Application Manual
1800.888.5538 : www.FunctionalDevices.com
Relay and Current Sensor in OneDirectly start/stop load and current sensing all in one package (no external ring is needed.) Wire colors to “Load” and “60 Hz ac” differ depending on the model being used. Configurations are either YELLOW & ORANGE, BLUE & YELLOW, or ORANGE & ORANGE.
60 Hz ac
Load
Controller
Digital In
Digital Out
Transducer
StartStopRelay
SolidState
Switch
Internal 20 AmpRIBX24BFRIBX24SBFRIBX24BARIBX24SBA
Internal 10 AmpRIBXLCFRIBXLSFRIBXLCARIBXLSA
Internal 5 AmpRIBXLCEARIBXLSEA
Motor StarterAllows relay to control a motor starter while sensing current flowing to the motor.
Motor
Controller
Digital Out
Digital In
3-Phase
LineVoltage
MotorStarter
24 Vac
ExternalSensor Ring
Current Sensor Circuitry
Solid StateSwitch
Start/Stop Relay
Transducer
External Sensor RingRIBXLCRFRIBXLCRARIBXLCJFRIBXLCJARIBXLSRFRIBXLSRARIBXLSJFRIBXLSJA
Sensor only for 1.25 Amp to 150 Amp LoadUse sensor only devices without relay where start/stop is not required.
Motor
Controller
Digital Out
Digital In
3-Phase
LineVoltage
MotorStarter
ExternalSensor Ring
Current Sensor Circuitry
Solid StateSwitch
Transducer
External Sensor RingRIBXRARIBXRF
2 Functional Devices, Inc. : American Made. American Owned.
Panel Mounted Relay and Internal SensorStart/Stop Relays with Internal Current Sensors measure current flow through the relay contacts, no external ring is needed. Senses current as low as .50 Amp.
Panel
20 AmpMax Load
60 Hz ac
Current Sensor Circuitry
Solid StateSwitch
Transducer
Controller
Digital In
Digital Out
Start/Stop Relay
RIBMX
Internal 20 AmpRIBMX24BFRIBMX24SBFRIBMX24BARIBMX24SBA
Interlocking LoadsSome RIBX current sensor relays can be used to sense 1 or more loads to turn on another.
60 Hz ac
Current Sensor Circuitry
Solid StateSwitch
Transducer
24 VacSource
Dryer 1
Dryer 2
Start/Stop Relay
RIBX
LaundromatExhaust Fan
External Sensor
Internal 10 AmpRIBXLCRFRIBXLCRARIBXLCJFRIBXLCJARIBXLSRFRIBXLSRARIBXLSJFRIBXLSJA
Interlocking Loads (No Transformer)Self-powered Current Sensors of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1.
CurrentSensorStatus
Load 2
Load Wire
RIBX SERIESCurrent Sensor Only Low Voltage
(Class II)
Dry Contact InputRIB® Series
Local Power120, 240, 277 Vac
Current sensing maybe internal or external
Load 1
Dry Contact Input RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBM01ZNDCRIBM02ZNDCRIBM013PNDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)
Current Sensors RIBXKFRIBXKTFRIBXKARIBXKTARIBXGARIBXGFRIBXGTARIBXGTFRIBXGFLRIBXGTFL
RIBXFRIBXARIBXRFRIBXRARIBXJFRIBXJARIBMXFRIBMXARIBMXRFRIBMXRA
3800.888.5538 : www.FunctionalDevices.com
Damper Motor Control with True-HOAThe damper motor can be stopped in mid position for debugging. When auto/manual selector is in auto, relay controls the load. When in manual, use the manual switch to control the load.
Neutral
Open (120 Vac)
Close(120 Vac)
Auto ManLine (120 Vac)
ORANGE
YELLOW
BLUE
Open
N/CClosed
N/OClosed
DamperMotor
24 Vac From Controller
Wht/Blu
Wht/Yel
Wht/Blk(not used)
Auto / Manual Selector
Manual Switch
10 & 15 AmpRIBU1SCRIBH1SCRIBTU1SCRIBTH1SCRIBMU1SCRIBMH1SC
RIBU1S vs. RIBU1SCStock model RIBU1SC for relay control applications that require true-HOA on either N/O or N/C. No jumpers and no wrong orders.
24 Vac FromController
24 Vac FromController
Wht/Blu
Wht/Yel
Wht/Blu
Wht/Yel
RIBU1S
RIBU1SC
120 Vac
120 Vac
Orange
OrangeLOAD
LOAD
N/O or N/C, you choose
Yellow
Orange (N/O)
Blue (N/C)
RIBU1S has a lower costbut if N/C is desired onrelay, it must be speciedwhen ordering.
RIBU1SC is an alternativeto the RIBU1S that allowsone item to be ordered - noneed to specify N/O or N/C.
20 AmpRIB2401SBCRIB2402SBCRIBT2401SBCRIBT2402SBCRIBM2401SBCRIBM2402SBC
10 & 15 AmpRIBU1SCRIBH1SCRIBTU1SCRIBTH1SCRIBMU1SCRIBMH1SC
20 AmpRIB2401SBCRIB2402SBCRIBT2401SBCRIBT2402SBCRIBM2401SBCRIBM2402SBC
Digital In
Dry Contact Feedback Signal (when device is in manual position)
Analog Out
Analog Out
24 Vac/dc
RIBMNA1D0
Controller
Load
Manual Analog Override SwitchInitial installation or trouble shooting can be smoother and much less costly by adding the RIBMNA1D0. It allows you to manually control an analog output without accessing complicated algorithms in a controller. An indicator is provided for visual confirmation of percentage output. When you are finished, you can switch back to auto to put the controller back in control.
4 Functional Devices, Inc. : American Made. American Owned.
Limit Extra Transformers with Dry Contact Input RelaysEliminate the expense of extra transformer(s) and associated wiring.
Controller
120 Vac
Cont. Pwr.
Enclosure
DRY
CONTACTS
D.O.1
D.O.2
D.O.3
40VA
100VA
24 Vac
RIBU1C's
24 Vac
Controller
120 Vac
Cont. Pwr.
Enclosure
DRY
CONTACTS
D.O.1
D.O.2
D.O.3
40VA
24 Vac
Dry ContactInput RIB's
Before
After
Detect Water Levels with Dry Contact Input RelaysIf the water touches the wires, the relay will turn on (closes COMMON to N/O and opens COMMON to N/C.)Uses UL Approved low-voltage to sense water and activate relay.
ControlCircuit
Water Pan
Dry Contact Input Relay
Any typical non-corrosiveprobes may be used.
Relay Load
120-277 Vac Power
Enclosed RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)
Track RelaysRIBM01ZNDCRIBM02ZNDCRIBM013PNDC
Enclosed RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)
Track RelaysRIBM01ZNDCRIBM02ZNDCRIBM013PNDC
Monitoring Switch Position with a ControllerDigital In 1 and 2 of the controller can be used to monitor the position of the HOA switch. The controller can be programmed to log the status of the HOA and provide a warning if the switch is in an override position.
60 Hz ac
Controller
10-30Vac/dc
Common
120 Vac Not Used
Closed
Auto
Common
Load
RelayDigital Out
Common
Digital In 1
Digital In 2
Common
SwitchPole #2
SwitchPole #1
AutoCommon
Enclosed Relays10 AmpRIBU1SMRIBH1SM
Track Relays15 AmpRIBMU1SMRIBMH1SMRIBMNU1SMRIBMNH1SM
DI 1 DI 2 ResultOpen Open Overridden OffOpen Closed Auto
Closed Open Overridden OnClosed Closed Error Condition
5800.888.5538 : www.FunctionalDevices.com
High Voltage Optoisolated RelaysOptoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs.
Controller
Digital Out
(or Analog Out)
Relay
OptoInput
PowerSupply
60 Hz ac
Load
Opto RIB®
Enclosed RelaysRIBTE01BRIBTE02BRIBTE01SBRIBTE02SBRIBTE01PRIBTE02P
Low Voltage Optoisolated RelaysOptoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from low power digital or analog outputs.
Controller
Analog or Digital Out
24 Vac/dc
Relay
OptoInput
PowerSupply
60 Hz ac
Load
Opto RIB®
Enclosed RelaysRIBTELCRIBTELSRIBTE24BRIBTE24SBRIBTE24P
Polarized RelaysRelays are polarized to work in a supervised system and may be turned on and off by reversing polarity.For fire alarm systems, smoke control systems, etc.
Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P
Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P
Enclosed RelaysRIB12C-FARIB24C-FARIB12S-FARIB24S-FARIBT24B-FARIB24P-FA
Track RelaysRIBMN12C-FARIBMN24C-FARIBMN12S-FARIBMN24S-FA
Controller
End of Line
Resistor
Load
Signaling Circuit
RIB24C-FACoil
+ –
Load
+ –
RIB24C-FACoil
6 Functional Devices, Inc. : American Made. American Owned.
Condense Work Space and Wiring (Power Control)Power Control Centers allow you to save large amounts of time, space, and wiring throughout your panel.
Enclosure
ConduitPower Control Center is pre-wired
By using one of Functional Devices' Power ControlCenters you will greatly reduce installation time, aswell as save space in your enclosure.
Before After
There is a lot of extra wiring in this enclosurewhich not only takes up space but also increasesthe diculty and time associated with installation.
Sub-Panel
To remainderof panel
Switch, Breaker &Indicator Light
Enclosure
Conduit
Sub-PanelTo remainderof panel
Fuse
SwitchHNGHNG
Enclosed 4 AmpPSPT2RB4PSPW2RB4
Condense Work Space and Wiring (Power Supplies)The PSC, PSH, and PSB Series Power Supplies allow you to save large amounts of time, space, and wiring throughout your panel.
Enclosure
ConduitPower Supplies are pre-wired
By using one of Functional Devices' PowerSupplies you will greatly reduce installationtime, as well as save space in your enclosure.
Before After
There is a lot of extra wiring in this enclosurewhich not only takes up space but also increasesthe diculty and time associated with installation.
Sub-Panel
120Vac from10A Switch &CB to remainderof panel
Enclosure
Conduit
Sub-PanelTo remainderof panel
Fuse
SwitchHNGHNG
24Vac Power Supply
24Vac Switch/Breaker
24Vac 24VacIndicator
Main Power10A Switch/CB & Indicator Light
Power SuppliesAny models ending in “B10” in the PSC, PSH, or PSB Power Supply Series
Switch in a Box Enclosed ControlsPre-labeled 20 Amp switches are great for new installations or last minute corrections to controls jobs. Switch labels may be custom selected when ordering.
To A/CPower In
SummerWinter Heat
(Winter)Cool
(Summer)
2 Position
HandO
AutoContactor
3 Position
Coil
Controller
Digital Out
24 Vac
Contactor CoilHand
OAuto
24Vac Transformer
DO From Controller
2 PositionSIB04SSIB05S
3 PositionSIB02SSIBLS
Enclosed 10 AmpPSPT2RB10PSPW2RB10
7800.888.5538 : www.FunctionalDevices.com
Electronic Air CleanerModels RIBXGHF, RIBXGHTF, RIBXGHA, or RIBXGHTA can be used to control an electronic air cleaner based on whether or not the blower motor is turned on.
120Vac Source
Blower
Motor
LO
HI
C
Neutral
RIBXGHF, RIBXGHTF, RIBXGHA, or RIBXGHTA
When current drawn by Blower Motor exceeds RIBXGH threshold, SPST
contacts connect 120Vac source to
line input of Air Cleaner.
Electronic Air Cleaner
Humidifier ControlSolid and split core current sensors can be used along with a humidistat for control of a humidifier based on whether or not the blower motor is turned on.
24Vac
COM
Blower
Motor
LO
HI
C
Humidier
Humidistat
Enclosed MiniCurrent Sensor
Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTARIBXGFRIBXGTFRIBXGARIBXGTA
Occupancy Sensor on Open Protocol NetworkA LonMark® certified or a BACnet® compatible relay with a digital input can be used with an occupancy sensor in a room and turn on and off loads based on that status. This saves the cost of buying a LonMark® compatible or BACnet® compatible occupancy sensor by utilizing the digital input on our device.
LonMark® Certifed orBACnet® Compatible Relay
Class II Dry Contact Input
Network
24 Vac/dc
LineNeutral
LoadOrg Yel
Occupancy Sensor
LonMark® Certified Relays RIBTW2401B-LNRIBTW2402B-LNRIBTW2401SB-LNRIBTW2402SB-LN
BACnet® Compatible Relays RIBTW2401B-BCRIBTW2402B-BC
8 Functional Devices, Inc. : American Made. American Owned.
Loop-Powered RIBXK420 Series and RIBXG420 Series (High-Accuracy)
Enclosed Mini Current SensorsRIBXK420-20RIBXK420-50RIBXK420-100RIBXG420-20RIBXG420-50RIBXG420-100
DC Supply
- + RED +
Load Wire
BLACK -*Add 250 Ohms for 1-5 Vdc Analog In
Controller
- + 4-20 mA Analog In*1-5 Vdc Analog In
Mini Current Sensor
Load
MotorStarter
Line
Ope
n Co
ver
Hands and tools exposedto high voltage while
adjusting potentiometer ofcurrent sensor
( OLD WAY )
Danger!!!
Load
MotorStarter
Hands safely awayfrom high voltage because
SCAL adjusts itself
Clos
ed C
over
( NEW WAY )
Line
Screwdriver
Safe
NewRIBXGA-SCAL
OldManual Sensor
Self-Calibrating Current SensorsRIBXGA-SCALRIBXGTA-SCAL
Self-Calibrating Current SensorsThe self-calibrating current sensor begins its 30 second self calibration process the first time current is applied within the operating range. This procedure uses the user selected differential to set the trip threshold at a 15% or 25% level. Selection is completed prior to install using the appropriate DIP switch setting, keeping the installer’s hands away from possible shock hazard, as well as saving installation time.
250Ω
DC Supply
- +RED +
Load Wire
BLACK -*Add 250 Ohms for 1-5 Vdc Analog In
Mini Current Sensor
Enclosed Mini Current SensorsRIBXK420-20RIBXK420-50RIBXK420-100RIBXG420-20RIBXG420-50RIBXG420-100
Enclosed RelaysRIBTELCRIBTELSRIBTE24BRIBTE24SBRIBTE24P
Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P
Control Optoisolated Relay with 4-20mA LoopAdd 250Ω across Optoisolated Relay 5-25 Vdc control input. Relay turns on at approximately 10mA and off at 8mA.
9800.888.5538 : www.FunctionalDevices.com
Echelon® Thermistor-In ApplicationA thermistor is used to read the temperature of a room or area. That data is fed back to the LonWorks® system. When the temperature is out of range, the relay is commanded by the network, activating the exhaust fan, heater, or other device. A current sensor is used to feed back load status to the network. If there is a command and status mismatch, the network can issue an alarm to the operator’s console.
ThermistorFT-10 Network
24 Vac/dc
COM
Digital Input
Relay Output
Line
Exhaust Fan Heater
NeutralRIBX Series
Room or Area
or
LonMark® Compatible RelayEnclosed RelayRIBTW24SB-LNT2RIBTW24SB-LNT3
Track RelayRIBMW24SB-LNT2RIBMW24SB-LNT3
Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTA
FT-10 Network
24 Vac/dc
COM
LonMark® Certied Relay & Current Sensor
Exhaust Fan Heater
or
A/C Line Power
Relay
InternalCurrentStatus
Echelon® Relay / Current Sensor ApplicationSave time, money, and messy wiring. LonMark® certified relay contains an internal current sensor for load status. Relay control and load status are easily accessible from the FT-10 Network.
Enclosed ModelRIBTWX2401SB-LN RIBTWX2402SB-LN
Track ModelRIBMNWX2401SB-LN RIBMNWX2402SB-LN
RIBXGFRIBXGTFRIBXGARIBXGTARIBXGFLRIBXGTFL
10 Functional Devices, Inc. : American Made. American Owned.
Delay on Break (DOB) Time DelayLoad 2 stays on selected amount of time after load 1 goes off.
Yel
Blu
Wht/Yel
Wht/Brn
Yel
Blu
In this example, voltage can be any voltage from 120-277 Vac.
Neutral
RIBD2421CRIB®Select RIB® with coil input
appropriate to sense Load 1.
Load 2(Circulating Fan,
for example)
Load 1(Thermostat Controlled
Heater, for example)
Time Delay RelaysRIBD2421C
FT-10 Network
24 Vac/dc
COM
RIBMW24SB-LNAI or RIBTW24SB-LNAI
Digital Input
Relay Output
Line
HVAC Fan
NeutralRIBX Series
DierentialPressure
Transducer
Air Filter+5Vdc or+10Vdc
COM
Enclosed RelayRIBTW24SB-LNAI
Track RelayRIBMW24SB-LNAI
Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTA
Echelon® Analog-In ApplicationSimple and easy load control and status along with analog input provide everything needed to control and interface to your HVAC application. Save the expense of a controller for smaller remote jobs or complete larger jobs, as well.
RIBXGFRIBXGTFRIBXGARIBXGTARIBXGFLRIBXGTFL
Neutral
Fan
Local Power
Wire NutOrg
Yel
Blu
Wht/BlkWht/Blk
Neutral Hot
Wht/Red
Wht/Blu
DryContact
Wires
NormallyClosedSwitch
(Not provided)
RIBD01BDC – 120 Vac operation
RIBD02BDC – 208-277 Vac operation
Enclosed RelaysRIBD01BDCRIBD02BDC
Activate Load for Pre-Determined Time Using Dry Contact Input / Time Delay Relay and Normally Closed Switch
• Activate (open) switch until load comes on.• Release switch.• Load will be powered until time delay exprires.
AM578M 05.21.15