APPLIED INSTRUMENT TECHNOLOGIES -...

8
AIT APPLIED INSTRUMENT TECHNOLOGIES Reliable on-line analyzers for optimizing your production process A United Technologies Company

Transcript of APPLIED INSTRUMENT TECHNOLOGIES -...

Page 1: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

AITA P P L I E D I N S T R U M E N T T E C H N O L O G I E S

Reliable on-line analyzers for optimizing your production process

A United Technologies Company

Page 2: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

A B O U T U S

A N A L E C T F T I R / F T - N I R ■ P I O N I R N I R ■ M G A M S ■ F X i P G C ■ C S 2 0 0 F I A

AITH A M I LT O N S U N D S T R A N D

A I T B r a n d s R e c o g n i z e d A r o u n d t h e W o r l d

■ Applied Instrument Technologies (AIT) is the process instrument business within Hamilton Sundstrand,

a United Technologies Company. Our products deliver important physical and chemical compositional

measurements to the process industry to reduce costs, improve quality and meet regulatory requirements.

AIT’s broad technology base includes FTIR, FT-NIR, NIR, Mass Spectrometry and Gas Chromatography,

which allows us to offer customers a choice of solutions. With process development and on-line systems,

AIT is able to provide both applications development support and real-time monitoring of batch and

continuous processes. ■ AIT serves the hydrocarbon processing, bio/pharmaceutical, chemical, steel,

natural gas, and other manufacturing industries. To ensure your success, our staff of dedicated engineers

and chemists participate in every phase of a project from application feasibility and system design to

installation, calibration, training and service support. ■ AIT designs, manufactures and markets process

analytical instruments worldwide from its headquarters in Pomona, California.

Page 3: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

ANALECT

ANALECT

Analect SoftwareFX90 & QC80

• Designed for reactionmonitoring & quality controlPC80 and CPSA

• Designed for processmonitoring, comprehensive analysis includingoutlier identification and capture, alarming functions, and detailed system diagnostics• Modbus® interface or optional OPC® allows bi-directional information exchange between the FTIR system and the process control computer

EVM

Provides multi-pointcontinuous air monitoring for toxicsand pollutants inhazardous areas

HSS/PCM 5000

On-line, real-time FTIRmonitoring of refineryand petrochemicalprocess streams in hazardous areas

RovIR

Transportable systemfor pilot-scale reac-tion monitoring inhazardous areas

ChemEye

Real-time dynamicmonitoring of reac-tion chemistries witheasy placementinside a fume hood

RefinIR with

Diamond 20

Automated samplingaccessory designedto be paired with theDiamond 20 lab analyzer

FOURIER TRANSFORM INFRARED ANALYZERS

AITH A M I LT O N S U N D S T R A N D

> Using a broad spectral region from the near-infrared to the mid-infrared,the ANALECT series of FTIR/FT-NIR analyzers measure physical and chemicalproperties of liquids, solids and gases. The process proven Analect Diamond 20interferometer provides superior performance for complex refinery applica-tions such as cat feed and crude oil, as well as applications for polymers,petrochemicals, chemicals, pharmaceuticals and general manufacturing.

> Satisfied customers include AGIP, Chinese Petroleum Corporation, DowChemical, DuPont, ExxonMobil, General Electric, Kodak, Monsanto and Shell.

PCM 1000

Utilizing fiber optics, this multi-channel FTNIRon-line system can beoperated in hazardous environments

DiamondMX

Utilizing fiber optics,this multi-channelFTNIR on-line analyzerwith rackmount designcan be operated ingeneral purpose areas

Page 4: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

Grating & Diode

Array Assembly

The optical bench, with holographic grating

Sample Systems

Turnkey sample conditioning systems

PIONIR

Fiber Optic Cable

The PIONIR series utilizes industrialgrade, environ-mentally stable,single fiber

Dual Beam Probe

The PIONIR has an innovative dual beam probe design

N E A R - I N F R A R E D A N A L Y Z E R S

PIONIR

PIONIR Software• Windows® based interfacecontrol of analyzer, samplesystem and communicationsSpectrum Quant+

• Full chemometric modelingcapability including PLS and PCRAVI™ Absolute Virtual Instrument• Provides seamless calibration transferabilitybetween PIONIRsCommunications

• Modbus interface or optional OPC allows bi-directional information exchange between the PIONIR and the process control computer

AITH A M I LT O N S U N D S T R A N D

PIONIR MVP

Multi-channel on-lineanalyzer with rack-mount design for thecontrol room

PIONIR 1024

Multi-channel on-lineanalyzer designedfor operation in hazardous areas

PIONIR MVP Lab

Support for processdevelopment, the MVP utilizes the same optical bench as the 1024

> The PIONIR series of NIR analyzers are designed for operation in processdevelopment as well as rugged, on-line environments utilizing patented and licensed BPAmoco technology. PIONIR systems provide real-time, multi-point analysis of refinery process streams such as gasoline and dieselfuel. Typical applications include RON, MON, distillation points, % aromaticsand cetane number.

> Satisfied customers include BP Amoco, BP Arco, ChevronTexaco, CITGO,ConocoPhillips, Rompetrol, Shell, Sibneft, Statoil and Sunoco.

Page 5: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

MGA

MGA SoftwarePrime,1600ES and Cypress Programs

• • Robust Windows based datastation witheasy-to-use software

• Optional validation assistance for 21 CFR Part 11 compliance• Communications options including Modbus,OPC, Ethernet, and analog protocols

MGA 1200EC

Fixed magnetic sector; less than 1 second response time,with mid-ppm to %level analysis of up to 10 components

MGA iSCAN

Double-focusing,magnetic scanninganalyzer measuringfrom low ppb to100%

MGA 1200 Users – Additional Upgrades

Prime software, system refurbishment or a complete rebuild into a 1200EC model available for MGA 1200s.

Area Classification

All models available for use in general purpose or hazardous area operation.

Sample Systems

Turnkey sampleconditioning systems and multi-point stream switching

MGA 1200 Upgrade –

Turbomolecular Pump

Replaces ion pump toincrease reliability and provide rapidpumpdown

MGAP R O C E S S M A S S S P E C T R O M E T E R S

Auto Calibration

AITH A M I LT O N S U N D S T R A N D

MGA 1600ES

Unique voltagescanning analyzer for analysis of up to16 components

> The MGA series of Multiple Gas Analyzers utilize proprietary magnetic sector technology to provide rapid, accurate and stable real-time monitoring of multicomponent gas streams. Typical process monitoring applications include ambient air, ammonia, ethylene oxide, fermentation, fuel cell analysis,high purity analysis, leak detection, blast furnace and coke oven top gas.

> Satisfied customers include BOC Gases, Delphi Automotive, Genzyme,Merck, Pfizer, Nippon Steel, U.S. Steel, Scientific Design, and UTC Fuel Cells.

Page 6: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

> The FXi process gas chromatograph continuously analyzes and reportscomponent concentrations and physical properties of liquid or gas processstreams. Typical applications include BTU, hydrocarbon dew point, H2S and total sulfur analysis in natural gas, speciation of hydrocarbon isomers,analysis of aromatic compounds, ambient air, high purity analysis at ppblevels and wastewater analysis.

> Satisfied customers include Shell, Goodyear, Huntsman, BASF, Xerox,Saudi Aramco, J&J Ethicon, Formosa Plastics and Malaysia LNG.

FXi

FXi SoftwareLAMS Local AnalyzerManagement System

• Windows based FXi software can be easily operated by a color

touchscreen graphical user interface• Seamless connectivity with the Invensys-Foxboro I/A Series system data highway as well as DCS and LAN systems throughModbus,® Ethernet, OPC® and analogprotocols

AIT

FXiP R O C E S S G A S C H R O M A T O G R A P H

H A M I LT O N S U N D S T R A N D

FXi Series5

Highly stable, fieldproven analyzer withversatile detectorand column options

Area Classification

Models available for use in general purpose or hazardous area operation.

Sample Systems

We can design andbuild single or multi-stream sampleconditioning systemsto optimize yourprocess

Foxboro 931C and

931D Upgrades

Field installation ofa custom door andfront panel touchscreen computerwith LAMS software

OEM Certified Spare

Parts

AIT provides spareparts to maintainFoxboro 931C and931D systems BTU Analysis

Page 7: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

> The CS200 system simultaneously measures H2S and CO2 for optimization of amine units in natural gas processing and crude oil refining.

> Sequential analysis of rich and lean amine streams.

> H2S measurements enable optimization of amine flow rates to reduce amine circulation costs, lower energy consumption, reduce amine degradation and reduce hydrocarbon carryover.

> CO2 measurement provides analysis to reduce corrosion and maximize CO2 slip.

> Compatible with all amines including MEA, DEA, MDEA, DFIPA, DGA and specially formulated amines.

CS 200

CS200 SoftwareRobust Windows NTSolid-State System

• • Windows based touchscreen menu displaysroutine results, system

setup, calibration and diagnostics• Dynamic graphical overlay screen displays • Automated diagnostic routines and alarmfunctions available• Remote system monitoring via networking port• Communications options including Modbus, Ethernet OPC and analog protocols

CS200A M I N E S T R E A M A N A L Y Z E R

CS 200

On-line system thatutilizes licensed andpatented BP Amocotechnology.

AITH A M I LT O N S U N D S T R A N D

Area Classification

Models available for use in general purpose or hazardous area operation.

Page 8: APPLIED INSTRUMENT TECHNOLOGIES - …dataintelek.com/home/Downloads/AIT/AIT_Analizers_Fambroc.Q5.pdf · Our products deliver important physical and chemical compositional ... component

> United Technologies Corporation is headquartered in Hartford, Connecticut and is the 49th largest company in the United States. Its stock is listed on the New York,London, Paris, Frankfurt, Brussels and Swiss Stock Exchanges under the symbol UTX.

> The principal businesses of the United Technologies Corporation are Carrier,Chubb, Hamilton Sundstrand, Otis, Pratt & Whitney, Sikorsky and UTC Power.

> Hamilton Sundstrand provides aerospace and industrial products and services for diversified industries worldwide. The industrial products include air compressors,metering devices, fluid handling equipment and gear drives from Falk, Milton Roy,Sullair and Sundyne.

> For more information about United Technologies Corporation please visit thecorporate web site at www.utc.com.

A B O U T U N I T E D T E C H N O L O G I E S

Contact our Marketing Dept. Applied Instrument Technologies 2771 North Garey Avenue, Pomona, CA 91767

t e l : ( 909 )593 -3581 x6100 f ax : ( 909 )392 -3207 e -ma i l : a i t@hs . u t c . c om www.h s -a i t . c om

International locations, see our website for your authorized representative.

A United Technologies Company

©20

03 H

amilt

on S

unds

trand

AIT.

ISO9001:2000

Certified Quality

�WorldwideLeader in Process Analytics

AIT

Analect® is a registered trademark of Hamilton Sundstrand Corp. PIONIR, MGA, FXi, CS 200, FX90, QC80, PC80, Cypress and Prime are trademarks of Hamilton Sundstrand Corp. AVI and Spectrum Quant+ are trademarks of PerkinElmer Corp. Windows® is a registered trademark of Microsoft Corp. Modbus® is a registered trademark of Modicon Corp. OPC® is a registered trademark of OPC Foundation.