Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI...

26
CORPORATION AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF Apache Corporation is one of the world's top independent oil and gas companies with exploration and production interests in the United States, Gulf of Mexico, Canada, Egypt, Australia, North Sea, Argentina and Chile. Our mission is to grow a profitable company for the long-term benefit of our shareholders by building a portfolio of core areas which provide long-term growth opportunities. Apaches’ strategy includes constructing a balanced portfolio of assets and maintaining financial flexibility, while maximizing earnings and cash flows by controlling costs. Algunos ejemplos Precuyo-Basamento en AND S. Lopez-V. Sissini-L Rodriguez-M. Lavia-G.Borges-S.Vargas Setiembre 2010 Apache Energía Argentina

Transcript of Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI...

Page 1: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

C O R P O R A T I O N

A U S T R A L I A A R G E N T I N A C A N A D A E G Y P T N O R T H S E A U . S . C E N T R A L U . S . G U L F

Apache Corporation is one of the world's top independent oil and gas companies with exploration and production interests in the United States, Gulf of Mexico,Canada, Egypt, Australia, North Sea, Argentina and Chile. Our mission is to grow a profitable company for the long-term benefit of our shareholders by building aportfolio of core areas which provide long-term growth opportunities. Apaches’ strategy includes constructing a balanced portfolio of assets and maintainingfinancial flexibility, while maximizing earnings and cash flows by controlling costs.

Algunos ejemplos Precuyo-Basamento en AND S. Lopez-V. Sissini-L Rodriguez-M. Lavia-G.Borges-S.Vargas

Setiembre 2010

Apache Energía Argentina

Page 2: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Columna Estratigráfica

Page 3: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Reservoir Facies

APA BLUE WHITE TEMPLATE.pptx 3

Los Molles

Chachil Limstn.

VV

V

V

V

V

V

V

V

+ + + + + + +

+ + + + + + +

+ + + + + +

+ + + +

+ + + +

+ + + + +

+ + + +

+ + +

+ + +

+ + + +

+ + + +

+ + +

+

4 0 M y

8 0 M y

IN TERSEN O N IAN

90 M y

IN TRAAPTIAN

112 M y

IN TRAVALAN G IN IAN

1 2 6 M y

IN TRAM ALM

144 M yIN TRAC ALO VIAN

1 5 4 M y

INTRALIAS

208 My

INTRATRIASSIC

215 My

Pue st o Touq uetSal i tra lC enten arioC utra l C o

C err o Ba nder aO c tógo noPor tezue lo Minas

C err o Ba nder a N ort eLom a la La taS ier ra B arr osaA l No rte de la D or sa lAgu ada To le doE l Tr ián guloE l Co rdó n

C err o Ba nder a N ort eLom a la La taBar ro sa No rte

C err o Ba nder a xp- 157

Volcanic rocks( Pyr oc lans tic &volcanic las tics )Epic las tics ( CG L)

”Serie

Sup ra

tria

s ic a

o A

nde

s itic

a ”

CR

ETA

CEO

US

JU

RA

SS

IC

TR

N eu q u en G r.

A g r io F m .

To rd i llo F m .

L o te na F m .

L ajas F m .

C ha llaco F m .

L o s M o lle s F m .

Lom a M on tosa F m .

R a yo so G r.

MENDO

ZA G

RO

UP

CUYO

GR

OUP

“F. PETR

OLÍF

ER

A“

50

0 m

C en ten ar io F m .

O roge n ic Te rtia ry

Q u intu co F m .

Vaca M ue rta F m .

L a p a F m .

P re c u y a n o G r.

L a P r im a ve ra F m .

C ha ch il L im e s ton es

G ra n ite

B a s e m e n t

B asa l C o ng lo m e ra te

o f the “S e rie S up ra tr ias ic a ”

SER. STA G .FO RM ATIO N S FIELD SA G E

QU

ATER

.

RE

SE

RV

.

SE

AL

D E EP G A S P R O J E C TSt ra t ig ra p h ic C o lu m n

Massive Volc

Volc. Bx

Volc. Bx

Page 4: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Gas Profundo en Basamento de la Cuenca Neuquina

Page 5: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Base MollesBase Molles

Mapa Estructural a la base de la Fm Molles

Page 6: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Distribución de las Facies

GR10.0 200

DTC100 40.0

28

00

29

00

30

00

ACO.x-1

GR10.0 200

PERFS8.00 -0.06

DTCO90 40.0

30

00

31

00

32

00

33

00

34

00

35

00

36

00

Apa.Nq.BZ-18

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

27

00

28

00

29

00

30

00

31

00

32

00

33

00

AEC.Nq.AC

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

24

00

25

00

26

00

AEC.Nq.AC.x

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

30

00

31

00

32

00

AC.xp-1010

2939 LMo

1212 BaVM

1895 SB_168

2982 BsCha

3156 LMo3156 BsPri3157 BsCha

3531 BsUPC

2802 LMo

1172 BaVM

3220 TBas

2833 BsPri

2516 LMo

1192 BaVM

2516 TBas2516 BsPri 3131 LMo

1134 BaVM

3132 BsPri

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

-100.000

0.000

100.000

200.000

300.000

400.000

500.000

Seismic Micro-Technology, Inc.

Project: ACCESS_AC_PO_CC_LN

Project Location:

Arbitrary Line G, Depth, Flattened Formation Top: Base Los Molles

leonardo.legarreta@BA-WS-LEGARRETA

05/22/08 10:27:51

0 5000 10000 12057Offset:

ACO.x-1 1 BZ-18 18 AC-2003 2003 AC.x-2001 2001 AC.xp-1010 1010

1994 m 5486 m 1964 m 2611 m

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

ACO-1 AC-2001BZ-18 AC-2003 AC-1010

Lower

Pre-Cuyo

(A)

Upper Pre-Cuyo

Los Molles Fm

Lower

Pre-Cuyo

(B)

Chachil Fm

Basement

GR10.0 200

DTC100 40.0

28

00

29

00

30

00

ACO.x-1

GR10.0 200

PERFS8.00 -0.06

DTCO90 40.0

30

00

31

00

32

00

33

00

34

00

35

00

36

00

Apa.Nq.BZ-18

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

27

00

28

00

29

00

30

00

31

00

32

00

33

00

AEC.Nq.AC

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

24

00

25

00

26

00

AEC.Nq.AC.x

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

30

00

31

00

32

00

AC.xp-1010

2939 LMo

1212 BaVM

1895 SB_168

2982 BsCha

3156 LMo3156 BsPri3157 BsCha

3531 BsUPC

2802 LMo

1172 BaVM

3220 TBas

2833 BsPri

2516 LMo

1192 BaVM

2516 TBas2516 BsPri 3131 LMo

1134 BaVM

3132 BsPri

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

-100.000

0.000

100.000

200.000

300.000

400.000

500.000

Seismic Micro-Technology, Inc.

Project: ACCESS_AC_PO_CC_LN

Project Location:

Arbitrary Line G, Depth, Flattened Formation Top: Base Los Molles

leonardo.legarreta@BA-WS-LEGARRETA

05/22/08 10:27:51

0 5000 10000 12057Offset:

ACO.x-1 1 BZ-18 18 AC-2003 2003 AC.x-2001 2001 AC.xp-1010 1010

1994 m 5486 m 1964 m 2611 m

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

GR10.0 200

DTC100 40.0

28

00

29

00

30

00

ACO.x-1

GR10.0 200

PERFS8.00 -0.06

DTCO90 40.0

30

00

31

00

32

00

33

00

34

00

35

00

36

00

Apa.Nq.BZ-18

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

27

00

28

00

29

00

30

00

31

00

32

00

33

00

AEC.Nq.AC

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

24

00

25

00

26

00

AEC.Nq.AC.x

GR10.0 200

PERFS8.00 -0.06

DT90 40.0

30

00

31

00

32

00

AC.xp-1010

2939 LMo

1212 BaVM

1895 SB_168

2982 BsCha

3156 LMo3156 BsPri3157 BsCha

3531 BsUPC

2802 LMo

1172 BaVM

3220 TBas

2833 BsPri

2516 LMo

1192 BaVM

2516 TBas2516 BsPri 3131 LMo

1134 BaVM

3132 BsPri

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

-100.000

0.000

100.000

200.000

300.000

400.000

500.000

Seismic Micro-Technology, Inc.

Project: ACCESS_AC_PO_CC_LN

Project Location:

Arbitrary Line G, Depth, Flattened Formation Top: Base Los Molles

leonardo.legarreta@BA-WS-LEGARRETA

05/22/08 10:27:51

0 5000 10000 12057Offset:

ACO.x-1 1 BZ-18 18 AC-2003 2003 AC.x-2001 2001 AC.xp-1010 1010

1994 m 5486 m 1964 m 2611 m

-100.00

0.00

100.00

200.00

300.00

400.00

500.00

ACO-1 AC-2001BZ-18 AC-2003 AC-1010

Lower

Pre-Cuyo

(A)

Upper Pre-Cuyo

Los Molles Fm

Lower

Pre-Cuyo

(B)

Chachil Fm

Basement

Primavera

Upper

Pre-Cuyo

Lower

Pre-Cuyo A

BasementMolles

ACO-1W E

Basement

AC-85 AC-2001BZ-22 BZ-18 AC-2003 AC-1010

Lower

Pre-Cuyo B

ChachilPrimavera

Upper

Pre-Cuyo

Lower

Pre-Cuyo A

BasementMolles

ACO-1W E

Basement

AC-85 AC-2001BZ-22 BZ-18 AC-2003 AC-1010

Lower

Pre-Cuyo B

Chachil

Page 7: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

7

-100 10SP

0 400GR

4 14CALI

4 14BS

1 10000RES90

1 10000RES60

1 10000RES10

1 100

100 10000

10000 1000GAS

3 5 0 0GR 0 20

FRDENO0 20

FRDENT0 .3 0

PHIS

140 40DT

1.95 2.95RHOB

0.45 -0.15NPHI

MetersMD TVDSS

2500

2600

-1700

MetersTVD

2500

2600

Core

Top Basement 2516 m MD -1662 m TVDSS

Well Test

1 Remark: After Acid: Flow x12mm Dry Gas Qg: 262000 m3/d, WHFP: 1680psi

AC

-20

01

(A

nti

clin

al C

amp

ame

nto

Mai

n)

CO

MP

OSI

TE

LOG

Top Basement2516 m MD(-1662) m TVDSS

2515/69 – After AcidFlow x12mm Dry Gas, Qg: 262,000m3/d,WHFP: 1680 psi98%

1%

1%

0%

PLT @10/04

Basamento Granítico

Page 8: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

8

AC

O. x

-1(A

nti

clin

al C

amp

ame

nto

Oe

ste)

CO

MP

OSI

TE L

OG

Base Molles2979 m MD(-2158 ) m TVDSS

Production Status:

@’07/05:

Qg: 4.2 MMCFD,

WHP: 1200 Psi x 25mm,

15% CO2, HS: 14ppm

-80 20SP

0 400GR

4 14CAL

4 14BS

1 1000M2RX

1 1000M2R1

0.1 10MPERM

1 100

100 10000

10000 1000GAS

3 5 0 0GR 0 10

FRDENO0 10

FRDENT0.3 0

PHIS30 0

MPHE30 0

MPHS

140 40DTC

1.95 2.95ZDEN

0.45 -0.15NPHI

0 10PE

0 5U

0 20TH

0 50K

MetersMD TVDSS

2900

3000

-2200

-2100

MetersTVD

2900

3000

Core

Base Cuyo 2979 m MD -2158 m TVDSS

Well Test

OH DST (2939/49m)

Qg: 10.6 MMcf/d (1hr flow)

WHP: 1450 psi (x14mm)

Interpretation:

WHFP: 5261 psi

K: 6.4 mD

Skin: 10

Barrier @50m

4 1/2" CSG k-55 PERFORATED 11.6

LB/FT , 140.73 m from 2,930.27 to

3.071 m

Chachil !!!

Page 9: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

MP

Eq

SP

IP

MP = Moldic Porosity

IP = Intraparticular

Porosity

SP =Spicules

Eq = Echinoderms

Silicified Limestone

1 22

Porosity

>0.01 0.01 0.1 <1

Permeability>0.01 0.01 0.1 <1 <10

Permeability

Page 10: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

10

AC

O. x

-2 (

An

ticl

inal

Cam

pam

en

to O

est

e)

CO

MP

OSI

TE L

OG

Top PreCuyo 3116 m MD(-2306) m TVDSS

Base Molles 3110 m MD(-2300) m TVDSS

3110/20 – 3140/45Before FracFlow Gas (x14mm), EGR: 70000m3/d, WHFP: 400psiAfter FracFlow Gas (x16mm), ERG: 323,560m3/d, WHFP: 1700psi

Pre-Cuyo

Page 11: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

11

Ignimbritas

v

C

P

P

A

Page 12: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

12

AC

S x-

1(A

nti

clin

al C

amp

ame

nto

Mai

n)

CO

MP

OSI

TE

LOG

Top PreCuyo2765 m MD(-1817) m TVDSS

Open Zone: 2736/3444Flow Gas x12mm, Qg: 203,249m3/d, WHFP: 1500psi

Top Basement2890 m MD(-1965) m TVDSS

98%

PLT @10/05

2%

-80 2 0SP

0 4 0 0GR

4 1 4CALI

4 1 4BS

1 1 0 0 0AHT90

1 1 0 0 0AHT10

1 100

100 10000

10000 1000GAS

350 0G R 30 -3 0

ANI0 10

FRDENO0 10

FRDENT0.3 0

PHIS

1 4 0 4 0DTCO

1 .9 5 2 .9 5RHOZ

0 .4 5 -0.15NPHI

0 1 0PEFZ

0 20URAN

0 20THOR

0 20POTA

MetersMD TVDSS

2800

2900

3000

3100

3200

3300

3400

-2500

-2400

-2300

-2200

-2100

-2000

-1900

-1800

MetersTVD

2800

2900

3000

3100

3200

3300

3400

Core

Top Precuyano 2765 m MD -1827 m TVDSS

Top Basement 2890 m MD -1952 m TVDSS

Well Test

Pre-Cuyo

Page 13: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Corona en Andesita

Page 14: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Breccias con matrix resistiva

Pre-Cyo Resistive Volcanic Bx

BZ-18AC-86 ACS-3

Page 15: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Breccias con matriz conductiva

ACO-3 ACO-3 ACS-3

Page 16: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Bimagen en basamento GraníticoGranite Basement and Indeced Frac Granite Basement With Open Frac Granite Basement With Open Frac

Page 17: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

17

-90 10SPC

0 400GR

4 14CALI

4 14BS

1 10000ILD

1 10000ILM

1 10000SFLU

1 100

100 10000

10000 1000GAS

3 5 0 0GR 30 -30

ANI0 20

FRDENO0 20

FRDENT0 .3 0

PHIS

140 40DTCO

1.95 2.95RHOZ

0.45 -0.15NPHI

0 10PEFZ

MetersMD TVDSS

2200

2300

2400

2500

2600

2700

2800

2900

3000

3100

3200

3300

3400-2600

-2500

-2400

-2300

-2200

-2100

-2000

-1900

-1800

-1700

-1600

-1500

-1400

MetersTVD

2200

2300

2400

2500

2600

2700

2800

2900

3000

3100

3200

3300

3400

Core

Top Basement 2229 m MD -1392 m TVDSSWell Test

2628/716 – After FracFlow x10mm wet gas, Qg: 3,351m3/d, WHFP: 20 psi

3454/78 – After Frac, Swab Water, 0.75m3/h, L: 3325m

3421/42 – After Frac, Swab Water, 0.21m3/h, L: 3320m

3340/53 – After Frac, Swab Water, 0.33m3/h, L: 3205m

3095/115 – After Frac, Flow wet Gas,Qg: 512 m3/d, WHFP: 3 psi

2550/75 – After Frac, Swab Water,L: 2428m

AC

E x-

1(A

nti

clin

al C

amp

ame

nto

Est

e)

CO

MP

OSI

TE L

OG

2248/322 – After AcidFrac Flow x12mm wet gas, Qg: 82,968m3/d, Cond (20%), WHFP: 980psi

Top Basement2229 m MD(-1392) m TVDSS

2422/43 – After AcidFrac Flow water + Gasoline 15% x 10mm, 0.27 m3/h WHFP: 340psi

5% Liq

PLT @ /03

11%

36%

48%

Basamento Granìtico

Page 18: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

18

-90 10SPC

0 400GR

4 14CALI

4 14BS

1 10000AHT90

1 10000AHT60

1 10000AHT10

1 100

100 10000

10000 1000GAS

3 5 0 0GR 0 20

FRDENO0 20

FRDENT0 .3 0

PHIS

140 40DT

1.95 2.95RHOZ

0.45 -0.15NPHI

0 10PEFZ

MetersMD TVDSS

2700

2800

2900

3000

3100

-2300

-2200

-2100

-2000

-1900

MetersTVD

2700

2800

2900

3000

3100

Core

Conglomerate Top 2695 m MD -1872 m TVDSS

Top Basement 2775 m MD -1952 m TVDSS

Arenisca_Fina_Top 2842 m MD -2019 m TVDSS

Cristaline_Basement_Top_II 2897 m MD -2074 m TVDSS

Well Test

2824/3103 – After FracFlow x10mm 0.35 m3/h, Cond (25%),Og: 92.800 m3/d, WHFP: 880 psi

2700/81 - WHFP: 3110 psiFlow x 14mm, Og: 89,168 m3/d

PO

x-1

(P

ort

ezu

elo

s O

est

e)

CO

MP

OSI

TE L

OG

Top Basement2775 m MD(-1952) m TVDSS

Top CGL 2695 m MD(-1872) m TVDSS

Top CGL II2842 m MD (-2010) m TVDSS

Top Basement2897 m MD(-2074) m TVDSS

PLT @ /04

Basamento + Primavera (Primavera?)

Page 19: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Base C

uyo

1 13

Porosity

Primavera

Page 20: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

AC-Primavera

ACS-3

ACS-3

ACO-3AC-85

Page 21: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

F

B

PGCa

FK

Q

PG

PO.a-2

>1 7

>0.01

Porosity Permeability

Corona en Basamento Granìtico

Page 22: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

22

2018/57 –Flow Gas, Qg: 31,484 m3/d, WHFP: 245 psi

2489/2688 – Dry

2309/455 –Swab Water 0.12 m3/h, L: 2257m + gas

2088/2139 – After FracSwab Water 0.24 m3/h, L: 2016m

PN

-1 (

Po

rtez

ue

los

No

rte

) C

OM

PO

SITE

LO

G

Base Molles2295 m MD (-1361) m TVDSS

-90 10SPC

0 300GR

4 24CALI

4 24BS

1 1000ILD

1 1000AHT60

1 1000SFLU

1 100

100 10000

10000 1000GAS

3 5 0 0GR140 40

DTCO1.95 2.95

RHOZ0.45 -0.15

NPHI0 10

PEFZ

MetersMD TVDSS

1850

1900

1950

2000

2050

2100

2150

2200

2250

2300

2350

2400

2450

2500

2550

2600

2650-1700

-1650

-1600

-1550

-1500

-1450

-1400

-1350

-1300

-1250

-1200

-1150

-1100

-1050

-1000

-950

Core

Top Precuyano 2295 m MD -1361 m TVDSS

Precuyo

Page 23: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Mapa Estructural en Tiempo Bloques Anticlinal Campamento-Portezuelo-Collòn Cura

1 Km

Block border 3D data borderPreCuyo absent

& Basement structural trends

Mapa estructural-altos de basamento

Page 24: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

Guanaco

NQN Gp

RAY

CEN

MUL

QUI + VM

LOT + LAJ

MOL

PCUY + BAS

A (WNW) A’ (ESE)

Page 25: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

25

-100 10SP

0 400GR

4 14CALI

4 14BS

1 10000AHT90

1 10000AHT60

1 10000AHT10

1 1 0 0

1 0 0 1 0 0 0 0

1 0 0 0 0 1000GAS

3 5 0 0GR 30 -30

ANI0 20

FRDENO0 20

FRDENT0 .3 0

PHIS

140 40DTCO

1.95 2.95RHOZ

0.45 -0.15NPHI

0 10PEFZ

MetersMD TVDSS

2200

2300

2400

2500

2600

2700-2100

-2000

-1900

-1800

-1700

-1600

MetersTVD

2200

2300

2400

2500

2600

2700

Core

Top Precuyano 2237 m MD -1631 m TVDSS

Top Basement 2306 m MD -1699 m TVDSS

Well Test

Gu

-10

92

(G

uan

aco

De

ep

) C

OM

PO

SITE

LO

GTop PreCuyo 2237 m MD (-1631) m TVDSS

Top Basement 2306 m MD (-1699) m TVDSS

Open Hole Flow x10mm wet Gas,Qg: 133,575 m3/dWHFP: 1580 psi

PLT @ 05/04

88%

12%

Pozo Tipo en Guanaco

Page 26: Apache Energía Argentina Gas Profundo · Agrio Fm. Tordillo Fm. Lotena Fm. ... 350 GR 0 30 -30 ANI 0 FRDENO 20 0 FRDENT 20 0 .3 PHIS 0 ... 1950 2000 2050 2100 2150 2200 2250 2300

26

-100 10SP

1 1000ILD

1 1000SFL

2 0 -100S P

MetersMD TVDSS

2600

2700

2800

2900

3000

3100

3200

3300

3400

3500-2900

-2800

-2700

-2600

-2500

-2400

-2300

-2200

-2100

-2000

Core

Top Precuyano 2690 m MD -2080 m TVDSS

SP x

-2 (

Sen

de

ro P

ed

rego

so)

CO

MP

OSI

TE L

OG

Top PreCuyo 2690 m MD (-2080) m TVDSS

Pre-Cuyo- Pozo abndonado antiguo