitted in accordancewith E2/AS1,8.2.5.Masonry roofs with pitches less than 17° shallhave anti-ponding boards installed. Whereanti-ponding boards are used, these shall beset to a minimum fall of 5° towards the fasciaand shall be treated in accordance with NZS3602.

MT23 EAVES STANDARD GUTTER

Monier tile

Underlay

Anti-ponding board

Standard gutter

Fascia

Eaves lining

Nogging

50 - 55mm

overhang

75mm

Rafter

Page 26: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

24

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT24 FASCIA HEIGHT

Rafter

Tile batten50 x 50 softwood

Fascia height 25mm

Gutter

B10 VALLEY DETAIL WITHOUT UNDERLAYVALLEY DETAILS

Valley boards 25x150mm

50m

m m

in 100mm

20m

m

Valley tray

Splay batten 50x50mm

50mm min

250mm min. gutter width

Monier tile100mm cover over valley

tray

Underlay between valley tray & valley boardis mandatory (for separation) If metal valleytray is used with CCA treated valley boards.

100mm

Page 27: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

2524

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B11 VALLEY DETAIL WITH UNDERLAY

Valley boards 25x150mm50

mm

min

100mm

20m

m

Valley tray

Splay batten 50x50mm

50mm min

250mm min. gutter width

Monier tile100mm cover over

valley tray

Underlay between valley tray and valleyboard is mandatory (for separation) If metalvalley tray is used with CCA treated valley

boards.

100mm

Underlay where required

MT21 HIP GUTTER

Nogging

Expanded mesh

Valley run-off at hip

Valley boards

Rafter

Monier tile

Mortar bedding

Fibre cement strip

Page 28: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

26

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT22 STEEP PITCH ROOF VALLEY

Top chord

Tile batten

Valley tray on boardsand underlay

Water diversion ribValley battenTop chord

Tile batten

B14 PLAN VIEW OF THREE SIDED PENETRATIONPENETRATION DETAILS

Edge battens

Roof line edge

Roof line edge

Gutter Framing

Gutter

Cladding

Framed penetration(e.g. chimney)

A ASee cross section

detail b17

Also see details:b15 monier abutment detail for framed penetration.dwgb16 monier elevation-section view of three sided penetration.dwgb17 monier cross section of hidden gutter.dwg for details

See cross section detail b15

Page 29: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

2726

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B15 ABUTMENT DETAIL FOR FRAMED PENETRATION

Cladding lap over upstandCladding

Nog for upstand

Bottom of gutter to dischargeinto side hidden gutter (then into

spouting) see detail b17

Gutter board at abutmenton nogs to suit

75m

m M

in L

ap

Cladding cavity

Butyl, EPDM lining carried overanti-ponding board and up

abutment frame on nog to suit.Dress around sides of

penetration at ends

250mm anti-ponding board laidto fall - See note *

Underlay

Monier tile

Tile batten

100mm min

50m

m m

in D

eep

* Note:Anti-ponding boards – to be fitted in accordance with E2/AS1,8.2.5Masonry roofs with pitches less than 17° shall have anti-ponding boards installed. Where anti-ponding boards are used, these shallbe set to a minimum fall of 5° towards the fascia and shall be treated in accordance with NZS 3602.

To designer's specification butcladding must finish 50mmminimum above gutter lining

Also see details:b14 monier plan view of three sided penetration.dwgb16 monier elevation-section view of three sided penetration.dwgb17 monier cross section of hidden gutter.dwg for details

Cross Section BB(from B14 Monier Plan View Of Three Sided Penetration)

B16 ELEVATION/SECTION VIEW OF THREE SIDED PENETRATION

Fascia board

Rafter

Monier tile

Chimney

Hidden gutter discharginginto gutter

Gutter

See detail mt15 for further information

Also see details:b14 monier plan view of three sided penetration.dwgb15 monier abutment detail for framed penetration.dwgb17 monier cross section of hidden gutter.dwg for details

Page 30: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

28

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

B17 CROSS SECTION OF HIDDEN GUTTER

Monier tile

Cladding

Tile Batten

Underlay where required

Rafter

100m

m200m

m m

in.

Support Nog

Cladding cavity

Edge Batten

Cross Section A-A(from b14 Monier Plan View Of Three Sided Penetration)

E2/AS1 Approvedmembrane on substrate

Also see details:b14 monier plan view of three sided penetration.dwgb15 monier abutment detail for framed penetration.dwgb16 monier elevation-section view of three sided penetration.dwg for details

100mm min

B18 PIPE PENETRATION DETAIL

Stack/vent pipe withventing cap carried

through tile

Acrylead / Lead carried to topedge of the tile under the

overlap

Monier Concrete Tiles

Dress Acrylead / Lead sleeve100mm up pipe and solder toAcrylead / Lead flashing over tileCollar sealed to pipe over

Acrylead / Lead flashing

Acrylead / Lead flashing dressedto roof tile min 150mm all round

and carried up to edge of tile

Acrylead / Lead dressed downover bottom edge of tile or150mm, whichever is less

Page 31: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

2928

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT17 CROSS SECTION HIDDEN GUTTER - FLAT TILE

MonierHorizon tile

Cladding

Tile Batten

Underlay whererequired

Rafter - double toaccommodate flashingand batten

100m

m

200m

m m

in.

Support Nog

Cladding cavity

Edge Batten

Abutment underflashing

50m

m

50mm

50m

m

50m

m 200m

m

Abutment flashingdimensions

Abutment flashingextension to continuethrough to centre line

Building wrap

Acrylead / Lead

MT18 CHIMNEY TRAY

Weep hole

Over flashing

Back gutter

Monier tile

Boarding block tosupport back gutter

Tile batten

Rafter

Stop flashing

Chimney tray

Chimney tray

Page 32: ARCHITECTURAL DRAWINGS - Monier · ARCHITECTURAL DRAWINGS USE OF ARCHITECTURAL DRAWINGS Monier roofing systems provide contemporary and innovative design solutions that benefit from

AR

CH

ITE

CTU

RA

L D

RA

WIN

GS

30

NOT TO SCALE. ALL TECHNICAL FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE 1.

MT19 CHIMNEY FLASHING

Over flashing

Back gutter

Monier tile

Boarding block tosupport back gutter

Tile batten

Rafter

Stop flashing

MT20 PIPE PENETRATION DETAIL - FLAT TILE

Stack/vent pipe withventing cap carried

through tile

Acrylead / Lead carried to top edgeof the tile under the overlap

(upper tiles lifted to illustrate)

Monier tiles

Dress Acrylead / Lead sleeve100mm up pipe and solder tolead flashing over tile

Collar sealed to pipe overAcrylead / Lead flashing

Acrylead / Lead flashing dressed toroof tile min 150mm all round and

carried up to edge of tileAcrylead / Lead dressed downover bottom edge of tile or150mm, whichever is less

Apply silicon to completeperimeter of opening before fittingAcrylead / Lead flashing