Architect, Interior Design, Programmer, Planner, Building ...

13
PLAY YA P1 P2 P3 P3 P3 P3 P4 P4 P4 P4 P4 P5 P6 P6 P6 P7 P8 P8 P9 P9 P10 P11 P11 P12 P13 P14 HB HB 4"Ø 4"Ø 4"Ø 4"Ø 4"Ø 4"Ø 4"Ø 4"Ø VTR 4"Ø VTR 4"Ø VTR 3"Ø VTR 2"Ø AUTOVENT 4"Ø W.C.O. 2 WAY C.O. W/CONC COLLER @ GRADE 3"Ø 2" REVENT 2" @ WASHERBOX 2" @ WASHERBOX 3"Ø 4" REVENT 4"Ø 4"Ø 4"Ø 4"Ø 4"Ø VTR 2"Ø 2"Ø 4" REVENT 4" REVENT 4"Ø 2" VENT 2" VENT SHOWER DRAIN 2"Ø 2"Ø 2"Ø CONDENSATE DRAIN FROM AHU SEE HVAC PLAN 4"Ø FOR TANKLESS HEATER DRIP PAN 2"Ø CONDENSATE ABOVE - FROM AHU SEE HVAC PLAN 2"Ø WCO 3"Ø 4"Ø REVENT 4"Ø REVENT 2"Ø VENTS 2"Ø VENT SEE SITE UTILITIES PLAN FOR CONTINUATION P15 WCO FLOOR DRAIN P17 P17 P17 PLUMBING SPECIFICATIONS: 1. PROVIDE ALL PLUMBING ITEMS INDICATED ON THE DRAWINGS, DESCRIBED HEREIN OR OTHERWISE REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, INCLUDING: A. PLUMBING FIXTURES, FITTINGS AND EQUIPMENT. B. HOT AND COLD WATER SYSTEMS C. DRAIN WASTE AND VENT PIPING SYSTEMS. D. INDIRECT WASTE PIPING, INCLUDING ALL VALVES, TRAPS, PIPING AND ACCESSORIES FOR ALL EQUIPMENT. SIZE PER EQUIPMENT REQUIREMENTS. (ROOF DRAINAGE IS SHOWN ON ARCHITECTURAL DRAWINGS). 2. COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES, INCLUDING REQUIREMENTS OF THE 2015 (OR ADOPTED EDITION) INTERNATIONAL PLUMBING CODE. 3. THESE DRAWINGS AND SPECIFICATIONS REFLECT A STANDARD DESIGN WHICH MUST BE VERIFIED OR MODIFIED FOR EACH APPLICATION. AS A MINIMUM, VERIFY ALL EQUIPMENT LOADS AND REQUIREMENTS, PIPE AND SERVICE SIZES, SITE CONDITIONS, LOCAL ORDINANCES AND CODES ETC. 4. THE SUBMISSION OF A BID OR PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PALNS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND/OR LABOR DUE TO DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED UNLESS THESE DIFFICULTIES COULD NOT HAVE BEEN FORESEEN, EVEN THOUGH PROPER EXAMINATION HAD BEEN MADE. 5. COORDINATE WITH ALL TRADES AND VERIFY ALL EQUIPMENT ROUGH-IN ITEMS AND LOCATIONS WITH THE EQUIPMENT SUPPLIER OR CONTRACTOR. ALL RE-WORK AND CORRECTIONS REQUIRED DUE TO LACK OF COORDINATION SHALL BE THE CONTRACTOR'S RESPONSIBILITY, AND DONE AT NO COST TO THE OWNER. SEE FOUNDATION PLAN (IF APPLICABLE) FOR ROUGH IN DIMENSIONS OF PLUMBING SYSTEMS. 6. SUBMIT SIX COPIES OF SHOP DRAWINGS AND MATERIAL DATA SUBMITTALS TO THE CONTRACTOR OR ARCHITECT FOR APPROVAL BEFORE INSTALLATION. NO SUBSTITUTIONS SHALL BE ALLOWED WITHOUT PRIOR APPROVAL BY THE ARCHITECT. 7. SANITARY AND STORM DRAIN, WASTE AND VENTS SHALL BE STANDARD WEIGHT CAST IRON NO-HUB PER CISPI STANDARDS 301 AND 310 WITH STAINLESS STEEL ONE-PIECE NEOPRENE GASKETS. UNDER SLABL PIPING SHALL BE CAST IRON BELL AND SPIGOT PIPING WITH NEOPRENE GASKETS, OR A.B.I. "BEST" COUPLING. WHERE PERMITTED BY LOCAL AUTHORITY, APPROVED PVC OR ABS PLASTIC PIPE AND FITTINGS, PER ASTM D2661-89 OR D2665-89, MAY BE USED. 8. HOT AND COLD WATER AND INDIRECT WASTE PIPING: HARD-DRAWN COPPER TUBE, TYPE "L", PER ASTM 888-88A, MADE UP WITH WROUGHT OR FORGED COPPER SWEAT FITTINGS. PEX-TUBING IS PERMITTED TO BE USED. UNDER SLABS: TYPE "K" SOFT TEMPER COPPER TUBE WITHOUT JOINTS. SOLDER: LEAD-FREE, CANFIELD "100% WATERSAFE". NOTE: PEX TUBING IS PERMITED FOR ABOVE GROUND PIPING IN LIEU OF IN SLAB COPPER TUBING PIPING (VERIFY W/ARCHITECT BEFORE ASSUMING SUBSTITUTION) 9. VALVES: USE PIPE SIZE VALVES, AS SHOWN BELOW: A. GATE: MILWAUKEE 148 OR 149 B. CHECK: MILWAUKEE 509T OR 1509T C. PRESSURE AND TEMPERATURE RELIEF VALVES: WATTS TYPE 100XL. NOTE: PROVIDE TEFLON COATED BALL VALVES WHERE CONDITONS PERMIT. 10. FIXTURE TAILPIECES AND TRAPS FOR LAVATORIES AND SINKS SHALL BE BRASS TUBING, SEMI-CAST, OR CAST IRON; ALL BRASS TUBING SHALL BE 17 GAGE, CHROME PLATED. 11. ALL PIPE HANGERS, CLAMPS AND CHANNELS SHALL BE ADEQUATELY SIZED TO CARRY PIPE LOADS AND PREVENT SAGGING. 12. INSULATE ALL HOT WATER PIPING WITH OWENS CORNING TYPE ASJ/SSL-II HEAVY DENSITY FIBER GLASS WITH ALL SERVICE JACKET; 1/2" FOR RUNOUTS UP TO 12"; 1" FOR OTHER PIPING 2" OR LESS IN DIAMETER. INSULATION SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE STANDARDS. 13. ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLET AND PROPER INSTALLATION OF THE WORK OF THIS SECTION, SHALL BE NEW FIRST QUALITY OF THEIR RESPECTIVE KINDS, AND AS SELECTED BY THE CONTRACTOR SUBJECT OT ACCEPTANCE BY THE ARCHITECT. 14. LAY OUT THE PLUMBING SYSTEM IN CAREFUL COORDINATION WITH THE DRAWINGS, DETERMINING PROPER ELEVATIONS FOR ALL COMPONENTS OF THE SYSTEM AND USING ONLY THE MINIMUM NUMBER OF BENDS TO PRODUCE A SATIFFACTORILY FUNCTION SYSTEM. FOLLOW THE GENERAL LAYOUT SHOWN ON THE DRAWINGS IN ALL CASES EXCEPT WHERE OTHER WORK MAY INTERFERE. UNLESS SHOWN OTHERWISE, LAY OUT ALL PIPES TO FALL WITHIN PARTITION WALL, FLOOR, OR ROOF CAVITITS, AND TO NOT REQUIRE FURRING OTHER THAN AS SHOWN ON THE DRAWING. 15. DO NOT CUT INTO OR REDUCE THE SIZE OF ANY LOAD-CARRYING MEMBER WITHOUT THE PRIOR APPROVAL OF THE ARCHITECT. INSTALL ALL PIPES TO CLEAR ALL BEAMS AND OBSTRUCTIONS. 16. UNLESS SHOWN OTHERWISE, PROVIDE UNIFORM PITCH OF AT LEAST 1/4" PER FOOT FOR ALL HORIZONTAL DRAINAGE PIPING WITHIN THE BUILDING. 17. EXTEND ALL PLUMBING VENTS 16" MIN. ABOVE ROOF TO PARAPET HEIGHT. UTILIZE AUTOVENT WHERE PREMITTED BY PLUMBING CODE. 18. PROVIDE PRESSURE REDUCING VALVE IF WATER SERVICE PRESSURE EXCEEDS 80 P.S.I. PROVIDE PRESSURE BOOSTING SYSTEM IF PRESSURE IS BELOW 35 PSI. 19. PROVIDE SHUT-OFF GATE VALVES AND UNIONS AT ALL WATER CONNECTIONS TO EQUIPMENT 19. PROVIDE SHUT-OFF GATE VALVES AND UNIONS AT ALL WATER CONNECTIONS TO EQUIPMENT AND APPLIANCES. PROVIDE STOPS AND CHROME PLATED BRASS SUPPLIES AT ALL FIXTURES. 20. ISOLATE ALL DISSIMILAR MEATALS WITH "EPCO" DIELECTRIC UNIONS, EXCEPT FOR BRASS OR BRONZE VALVES WITH STEEL PIPE. 21. PROTECT THE POTABLE WATER SUPPLY AGAINST BACKFLOW AND SIPHONAGE FROM EQUIPMENT, FIXTURES, ETC., USING APPROVED BACKFLOW AND ANIT-SIPHON DEVICES. 22. THOROUGHLY CLEAN ALL PIPING AND EQUIPMENT, REMOVING ALL DIRT, RUST, OIL AND PLASTER. 23. TEST SANITARY, PROCESS, AND STORM DRAINAGE, PIPING BY PLUGGING ALL OPENINGS AND FILLING, WITH WATER TO A HEIGHT EQUAL TO A 10 FOOT HEAD. ALLOW TO STAND ONE HOUR OR LONGER AS REQUIRED. REPAIR LEAKING JOINTS AND THEN RE-TEST. 24. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN INSPECTED AND ACCEPTED BY THE LOCAL AUTHORITY AND/OR THE ARCHITECT. 25. TEST WATER LINES AT 100 P.S.I.G. RETAIN FOR 24 HOURS, REPAIR ALL LEAKS AND RETEST. 26. THE ENTIRE SYSTEM SHALL BE WARRANTED FOR A PERIOD OF ONE (1) YEAR BEGINNING WITH OWNER'S ACCEPTANCE OF THE WORK. ALL LABOR AND MATERIALS NECESSARY TO REPAIR OR REPALCE THE SYSTEM, OR PORTIONS THEREOF, DURING THAT TIME SHALL BE WARRANTED FOR A PERIOD OF (1) ONE YEARFOR THE REPAIR OR REPLACEMENT. 27. PLUMBING CONTRACTOR TO PROVIDE AND HOOK UP ALL CONDENSATION LINES. 28. PLUMBING CONTRACTOR TO PROVIDE AND HOOK UP ALL GAS LINES. 29. ALL FLOOR DRAINS AND HUB DRAINS TO HAVE TRAP PRIMERS. Grease Interceptor Sizing Data : 3 compartment sink size: 24"x24"x18" Cubic inch size per bowl: 3,468 cu. in. Total sink volume - max. discharge: 10,404 cu. In. (45.04 Gallons) Drainage Load - 75% of max. (Dishes displace 25% of the water in sink) 33.78 gallons. Actual Drainage Load in Gallons per min. = 16.89 gpm Flow thru rate - Total Gallons per Minutes: 16.9 gpm Drainage period of 3-Compartment Sink: 2 min. Passive conventional grease trap required: 20 gpm. Grease Interceptor provided: Trapzilla TZ-160 Flow Thru 35 gpm, 167lb. (serves 27 gallons) **calculation provided by Grease Trap Sizing Calculator by the mfg (Goslyn) as per International Plumbing Code Job No. Drawn By: Sewer - "A" Sheet No. Sheet Title: P1.01 PT Date: Matthew 7:7 CERTIFICATION AND SEAL I HEREBY CERTIFY THAT THIS PLAN AND SPECIFICATION WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF TEXAS AS SIGNIFIED BY MY HAND AND SEAL COPYRIGHT - PHILLIP B. TOWNSEND, R.A. Under the Copyright Act, 17 U.S.C. as amended December 1, 1990, also know as the "Architectural Works Protection Act of 1990" these documents are copyrighted and are subject to copywrite protection as an "Architectrual Work". The design, spatial forms, technical drawings, graphics, ideas, compositions, arrangement of items delineated in this set of plans and any related information are the property of Phillip B. Townsend, R.A. Unauthorized use of these plans, in whole or in part, can legally result in the cessation of such construction or building being seized and/or razed. Date of Copyright is as dated hearin. All rights reserved. Rom 6:3-6 Matthew 7:7 1 Cor. 15:1-4 Rom 1:16 I S A E T E T T A S T 6 F O 6 1 6 6 E X P R I L E I G S R P I H L T E W R N O T . D B E A E S D H C N T C Sanitary --- 940-642-3590 Phillip B. Townsend, R.A. Architect, Interior Design, Programmer, Planner, Building Code Consultant Wichita Falls, Texas 76310 4613 Misty Valley West Permitting or Construction NOT for Regulatory Approval Date of Issue for Review Only TAS and/or Permitting Approval Date of Issue for Regulatory, FOR Construction Scale: 1/4" = 1'-0" Floor Plan - Sanitary Sewer - Area "A" Lawton, OK 8th B Ave. The Comanche Nation A New Child Care Facility for Email: [email protected] Developer: Preschool 33'-2"x23'-7" 734 S.F. Safe Room 15'-4"x20'-9" 318 S.F. School Age 29'-1"x25'-5" 667 S.F. 16'-6"x14'-0" 230 S.F. Office 12'-6"x12'-0" 150 S.F. Office 12'-6"x12'-0" 150 S.F. Office 10'-3"x10'-4" 106 S.F. H.C. Toilet 10'-3"x6'-0" 59 S.F. Conference 14'-0"x17'-6" 246 S.F. Break Room 10'-9"x8'-7" 103 S.F. Laundry 10'-9"x8'-4" 104 S.F. Reception 18'-2"x14'-4" 260 S.F. 9'-7"x4'-10" 46 S.F. Kitchen 16'-0"x14'-2" 226 S.F. Pantry 14'-0"x9'-0" 126 S.F. Dining/Activity 14'-8"x21'-6" 314 S.F. Serving 16'-6"x7'-0" 116 S.F. Corridor 14'-9"x5'-0" 74 S.F. Corridor 27'-8"x4'-5" 122 S.F. Corridor 4'-2"x18'-9" 78 S.F. Toilet Jan. Corridor 5'-0"x73'-10" 369 S.F. Corridor Bathroom 5'-0"x18'-8" 118 S.F. Toilet 6'-2"x5'-4" 33 S.F. Toilet 6'-2"x5'-4" 33 S.F. Clos. 2'-2"x4'-0" 8 S.F. Clos. 1'-11"x5'-7" 11 S.F. Clos. 1'-11"x5'-7" 11 S.F. Cooler Freezer 8'-0"x6'-8" 53 S.F. 5'-7"x6'-8" 38 S.F. Vestibule 9'-8"x10'-7" 101 S.F. 2/22/2021 Feb. 2021 124 122 121A 110 111 112 113 107 106 105 101 117 116 118 119 120 108 109 115 129 101B 121B 124A 121B 107A 111A 112A 116 116A 100 105A 121 114 SEE FOUNDATION PLAN FOR DIMENSIONAL LAYOUT

Transcript of Architect, Interior Design, Programmer, Planner, Building ...

Page 1: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

P1

P2

P3P3

P3P3P4 P4

P4 P4

P4

P5

P6

P6

P6

P7

P8

P8

P9

P9

P10

P11P11

P12

P13

P14

HB

HB

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"ØVTR

4"ØVTR

4"ØVTR3"Ø

VTR2"Ø AUTOVENT

4"Ø W.C.O.

2 WAY C.O. W/CONCCOLLER @ GRADE

3"Ø

2" REVENT

2" @ WASHERBOX

2" @ WASHERBOX

3"Ø

4" REVENT

4"Ø 4"Ø 4"Ø 4"Ø4"ØVTR

2"Ø 2"Ø

4" REVENT

4" REVENT

4"Ø

2" VENT

2" VENT

SHOWERDRAIN

2"Ø

2"Ø

2"Ø CONDENSATE DRAINFROM AHU SEE HVAC PLAN

4"Ø

FOR TANKLESSHEATER DRIP PAN

2"Ø CONDENSATE ABOVE -FROM AHU SEE HVAC PLAN

2"Ø

WCO

3"Ø

4"Ø REVENT

4"Ø REVENT

2"Ø VENTS

2"Ø VENT

SEE SITE UTILITIES PLANFOR CONTINUATION

P15

WCO

FLOORDRAIN

P17

P17

P17

PLUMBING SPECIFICATIONS:1. PROVIDE ALL PLUMBING ITEMS INDICATED ON THE DRAWINGS, DESCRIBED HEREIN OROTHERWISE REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, INCLUDING:A. PLUMBING FIXTURES, FITTINGS AND EQUIPMENT.B. HOT AND COLD WATER SYSTEMSC. DRAIN WASTE AND VENT PIPING SYSTEMS.D. INDIRECT WASTE PIPING, INCLUDING ALL VALVES, TRAPS, PIPING AND ACCESSORIES FOR ALLEQUIPMENT. SIZE PER EQUIPMENT REQUIREMENTS.(ROOF DRAINAGE IS SHOWN ON ARCHITECTURAL DRAWINGS).

2. COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES, INCLUDINGREQUIREMENTS OF THE 2015 (OR ADOPTED EDITION) INTERNATIONAL PLUMBING CODE.

3. THESE DRAWINGS AND SPECIFICATIONS REFLECT A STANDARD DESIGN WHICH MUST BEVERIFIED OR MODIFIED FOR EACH APPLICATION. AS A MINIMUM, VERIFY ALL EQUIPMENT LOADSAND REQUIREMENTS, PIPE AND SERVICE SIZES, SITE CONDITIONS, LOCAL ORDINANCES ANDCODES ETC.

4. THE SUBMISSION OF A BID OR PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THECONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PALNS AND BUILDING SITE. CLAIMS MADESUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND/OR LABOR DUE TO DIFFICULTIESENCOUNTERED WILL NOT BE RECOGNIZED UNLESS THESE DIFFICULTIES COULD NOT HAVE BEENFORESEEN, EVEN THOUGH PROPER EXAMINATION HAD BEEN MADE.

5. COORDINATE WITH ALL TRADES AND VERIFY ALL EQUIPMENT ROUGH-IN ITEMS AND LOCATIONSWITH THE EQUIPMENT SUPPLIER OR CONTRACTOR. ALL RE-WORK AND CORRECTIONS REQUIREDDUE TO LACK OF COORDINATION SHALL BE THE CONTRACTOR'S RESPONSIBILITY, AND DONE ATNO COST TO THE OWNER. SEE FOUNDATION PLAN (IF APPLICABLE) FOR ROUGH IN DIMENSIONSOF PLUMBING SYSTEMS.

OF PLUMBING SYSTEMS.

6. SUBMIT SIX COPIES OF SHOP DRAWINGS AND MATERIAL DATA SUBMITTALS TO THECONTRACTOR OR ARCHITECT FOR APPROVAL BEFORE INSTALLATION. NO SUBSTITUTIONS SHALLBE ALLOWED WITHOUT PRIOR APPROVAL BY THE ARCHITECT.

7. SANITARY AND STORM DRAIN, WASTE AND VENTS SHALL BE STANDARD WEIGHT CAST IRONNO-HUB PER CISPI STANDARDS 301 AND 310 WITH STAINLESS STEEL ONE-PIECE NEOPRENEGASKETS. UNDER SLABL PIPING SHALL BE CAST IRON BELL AND SPIGOT PIPING WITH NEOPRENEGASKETS, OR A.B.I. "BEST" COUPLING. WHERE PERMITTED BY LOCAL AUTHORITY, APPROVED PVCOR ABS PLASTIC PIPE AND FITTINGS, PER ASTM D2661-89 OR D2665-89, MAY BE USED.

8. HOT AND COLD WATER AND INDIRECT WASTE PIPING:HARD-DRAWN COPPER TUBE, TYPE "L", PER ASTM 888-88A, MADE UP WITH WROUGHT OR FORGEDCOPPER SWEAT FITTINGS. PEX-TUBING IS PERMITTED TO BE USED.UNDER SLABS: TYPE "K" SOFT TEMPER COPPER TUBE WITHOUT JOINTS.SOLDER: LEAD-FREE, CANFIELD "100% WATERSAFE".

NOTE: PEX TUBING IS PERMITED FOR ABOVE GROUND PIPING IN LIEU OF IN SLAB COPPER TUBINGPIPING (VERIFY W/ARCHITECT BEFORE ASSUMING SUBSTITUTION)

9. VALVES: USE PIPE SIZE VALVES, AS SHOWN BELOW:A. GATE: MILWAUKEE 148 OR 149B. CHECK: MILWAUKEE 509T OR 1509TC. PRESSURE AND TEMPERATURE RELIEF VALVES: WATTS TYPE 100XL.

NOTE: PROVIDE TEFLON COATED BALL VALVES WHERE CONDITONS PERMIT.

10. FIXTURE TAILPIECES AND TRAPS FOR LAVATORIES AND SINKS SHALL BE BRASS TUBING,SEMI-CAST, OR CAST IRON; ALL BRASS TUBING SHALL BE 17 GAGE, CHROME PLATED.

11. ALL PIPE HANGERS, CLAMPS AND CHANNELS SHALL BE ADEQUATELY SIZED TO CARRY PIPELOADS AND PREVENT SAGGING.

12. INSULATE ALL HOT WATER PIPING WITH OWENS CORNING TYPE ASJ/SSL-II HEAVY DENSITYFIBER GLASS WITH ALL SERVICE JACKET; 1/2" FOR RUNOUTS UP TO 12"; 1" FOR OTHER PIPING 2"OR LESS IN DIAMETER. INSULATION SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25AND A SMOKE DENSITY NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH INTERNATIONALBUILDING CODE STANDARDS.

13. ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLET ANDPROPER INSTALLATION OF THE WORK OF THIS SECTION, SHALL BE NEW FIRST QUALITY OF THEIRRESPECTIVE KINDS, AND AS SELECTED BY THE CONTRACTOR SUBJECT OT ACCEPTANCE BY THEARCHITECT.

14. LAY OUT THE PLUMBING SYSTEM IN CAREFUL COORDINATION WITH THE DRAWINGS,DETERMINING PROPER ELEVATIONS FOR ALL COMPONENTS OF THE SYSTEM AND USING ONLYTHE MINIMUM NUMBER OF BENDS TO PRODUCE A SATIFFACTORILY FUNCTION SYSTEM. FOLLOWTHE GENERAL LAYOUT SHOWN ON THE DRAWINGS IN ALL CASES EXCEPT WHERE OTHER WORKMAY INTERFERE. UNLESS SHOWN OTHERWISE, LAY OUT ALL PIPES TO FALL WITHIN PARTITIONWALL, FLOOR, OR ROOF CAVITITS, AND TO NOT REQUIRE FURRING OTHER THAN AS SHOWN ONTHE DRAWING.

15. DO NOT CUT INTO OR REDUCE THE SIZE OF ANY LOAD-CARRYING MEMBER WITHOUT THEPRIOR APPROVAL OF THE ARCHITECT. INSTALL ALL PIPES TO CLEAR ALL BEAMS ANDOBSTRUCTIONS.

16. UNLESS SHOWN OTHERWISE, PROVIDE UNIFORM PITCH OF AT LEAST 1/4" PER FOOT FOR ALLHORIZONTAL DRAINAGE PIPING WITHIN THE BUILDING.

17. EXTEND ALL PLUMBING VENTS 16" MIN. ABOVE ROOF TO PARAPET HEIGHT. UTILIZE AUTOVENTWHERE PREMITTED BY PLUMBING CODE.

18. PROVIDE PRESSURE REDUCING VALVE IF WATER SERVICE PRESSURE EXCEEDS 80 P.S.I.PROVIDE PRESSURE BOOSTING SYSTEM IF PRESSURE IS BELOW 35 PSI.

19. PROVIDE SHUT-OFF GATE VALVES AND UNIONS AT ALL WATER CONNECTIONS TO EQUIPMENT

19. PROVIDE SHUT-OFF GATE VALVES AND UNIONS AT ALL WATER CONNECTIONS TO EQUIPMENTAND APPLIANCES. PROVIDE STOPS AND CHROME PLATED BRASS SUPPLIES AT ALL FIXTURES.

20. ISOLATE ALL DISSIMILAR MEATALS WITH "EPCO" DIELECTRIC UNIONS, EXCEPT FOR BRASS ORBRONZE VALVES WITH STEEL PIPE.

21. PROTECT THE POTABLE WATER SUPPLY AGAINST BACKFLOW AND SIPHONAGE FROMEQUIPMENT, FIXTURES, ETC., USING APPROVED BACKFLOW AND ANIT-SIPHON DEVICES.

22. THOROUGHLY CLEAN ALL PIPING AND EQUIPMENT, REMOVING ALL DIRT, RUST, OIL ANDPLASTER.

23. TEST SANITARY, PROCESS, AND STORM DRAINAGE, PIPING BY PLUGGING ALL OPENINGS ANDFILLING, WITH WATER TO A HEIGHT EQUAL TO A 10 FOOT HEAD. ALLOW TO STAND ONE HOUR ORLONGER AS REQUIRED. REPAIR LEAKING JOINTS AND THEN RE-TEST.

24. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN INSPECTED AND ACCEPTED BY THE LOCALAUTHORITY AND/OR THE ARCHITECT.

25. TEST WATER LINES AT 100 P.S.I.G. RETAIN FOR 24 HOURS, REPAIR ALL LEAKS AND RETEST.

26. THE ENTIRE SYSTEM SHALL BE WARRANTED FOR A PERIOD OF ONE (1) YEAR BEGINNING WITHOWNER'S ACCEPTANCE OF THE WORK. ALL LABOR AND MATERIALS NECESSARY TO REPAIR ORREPALCE THE SYSTEM, OR PORTIONS THEREOF, DURING THAT TIME SHALL BE WARRANTED FOR APERIOD OF (1) ONE YEARFOR THE REPAIR OR REPLACEMENT.

27. PLUMBING CONTRACTOR TO PROVIDE AND HOOK UP ALL CONDENSATION LINES.

28. PLUMBING CONTRACTOR TO PROVIDE AND HOOK UP ALL GAS LINES.

29. ALL FLOOR DRAINS AND HUB DRAINS TO HAVE TRAP PRIMERS.

Grease Interceptor Sizing Data:3 compartment sink size: 24"x24"x18"Cubic inch size per bowl: 3,468 cu. in.Total sink volume - max. discharge:10,404 cu. In. (45.04 Gallons)Drainage Load - 75% of max. (Dishes displace 25%of the water in sink) 33.78 gallons.Actual Drainage Load in Gallons per min. = 16.89 gpmFlow thru rate - Total Gallons per Minutes: 16.9 gpmDrainage period of 3-Compartment Sink: 2 min.Passive conventional grease trap required: 20 gpm.Grease Interceptor provided: Trapzilla TZ-160Flow Thru 35 gpm, 167lb. (serves 27 gallons)

**calculation provided by Grease Trap Sizing Calculator by themfg (Goslyn) as per International Plumbing Code

Job No.

Drawn By:

Sewer - "A"Sheet No.

Sheet Title:

P1.01

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Sanitary

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Sanitary Sewer - Area "A"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

Preschool33'-2"x23'-7"

734 S.F.Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

Office12'-6"x12'-0"

150 S.F. Office10'-3"x10'-4"

106 S.F.

H.C. Toilet10'-3"x6'-0"

59 S.F.

Conference14'-0"x17'-6"

246 S.F.

Break Room10'-9"x8'-7"

103 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.Pantry

14'-0"x9'-0"126 S.F.

Dining/Activity14'-8"x21'-6"

314 S.F.

Serving16'-6"x7'-0"

116 S.F.

Corridor14'-9"x5'-0"

74 S.F.

Corridor27'-8"x4'-5"

122 S.F.

Corridor4'-2"x18'-9"

78 S.F.

Toilet Jan.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Clos.2'-2"x4'-0"

8 S.F.

Clos.1'-11"x5'-7"

11 S.F.

Clos.1'-11"x5'-7"

11 S.F.

CoolerFreezer8'-0"x6'-8"

53 S.F.5'-7"x6'-8"

38 S.F.

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

124

122

121A

110

111

112

113

107

106

105

101

117116

118

119120

108

109

115

129

101B

121B

124A

121B

107A

111A 112A

116116A

100

105A

121114

SEE FOUNDATION PLAN FOR DIMENSIONAL LAYOUT

Page 2: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

TEMPERATURECHECK

P1

P3P3

P3P3

P3P3P3P3

P3P3

P4P4

P4

P4 P4

P4

P4

P4 P4

P4 P4

P7 P7

P7

P8 P8

P8

P9

P9

P9

P12

P13

HB

HB

HB

4"Ø

4"Ø

3"Ø

4" REVENT

4"Ø 4"Ø 4"Ø 4"Ø4"ØVTR

2"Ø 2"Ø

4" REVENT

4" REVENT

4"Ø

4"Ø

4"Ø

4"Ø REVENT

4" REVENT

2" VENT

2" VENT

2" VENT

3" VENT

3" VENT

4"Ø REVENT

3" VENT

3" VENT

3" VENT

3" VENT

4"Ø

WCO WCO

4" REVENT

3" VENT

2" VENT

2" VENT

SHOWERDRAIN

2" VENT

2"Ø

4"Ø

2"Ø CONDENSATE ABOVE -FROM AHU SEE HVAC PLAN

2"Ø

WCO

P17 P17

P17

P17

P17

LAVATORY KOHLER K2196-4-0 W, W/ DELTA 2529LF-HDF

INSTANT WATER HEATERS. S. BAR SINK

ELEC. WATER COOLER

TANK TOILET H.C.

MOP SINK

TYPE

JUVENILE TOILET

P1P2P3P4P5P6P7P8P9

MK

CAULK RIM TO COUNTER TOP

12"A.F.F., CAULK FIXTURE TO FLOOR

RIGHT HAND TANK - K4467-0-RA, CAULK FIXTURES TO FLOOR

REMARKS

W/BASKET & STRAINER ASSEMBLY

MOUNT NOZZLE @ 36" A.F.F. FOR H.C. - SEE ELEV., 1 SINGLE, 1 - HIGH/LOWWALL MOUNTED, GAS FIRED, FLUE THRU ROOFECCOTEMP EM-2.5

ELKAY

EZS8 - 8 GALLON ELKAY

MFG.

KOHLER

KOHLER

FIAT FL1W, W/DELTA 2121

MODEL NO.

K96059-0, K4467-0, 1955CT BEMIS

K4199-0, K4467-0, 1955CT BEMIS

PLUMBING FIXTURE SCHEDULE

FIXTURE NOTES:

TANK TOILET CAULK FIXTURES TO FLOORKOHLER K4198-0, K4467-0, 1955CT BEMIS

QTY

2110121334

FROST PROOF HOSE BIBB 17WOODFORD4

K115152, DELTA 2170-HDFRP12491

INSULATE ALL PLUMBING LINES - CAULK RIM TO COUNTER TOP

WALL HUNG LAVATORY INSULATE ALL PLUMBING LINES - SEE ELEVATIONSKOHLER K2032W, W/ DELTA 2529HDFP10WASHER BOX EASTMAN 60250P11BATHTUBP12SHOWERTHREE COMP. SINK

P13P14

12111

TANKLESS WATER HEATER1P15 RHEEM PERFORMANCE PLATINUM 11 GPM

KOHLER ELMBROOK 60 IN., LEFT DRAIN DELTA SINGLE HANDLE 5-SPRAY TUB W/ TEMPERING VALVE W/HAND HELD UNIT

GREASE INTERCEPTOR1P16 TRAPZILLA TZ-160 35 GAL. FLOW RATING, 167 POUNDS CAPACITY, 3" INLET/OUTLET

REGENCY 1.15 GPM WALL-MTD PRE-RINSE FAUCET, 8" CENTERS.EMPURA BPS-2454-3-18-FC W/2-18" DRAIN BD.DELTA #B112920, SINGLE HANDLE SHOWER W/TEMPERING VALVE W/HAND HELD UNITFINPAN PF007, 32" W x 36" DEEP

P17 6 FLOOR DRAIN

11. PROVIDE TWO TEFLON COATED BALL VALVES AT WATER HEATER

1. H.C. TOILET HANDLE LOCATION TO OPEN SIDE OF TOILET APPROACH 2. CONNECT LAVATORIES AND TANK TOILET W/STAINLESS STEEL BRADED FLEX LINES3. CAULK ALL FIXTURES TO ADJOINING SURFACES4. WALL STOPS TO BE CHROME PLATED5. P-TRAP ASSEMBLIES TO BE CHROME PLATED6. INSULATED ALL PLUMBING LINES UNDER SINKS AND LAVATORIES

8. COLOR AS SELECTED BY OWNER9. MAX BOWL DEPTH 6" FOR H.C. CLEARANCE10. FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE

7. ALL FAUCETS TO BE DELTA W/ WRIST BLADE HANDLES UNLESS OTHERWISE NOTED

FIXTURE NOTES:

CLOSED CELL INSULATIONDISTRIBUTION LINES W/ ARMAFLEX

INSULATE ALL EXPOSEDHOT AND COLD WATER

IF REQUESTED.

COLORS AND SUBSUTITUTIONS SHALL BE REVIEWED BY THE ARCHITECT

PROVIDE A WALL CLEANOUT AT THE END OF SANITARY SEWER RUN.

PLUMBING PLAN IS DIAGRAMATIC. LAYOUT AND SIZE OF ALL PLUMBINGLINES (WATER & SEWER) ARE LEFT TO SKILL OF THIS CONTRACTOR.

THIS CONTRACTOR SHALL PROVIDE THE CITY ANY ADDITIONAL INFORMATION

AND APPROVED BY OWNER.

REVENT STACKS TO ALLOW FOR MINIMUM ROOF PENITRATIONS OR AS SHOWN

GENERAL NOTES:

Job No.

Drawn By:

Sewer - "B"Sheet No.

Sheet Title:

P1.02

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Sanitary

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Area "B"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.

Infants18'-0"x19'-10"

402 S.F.

Toddlers18'-0"x19'-10"

542 S.F.

Preschool33'-2"x23'-7"

734 S.F.

Resource12'-0"x15'-4"

173 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

Conference14'-0"x17'-6"

246 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Office10'-0"x11'-2"

112 S.F. ISO/Sick10'-0"x11'-2"

88 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Corridor51'-1"x5'-0"

255 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

8 S.F.

Clos.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.Toilet

6'-2"x5'-4"33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

2'-0"x4'-1"

12 S.F.

Clos.6'-1"x2'-0"

8 S.F.

IT Clos.2'-8"x2'-11"

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

127

126

125

124

123

122

121A121B

105

102

103

101

128

129

101B

104

104A

130

103A

127A

126A

125A

124A

121B

127B

123A

100

105A

SEE FOUNDATION PLAN FOR DIMENSIONAL LAYOUT

Page 3: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

P1

P2

P3P3

P3P3P4 P4

P4 P4

P4

P5

P6

P6

P6

P7

P8

P8

P9

P9

P10

P11P11

P12

P13

P14

HB

HB3/4" C.W. 3/4" C.W.

1/2" C.W. DN.1/2" C.W. DN.

1/2" C.W.

3/4" C.W. DN

1" C.W.

3/4" H.W.

3/4" H.W.

1/2" C.W. DN.

1/2" H.W. DN.

1/2" C.W. DN.

1" C.W.

1/2" C.W. DN

1/2" C.W. DN

1/2" C.W. DN

1/2" C.W. DN

1/2" C.W. DN

1/2" C.W. UP

1/2" H.W. DN1/2" H.W. UP

1/2" H.W. DN

3/4" H.W.

1/2" H.W. DN

P15

3/4" H.W.UP

1/2" H.W.

1/2" C.W.1/2" C.W. DN

1/2" C.W. DN

P17

P17

P17

Job No.

Drawn By:

Distribution "A"Sheet No.

Sheet Title:

P1.03

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Water

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Water Distribution - Area "A"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

Preschool33'-2"x23'-7"

734 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

Office12'-6"x12'-0"

150 S.F.

Office10'-3"x10'-4"

106 S.F.

H.C. Toilet10'-3"x6'-0"

59 S.F.

Conference14'-0"x17'-6"

246 S.F.

Break Room10'-9"x8'-7"

103 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.

Pantry14'-0"x9'-0"

126 S.F.

Dining/Activity14'-8"x21'-6"

314 S.F.

Serving16'-6"x7'-0"

116 S.F.

Corridor14'-9"x5'-0"

74 S.F.

Corridor27'-8"x4'-5"

122 S.F.

Corridor4'-2"x18'-9"

78 S.F.

Toilet5'-0"x7'-3"

36 S.F.

Jan.4'-10"x7'-3"

33 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

7 S.F.Clos.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Clos.2'-2"x4'-0"

8 S.F.

Clos.1'-11"x5'-7"

11 S.F.

Clos.1'-11"x5'-7"

11 S.F.

CoolerFreezer8'-0"x6'-8"

53 S.F.5'-7"x6'-8"

38 S.F.

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

124122

121A

110

111112

113

107

106

105

101

117

116

118

119120

108

109

114

115

129

101B

121B121B

121B

124A

121B

107A

111A 112A

116116A

100

105A

121

Page 4: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

TEMPERATURECHECK

P1

P3P3

P3P3

P3P3P3P3

P3P3

P4P4

P4

P4 P4

P4

P4

P4 P4

P4 P4

P6

P7 P7

P7

P8 P8

P8

P9

P9

P9

P12

P13

HB

HB

HB

3/4" C.W. 3/4" C.W.

1/2" C.W. DN.1/2" C.W. DN.

1/2" C.W.

3/4" H.W.

3/4" H.W.

1/2" H.W. DN.

1/2" C.W. DN.

1/2" C.W. DN.

1/2" H.W. DN.

1/2" C.W. DN.

1/2" C.W. DN.

1" C.W. SUPPLY UP

1/2" C.W.

1/2" C.W. ABOVE 1/2" C.W. DN1/2" C.W.

1/2" C.W. ABOVE

1/2" C.W. DN1" C.W.

1" C.W.

1" C.W.

1/2" H.W.

FOR CONTINUATION SEESITE UTILITIES PLAN

1" C.W. SUPPLY

1/2" C.W. DN

1/2" C.W. DN. 1/2" C.W.

1/2" C.W. DN

P17 P17

P17

P17

P17

Job No.

Drawn By:

Demolition "B"Sheet No.

Sheet Title:

P1.04

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Water

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Water Distribution - Area "B"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.

Infants18'-0"x19'-10"

402 S.F.

Toddlers18'-0"x19'-10"

542 S.F.

Preschool33'-2"x23'-7"

734 S.F.

Resource12'-0"x15'-4"

173 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

Conference14'-0"x17'-6"

246 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Office10'-0"x11'-2"

112 S.F.

ISO/Sick10'-0"x11'-2"

88 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Corridor51'-1"x5'-0"

255 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

8 S.F.

Clos.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.Toilet

6'-2"x5'-4"33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

2'-0"x4'-1"

12 S.F.

Clos.6'-1"x2'-0"

8 S.F.

IT Clos.2'-8"x2'-11"

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

127

126

125

124

123

122

121A

121B

105

102 103

101

128

129

101B

104

104A

130

103A

127A

126A

125A

124A

121B

127B

123B

100

105A

Page 5: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

PLAY YARD

PORTICO

HB

HB

HB

HB

GAS METER1" GAS UP1" GAS SERVICEFROM UTILITY CO.

1"Ø GAS

3/4"ØFLEXGAS

GAS COCK

GASCOCK

3/4"ØFLEXGAS

1" YELLOW COATEDGAS LINE INVENTILATED ATTIC

AHU-1

AHU-2

1" YELLOW COATEDGAS LINE INVENTILATED ATTIC

NOTE:EACH AHU & TANKLESS W.H.SHALL BE PROVIDED WITHDOUBLE WALL FLUE THRUROOF (VERIFY SIZEREQUIRED)

3/4"ØFLEXGAS

GAS COCK

FOR CONTINUATION SEESITE UTILITIES PLAN

GAS COCKSEE NOTE

GAS VALVE FOR KITCHEN EQUIPMENTSHALL BE CONNECTED TO A SHUNTBREAKER THAT WILL SHUT OF GAS ANDPOWER TO EXHAUST /INTAKE FAN UPONACTIVATION OF ANSUL FIRE SUPPRESSIONSYSTEM

Job No.

Drawn By:

Distributon-"A"Sheet No.

Sheet Title:

P1.05

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Gas

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 3/16" = 1'-0"Floor Plan - Gas Distribution

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.

127

Infants18'-0"x19'-10"

402 S.F.

126Toddlers

18'-0"x19'-10"542 S.F.

125

Preschool33'-2"x23'-7"

734 S.F.

124

Resource12'-0"x15'-4"

173 S.F.

123

Safe Room15'-4"x20'-9"

318 S.F.

122

School Age29'-1"x25'-5"

667 S.F.

121A

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

110

Office12'-6"x12'-0"

150 S.F.

111

Office10'-3"x10'-4"

106 S.F.

112

H.C. Toilet10'-3"x6'-0"

59 S.F.

113

Conference14'-0"x17'-6"

246 S.F.

107

Break Room10'-9"x8'-7"

103 S.F.

106

Laundry10'-9"x8'-4"

104 S.F.

105

Office10'-0"x11'-2"

112 S.F.

102

ISO/Sick10'-0"x11'-2"

88 S.F.

103

Reception18'-2"x14'-4"

260 S.F.

101

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.

117Pantry

14'-0"x9'-0"126 S.F.

116

Dining/Activity14'-8"x21'-6"

314 S.F.

118

Serving16'-6"x7'-0"

116 S.F.

119

Corridor14'-9"x5'-0"

74 S.F.

120

Corridor27'-8"x4'-5"

122 S.F.

108

Corridor4'-2"x18'-9"

78 S.F.

109

Toilet5'-0"x7'-3"

36 S.F.

114

Jan.4'-10"x7'-3"

33 S.F.

115

Corridor51'-1"x5'-0"

255 S.F.

128

Corridor5'-0"x73'-10"

369 S.F.

129

Corridor

101B

Bathroom5'-0"x18'-8"

118 S.F.

104

8 S.F.

104A

Clos.

7 S.F.

130

Clos.

8 S.F.

103A

Clos.

Toilet6'-2"x5'-4"

33 S.F.

127A

Toilet6'-2"x5'-4"

33 S.F.

126A

Toilet6'-2"x5'-4"

33 S.F.

125A

Toilet6'-2"x5'-4"

33 S.F.

124A

Toilet6'-2"x5'-4"

33 S.F.

121BClos.

2'-2"x4'-0"8 S.F.

107A

Clos.1'-11"x5'-7"

11 S.F.

111A

Clos.1'-11"x5'-7"

11 S.F.

112A

2'-0"x4'-1"

12 S.F.

127B

Clos.6'-1"x2'-0"

8 S.F.

123A

IT Clos.2'-8"x2'-11"

CoolerFreezer8'-0"x6'-8"

53 S.F.

116A

5'-7"x6'-8"38 S.F.

116B

Vestibule9'-8"x10'-7"

101 S.F.

100

121

2/22/2021

Feb. 2021

Page 6: Architect, Interior Design, Programmer, Planner, Building ...

HB

HB

AHU-1

AHU-2

150 CFM

150 CFM

60 CFM 60 CFM

150 CFM

60 CFM

200 CFM

125 CFM

125 CFM

250 CFM 250 CFM

250 CFM

60 CFM

60 CFM

250 CFM

200 CFM

250 CFM

125 CFM

125 CFM

125 CFM

125 CFM

200 CFM

150 CFM

150 CFM

150 CFM

200 CFM

125 CFM

10"Ø

8"Ø

8"Ø

8"Ø

8"Ø

8"Ø

8"Ø

6"Ø

6"Ø6"Ø

7"Ø

7"Ø

10"Ø

7"Ø

7"Ø

7"Ø

6"Ø

6"Ø

10"Ø 10"Ø

10"Ø

10"Ø

125 CFM7"Ø

7"Ø

10"Ø

10"Ø

10"Ø

24"x

16"

20"x

14"

10"Ø

8"x1

2"10

"x12

"12

"x12

"16

"x12

"10

"x14

"12

"x14

"

8"x10"

DOWN - THRUCMU BLOCK(ABOVE 8'-0")

10"x

12"

8"x1

2"12

"x12

"14

"x14

"16

"x14

"

24"x16"

4,150 CFM

2,355 CFM

16"x

12"

24"x16"

10"x

10"

14"x

10"

16"x

14"

24"x24"

EF

EF

EF

EF

EF

70 CFM

70 CFM

24"x

16" R

ETU

RN

AIR

24"x24" RETURN AIR

24"x24" RETURN AIR

24"x

16" R

ETU

RN

AIR

24"x

16" R

ETU

RN

AIR

24"x24" RETURN AIR

70 CFM

70 CFM

CU-1 CU-2CU-COOLER/FREEZER

AS

AIR SCRUBBER

ASAIR SCRUBBER

FD

FD

FDFD

FD

FD

FD

T

7 DAY PROGRAMMABLE T-STAT TO AHU-1(VERIFY OPTIMAL LOCATION)

T

7 DAY PROGRAMMABLE T-STAT TO AHU-2(VERIFY OPTIMAL LOCATION)

CODES, RULES AND REGULATIONS:

THE INSTALLATION SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL AUTHORITIES HAVINGJURISDICTION AND THE RULES AND REGULATIONS OF THE SERVING UTILITY, AND ALSO THEREQUIREMENTS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS WHERE THE CONTRACTREQUIREMENTS ARE IN EXCESS OF APPLICABLE CODES, RULES AND REGULATIONS, THECONTRACT PROVISIONS SHALL GOVERN.

ARRANGE AND PAY FOR ALL INSPECTION WORK OF THIS SECTION REQUIRED BY LOCAL BUILDINGINSPECTOR, OBTAIN AND PAY FOR ALL PERMITS AND LICENSES, AND GIVE ALL NOTICES, PAY ALLFEES, COMPLY WITH ALL EXISTING LAWS, ORDINANCES, RULES AND REGULATIONS, BEARING ONTHE CONDUCT OF THE WORK AS SPECIFIED AND DRAWN.

HEATING, VENTILATING AND AIR CONDITIONING SPECIFICATIONS:INTENT:

THE INTENT OF THIS SPECIFICATION IS TO PROVIDE A STANDARD HVAC INSTALLATION FOR THEFACILITY WHICH IS FREE FROM HAZARD, EFFICENT, SERVICEABLE, CAPABLE OF MAINTAININGSPECIFIED MAXIMUM RELATIVE HUMIDITY AND TEMPERATURE AS SPECIFIED AND EASY TOMAINTAIN.

THE EQUIPMENT, SYSTEMS, AND CONTROLS SHALL BE DESIGNED AND INSTALLED IN SUCH AMANNER THAT WILL ENCOURAGE THE CONSERVATION OF ENERGY WITHOUT UNNECESSARYHARDSHIP OR INCONVENIENCE TO THE OWNER.

ALL WORK, MATERIALS AND EQUIPMENT SHALL BE GAURANTEED FOR ONE YEAR FOR THE DATEOF ACCEPTANCE BY OWNER OR TENANT, ANY APPEARING WITHIN THE ONE YEAR GAURANTEESHALL BE REMOVED AND REPLACED AT NO EXPENSE AND TO THE COMPLETE SATISFACTION OFTHE OWNER.

SCOPE OF WORK:

FURNISH A COMPLETE SYSTEM OF HEATING, AIR CONDITIONING AND ALL VENTILATING, THEDESIGN OF WHICH SHALL BE BASED UPON THE USE OF A CEILING SUPPLY AND RETURN AIRSYSTEM.

WORK INCLUDED UNDER THIS SECTION, WITHOUT LIMITING THE GENERALITY THEREOF, CONSISTSOF FURNISHING AND INSTALLING ALL MATERIALS, LABOR, EQUIPMENT, AND SERVICES NECESSARYFOR AND REASONABLY INCIDENTAL TO THE HEATING, VENTILATING AND AIR CONDITIONINGSYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN IN GENERAL, AS FOLLOWS:

1. AIR HANDLING UNIT, CONDENSING UNITS AND ASSOCIATED REFRIGERANT AND CONDENSATEPIPING. FURNACE AND COIL2. SHEET METAL WORK, INCLUDING DUCTWORK, DIFFUSERS AND REGISTERS,3. DUCT FURNACES GAS FIRED (OR AS OTHERWISE SPECIFIED).4. UNIT HEATERS, GAS FIRED (OR AS OTHERWISE SPECIFIED).

NEMA:

ELECTRICAL COMPONENTS USED IN THIS APPLICATION SHALL BE RATED IN ACCORDANCE WITHNEMA STANDARDS.

THE CONDUCT OF THE WORK AS SPECIFIED AND DRAWN.

INSPECTION AUTHORITY CERTIFICATE OF APPROVAL SHALL BE FURNISHED TO THE OWNERBEFORE FINAL ACCEPTANCE WILL BE GIVEN.

IF THE CONTRACTOR OBSERVES THAT THE DRAWINGS OR SPECIFICATIONS ARE AT VARIANCEWITH ANY LAWS, ORDINANCES, RULES AND REGULATIONS, HE SHALL PROMPTLY NOTIFY THEARCHITECT IN WRITING.

IF THE CONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO THE ABOVE, ANDWITHOUT NOTICE TO THE ARCHITECT, CONTRACTOR SHALL BEAR ALL EXPENSE REQUIRED TOMAKE THE WORK TO CONFORM IN AN ACCEPTABLE MANNER.

GUARANTEE:

ALL WORK, MATERIALS, AND EQUIPMENT SHALL BE GURANTEED FOR ONE YEAR EXCEPT,COMPRESSORS SHALL BE FOR 5 YEARS FROM OWNERS C.O. DATE. ANY DEFECTIVE ITEMSAPPEARING WITHIN THE GAURANTEE PERIOD SHALL BE REMOVED AND REPLACED AT NO EXPENSEAND TO THE COMPLETE SATISFACATION OF THE OWNER. OPERATIONS AND MAINTENANCEMANUALS WILL BE PROVIDE TO THE OWNER.

PROTECTION:

THIS CONTRACTOR SHLL BE RESPONSIBLE FOR THE PERFECT OPERATION OF THE ENTIRESYSTEM AND MUST MAKE GOOD AT HIS OWN EXPENSE ANY PART OF THE WORK WHICH MAY BESTOPPED UP, OR BECOME INOPERATIVE DUE TO LEAVING THE WORK UNPROTECTED DURINGCONSTRUCTION OF THE SYSTEM OR WHICH MAY BREAK OR FAIL IN ANY MANNER BY REASONS OFPOOR WORKMANSHIP OR DEFECTIVE MATERIALS FOR A PERIOD ONE YEAR FROM THE DATE OFFINAL ACCEPTANCE OF THE WORK.

1. AIR HANDLING UNIT, CONDENSING UNITS AND ASSOCIATED REFRIGERANT AND CONDENSATEPIPING. FURNACE AND COIL2. SHEET METAL WORK, INCLUDING DUCTWORK, DIFFUSERS AND REGISTERS,3. DUCT FURNACES GAS FIRED (OR AS OTHERWISE SPECIFIED).4. UNIT HEATERS, GAS FIRED (OR AS OTHERWISE SPECIFIED).5. EXHAUST FANS, INTAKE LOUVERS.6. INSULATION, PIPE AND DUCT.7. ENVIRONMENTAL CONTROL PANELS, ALL SYSTEMS SENSORS AND RELATED THERMOSTATS.8. TESTING AND BALANCING.9. PROVIDE ALL TEMPORARY HOOK REQUIRED TO TEST OUT EQUIPMENT.

THE ROOMS SHALL BE DESIGNED TO MAINTAIN 70 DEGREES F.D.B. INDOOR WINTER CONDITIONS.THE DESIGN AND INSTALLATION SHALL CONFORM WITH THE LATEST PUBLICATIONS ANDSTANDARDS AS RECOMMENDED BY ASHRAE UNLESS OTHERWISE NOTED IN THE FOLLOWINGPARAGRAPHS.

FIRE DAMPERS:ALL DUCT PENETRATING A FIRE PARTITION WILL HAVE RATED FIRE/SMOKE DAMPERS ASINDICATED BY "FD".

DUCTS:GALVANIZED SHEET METAL W/2" FIBERGLASS INSULATION MAX. 8' LENGTHS FOR FLEXIBLEDUCTWORK MIN. R-5. ALL DUCT SEAMS TO BE SEALED WITH UL181A OR 181B TAPES AND MASTICS,MECHANICAL FASTENERS AND SEALANTS MUST BE USED TO CONNECT DUCTS TO AIRDISTRIBUTION EQUIPMENT, BALANCING DEVICES PER IMC 603.15.

THERMOSTAT:HONEYWELL SINGLE STAGE W/NIGHT SET BACK AND LOCK BOX. T7300 OR EQUAL.

GRILLS AND DIFFUSERS:

SUPPLY: EQUAL TO "TITUS" MODEL TDCA AND "TITUS" 300 SERIES OR EQUAL. 2'x2' LAYINW/DAMPER, SIDE WALL DIFFUSERS AS SIZED ON PLANS.RETURN: EQUAL TO "TITUS" 50FF.

GUARANTEE:

ALL WORK, MATERIALS, AND EQUIPMENT SHALL BE GURANTEED FOR ONE YEAR EXCEPT,COMPRESSORS SHALL BE FOR 5 YEARS FROM OWNERS C.O. DATE. ANY DEFECTIVE ITEMSAPPEARING WITHIN THE GAURANTEE PERIOD SHALL BE REMOVED AND REPLACED AT NO EXPENSEAND TO THE COMPLETE SATISFACATION OF THE OWNER. OPERATIONS AND MAINTENANCEMANUALS WILL BE PROVIDE TO THE OWNER.

HEATING, VENTILATING AND AIR CONDITIONING DESIGN CONDITIONS:WALLS AND PARTITIONS WILL INCLUDE 3 1/2" BATT INSULATION, WHERE INDICATED ON PLANSCEILING WILL INCLUDE 6" BATT INSULATION OR SPRAY ON FOAM WHERE INDICATED ON PLANS.GLASS SHALL BE FIELD VERIFIED TO ASCERTAIN DESIGN CONDITIONS.OVERHANG OR SHADING AS PER BUILDIGN DETAILS.

OFFICE AREAS AND CLASSROOMS:SUMMER: 75 DEGREES, 50% RH INSIDE (APPROX), 100 DEGREES DB, 78 DEGREES WB OUTSIDEWINTER: 70 DEGREES DB INSIDE, 10 DEGREES WB OUTSIDE.

13

120,000 / 3/4" GAS / 80.00 Afue

SEERCOILMODELMFG.FLA 20

208/230/60/1P

4,00010T9580/67AHU-1 & 2 MARK

ENT. AIR (DB/WB)AMBIENT TEMP.NOM. TONSCFMHT. (BTU)/FUELVOLT/PHASE

A/C SCHEDULE

GREENHECKSOFFIT HOOD W/ DAMPER

-120V/1P

70 MIN.EF

MODELMANUFACTURERCURBFLAVOLT/PHASECFMMARK

EXHAUST FAN SCHEDULE

TRANE OR EQ.

CU 1 & 2

TRANE OR EQ.60208V/3P

13

10 T

NOTES:1. ECONOMIZER2. FRESH AIR SUPPLY MUST MEET ASHRAE 90-1 REQ.3. THERMOSTATS - 7 DAY PROGRAMMABLE, 48" A.F.F. VERIFY OPTIMAL LOCATION4. PROVIDE FURNACE WITH 6"Ø CONCENTRIC SUPPLY/EXHAUST VENT-THRU-ROOF5. FURNACE CABINET WIDTH = 22" MAX.6. INSTALL SMOKE DETECTOR IN EACH AHU RETURN AIR PLENUM7. INSTALL AIR SCRUBBERS IN EA. SUPPLY AIR PLENUM AS PER MFG. INSTRUCTIONS.

ECONOMIZER YES - 300 CFM EA.HAIL GUARD

4,000 S.F. MIN.120V

activTek INDUCT 5000ACTIVTEK OR EQ.AS

COVERAGE REQ.VOLTAGE

MODEL.MFG.MARK

AIR SCRUBBER

INSTALLATION PER. MFG. INSTRUCTIONS

ITEM NO. US40536

Job No.

Drawn By:

HVAC - "A"Sheet No.

Sheet Title:

M1.01

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Floor Plan

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - HVAC Area "A"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

Preschool33'-2"x23'-7"

734 S.F.Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

Office12'-6"x12'-0"

150 S.F.

Office10'-3"x10'-4"

106 S.F.

H.C. Toilet10'-3"x6'-0" 59 S.F.

Conference14'-0"x17'-6"

246 S.F.

Break Room10'-9"x8'-7"

103 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.

Pantry14'-0"x9'-0"

126 S.F.

Dining/Activity14'-8"x21'-6"

314 S.F.

Serving16'-6"x7'-0"

116 S.F.

Corridor14'-9"x5'-0"

74 S.F.

Corridor27'-8"x4'-5"

122 S.F.

Corridor4'-2"x18'-9"

78 S.F.

Toilet5'-0"x7'-3"36 S.F.

Jan.4'-10"x7'-3"

33 S.F.

Corridor5'-0"x73'-10"

369 S.F.Corridor

Bathroom5'-0"x18'-8"

118 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Clos.2'-2"x4'-0"

8 S.F.

Clos.1'-11"x5'-7"

11 S.F.

Clos.1'-11"x5'-7"

11 S.F.

CoolerFreezer8'-0"x6'-8"

53 S.F.5'-7"x6'-8"

38 S.F.

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

124122

121A

110

111112

113

107

106

105

101

117

116

118119

120

108

109

114 115

129101B

121B

121B

121B

124A

121B

107A

111A 112A

116116A

100105A

121

Page 7: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

HB

HB

HB

AHU-2

125 CFM

60 CFM

60 CFM

250 CFM

200 CFM

250 CFM

60 CFM 60 CFM

200 CFM

200 CFM

200 CFM

200 CFM

200 CFM

200 CFM

60 CFM

200 CFM

200 CFM

125 CFM

100 CFM

100 CFM

150 CFM

125 CFM125 CFM

125 CFM

40 CFM

7"Ø6"Ø

6"Ø

10"Ø

7"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

10"Ø

7"Ø

7"Ø

7"Ø

6"Ø6"Ø

6"Ø

8"x12"10"x12"8"x12" 10"x12" 12"x12" 14"x12" 17"x12"

24"x

12"

24"x

14"

24"x

16"

20"x

14"

8"x10"

8"x14" DUCTDOWN - THRUCMU BLOCK(ABOVE 8'-0")

24"x16"

4,150 CFM

8"x1

0"10

"x10

"14

"x10

"16

"x14

"

EF

EF

EFEF

EF

EF

EF

70 CFM

70 CFM

70 CFM70 CFM

70 CFM

8"Ø

7"Ø7"Ø

12"Ø

24"x16" RETURN AIR

24"x

16" R

ETU

RN

AIR

24"x

16" R

ETU

RN

AIR

24"x24" RETURN AIR

24"x

16" R

ETU

RN

AIR

ASAIR SCRUBBER

FD

FD

FD

FD

FD

T

7 DAY PROGRAMMABLE T-STAT TO AHU-2(VERIFY OPTIMAL LOCATION)

13

120,000 / 3/4" GAS / 80.00 Afue

SEERCOILMODELMFG.FLA 20

208/230/60/1P

4,00010T9580/67AHU-1 & 2 MARK

ENT. AIR (DB/WB)AMBIENT TEMP.NOM. TONSCFMHT. (BTU)/FUELVOLT/PHASE

A/C SCHEDULE

GREENHECKSOFFIT HOOD W/ DAMPER

-120V/1P

70 MIN.EF

MODELMANUFACTURERCURBFLAVOLT/PHASECFMMARK

EXHAUST FAN SCHEDULE

TRANE OR EQ.

CU 1 & 2

TRANE OR EQ.60208V/3P

13

10 T

NOTES:1. ECONOMIZER2. FRESH AIR SUPPLY MUST MEET ASHRAE 90-1 REQ.3. THERMOSTATS - 7 DAY PROGRAMMABLE, 48" A.F.F. VERIFY OPTIMAL LOCATION4. PROVIDE FURNACE WITH 6"Ø CONCENTRIC SUPPLY/EXHAUST VENT-THRU-ROOF5. FURNACE CABINET WIDTH = 22" MAX.6. INSTALL SMOKE DETECTOR IN EACH AHU RETURN AIR PLENUM7. INSTALL AIR SCRUBBERS IN EA. SUPPLY AIR PLENUM AS PER MFG. INSTRUCTIONS.

ECONOMIZER YES - 300 CFM EA.HAIL GUARD

4,000 S.F. MIN.120V

activTek INDUCT 5000ACTIVTEK OR EQ.AS

COVERAGE REQ.VOLTAGE

MODEL.MFG.MARK

AIR SCRUBBER

INSTALLATION PER. MFG. INSTRUCTIONS

ITEM NO. US40536

LEGENDSUPPLY AIR GRILLES (T-GRID AND SURFACE MOUNTED)TITUS TMSA 12"x12"

P

SUPPLY AIR GRILLES (T-GRID AND SURFACE MOUNTED)TITUS PAS-AA 24"x24" PERFORATED

SUPPLY AIR GRILLES (T-GRID AND SURFACE MOUNTED)TITUS TMSA 24"x24"

TITUS 50 F 24"x24"RETURN AIR GRILLES (T-GRID AND SURFACE MOUNTED)

7. INSTALL AIR SCRUBBERS IN EA. SUPPLY AIR PLENUM AS PER MFG. INSTRUCTIONS.

REQUIRED BY CEILING TYPELAY-IN FOR "T" BAR OR FLANGED AS

SUPPLY AIR GRILLE OR DIFFUSER

DIFFUSERDAMPER AT

S.S. SCREWCLAMP (TYP.)

TRUNK DUCT(SEE PLAN FOR SIZE)

DUCT JOINT SEALANTSEAL TAP WITH

METAL ELBOWROUND SHEET SMOOTH RADIUS

SEE PLAN FOR SIZE(MAXIMUM LENGTH 7'-0")FLEXIBLE DUCT

Job No.

Drawn By:

HVAC "B"Sheet No.

Sheet Title:

M1.02

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Floor Plan

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - HVAC - Area "B"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.

Infants18'-0"x19'-10"

402 S.F.

Toddlers18'-0"x19'-10"

542 S.F.

Preschool33'-2"x23'-7"

734 S.F.

Resource12'-0"x15'-4"

173 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

Conference14'-0"x17'-6"

246 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Office10'-0"x11'-2"

112 S.F.

ISO/Sick10'-0"x11'-2"

88 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Corridor51'-1"x5'-0"

255 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.8 S.F.

Clos.

7 S.F.Clos.

8 S.F.

Clos.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

2'-0"x4'-1"

12 S.F.

Clos.6'-1"x2'-0"

8 S.F.

IT Clos.2'-8"x2'-11"

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

127

126125

124

123

122

121A121B

105

102

103

101

128

129

101B

104104A

130

103A

127A

126A125A

124A

121B

127B

123B

100105A

Page 8: Architect, Interior Design, Programmer, Planner, Building ...

SEATING FOR 22

HB

$

PULL RING FOR ANSULFIRE SUPPRESSIONSYSTEM

FIRE EXTINGUISHERTYPE "K"

ANSUL FIRESUPPRESSIONSYSTEM

7' EXHAUST HOOD

10'-0" STAINLESS STEEL SPLASH

10' DISTANCE FORINTAKE AIR FAN

SEE ALSO GAS DISTRIBUTION PLANFOR SHUNT BREAKER AND GASVALVE WITH ANSUL FIRESUPRESSION SYSTEM DEPLOYMENT

ICEMAKER

S.S. TABLE

3 CO

MP. SIN

K

HANDWASH

SITE BUILT COOLER/FREEZERFOAM FILLED W/ 5/8" GYP. BDEACH SIDE WITH FRP PANELSALL WALLS AND CEILINGSEAL TO FLOOR EQUIP W/

5 SHELVES 5 SHELVES

32"

S.S.TABLE

RANGEEXHAUST HOOD

TRASH TRASH

FLOORDRAIN

32"

CFM/SF EXHAUST AIRFLOW RATE TABLE 403.1.1 = .7 CFM/S.F.227 S.F. x .7 = 160 CFM REQ. KITCHEN EXHAUST

HOOD EXAUST FAN @ 2,100 CFM (400 CFM PER L.F. x 7 HOOD = 2,100 CFM)

HOOD MAKE UP AIR REQUIRED: 2,2602,100 + 160 REQ. KITCHEN EXHAUST = 2,260 CFM MAKEUP AIR FAN

278 CFM FRESH AIR BREATHING ZONE + 160 EXHAUST =438 CFM FRESH AIR AT AC UNIT

EQUIPMENT SCHEDULED UNDER HOOD::

1 - GAS STOVE

403.3.1.1.1.1 BREATHING ZONE OUTDOOR AIRFLOW

Vbz = BREATHING ZONE

Az = ZONE FLOOR AREA:THE NET OCCUPIABLE FLOOR AREA OF THE SPACES IN THE ZONE.

ORDER PICKUP/DINING ROOM S.F. = 500

Pz = ZONE POPULATION:THE NUMBER OF PEOPLE IN THE SPACE OR SPACES IN THE ZONE

Pz = 25

Rp = PEOPLE OUTDOOR AIR FLOW RATE IN BREATHING ZONERp CFM/ PERSON

Rp = 7.5

Ra = AREA OUTDOOR AIRFLOW RATE IN BREATHING ZONE Ra CFM/FT2

Ra = .18

Equation 4-1Vbz = RpPz + RaAzVbz = (7.5 x 25) + (.18 x 500)Vbz = 188 + 90Vbz = 278 CFM REQUIRED BREATHING ZONE OUTSIDE AIRFLOW

227 S.F. KITCHEN AREA FOR EXHAUST

VOLUME DAMPERSUPPLY RISER WITH

STAINLESS STEEL

EXHAUST RISER

2.75"

INCANDESCENT LIGHT

24" MIN.

HANGING ANGLE

3" STANDOFF

GREASE FILTERSBAFFLE-TYPE

16" U.L. CLASSIFIED

4"

100W VAPORPROOF

PERFORATED PANEL

WITH REMOVABLE CUPGREASE DRAIN

BY TENANTEQUIPMENT

80" TYP.

33" MIN48" MAX

3"

16 GA. STEEL FLUE - EXTERIOR WELDED JOINTS WRAPPED W/1" MIN - MINERAL WOOL WITH WIRE MESHMAINTAIN 3/4" CLEAR ANULAR SPACE AT ROOF PENITRATIONOPTIONAL PRE-FAB UL LISTED FLUE ALL HOOD CONSTRUCTION AND INSTALLATION SHALL BE IN ACCORDANCE WITH CHAPTER 5 - IMC

FULL WIDTH OF HOODSTAINLESS STEEL SPLASH

18" MIN.

2 LAYERS OF 5/8" TYPE "X" GYP BD48" WIDE - ABOVE CEILING TO ROOF

36" MIN.

Job No.

Drawn By:

HoodSheet No.

Sheet Title:

M1.03

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Exhaust

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 3/8" = 1'-0"Exhaust Hood Plan

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

542 S.F.

33 S.F.

2/22/2021

Feb. 2021

See Life Safety Plan for Related Information

Page 9: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

HB

HB

AHU-1

AHU-2

42" GFI

42" GFI42" GFI

42" GFI

POWER FOR GASTANKLESS W.H.

42" GFI 42" GFI42" GFI

42" GFI

42" GFI

42" GFI

42" GFI

CP

CP

CP

CP

CP

CP

CP

CP

CP

CP42" GFI

CP42" GFI

GFI

GFI

32" GFI 32" GFI32" 220V 32" 220V

42" GFI

42" GFI

30"+/- GFI

30"+/- GFIGFI

GFI

CP

CP CP

CP

CPCP

CP

PLUGS IN CABINET

WP GFIIN BOX

FREEZER/COOLERCONDENSSER

CU-1 CU-2

CT CAN

GFI

GFI

DOOROPERATOR

DOOROPERATOR

ELEC.PANEL

WP GFIIN BOX

WP GFIIN BOX

LP9LP10

LP11

LP12

LP13

LP14

LP21

LP22LP23

LP24

LP25

LP26

LP27 LP28

LP29

LP30

LP31

LP32

LP32

LP33

LP35,37 LP34,36LP39

LP40

$

INTAKE FANVERIFY LOCATION

$HOODLIGHTSHOOD

FAN

HOODEXHAUSTFAN

FOR COND. UNITSSEE RISER DIAGRAM

GFISERVICE PLUGAND LED TASKLIGHTING FORAHU'S ABOVE

LP41

LP42

TAPCAN

FZR. FAN COILCOOLER. FANCOIL

250A FUSEDDISCONNECT TOPANEL "LP"

POWER TO AIRSCRUBBERCOORDINATE WITHHVAC

POWER TO AIRSCRUBBERCOORDINATE WITHHVAC

$

DOOR CHIME W/ VIDEO CAMERA(VERIFY & COORDINATE W/ONWER FOR TERMINAL LOCATION)

ELECTRICAL SYSTEM SPECIFICATIONS:1. THE EQUIPMENT ROUGH-INS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE, HOWEVER, INSOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT MAY VARYFROM WHAT IS SHOWN, THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONWITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESEDIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLYUPON THE CONTRACTOR.

2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2017 N.E.C. AND STATE AND LOCAL CODES ASTHEY APPLY.

3. SWITCHGEAR AND PANELS SHALL BE SQUARE "D" (OR APPROVED EQUAL). FURNISHED ANDINSTALLED BY CONTRACTOR.

4. ALL DISCONNECT SWITCHES SHALL BE RATED FOR GENERAL DUTY UNLESS OTHERWISENOTED. ALL EXTERIOR DISCO

5. STARTERS AND RELATED WIRING SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR.OVERLOAD UNITS SHALL BE INSTALLED AS PER NAME PLATE DATA ON EQUIPMENT, EXCEPT FORSUCH ITEMS AS ARE NORMALLY SUPPLIED WITH STARTERS INSTALLED (HVAC UNITS,DISHWASHERS ETC.) AT THEIR POINT OF MANUFACTURE, ALL STARTERS SHALL BE SUPPLIED ANDINSTALLED BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR WILL MOUNT ALLSUCH STARTERS, AS DIRECTED, FURNISHING SUPPORTING STRUCTURES WHERE NECESSARY.

6. ANY FEES ASSOCIATED WITH CONSTRUCTION AND INSPECTION SHALL BE BORNE BY THECONTRACTOR IN ORDER TO DELIVER TO THE OWNER A FINISHED BUILDING, READY FOROCCUPANCY AND 100% OPERATION.

7. TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR THE EQUIPMENT HEREININSTALLED SHALL BE GIVEN TO THE OWNER PRIOR TO ACCEPTANCE OF THE BUILDING FOROCCUPANCY.

OCCUPANCY.

8. ALL PANELBOARDS SHALL BE LABELED WITH RESPECT TO THEIR TITLE, WOLTAGE AND PHASE;(I.E. PANEL "A" 120/208/3P LABEL SHALL BE PHENOLIC PLASTIC WITH WHITE LETTERS AND BLACKBACKGROUND. LABELS SHALL BE PREMANENTLY FIXED TO THE EQUIPMENT.

9. PANELBOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFEXEDTO THE INSIDE DOOR.

10. ELEC. CONTRACTOR SHALL SUBMIT 6 COPIES OF SHOP DRAWINGS TO THE CONTRACTORAND/OR ARCHITECT FOR APPROVAL FOR ALL EQUIPMENT AND DEVICES INSTALLED, THERE WILLBE NO DRAW UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND REVIEWED BY ARCHITECT.

11. ANY DEVIATION FROM PLANS WITHOUT PRIOR APPROVAL OF THE ARCHITECT SHALL BE CAUSEFOR THE REJECTION OF MATERIALS AND/OR METHODS, AND ANY COST INCURRED TO CORRECTSUCH DEVIATION TO THE SATISFACTION OF THE ARCHITECT SHALL BE BORNE BY THECONTRACTOR.

12. ANY COST INCURRED DUE TO LACK OF COOPERATION AMONG THE TRADES SHALL BE BORNEBY THE CONTRACTOR.

13. THE SUBMISSION OF PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTORHAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TOTHE PROPOSAL FOR MATERIALS AND LABOR, BECAUSE OF DIFFICULITIES ENCOUNTERED, WILLNOT BE RECOGINIZED IF THEY COULD HAVE BEEN FORSEEN HAD PROPER EXAMINATION BEENMADE.

14. TRADE NAMES ARE GIVEN TO CLARIFY TYPE OF PODUCT AND QUALITY DESIRED.

15. CONTRACTORS SHALL VERIFY SERVICE VOLTAGE WITH UTILITY COMPANY AND REVISE ANDBALANCE PANELS AS REQUIRED.

16. ALL REMOTE EQUIPMENT IN ATTIC, ON ROOF OR GROUNDS SHALL HAVE A DISCONNECTSWITCH AT EACH PIECE OF EQUIPMENT. FURNISH FUSED DISCONNECTS AS REQUIRED BY N.E.C.

17. ALL EXTERIOR RECEPTACLES, JUNCTION BOXES AND EQUIPMENT SHALL BE WEATHERPROOF,GFI OR ON GFI BREAKER AS IDENTIFIED AND IN WATERPROOF BOX..

18. INSULATE ALL CONDUIT PASSING THROUGH WALLS OR CEILINGS OR OTHER SIMULARCONDITIONS

19. ALL EXTERIOR CONDUIT FOR WIRING SHOULD BE MINIMIZED BY ROUTING IN CEILING SPACE.NO EXTERIOR CONDUIT WILL BE ACCEPTED, U.O.N.

20. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUIT'SINSTALLATION, TO VERIFY WITH ALL OTHER TRADES CONCERENED THAT THE CIRCUIT WITHDEVICES AS DRAWN IS ADEQUATE IN SIZE AND MAKE-UP FOR THE MECHANICAL AND/OR KITCHENEQUIPMENT TO BE INSTALLED. IN ANY CONFLICT IN VOLTAGE, PHASE OR LOAD IS ENCOUNTEDREDWHICH WOULD ALTER THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ARCHITECT OROWNER IMMEDIATELY. FAILURE TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANYSUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON THE CONTRACTOR.

21. ALL ITEMS IN THE NOTES, SCHEDULES AND LEGEND MAY NOT NECESSARLY APPEAR ON THESEDRAWINGS.

22. MINMIUM WIRE SIZE SHAL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL BE 1/2" C. ALLWIRING SHALL BE RUN IN CONDUIT. MC CABELING IS PERMITTED.

23. WIRING SHOWN IN THE PANEL SCHEDULE IS THE MINIMUM REQUIRED. RUNS IN EXCESS OF90'-0" (ONE WAY) SHALL BE SIZED PER THE N.E.C. MAXIMUM 2% VOLTAGE DROP.

24. COORDINATE WITH LOCAL UTILITIES FOR THEIR REQUIREMENTS.

25. ANY ELECTRICAL OUTLETS WITHIN 6 FEET OF A SINK AND THROUGHOUT KITCHEN AREASSHALL BE GFI PROTECTED. PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS,UNLESS SPECIFICALLY NOTED ON THE DRAWINGS OR SCHEDULES. ALL GFI PLUGS SHALL BEVISIBLE AND ACCESSABLE.

26. PROVIDE A 120V RECEPTICLE WITHIN 25 FEET OF ALL HVAC EQUIPMENT IN THE ATTIC.

27. ALL ELECTRICAL TO BE RAN OVERHEAD UNLESS OTHERWISE NOTED.

28. ALL FIXTURES TO BE PROPERLY SECURED TO PREVENT MOVING ONCE IN PLACE.

29. ALL CONDUIT (REGID AND FLEXIBLE) SHALL BE PROPERLY SECURED AND NOT ALLOWED TO LIEON FLOOR, ETC.

2'x4' RECESSED FLOURSCENT, 3 BULB, T-8, 96W

1x4 SURFACED MTD. CLOSET LIGHT FIXTURE

EMERGENCY EGRESS LIGHT ON 90 MIN. BATTERY BACKUP

LIGHTING LEGEND

RECESSED CAN LIGHT FIXTURE

SURFACE MOUNTED EMERGENCY EGRESS LIGHT ON 90 MIN.BATTERY BACKUP

DOUBLE FACED EXIT LIGHT W/DIRECTIONAL ARROWS ON 90 MIN.BATTERY BACKUP

BATTERY OPERATED, SINGLE STATION SMOKE ALARM

EF EXHAUST FAN

SURFACED MTD. LED CANOPY LIGHT FIXTURE

SURFACE MOUNTED 100W LED WALL PACK ON PHOTOCELL

$

O.S.CEILING MOUNTED OCCUPANCY SENSOR SWITCH

LIGHT SWITCH

WALL MOUNTED OCCUPANCY SENSOR SWITCHO.S.

EXIT LIGHT W/ EMEG. EGRESS LIGHT ON 90 MIN. BATTERY BACKUPPROVIDE WITH DIRECTIONAL ARROWS AS SHOWN ON PLAN

Job No.

Drawn By:

Area "A"Sheet No.

Sheet Title:

E1.01

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Elec. Power

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan Electrical Power - Area "A"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

Preschool33'-2"x23'-7"

734 S.F.Safe Room15'-4"x20'-9"318 S.F.

School Age29'-1"x25'-5"

667 S.F.

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

Office12'-6"x12'-0"

150 S.F.

Office10'-3"x10'-4"

106 S.F.

H.C. Toilet10'-3"x6'-0"

59 S.F.

Conference14'-0"x17'-6"

246 S.F.

Break Room10'-9"x8'-7"

103 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.Pantry14'-0"x9'-0"

126 S.F.

Dining/Activity14'-8"x21'-6"

314 S.F.

Serving16'-6"x7'-0"

116 S.F.

Corridor14'-9"x5'-0"

74 S.F.

Corridor27'-8"x4'-5"

122 S.F.

Corridor4'-2"x18'-9"

78 S.F.

Toilet5'-0"x7'-3"36 S.F. Jan.

4'-10"x7'-3"33 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

8 S.F.Clos.

7 S.F.Clos. Toilet

6'-2"x5'-4"33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Clos.2'-2"x4'-0"

8 S.F.

Clos.1'-11"x5'-7"

11 S.F.

Clos.1'-11"x5'-7"

11 S.F.

CoolerFreezer8'-0"x6'-8"

53 S.F.5'-7"x6'-8"

38 S.F.

Vestibule9'-8"x10'-7"

101 S.F.

2/22/2021

Feb. 2021

124

122

121A

110

111112

113

107

106

105

101

117

116 118

119

120

108

109

114

115

129

101B

121B

121B

121B 124A

121B

107A

111A112A 116116A

100

105A

121

Page 10: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

TEMPERATURECHECK

P1

P3P3

P3P3

P3P3P3P3

P3P3

P4P4

P4

P4 P4

P4

P4

P4 P4

P4 P4

P6

P7 P7

P7

P8 P8

P8

P9

P9

P9

P12

P13

P15HB

HB

HB

Job No.

Drawn By:

Area - "B"Sheet No.

Sheet Title:

E1.02

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Elec. Power

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Area "B"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.

121B

Infants18'-0"x19'-10"

402 S.F.

121B

Toddlers18'-0"x19'-10"

542 S.F.

121B

Preschool33'-2"x23'-7"

734 S.F.

121B

Resource12'-0"x15'-4"

734 S.F.

121B

Safe Room15'-4"x20'-9"

318 S.F.

121B

School Age29'-1"x25'-5"

667 S.F.

121B

Conference14'-0"x17'-6"

246 S.F.

121B

Laundry10'-9"x8'-4"

104 S.F.

121B

Office10'-0"x11'-2"

112 S.F.

121BISO/Sick10'-0"x11'-2"

88 S.F.

121B

Reception18'-2"x14'-4"

260 S.F.

121B

9'-7"x4'-10"46 S.F.

Corridor51'-1"x5'-0"

255 S.F.

121B

Corridor5'-0"x73'-10"

369 S.F.

121BCorridor

121B

Bathroom5'-0"x18'-8"

118 S.F.

121B8 S.F.

121B

Clos.

7 S.F.

121B

Clos.

8 S.F.

121B

Clos.

Toilet6'-2"x5'-4"

33 S.F.

121B

Toilet6'-2"x5'-4"

33 S.F.

121B

Toilet6'-2"x5'-4"

33 S.F.

121B

Toilet6'-2"x5'-4"

33 S.F.

121B

Toilet6'-2"x5'-4"

33 S.F.

121B

2'-0"x4'-1"

12 S.F.

121B

Clos.6'-1"x2'-0"

8 S.F.

121B

IT Clos.2'-8"x2'-11"

Vestibule9'-8"x10'-7"

101 S.F.

121B

2/4/2021.

Feb. 2021

Page 11: Architect, Interior Design, Programmer, Planner, Building ...

PORTICO $

$

$

$

$

$

$$

$

$

$$

$$

$

$

$

$

$

$ $

O.S.

$ $

O.S.

$

O.S.

O.S.

O.S.

HB

HB

EF

EF

EF

EF

O.S.

LP1

LP2

O.S.

$

3

3

LP43

3

3

LP5

3 3

3

$3

LP6

3$ 3$

NIGHTLIGHT

3$

3

3

3

ELEC.PANEL

T

TIMER FOROUTSIDE LIGHTS

LP8ON PHOTOCELL

TOTIMER/PHOTOCELLLP7

EXTERIOR LIGHTS IN SOFFIT:TIMER SHALL ENERGIZE CIRCUIT (SET TO ON @4:30 P.M. AND OFF AT 7:30 A.M.) THEN LIGHTSARE ARE CONTROLLED BY PHOTOCELL -THIS TO INSURE THESE SOFFIT LIGHTS ONLYCOME ON BETWEEN THE HOURS STATEDDURING THE SEASONAL DAYLIGHTDIFFERENCES WITHOUT FURTHERADJUSTMENT

ONPHOTOCELL

LP34

1x4

LED

1x4

LED

1x4

LED

1x4

LED

EF

NIGHTLIGHT

NIGHTLIGHT

EXHAUST FANS ARE FURNISHEDAND INSTALLED BY MECHANICALCONTRACTOR - ELECTRICALCONTRACTOR SHALLCOORDINATE AND CONNECTPOWER TO EA. EXHAUST FAN

3

3

2'x4' RECESSED FLOURSCENT, 3 BULB, T-8, 96W

1x4 SURFACED MTD. CLOSET LIGHT FIXTURE

EMERGENCY EGRESS LIGHT ON 90 MIN. BATTERY BACKUP

LIGHTING LEGEND

RECESSED CAN LIGHT FIXTURE

SURFACE MOUNTED EMERGENCY EGRESS LIGHT ON 90 MIN.BATTERY BACKUP

DOUBLE FACED EXIT LIGHT W/DIRECTIONAL ARROWS ON 90 MIN.BATTERY BACKUP

BATTERY OPERATED, SINGLE STATION SMOKE ALARM

EF EXHAUST FAN

SURFACED MTD. LED CANOPY LIGHT FIXTURE

SURFACE MOUNTED 100W LED WALL PACK ON PHOTOCELL

$

O.S.CEILING MOUNTED OCCUPANCY SENSOR SWITCH

$ LIGHT SWITCH

$ WALL MOUNTED OCCUPANCY SENSOR SWITCHO.S.

EXIT LIGHT W/ EMEG. EGRESS LIGHT ON 90 MIN. BATTERY BACKUPPROVIDE WITH DIRECTIONAL ARROWS AS SHOWN ON PLAN

Scale: 1/4" = 1'-0"Floor Plan - Electrical Lighting - Area "A"

Preschool33'-2"x23'-7"

734 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

16'-6"x14'-0"230 S.F.

Office12'-6"x12'-0"

150 S.F.

Office12'-6"x12'-0"

150 S.F.Office

10'-3"x10'-4"106 S.F.

H.C. Toilet10'-3"x6'-0"

59 S.F.

Conference14'-0"x17'-6"

246 S.F.

Break Room10'-9"x8'-7"

103 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Kitchen16'-0"x14'-2"

226 S.F.

Pantry14'-0"x9'-0"

126 S.F.

Dining/Activity14'-8"x21'-6"

314 S.F.

Serving16'-6"x7'-0"

116 S.F.

Corridor14'-9"x5'-0"

74 S.F.

Corridor27'-8"x4'-5" 122 S.F.

Corridor4'-2"x18'-9"

78 S.F.

Toilet5'-0"x7'-3"36 S.F.

Jan.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Clos.2'-2"x4'-0"

8 S.F.

Clos.1'-11"x5'-7"

11 S.F.

Clos.1'-11"x5'-7"

11 S.F.

CoolerFreezer8'-0"x6'-8"

53 S.F.5'-7"x6'-8"

38 S.F.

Vestibule9'-8"x10'-7"

101 S.F.124

122

121A

110

111112

113

107

106

105

101

117

116

118

119

120

108

109

114

115

129

101B

121B

121B

121B 124A

121B

107A

111A 112A 116116A

100

105A

121

SEE LIFE SAFETY PLAN FOR RELATED INFORMATION

Page 12: Architect, Interior Design, Programmer, Planner, Building ...

PLAY YARD

PORTICO TEMPERATURECHECK

$

$ $

$

$$ $

$

$

$

$

$

$

$

$ $$

$ $

O.S.

O.S.

$ O.S. $ O.S.

$ O.S.

O.S.

HB

HB

HB

EF

EF

EF

LP3

O.S.

3

3

3

3

3

$3

3

33

LP43

3

3$ 3$

NIGHTLIGHT

3$

EFEF

1x4

LED

1x4

LED

1x4

LED

EF

EF

NIGHTLIGHT

NIGHTLIGHT

EXHAUST FANS ARE FURNISHEDAND INSTALLED BY MECHANICALCONTRACTOR - ELECTRICALCONTRACTOR SHALLCOORDINATE AND CONNECTPOWER TO EA. EXHAUST FAN

3 Job No.

Drawn By:

Area "B"Sheet No.

Sheet Title:

E1.04

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Elec. Lighting

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Scale: 1/4" = 1'-0"Floor Plan - Electrical Lighting - Area "B"

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2 & 3 Year Olds21'-2"x25'-3"

619 S.F.Infants

18'-0"x19'-10"402 S.F.

Toddlers18'-0"x19'-10"

542 S.F.

Preschool33'-2"x23'-7"

734 S.F.

Resource12'-0"x15'-4"

173 S.F.

Safe Room15'-4"x20'-9"

318 S.F.

School Age29'-1"x25'-5"

667 S.F.

Conference14'-0"x17'-6"

246 S.F.

Laundry10'-9"x8'-4"

104 S.F.

Office10'-0"x11'-2"

112 S.F. ISO/Sick10'-0"x11'-2"

88 S.F.

Reception18'-2"x14'-4"

260 S.F.

9'-7"x4'-10"46 S.F.

Corridor51'-1"x5'-0"

255 S.F.

Corridor5'-0"x73'-10"

369 S.F.

Corridor

Bathroom5'-0"x18'-8"

118 S.F.

8 S.F.Clos.

7 S.F.Clos.

8 S.F.

Clos.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

Toilet6'-2"x5'-4"

33 S.F.

2'-0"x4'-1"

12 S.F.

Clos.6'-1"x2'-0"

8 S.F.

IT Clos.2'-8"x2'-11"

Vestibule9'-8"x10'-7"101 S.F.

2/22/2021

Feb. 2021

127126

125

124

123

122

121A

121B

105

102 103

101

128

129

101B

104

104A

130

103A

127A

126A

125A

124A

121B

127B

123B

100

105A

SEE LIFE SAFETY PLAN FOR RELATED INFORMATION

Page 13: Architect, Interior Design, Programmer, Planner, Building ...

CONTACT WITH GROUND (GRADE BEAM REINFORCEMENTFOOTING BONDED TO REBAR THAT HAS DIRECT#4 x 20' BARE COPPER AT BOTTOM OF CONCRETE

SUPPORT BARS)

ENCLOSURESERVICE

BUSNEUTRAL

METALBUILDING

GROUNDING NOTES:

METAL CONDUIT (RGC

LESS SHALL BE AUGMENTED BY ONE RESISTANCE TO GROUND OF 25 OHMS OR PIPE, OR PLATE THAT DOES NOT HAVE A

C. RESISTANCE OF MADE ELECTRODES A

A. ALL CONDUCTORS SHALL BE MIN. #4 BARE COPPER (RUN IN METAL CONDUIT WHERE REQ'D)

SINGLE ELECTRODE CONSISTING OF A ROD,

B. GROUND AND NEUTRAL SHALL BE COPPER

PLATE BURIED 30" DEEPMIN. 4"x4"x1/4" STEEL#4 BARE COPPER TO

WHERE EXPOSED)

ELECTRICAL SYSTEM GROUND DETAIL

3/0 CONDUCTOR IN 3/4"

ADDITIONAL ELECTRODE

IF COPPERWATER PIPEUNDERGROUNDJUMPER

MESHCOPPER

WATER METER

250-53 AND 250-66 AS PER NEC 250-52,NOTE: BASE ALL GROUNDS

6'-0"MIN.

ALL WORK SHALL BE IN ACCORDANCEWITH 2017 NATIONAL ELECTRICALCODE INCLUDING LATEST LOCALAMENDMENTS ADOPTED BY THE CITYOF LAWTON

SIZE GROUNDING ELECTRODECONDUCTOR PER NEC TABLE250-90 AND RUN IN CONDUITWHERE EXPOSED

10'-0" LONG x 3/4"ØCOPPER WELD DRIVENGROUND RODS

TO METAL PIPESCONNECT PER NEC REQ.

SERVICE ENTRANCE EQUIPMENT(PANELBOARD, DISCONNECT, ETC.)

GROUNDBUS

PANEL "LP"NEW

GROUND TO:GROUND RODBUILDING STEELCOLD WATER PIPE

SEE GROUNDING DETAIL THIS SHEET

250A1P 3W120/240V 42 CKT'S

NEW 1-#2 GND

1-#2 GND

2 1/2" C, W/3#250 1 #2 G copper

CU-2

60A,1P, 3W,220V

FUSEDDISCONNECT

CU-1

60A,1P, 3W,220V

FUSEDDISCONNECT

FREEZER CU

60A,1P, 3W,220V

FUSEDDISCONNECT

CT CAN

20A,1P, 3W,120V

FREEZER/COOLERFAN COIL

300ATAP CAN120/2403 WIRE

CU-2

250A,1P, 3W,220V

FUSEDDISCONNECT

3-#6, 3/4"C

2-#12, 1/2"C

2 1/2" C, W/3#250 1 #2 G

Job No.

Drawn By:

Panel Sched.Sheet No.

Sheet Title:

E2.01

PT

Date:

Matthew 7:7

CERTIFICATION AND SEALI HEREBY CERTIFY THAT THIS PLAN ANDSPECIFICATION WAS PREPARED BY ME ORUNDER MY DIRECT SUPERVISION AND THAT IAM A DULY REGISTERED ARCHITECT UNDERTHE LAWS OF THE STATE OF TEXAS ASSIGNIFIED BY MY HAND AND SEAL

COPYRIGHT - PHILLIP B. TOWNSEND, R.A.Under the Copyright Act, 17 U.S.C. as amendedDecember 1, 1990, also know as the "ArchitecturalWorks Protection Act of 1990" these documentsare copyrighted and are subject to copywriteprotection as an "Architectrual Work". The design,spatial forms, technical drawings, graphics, ideas,compositions, arrangement of items delineated inthis set of plans and any related information arethe property of Phillip B. Townsend, R.A.Unauthorized use of these plans, in whole or inpart, can legally result in the cessation of suchconstruction or building being seized and/or razed.Date of Copyright is as dated hearin. All rightsreserved.

Rom 6:3-6Matthew 7:71 Cor. 15:1-4Rom 1:16

I

SA

ET

ET

TA

ST

6

FO61 6 6

EX

PRIL

EI

GS

R PIHL

TEWRNOT.

DB

E A

ES

D

HC

N

TC

Elec. Riser &

---

940-

642-

3590

Philli

p B.

Tow

nsen

d, R

.A.

Arch

itect

, Int

erio

r Des

ign,

Pro

gram

mer

, Pl

anne

r, Bu

ildin

g C

ode

Con

sulta

nt

Wic

hita

Fal

ls, T

exas

763

1046

13 M

isty

Val

ley

Wes

t

Permitting or ConstructionNOT for Regulatory Approval Date of Issue for Review Only

TAS and/or Permitting ApprovalDate of Issue for Regulatory,

FOR Construction

Law

ton,

OK

8th

& B

Ave.

Th

e C

oman

che

Nat

ion

A N

ew C

hild

Car

e Fa

cilit

yfo

r

Emai

l: pt

@w

f.net

Dev

elop

er:

2/22/2021

Feb. 2021

Electrical Riser Diagram

Electrical Grounding Detail

Electrical Panel Schedule