Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories...

35
Handing Chart Architectural Accessories Details Wood Door Technical Manual May, 2017 Index Contents Construction Detail ............................................................................................................................................... 2 Wood Moulding .................................................................................................................................................. 3-4 Louver Unites - Wood and Metal .................................................................................................................... 5 Vision Panels - Wood and Metal ...................................................................................................................... 6 Factory Installed Glass..................................................................................................................................... 7-9 Astragals/Edges ................................................................................................................................................... 10 Dutch Door ......................................................................................................................................................... 11-16 Doors with Transoms (Non Fire-Rated) ................................................................................................. 17-18 Doors with Transoms (Fire-Rated) ......................................................................................................... 19-22 Wicket Door ........................................................................................................................................................... 23 Special machining - Rabbiets/Radius Edge .............................................................................................. 24 Flush Bolts .............................................................................................................................................................. 25 Fire Door Plant-Ons ............................................................................................................................................ 26 Full Glass / Full Warranty Door ...................................................................................................................... 27 ElectroLynx ............................................................................................................................................................ 28 Door Glazing Charts ..................................................................................................................................... 29-31 Wood Frames ................................................................................................................................................. 32-35 ARCHITECTURAL Wood Doors | Maiman Architectural Accessories Details Wood Door Technical Manual

Transcript of Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories...

Page 1: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

May, 2017

Index Contents

Construction Detail ............................................................................................................................................... 2

Wood Moulding ..................................................................................................................................................3-4

Louver Unites - Wood and Metal .................................................................................................................... 5

Vision Panels - Wood and Metal ...................................................................................................................... 6

Factory Installed Glass ..................................................................................................................................... 7-9

Astragals/Edges ................................................................................................................................................... 10

Dutch Door ......................................................................................................................................................... 11-16

Doors with Transoms (Non Fire-Rated) ................................................................................................. 17-18

Doors with Transoms (Fire-Rated) ......................................................................................................... 19-22

Wicket Door ...........................................................................................................................................................23

Special machining - Rabbiets/Radius Edge ..............................................................................................24

Flush Bolts ..............................................................................................................................................................25

Fire Door Plant-Ons ............................................................................................................................................26

Full Glass / Full Warranty Door ......................................................................................................................27

ElectroLynx ............................................................................................................................................................28

Door Glazing Charts ..................................................................................................................................... 29-31

Wood Frames ................................................................................................................................................. 32-35

ARCHITECTURAL

Wood Doors | Maiman

Architectural Accessories DetailsWood Door Technical Manual

Page 2: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

July, 2016

Construction DetailsArchitectural Accessories DetailWood Door Technical Manual

Meeting Edge Options

No Bevel Bevel

Rabbeted Parallel BevelDbl. Egress

Flat AstragalMetal EdgeGuards/Astragal

Metal EdgeGuards

Glazing Options

Standard Minimums

All cutouts for metal or wood vision panels must be a minimum of 5” (152 mm) from the edge of the door and/or other cutouts for louvers, locks, closers or other hardware.

This 5” (152 mm) distance must be maintained or the fire label and warranty will be voided. For non-fire rated doors, the distance may be decreased to 5” (127 mm). Less than 5” (127 mm) may affect the warranty

Using a 10” (254 mm) margin between the edge of the door and the edge of any cutout near the lock area will eliminate most label and warranty conflicts.

* A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of com-ponents.

** Lip mouldings only are available for Thermal Fused Doors.

Flush Mouldings*

Lip Mouldings**

2

Page 3: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 May, 2018

Wood MouldingsArchitectural Accessories DetailWood Door Technical Manual

1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick doors

M2G - Flat Lip Moulding 15/16” wide x 5/8” thick, 3/32” radius. M3G - Beveled Lip Moulding 15/16” wide x 3/4” thick, 3/32” radius2. Wire Brad - Lip Moulding is factory attached.3. 1/4” Glazing - Glazing materials are not included.4. Beveled back for glazing compound or 1/16” tape (not included).5. Lights - Order size - visible glass size Cutout size = visible glass + (2 x moulding profile) Glass size = cutout - 1/4” wide - 1/4” high

Lip Moulding for Lights

General Moulding Requirements

Flush Moulding for Lights

3

2

115/16”

11/16”

3/8”

3/32”

3/32”

3/8”

11/16”

M2G M3G

M6G

4

5/8”

15/16”

3/32”

11/16”

1/2”3/4”

3

2

1

4

1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick doors

M6G - Flush Moulding 11/16” wide x 3/8” thick, 3/32” radius. 2. Wire Brad - Flush Moulding is factory attached.3. 1/4” Glazing - Glazing materials are not included.4. Beveled back for glazing compound or 1/16” tape (not included).5. Lights- Order size - visible glass size Cutout size = visible glass + (2 x moulding profile) Glass size = cutout - 1/4” wide - 1/4” high

Species shall match or be compatible with face veneer or laminateMoulding shall be free of open defects, shake, splits, or dozeMoulding must be smooth and free of visible knife, saw or sanding marks

A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of components.

3

Page 4: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2017

4

Wood MouldingsArchitectural Accessories DetailWood Door Technical Manual

Fire Rated Flush Wood Moulding for Lights

1. Available with 45, 60 and 90 minute fire rated (mineral core) doors.

2. Factory installed: glass, glazing material, glazing bead, clips, nails, provided.3. Flush Moulding Profile: MF34. Available Species: Red Oak, Natural Birch, White Maple, Cherry, Mahogany, and

Walnut. Contact you Customer Service Professional for availability of other species.5. Glass: 1/4” thick nominal wired glass (100 in2 maximum) or 3/16” thick nominal

ceramic (1296 in2 maximum)6. Cutout Size and Glass Size: Cutout Width = Visible Glass Width + 1.563” Cutout Height = Visible Glass Height + 1.563” Glass Width = Visible Glass Width + 1.375” Glass Height = Visible Glass Height + 1.375”

A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of components.

Distance from light Cutout to:

Hourly Rating Area (in2)

Width (inch)

Height (inch) Multiple Lights

Door Edge (inch)

Hardware Prep Cutout

(inch)

Light Cutouts (inch)

45-90 Minute* 1296 36 54 Yes, sum of areas < 1296 in2 5 1.313 5

3/4”

MF3

*The International Building Code (IBC) states that fire protection rated glazing in excess of 100 in2 is not permitted in 60 and 90 minute fire rated doors. NFPA 80 states that glazing materials in vision panels shall be installed in accordance with inspection service procedure and under label service.

Page 5: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

5

Louver UnitsArchitectural Accessories DetailWood Door Technical Manual

1. L100 Wood Non-Vision Louver Unit - 3/4” wide, 33% free air movement. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick doors. Specify louver size the same as cutout size. 1-3/8” thick doors require framed louvers. Louvers may not be installed in 20 minute fire doors.

M2W - Flat Lip Moulding 11/16” wide x 5/8” thick, 3/32” radius. M6W - Flush Moulding 7/16” wide x 3/8” thick, 3/32” radius2. Wire Brad - Mouldings are factory attached. Louvers

are not factory installed as standard. Louvers may be facorty installed as an option.

3. Field installation may require the use of glazing tape for proper fit.

V-Slat Wood Louver

1. L600 Metal Non-Vision Louver Unit - 1-1/16” wide, 20 gauge steel, 50% free air movement. For use with 1-3/4” thick doors. 1-3/8” thick doors require framed louvers. Louver cutout is 1/8” less then order size. Louvers may not be installed in 20 minute fire doors.

M2M - Flat Lip Moulding 9/16” wide x 5/8” thick, 3/32” radius. M6M - Flush Moulding 5/16” wide x 3/8” thick, 3/32” radius2. Wire Brad - Mouldings are factory attached. Louvers are

not factory installed. Louvers may be facorty installed as an option.

3. Field installation may require the use of glazing tape for proper fit.

V-Slat Metal Louver

1. L1900A Framed Metal Non-Vision Louver Unit - Fire rated fusible link unit for use with 45, 60 or 90 minute fire doors. 1-3/4” wide. 135 degree F fusible link. 40% free air movement. For use with 1-3/4” thick doors only. Not factory installed. Louvers may not be installed in 20 minute fire doors.

2. Steel mounting frame overlaps door face 1”.3. Through bolt applied. Security screws are available by

option.4. Metal fusible link louvers will not be factory installed.

Metal Fusible Link Louver

1

3

2

1/2”

1

2

3

1/2”

1/16”

3

2

1

11/16”

7/16”

5/8”

3/32”

M2W

3/32”

3/8”

7/16”

M6W

5/8”

5/16”

3/32”

9/16”

3/32”

3/8”

5/16”

M6M

M2M

A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of components.

A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of components.

3/4”

Page 6: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

May, 2018

Vision PanelsArchitectural Accessories DetailWood Door Technical Manual

6

1. M110 Metal Vision Frame - Fire rated for 20, 45, 60 and 90 minute fire door applications. 18 gauge steel with mitered, round corners that are braced and welded. Available wood veneer wrapped as an option. Low profile for hardware clearance.

2. Metal frame and glazing support clip.3. Vandal proof binder screw.4. For 1/4” thick listed glazing (not included).Note: No glazing compound or tape is required. Not factory installed.5. Fire rated metal vision panels will be factory installed.6. Lights - Order size = visible glass size Cutout size = visible glass size + 1-1/2” side + 1-1/2” high Glass size = visible glass size + 3/4” wide + 3/4” high7. Listed for UL 10B and UL 10C.

Note: Custom shapes for specialty lights must be specified for visible glass size and cutout size.

Fire Rated Metal Vision Panel

1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick 20 minute rated fire doors.

M3F - Beveled Lip Moulding 15/16"wide x 5/8" thick, 3/32" radius. M6F - Flush Moulding 11/16" wide x 1/2" thick, 1/8" radius.2. Glazing compound or tape required for proper fit.3. For 1/4” or 3/16" (two layers of glazing required on one side of the

door) thick listed glazing (not included). Size are visible glass size. Cutouts are 1” larger in width and height. Custom shapes for specialty lights must be specified for visible glass size and cutout size.4. Lights - Order size = visible glass size Cutout size = visible glass size + (2 x moulding profile) Glass size = cutout - 1/8” wide - 1/8” high5. Listed for UL 10B and UL 10C.

Note: Custom shapes for specialty lights must be specified for visible glass size and cutout size.

20 Minute Moulding for Lights

1

4

1 32

1

3

3

2

2

M6F

1/8”

1/2”

11/16”

1/2” 3/4”

15/16”

3/32”

11/16”

M3F

A variance in the downset of flush mouldings may occur due to allowable tolerance deviations of components.

Page 7: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

Factory Installed GlassArchitectural Accessories DetailWood Door Technical Manual

7

RATINGMAXIMUM

EXPOSED AREAMAXIMUM

WIDTHMAXIMUM

HEIGHTCORE TYPE

20, 45 1296 36 54Mineral, Particleboard, Engineered

Composite, Agrifiber

20, 45 2550 34 75Mineral, Particleboard, Engineered

Composite

60* 900 12 75 Mineral

60* 864 24 36 Mineral

60, 90 1296 24 54 Mineral

Temp Rise 100 12 33 Mineral

** Glazing tape required for all fire rated applications

KERALITE® LAMINATED GLASS DESCRIPTION

FIRE RATING 20-90 MINUTE US TESTING LISTED AND LABELED WITH UNDERWRITERS LABORATORIES INC. FILE #R14515 TESTED IN ACCORDANCE WITH UL 9, UL 10B, UL 10C, NFPA 80, NFPA 252, NFPA 257 CANADIAN TESTING CAN/ULC-S106, S104 IMPACT SAFETY RATING CPSC 16CFR PART 1201 (CATEGORIES I & II). ANSI Z97.1, CAN/CGSB-12.1-M NOMINAL THICKNESS 5/16” (8 MM) THICKNESS TOLERANCE +1/64” TO -1/64” (+0.4 MM TO -0.4 MM) U VALUE BTU/(HR*SQFT*DEGF) 0.88 WEIGHT (LBS/SQ FT.) 4.1 APPROX. VISIBLE LIGHT TRANSMISSION 82%

RATINGMAXIMUM

EXPOSED AREAMAXIMUM

WIDTHMAXIMUM

HEIGHTCORE TYPE

20, 45 1296 36 54Mineral, Particleboard, Engineered

Composite, Agrifiber

20, 45 2550 34 75Mineral, Particleboard, Engineered

Composite

60* 900 12 75 Mineral

60* 864 24 36 Mineral

60, 90 1296 24 54 Mineral

Temp Rise 100 12 33 Mineral

** Glazing tape required for all fire rated applications

KERALITE® FILMED

GLASS DESCRIPTION

FIRE RATING 20-90 MINUTE US TESTING LISTED AND LABELED WITH UNDERWRITERS LABORATORIES INC. FILE #R14515. TESTED IN ACCORDANCE WITH UL 9, UL 10B, UL 10C, NFPA 80, NFPA 252, NFPA 257 CANADIAN TESTING CAN/ULC-S106, S104 IMPACT SAFETY RATING CPSC 16CFR PART 1201 (CATEGORIES I & II), ANSI Z97.1, CAN/CGSB-12.1-M NOMINAL THICKNESS 3/16” (5 MM) THICKNESS TOLERANCE +1/64” TO -1/64” (+0.4 MM TO -0.4 MM) U VALUE BTU/(HR*SQFT*DEGF) 0.88 WEIGHT (LBS/SQ FT.) 2.4 APPROX. VISIBLE LIGHT TRANSMISSION 86%

Page 8: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

8

Factory Installed GlassArchitectural Accessories DetailWood Door Technical Manual

FIRELITE® NT (FIG05) Glass Description

CERAMIC, FILMED FIRE AND SAFETY RATED GLASS BRAND: FIRELITE NT GRADE: PREMIUM THICKNESS: 3/16” NOMINAL WARRANTY: 3 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II

FIRE LISTINGS

UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITHINTERNATIONALBUILDING CODE SECTION 715.4.6 AND 2406

NOTES RATING MAXIMUMEXPOSED AREA

MAXIMUM WIDTH

MAXIMUM HEIGHT CORE TYPE

20, 45 1296 36 54 Mineral, Particleboard, Engineered Composite, Agrifiber

1 20, 45 2856 34 84 Mineral, Particleboard, Engineered Composite

2 60* 960 12 80 Mineral

2 60* 864 24 36 Mineral

2 60, 90 1296 24 54 Mineral

Temp Rise 100 12 33 Mineral

* 2 lights max1 Same as above PEMKO FG30008452 Same as above PEMKO FG3000890

FIRELITE® PLUS (FIG06)

Glass Description

CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS BRAND: FIRELITE PLUS GRADE: PREMIUM THICKNESS: 5/16” NOMINAL WARRANTY: 5 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II

FIRE LISTINGS

UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITHINTERNATIONALBUILDING CODE SECTION 715.4.6 AND 2406

NOTES RATING MAXIMUMEXPOSED AREA

MAXIMUM WIDTH

MAXIMUM HEIGHT CORE TYPE

20, 45 1296 36 54 Mineral, Particleboard, Engineered Composite, Agrifiber

1 20, 45 2856 34 84 Mineral, Particleboard, Engineered Composite

2 60* 960 12 80 Mineral

2 60* 864 24 36 Mineral

2 60, 90 1296 24 54 Mineral

Temp Rise 100 12 33 Mineral

* 2 lights max1 Same as above PEMKO FG30008452 Same as above PEMKO FG3000890

Page 9: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

Factory Installed GlassArchitectural Accessories DetailWood Door Technical Manual

9

1/4” TEMPERED (FIG01)

Glass Description

1/4” CLEAR TEMPERED IMPACT SAFETY RATED GLASS QUALITY RATING: Q3, ASTM C1036-06 THICKNESS: 1/4” NOMINAL WARRANTY: 1 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II

GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 2406

NOT FOR USE ON FIRE RATED DOORS

1/4” FILMED WIRE (FIG02)

Glass Description

1/4” FILM WIRE, FIRE AND IMPACT SAFETY RATED GLASS QUALITY RATING: Q3, ASTM C1036-06 THICKNESS: 1/4” NOMINAL WARRANTY: 1 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II

FIRE LISTINGS

UL AND INTERTEK/WARNOCK-HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITHINTERNATIONALBUILDING CODE SECTION 715.4.6 AND 2406

RATINGMAXIMUMEXPOSED

AREA

MAXIMUM WIDTH

MAXIMUM HEIGHT CORE TYPE

20, 45 1296 36 54 Mineral, Particleboard, Engi-neered Composite, Agrifiber

60, 90 * 300 15 33 Mineral

Temp Rise 100 12 33 Mineral

* Non Temp Rise

Page 10: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

Astragals/EdgesArchitectural Accessories DetailWood Door Technical Manual

10

1. A1 Wood Astragal - 2” wide, 1/2” thick, 1/4” radius on face edges. Matching specie to door face veneer for Premium grade. For use with 1-3/4” or 1-3/8” thick doors.

2. May be applied using wood screws and adhesive.3. Not for use on any 45, 60 or 90 minute fire rated doors. Flat

wood astragals may be applied to 20 minute neutral pressure tested pairs with Firestop metting edges.

Flat Wood Astragal

1. M207. metal Edge Set With Overlapping Astragal - 16 gauge welded astragal overlaps meeting edge 1”. Approved for 20, 45, 60 and 90 minute fire door applications. Available wood veneer wrapped as an option. May be specified unmachined or machined for builders hardware.

2. 20 gauge wrap-around metal edge overpals meeting stile 1”.3. Phillips Flat head Screws - #8 x 3/4” 12” on center (included).

Note: Overlapping astragals are no longer required for fire rated pairs.

Metal Astragal & Edge

1. M208 Double Metal Edge Set - 20 gauge wrap-around metal edge overlaps metting stiles of doors 1”. Approved for 20, 45, 60 and 90 minute fire door applications. Available wood veneer wrapped as an option. may be specified unmachined or machined for builders hardware.

2. Phillips Flat head Screws - #8 x 3/4”, 12” on center (included). Note: Double metal edges are no longer required on 20, 45, 60 or 90 minute paris if doors are specified to be without metal edges. Requires special interior blocking profiles.

3. Also available with 5” wrap-around metal edges for use with the application of concealed vertical rod exit devices in the M250 series.

Double Metal Edge

1

1 2

3

2

1

Page 11: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 May, 2018

Dutch Door (Non Fire Rated)Architectural Accessories DetailWood Door Technical Manual

11

1. Allow for shelf thickness when specifying hardware.2. Standard shelf is 1.125” (28 mm) thick wood, 1 side only.3. Standard wood shelf sits between leaves.4. Shelf and supports are not factory installed5. Note if shelf is not required.6. Note if other than standard shelf is required.7. Dutch doors are available in GPD or GCD bonded consturction

only.8. GPD has matching top rail in bottom leaf. GCD has non-

matching top rail in bottom leaf.9. Dutch doors are available in single openings up to 4’0” x 9’0”.

Dutch doors are available in paired openings up to 8’0” x 9’0”.

General Notes

3/16”

Hei

ght

By

Sp

ecifi

cati

on

Hei

ght

By

Sp

ecifi

cati

on

(inc

lud

es s

helf

)

Shelf

8”

1-3/4”

Shelf Bracket

4”

4”

1-1/8”

Page 12: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

Dutch Door (Non Fire Rated)Architectural Accessories DetailWood Door Technical Manual

12

1. Dutch doors may be provided with: a. Straight cut metting edges of top and bottom leaf. b. Rabbeted metting edges of top and bottom leaf.2. Standard clearnace between top leaf and

bottom leaf of Dutch doors is 3/16”.3. Dutch door latching may be cylindrical, mortise

or flushbolt latches that latch: a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame.

General Notes NON RATED DUTCH DOOR

TOP LEAF

2” Wood Rails (Min.)

1-1/8” Wood Shelf

2” Wood Rails (Min.)

BOTTOM LEAF

EXAMPLE OF LATCHING CONFIGURATION

PAIR OF DUTCH DOORS

TOP LEAF TOP LEAF

BOTTOM LEAF BOTTOM LEAF

ACTIVE LEAF INACTIVE LEAF

Page 13: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

13

Dutch Door (20 Minute Fire Rating)Architectural Accessories DetailWood Door Technical Manual

1. Allow for shelf thickness when specifying hardware.2. Standard shelf is 1.125” (28 mm) thick wood, 1 side only.3. Standard wood shelf sits between leaves.4. Shelf and supports are not factory installed5. Note if shelf is not required.6. Note if other than standard shelf is required.7. Dutch doors are available in GPD or GCD bonded

consturction only.8. GPD has Firestop bottom rail in top leaf. Firestop top rail

in bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop top rail in bottom leaf.

9. Dutch doors are not available in 90 minute neutral pressure tested construction.

10. Positive pressure fire tested Dutch door constructions are not available.

11. Dutch doors are available in 20 minute fire rated single openings up to 4’0” x 8’0”.

12. Dutch doors are available in 20 minute fire rated paired openings up to 8’0” x 8’0”.

General Notes

1/8”

Hei

ght

By

Sp

ecifi

cati

on

Hei

ght

By

Sp

ecifi

cati

on

(inc

lud

es s

helf

)

Shelf

8”

1-3/4”

Shelf Bracket

4”

4”1-1/8”

Page 14: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

14

Dutch Door (20 Minute Fire Rating)Architectural Accessories DetailWood Door Technical Manual

1. 20 minute Dutch doors may be provided with one of these:

a. An overlapping astragal applied to the bottom rail of the top leaf b. Intumescent fire seal installed in the bottom rail of the top leaf. c. Standard wood shelf sits between leaves.2. A maximum 1/8” (3.2 mm) clearance between top

leaf and bottom leaf of fire rated Dutch doors is allowed.

3. Fire rated Dutch doors require both leaves to be self latching. Leaf to leaf or leaf to frame.

4. Fire rated Dutch door latching is limited to cylindrical or mortise latches that latch:

a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame.5. Flushbolts are allowed on the inactive leaves of a

pair.

General Notes 20 MINUTE DUTCH DOOR

TOP LEAF

2” wide Firestop Rails (Min.)

1-1/8” Wood Shelf

BOTTOM LEAF

Intumescent

2” wide Firestop Rails (Min.)

EXAMPLE OF LATCHING CONFIGURATION

PAIR OF DUTCH DOORS

TOP LEAF TOP LEAF

BOTTOM LEAF BOTTOM LEAF

ACTIVE LEAF INACTIVE LEAF

Page 15: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

15

Dutch Door (45/60 Minute Fire Rated)Architectural Accessories DetailWood Door Technical Manual

1. Allow for shelf thickness when specifying hardware.2. Standard shelf is 1.125” (28 mm) thick wood, 1 side only.3. Standard wood shelf butts to face of bottom leaf.4. Shelf and supports are not factory installed5. Note if shelf is not required.6. Note if other than standard shelf is required.7. Dutch doors are available in GPD or GCD bonded consturction

only.8. GPD has Firestop bottom rail in top leaf. Firestop top rail in

bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop top rail in bottom leaf.

9. Dutch doors are not available in 90 minute neutral pressure tested construction.

10. Positive pressure fire tested Dutch door constructions are not available.

11. Dutch doors are available in 45/60 minute fire rated single openings up to 4’0” x 8’0”.

12. Dutch doors are not available in 45/60 minute fire rated paired openings.

General Notes

1/8”

Hei

ght

By

Sp

ecifi

cati

on

Hei

ght

By

Sp

ecifi

cati

on

(inc

lud

es s

helf

)

Shelf

8”

1-3/4”

Shelf Bracket

4”

4”1-1/8”

Page 16: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

16

Dutch Door (45/60 Minute Fire Rated)Architectural Accessories DetailWood Door Technical Manual

1. 45/60 minute Dutch doors may be provided with one of these:

a. An overlapping astragal applied to the bottom rail of the top leaf b. Intumescent fire seal installed in the bottom rail of the top leaf. c. Standard wood shelf sits between leaves.2. A maximum 1/8” (3.2 mm) clearance between top leaf

and bottom leaf of fire rated Dutch doors is allowed.3. Fire rated Dutch doors require both leaves to be self

latching. Leaf to leaf or leaf to frame.4. Fire rated Dutch door latching is limited to cylindrical or

mortise latches that latch: a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame.

General Notes 45/60 MINUTE DUTCH DOOR

TOP LEAF

2” wide Firestop Rails (Min.)

1-1/8” Wood Shelf

BOTTOM LEAF

Intumescent

2” wide Firestop Rails (Min.)

EXAMPLE OF LATCHING CONFIGURATION

TOP LEAF TOP LEAF

BOTTOM LEAF BOTTOM LEAF

Page 17: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 November, 2016

1. Doors with transoms are available with or without frame transom bars in single or paired openings.

2. Meeting edges of transoms and doors in openings without transom bars may be straight cut or rabbeted. See standard rabbet detail.

3. Doors with transoms are available in GPD and GCD bonded constructions only.4. GPD has matching rails at bottom of transom and top of door. GCD has 5. non-matching rails at bottom of transom and top of door.6. Spring bolts are required for installation of transom panels. To receive lifetime warranty

on doors and transoms, springbolts must be placed a minimum of 2” (51 mm) from each corner.

Panels up to 18” (458 mm) in height require 2 springbolts per side. Panels up to 36” (916 mm) in height require 3 springbolts per side. Panels up to 40” (1220 mm) in height require 4 springbolts per side.7. Doors with transoms are available in single openings up to 4’0” x 10”0”. Maximum

transom panel size in a single opening up to 4’0” wide x 3’4” high. Doors with transoms are available in paired openings up to 8’0” x 10’0”. Maximum transom panel size is a paired opening is 8’0” wide x 3’4” high.

Non-rated Doors with Transoms

Doors with Transoms (Non-Rated)Architectural Accessories DetailWood Door Technical Manual

17

Page 18: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

November, 2016

18

1. Doors with transom may be provided with: a. Straight cut meeting edges of door and transom with an over lapping astragal optional. b. Straight cut meeting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom.2. A maximum 1/8” (3.2 mm) clearance between

door and transom is allowed in non-rabbeted applications.

3. Transom panels must be installed using springbolts placed a minimum of 2” (51 mm) from each corner.

Non-Rated Doors with Transoms

NON RATED DOOR WITH TRANSOM

Solid Wood Cores

Transom

1” Wood Rails

1” Wood Rails

Steel Astragals Optional

Solid Wood Cores

1/8” Max. Gap

1/8” Max. Gap

1-3/4”

1” Wood Rails

1” Wood Rails

Transom

Mullion

DOOR WITH TRANSOM IN FRAME WITH MULLION

1-3/4”

Doors with Transoms (Non-Rated)Architectural Accessories DetailWood Door Technical Manual

Page 19: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

Door with Transom (20 Minute Fire Rated)Architectural Accessories DetailWood Door Technical Manual

19

1. Transom panels must be the same construction as the 20 minute fire door.2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge and astragal,

or with a transom bar between the door and transom. Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and transom.3. Transom installed over a pair of 20 minute rated doors must be separated with a frame mullion. The mullion must

limit the width of each separate transom to the width of each leaf of the door pair.4. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The appropriate

number of springbolts will be supplied by the machiner.5. Fire rating labels will be provided on door and transom stating “Door and Transom Assembly.”6. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2”

(51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted tansoms.

Panels up to 18” (458 mm) in height require 2 springbolts per side. Panels up to 36” (916 mm) in height require 3 springbolts per side. Panels up to 40” (1220 mm) in height require 4 springbolts per side.7. Maximum clearance between the frame and panel must be 1/8” (3.2 mm).8. Doors with transoms are available in single openings up to 4’0” x 10”0”. Maximum transom panel size in a single

opening up to 4’0” wide x 3’4” high. Doors with transoms are available in paired openings up to 8’0” x 10’0”. Maximum transom panel size is a paired opening is 8’0” wide x 3’4” high. Transom panels above pairs of doors must be separated by a mullion.

20 Minute Fire Rated Doors with Transoms

Page 20: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

Door with Transom (20 Minute Fire Rated)Architectural Accessories DetailWood Door Technical Manual

20

1. Neutral pressure tested fire doors with transoms may be provided with:

a. Straight cut meeting edges of door and transom with an over lapping astragal. b. Straight cut metting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom.Positive pressure tesed fire doors with transoms must be installed in a frame with transom bar between the door and transom.2. A maximum 1/8” (3.2 mm) clearance between

door and transom is allowed in non-rabbeted applications. Maximum clearance between the frame and transom panel must be 1/8” (3.2 mm).

3. Fire rated Transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2” (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted transoms.

Panels up to 18” (458 mm) in height require springbolts per side. Panels up to 36” (916 mm) in height require springbolts per side. Panels up to 40” (1220 mm) in height require

4 springbolts per side.

20 Minute Doors with Transoms

Solid Wood Cores

Transom

1” Wide Firestop Rails Min.

Steel Astragals

Solid Wood Cores

1/8” Max. Gap

1/8” Max. Gap

1-3/4”

Transom

Mullion

20 MINUTE DOOR WITH TRANSOM IN FRAME WITH MULLION

1” Wide Firestop Rails Min.

1” Wide Firestop Rails Min.

1” Wide Firestop Rails Min.

1-3/4”

Page 21: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

45/60/90 Minute Fire Rated Doors with TransomsArchitectural Accessories DetailWood Door Technical Manual

21

1. Transom panels must be the same construction as the 20 minute fire door.2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge and

astragal, or with a transom bar between the door and transom. Rabbeted door and transom assemblies must be constructed with minimum 5” (127 mm) Firestop bottom rail of transom and top rail of door. The rabbet must be a minimum 1/2” (13 mm) deep x 7/8” (22 mm) wide.

Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and transom.3. If an overhead door closer is to be installed the bottom rail of the transom and the top rail of the door must be 5”

(127 mm) Firestop. When transom bar is provided the rails shall be standard Firestop or Firestop II material.4. Transom installed over a pair of fire rated doors must be separated with a frame mullion. The mullion must limit

the width of each separate transom to the width of each leaf of the door pair.5. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The appropriate

number of springbolts will be supplied by the machiner.6. Fire rating labels will be provided on door and transom stating “Door and Transom Assembly.”7. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be placed

2” (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts.

Panels up to 18” (458 mm) in height require 2 springbolts per side. Panels up to 36” (916 mm) in height require 3 springbolts per side. Panels up to 40” (1220 mm) in height require 4 springbolts per side. Maximum clearance between the frame and panel must be 1/8” (3.2 mm).8. Neutral pressure tested fire doors with transoms are available in single openings up to 4’0” x 10”0”. Positive pressure tested fire doors with transoms are available in single openings up to 4’0” x 9”0”. Neutral pressure tested fire doors with transoms are available in paired openings up to 8’0” x 10”0”. Positive pressure tested fire doors with transoms are available in paired openings up to 8’0” x 9”0”. Maximum transom panel size in a single opening up to 4’0” wide x 3’4” high. Maximum transom panel size in a paired opening is 4’0” wide x 3’4” high. Transom panels above pairs of doors must be separated by a mullion.

45/60/90 Minute Fire Rated Doors with Transoms

Page 22: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

22

Doors with Tramsoms (45/60/90 Minute Fire Rated)Architectural Accessories DetailWood Door Technical Manual

1. Neutral pressure tested fire doors with transoms may be provided with:

a. Straight cut meeting edges of door and transom with an over lapping astragal. b. Straight cut metting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom. Rabbeted meeting edges require 5” (127 mm) bottom rail of tramson and top rail of door. Positive pressure tesed fire doors with transoms must be installed in a frame with transom bar between the door and transom.2. A maximum 1/8” (3.2 mm) clearance between door

and transom is allowed in non-rabbeted applications. Maximum clearance between the frame and transom panel must be 1/8” (3.2 mm).

3. Fire rated Transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2” (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted transoms.

Panels up to 18” (458 mm) in height require 2 springbolts per side. Panels up to 36” (916 mm) in height require 3

springbolts per side. Panels up to 40” (1220 mm) in height require 4 springbolts per side.

45/60/90 Minute Doorswith Transoms

Transom

5” Wide Firestop Rails Min.

Steel Astragals

1/8” Max. Gap

1/8” Max. Gap

1-3/4”

Transom

Mullion

45/60/90 MINUTE DOOR WITH TRANSOM IN FRAME WITH MULLION

G-P Firestop Composi-tion 1” Wide Firestop

Rails Min.

G-P Firestop Compo-sition 1” Wide Firestop

Rails Min.

5” Wide Firestop Rails Min.

1-3/4”

Page 23: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

Wicket Doors (Standard)Architectural Accessories DetailWood Door Technical Manual

23

1. Requires handing of call door and wicket door2. Latch/lock for call door must be suitable for rabbeted

application3. Shelf and call door are not factory installed4. Available in GPD or GCD bonded constructions only5. SCLC (EC) core required

General Notes

Shelf

8”

1-3/4”

4”

4”

9/16”

2”

Shelf Bracket

13/16”

1-3/4”

Cal

l Do

or

Siz

e

Op

enin

g S

ize

Typical Rabbet

Hinged SideUnrabbeted Rabbeted

1-1/8” Thick Shelf

3/32”Reveal

CallDoor

Shelf

WicketDoor

Page 24: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

24

Special MachiningArchitectural Accessories DetailWood Door Technical Manual

1. Provide non-vision joint between door and transom.2. Non-fire rated wood core door/transom units hae solid matching

hardwood top rail in door and bottom rail in transom.3. Rabbets allow 1/8” spacing between door and transom when door is

in closed position.4. Available on 20-minute rated doors/transoms.5. May be applied to 45, 60 and 90-minute fire doors. Mineral core

fire door/transom units do not have matching rails. requires special construction.

6. Available on 1-3/4” thick doors only.7. Available in GPD or GCD bonded constructions only.Note: GPD has matching bottom rail on top leaf and matching top rail on bottom leaf. GCD has non-matching bottom rail on top leaf and non-matching top rail on bottom leaf.

General Notes

Transom

Door

1. Used on doors when specified using pivot hinges or when double acting door is specified.

2. When specified for application to lock stile, verify lock/latch hardware compatibility. Requires full face stile.

3. When specified for application to hinge stile, verify radius of edge with hardware template requirements.

4. Available on 1-3/4” thick doors only.5. Available in GPD or GCD bonded constructions only.6. Not available on any fire rated door.7. Specify radius on hinge and lock edge.

General Notes

Standard Rabbet

Radius Edge

Convex Concave

2-1/2”1-7/8”1-1/2”

1-5/32”

1-5/32”

Available Radii (R)

Page 25: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 May, 2017

Flush BoltsArchitectural Accessories DetailWood Door Technical Manual

25

Corner mounted flush bolts having mortised cutouts greater than 3/4" wide and 1" deep have a tendency to flare out (flushbolt flare).Flare-out of door corners and any functional problems resulting from hardware preparations requiring removal of core material at door corners is not considered a manufacturing defect under the manufacturer warranty. Delamination or breakage due to mishandling at the corner is common and is not considered a manufacturing defect.If this type of flush bolt is required, Masonite Architecture Wood Doors requires the use of one of the following to maintain warranty on the door.

a. Flush bolt end caps, supplied by others (see detail). End caps are not provided by Masonite Architecture Wood Doors.

b. Astragal/edge set (must be specified on order). Flush bolt end cap. End cap fits over the top rail so the bolt can protrude through the hole.

Top flush bolt on mineral core doors:

Corner mount flush bolts required on fire rated doors must be used in conjunction with manufacture’s required fire listing approvals for use in wood doors. Flush bolts not intended for use in wood doors will not be covered under manufacture warranty.

Cutout Edge View

Flush Bolt

CutoutTop View

Typical flaring problem with corner mount auto flush bolt requiring complete removal of core at corner.

Page 26: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

26

May, 2017

Fire Door Plant-OnsArchitectural Accessories DetailWood Door Technical Manual

Decorative Door Plant-ons are allowed on 20, 45, 60 and 90 minute labeled fire doors. The following conditions apply:1. Type, size and configuration are limited by the door

manufacturer’s tested authorities.2. The plant-ons must be applied under label service at factory

or qulaified distributor. Plant-ons may not be field applied to fire rated doors.

General Notes

1-1/2”

Standard Profiles Offered

1. Masonite Architecture Wood Doors offers the following profiles. Customers may supply assembled plant-ons in other species and profiles, provided they meet the specifications for the intended use listed below. These may also be used on non-fire rated doors.

Minimum spacing to edge of door or cutout.

Minimum spacing between plant-ons.

Minimum enclosed area.

Twice the profile width for width of area..

P-7

9/16”

P-8

1-1/2”

3/4”

P-9

2-3/8”

5/8”

Specifications 20 Minute GP 45/60 Minute GP 90 MinuteMax. Profile Width: 1-3/4” 2-1/2” 2-1/2”

Max. Profile Height 3/4” 3/4” 3/4”

Wood Specie Douglas Fir or Denser Same Same

Attachment Adhesive or Mechanical Adhesive or mechanical Adhesive

Spacing: to edgeof door or cutout 4” 4” 4”

Between Plant-ons Equal or Greater than Profile Same Same

Min. Enclosed Area N/A 2 Time Profile Width & Height 2 Time Profile Width & Height

Coverage Mouldings may not cover in excess of 20% of door face.

Mouldings may not cover inexcess of 22% of door face.

Mouldings may not cover inexcess of 22% of door face.

Page 27: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 May, 2018

Full Glass/Full Warranty DoorArchitectural Accessories DetailWood Door Technical Manual

27

Maximum Size:

Thickness:

Series:

Core:

Rating:

Visible Size:

Glass Thickness:

Mouldings:

Glazing Material:

Moulding Installation:

Warranty:

4’0” wide x 9’0” high

1-3/4” only

GPD, GCD

Wood based particle core

Non-rated or 20 min. only. Fire rated must follow fire listing requirements for glass size and light/lock conflicts

Minimum 8” top rail to visible glassMinimum 6” lock stile and hinge stile to visible glassMinimum 12” bottom rail to visible glass

Maximum 1/4" glass only

M2G (lip), M3G (beveled lip), M6G (flush), M6F (20 min. flush), M3F (20 min. lip), MVP. All moulding is sized for installation with 1/4” glass. Only factory installed glass will have factory installed mould-ing. Factory installed moulding will have nail holes filled. If not factory installed, moulding will ship loose; nail holes will not be filled

Per project specification

For non-rated wood doors, moulding must be installed using 3/32” glazing tape on both sides of the glass and must be fastened every 8” on center using 3d finishing nails (glazing tape and finish nails not provided). For fire rated applications, follow the installation instructions for the listed and labeledlight kit

Not warranted for exterior applications or applications which expose a door to extremes of temperature and/or humidity regardless of the physical placement

6"

12"

8"

Page 28: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

ElectroLynx™ SystemArchitectural Accessories DetailWood Door Technical Manual

28

THE GRAHAM ELECTROLYNX CABLE IS EQUIPPED WITH THE ELECTROLYNX SYSTEM OF PLUG IN CONNECTORS FOR FAST, EASY, CONNECTION TO SIMILARLY EQUIPPED ASSAABLOY HARDWARE. THE ELECTROLYNX CABLE HAS 12 CONDUCTORS OF 22 GA. WIFRE, WITH ELECTROLYNX CONNECTORS. POWER OVER ETHERNET (POE) IS AVAILABLE IF REQUIRED.

AVAILABLE IN GPD & GCD DOORS ONLY

MAXIMUM OF TWO RACEWAYS PER DOOR ON FIRE-RATED DOORS.CAN BE USED IN BOTH NEUTRAL & POSITIVE PRESSURE DOORS CATEGORY A & B

*THE ELECTROLYNX HINGE WILL ALWAYS BE LOCATED IN THE SECOND HINGE FROM THE FLOOR

SINGLECABLE

LOC

K E

DG

E

HIN

GE

ED

GE

VERIFY CABLE LOCATIONBEFORE MODIFYING DOOR OR SURFACE APPLICATION

OF HARDWARE.

HARDWARELOCATION

CL

3/8”

MULTIPLECABLE* LO

CK

ED

GE

HIN

GE

ED

GE

*DOOR MUST BE PREPPED WITH A MINIMUM OF 4 HINGES

FIRE STOP BLOCKINGOR WIDER FIRE STOPSTILE DEPENDING ON

HARDWARE REQUIREMENTS

ELECTRIFIEDTRIM

3 H

ING

E D

OO

R

4 H

ING

E D

OO

R

5 H

ING

E D

OO

R

SINGLECABLE

MULTIPLECABLE

ELECTRICHINGELOCATION

ELECTRICHINGELOCATION

ELECTRICHINGELOCATION

ELECTRICHINGELOCATION

ELECTRICHINGELOCATION

3/8”

Page 29: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 November, 2017

Door Glazing ChartArchitectural Accessories DetailWood Door Technical Manual

29

Fire Rating

(Minutes)Light Kit

Max Size (in2)

Max Width

(Inches)

Max Length

(Inches)

Temp Rise Notes

1/4” Filmed Wire

20 110 1296 36 54 No 20 Wood 1296 36 54 No 45 110 1296 36 54 No Agrifiber and Mineral core only.45 MF3 100 12 33 No Universal (LDF) core only.60 110 300 15 33 No 60 110 100 12 33 Yes 60 MF3 100 12 33 No Universal (LDF) core only.90 110 300 15 33 No 90 110 100 12 33 No 90 MF3 100 12 33 No Universal (LDF) core only.

3/16” Firelite NT, 5/16” Firelite Plus, 3/16” Vetrotech Standard Film, 5/16” Vetrotech Standard Film

20 110 1296* 36 54 No

20 110 2856* 34 84 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Not allowed on Agrifiber core doors.

45 110 1296* 36 54 No Agrifiber and Mineral core only.

45 110 2856* 34 84 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Mineral core only.

45 Wood 1080* 30 36 No Response Engineered core only.45 MF3 1296* 36 54 No Universal (LDF) core only.60 110 300 15 33 No 60 110 100 12 33 Yes

60 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Glazing Tape.

60 110 960* 12 80 NoMaximum 4090 door. Must use Pemko FG3000S90 Glazing Tape. (Two light maximum, 960 in2 each, 12” maximum width).

60 MF3 1296* 36 54 No Universal (LDF) core only.90 110 300 15 33 No90 110 100 12 33 Yes

90 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Glazing Tape.

90 MF3 1296* 36 54 No Universal (LDF) core only.

* Multiple Lights Allowed

General Notes:• All glass must be fire rated and safety impact rated.

Page 30: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

November, 2017

30

General Notes:• All glass must be fire rated and safety impact rated.

Fire Rating(Minutes)

Light Kit

Max Size (in2)

Max Width

(Inches)

Max Length(Inches)

Temp Rise Notes

3/16" Pyran Platinum F

20 110 1296* 36 54 No

20 Wood 1296* 36 54 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Not allowed on Agrifiber core doors.

45 110 1296* 36 54 No Agrifiber and Mineral core only.

45 110 2550* 34 75 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Mineral core only.

45 MF3 1296* 36 54 No Universal (LDF) core only.60 110 300 15 33 No 60 110 100 12 33 Yes

60 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Glazing Tape.

60 110 900* 12 75 NoMaximum 4090 door. Must use Pemko FG300S90 Glazing Tape. (Two light maximum, 900 in2 each, 12" maximum width).

60 MF3 100 12 33 No Universal (LDF) core only.90 110 300 15 33 No 90 110 100 12 33 Yes

90 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Glazing Tape.

90 MF3 1296* 12 33 No Universal (LDF) core only.

3/8" Pyran Platinum L

20 110 1296 36 54 No

20 110 2550* 34 75 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Not allowed on Agrifiber core doors.

45 110 1296 36 54 No Agrifiber and Mineral core only.

45 110 2550* 34 75 No Maximum 4090 door. Must use Pemko FG3000S45 Gla-zing Tape. Mineral core only.

60 110 300 15 33 No 60 110 100 12 33 Yes

60 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Gla-zing Tape.

60 110 960* 12 75 NoMaximum 4090 door. Must use Pemko FG3000S90. Glazing Tape. (Two light maximum, 960 in2 each, 12” maximum width).

90 110 300 15 33 No90 110 100 12 33 Yes

90 110 1296* 24 54 No Maximum 4090 door. Must use Pemko FG3000S90 Glazing Tape.

* Multiple Lights Allowed

Door Glazing ChartArchitectural Accessories DetailWood Door Technical Manual

Page 31: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 November, 2017

31

Core Rating (Minutes)

Minimum Light/Lock Distance

Maximum Light/Lock Distance

Minimum Light/Door

EdgeParticleboard (PC) None 1-1/2" 3-5/16" 5"

Particleboard (PC) 20 1-1/2" 4" 4"

Agrifiber (AF) 20 1-1/2" 4" 4"

Lead Line (LE) None 1-1/2" 3-5/16" 5"

Lead Line (LL) 20 1-1/2" 5" 5"

Agrifiber (AF) 45 4" 4" 4"

Engineered (EC) None 1-1/2" 3-5/16" 5"

Engineered (EC) 20 1-1/2" 4" 4"

Response Engineered (RC) 45 4" 4" 4"

G.P. White Mineral (FD) 45-90 5" 5" 5"

G.P. Blue Mineral (BC) 60-90 5" 5" 5"

G.P. LDF (FD) 45-90 1-5/16" 5" 5"

Door Glazing ChartArchitectural Accessories DetailWood Door Technical Manual

Page 32: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

32

Wood FramesArchitectural Accessories DetailWood Door Technical Manual

Masonite Architecture Wood Doors offers a complete line of non-rated frames to compliment our fire-rated frames. All of our frames feature the same high quality craftsmanship as our stile and rail doors and will match them beautifully. We use the same veneer and finishing products on both doors and frames, regardless of fire-rating.

Over the last 35 years we have found flat jambs to be the most economical, environmentally responsible, and highest quality in appearance and construction. Flat jambs are a much more stable product than other types of jambs, and the veneered frame will be of superior face materials.

We produce flat jambs with the door stops constructed of solid lumber: long, loose, and unmitered to be applied in the field. This allows for a perfect fit when the door is hung and latched. The frames themselves will be a veneered construction with the exception of Paint Grade jambs which may be solid lumber. The 1/16” veneer used on the stiles and rails of our doors is the same 1/16” veneer we use on our frames. These frames can also be used for side-lights or transoms.

Standard jamb thickness is 13/16” and standard door stop size is 5/8” x 1-1/2” as shown in the standard construction drawing above. We can also produce custom frames in other dimensions with few restrictions for non-rated jambs.

Note on Rabbetted JambsMasonite Architecture Wood Doors also offers non-rated rabbetted jambs, in both single and double rabbet.However, for continuity of products as well as conservation of resources, We HIGHLY RECOM-MEND that a flat jamb with a wider door stop (as necessary) be used in lieu of solid lumber rabbetted jambs. Fire-Rated rabbetted jambs are not available.

Non-Rated Stain Grade Flat Jamb

Page 33: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016

33

20-Minute Fire-Rated Flat JambNeutral and Positive Pressure Categories A & B

Max. single frame size 4-0 x 9-0

Max. paired frame size 8-0 x 9-0

Wood species W. Pine or denser

Min. wall thickness 3.75”

Min. stop height .625”

Min. stop width 1.5”

Min. casing size 1.875” wide x .375”

Casing wood species Any

4-sided sidelight frames 3-0 x 9-0

4-sided transom frames 8-0 x 3-0

Borrowed sidelight frames 1-6 x 7-0

Borrowed transom frames N/A

Wall types Steel, wood stud, or masonry

20 Minute Stain Grade Flat Jamb

Wood FramesArchitectural Accessories DetailWood Door Technical Manual

Page 34: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

July, 2016

34

45 and 60 Minute Wood Frame SpecificationsNeutral and Positive Pressure Categories A & B

Neutral Pressure Positive Pressure

Max. single frame size 4-0 x 9-0 4-0 x 9-0

Max. paired frame size 8-0 x 9-0 8-0 x 9-0

Wood species Any Any

Min. wall thickness 4.625” 4.625”

Min. stop height .625” .625”

Min. stop width 1” (1.5” standard) 1.5”

Min. casing size 1.625” wide x .313” 1.625” wide x .313”

Wall types Steel stud, wood stud, or masonry

Steel stud, wood stud, or masonry

90 Minute Wood Frame SpecificationsNeutral and Positive Pressure Categories A & B

Neutral Pressure Positive Pressure

Max. single frame size 4-0 x 8-0 4-0 x 8-0

Max. paired frame size 8-0 x 8-0 Pending

Wood species Any Any

Min. wall thickness 4.875” 4.875”

Min. stop height .625” .625”

Min. stop width 1” (1.5” standard) 1.5”

Min. casing size 1.625” wide x .313” 1.625” wide x .313”

Wall types Steel stud, wood stud, or masonry

Steel stud, wood stud, or masonry

Wood FramesArchitectural Accessories DetailWood Door Technical Manual

Page 35: Architectural Accessories Details - graham …€¦ · Handing Chart Architectural Accessories Detail Wood Door Technical Manual Wood Doors Graham | Maiman May, 2017 Index Architectural

2

Handing ChartArchitectural Accessories DetailsWood Door Technical Manual

July, 2016 July, 2016

45, 60, and 90 Minute JambsNeutral and Positive Pressure Categories A & B

(Category B shown below)

Wood FramesArchitectural Accessories DetailWood Door Technical Manual

masonitearchitectural.com877.332.4484©2018 Masonite Architectural