APPROX. LOCATION OF EXIST. 8 WE N OL A N E S A U G A T U C ...
Transcript of APPROX. LOCATION OF EXIST. 8 WE N OL A N E S A U G A T U C ...
![Page 1: APPROX. LOCATION OF EXIST. 8 WE N OL A N E S A U G A T U C ...](https://reader033.fdocuments.us/reader033/viewer/2022042122/6258324ed25e4a16f25f99ab/html5/thumbnails/1.jpg)
L=153.67R=250.00
L=37.75R=25.00
S26
°32'
36"W
287
.42'
N61°12'24"W 264.38'
REMOVEEXISTINGASPHALT
PAVEMENT
TRANSFORMER
100 YEARFLOOD LINE
L A N E
E N O
S
A
U
G
A
T U
C
K
A
V
E
N
U
E
C
O
N
N.
R
O
U
T
E
N
O
.
1
3 6
W
WATERMETER
12
14
10
10
16
CBGRT.=14.1INV.=10.9
CBGRT.=14.2
AE ZONE EL. = 13.0
15
15" RCP
S59°58'38"E 41.09'
2 5' P R I V A T E R O A D
N42°3
4'40"
E
2
73.0
0'
25.0'
15.0'
N66°51'34"E
74.80'
BUILDIN
G SETB
ACK LIN
E
30.0'
25.0
'
N61°12'24"W 166.93'
N40°34'2"W26.43'
25.0'
S26
°32'
36"W
273.
05'
N28°47'36"E40.14'
15.51'
25.58'
APPROX. LOCATION OFEXISTING 60 LF 4 X 4CONC. GALLERIES
W
W
W
W
W
W
APPROX. LOCATION OF EXIST. 8"WATER MAIN
84.5
5'
188.
45'16
14
18
30.0
'
EX. 28"MAPLE
EX. 36"OAK
EX. 24"MAPLE
EX. 24"MAPLE
EX. 36"MAPLE
EX. 42"SYCAMORE
EX. 30"SYCAMORE
EX. 36"MAPLE
EX. 42"SYCAMORE
N/FCAROLINE L. ALMONTE REV TR
3 ENO LANE
EXISTING
LAWN
TO
REMAIN
EXISTINGLAWN
TO REMAIN
EXISTINGLAWN
TO REMAIN
EXISTING PILLARSTO REMAIN
EXISTING PILLARSTO REMAIN
EX
ISTI
NG
HE
DG
ES
TO
RE
MA
IN
EX
ISTI
NG
HE
DG
ES
TO
RE
MA
IN
EX
ISTI
NG
HE
DG
ES
TO
RE
MA
IN
DTH-1
DTH-6
PROPOSEDSILT FENCE
PROPOSEDRAIN GARDEN #5
EXISTINGOFFICE BUILDING
(TO REMAIN)
LOAD SPACE
9
8
6
16
P-1
P-6
8
LOT 143,567 SF1.01 A.C.
TEMPORARYSTOCKPILE
AREA
4
5
18.0
'
9.0'
25.0
'
25.0'
18.0'
18.0'
9.0'
5.0'
18.0'
25.0'
8.0'
16.0
'
16
15.0016
DTH-2
P-2
PLANT WITH NEW ENGLAND CONSERVATION/WILDLIFESEED MIX SUPPLEMENTED WITH ADDITIONAL PLANTINGS
APPROVED BY CONSERVATION DEPARTMENT(SEE PLANTING NOTES)
INF-1STORMTECH SC-310 CHAMBERS
(10 ROWS, 12 UNITS/ROW)TOP OF STONE INV. = EL. 11.50
CB-1T.F. = 15.5INV. = 12.00
52 LF 15" CPP@ S=0.6%
F. L. = 11.50
EXISTING 1000 GAL.PUMP CHAMBER
TO REMAIN
EXISTING SEPTICTANK TO REMAIN
50.0'MIN.
25'MIN.
15.0'
13.0
'
12.3
'
13.0'
26 LF 15" CPP@ S=0.6%
16
16
16
CB-1T.F. = 15.6INV. = 11.83
OPEN SPACE24,412 SF0.56 A.C.
15'±
1AS
1AS
1SA
1SA
1SA
2PM
2PM
1PP
1SA
12TO
2PM
1PP
1PP
6JH
6JH
PA
VE
D
DRIVEWAY
LAW
N
TREE TOBE REMOVED
REVIS
ION D
ATE
ISSUE
C-1
1" = 20'
SCALE
7/14/2020
DATE
SM
DRAWN BY:
PR
CHECKED BY:
SCALE IN FEET
60200 40
20150-01
PROJECT No.
SIT
E IM
PR
OV
EM
EN
TS
F
OR
A
N E
XIS
TIN
G O
FF
IC
E B
UIL
DIN
G
TIT
LE:
PREPARED F
OR:
PROJECT L
OCATIO
N:
27
0 S
AU
GA
TU
CK
A
VE
NU
E
WE
ST
PO
RT
, C
T
27
0 S
AU
GA
TU
CK
A
VE
, L
LC
.
Civil E
ng
in
ee
rin
g S
ite
P
la
nn
in
g
En
viro
nm
en
ta
l S
cie
nce
&
E
ng
in
ee
rin
g
Stru
ctu
ra
l E
ng
in
ee
rin
g L
an
d S
urve
yin
g
Pe
rm
it C
oo
rd
in
atin
g &
M
an
ag
em
en
t
Co
nstru
ctio
n M
an
ag
em
en
t &
F
in
an
cin
g
51
8 R
ive
rsid
e A
ve
nu
e W
estp
ort, C
on
ne
cticu
t 0
68
80
2
03
-4
54
-2
11
0 in
fo
@la
nd
te
ch
co
nsu
lt.co
m
LOCATION MAP
1" = 1000'
NOT FOR CONSTRUCTIONFOR REVIEW AND APPROVAL
BY PUBLIC AGENCIES ONLY
E
W
O/H
T
LEGEND
20
20.1
(CB)
(MH)
(SSMH)
EXISTING SYMBOLS: PROPOSED SYMBOLS:
EXISTING LINETYPES: PROPOSED LINETYPES:
Iron Pin (Found)
Monument (Found)
Manhole
"C" Catch Basin
Utility Pole
Light Pole
Water Gate
Gas Valve
Gas Meter
Storm Drain Manhole
Catch Basin
Sanitary Sewer Manhole
Property Line
Underground
Piping (San.,Stm.)
U/G Elec. Line
Water Line
Overhead Utilities
U/G Tele. Line
Wood/Chain Link Fence
Stone Ret. Wall
Contour
Sanitary Sewer
Water Service
Silt Fence (GSF)
Retaining Wall
Spot Elevation
LP
GM
WG
GV
P-1
DTH-1
Perc Test Hole Location
& Number
Deep Test Hole Location
& Number
20.1 Spot Elevation
Electric Service
U/G Telephone Service
Wetland Limit
Contour (Major)
20
Primary Septic
Reserve Septic
Vegetative Buffer
Wetland Limit (Flagged)
WF#3 WF#4
100 Year Flood Line
Existing Well
Proposed Well
W
W
Floodway Boundary
Overhead Utilities
Watercourse Limit
Mean High Water
S
W
E
T
Wood/Chain Link Fence
Construction Fence
(YD) Storm Yard Drain
1
GENERAL NOTES1. LOT LINE & TOPOGRAPHIC INFORMATION FOR 270 SAUGATUCK
AVENUE TAKEN FROM ZONING MAP OF PROPERTY PREPARED BYDENNIS A. DEILUS LAND SURVEYORS DATED SEPTEMBER 14, 2016.
2. EXISTING SEPTIC SYSTEM ON LOT 1 TO BE MAINTAINED. EXISTINGSANITARY SEWER IN ENO LANE SATISFIES THE REQUIREMENT FOR ARESERVE SEPTIC AREA, i.e. B-100 CODE COMPLIANCE.
T:\A
CT
IVE
PR
OJE
CT
S\2
0150
-01
SW
EE
DLE
R -
270
SA
GA
TU
CK
AV
E. W
PT
\DR
AW
ING
S\C
ON
CE
PT
PLA
N 2
\270
SA
UG
AT
UC
K A
VE
.- S
ITE
PLA
N.D
WG
SPACES REQUIRED
OFFICE: 1 SP. / 250 S.F. OF GFA 6,500 / 250 = 26 SP.
26TOTAL SPACES
PARKING REQUIREMENTS 270 SAUGATUCK AVENUE
SPACES PROVIDED40
40
![Page 2: APPROX. LOCATION OF EXIST. 8 WE N OL A N E S A U G A T U C ...](https://reader033.fdocuments.us/reader033/viewer/2022042122/6258324ed25e4a16f25f99ab/html5/thumbnails/2.jpg)
REVIS
ION D
ATE
ISSUE
C-2
NTS
SCALE DATE
DRAWN BY: CHECKED BY:
PROJECT No.
TIT
LE:
PREPARED F
OR:
PROJECT L
OCATIO
N:
Civil &
S
tru
ctu
ra
l E
ng
in
ee
rs
En
viro
nm
en
ta
l S
cie
ntists
Pe
rm
it C
oo
rd
in
atio
n
Co
nstru
ctio
n M
an
ag
em
en
t
Co
nstru
ctio
n F
in
an
ce
51
8 R
ive
rsid
e A
ve
nu
e W
estp
ort, C
on
ne
cticu
t 0
68
80
2
03
-4
54
-2
11
0 in
fo
@la
nd
te
ch
co
nsu
lt.co
m
CONSTRUCTION ENTRANCE
PUBLIC R
OAD
50' MINIMUM
10' MIN
.
ROAD STABILIZATIONFILTER FABRIC
CT. D.O.T. 2" SIZECRUSHED GRAVEL
6" MIN.
(NTS)
NOTE:PLACE THE ANTI-TRACKING PAD ON THE SITE AT THE VEHICLEEXIT LOCATION SO THAT ALL VEHICLES LEAVING THE SITE MUSTPASS OVER THE PAD BEFORE ENTERING THE PUBLIC ROAD
SLOPE
GEOTEXTILE SILT FENCE (GSF)(NTS)
1-1/2" SQUAREHARDWOOD STAKEPLACED 10' O.C. MAX.
FABRIC FASTENEDTO STAKE
GROUND
BURY END OFFILTER FABRIC6"
100°
30"
MIN
.
18"
MIN
.
6"
ANGLE 10° UPSLOPE
NOT FOR CONSTRUCTIONFOR REVIEW AND APPROVAL
BY PUBLIC AGENCIES ONLY
T:\A
ctiv
e P
roje
cts\
2015
0-01
Sw
eedl
er -
270
Sag
atuc
k A
ve. W
PT
\Dra
win
gs\C
once
pt P
lan
2\27
0 S
auga
tuck
Ave
.- S
ite P
lan.
dwg
R=2"
FINAL GRADE
TOPSOIL
PARKING LOT PAVEMENT AND BIT. CURB TYPICAL CROSS SECTION(NTS)
1.5" CLASS 1BITUMINOUS CONCRETE
1.5" CLASS 2BITUMINOUS CONCRETE
CT DOT CLASS 3BITUMINOUS CONCRETE
9"
48°
1"
6"
2"
PROCESSED AGGREGATEBASE 8" THICK
B
TYPE "C" CATCH BASIN(NTS)
2 13/16"
8"
SECTION A-A
8" 8"
SECTION B-B
WHERE PRECAST CONCRETE UNIT IS USED FORSUMP, THE TOP OF THE UNIT SHALL BE ATLEAST 6" BELOW THE BOTTOM OF THE PIPEOUTLETTING FROM THE CATCH BASIN.
5'-4"8" 8"4'-0"
4'-4"8" 8"3'-0"
6"
VARIABLE
VARIABLE
6"
VARIABLE
VARIABLE
12" 2'-1 3/8" 8"
7 13/16"
8"
2 13/16"
DIMENSION AS PERSTORM DRAINAGE
STRUCTURES SCHEDULE
12" 2'-8 3/4"** 12"
2' 0"MINIMUM
7 5/8"7 5/8"
BRICK CLASS "A" CONCRETE,MASONRY CONCRETE UNITSWHERE BRICK OR MASONRYCONCRETE UNITS ARE USEDCORBELLING WILL BE PER-MITTED MAXIMUM CORBELLTO BE 3" NO PROJECTIONSHALL EXTEND INSIDE OFLIMITS NOTED BY * *
PLAN
A
B
A
4'-4"
5'4"
11 1/2"3 13/16"
2" 10 3/16" 10 3/16" 2"10"10"
5"
CLASS "A" CONCRETEPOURED IN PLACE ORPRECAST CONCRETE UNIT.
7 1/2"
1'-6 7/8" 1'-6 7/8"7 1/2"
3 5/8"
#4 BARS 4'-0" LONG
3 5/8"
CROSS SLOPING ASPER GRADING PLAN
NOTEWHEN CATCH BASIN IS SET INCONCRETE PAVEMENT THE 1/2" SLOPEON THE TOP SURFACE SHALL BECHANGED TO MATCH ADJOININGPAVEMENT 6" THICKNESS GRAVEL
OR 3/4" CRUSHED STONE
(NTS)
NYLOPLAST 18" FRP MANHOLE
18" PVC "DRAIN BASIN"AS MANUFACTURED BYNYLOPLAST OREQUIVALENT
PROVIDE 24" SUMPFOR CATCH BASIN6" SUMP FOR MANHOLE
HS-20 MANHOLE COVER
12" MIN.
FINISHEDGRADE
CL
1/4"/ FT 1/4"/ FT 1"/FT3
113
WIDTH VARIES AS SHOWN ON PLAN
4" TOPSOIL AND SEED(BOTH SIDES)
COMPACT SUBGRADE6" COMPACTED GRAVEL ORPROCESSED AGGREGATE BASE
2.5" BIT. CONC. CLASS 2
6' 3'6'
(NTS)DRIVEWAY TYPICAL SECTION
21°
ELEV. 16.0
ELEV. 15.0
51
(NTS)
RAIN GARDEN #5 SOIL LAYERING DETAIL 12" WASHED STONE
12" BIORETENTION SOIL MIX
GROUND
4'MIN.
GENERAL NOTES1. EXCAVATE RAIN GARDEN AREA TO PROPOSED INVERT DEPTHS AND SCARIFY EXISTING SOIL SURFACES,
TAKING CARE NOT TO COMPACT THE IN-SITU MATERIALS.2. PLACE SOIL IN ONE LIFT, DO NOT COMPACT.3. OVERFILL OF BIORETENTION SOIL IS REQUIRED TO ACCOMMODATE NATURAL SETTLEMENT TO PROPER
GRADE.4. BIORETENTION SOIL MIX TO BE 50% CONSTRUCTION SAND, 20-30% TOPSOIL WITH <5% CLAY, AND 20-30%
ORGANIC LEAF COMPOST
SC-310 TYPICAL CROSS SECTION(NTS)
16"
6"
12" MIN. TYP.
PAVEMENT
3/4 - 2-INCH WASHED,CRUSHED, ANGULAR STONE
34"6"MIN.
MIN.
18"MIN.
96"MAX.
ADS 601 GEOTEXTILEOR EQUAL
SC-310 END CAP
B
C
A
SC-310 CHAMBER
THE INSTALLED CHAMBER SYSTEM SHALL PROVIDETHE SAFETY FACTORS SPECIFIED IN THE AASHTO LRFD
BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOREARTH AND LIVE LOADS, WITH CONSIDERATION FOR
IMPACT AND MULTIPLE VEHICLE PRESENCES.GRANULAR WELL GRADED SOIL/AGGREGATEMIXTURES, <35% FINES. COMPACT IN 6 INLIFTS TO 95% PROCTOR DENSITY. SEE THETABLE OF ACCEPTABLE FILL MATERIALS .
CHAMBERS SHALL MEET ASTM F 2418-05 "STANDARDSPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATEDWALL STORMWATER COLLECTION CHAMBERS".
FOR UNPAVED INSTALLATION WHERE
RUTTING FROM VEHICLES MAY OCCUR,
INCREASE COVER TO 24 INCHES
EXCAVATION/FILL NOTES:
1. NO PROCESSING OF EARTH OF ANY KIND SHALL BE CONDUCTED ON THE SITE EXCEPT FOR MATERIALTHAT IS EXCAVATED DIRECTLY FROM THE PROJECT SITE FOR USE ON THE PROJECT SITE.
2. THERE SHALL BE NO SHARP DECLIVITIES, PITS OR DEPRESSIONS.
3. PROPER SURFACE DRAINAGE SHALL BE PROVIDED AND GROUNDWATER SHALL NOT BE POLLUTED.
4. AFTER EXCAVATION OR FILLING, THE PREMISES SHALL BE CLEARED OF DEBRIS AND TEMPORARYSTRUCTURES WITHIN THE TIME PROVIDED IN THE PERMIT.
5. FILL MATERIAL SHALL NOT INCLUDE ORGANIC (FOR EXAMPLE TREE STUMPS, LEAVES, BRUSH OROTHER MATERIALS THAT DECOMPOSE, ETC.) OR PETROLEUM BASED PRODUCTS OR MATERIALS.
6. LOT 1 - MAXIMUM CUT/FILL:
BASE LOT AREA (SQUARE FEET) X 50% OF THE ALLOWABLE TOTAL COVERAGE PERCENTAGE INRESPECTIVE ZONE X 10' DIVIDED BY 27 CUBIC FEET =
43,637 SF X (0.5 X 25%) X 10 / 27 = 2,020.2 CY
PROPOSED FILL: 0 CYPROPOSED CUT: 73 CY
7/14/2020
SM PR
20150-01
SIT
E IM
PR
OV
EM
EN
TS
F
OR
A
N E
XIS
TIN
G O
FF
IC
E B
UIL
DIN
G
27
0 S
AU
GA
TU
CK
A
VE
NU
E
WE
ST
PO
RT
, C
T
27
0 S
AU
GA
TU
CK
A
VE
, L
LC
.