API PLAN 62 Installation of steam traps in steam quench
The object of this technical note is to draw
attention to a design of one of the most
commonly used API Plan, the Plan 62. This
document is focused on steam quench
applications, where there are possible
cases of typical arrangement that may
generate some confusion.
eading these lines, you may thin! that
the case and solution proposed herein are
ob"ious, and indeed they are. #owe"er,
the design discussed below is present at
many facilities, commercial document$
tation, projects, etc.
What does API 682 say about this Plan?
Source: API 682 4thEdition (Figure !24"
-
7/25/2019 API PLAN 62_Installation of Steam Traps in Steam Quench
2/3
urfing through the internet, it is easy to
find some documents, images and other
documentation with a particular
installation for the steam trap.
The following pictures shown the steam
trap assembled in the same pipe which
pro"ides the quench to the mechanical
seal )in$line. As the steam trap pre"ents
the passage of steam through it, only
condensate, and not steam, will reach to
the seal.
#et$s see so'e e,a'les:
I'ages o- .API Plan 62 stea' /uench0 1 -ro'di--erent sources -ound through oogle I'ages!
-
7/25/2019 API PLAN 62_Installation of Steam Traps in Steam Quench
3/3
I'ages o- .API Plan 62 stea' /uench0 1 endor
3ra&ings!
onclusion:
The conclusion can be summed up in a
simple sentence( /Install the steam trap
properly0.
Therefore, if the steam trap installation isas indicated in the e1amples, the steam
will not reach the mechanical seal. The
Plan will not meet its purpose and its
effecti"e pre"ention of co!e built up,
solids deposit, crystalliation, polymer$
riation, etc.
Additionally if the condensate is
introduced in the mechanical seal and
contact the seal faces, it can be
responsible of early seal failures.
ecommendations(
3. team trap shall be installed in a
branch line. 4epending on piping seal
plan arrangement the installation can
be as indicated in the s!etch bellow.
2. team trap shall be located as close
as possible to seal in the lowest
location.
5. It shall be agreed with end user
where steam trap outlet is
discharged and its configuration.
API Plan 62&ith stea' /uench
ose &uis Ayala arabia,
otating 7quipment 7ngineer at Tecnicas eunidas .A.
8onalo 9arrasco 8utierre,
:echanical 7ngineer at abic