Application Guide - Viessmann

80
Application Guide Vitodens 200-W B2HA,B2HB Residential Boiler

Transcript of Application Guide - Viessmann

Page 1: Application Guide - Viessmann

Application Guide

Vitodens 200-W B2HA,B2HBResidential Boiler

Page 2: Application Guide - Viessmann

II

Page 3: Application Guide - Viessmann

III

Application Guide

The application examples contained in this document serve as a guideline only. These are not engineered drawings and are not intended to replace project designs provided by a professional engineer. It is the responsibility of the installing contractor to ensure all aspects of the system comply with the local authorities having jurisdiction.

© 2017 by Viessmann. All rights reserved.

No part of this book may be used or reproduced in anymanner whatsoever without prior written permission.

For information, contact:

Viessmann Manufacturing Company Inc.750 McMurray RoadWaterloo ON, N2V 2G5, Canada

Phone: 519-885-6300Toll Free: 800-387-7373

www.viessmann.ca

Page 4: Application Guide - Viessmann

IV

Page 5: Application Guide - Viessmann

1

Each day Viessmann heating systems face a wide variety of requirements and challenges here in North Ameri-ca, and around the world. Whether in historically protected homes, modern commercial buildings, or in large facil-ities, Viessmann products meet every demand and offer solutions for all your needs: wood, oil, or gas fired boilers for both residential and commercial use, from 12KBTU to 17.9MMBH (4 to 5263kW), domestic hot water storage tanks, solar collectors, Biogas technol-ogies, and much more.

Viessmann also sets the standard for operational reliability, operating comfort, environmental friendliness and a long service life. All Viessmann products have one thing in common: they are based on a modular

technology strategy with one common platform. This way, different product versions can be created to fulfill each customer’s specific requirements. In short, Viessmann takes care of all your needs, from start to finish.

Part of that is a comprehensive sup-port program: A knowledgeable Viess-mann sales representative network, technical training academy, and technical support personnel assist you right from the planning stage through to the installation and start-up phase of a project.

With Viessmann you are witnessing intelligent, high-tech boiler technology at work. We have selected some of the most interesting Viessmann appli-cations from across North America for your reference.

Pre-Face / Overview

Page 6: Application Guide - Viessmann

2

AH2 ... ... ...B

Fuel Types

Effi ciency

� Low Temperature A F

� Condensing B J

� CHP C

Gas Oil

Generation of Boiler

Consecutive Number

A B C ...

Heat Only Circuit Combi Combi Comfort Coiled Tubing Tank Stratifi ed Loading tank Solar Heating For DHW Solar Heating

Wall-Mounted G H J K - L - -

Floor Standing - R - - S T U V

Series P

Segment 100 1

200 2

300 3

Identifying Boiler NomenclatureIdentifying Boiler Nomenclature

Page 7: Application Guide - Viessmann

3

X2VD 2ZC ZP 01I2

Number of boilers in system Number of heating circuits

1, 2, 3 ...

Number of individual zones in system

Drawing version

How system is zoned

ZP Pumps

ZV Zone Valves

TV Thermostatic Radiator Valves

C Combination

Type of Circuits:

HC Heating Circuit

ZC Zone Circuit

HC/ZC Combination System

Boiler Segment

VD Vitodens

CU

CM Vitocrossal

CT

VR Vitorond

Segment / Series

1 100 Series

2 200 Series

3 300 Series

Domestic Capability

X No DHW

I With indirect DHW

C On demand DHW

T Stratifi ed Loading Tank

Identifying Boiler NomenclatureIdentifying Application Codes

Page 8: Application Guide - Viessmann

4

RECOMMENDED PRODUCT APPLICATIONS

Medium120 -160 °F

Low80 -120 °F

High160 -190 °F

Medium140 -160 °F

High160 -190 °F

1 1

2

2

1 1

Medium120 -180 °F

Refer to Technical Data Manual of each product for applicable certifications. Technical information subject to change without notTT ice.

Best Choice

Possible with limitationsNot recommended

1- Limited maximum boiler supply water temperature.2- Ensure boiler protection to prevent against low return water temperature

Baseboard / Fan Coil

Cast Iron Radiator

Panel Radiator

Radiant Floor Heating

Indirect DHW

Air Handlers

Vitodens

100

Vitodens

200/222-F

Vitorond

100

Vitocrossal

300 CU3A

Typical Supply

Temperature

Application

Page 9: Application Guide - Viessmann

5

Vitodens 200 accessories kit with pressure relief and purge valves.

Ball valve Circulator with isolation fl anges Aquastat Secondary low water cut-off

Low loss header Thermostatic mixing valve Radiant infl oor manifold Motorized mixing valve Outdoor temperature sensor

Panel radiator Flow check valve Hot water baseboard radiator Thermostat Temperature sensor

Boiler water feed with double back check valve

Air eliminator Expansion tank Viessmann Vitotrol Multi-zone control

Purge assembly: (sediment faucet and ball valve)

Zone valve Hydronic air handler 24V Zone valve Circulator

Towel radiator Viessmann 3-way mixing valve with actuator motor

Plate and frame heat exchanger 120 volt power

Hydronic Components Electrical Components

Component Index

Page 10: Application Guide - Viessmann

6

Page 11: Application Guide - Viessmann

7

Vitodens 200

Application # Application Code Page

Application 1 - VD2X 1ZC1ZP.01 28

Application 2 - VD2I 1ZC4ZV.01 32

Application 3 - VD2I 1ZC4ZP.01 36

Application 4 - VD2I 2ZC2ZP.01 40

Application 5 - VD2I 3HC/ZC3ZP.01 44

Application 6 - VD2I 3HC/ZC3ZP.02 48

Application 7 - VD2I 3ZC9C.01 52

Application 8 - 2VD2I 3HC/ZC3ZP.01 56

Application 9 - 2VD2X 3HC3ZP.01 60

Application 10 - 4VD2I 2HC2ZP.01 64

Microload - Microload 68

Page 12: Application Guide - Viessmann

8

Product may not be exactly as shown

The flue gas temperature is only approximately 9-27ºF (5-15ºC) above boiler return temperature (see chart below).

A Inox-Radial heat exchanger made from stainless steel – for high operational reliability and a long service life. Large heating output in the smallest of spaces

B Modulating MatriX cylinder burner for extremely clean combustion and quiet operation

C Variable speed combustion fan for quiet and economical operation

D Gas and water connections

E Digital boiler control unit

Delivered condition

Wall mounted gas condensing boiler with Inox-Radial heat exchanger, modulating MatriX cylinder burner for natural gas and LPG, plus wall mounting bracket. Vitotronic 200 for weather-compensated operation. Preset for operation with natural gas. Fully plumbed and wired. White epoxy-coated casing.

Vitodens 200-W B2HB 19, 26, 35, 45, 57 Cross-Section

Product Information

Vitodens 200-W, Technical Data

Page 13: Application Guide - Viessmann

9

Cross-Section

Products may not be exactly as shown

A Inox-Radial heat exchanger made from stainless steel – for high operational reliability and a long service life. Large heating output in the smallest of spaces

B Modulating MatriX cylinder burner for extremely clean combustion and quiet operation

C Variable speed combustion fan for quiet and economical operation

D Gas and water connections

E Digital boiler control unit

Delivered condition

Wall mounted gas condensing boiler with Inox-Radial heat exchanger, modulating MatriX cylinder burner for natural gas and LPG, plus wall mounting bracket. Vitotronic 200 for weather-compensated operation. Preset for operation with natural gas. Fully plumbed and wired. White epoxy-coated casing.

Vitodens 200-W B2HA 88, 100, 112, 150

The flue gas temperature is only approximately 9-27ºF (5-15ºC) above boiler return temperature (see chart below).

Product Information

Vitodens 200-W, Technical Data

Page 14: Application Guide - Viessmann

10

*1 Output based on 140ºF (60ºC), 120ºF (49ºC) system supply/return temperature.*2 Net AHRI rating based on piping and pick-up allowance of 1.15.*3 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator must be installed upstream of the heating system.*4 See “Waterside Flow” starting on page 8 in this manual.

19, 68 26, 94 35, 125 45, 160 57, 199BH2B W-002 .oN ledoM relioB

CSA input Natural Gas (NG)

CSA input Liquid Propane Gas (LPG)

CSA output/DOE *1heating capacity NG

CSA output/DOE *1

heating capacity LPG

Net AHRI rating *2

MBH(kW)

MBH(kW)

MBH(kW)

MBH(kW)

MBH(kW)

12-68(3.5-20)

12-68(3.5-20)

11-64(3.2-19)

11-64(3.2-19)

55(16)

19-94(5.5-27)

19-94(5.5-27)

18-88(5-26)

18-88(5-26)

77(22)

19-125(5.5-37)

19-125(5.5-37)

18-117(5-34)

18-117(5-34)

102(30)

32-160(9-47)

60-160(17.5-47)

30-149(9-44)

56-149(17-44)

127(37)

32-199(9-58)

60-199(17.5-58)

30-185(9-54)

56-185(17-54)

160(47)

Heat exchanger surface area ft.2(m2)

12.96(1.2)

12.96(1.2)

12.96(1.2)

31.99(2.9)

31.99(2.9)

Min. gas supply pressure

Natural gasLiquid propane gas

“w.c.“w.c.

410

410

410

410

410

Max. gas supply pressure *3Natural gasLiquid propane gas

“w.c.“w.c.

1414

1414

1414

1414

1414

A.F.U.E. % 95.0 95.0 95.0 95.0 95.0

Weight lbs(kg)

110(50)

110(50)

110(50)

210(95)

210(95)

Boiler water content USG(L)

1.02(3.88)

1.02(3.88)

1.02(3.88)

3.85(14.6)

3.85(14.6)

Boiler max. flow rate *4 GPM(L/h)

6.2(1400)

6.2(1400)

6.2(1400)

14.3(3250)

14.3(3250)

Max. operating pressure

at 210ºF (99ºC)psig(bar)

45(3)

45(3)

45(3)

60(4)

60(4)

Boiler water temperature

- Adjustable high limit (AHL) range space heating (steady state) DHW production

- Fixed high limit (FHL)

ºF(ºC)

ºF(ºC)

ºF (ºC)

68 to 180(20 to 82)

165(74)

210 (99)

68 to 180(20 to 82)

165(74)

210 (99)

68 to 180(20 to 82)

165(74)

210 (99)

68 to 180(20 to 82)

165(74)

210 (99)

68 to 180(20 to 82)

165(74)

210 (99)

Boiler connections

Boiler heating supply and return Pressure relief valve Drain valve

Boiler supply/return for indirect-fired DHW storage tank (field supplied)Gas valve connection

NPTM”NPTF”(male

thread)

NPT”

NPTF”

¾¾¾

¾

¾

¾¾¾

¾

¾

¾¾¾

¾

¾

1b¾¾

1b

1

1b¾¾

1b

1

Product Information

Vitodens 200-W, Technical Data

Page 15: Application Guide - Viessmann

11

*5 Measured flue gas temperature with a combustion air temperature of 68°F (20°C).

*6 Based on maximum input rate.

*7 Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200-W, B2HB for details.

*8 For side wall vent installations (coaxial system): Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200-W, B2HB Venting System. Do not attempt to common-vent Vitodens 200-W B2HB 19, 26, 35 with any other appliance. The Vitodens 200-W B2HB 45, 57 can only be common vented with other Vitodens 200-W boilers of the same size and series. Side wall co-axial vent installation must include Viessmann protective screen! For details refer to the Installation Instructions for the Vitodens 200-W, B2HB Venting System. For information regarding other Viessmann System Technology componentry, please reference documentation of respective product.

Note: For high altitude installation at 10,000 ft. the input for model B2HB 19 to 57 will have an altitude de-ration of 21%.

Boiler Model No. 200-W B2HB

Dimensions

Overall depth

Overall width

Overall height

inches(mm)

inches(mm)

inches(mm)

15.7(400)17¾(450)41

(1040)

15.7(400)17¾(450)41

(1040)

15.7(400)17¾(450)41

(1040)

21(530)19

(480)43½

(1105)

21(530)19

(480)43½

(1105)

Flue gas *5Temperature (at boiler return temperature of 86ºF (30ºC)- at rated full load- at rated partial load

Temperature (at boiler return temperature of 140ºF (60ºC)

ºF (ºC)ºF (ºC)

ºF (ºC)

113 (45)95 (35)

154 (68)

113 (45)95 (35)

154 (68)

113 (45)95 (35)

154 (68)

95 (35)91 (33)

149 (65)

104 (40)95 (35)

158 (70)

Max. condensate flow rate *6with natural gas andTS/TR =122/86ºF (50/30ºC) USG/h

(L/h)0.66(2.5)

0.97(3.7)

1.21(4.6)

1.55(6.0)

2.0(8.0)

Condensate connection *7 hose nozzle

Ø in ¾-1 ¾-1 ¾-1 ¾-1 ¾-1Boiler flue gas connection *8 Ø

in (mm) 2 3/8 (60) 23/8 (60) 23/8 (60) 3¼ (80) 3¼ (80)

Combustion air supply

connection (coaxial) outerØ in

(mm)4

(100)4

(100)4

(100)5

(125)5

(125)Sound Rating

- at maximum input- at minimum input

dBdB

4135

4836

5136

5639

6739

19, 68 26, 94 35, 125 45, 160 57, 199

Product Information

Vitodens 200-W, Technical Data

Page 16: Application Guide - Viessmann

12

*A For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 88,100 and 150 will have an altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m) average of 2.8% / 1,000 ft. (305 m). *B The input for model B2HA 112 at 10,000 ft. (3000 m) will have an input de-rate of 13%.*C Net AHRI rating based on piping and pick-up allowance of 1.15.

*1 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator must be installed upstream of the heating system.*2 See “Waterside Flow” starting on page 10 of this manual.*3 Output based on 180ºF (82ºC), 80ºF (26ºC) system supply/return temperature.

* 88AH2B .oN ledoM relioB A 100 *A 112 *B 150 *A

CSA input Natural Gas (NG)

CSA input Liquid Propane Gas (LPG)

CSA output NG *3

CSA output LPG *3

MBH(kW)

MBH(kW)

MBH(kW)

MBH(kW)

71-311(21-91)

104-311(30-91)

67-294 (20-86)

98-294(29-86)

71-352(21-103)

104-352(30-103)

67-333(20-98)

98-333(29-98)

113-399(33-117)113-399(33-117)

103-375(30-110)

103-375(30-110)

113-530(33-155)113-530(33-155)

103-495(30-145)

103-495(30-145)

DOE/AHRI Gross output

Net AHRI Rating *C

MBH(kW)MBH(kW)

292(85)254(74)

329(96)286(84)

371(109)323(95)

490(144)426

(125)Heat exchanger surface area ft.2

(m2)28.88(2.68)

28.88(2.68)

36.78(3.41)

36.78(3.41)

Min. gas supply pressure

Natural gasLiquid propane gas

“w.c.“w.c.

410

410

410

410

Max. gas supply pressure *1Natural gasLiquid propane gas

“w.c.“w.c.

1414

1414

1414

1414

CSA thermal/combustion efficiency

ANSI Z21,13/CSA 4.9 % 94.5 94.5 93.9 93.5Weight lbs

(kg)194(88)

194(88)

298(135)

298(135)

Boiler water content USG(L)

3.4(12.8)

3.4(12.8)

4(15)

4(15)

Boiler max. flow rate *2 GPM(L/h)

25(5700)

25(5700)

37.9(8600)

38(8600)

Max. operating pressure

at 210ºF (99ºC)psig(bar)

60(4)

60(4)

80(5.5)

80(5.5)

Boiler water temperature

- Adjustable high limit (AHL) range space heating (steady state) DHW production

- Fixed high limit (FHL)

ºF(ºC)

ºF(ºC)

ºF (ºC)

68 to 185(20 to 85)

176(80)210 (99)

68 to 185(20 to 85)

176(80)210 (99)

68 to 185(20 to 85)

180(82)210 (99)

68 to 185(20 to 85)

180(82)210 (99)

Boiler connections

Boiler heating supply and return Pressure relief valve Drain valve

Boiler supply/return for indirect-fired DHW storage tank (field supplied)Gas valve connection

NPTM”NPTF”(male

thread)

NPT”

NPTF”

1½¾¾

1

1½¾¾

1

2¾¾

2

1

2¾¾

2

1

Product Information

Vitodens 200-W, Technical Data

Page 17: Application Guide - Viessmann

13

*A For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 88,100 and 150 will have an altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m) average of 2.8% / 1,000 ft. (305 m).

*B The input for model B2HA 112 at 10,000 ft. (3000 m) will have an input de-rate of 13%.

*4 Measured flue gas temperature with a combustion air temperature of 68°F (20°C).

*5 Based on maximum input rate.

*6 Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200-W, B2HA for details.

*7 For side wall vent installations (coaxial system): Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200-W, B2HA Venting System. Side wall co-axial vent installation must include Viessmann protective screen! For details refer to the Installation Instructions for the Vitodens 200-W, B2HA Venting System. The Vitodens 200-W can only be common vented with other Vitodens 200-W boilers of the same size and series. For details refer to the Common Venting Manual.

*8 Add approximately 2½ inches (65 mm) for coaxial vent pipe transition adaptor.

For information regarding other Viessmann System Technology componentry, please reference the documentation of each respective product.

* 88AH2B .oN ledoM relioB A 100 * A 112 * B 150 * A

Dimensions

Overall depth

Overall width

Overall height *8

inches(mm)

inchesmm)

inchesmm)

21(530)

19(480)43½

(1105)

21(530)

19(480)43½

(1105)

27.1(698)23 5/8

(600)44½

(1128)

27.1(698)23 5/8

(600)44½

(1128) Flue gas *4Temperature (at boiler return temperature of 86ºF (30ºC)- at rated full load- at rated partial load

Temperature (at boiler return temperature of 140ºF (60ºC)

ºF (ºC)ºF (ºC)

ºF (ºC)

135 57)99 37)

162 72)

135 (57)99 (37)

162 (72)

124 (51)102 (39)

158 (70)

140 (60)102 (39)

165 (74)

Max. condensate flow rate *5for NG and LPGTS/TR =104/86ºF (40/30ºC) USG/h

(L/h)3.1

(11.7)3.5

(13.1)4.35

(16.5)5.28

(20.0)

Condensate connection *6 hose nozzle

Ø in. ¾- 1 ¾- 1 ¾- 1 ¾- 1

Boiler flue gas connection *7 Øin. (mm) 4 3/8 (110) 4 3/8 (110) 4 3/8 (110) 4 3/8 (110)

Combustion air supply

connection (coaxial) outer

Ø in. (mm) 6 (150) 6 (150) 6 (150) 6 (150)Sound Rating

- at maximum input- at minimum input

dBdB

6938

6938

5740

6140

Product Information

Vitodens 200-W, Technical Data

Page 18: Application Guide - Viessmann

14

Boiler Dimensions - Models 200-W, B2HB 19, 26, 35

Vitodens 200-W, Technical Data

Page 19: Application Guide - Viessmann

15

Legend

A Boiler supply, 1 ½”B Gas connection, 1” NPTFC Boiler return, 1 ½”D Recommended height (single boiler system)E Condensate drain

Boiler Dimensions - Models 200-W, B2HB 45, 57

Vitodens 200-W, Technical Data

Page 20: Application Guide - Viessmann

16

Legend

A Boiler supplyB Gas connection, 1” NPTFC Boiler returnD Recommended height (single boiler system)E Condensate drain

Boiler Dimensions - Model B2HA 88, 100

Vitodens 200-W, Technical Data

Page 21: Application Guide - Viessmann

17

Legend

A Boiler supplyB Gas connection, 1” NPTFC Boiler returnD Recommended height (single boiler system)E Condensate drain

Boiler Dimensions - Models B2HA 112, 150

Vitodens 200-W, Technical Data

Page 22: Application Guide - Viessmann

18

Recommended minimum service clearances

Minimum clearances to combustibles

AL= AlcoveCL= Closet

*1 Refer to the Installation Instructions of the Vitodens 200-W, B2HB Venting System for details.

Note:The Vitodens boiler has passed the zero inches vent clearance to combustibles testing requirements dictated by the Harmonized Standard ANSI Z21.13. CSA 4.9 (latest edition) and therefore is listed for zero clearance to combustibles when vented with a single wall special venting system (AL-29-4C material). The zero inches vent clearance to combustibles for the Vitodens boiler supercedes the clearance to combustibles listing that appears on the special venting system label.

Top Front Rear Left Right Vent pipe *1

0 0 AL, CL 0 0 0 0

Service Clearances

Vitodens 200-W, Technical Data

Page 23: Application Guide - Viessmann

19

Waterside Flow (primary circuit)

The Vitodens 200-W, B2HB is designed for closed loop, forced circulation hot water heating systems only. Use standard friction loss method for pipe sizing. Observe boiler maximum and minimum flow rate limitations. If system flow rate exceeds boiler maximum flow rate (as stated above), falls below the minimum flow rate or if system flow rate is unknown, Viessmann strongly recommends the installation of a low-loss header. An alternative method may be used, such as primary secondary piping using closely spaced tees.

A low-loss header offers additional benefits not provided by a pair of closely spaced tees. Viessmann therefore strongly recommends and prefers the use of a low-loss header over closely spaced tees. See pages 25 and 26 for low-loss header information. Once the low-loss header is connected, the built-in low-loss header logic of the Vitodens 200-W boiler ensures the required �t across the system through the sensory communication between the low-loss header and the boiler.

Flow rate

Su

pp

ly h

ead

pre

ssu

re (

wat

er) Pressure drop (primary circuit) for

Vitodens 200-W, B2HB 19, 26, 35For sizing an on-site circulation system.Max. flow rate: 6.2 GPM (1400 L/h)

Pressure drop (primary circuit) for Vitodens 200-W, B2HB 45 - 57For sizing an on-site circulation system.Max. flow rate: 14.3 GPM (3250 L/H)

Waterside Flow

Vitodens 200-W, Technical Data

Page 24: Application Guide - Viessmann

20

Sup

ply

head

pre

ssur

e (w

ater

)

Flow rate

Sup

ply

head

pre

ssur

e (w

ater

)

Flow rate

The Vitodens 200-W, B2HA is designed for closed loop, forced circulation hot water heating systems only. Use standard friction loss method for pipe sizing. Observe boiler maximum and minimum flow rate limitations. If system flow rate exceeds boiler maximum flow rate (as stated below), falls below the minimum flow rate or if system flow rate is unknown, Viessmann strongly recommends the installation of a low-loss header. An alternative method may be used, such as primary secondary piping using closely spaced tees.

Pressure drop (primary circuit) for Vitodens 200-W, B2HA 88, 100 For sizing an on-site circulation system.Max. flow rate: 25 USGPM (5700 L/h)

Pressure drop (primary circuit) for Vitodens 200-W, B2HA 112, 150For sizing an on-site circulation system.Max. flow rate: 38 USGPM (8600 L/h)

A low-loss header offers additional benefits not providedby a pair of closely spaced tees. Viessmann thereforestrongly recommends and prefers the use of a low-lossheader over closely spaced tees. Once the low-loss headeris connected, the built-in low-loss header logic of theVitodens 200-W boiler ensures the required �t across thesystem through the sensory communication between thelow-loss header and the boiler.

Waterside Flow (primary circuit)

Vitodens 200-W, Technical Data

Page 25: Application Guide - Viessmann

21

Viessmann offers a variety of Grundfos heating circuit/boiler pumps which meet typical Vitodens system installation requirements (see “Heating circuit pump (field supplied)” or “Boiler pump (field supplied)” in the Installation Examples starting on page 28). See tables below for recommended pumps. Refer to the graph on page 8 for the proper waterside boiler friction loss calculations. The following pumps have been selected based on boiler heat exchanger head loss and boiler piping to a low-loss header.

IMPORTANT

Pump selection must be based on accurate system flow

and pressure drop calculations (includes DHW sizing).

53 BH2B62 BH2B91 BH2BledoM

Flow rate

20ºF �t GPM (L/h) ----)3541( 4.6

25ºF �t GPM (L/h) 5.1 ----)3611(30ºF �t GPM (L/h) 4.3 (969) 5.9 --)2331(35ºF �t GPM (L/h) 3.7 (830) 5.0 --)2411(40ºF �t GPM (L/h) 3.2 (727) 4.4 (999) 5.9 (1328)Flow limitation GPM (L/h) 6.2 (1400) 6.2 (1400) 6.2 (1400)Recommended boiler pumps Grundfos UPS 15-58 (3-speed), Taco 0015, Wilo Star S 21 FX

Before using the following pumps for a DHW tank application, find out the proper pressure drop through thetank, the required temperature difference through the coil and system piping head loss of the domestic hot water.

Heating Circuit / Boiler Pumps

Pump Selection

Model B2HB 45 Flow rate

GPM (L/h)

Boiler pressure drop

ft. (m)

Recommended

pump option 1

Grundfos

Recommended

pump option 2

Grundfos

20º F �t --------25º F �t 11.9 (2707) 15.4 (4.7) UPS 26-99FC, 115V, Speed2 UP 26-64F, 115V30º F �t 9.9 (2256) 10.4 (3.2) UPS 26-99FC, 115V, Speed2 --35º F �t 8.5 (1934) 8.0 (2.5) UPS 26-99FC, 115V, Speed1 --40º F �t 7.5 (1692) 6.3 (1.9) UPS 26-99FC, 115V, Speed1 --

Flow limitation 14.3 GPM (3250 L/h)

Model B2HB 57 Flow rate

GPM (L/h)

Boiler pressure drop

ft. (m)

Recommended

pump option 1

Grundfos

Recommended

pump option 2

Grundfos

20º F �t --------

25º F �t --------30º F �t 12.3 (2801) 13.5 (4.1) UPS 26-99FC, 115V, Speed2 UP 26-64F, 115V35º F �t 10.6 (2401) 12.7 (3.9) UPS 26-99FC, 115V, Speed2 UP 26-64F, 115V40º F �t 9.3 (2101) 9.0 (2.7) UPS 26-99FC, 115V, Speed1 --Flow limitation 14.3 GPM (3250 L/h)

Pump Information

Vitodens 200-W, Technical Data

Page 26: Application Guide - Viessmann

22

Heating Circuit / Boiler PumpsViessmann offers a variety of Grundfos heating circuit / boiler pumps which meet typical Vitodens system installation requirements (see “Heating circuit pump (field supplied)” or “Boiler pump (field supplied)” in the Installation Examples starting on page 31). See tables below for recommended pumps. Refer to the graphs on page 9 for the proper waterside boiler friction loss calculations. The following pumps have been selected based on boiler heat exchanger head loss and boiler piping to a low-loss header.

IMPORTANT

Model B2HA 112 Flow rate Boiler pressure drop (ft.) Recommended pump Grundfos

20ºF �t 37.5 15.0 UPS 32-160/2, 115V, Speed 1 / UPS 26-150F, 115V, Speed 2

25ºF �t 30.0 11.3 UPS 32-160/2, 115V, Speed 1 / UPS 26-150F, 115V, Speed 2

30ºF �t 25.0 8.8 UPS 32-160/2, 115V, Speed 1 / UPS 26-150F, 115V, Speed 2

35ºF �t 21.4 6.5 UPS 32-160/2, 115V, Speed 1 / UPS 26-99FC, 115V, Speed 3

40ºF �t 19.5 4.8 UPS 26-99FC, 115V, Speed 2 / UPS 26-150F, 115V, Speed 1

Flow limitation )0068 ( 9.73)h/L( MPG

Model B2HA 150 Flow rate Boiler pressure drop (ft.) Recommended pump Grundfos

20ºF �t ------

25ºF �t ------

30ºF �t 33.0 12.6 UPS 32-160/2, 115V, Speed 1 / UPS 26-150F, 115V, Speed 3

35ºF �t 28.3 9.4 UPS 32-160/2, 115V, Speed 1 / UPS 26-150F, 115V, Speed 2

40ºF �t 24.8 8.0 UPS 26-99FC, 115V, Speed 3 / UPS 32-160/2, 115V, Speed 1 /

Flow limitation )h/L( MPG

Model B2HA 100 Flow rate Boiler pressure drop (ft.) Recommended pump Grundfos

20ºF �t ------

25ºF �t ------

30ºF �t 22.2 12.0 UPS 32-160/2, 115V, Speed 1 / UPS 26-99FC, 115V, Speed 3

35ºF �t 3 deepS ,V511 ,CF99-62 SPU5.80.91

40ºF �t 2 deepS ,V511 ,CF99-62 SPU0.67.61

Flow limitation )0075 ( 52)h/L( MPG

Before using the following pumps for a DHW tank application, find out the proper pressure drop through the tank, the required temperature difference through the coil and system piping head loss of the domestic hot water.

Pump selection must be based on accurate system flow

and pressure drop calculations (incl. DHW sizing).

Model B2HA 88 Flow rate Boiler pressure drop (ft.) Recommended pump Grundfos

20ºF �t ------

25ºF �t 23.5 11.2 UPS 26-99FC, 115V, Speed 3

30ºF �t 3 deepS ,V511 ,CF99-62 SPU5.96.91

35ºF �t 2 deepS ,V511 ,CF99-62 SPU5.58.61

40ºF �t 2 deepS ,V511 ,CF99-62 SPU5.47.41

Flow limitation )0075 ( 52)h/L( MPG

)0068 ( 9.73

Pump Information

Vitodens 200-W, Technical Data

Page 27: Application Guide - Viessmann

23

Boiler location

As a direct vent appliance, the Vitodens 200-W can be installed for room air independent operation (sealed combustion) regardless of size and ventilation method of the room in which it is located.The Vitodens 200-W can be installed, for example, in the main living area of a house, in non-ventilated utility rooms, cupboards, closets and alcoves with no clearance required from combustible materials, as well as in attics with a direct outlet for the flue gas/fresh air system. Follow all local and national codes.

Flue gas system

PPS (Polypropylene) concentric flue gas/fresh air systems for room air independent operation (sealed combustion) and side wall venting are tested to ANSI Z21.13 - CSA 4.9 - 2000 standards and are certified together with the Vitodens 200-W boiler as a constructional unit.The Vitodens 200-W boiler may also be vented vertically, using an AL29-4C® special stainless steel, single-wall, room air dependent venting system (UL listed for category IV).For a more detailed description of the direct vent and single-wall vent system, please refer to the Vitodens 200-W Venting System Installation Instructions.

Flue gas temperature protection

Flue pipes used for the Vitodens 200-W are suitable for max. flue gas temperatures of up to 230°F (110°C).No flue gas temperature protection is required as the maximum permissible flue gas temperature is not exceeded in any operating condition or in the event of malfunctioning.

Low water cut-off

A low water cut-off may be required by local codes. If the boiler is installed above the radiation level, a low water cut-off device of approved type must be installed in all instances. An approved type low water cut-off device must be provided by the heating contractor. Do not install an isolation valve between the boiler and the low water cut-off.

Water connections

Vitodens 200-W boilers can be used in any fully pumped hot water heating system.Minimum system pressure is 1 bar (14 psig).Chemical corrosion protection productsCorrosion does not typically occur in sealed heating systems which have been correctly installed and are correctly operated.Many manufacturers of plastic pipes recommend the use of chemical additives. In this case, only those commercially available corrosion protection products approved for boilers with domestic hot water heating via single-wall heat exchangers (instantaneous plate heat exchangers or DHW tanks) must be used.

Water quality

Treatment for boiler feed water should be considered in areas of known problems, such as where a high mineral content and hardness exist. In areas where freezing might occur, an antifreeze may be added to the system water to protect the system. Please adhere to the specifications given by the antifreeze manufacturer. Do not use automotive silicate based antifreeze. Please observe that an antifreeze/water mixture may require a backflow preventer within the automatic water feed and influence components such as diaphragm expansion tanks, radiation, etc. Maximum antifreeze content is 50% for the Vitodens 200-W boiler. Do not use antifreeze other than specifically made for hot water heating systems. System also may contain components which might be negatively affected by antifreeze. Check total system frequently when filled with antifreeze. Advise system operator/ultimate owner that system is filled with a glycol mix. The heating contractor must provide a MSDS (Material Safety Data Sheet) for the antifreeze used to the system operator/ultimate owner.

Total permissible hardness of the fill and top-up water

Total heating output Specific heating volume

UTB 2143 rep GSU 5<HBM 5USG per 3412 BTU to<13USG per 3412 BTU

13USG per 3412 BTU

170 300 ppm 17.5 gpg 200 ppm 11.7 gpg 2 ppm 0.11 gpg

> 170 to 682 200 ppm 11.7 gpg 150 ppm 8.8 gpg 2 ppm 0.11 gpg

> 682 to 170 150 ppm 8.8 gpg 2 ppm 0.11 gpg 2 ppm 0.11 gpg

> 2050 2 ppm 0.11 gpg 2 ppm 0.11 gpg 2 ppm 0.11 gpg

ppm - parts per milliongpg - grains per gallon

System Design Considerations

Vitodens 200-W, Technical Data

Page 28: Application Guide - Viessmann

24

Oxygen diffusion barrier underfloor tubing

The boiler warranty does not cover leaks resulting from corrosion caused by the use of underfloor plastic tubing without an oxygen diffusion barrier. Such systems must have the non-oxygen diffusion barrier tubing separated from the boiler with a heat exchanger. Viessmann recommends the use of underfloor plastic tubing with an oxygen diffusion barrier.

Warranty

Our warranty does not cover damages resulting from the following:- installation or service by unqualified and unlicensed personnel.- attempting to perform any repair work on the boiler other than that mentioned in the boiler literature.- tampering with or attempting, without Viessmann permission, to readjust the factory settings of the; -combination gas valve -combustion air opening of the burner blower - leaks resulting from corrosion caused by the use of underfloor plastic tubing without an oxygen diffusion barrier. For detailed warranty information, please read warranty sheet supplied with product.

System layout

� The max. boiler water temperature for space heating and DHW production is 165°F (74°C) for models B2HB 19 to 35. To minimize distribution losses, Viessmann recommends that the heating and domestic hot water systems be based on a maximum boiler supply temperature of 158°F (70°C).

� Due to the low return temperatures required for gas condensing, no mixing valves should be used in the heating circuit whenever possible. If mixing valves are required, e.g. for multi-circuit systems or underfloor heating systems, only 3-way mixing valves must be used. Do not use 4-way mixing valves with condensing boilers.

Underfloor heating systems

For underfloor heating systems Viessmann recommends the use of plastic tubing with an oxygen diffusion barrier in order to prevent the diffusion of oxygen through tubing. If plastic tubing without an oxygen diffusion barrier is used in underfloor heating systems, Viessmann recommends that such systems be separated from the boiler with a heat exchanger.Underfloor heating systems and heating circuits containing a very large volume of water must be connected to the boiler via a 3-way mixing valve; please refer to the applicable installation example in this manual.

Considerations

Vitodens 200-W, Technical Data

Page 29: Application Guide - Viessmann

25

Power

Pump

MixingModule

SupplySensor

Comm. BusOn Boiler

145145 2

17

5220

not used 40A

40

Notes/Comments

1. When multiple 145 communication accessories are being installed, 145 cables will need to be run from device to device. (Daisy Chain)

2. Ensure to set the S1 switch to assign the mixing valve heating circuit.

Product Information

Wiring a Mixing Valve Extension Module

Page 30: Application Guide - Viessmann

26

Zone Control Wizard Setup

Notes/Comments

1. Power Boiler ON

2. Setting of Time and Date

3. Press Menu+OK buttons to access Service Menu

4. Down Arrow to Service Functions

5. Press OK

6. Activate Yes/No

7. Arrow up to YES

8. Press OK

Sele

ct

nu

mb

er

of

ZC

cir

cu

its 1

, 2 o

r 3

System with 1 Zone Circuit

ZC

2 a

nd

ZC

3 C

on

fi g

ura

tio

n S

etu

p

Press OK at each

screen to enter

setting and move

to next step

Vitodens 200-W, Technical Data

Page 31: Application Guide - Viessmann

27

System with 2 Zone Circuits System with 3 Zone Circuits

OR OR

Operational Screen Information

ZC Weather Compensated Confi guredZC Fixed Setpoint Confi gured

User Interface Details:

1. Indication of ZC circuit boiler is confi gured for ZC1/ZC2/ZC3 use arrows left or right to select.

2. Display will show r when a ZC call is present and a p symbol if ZC1/ZC2/ZC3 are confi gured with an associated pump output.

3. Display of actual boiler water temperature.

4. Flame indication when burner ON and will show % of modulation.

5. Target temperature of zone. The Fixed Setpoint will show the set temperature during confi guration and Weather Compensated will show target based on slope and shift.

6. Outdoor temperature is shown when Weather Compensated ZC is confi gured.

1

2

3

56

56% 4

1

2

3

5

456%

Vitodens 200-W, Technical Data

Page 32: Application Guide - Viessmann

28

Not

es/C

omm

ents

1.

Hyd

raul

ical

ly s

epar

atin

g th

e fl o

w o

f th

e bo

iler

and

syst

em w

ith c

lose

ly s

pace

d te

es o

r a

low

loss

he

ader

, ens

ures

tha

t th

e bo

iler

and

syst

em fl

ows

do n

ot a

ffect

eac

h ot

her.

2.

Bec

ause

of

the

fl ow

res

tric

tion

thro

ugh

the

boile

r, it

is r

ecom

men

ded

to in

stal

l the

P1

circ

ulat

or o

n th

e re

turn

wat

er s

ide

of t

he b

oile

r.

3.

Ref

er t

o co

mpo

nent

inde

x on

Pag

e 5.

App

licat

ion

Cod

e

VD

2X 1

ZC1Z

P.01

Low

Los

s H

eade

rC

lose

ly S

pace

d Te

es

Vito

dens

200

-WA

pp

licati

on

1

P1

P1

P3

P3

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19 &

20

B2H

B 1

9-57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

Page 33: Application Guide - Viessmann

29

Vito

dens

200

-W

Ap

plicati

on

1

Ap

plic

atio

n C

od

e

VD

2X 1

ZC1Z

P.01

No

tes/

Co

mm

ents

Front of Boiler

Page 34: Application Guide - Viessmann

30

Zone Control Wizard Setup 1 Zone Circuit: Fixed Set Point OR Weather Compensated

Select the correct number of Zone Circuitconnections with respect to the number of thermostats connected to the DE connections.Press OK

Depending on how the zone temperature set point is determined, select either Fixed Setpoint or Weather Compensated. Adjustments to either setting will follow.

Select the desired pump output that will beenabled during a ZC call. When there is a call,the output will be energized for the duration of the call.

The zone circuit setting output summary shows the selected pumps depending on the number of zones selected in the very beginning.

The Start-up is fi nished and boiler is ready for operation.

Fixed Setpoint: Enter the value that is to be used by the boiler as a target water temperature when there is a call for heat.

Weather Compensated: The Slope and Shiftsettings can be adjusted to allow a heating curve to be set. When there is a zone heat demand, the calculated set point will be used as long as the demand is present.

This particular application represents a low mass boiler with a single system loop. Because the systemfl ow requirements may vary or fall outside of the parameters of the boiler's recommended fl ow, it is benefi cial to hydraulically separate the system fl ow from the boiler fl ow. This can be achieved by using a low loss header or closely spaced tees on the system loop. A low loss header sensor can be installed allowing better system control and increased effi ciency. A ZC1 thermostat call will be sensed by the EA1 module and turn on the confi gured 28/20 P3 pump providing the necessary fl ow. Depending on the ZC1 confi guration, it is possible to provide either a fi xed setpoint or a weather compensated control option.

Page 35: Application Guide - Viessmann

31

Application 1 - Operational Setup ... continued

Notes/Comments

Further Considerations

DHW Production

Set timer schedule as desired. If DHW production possible at any time, program timer settings to 0:00 to 24:00

DHW Recirculation Pump

Set recirculation pump timer as desired for pump connected to 28/20 output

DHW production from system side of low loss header, address 5B will need to be changed from a value of 0 to 1.

DHW priority can be removed by changing address A2 to a value of 0.

Boiler pump operation can be modifi ed with address 51 by setting to a value of 1. When there is a demand for heat, the boiler pump will turn on and then turn off after the demand has been removed and post purge time. This is based on having a low loss header temperature sensor installed.

The HC1 settings are still available should an outdoor reset based zone be connected. Should mixing valve extension kits be used, adjust the outdoor reset settings as required.

Page 36: Application Guide - Viessmann

32

App

licat

ion

Cod

e

VD

2I 1

ZC4Z

V.01

Not

es /

Com

men

ts

1.

P3

Zon

e pu

mp

pow

ered

by

157

outp

ut o

f E

A1

mod

ule

from

con

fi gur

atio

n of

Zon

e C

ircui

t 1.

2.

If a

sin

gle

spee

d ci

rcul

ator

is b

eing

util

ized

, a

pres

sure

diff

eren

tial b

ypas

s is

rec

omm

ende

d to

pr

even

t in

crea

sed

circ

ulat

ion

whe

n a

sing

le z

one

valv

e op

ens.

3.

A v

aria

ble

spee

d ci

rcul

ator

will

aut

omat

ical

ly a

djus

t to

ope

ning

and

clo

sing

zon

es. T

his

ensu

res

prop

er

fl ow

reg

ardl

ess

of h

ow m

any

zone

s ar

e op

en.

P1

Z1Z2

Z3Z4

P2

P3

P2.

1

Vito

dens

200

-WA

pp

licati

on

2

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

Page 37: Application Guide - Viessmann

33

Vito

dens

200-

WA

pp

licati

on

2

Not

es /

Com

men

ts

1. P

3 Z

one

pum

p po

wer

ed b

y 15

7 ou

tput

of

EA1

mod

ule

from

con

fi gur

atio

n of

Zon

e C

ircui

t 1.

2. D

on't

forg

et a

bout

the

jum

per b

etw

een

the

40A

and

the

157

Plug

(*).

App

licat

ion

Cod

e

VD

2I 1

ZC4Z

V.01

*

Low

loss

hea

der

sens

or(o

ptio

nal)

Front of Boiler

Page 38: Application Guide - Viessmann

34

In this system you have a Vitodens 200 with an indirect water heater and a four-zone single temperaturesystem. Upon a call for heat from one of the four zone thermostats, the respective zone valve will open. The end switch will provide a demand input DE1 of the EA1 module. The 157 plug connected P3 pump will turn on and the boiler will use the ZC set point to provide a target boiler water temperature. In the event there is a call for DHW, the P1 circulator will turn off and P2 will be engaged. This will provide a domestic priority function for the purpose of quickly satisfying a DHW demand. It is recommended to use a variable speed circulator for P3 that will adjust fl ow based on opening/closing zone valves. If a single speed pump is being used, ensure a pressure differential bypass is incorporated into the system to avoid “over pumping” a single circuit when a zone is calling for heat.

Zone Control Wizard Setup 1 Zone Circuit: Fixed Set Point with 157 Pump Output

Since this particular application is a single temperature circuit, select 1 Zone Circuit from the menu options.

This application is based on a Fixed Setpointtemperature during a zone call for heat. Press OKto confi rm selection.

Enter the value that is to be used by the boiler asa target water temperature where there is a callfor heat. You can adjust the values by arrowingdown or up to the correct set point value andpress OK.

The pump based on this application is controlledby the 157 output. Arrow down until 157 Outputis highlighted and press OK.

The zone circuit setting output summary showsthe selected pumps depending on the number of zones selected in the very beginning. Press OK to continue.

The Start-up is fi nished and boiler is ready for operation. Press OK to continue

Page 39: Application Guide - Viessmann

35

Application 2 - Operational Setup ... continued

Notes/Comments

Page 40: Application Guide - Viessmann

36

Ap

plic

atio

n C

od

e

VD

2I 1

ZC4Z

P.01

No

tes/

Co

mm

ents

1.

Ref

eren

ce c

ompo

nent

inde

x on

pag

e 5.

2.

Alw

ays

cons

ider

the

ele

ctric

al c

onsu

mpt

ion

asso

ciat

ed w

ith z

onin

g a

syst

em w

ith c

ircul

ator

s.

Oft

en t

here

are

mor

e ef

fi cie

nt a

ltern

ativ

es w

hich

co

uld

be c

onsi

dere

d w

hen

desi

gnin

g a

syst

em.

P1

P4

P5

P6

P2

P3

P2.1

Vito

dens

200

-WA

pp

licati

on

3

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

Page 41: Application Guide - Viessmann

37

120V

Pow

er

P2 P1 P2.1

Zone

1

Zone

2

Pow

er

Zone

3

Zone

4

P6 P5 P4 P3

Multizo

neCo

ntrol

DH

WSe

nsor

Out

door

Sens

or

Low

Los

sH

eade

rSe

nsor

(Opt

iona

l)

Vito

dens

200

-WA

pp

licati

on

3

Not

es /

Com

men

ts

1. T

here

are

no

confi

gur

ed p

umps

with

re

spec

t to

the

Zon

e C

ircui

t co

nfi g

urat

ion.

Pu

mps

are

con

trol

led

by t

he M

ultiz

one

Con

trol

.

App

licat

ion

Cod

e

VD

2I 1

ZC4Z

P.01

Low

loss

hea

der

sens

or(o

ptio

nal)

Connection Optional

Front of Boiler

Page 42: Application Guide - Viessmann

38

Zone Control Wizard Setup 1 Zone Circuit: Fixed Set Point w/no confi gured pump output

Vitodens 200-W

If you are zoning with pumps, consider this application for your next install. This system shows a Vitodens 200 with an indirect water heater and a four zone single temperature system. Upon a call for heat from a thermostat, the associated zone pump is energized by the multi-zone control. The connection of the heat demand output of the Multizone Control will provide a demand to the DE1 of the EA1 module generating a ZC1 set point demand. This is a very simple control solution for single temperature applications.

Since this particular application is a single temperature circuit, select 1 Zone Circuit from the menu options.

This application is based on a Fixed Setpointtemperature during a zone call for heat.Press OK to confi rm selection.

There is no assigned pump for this application.Pressing the OK button will not assign anyspecifi c pump output

The zone circuit summary indicates no pumps selected.

The Start-up is fi nished and boiler is ready for operation. Press OK to continue

Enter the value that is to be used by the boiler as a target water temperature where there is a call for heat. You can adjust the values by arrowingdown or up to the correct set point value andpress OK.

Page 43: Application Guide - Viessmann

39

Application 3 - Operational Setup ... continued

Notes/Comments

Further Considerations

DHW Production

Set timer schedule as desired. If DHW production possible at any time, program timer settings to 0:00 to 24:00

DHW Recirculation Pump

Set recirculation pump timer as desired for pump connected to 28/20 output

DHW production from system side of low loss header, address 5B will need to be changed from a value of 0 to 1.

DHW priority can be removed by changing address A2 to a value of 0.

Boiler pump operation can be modifi ed with address 51 by setting to a value of 1. When there is a demand for heat, the boiler pump will turn on and then turn off after the demand has been removed and post purge time. This is based on having a low loss header temperature sensor installed.

The HC1 settings are still available should an outdoor reset based zone be connected. Should mixing valve extension kits be used, adjust the outdoor reset settings as required.

Page 44: Application Guide - Viessmann

40

Vito

dens

200

-W

Ap

plicati

on

4

App

licat

ion

Cod

e

VD

2I 2

ZC2Z

P.01

Not

es /

Com

men

ts

1.

A t

herm

osta

tic m

ixin

g va

lve

shou

ld b

e in

stal

led

to p

rote

ct t

he r

adia

nt fl

oor

heat

ing

from

rec

eivi

ng

exce

ssiv

e ho

t w

ater

. (*s

how

n ab

ove)

2.

Com

pone

nt in

dex

on p

age

5.

*

ZC

1

ZC

2

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

P4

P3

P1

P2

Page 45: Application Guide - Viessmann

41

P2 P1

Pow

er

ZC2

P3ZC1

P4

����

����

��

Out

door

Sens

or

����

����

���

����

�Se

nsor

X11

Hea

t Dem

and

Cont

act

from

Air

Han

dler

Cont

act f

rom

inflo

orhe

at c

ontr

ol

(Opt

iona

l)

(Opt

iona

l)ZC

2

ZC1

App

licat

ion

Cod

e

VD

2I 2

ZC2Z

P.01

Vito

dens

200

-WA

pp

licati

on

4

Not

es /

Com

men

ts

1. H

eat

dem

and

cont

act

from

air

hand

ler

mus

t be

a d

ry c

onta

ct /

pote

ntia

l fre

e.

2. T

he d

ry c

onta

ct fo

r th

e ra

dian

t he

at

circ

uit

coul

d co

me

from

a d

evic

e su

ch a

s a

ther

mos

tat,

zon

e va

lve,

or

mul

ti zo

ne

cont

rolle

r.

3. D

on't

forg

et a

bout

the

jum

per

betw

een

the

40A

plu

g an

d th

e 15

7 P

lug.

(*)

4. I

f P

3 is

con

trol

led

by t

he a

ir ha

ndle

r, no

pu

mp

wiri

ng is

nec

essa

ry.

*Lo

w lo

ss h

eade

r se

nsor

(op

tiona

l)

Front of Boiler

Page 46: Application Guide - Viessmann

42

Zone Control Wizard—2 ZC—ZC1 Setpoint Demand with ZC2 Weather Compensated

Vitodens 200-W

This application features two heat circuits which operate at different temperatures. This particular drawing portrays ZC1 as a low temperature circuit and the air handler as a mid/high temperature circuit, ZC2. Although there are many different confi gurations, the setup below will operate ZC1 as an on/off function where an outdoor reset curve will be enabled during a thermostat call. The ZC2 air handler will operate on a constant temperature setpoint also referred to as a Fixed Setpoint. It is important to provide a method of protecting the ZC1 from high water temperatures when the air handler is operating, so don't forget to include the thermostatic mixing valve. The ZC1 shown here is confi gured with pump output 28/20 and the ZC2 call will bring on the 157 plug connected pump should there be a call for heat.

Select the correct number of Zone Circuitconnections with respect to the number ofthermostats connected to the DE connections.Press OK

This application is based on a WeatherCompensated, arrow down and press OK toconfi rm setting.

Once the settings have been made, press OK tocontinue. These settings can be easily adjustedlater on should they need to be changed.

The ZC1 pump for this particular application is the 28/20 pump. Pressing OK continues to the ZC2 circuit,

The Zone Circuit 2 is to be set for Fixed Setpointtemperature demand. Press OK to select andcontinue.The next screen allows for a set point adjustment of the zone target temperature

The fi nal step in this application confi guration isto select the associated pump for ZC2. Selectthe 157 Output and press OK.

Following will be the output summary and thestart up confi guration is fi nished

The Slope and Shift settings can be adjusted toallow a heating curve to be set. When there is azone heat demand, the calculated set point will beused as long as the demand is present. Arrow upor down to move to the shift setting from slope. Making an adjustment of either setting willgraphically indicate how the heating curve moves.

Page 47: Application Guide - Viessmann

43

Notes/Comments

Application 4 - Operational Setup ... continued

Page 48: Application Guide - Viessmann

44

Vito

dens

200

-W

P1

P2.1

P4

P2

P3

Ap

plicati

on

5

App

licat

ion

Cod

e

VD

2I 3

HC

/ZC

3ZP.

01

Not

es /

Com

men

ts

1.

A t

herm

osta

tic m

ixin

g va

lve

may

be

requ

ired

on t

he

radi

ator

loop

to

prev

ent

exce

ssiv

e ho

t w

ater

sup

ply

to

the

circ

uit

whe

n th

e D

HW

is c

allin

g fo

r he

at.

2.

Com

pone

nt In

dex

on p

ages

5.

3.

Whe

n th

e in

dire

ct D

HW

tan

k is

par

t of

the

sys

tem

lo

ad, c

onsi

dera

tion

mus

t be

giv

en t

o th

e si

ze o

f th

e bo

iler

in o

rder

to

allo

w fo

r si

mul

tane

ous

oper

atio

n of

sp

ace

heat

ing

and

DH

W.

Pres

sure

Dro

p / P

ump

Sizi

ng

Vito

dens

200

-W

1

9 &

20

B2H

B 1

9-57

Vito

dens

200

-W

2

1 &

22

B2H

A 8

0-15

0

HC

2Z

C1

Page

Page 49: Application Guide - Viessmann

45

P1Pow

er

P2.1

P3 ZC1

T-st

at (S

et P

oint

)

DH

WSe

nsor

Out

door

Sens

or

Low

Los

sH

eade

rSe

nsor

X11

HC2

Mix

ing

Valv

eM

odul

eSe

e pg

. 25

P4

(Opt

iona

l)

P2

Vito

dens

200

-WA

pp

licati

on

5

Not

es /

Com

men

ts

1.

For

mor

e in

form

atio

n re

gard

ing

the

wiri

ng

of t

he M

ixin

g Va

lve

Mod

ule,

see

pag

e 25

2.

Don

't fo

rget

abo

ut t

he ju

mpe

r be

twee

n th

e 40

A p

lug

and

the

157

Plu

g. (*

)

App

licat

ion

Cod

e

VD

2I 3

HC

/ZC

3ZP.

01

*

Low

loss

hea

der

sens

or(o

ptio

nal)

Front of Boiler

Page 50: Application Guide - Viessmann

46

Zone Control Wizard Setup 1 Zone Circuit: Fixed Set Point with 157 Pump Output

Vitodens 200-W

This application shows a low temperature heat circuit with 3-way mixing valve, a high temperature heating circuit ZC1 and an indirect DHW piped on the system side of the low loss header. This application allows for simultaneous operation of both space heating and DHW, just remember to size your boiler accordingly. A ZC1 call will turn on the confi gured 157 plug connected pump providing fl ow for the high temperature zone. The HC2 mixing valve will operate from heating curve settings, set within the boiler control.

Select the correct number of Zone Circuitconnections with respect to the number ofthermostats connected to the DE connections.Press OK

This application is based on a Fixed Setpointtemperature during a zone call for heat. Press OKto confi rm selection.

Enter the value that is to be used by the boiler asa target water temperature where there is a callfor heat. You can adjust the values by arrowingdown or up to the correct set point value andpress OK.

The pump based on this application is controlledby the 157 output. Arrow down until 157 Outputis highlighted and press OK.

The zone circuit setting output summary showsthe selected pumps depending on the number ofzones selected in the very beginning. Press OK tocontinue.

The Start-up is fi nished and boiler is ready foroperation. Press OK to continue

Page 51: Application Guide - Viessmann

47

Application 5 - Operational Setup ... continued

Notes/Comments

Further Considerations

DHW Production

Set timer schedule as desired. If DHW production possible at any time, program timer settings to 0:00 to 24:00

DHW Recirculation Pump

Set recirculation pump timer as desired for pump connected to 28/20 output

DHW production from system side of low loss header, address 5B will need to be changed from a value of 0 to 1.

DHW priority can be removed by changing address A2 to a value of 0.

Boiler pump operation can be modifi ed with address 51 by setting to a value of 1. When there is a demand for heat, the boiler pump will turn on and then turn off after the demand has been removed and post purge time. This is based on having a low loss header temperature sensor installed.

The HC1 settings are still available should an outdoor reset based zone be connected. Should mixing valve extension kits be used, adjust the outdoor reset settings as required.

Page 52: Application Guide - Viessmann

48

Vito

dens

200

-W

M1

P4

P1

P3

M2

P2

P2.

1P

5

Ap

plicati

on

6

App

licat

ion

Cod

e

VD

2I 3

HC

/ZC

3ZP.

02

Not

es /

Com

men

ts

1.

Com

pone

nt In

dex

on p

ages

5.

2.

Ext

erna

l fl o

w c

heck

val

ves

are

not

nece

ssar

y if

built

in

to t

he c

ircul

ator

s.

Pres

sure

Dro

p / P

ump

Sizi

ng

Vito

dens

200

-W

1

9 &

20

B2H

B 1

9-57

Vito

dens

200

-W

21 &

22

B2H

A 8

0-15

0

Page

HC

3H

C2

ZC

1

Page 53: Application Guide - Viessmann

49

HC2

Mix

ing

Valv

eM

odul

eSe

e pg

. 25

P2 P1Pow

er

P2.1

ZC1

P3 ZC1

T-st

at

����

����

��

Out

door

Sens

or

����

����

���

����

�Se

nsor

X11

P5P4

HC3

Mix

ing

Valv

eM

odul

eSe

e pg

. 25

(Opt

iona

l)

Vito

dens

200

-WA

pp

licati

on

6

Not

es /

Com

men

ts

1. J

umpe

r m

ust

be in

stal

led

betw

een

the

40A

pl

ug a

nd t

he 1

57 P

lug.

(*)

App

licat

ion

Cod

e

VD

2I 3

HC

/ZC

3ZP.

02

*

Low

loss

hea

der

sens

or(o

ptio

nal)

Front of Boiler

Page 54: Application Guide - Viessmann

50

Zone Control Wizard Setup 1 Zone Circuit: Fixed Set Point with 157 Pump Output

Vitodens 200-W

This application shows 2 heat circuits with mixing valves, a high temperature heat circuit, and an indirect DHW on the primary side of the low loss header. This system approach maximizes system effi ciency, control and comfort through precise water monitoring. The ZC1 thermostat call for heat will enable 157 plug to power the P3 pump providing fl ow in the unmixed temperature heating circuit. The ZC1 circuit can be confi gured to operate based on a Fixed Setpoint demand temperature or a Weather Compensated demand. The HC2 and HC3 mixing valve controls will operate based on heat curve settings from within the boiler.

Select the 1 Zone Circuit with respect to the ZC thermostat connected to the DE connections.Press OK

This application is based on a Fixed Setpointtemperature during a zone call for heat. Press OKto confi rm selection.

Enter the value that is to be used by the boiler asa target water temperature where there is a callfor heat. You can adjust the values by arrowingdown or up to the correct set point value andpress OK.

The pump based on this application is controlledby the 157 output. Arrow down until 157 Outputis highlighted and press OK.

The zone circuit setting output summary showsthe selected pumps depending on the number ofzones selected in the very beginning. Press OK tocontinue.

The Start-up is fi nished and boiler is ready foroperation. Press OK to continue

Page 55: Application Guide - Viessmann

51

Application 6 - Operational Setup ... continued

Notes/Comments

Page 56: Application Guide - Viessmann

52

Vito

dens

200

-W

P1

P3

ZC3

ZC2

P2

P2.

1

P5

Ap

plicati

on

7

App

licat

ion

Cod

e

VD

2I 3

ZC9C

.01

Not

es /

Com

men

ts

1.

Com

pone

nt In

dex

on p

ages

5.

2.

Ext

erna

l fl o

w c

heck

val

ves

are

not

nece

ssar

y if

built

in

to t

he c

ircul

ator

s.

Pres

sure

Dro

p / P

ump

Sizi

ng

Vito

dens

200

-W

1

9 &

20

B2H

B 1

9-57

Vito

dens

200

-W

21 &

22

B2H

A 8

0-15

0

Page

ZC1

Page 57: Application Guide - Viessmann

53

120V

Pow

er

P2 P1 P2.1

DH

WSe

nsor

Out

door

Sens

or

Low

Los

sH

eade

rSe

nsor

X11

ZC3

P5

Snow

Mel

tCo

ntro

l

T-St

at

��������

P3

120V

Pow

er

����

���

��

��

��

��

��

��

��

����

���

��

��

��

Mul

tizon

eCo

ntro

l ZC1

T-St

at

Mul

tizon

eCo

ntro

l ZC2

Menu

Item000 ZC

3

Vito

dens

200

-WA

pp

licati

on

7

Not

es /

Com

men

ts

1. J

umpe

r m

ust

be in

stal

led

betw

een

the

40A

pl

ug a

nd t

he 1

57 P

lug.

(*)

2. W

hen

ther

e ar

e de

man

d fo

r m

ultip

le

tem

pera

ture

s, t

he b

oile

r w

ill t

arge

t th

e hi

ghes

t of

the

the

req

uest

ed t

empe

ratu

res.

App

licat

ion

Cod

e

VD

2I 3

ZC9C

.01

*

Low

Los

sH

eade

rSe

nsor

(opt

iona

l)

DH

WSe

nsor

Front of Boiler

Page 58: Application Guide - Viessmann

54

Zone Control Wizard—3 ZC—ZC1 Setpoint Demand with ZC2 Weather Compensated

Vitodens 200-W

This application shows 3 heating circuits, where a combination of pumps, zone valves and two types of call for heat are utilized. The ZC1 demand input comes from a Multizone Control which is responsible for accepting thermostat calls where a respective pump is enabled. The ZC1 is also confi gured for a Weather Compensated function which allows a zone set point to be calculated based on the slope and shift settings. The ZC2 input from the second Mutlizone Control is confi gured for a Fixed Setpoint where there is a call. This Mutlizone Control is responsible for controlling 2 zone valves based on the 2 thermostats. Lastly, ZC3 input comes from a snow melt control. The ZC3 is also confi gured to provide pump control on the 157 plug output.

Select the correct number of Zone Circuit connectionswith respect to the number of controls connectedto the DE connections. Press OK

This application is based on a Weather Compensatedfor ZC1. Arrow down and press OK to confi rm setting.

The Slope and Shift settings can be adjusted to allow a heating curve to be set. When there is a zone heat demand, the calculated set point will be used as long as the demand is present. Arrow up or down to move to the shift setting from slope. Making an adjustment of either setting will graphically indicate how the heating curve moves.

Once the settings have been made, press OK to con-tinue. These settings can be easily adjusted later on should they need to be changed.

There is no pump associated with ZC1 for this particular application. OK continues to the ZC2 circuit.

The Zone Circuit 2 is to be set for Fixed Setpointtemperature demand. Press OK to select and continue.

The next screen allows for a set point adjustment ofthe zone target temperature

The Zone Circuit 3 as shown below is to be set forFixed Setpoint temperature demand. Press OK toselect and continue. The next screen allows for a setpoint adjustment of the zone target temperature andlastly the selection of the 157 pump output.

Page 59: Application Guide - Viessmann

55

Application 7 - Operational Setup Instructions... continued

Notes/Comments

Page 60: Application Guide - Viessmann

56

Vito

dens

200

-WA

pp

licati

on

8

P5

P1.1

P2

P4

P1.2

P2.1 App

licat

ion

Cod

e

2V

D2I

3H

C/Z

C3Z

P.01

Not

es /

Com

men

ts

1.

Com

pone

nt In

dex

on p

ages

5.

2.

Sin

ce t

he c

ircul

ator

in t

he a

ir ha

ndle

r is

not

co

ntro

lled

by t

he b

oile

r, hi

gher

tha

n de

sign

wat

er

tem

pera

ture

s m

ay r

each

the

air

hand

ler

whe

n th

e D

HW

is c

allin

g fo

r he

at.

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

HC

2E

xter

nal

Dem

and

Page 61: Application Guide - Viessmann

57

Not

es /

Com

men

ts

1. M

ax a

mp

load

of t

he c

asca

de c

ontr

ol is

6 a

mps

. Th

eref

ore,

if u

sing

mul

tiple

circ

ulat

ors

and

mix

ing

valv

e m

otor

s, is

olat

ion

rela

ys m

ay b

e re

quire

d.

2. P

5 is

inte

rnal

ly c

ontr

olle

d by

the

air

hand

ler.

3. S

troke

dire

ctio

n of

the

mix

ing

valv

e m

otor

sho

uld

be

verifi

ed

by a

n ac

tuat

or te

st. (

Ref

er to

the

Inst

alla

tion

& S

ervi

ce M

anua

l of t

he C

asca

de C

ontr

ol)

App

licat

ion

Cod

e

2VD

2I 3

HC

/ZC

3ZP.

01

P1.1

Pow

erP1

.2

Bo

ile

r #1

Bo

iler

#2

Pow

er

LON

Cabl

e

Vito

dens

200

-WA

pp

licati

on

8

Page 62: Application Guide - Viessmann

58

Not

es /

Com

men

ts

1. M

ax a

mp

load

of

the

casc

ade

cont

rol

is 6

am

ps. T

here

fore

, if

usin

g m

ultip

le

circ

ulat

ors

and

mix

ing

valv

e m

otor

s,

isol

atio

n re

lays

may

be

requ

ired.

2. P

5 is

inte

rnal

ly c

ontr

olle

d by

the

air

hand

ler.

3. S

trok

e di

rect

ion

of t

he m

ixin

g va

lve

mot

or

shou

ld b

e ve

rifi e

d by

an

actu

ator

tes

t.

(Ref

er t

o th

e In

stal

latio

n &

Ser

vice

Man

ual

of t

he C

asca

de C

ontr

ol)

App

licat

ion

Cod

e

2VD

2I 3

HC

/ZC

3ZP.

01

52

M

3

52

M

2

20

M3

20

M2

2

M3

2

M2

14

5

14

5

1

3/2

6

A

5

B

17

A

17

B

15

9

1

43

14

6

28

2

1

5

2 A

1/M

1

20

A1

2

9

5

0

40

1

56

52

M

3

52

M

2

20

M3

20

M2

2M

2

1

45

1

45

1

3

/2

5A

14

3

1

46

2

8

21

2

0 A

1

40

Out

door

Sens

or

Mix

ing

Valv

e Su

pply

Se

nsor

P4

LON

Cabl

e

Low

Los

s H

eade

r Se

nsor

DH

W

Sens

or

Mix

ing

Valv

e M

otor

Pow

erP2

P2.1

Air

Han

dler

H

eat

Dem

and

Vito

dens

200

-WA

pp

licati

on

8

Page 63: Application Guide - Viessmann

59

Application 8 Operational Setup Instructions

This application consists of a low temperature heat circuit with motorized mixing valve, a hot water forced air fan coil, indirect DHW and a 2-boiler cascade separated by a low loss header. This multi-boiler confi guration offers greater fl exibility in system design as it allows for increased system turndown, boiler redundancy, increased BTU inputs, and simultaneous operation of the heating and DHW. As the cascade control targets the maximum temperature for the system, the mixing valve offers the added benefi t of automatically adjusting the supply water temperature regardless of the water temperatures being supplied to the other heat circuits. Since this is all con-trolled by the cascade control, this makes for a simple, long lasting and effi cient system. To set up this system, follow the steps below:

Type/Option Step# Description Parameter Set to:Setup

Location

Setup on each boiler

1 Set to multi-boiler mode Service Function -> Select Multiboiler Application

Service Menu

2 Set boiler number 07: Set Boiler #

Set in Level 2 Coding

3 Set LON participant number 77: Set Boiler #

4 Disable VS pump control 30 :00

Setup On Cascade Control

5 Complete participant check (For further instruction, refer to Installation & Service Manual)

Service Menu

6 Select system type 00 :04Set in Level

2 Coding7 Set supply temperature of external demand 9B Set Temp.

8 Set up HC2 outdoor reset curve Set In Heating Sub

Menu9 Set DHW temperature

Optional Adjustments

Set a Heating ScheduleSet In

Heating Sub Menu

Set a DHW Schedule

Set a DHW Recirculation Schedule for P2.1

Vitodens 200-W

Notes/Comments

1. To enter service menu on the boiler you must hold the "OK" and buttons for 5 seconds.

2. Setup wizard for the boilers and cascade controls must be completed before proceeding with any additional confi gurations.

3. To enter the service level of the cascade control, press on the menu icon, select Service, and input the following password: viservice.

To proceed to level 2 coding, select system

confi guration icon, select coding 2 and input the following password: viexpert

Page 64: Application Guide - Viessmann

60

Ap

plic

atio

n C

od

e

2V

D2X

3H

C3Z

P.01

Vito

dens

200

-WA

pp

licati

on

9

M3

P5

P4

M2

P3

P6

P1.1

P1.2

Not

es /

Com

men

ts

1.

Com

pone

nt In

dex

on p

ages

5.

2.

Ext

erna

l fl o

w c

heck

val

ves

are

not

nece

ssar

y if

built

in

to t

he c

ircul

ator

s.

3.

Sin

ce H

C3

is s

epar

ated

fro

m t

he s

yste

m v

ia a

hea

t ex

chan

ger,

an a

utom

atic

fl ui

d fe

eder

may

be

desi

red.

4.

Bas

ed o

n re

com

men

ded

pipi

ng p

ract

ices

, a p

ress

ure

relie

f va

lve

shou

ld b

e in

stal

led

on t

he s

econ

dary

sid

e of

the

hea

t ex

chan

ger.*

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

HC

2H

C3

HC

1

*

Page 65: Application Guide - Viessmann

61

Not

es /

Com

men

ts

1. M

ax a

mp

load

of t

he c

asca

de c

ontr

ol is

6 a

mps

. Th

eref

ore,

if u

sing

mul

tiple

circ

ulat

ors

and

mix

ing

valv

e m

otor

s, is

olat

ion

rela

ys m

ay b

e re

quire

d.

2. S

trok

e di

rect

ion

of th

e m

ixin

g va

lve

mot

ors

shou

ld b

e ve

rifi e

d by

an

actu

ator

test

. Ref

er

to th

e In

stal

latio

n an

d Se

rvic

e M

anua

l of t

he

Cas

cade

Con

trol

.

App

licat

ion

Cod

e

2VD

2X 3

HC

3ZP.

01

P1.1

Pow

erP1

.2

Bo

ile

r #1

Bo

iler

#2

Pow

er

LON

Cabl

e

Vito

dens

200

-WA

pp

licati

on

9

Page 66: Application Guide - Viessmann

62

Not

es /

Com

men

ts

1. M

ax a

mp

load

of

the

casc

ade

cont

rol

is 6

am

ps. T

here

fore

, if

usin

g m

ultip

le

circ

ulat

ors

and

mix

ing

valv

e m

otor

s,

isol

atio

n re

lays

may

be

requ

ired.

2. S

trok

e di

rect

ion

of t

he m

ixin

g va

lve

mot

ors

shou

ld b

e ve

rifi e

d by

an

actu

ator

te

st. R

efer

to

the

Inst

alla

tion

and

Ser

vice

M

anua

l of

the

Cas

cade

Con

trol

.

App

licat

ion

Cod

e

2VD

2X 3

HC

3ZP.

01

Out

door

Sens

or(T

erm

inal

s 1&

2)

M3

Mix

ing

Supp

ly

Sens

or

P4

LON

Cabl

e

Low

Los

s H

eade

r Se

nsor

M2

Valv

e M

otor

Pow

er

5A

13/2

5A

M2

Mix

ing

Supp

ly

Sens

or

M3

Valv

e M

otor

P6P3

P5

34

HC1

T-S

tat t

o 14

3 Pl

ug

(Ter

min

als

1 &

2)

143

52

M

3

52

M

2

20

M3

20

M2

2

M3

2

M2

14

5

14

5

1

3/2

5

A

5

B

17

A

17

B

15

9

1

43

14

6

28

2

1

5

2 A

1/M

1

20

A1

2

9

5

0

40

1

56

52

M

3

52

M

2

20 M

3

2

0M

2

2

M2

2

M2

14

5

14

5

1

3/2

14

3

14

6

28

2

1

2

0A

1

40

Vito

dens

200

-WA

pp

licati

on

9

Page 67: Application Guide - Viessmann

63

Application 9 Operational Setup Instructions

This application consists of a mid-temperature heat circuit, a low temperature heat circuit with motorized mixing valve, and a low temperature heat circuit with heat exchanger and mixing valve. This application is conducive to systems in which glycol must be incorporated for safety purposes. This multi-boiler confi guration offers greater fl exibility in system design as it allows for increased system turndown, boiler redundancy, increased BTU inputs, and simultaneous operation of the heating and DHW. As the cascade control targets the maximum temperature for the system, the mixing valves offer the added benefi t of automatically adjusting the supply water temperature regardless of the water temperatures being supplied to the other heat circuits. Since this is all controlled by the cascade control, this makes for a simple, long lasting and effi cient system. To set up this system, follow the steps below:

Type/Option Step# Description Parameter Set to:Setup

Location

Setup on each boiler

1 Set to multi-boiler mode Service Function -> Select Multiboiler Application

Service Menu

2 Set boiler number 07: Set Boiler #

Set in Level 2 Coding

3 Set LON participant number 77: Set Boiler #

4 Disable VS pump control 30 :00

Setup On Cascade Control

5 Complete participant check (For further instruction, refer to Installation & Service Manual)

Service Menu

6 Assign thermostat to HC1 91 :01Set in Level

2 Coding7 Remove pump post purge F2 :00

8 Setup HC1 outdoor reset curve

Set In Heating Sub

Menu

9 Setup HC2 outdoor reset curve

10 Setup HC3 outdoor reset curve

11 Adjust HC1 heating schedule --:--Optional Adjustments

Set a Heating ScheduleSet In

Heating Sub Menu

Set a DHW Schedule

Set a DHW Recirculation Schedule for P2.1

Vitodens 200-W

Notes/Comments

1. To enter service menu on the boiler you must hold the "OK" and buttons for 5 seconds.

2. Setup wizard for the boilers and cascade controls must be completed before proceeding with any additional confi gurations.

3. To enter the service level of the cascade control, press on the menu icon, select Service, and input the following password: viservice

To proceed to level 2 coding, select system confi guration icon, select coding 2 and input the following password: viexpert

Page 68: Application Guide - Viessmann

64

Vito

dens

200

-WA

pp

licati

on

10

P2

P3

P2.1

P1.1

P1.2

P1.3

P1.4

Ap

plic

atio

n C

od

e

4V

D2I

2H

C2Z

P.01

Not

es /

Com

men

ts

1.

Com

pone

nt In

dex

on p

ages

5.

2.

Ext

erna

l fl o

w c

heck

val

ves

are

not

nece

ssar

y if

inte

grat

ed in

to t

he c

ircul

ator

s.

Pres

sure

Dro

p / P

ump

Sizi

ng

Page

Vito

dens

200

-W

19

& 2

0B

2HB

19-

57

Vito

dens

200

-W

21

& 2

2B

2HA

80-

150

Page 69: Application Guide - Viessmann

65

Not

es /

Com

men

ts

1. M

ax a

mp

load

of

the

casc

ade

cont

rol

is 6

am

ps. T

here

fore

, iso

latio

n re

lays

m

ay b

e re

quire

d w

hen

curr

ent

draw

of

fi el

d su

pplie

d co

mpo

nent

s is

ex

ceed

ed.

App

licat

ion

Cod

e

4VD

2I 2

HC

2ZP.

01

����

����

����

��

��

Bo

iler

#1B

oile

r #2

Bo

iler

#3B

oile

r #4

P1.

1

P

ow

erP

1.2

Po

wer

P1.

3

P

ow

erP

1.4

Po

wer

LON

Cabl

eLO

N Ca

ble

LON

Cabl

eLO

N Ca

ble

Vito

dens

200

-WA

pp

licati

on

10

Page 70: Application Guide - Viessmann

66

Not

es /

Com

men

ts

1.

Max

am

p lo

ad o

f th

e ca

scad

e co

ntro

l is

6 am

ps. T

here

fore

, iso

latio

n re

lays

may

be

requ

ired

whe

n cu

rren

t dr

aw o

f fi e

ld s

uppl

ied

com

pone

nts

is e

xcee

ded.

App

licat

ion

Cod

e

4VD

2I 2

HC

2ZP.

01

���

���

52

M

3

52

M

2

20

M3

20

M2

2

M3

2

M2

14

5

14

5

1

3/2

5

A

5

B

17

A

17

B

15

9

1

43

14

6

28

21

5

2 A

1/M

1

20

A1

2

9

5

0

40

1

56

1

45

1

45

1

3

/2

5A

1

43

14

6

28

2

1

2

0A

1

40

P2.

1P

2P

3

Po

wer

LON

Cabl

e

Out

door

Sens

or

Low

Los

s H

eade

r Se

nsor

DH

W

Sens

or

Vito

dens

200

-WA

pp

licati

on

10

Page 71: Application Guide - Viessmann

67

Application 10 Operational Setup Instructions

This application consists of a 4-boiler cascade, a single building loop and an indirect DHW. Designing a system in this way allows constant circulation of heated fl uid throughout larger commercial buildings. This provides the ability to have unit specifi c heat emitters and controls to maximize the comfort within the building. The P3 circulator operates continuously until the outdoor temperature exceeds the warm weather shut down, at which time the boiler and circulators will all enter into a standby mode until the outdoor temperature drops or there is a demand for DHW. To set up this system, follow the steps below:

Type/Option Step# Description Parameter Set to:Setup

Location

Setup on each boiler

1 Set to multi-boiler mode Service Function -> Select Multiboiler Application

Service Menu

2 Set boiler number 07: Set Boiler #

Set in Level 2 Coding

3 Set LON participant number 77: Set Boiler #

4 Disable VS pump control 30 :00

Setup On Cascade Control

5 Complete participant check (For further instruction, refer to Installation & Service Manual)

Service Menu

8 Setup HC1 outdoor reset curveSet In

Heating Sub Menu

9 Set DHW temperature

11 Adjust HC1 heating schedule --:--Optional Adjustments

Set a Heating ScheduleSet In

Heating Sub Menu

Set a DHW Schedule

Set a DHW Recirculation Schedule for P2.1

Vitodens 200-W

Notes/Comments

1. To enter service menu on the boiler you must hold the "OK" and buttons for 5 seconds.

2. Setup wizard for the boilers and cascade controls must be completed before proceeding with any additional confi gurations.

3. To enter the service level of the cascade control, press on the menu icon, select Service, and input the following password: viservice

To proceed to level 2 coding, select system confi guration icon, select coding 2 and input the following password: viexpert

Page 72: Application Guide - Viessmann

68

Vito

dens

200

-W

Wh

at

is a

Mic

rolo

ad

?

A M

icro

load

is ty

pica

lly c

onsi

dere

d a

zone

that

has

an

outp

ut s

ubst

antia

lly

less

than

the

boile

rs lo

wes

t fi ri

ng ra

te.

Even

whe

n fi r

ing

at it

s lo

wes

t inp

ut,

the

boile

r will

shor

t cyc

le p

uttin

g ad

d-ed

str

ess

on a

ll th

e co

mpo

nent

s an

d de

crea

sing

effi

cien

cy.

Mic

rolo

ad

Ap

plic

atio

n C

od

e

M

icro

load

No

tes/

Co

mm

ents

1. C

ompo

nent

Inde

x on

pag

es 5

.

2. T

o en

sure

cor

rect

ope

ratio

n, in

stal

l fl o

w c

heck

val

ves

acco

rdin

g to

thi

s di

agra

m

Page 73: Application Guide - Viessmann

69

So

luti

on

Pipi

ng a

“M

icro

load

” in

this

man

ner,

pre-

vent

s th

e bo

iler f

rom

sho

rt c

yclin

g. U

pon

a ca

ll fo

r hea

t, th

e ci

rcul

ator

sta

rts

up a

nd

draw

s he

at o

ut o

f the

indi

rect

wat

er h

eate

r. A

s th

e te

mpe

ratu

re in

the

wat

er h

eate

r de

crea

ses,

the

boile

r sen

ses

this

dro

p in

te

mpe

ratu

re a

nd p

roce

eds

to h

eat t

he ta

nk

back

up.

Bec

ause

of t

he la

rger

vol

ume

of

wat

er, t

his

exte

nds

the

boile

rs ru

n cy

cle

and

allo

ws

it to

ope

rate

at a

mor

e ef

fi cie

nt s

tate

.

Vito

dens

200

Mic

rolo

ad

Ap

plic

atio

n C

od

e

M

icro

load

Page 74: Application Guide - Viessmann

70

Application Rules & Formulas

Universal Hydronics Formula:

GPM=BTUH

500 x �TBTUH= GPM x 500 x �T

Quick Pipe Resistance Calculation:

1. Measure longest run of pipe 2. Add 50% for fi ttings 3. Multiply by .04= A rough calculation on the feet of head the pump needs to overcome for that circuit.

Piping & Tubing Properties

Steel/Wrought Iron Pipe

Pex Tubing

Copper Tubing (Type L)

*Based on a velocity of 4fpm*Based on 20°F �T

*Based on a velocity of 4fpm*Based on 20°F �T

*Based on a velocity of 4fpm*Based on 20°F �T

SizeContent/ft

(gal)

Max Flow Rate1

(GPM)

Max Heat Carrying

Capability (BTUH)2

1/2" .016 4 40,000

3/4" .028 7 70,000

1" .045 12 120,000

1-1/4" .078 20 200,000

1-1/2" .106 28 280,000

2" .174 44 440,000

SizeContent/ft

(gal)

Max Flow Rate1

(GPM)

Max Heat Carrying

Capability (BTUH)2

1/2" .009 2.3 23,000

5/8" .013 3.3 33,000

3/4" .018 4.6 46,000

1" .030 7.5 75,000

1-1/4" .046 11.2 112,000

1-1/2" .105 15.6 156,000

SizeContent/ft

(gal)

Max Flow Rate1

(GPM)

Max Heat Carrying

Capability (BTUH)2

3/8" .007 2 20,000

1/2" .012 3.2 32,000

3/4" .025 6.5 65,000

1" .043 10.9 109,000

1-1/4" .065 16.3 163,000

1-1/2" .092 22.9 229,000

2" .161 39.6 396,000

Page 75: Application Guide - Viessmann

71

Radiant Sizing:

Expansion Tank Quick Sizer

Buffer Tank Sizing

Pool Sizing

Pool Capacity (gallons): Circular Pool = Avg. Depth x Diameter2 x 5.9 Rectangular Pool = Avg. Depth x Length x Width x 7.5

BTUH Requirement:

Estimating Radiant Tubing6" OC Qty = FT2 of space x 212" OC Qty = FT2 of space x 1.2

Estimating BTUH for RadiantFloor Warming = 15-20 btuh/ftFloor Heating = 35-50 btuh/ft

Minimum Tank = Boiler Run Time x (Min Boiler Firing Rate - Smallest Zone) Volume = 500 x �T

Boiler OutputFinned

Baseboard

Air Handler/

Unit Heater

Cast

Radiator

Cast Iron

Baseboard

25,000 15 15 15 15

50,000 15 15 30 30

75,000 30 30 30 60

100,000 30 30 60 60

125,000 30 60 60 90

150,000 30 60 90 90

175,000 60 60 30V 30V

200,000 60 90 30V 30V

250,000 60 90 30V 40V

300,000 90 30V 30V 40V

Temp. Difference

between pool temp and

ambient air temp (°F)

10° 15° 20° 25° 30°

BTUH/Ft2 105 158 210 263 368

BTUH =Pool Capacity x 8.34 x Temp Rise

Hours to Heat Pool

Page 76: Application Guide - Viessmann

72

This is Viessmann

The Viessmann Group is one of the world’s leading manufacturers of heating and renewable energy systems. Family-owned since 1917, Prof. Dr. Martin Viessmann leads the company in its third generation. The group today employs over 11,400 employees worldwide and has a turnover of approx. 2.1 billion Euro. 27 manufacturing facilities in 11 countries, sales & distribution facilities in Germany and 74 other countries, and 120 sales offices worldwide provide customer proximity and a strong global presence. For three gen-erations, Viessmann has been providing comfortable, efficient and environmen-tally-responsible heating solutions, tai-lored to the needs of the market. With ongoing research and development and a focus on product innovation, Viess-mann has pioneered technologies that have continuously set standards and made the company into a technological innovator and pacesetter of the entire industry.

With the current comprehensive product range, Viessmann is offering a multi-level program of high-tech, state-of-the-art heating products. Wall-mounted gas-fired condensing boilers, floor-standing oil – or gas-fired hot water heating boilers, solar thermal systems, control technology

and DHW storage tanks – all designed to achieve superior performance, reliability and energy savings.

Accountability for the environment and society, fairness when dealing with business partners as well as the pursuit of perfection and maximum efficiency in all business transactions are key values for Viessmann – as a company, and as individuals. This, together with the products and services we offer, allows us to offer our customers the benefit and added value of a strong brand.

Viessmann Manufacturing Company Inc.

750 McMurray Rd.

Waterloo, ON N2V 2G5, Canada

1-800-387-7373

[email protected]

www.viessmann.ca

Viessmann Manufacturing Company Inc.

6350 204th St.

Langley, BC V2Y 2V1, Canada

1-877-853-3288

[email protected]

www.viessmann.ca

Viessmann Manufacturing Company Inc. USA

45 Access Rd.

Warwick, RI 02886, USA

1-800-288-0667

[email protected]

www.viessmann.com

Page 77: Application Guide - Viessmann

73

Global presence, local commitment.

Page 78: Application Guide - Viessmann
Page 79: Application Guide - Viessmann
Page 80: Application Guide - Viessmann

Viessmann Manufacturing Company Inc. Waterloo, ON Canada 1-800-387-7373 www.viessmann.ca

Viessmann Manufacturing Company Inc. USA Warwick, RI 02886, USA 1-800-288-0667 [email protected] www.viessmann.com

Technical information subject to change without notice. Printed in Canada 5777 143 - 04 02/2020