Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies...

39
Antibody Screening Lab 6 Practical Blood Bank

Transcript of Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies...

Page 1: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Antibody ScreeningLab 6

Practical Blood Bank

Page 2: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Antibody Detection The test used to detect antibodies is called

an antibody screen Antibody screens are used for:

Patients needing a transfusion Pregnant women Cases of transfusion reactions Blood and plasma donors

Uses patients plasma/serum against reagent red cells to detect unexpected antibodies

Unexpected antibodies are found in addition to the expected anti-A and/or anti-B

Page 3: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Antibody Screen

Unexpected antibodies are a result of red cell stimulation (transfusion, HDN)

Unexpected antibodies may be: Clinically significant (IgG) Not clinically significant (IgM)

Page 4: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Clinically significant antibodies Usually IgG React best at 37° and AHG phase (IAT) Clinically significant antibodies are associated

with hemolytic transfusion reactions (HTR) and hemolytic disease of the newborn (HDN)

Page 5: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Performing an antibody screen

Patients plasma/serum is incubated with screening cells

After incubation, an IAT is performed (indirect antiglobulin test) using AHG reagent

This will detect any IgG antibodies.

Page 6: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Screening Cells Screening cells are single or pooled donor

group O cells, however, single-donor vials offer increased sensitivity

Why group O? so anti-A and anti-B won’t react Screening cells come in sets of 2 or 3 vials each Each vial (donor) has been phenotyped for each

antigen 18 antigens are required on at least one of the

vials: D, C, E, c, e, M, N, S, s, P1, Lea, Leb, K, k, Jka, Jkb, Fya, Fyb

Page 7: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Screening cells Screening cells come with a sheet of paper called

an antigram Screening cells are an already prepared 2-5% RBC

suspension An antigram (2 or 3 cells) will list the antigens

present in each vial A reaction to one or more cells indicates the

presence of an unexpected antibody

Page 8: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

2 Cells Antigram

Page 9: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

The technologist should be aware that some antigens demonstrate dosage

An attempt should be made to used screening cells that are homozygous for the clinically significant antigens (Rh, Duffy, Kidd). Just be aware that different strengths can occur Homozygous antigens will react stronger Heterozygous antigens will react weaker

Page 10: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Examples

Fya Fyb

SCI + + 2+

SCII 0 + 4+

Fya Fyb

SCI + 0 4+

SCII 0 + 0

If patient’s serum contains anti-Fya, there will be a stronger reaction because SCI is homozygous for the Duffy antigen

In this case, the person has anti-Fyb. The antibody reacts weaker with SCI (heterozygous) and stronger with SCII (homozygous)

Page 11: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Screening Cells Screening cells may also contain low

incidence antigens like V, Cw, and Kpa

The presence of these antigens is not required for screening cells

Page 12: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Pretransfusion Screening Screening for antibodies is normally performed

prior to blood transfusion to detect antibodies that react at body temperature (37°)

Colder reacting antibodies (RT and below) are therefore considered insignificant and just cause interference when performing lab testing

The only important thing to remember concerning cold antibodies is that they may bind complement if a persons body temperature becomes low Open-heart surgery Hypothermia

Page 13: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Autocontrol Tests patient serum with their own red cells Some labs may or may not perform an

autocontrol (AC) with the screen…depends on the hospital

However, the AC should be run with the antibody panel…we’ll discuss this later

AC is incubated with the antibody screen (or antibody panel)

If a lab uses an AC with the screen and it is positive, they may run a DAT (patient cells + AHG) to detect in vivo coating

Page 14: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Autocontrol The AC and DAT can help in determining

whether the antibodies are directed against the patient’s cells or transfused cells (allo or autoantibody).

ScreenAntibody

Panel (w/AC)If Positive

If P

osi

tive

DAT

Page 15: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Potentiators Used in antibody detection and

identification to enhance antigen-antibody reaction Saline (may only enhance if incubated long

time) Low-ionic strength solution (LISS)…

common Bovine serum albumin (BSA) Polyethylene glycol (PEG) Proteolytic enzymes (can destroy some

antigens)

Page 16: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Potentiators

Albumin Serum/cell mixture should incubate at least 20 - 30 minutes; doesn’t enhance warm autoantibodies

LISS Incubation time of 10 minutes;lowers ionic strength allowing better reaction; sensitive and quick!

PEGPolyethylene

glycol

Enhances warm autoantibodies; does not react well with insignificant antibodies (IgM)

Page 17: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Testing Techniques – Saline Tube Simplest to perform. Mix serum or plasma with saline suspended RBCs,

centrifuge and read, incubate at RT or 37C. Used in crossmatching to detect ABO

incompatibility. In antibody tests used to detect IgM antibodies

which react preferentially at RT: anti-M, -N, -P1, -Le and –I

Page 18: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Testing Techniques – Bovine Albumin Tube Utilized to enhance agglutination of IgG

antibodies since 1945. Decreases amount of time required for

incubation. Controversy: Decrease zeta potential (affects

second stage of agglutination) or due to function of ionic strength of albumin diluents does it increase uptake of antibody onto cells?

Many antibodies have enhanced reactivity when albumin is added to test system.

Page 19: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Testing Techniques – LISS Tube Low Ionic Strength Saline shortens incubation

time. Increases antibody uptake onto cell, enhancing

agglutination. Several important factors to consider:

Incubation time and sensitivity subsequent to AHG depends upon desired ionic conditions.

Adding additional serum will increase ionic strength, must not be done.

MUST adhere to manufacturer’s instructions.

Page 20: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Testing Techniques – PEG Tube Polyethylene Glycol (PEG) is a water soluble, neutral

polymer which is an effective potentiator of antigen-antibody reactions.

Advantages over albumin include: Increases rate of detection of clinically significant

antibodies. Decreases detection of clinically insignificant

antibodies. May decrease need for other enhancement

techniques. Procedure

Serum or plasma added to RBCs, perform IS. Add PEG and incubate at 37C – IS NOT READ AFTER

37C Wash and add AHG.

Page 21: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Testing Techniques – Enzymes Tube More appropriate for antibody ID than routine

testing. GREATLY enhance reactivity of Rh antibodies. CANNOT be only method used as M, N, S, Fy and

other antigens are destroyed, those antibody specificities would not be detected.

Enzymes used include Papain Bromelain Trypsin Ficin – MOST POPULAR

Page 22: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Procedure Antibody screening tests using a test tube method are

performed in a variety of ways. American Association of Blood Banks Standards requires that these tests detect clinically significant antibodies and that they include a 37°C incubation and an AHG test. Generally, testing includes the following steps: 1. Appropriately label each tube. 2. Add 2 drops of patient serum to each tube. 3. Add 1 drop of appropriate screening cells to each tube. 4. Centrifuge, then gently resuspend the cell button and

read for agglutination or hemolysis. Record results. It should be noted that this step is optional because most significant antibodies are IgG and do not cause agglutination of saline-suspended RBCs.

Page 23: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

5. Add 2 drops of enhancement reagent to each tube (may vary with enhancement reagent used).

6. Incubate at 37°C for 15 to 30 minutes, according to the manufacturer's recommendation for the enhancement reagent being used. During the incubation, antibody in the patient serum will bind to antigens on the reagent RBC. This is called the sensitization phase.

7. Centrifuge, then gently resuspend the cell button and read for agglutination or hemolysis. Record results.

8. Fill all tubes with saline, centrifuge, and discard supernatant. This is called washing, and it removes unbound IgG that neutralizes the AHG reagent.

9. Repeat step 8 two or three times to remove unbound antibody completely.

10. Add 2 drops of AHG to each tube (polyspecific or anti-IgG).

Page 24: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

11. Centrifuge, then gently resuspend the cell button and read for agglutination or hemolysis. Tests that are macroscopically negative are usually checked for microscopic agglutination. Record results.

12. Add 1 drop of Coombs control cells (or "check cells") to all negative tests.

13. Centrifuge and read for agglutination. Repeat test if agglutination is not observed.

Page 25: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Grading Reactions

Page 26: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Interpretation Agglutination or hemolysis at any stage of testing is a

positive test result, indicating the need for antibody identification studies. However, evaluation of the antibody screen and autologous control results can provide clues and give direction for the identification and resolution of the antibody or antibodies.

The investigator should consider the following questions: 1. In what phase(s) did the reaction(s) occur? 2. Is the autologous control negative or positive? 3. Did more than one screening cell sample react, and, if so,

did they react at the same strength and phase? 4. Is hemolysis or mixed-field agglutination present? 5. Are the cells truly agglutinated, or is rouleaux present?

Page 27: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Interpretation

1. In what phase(s) did the reaction(s) occur?

Antibodies of the IgM class react best at low temperatures and are capable of causing agglutination of saline-suspended RBCs (immediate spin reading). Antibodies of the IgG class react best at the AHG phase. Of the commonly encountered antibodies,

anti-N. anti-I, and anti-PI are frequently IgM,

whereas those directed against Rh. Kell. Kidd, and Duffy antigens are usually IgG.

Lewis and M antibodies may be IgG, IgM, or a mixture of both.

Page 28: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

2. Is the autologous control negative or positive?

A positive antibody screen and a negative autologous control indicate that an alloantibody has been detected.

A positive autologous control may indicate the presence of autoantibodies or antibodies to medications.

If the patient has been recently transfused, the positive autologous control may be caused by alloanti body coating circulating donor RBCs.

Evaluation of samples with positive autologous control or DAT results is often complex and may require a lot of time and experience on the part of the investigator.

Page 29: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

3.Did more than one screening cell sample react, and, if so, did they react at the same strength and phase? More than one screening cell sample is positive 4. when the patient has multiple antibodies, 5. when the antibodies' corresponding antigen is found

on more than one screening cell6. when the patient's serum contains an autoantibody.

A single antibody specificity should be suspected when all cells react at the same phase and strength. Multiple antibodies are most likely when cells react at different phases and strengthsAnd autoantibodies are suspected when the autologous control is positive. .

Page 30: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

4. Is hemolysis or mixed-field agglutination present? Certain antibodies-such as anti-Lea, anti-Leb, anti P+P1+Pk, and anti-Vel-are known to cause in vitro hemolysis.

Mixed-field agglutination is associated with anti-Sda and Lutheran antibodies.

Page 31: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

5. Are the cells truly agglutinated, or is rouleaux present?

Serum from patients with altered albumin-to-globulin ratios (e.g., patients with multiple myeloma) or who have received high-molecular-weight plasma expanders (e.g.. dextran) may cause nonspecific aggregation of RBCs, known as rouleaux.

Rouleaux is not a significant finding in antibody screening tests, but it is easily confused with antibody-mediated agglutination.

Knowledge of the following characteristics of rouleaux helps in differentiation between rouleaux and agglutination:

a. Cells have a "stacked coin" appearance when viewed microscopically.

b. Rouleaux is observed in all tests containing the patient's serum, including the autologous control and the reverse ABO typing.

Page 32: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

c. Rouleaux does not interfere with the AHG phase of testing because the patient's serum is washed away prior to the addition of the AHG reagent.

d. Unlike agglutination, rouleaux is dispersed by the addition of 1 to 3 drops of saline to the test tube.

Page 33: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Limitations Very effective in detecting antibodies If negative, then the crossmatch should be

compatible Antibody screening tests are designed to detect

significant RBC antibodies, but they cannot detect all such antibodies. Antigens with frequencies of less than 10 percent (e.g., Cw. Lu-, Kpa) are not usually represented on screening cells, and, as a result, their corresponding antibodies are not detected in routine screening tests.

Antibody screening tests may also yield negative results when the titer or concentration of antibody drops below detectable limits.

Page 34: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Limitations

antibody levels decrease over time when the individual is no longer exposed to the corresponding antigen. If the level of an RBC antibody drops too low, results of antibody screening tests and crossmatches will appear negative and may lead to transfusion of donor units that carry the corresponding antigen.

Re exposure to the RBC antigen will elicit a secondary immune response, resulting in a dramatic increase in the antibody titer and possible immunologic destruction of the transfused RBCs. this is called a delayed hemolytic transfusion reaction (DHTR) because it occurs days or weeks after the transfusion.

The student should keep in mind that proper performance and interpretation of antibody detection tests minimize the risk of DHTRs.

Page 35: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Patient History GET THE HISTORY!!

Mixed red cell populations from a previous transfusion can remain for up to 3 months

Patient may have come from another hospital Some diseases are associated with antibodies Some antibodies occur at a higher frequency in some

races Get diagnosis, age, race, etc…

Page 36: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Example 1Screening

CellIS 37°C AHG CC*

I 0 0 0

II 0 0 2+ ND

• IgG antibody

• Single specificity

• CC: Coombs Control Red Blood Cells• ND: Not Done

Page 37: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Example 2

Screening Cell IS 37°C AHG CC

I 0 0 3+

II 0 2+ 3+

• IgG antibody

• Multiple specificities

Page 38: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Example 3Screening Cell IS 37°C AHG CC

I 1+ 0 0 II 3+ 0 0

• IgM antibody

• Single specificity showing dosage

Neg AHG, add CC

Page 39: Antibody Screening Lab 6 Practical Blood Bank. Antibody Detection The test used to detect antibodies is called an antibody screen Antibody screens are.

Example 4

Screening Cell IS 37°C AHG CC

I 0 0 2+

II 0 0 2+

• IgG antibody

• Allo or autoantibody?

(don’t know without further testing)