Application Note MIL-STD-461 Phone 1-888-567-9596 www.synqor.com Doc.# 065-0000001 Rev. A 07/25/12 Page 1 To better serve our customer’s needs when de- signing with our power converters for compliance with MIL-STD-461, SynQor has performed test- ing with the following Hi-Rel, MCOTS, and InQor product(s). We can verify that our solutions meet or exceed the requirements of each subsection as listed below. Though testing was explicitly done with only 5V output product, results are guaranteed to extend to the other output voltages of each family. -461C Requirement Most Stringent Limit Tested -461D/E Requirement Most Stringent Limit Tested Conducted Emissions CE01 CE03 1 CE07 Class A5 (Submarine) Class A5 (Submarine) Class A1 (Aircraft) CE101 CE102 Submarine Basic Curve Conducted Susceptibility CS01 CS02 Class A5 (Submarine) Class A5 (Submarine) CS101 CS114 CS115 CS116 Curve #2 Curve #5 Basic Waveform I MAX = 10A CS06 Class A1/A5 (Aircraft/Sub) CS10 CS11 Class A5 (Submarine) Class A5 (Submarine) Radiated Emmisions RE01 RE02 2 Class A5 (Submarine) Class A5 (Submarine) RE101 RE102 2 Navy Submarine Radiated Susceptibility RS01 RS02 RS03 Class A5 (Submarine) Class A1/A5 (Aircraft/Sub) Class A4 (Surface Ship) RS101 RS103 Army Aircraft External Met by any MQ Filter Met by an MQ Filter having the Transient Suppresion Feature Hi-Rel - MQME-28-P (or -T) combined with MQFL-28-05S under a 120W resistive load Hi-Rel – MQHE-28-P combined with MQHL-28-05S under a 50W resistive load Hi-Rel – MQME-270-P combined with MQFL-270-05S under a 120W resistive load SynQor Products and MIL-STD-461 Compliance 1 For MQFL-270, converter and filter meet A1 limit of High Frequency Broadband Conducted Emissions and A5 limit of Narrowband Conducted Emissions 2 For MQFL-28, met with a metal screen shield covering the filter, converter, and resistive load Hi-Rel results are applicable to all output voltages of the MQFL-270, MQFL-28, MQFL-28E, MQFL- 28V, and MQFL-28VE families. MQHL-28 and MQHL-28E product tested only to limits listed for MIL- STD-461E and without radiated susceptibility testing.

Transcript of Application Note MIL-STD-461 SynQor Products and … compliance.pdfApplication Note MIL-STD-461...

Application NoteMIL-STD-461

Phone 1-888-567-9596 www.synqor.com Doc.# 065-0000001 Rev. A 07/25/12 Page 1

To better serve our customer’s needs when de-signing with our power converters for compliance with MIL-STD-461, SynQor has performed test-ing with the following Hi-Rel, MCOTS, and InQor product(s). We can verify that our solutions meet or exceed the requirements of each subsection as listed below. Though testing was explicitly done with only 5V output product, results are guaranteed to extend to the other output voltages of each family.

-461C Requirement

Most Stringent Limit Tested

-461D/E Requirement

Most Stringent Limit Tested

Conducted Emissions

CE01 CE031

CE07

Class A5 (Submarine)Class A5 (Submarine)

Class A1 (Aircraft)

CE101CE102

SubmarineBasic Curve

Conducted Susceptibility

CS01CS02

Class A5 (Submarine)Class A5 (Submarine) CS101

CS114CS115CS116

Curve #2Curve #5

Basic WaveformIMAX= 10A

CS06 Class A1/A5 (Aircraft/Sub)CS10CS11

Class A5 (Submarine)Class A5 (Submarine)

Radiated Emmisions

RE01 RE022

Class A5 (Submarine)Class A5 (Submarine)

RE101 RE1022

NavySubmarine

Radiated Susceptibility

RS01RS02RS03

Class A5 (Submarine)Class A1/A5 (Aircraft/Sub)Class A4 (Surface Ship)

RS101RS103

ArmyAircraft External

Met by any MQ Filter Met by an MQ Filter having the Transient Suppresion Feature

Hi-Rel - MQME-28-P (or -T) combined with MQFL-28-05S under a 120W resistive loadHi-Rel – MQHE-28-P combined with MQHL-28-05S under a 50W resistive load

Hi-Rel – MQME-270-P combined with MQFL-270-05S under a 120W resistive load

SynQor Products and MIL-STD-461 Compliance

1 For MQFL-270, converter and filter meet A1 limit of High Frequency Broadband Conducted Emissions and A5 limit of Narrowband Conducted Emissions2 For MQFL-28, met with a metal screen shield covering the filter, converter, and resistive load

Hi-Rel results are applicable to all output voltages of the MQFL-270, MQFL-28, MQFL-28E, MQFL-28V, and MQFL-28VE families. MQHL-28 and MQHL-28E product tested only to limits listed for MIL-STD-461E and without radiated susceptibility testing.

Phone 1-888-567-9596 www.synqor.com Doc.# 065-0000001 Rev. A 07/25/12 Page 2

MIL-STD-461Application Note

Application Note

-461D/E Requirement Most Stringent Limit Tested

Conducted Emissions

CE101CE102

SubmarineBasic Curve

Conducted Susceptibility

CS101CS114CS115CS116

Curve #2Curve #5

Basic WaveformIMAX= 10A

Radiated Emmisions

RE101 RE102*

NavyFixed Wing Internal, >25 meters Nose-to-Tail

The conducted emissions from various SynQor DC-DC converters in a given product series but with different output voltages would not vary significantly. All the converters in a product series use the same conversion and regulation stage on the input side of the converter, and the output voltage variations are achieved with different turns ratios in the isolation stage. Because of this architecture, the ripple and conducted emissions, both common-mode and differential-mode, can be assumed to be independent of the output voltage.

Mil-COTS and InQor

MCOTS and InQor results are applicable to all output voltages of the MCOTS-28, MCOTS-28V, and IQ24 input voltage ranges for the HP, HZ, QT and SM series only.

*Met with common-mode capacitors and a metal screen shield covering the filter, converter and resistive load

SynQor Products and MIL-STD-461 Compliance

Please contact the factory for details regarding test procedures and detailed results.

All 28VIN encased converters combined with an encased, quarter-brick passive filter. Applicable to Half-Brick Peta, Half-Brick Zeta, Quarter-Brick Tera and Sixteenth-Brick Mega families under full resistive load.