Page 1: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

Application Manual

Page 2: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

1800.888.5538 : www.FunctionalDevices.com

Relay and Current Sensor in OneDirectly start/stop load and current sensing all in one package (no external ring is needed.) Wire colors to “Load” and “60 Hz ac” differ depending on the model being used. Configurations are either YELLOW & ORANGE, BLUE & YELLOW, or ORANGE & ORANGE.

60 Hz ac

Load

Controller

Digital In

Digital Out

Transducer

StartStopRelay

SolidState

Switch

Internal 20 AmpRIBX24BFRIBX24SBFRIBX24BARIBX24SBA

Internal 10 AmpRIBXLCFRIBXLSFRIBXLCARIBXLSA

Internal 5 AmpRIBXLCEARIBXLSEA

Motor StarterAllows relay to control a motor starter while sensing current flowing to the motor.

Motor

Controller

Digital Out

Digital In

3-Phase

LineVoltage

MotorStarter

24 Vac

ExternalSensor Ring

Current Sensor Circuitry

Solid StateSwitch

Start/Stop Relay

Transducer

External Sensor RingRIBXLCRFRIBXLCRARIBXLCJFRIBXLCJARIBXLSRFRIBXLSRARIBXLSJFRIBXLSJA

Sensor only for 1.25 Amp to 150 Amp LoadUse sensor only devices without relay where start/stop is not required.

Motor

Controller

Digital Out

Digital In

3-Phase

LineVoltage

MotorStarter

ExternalSensor Ring

Current Sensor Circuitry

Solid StateSwitch

Transducer

External Sensor RingRIBXRARIBXRF

Page 3: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

2 Functional Devices, Inc. : American Made. American Owned.

Panel Mounted Relay and Internal SensorStart/Stop Relays with Internal Current Sensors measure current flow through the relay contacts, no external ring is needed. Senses current as low as .50 Amp.

Panel

20 AmpMax Load

60 Hz ac

Current Sensor Circuitry

Solid StateSwitch

Transducer

Controller

Digital In

Digital Out

Start/Stop Relay

RIBMX

Internal 20 AmpRIBMX24BFRIBMX24SBFRIBMX24BARIBMX24SBA

Interlocking LoadsSome RIBX current sensor relays can be used to sense 1 or more loads to turn on another.

60 Hz ac

Current Sensor Circuitry

Solid StateSwitch

Transducer

24 VacSource

Dryer 1

Dryer 2

Start/Stop Relay

RIBX

LaundromatExhaust Fan

External Sensor

Internal 10 AmpRIBXLCRFRIBXLCRARIBXLCJFRIBXLCJARIBXLSRFRIBXLSRARIBXLSJFRIBXLSJA

Interlocking Loads (No Transformer)Self-powered Current Sensors of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1.

CurrentSensorStatus

Load 2

Load Wire

RIBX SERIESCurrent Sensor Only Low Voltage

(Class II)

Dry Contact InputRIB® Series

Local Power120, 240, 277 Vac

Current sensing maybe internal or external

Load 1

Dry Contact Input RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBM01ZNDCRIBM02ZNDCRIBM013PNDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)

Current Sensors RIBXKFRIBXKTFRIBXKARIBXKTARIBXGARIBXGFRIBXGTARIBXGTFRIBXGFLRIBXGTFL

RIBXFRIBXARIBXRFRIBXRARIBXJFRIBXJARIBMXFRIBMXARIBMXRFRIBMXRA

Page 4: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

3800.888.5538 : www.FunctionalDevices.com

Damper Motor Control with True-HOAThe damper motor can be stopped in mid position for debugging. When auto/manual selector is in auto, relay controls the load. When in manual, use the manual switch to control the load.

Neutral

Open (120 Vac)

Close(120 Vac)

Auto ManLine (120 Vac)

ORANGE

YELLOW

BLUE

Open

N/CClosed

N/OClosed

DamperMotor

24 Vac From Controller

Wht/Blu

Wht/Yel

Wht/Blk(not used)

Auto / Manual Selector

Manual Switch

10 & 15 AmpRIBU1SCRIBH1SCRIBTU1SCRIBTH1SCRIBMU1SCRIBMH1SC

RIBU1S vs. RIBU1SCStock model RIBU1SC for relay control applications that require true-HOA on either N/O or N/C. No jumpers and no wrong orders.

24 Vac FromController

24 Vac FromController

Wht/Blu

Wht/Yel

Wht/Blu

Wht/Yel

RIBU1S

RIBU1SC

120 Vac

120 Vac

Orange

OrangeLOAD

LOAD

N/O or N/C, you choose

Yellow

Orange (N/O)

Blue (N/C)

RIBU1S has a lower costbut if N/C is desired onrelay, it must be speciedwhen ordering.

RIBU1SC is an alternativeto the RIBU1S that allowsone item to be ordered - noneed to specify N/O or N/C.

20 AmpRIB2401SBCRIB2402SBCRIBT2401SBCRIBT2402SBCRIBM2401SBCRIBM2402SBC

10 & 15 AmpRIBU1SCRIBH1SCRIBTU1SCRIBTH1SCRIBMU1SCRIBMH1SC

20 AmpRIB2401SBCRIB2402SBCRIBT2401SBCRIBT2402SBCRIBM2401SBCRIBM2402SBC

Digital In

Dry Contact Feedback Signal (when device is in manual position)

Analog Out

Analog Out

24 Vac/dc

RIBMNA1D0

Controller

Load

Manual Analog Override SwitchInitial installation or trouble shooting can be smoother and much less costly by adding the RIBMNA1D0. It allows you to manually control an analog output without accessing complicated algorithms in a controller. An indicator is provided for visual confirmation of percentage output. When you are finished, you can switch back to auto to put the controller back in control.

Page 5: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

4 Functional Devices, Inc. : American Made. American Owned.

Limit Extra Transformers with Dry Contact Input RelaysEliminate the expense of extra transformer(s) and associated wiring.

Controller

120 Vac

Cont. Pwr.

Enclosure

DRY

CONTACTS

D.O.1

D.O.2

D.O.3

40VA

100VA

24 Vac

RIBU1C's

24 Vac

Controller

120 Vac

Cont. Pwr.

Enclosure

DRY

CONTACTS

D.O.1

D.O.2

D.O.3

40VA

24 Vac

Dry ContactInput RIB's

Before

After

Detect Water Levels with Dry Contact Input RelaysIf the water touches the wires, the relay will turn on (closes COMMON to N/O and opens COMMON to N/C.)Uses UL Approved low-voltage to sense water and activate relay.

ControlCircuit

Water Pan

Dry Contact Input Relay

Any typical non-corrosiveprobes may be used.

Relay Load

120-277 Vac Power

Enclosed RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)

Track RelaysRIBM01ZNDCRIBM02ZNDCRIBM013PNDC

Enclosed RelaysRIB21CDCRIB01BDCRIB01SBDCRIB02BDCRIB02SBDCRIBD01BDC (Time Delay)RIBD02BDC (Time Delay)RIBD01BDC-DOB (Time Delay)RIBD02BDC-DOB (Time Delay)

Track RelaysRIBM01ZNDCRIBM02ZNDCRIBM013PNDC

Monitoring Switch Position with a ControllerDigital In 1 and 2 of the controller can be used to monitor the position of the HOA switch. The controller can be programmed to log the status of the HOA and provide a warning if the switch is in an override position.

60 Hz ac

Controller

10-30Vac/dc

Common

120 Vac Not Used

Closed

Auto

Common

Load

RelayDigital Out

Common

Digital In 1

Digital In 2

Common

SwitchPole #2

SwitchPole #1

AutoCommon

Enclosed Relays10 AmpRIBU1SMRIBH1SM

Track Relays15 AmpRIBMU1SMRIBMH1SMRIBMNU1SMRIBMNH1SM

DI 1 DI 2 ResultOpen Open Overridden OffOpen Closed Auto

Closed Open Overridden OnClosed Closed Error Condition

Page 6: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

5800.888.5538 : www.FunctionalDevices.com

High Voltage Optoisolated RelaysOptoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs.

Controller

Digital Out

(or Analog Out)

Relay

OptoInput

PowerSupply

60 Hz ac

Load

Opto RIB®

Enclosed RelaysRIBTE01BRIBTE02BRIBTE01SBRIBTE02SBRIBTE01PRIBTE02P

Low Voltage Optoisolated RelaysOptoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from low power digital or analog outputs.

Controller

Analog or Digital Out

24 Vac/dc

Relay

OptoInput

PowerSupply

60 Hz ac

Load

Opto RIB®

Enclosed RelaysRIBTELCRIBTELSRIBTE24BRIBTE24SBRIBTE24P

Polarized RelaysRelays are polarized to work in a supervised system and may be turned on and off by reversing polarity.For fire alarm systems, smoke control systems, etc.

Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P

Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P

Enclosed RelaysRIB12C-FARIB24C-FARIB12S-FARIB24S-FARIBT24B-FARIB24P-FA

Track RelaysRIBMN12C-FARIBMN24C-FARIBMN12S-FARIBMN24S-FA

Controller

End of Line

Resistor

Load

Signaling Circuit

RIB24C-FACoil

+ –

Load

+ –

RIB24C-FACoil

Page 7: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

6 Functional Devices, Inc. : American Made. American Owned.

Condense Work Space and Wiring (Power Control)Power Control Centers allow you to save large amounts of time, space, and wiring throughout your panel.

Enclosure

ConduitPower Control Center is pre-wired

By using one of Functional Devices' Power ControlCenters you will greatly reduce installation time, aswell as save space in your enclosure.

Before After

There is a lot of extra wiring in this enclosurewhich not only takes up space but also increasesthe diculty and time associated with installation.

Sub-Panel

To remainderof panel

Switch, Breaker &Indicator Light

Enclosure

Conduit

Sub-PanelTo remainderof panel

Fuse

SwitchHNGHNG

Enclosed 4 AmpPSPT2RB4PSPW2RB4

Condense Work Space and Wiring (Power Supplies)The PSC, PSH, and PSB Series Power Supplies allow you to save large amounts of time, space, and wiring throughout your panel.

Enclosure

ConduitPower Supplies are pre-wired

By using one of Functional Devices' PowerSupplies you will greatly reduce installationtime, as well as save space in your enclosure.

Before After

There is a lot of extra wiring in this enclosurewhich not only takes up space but also increasesthe diculty and time associated with installation.

Sub-Panel

120Vac from10A Switch &CB to remainderof panel

Enclosure

Conduit

Sub-PanelTo remainderof panel

Fuse

SwitchHNGHNG

24Vac Power Supply

24Vac Switch/Breaker

24Vac 24VacIndicator

Main Power10A Switch/CB & Indicator Light

Power SuppliesAny models ending in “B10” in the PSC, PSH, or PSB Power Supply Series

Switch in a Box Enclosed ControlsPre-labeled 20 Amp switches are great for new installations or last minute corrections to controls jobs. Switch labels may be custom selected when ordering.

To A/CPower In

SummerWinter Heat

(Winter)Cool

(Summer)

2 Position

HandO

AutoContactor

3 Position

Coil

Controller

Digital Out

24 Vac

Contactor CoilHand

OAuto

24Vac Transformer

DO From Controller

2 PositionSIB04SSIB05S

3 PositionSIB02SSIBLS

Enclosed 10 AmpPSPT2RB10PSPW2RB10

Page 8: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

7800.888.5538 : www.FunctionalDevices.com

Electronic Air CleanerModels RIBXGHF, RIBXGHTF, RIBXGHA, or RIBXGHTA can be used to control an electronic air cleaner based on whether or not the blower motor is turned on.

120Vac Source

Blower

Motor

LO

HI

C

Neutral

RIBXGHF, RIBXGHTF, RIBXGHA, or RIBXGHTA

When current drawn by Blower Motor exceeds RIBXGH threshold, SPST

contacts connect 120Vac source to

line input of Air Cleaner.

Electronic Air Cleaner

Humidifier ControlSolid and split core current sensors can be used along with a humidistat for control of a humidifier based on whether or not the blower motor is turned on.

24Vac

COM

Blower

Motor

LO

HI

C

Humidier

Humidistat

Enclosed MiniCurrent Sensor

Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTARIBXGFRIBXGTFRIBXGARIBXGTA

Occupancy Sensor on Open Protocol NetworkA LonMark® certified or a BACnet® compatible relay with a digital input can be used with an occupancy sensor in a room and turn on and off loads based on that status. This saves the cost of buying a LonMark® compatible or BACnet® compatible occupancy sensor by utilizing the digital input on our device.

LonMark® Certifed orBACnet® Compatible Relay

Class II Dry Contact Input

Network

24 Vac/dc

LineNeutral

LoadOrg Yel

Occupancy Sensor

LonMark® Certified Relays RIBTW2401B-LNRIBTW2402B-LNRIBTW2401SB-LNRIBTW2402SB-LN

BACnet® Compatible Relays RIBTW2401B-BCRIBTW2402B-BC

Page 9: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

8 Functional Devices, Inc. : American Made. American Owned.

Loop-Powered RIBXK420 Series and RIBXG420 Series (High-Accuracy)

Enclosed Mini Current SensorsRIBXK420-20RIBXK420-50RIBXK420-100RIBXG420-20RIBXG420-50RIBXG420-100

DC Supply

- + RED +

Load Wire

BLACK -*Add 250 Ohms for 1-5 Vdc Analog In

Controller

- + 4-20 mA Analog In*1-5 Vdc Analog In

Mini Current Sensor

Load

MotorStarter

Line

Ope

n Co

ver

Hands and tools exposedto high voltage while

adjusting potentiometer ofcurrent sensor

( OLD WAY )

Danger!!!

Load

MotorStarter

Hands safely awayfrom high voltage because

SCAL adjusts itself

Clos

ed C

over

( NEW WAY )

Line

Screwdriver

Safe

NewRIBXGA-SCAL

OldManual Sensor

Self-Calibrating Current SensorsRIBXGA-SCALRIBXGTA-SCAL

Self-Calibrating Current SensorsThe self-calibrating current sensor begins its 30 second self calibration process the first time current is applied within the operating range. This procedure uses the user selected differential to set the trip threshold at a 15% or 25% level. Selection is completed prior to install using the appropriate DIP switch setting, keeping the installer’s hands away from possible shock hazard, as well as saving installation time.

250Ω

DC Supply

- +RED +

Load Wire

BLACK -*Add 250 Ohms for 1-5 Vdc Analog In

Mini Current Sensor

Enclosed Mini Current SensorsRIBXK420-20RIBXK420-50RIBXK420-100RIBXG420-20RIBXG420-50RIBXG420-100

Enclosed RelaysRIBTELCRIBTELSRIBTE24BRIBTE24SBRIBTE24P

Track RelaysRIBME2401BRIBME2402BRIBME2401SBRIBME2402SBRIBME2401PRIBME2402P

Control Optoisolated Relay with 4-20mA LoopAdd 250Ω across Optoisolated Relay 5-25 Vdc control input. Relay turns on at approximately 10mA and off at 8mA.

Page 10: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

9800.888.5538 : www.FunctionalDevices.com

Echelon® Thermistor-In ApplicationA thermistor is used to read the temperature of a room or area. That data is fed back to the LonWorks® system. When the temperature is out of range, the relay is commanded by the network, activating the exhaust fan, heater, or other device. A current sensor is used to feed back load status to the network. If there is a command and status mismatch, the network can issue an alarm to the operator’s console.

ThermistorFT-10 Network

24 Vac/dc

COM

Digital Input

Relay Output

Line

Exhaust Fan Heater

NeutralRIBX Series

Room or Area

or

LonMark® Compatible RelayEnclosed RelayRIBTW24SB-LNT2RIBTW24SB-LNT3

Track RelayRIBMW24SB-LNT2RIBMW24SB-LNT3

Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTA

FT-10 Network

24 Vac/dc

COM

LonMark® Certied Relay & Current Sensor

Exhaust Fan Heater

or

A/C Line Power

Relay

InternalCurrentStatus

Echelon® Relay / Current Sensor ApplicationSave time, money, and messy wiring. LonMark® certified relay contains an internal current sensor for load status. Relay control and load status are easily accessible from the FT-10 Network.

Enclosed ModelRIBTWX2401SB-LN RIBTWX2402SB-LN

Track ModelRIBMNWX2401SB-LN RIBMNWX2402SB-LN

RIBXGFRIBXGTFRIBXGARIBXGTARIBXGFLRIBXGTFL

Page 11: Application Manual - Functional Devices, Inc.€¦ · 800.888.5538 3 Damper Motor Control with True-HOA The damper motor can be stopped in mid position for debugging. When auto/manual

10 Functional Devices, Inc. : American Made. American Owned.

Delay on Break (DOB) Time DelayLoad 2 stays on selected amount of time after load 1 goes off.

Yel

Blu

Wht/Yel

Wht/Brn

Yel

Blu

In this example, voltage can be any voltage from 120-277 Vac.

Neutral

RIBD2421CRIB®Select RIB® with coil input

appropriate to sense Load 1.

Load 2(Circulating Fan,

for example)

Load 1(Thermostat Controlled

Heater, for example)

Time Delay RelaysRIBD2421C

FT-10 Network

24 Vac/dc

COM

RIBMW24SB-LNAI or RIBTW24SB-LNAI

Digital Input

Relay Output

Line

HVAC Fan

NeutralRIBX Series

DierentialPressure

Transducer

Air Filter+5Vdc or+10Vdc

COM

Enclosed RelayRIBTW24SB-LNAI

Track RelayRIBMW24SB-LNAI

Enclosed Mini Current SensorsRIBXKFRIBXKTFRIBXKARIBXKTA

Echelon® Analog-In ApplicationSimple and easy load control and status along with analog input provide everything needed to control and interface to your HVAC application. Save the expense of a controller for smaller remote jobs or complete larger jobs, as well.

RIBXGFRIBXGTFRIBXGARIBXGTARIBXGFLRIBXGTFL

Neutral

Fan

Local Power

Wire NutOrg

Yel

Blu

Wht/BlkWht/Blk

Neutral Hot

Wht/Red

Wht/Blu

DryContact

Wires

NormallyClosedSwitch

(Not provided)

RIBD01BDC – 120 Vac operation

RIBD02BDC – 208-277 Vac operation

Enclosed RelaysRIBD01BDCRIBD02BDC

Activate Load for Pre-Determined Time Using Dry Contact Input / Time Delay Relay and Normally Closed Switch

• Activate (open) switch until load comes on.• Release switch.• Load will be powered until time delay exprires.

AM578M 05.21.15