Adjustable thermostatic mixing valve
Duco Mix Duco T-Mix
All thermostatic mixing valves are available as solar models.
2
valve cover
spindlemix - out
control element
control valvePTFE
stainless steel spring
mixing ring
ZR brass body
in - cold
in - hot
DUCO thermostatic mixing valves are used in hot-water units for sanitary facilities. They are mounted in between the hot-water appliance (central heating boiler/storage tank) and the taps of the sanitary facilities. The aim is to keep the mixing water used at the draw-off points at a constant, pre-set temperature. That is because the temperature of the mixing water is subject to fluctuations in temperature and the pressure of inflowing cold and hot water.
DUCO thermostatic mixing valves can also be used in solar energy systems.
The sanitary water in such systems is usually hotter (up to approx. 95°C) coming from the storage tank of the solar energy system.
The internal components in this DUCO Solar Mix have been designed to guarantee the operation of the mixing valve at continuous use at a high temperature, up to 100°C.
Application Duco Mix and T-Mix mixing valve
Operation The thermostatic mixing valve has a control element that works like a temperature sensor. Through expansion and contraction, this sensor continuously controls the flow of hot and cold water in the right proportion. Even in the event of a drop in pressure, e.g. when others are drawing off water or after fluctuations in temperature at the cold and/or hot inlet of the valve, the valve will automatically control the water flow. In this way, the set temperature will be maintained.
Adjust the turning knob on top of the valve to set the temperature of the mixing water. The temperature of the sanitary hot water can be set between 30°C and 70°C.
Materials: •brassbodyfreeofdezincificationCW602N
•stainlesssteelspring •EPDMsealing •PPScontrolvalve(Ryton) •coatingsolarmodel:PTFESetting range: 30 - 70˚CAccuracy: approx. 2˚CMax. working pressure: 14 barMin. working pressure: 0.2 barMax. supply temperature: 85˚C / Solar 100˚CConnections: •15mmcompression •22mmcompression •22-28mmsolder •¾" •1"G •withnon-returnvalves:15mm
compression
Technical info
The expansion of the control element will push the control valve down against the operation of the spring. This will narrow the passage for hot water and simultaneously widen the passage for cold water.
The two water flows will merge in the control valve and intensively mix around the entire surface of the control element. This will cause the control element to immediately respond to any changes in temperature.
3
centralheating boiler
boiler/storage tank
collector (solar panel)
DUCO reversing valve (diverter) 15 mm
DUCO mixing valve 15 mm
outlet
inlet
Safety (risk of legionella and burns)
Hot water for sanitary use and units for storage of hot water (storage tank) must be kept at a temperature of 65°C or higher in order to control any growth of legionella bacteria. However, such water is too hot for immediate use (risks of burning the skin). A thermostatic mixing valve will reduce the temperature down to a pleasant, safe and constant level. Even in case of fluctuations in pressure and inlet temperature.
Sustainable (anti calcium)ThesolarmodelhasaPTFEcoating topreventcalcium deposits, thus ensuring a long life and reliable operation.
Reversing valve / diverter
Non-return valves (KIWA)Non-return valves are fitted inside the unit to prevent any unwanted flows/circulation of water. DUCO mixing valves are also available with integrated non-return valves (KIWA) in the cold and hot water inlets of the valve.
The reversing valve is to be mounted between the storage tank and the central heating boiler. If the storage tank is able to provide a sufficient amount of hot water, the reversing valve will lead the water directly to the mixing valve (instantaneous hot-water principle).
If the storage tank is no longer able to provide a sufficient amount of hot water, the reversing valve will lead the water to the central heating boiler (3 = in, 2 = out) for reheating.
Energy savingThe mixing valve is energy saving: a quick response to fluctuations in temperature and pressure, as well as limiting the temperature, will prevent the waste of energy.
Graph
4
Models
DUCO T-mix 22 compressionDUCO T-mix 22/28 solder
DUCO T-mix 3/4”DUCO T-mix 1”G
DUCO mix 15 compression incl. non-return valves (2x)
DUCO T-mix 15 compression incl. non-return valves (2x)
DUCO mix 15 compression
All models are also available as solar models
5
68,5
155
+4
64,5
+2
170 +2
64,5
88
28
weight = ±770 grams
NAME:
debur and
edges
roughness
Material:
date sign
Treatment
break sharp
:
year
PenTecThe Netherlands Druk- en temperatuurcomponenten pagespage
order
remarksdimension indicators
DRAWING NO:
scale:
01-10 F. Snel ( )weight
2009
1
1350-0-50-01
(...) reference #...# very important [...] theretical
projection
A4
T-Mix 28 soldeer
1:2 1
General tolerance R + 0,2mmGeneral tolerance ± 0,2mm 770 gr.
Angel tolerance ±0,5°3,26,4 1,6
C
2 31 4
B
A
D
E
F
revision:
All
righ
ts re
serv
ed
. Th
is d
raw
ing
is p
rop
ert
y o
f Pe
nTe
c B
.V. a
nd
sh
all
ne
ithe
r be
mu
ltip
lied
by
an
y m
ea
ns
no
r be
sh
ow
n t
o, o
r use
d b
y, t
hird
pa
rtie
s, w
itho
ut
writ
ten
pe
rmiiio
n o
f Pe
nTe
c B
.V.
tolerance
PenTec B.V.Haastrecht-HollandPostbus 1183420 DC Oudewater
Dimensions
DUCO T-mix 22 compression
DUCO T-mix 3/4"
DUCO mix 15 compressionDUCO mix 15 compression incl. non-return valves (2x)
DUCO T-mix 22/28 solder
DUCO T-mix 15 compression incl. non-return valves (2x)
APPE
NDAG
ES
Safety by PenTec
PenTecSnelrewaardbvProvincialewegOost34a2851AEHAASTRECHTThe Netherlands
Tel. +31 182 50 31 00 E-mail [email protected] www.pentecbv.nl