ANTARES - C · The ventilation unit with an incorporated active cooling circuit, ANTARES - C, in...

26
ANTARES - C

Transcript of ANTARES - C · The ventilation unit with an incorporated active cooling circuit, ANTARES - C, in...

  • ANTARES - C

  • FIELD OF APPLICATION

    ANTARES - C

    ANTARES C

    0 100 120 140 180 200 220 240 280 300 320 340 380

    Roof Top for indoor plug-in air conditioning

    3

    AN

    TAR

    ES C

  • ANTARES C

    4

    EXTRACT AIR

    FRESH AIR

    SUPPLY AIR

    EXHAUST AIR

    Compressor

    Evaporator

    Condenser

    →→

    The ventilation unit with an incorporated active cooling circuit, ANTARES - C, in addition to promoting healthy ventilation inside the rooms, supplies air at a temperature up to 8°C lower than the outside temperature.

    The unit consists of:

    • Ventilation unit with high-performance supply and return plug fan fans for nominal volumetric flow rates of 120 m3/h and head of 50 Pa, with the possibility of reaching up to 280 m3/h, with reduced energy consumption thanks to the electronically controlled motors.

    • Module with active cooling circuit equipped with horizontal compressor to limit the height of the space

    The machine does not need to drain condensate as it is vaporized in the expelled air.Recommended unit for the booths with a total volume of 15 m3 The air flow can go from a minimum of 120 m3/h to a maximum of 240 m3/h with a set point that can be set from 21°C to 25°C.

    The air distribution must be as uniform as possible inside the box with a careful choice of diffusers and the use of insulated channels to avoid condensation.It is recommended to limit number of bends in the air distribution duct work in order to maintain cooling performance levels and contain the pressure drop and consequently the noise levels.For the installation, it is recommended to use some type of damper/vibration absorbers (installer care) to avoid direct contact between the unit sheet metal and the room structure which may result in transmission of noise and/or vibrations.

  • AN

    TAR

    ES C

    DIMENSIONAL

    DimensionLunghezza (A) [mm] 940

    Larghezza (B) [mm] 940

    Altezza (C) [mm] 170

    Peso [kg] 63

    5

  • TECHNICAL DATA SHEET

    6

    Technical and dimensional data ANTARES - C

    Supply connection 2xDN125

    Extract connection 2xDN125

    Fans

    Nominal Air flow m3/h 120

    Power input [W] 200

    Current consumption [A] 1,9

    Supply voltage [V/Ph/Hz] 230/1/50

    Compressor

    Supply voltage [V/Ph/Hz] 230/1/50

    Cooling powercon T

    est=22°C, U

    r= 50%, T

    mand= 14°C, U

    r= 66%

    [W] 690

    Power input, at nominal operating point [W] 253

    Absorption at nominal operating point [A] 1,12

    Power input, max [W] 310

    Current consumption, max [A] 2,0

    Refrigerant fluid [-] R134a

    Condensation water dissipater

    Power input [W] 1270

    Current absorption [A] 5

    General data

    Total power input, max [W] 1780

    Total absorption at nominal operating point [A] 8,9

    Average current absorption [A] 4

    Noise data

    Sound pressure level in free field,1m distance flow rate 120 m3/h, ducted unit

    [dB(A)] 45

  • SUPPLY AIR FLOW

    EXHAUST SUPPLY AIR

    EXTERNAL AIR FLOW

    EXHAUST AIR FLOW

    SUPPLY AIR FLOW

    EXHAUST AIR FLOW

    FIL

    TE

    RF

    ILT

    ER

    EXAMPLE OF THE MACHINE INSTALLED

    MACHINE LAYOUT

    AN

    TAR

    ES C

    7

  • NOTE: AS AN ALTERNATIVE TO THE SIMPLIFIED DISPLAY

    DESCRIPTION

    Evolution display + Bluetooth

    Evolution display and transmitter Temperature + Humidity,without Bluetooth

    Evoltion display and transmitter Temperature + Humidity + Bluetooth

    EPJ COLOR touch screen

    NOTE: THE STANDARD UNIT IS ALREADY EQUIPPED WITH:

    DESCRIPTION

    Controller

    Cable

    Easy display

    ACCESSORIES

    AN

    TAR

    ES C

    9

  • ACCESSORIES

    60600244

    It is a sanitization and decontamination module with cold plasma technology, for the purification and decontamination of the aeraulic ducts, specially designed to be easily installed wherever you want to prevent or eliminate the formation of bacterial colonies on the duct surfaces.The sanitization technology developed for the medical sector is a simple and essential module that is made available for residential environments and is designed for the integrated management of VMC systems. The control and functions can be controlled remotely by the system heat recovery unit.

    The main features of the AERONIX module are:• High efficiency: reduction of microbial load and volatile organic compounds up to 99%;• Low energy consumption: from 20VA;• Strong deodorant action: eliminates odors from the air in transit;• Natural process: does not use or produce residual chemicals

    It can be used in any type of VMC system (Controlled Mechanical Ventilation) thanks to the simple installation in the distribution boxes for an air flow rate of up to 500 m3/h. The operation can be continuous or in cycles, depending on the connection.

    10

    COMPONENT DESCRIPTION

    Wall mounting tab Electrical socket with fuse holder

    Electrical part container Input connector and serial signal

    Ionizing tube Out put connector for alarm signaling

    Condenser activation bracket Illuminated ON / OFF switch

    EBOX fixing holes

  • ACCESSORIES

    60140028

    The CO2 sensor detects gas concentrations due to human respiration in commercial and residential air-conditioned

    environments.Provides the control with a proportional signal to manage the recirculation of the external air fans when necessary, thus contributing to the energy efficiency of the climatio control of buildings, and ensuring good air quality for people who stay in the environment (e.g. shopping malls, shops, theaters, offices).

    AN

    TAR

    ES C

    11

    TECHNICAL DATA

    Voltage supply 24 V AC / DC (± 10%)

    Absorbed power

  • ACCESSORIES

    The ducts and fittings of the PLAST line can be used in all residential ventilation systems, both in single flow systems and in dual flow systems with heat recovery.They represent the ideal solution in environments with reduced installation spaces, both in individual homes and in collective systems.The fittings are simple to assemble to the ducts and are equipped with a gasket which guarantees a class D seal.The mechanical seal is guaranteed by the fixing clips placed on the ends of the fittings.

    Upon request, PLAST is available in a version with antibacterial treatment.

    ADVANTAGES

    • Ducts with a height of only 55 mm, suitable for installation in a false ceiling = reduced size

    • Low pressure drops compared to flexible conduits

    • Rigid ducts = greater impact resistance

    • Simple assembly with reduced installation times

    • All accessories are equipped with sealing gaskets = class D aeraulic seal

    TECHNICAL FEATURES

    • Fire reaction: self-extinguishing not classified

    • Maximum operating temperature: + 80 ° C

    • Thermal conductivity: 0.0544 - 0.0662 W / m ° C

    Equivalent circular diameter: - rectangular duct 55 x 100 mm: ø 80 x 100 mm - rectangular duct 55 x 220 mm: ø 125 r

    Recommended courses - For a rectangular duct 55 x 100 mm average: 50 m3/h (v = 2.5 m / s) max: 90 m3/h (v = 4.0 m / s) - For a rectangular duct 55 x 220 mm average: 100 m3/h (v = 2.5 m / s) max: 180 m3/h (v = 4.0 m / s)

    50400031 Vertical curve at 90 °

    50400030 Junction R/C

    50400027Junction

    50400035 Collar50400024

    Conducted

    12

  • 50

    40

    00

    28

    Rac

    cord

    o o

    rizz

    on

    tale

    m

    asch

    io r

    ect.

    /cir

    c.

    55

    x22

    0-1

    25

    50

    40

    00

    26

    Co

    nd

    ott

    o s

    ilen

    ziat

    o

    con

    att

    acco

    mas

    chio

    , 5

    5x2

    20

    x10

    00

    50

    40

    00

    32

    Cu

    rva

    ori

    zzo

    nta

    le a

    90

    °, 5

    5x2

    20

    50

    40

    00

    38

    Co

    nd

    ott

    o s

    ilen

    ziat

    o

    con

    att

    acco

    mas

    chio

    , 5

    5x2

    20

    x50

    05

    04

    00

    02

    4C

    on

    do

    tto

    ret

    tan

    gola

    re

    in P

    VC

    , 55

    x22

    0

    50

    40

    00

    23

    Val

    vola

    bo

    rea

    12

    5

    50

    40

    00

    51

    Tub

    o P

    VC

    12

    55

    04

    00

    02

    9R

    acco

    rdo

    ver

    tica

    le

    mas

    chio

    rec

    t./c

    irc.

    5

    5x2

    20

    -12

    5

    È p

    oss

    ibile

    sce

    glie

    re a

    ltri

    co

    dic

    ip

    er c

    on

    figu

    razi

    on

    i per

    son

    aliz

    zate

    CA

    NA

    LIZ

    ZA

    ZIO

    NE

    STA

    ND

    AR

    D

    Dev

    on

    o e

    sser

    e ta

    glia

    ti a

    m

    isu

    ra d

    a p

    arte

    del

    l’uti

    lizza

    tore

    NO

    TE

    13

  • 50400024

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400024 - 110 55 110 3000 1,5 3,1 6,1

    50400024 - 220 55 220 3000 0,7 1,3 2,7

    RECTANGULAR DUCT IN PVC

    50400027HORIZONTAL MALE CONNECTION RECT./RECT.

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400027 - 110 55 110 109 0,2 0,5 1,0

    50400027 - 220 55 220 120 0,1 0,2 0,5

    14

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

  • 50400028HORIZONTAL MALE CONNECTION RECT./CIRC.

    TYPEA B C D Pressure drop (Pa)

    mm mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400028 - 110 100 110 55 210 2,3 4,5 9,1

    50400028 - 220 125 220 55 328 0,3 0,7 1,4

    50400029MALE ELBOW BEND WITH ROTATING OFFSET SPIGOT RECT./CIRC.

    TYPEA B C D Pressure drop (Pa)

    mm mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400029 - 110 100 110 55 165 7,4 14,7 29,5

    50400029 - 220 125 220 55 195 3,6 7,3 14,5 AN

    TAR

    ES C

    15

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

  • 50400031VERTICAL BEND 90°

    TIPOA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400031 - 110 55 110 120 6,1 12,2 24,3

    50400031 - 220 55 220 165 2,5 5,0 9,9

    50400032HORIZONTAL BEND 90°

    TIPOA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400032 - 110 55 110 170 8,6 17,2 34,4

    50400032 - 220 55 220 310 4,2 8,4 16,8

    16

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

  • 50400033FLEXIBLE BEND

    TIPOA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400033 - 110 55 110 540 19,0 38,0 76,1

    50400033 - 220 55 220 540 6,2 12,4 24,8

    50400026SILENCED DUCT WITH MALE CONNECTION

    TIPOA B C

    mm mm mm

    50400026 - 220 55 220 1000

    Sound pressure level

    63 HZ 125 HZ 250 HZ 500 HZ 1 kHz 2 kHz 4 kHz 8 kHz

    -1 0 11 12 13 37 23 15

    AN

    TAR

    ES C

    17

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

  • 50400038SILENCED DUCT WITH MALE CONNECTION

    Sound pressure level

    63 HZ 125 HZ 250 HZ 500 HZ 1 kHz 2 kHz 4 kHz 8 kHz

    -1 -3 5 6 12 18 12 9

    TYPEA B C

    mm mm mm

    50400038 - 220 55 220 500

    50400051PVC PIPE

    TYPE ø LONG.(mm)

    50400051 - 100 100 1000

    50400051 - 125 125 1000

    18

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

  • 50400023DIFFUSOR PCA 125

    MODELø D1(mm)

    ø D2(mm)

    Hmin(mm)

    Hmax(mm)

    50400023 - 80 74 110 9 20

    50400023 - 125 119 165 12 24

    Diffusers in galvanized steel powder coated.The diffusers are suitable for both delivery and recovery, depending on the particular geometry of the diffusers themselves.The front of the diffusers can be removed to allow cleaning of the interior components or to access the channel.

    50400040FLEXIBLE SOUND ABSORPTION PIPE

    Diameterø

    Package m

    Dim. conf.mm

    127 10 205x205x1100

    AN

    TAR

    ES C

    19

    TO BE INSTALLED ONLY ON THE EXTRACT AIR

    TO BE INSTALLED ONLY ON THE EXTRACT AIR Sound absorbing duct consisting of a harmonic steel spiral wrapped in a 74µm micro-perforated

    aluminium/polyester laminate.Insulated fibreglass mattress density 18 kg/m3 and

    thickness 25 mm.

    External coverAluminum/polyester 49µm.

    - Reaction to fire: class 1-1- Certificate: CSI 0104/04/RF

    - Approval PD2229C0D-10003

    Characteristics

    Reaction to fire Class 1

    Duct aluminium/polyester

    Isolation 25mm lana di vetro 18kg/m3

    λ (W/mK) 0,039

    External sheath aluminium/polyester

    Temp. of use -30°C + 150°C

    Air speed max 30 m/s

    Max pressure 2000 Pa

    Box Box 10 m

  • 50400037RECTANGULAR CAP

    TYPEHeight Width

    mm mm

    50400037 - 110 55 110

    50400037 - 220 55 220

    50400036RECTANGULAR GRID

    Duct Grid

    TYPEHeight Width A B

    mm mm mm mm

    50400036 - 110 55 110 88 137

    50400036 - 220 55 220 80 245

    50400035FLAT CHANNEL CLIP

    50400034

    TYPEHeight Width

    mm mm

    50400034 - 110 55 110

    50400034 - 220 55 220

    WALL PLATE

    TYPEHeight Width

    mm mm

    50400035 - 110 55 110

    50400035 - 220 55 220

    20

  • 50400064ISOLATED HORIZONTAL MALE CONNECTION RECT./RECT.TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400064 110 55 110 109 0,2 0,5 1,0

    50400064 220 55 220 120 0,1 0,2 0,5

    21

    50400065ISOLATED HORIZONTAL MALE CONNECTION RECT./CIRC.

    TYPEA B C D Pressure drop (Pa)

    mm mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400065 110 100 110 55 210 2,3 4,5 9,1

    50400065 220 125 220 55 328 0,3 0,7 1,4

    TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

  • 22

    50400063ISOLATED SILENCED DUCT WITH MALE CONNECTIONTO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    Sound absorption level

    63 HZ 125 HZ 250 HZ 500 HZ 1 kHz 2 kHz 4 kHz 8 kHz

    -1 -3 5 6 12 18 12 9

    TYPEA B C

    mm mm mm

    50400063 220 55 220 1000

    50400066ISOLATED MALE ELBOW BEND WITH ROTATING OFFSET SPIGOT RECT./CIRC.

    TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    TYPEA B C D Pressure drop (Pa)

    mm mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400066 110 100 110 55 165 7,4 14,7 29,5

    50400066 220 125 220 55 195 3,6 7,3 14,5

  • 23

    50400062ISOLATED RECTANGULAR DUCT IN PVC

    TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    50400067ISOLATED VERTICAL BEND 90°TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400062 110 55 110 1500 1,5 3,1 6,1

    50400062 220 55 220 1500 0,7 1,3 2,7

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400067 110 55 110 120 6,1 12,2 24,3

    50400067 220 55 220 165 2,5 5,0 9,9

  • NOTE

    50400068ISOLATED HORIZONTAL BEND 90°

    TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    TYPEA B C Pressure drop (Pa)

    mm mm mm 54 m3/h 108 m3/h 216 m3/h

    50400068 110 55 110 170 8,6 17,2 34,4

    50400068 220 55 220 310 4,2 8,4 16,8

    50400069ISOLATED PVC PIPE

    TO BE COMPULSORILY INSTALLED ON THE SUPPLY AIR

    TYPE ø LONG.(mm)

    50400069 100 100 1000

    50400069 125 125 1000

    24