Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi...
Transcript of Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi...
![Page 1: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/1.jpg)
Appendix ALab Floor Plan
1Foot
A
21'4"
10'7''
Refrig.
A - 100psi Pressure Outlet + dry filterelectrical outlets 120vdimmer switch with LED LightingComputer LAN drop
Shelving (1ft)
A
Sheath Bag Hooks
v.150306
Lam
inar
H
ood
(BS
C II
)
keyed Access Pad
Rm.5613
Rm.5613-B
Rm.5609
Rm.5613-A
Glass wall / covered by dry wall
Ball-in-the-wall®
![Page 2: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/2.jpg)
Appendix BFlow Lab Warning
(Active and Inactive Sort)
Caution(:(Potentially(Dangerous(Aerosol(Exposure(DO(NOT(ENTER(IF(SORTING(IS(ACTIVE(
Authorized(Personnel(ONLY(Flow(Cytometry(Core(Cell(Sorting(Facility
Active(Sort
Caution(:(Potentially(Dangerous(Aerosol(Exposure(DO(NOT(ENTER(IF(SORTING(IS(ACTIVE(
Authorized(Personnel(ONLY(Flow(Cytometry(Core(Cell(Sorting(Facility
Inactive(Sort
![Page 3: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/3.jpg)
Appendix CAerosol System Flow
Vacuum Ports
Negative Pressure Flow
Vacuum Gauge
Pump Monitor
HEPA Filter and Vacuum Pump
Aerosol Management System
![Page 4: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/4.jpg)
Appendix DSort Chamber Modes
Standby mode Active mode
![Page 5: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/5.jpg)
Appendix ECyClex-d Device
Location
![Page 6: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/6.jpg)
Appendix FCyclex-d Device
![Page 7: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/7.jpg)
Figure A
Figure B
Appendix GDragon Green Particles
0 102 103 104 105B515-A
0
102
103
104
105
SSC
-A
0 102 103 104 105B515-A
0
2000
4000
6000
8000
10K
# C
ells
Dragon Green Beads
![Page 8: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/8.jpg)
Appendix HSalt Crystals on a Collection
Slide with Dragon Green Beads
![Page 9: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/9.jpg)
Appendix IAerosol Containment
Report
![Page 10: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/10.jpg)
Appendix JSheath Filter
A
C
B
![Page 11: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/11.jpg)
Appendix KPAPR system
Tyvek Body Suit
HEPA Shroud
Double Gloves
AirMAX HEPA filter PAPR
Helmet
Battery Light Level
Suit Boots
Suit Face Shield
Battery Pack
![Page 12: Appendix A 21'4 Lab Floor Plan A · A 21'4" 10'7'' Refrig. electrical outlets 120v A - 100psi Pressure Outlet + dry filter dimmer switch with LED Lighting Computer LAN drop Shelving](https://reader036.fdocuments.us/reader036/viewer/2022071017/5fd0fce3f26baa1ecd2c9b89/html5/thumbnails/12.jpg)
Appendix LRecord and Checklist