Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

12
Annex_A PAX SOPHO IS3030 SITE TEST AND COMMISSIONING PROCEDURE

description

PAX Commissioning Protocol

Transcript of Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

Page 1: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

Annex_A

PAX SOPHO IS3030 SITE TEST

AND COMMISSIONING PROCEDURE

Page 2: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

Table of Contents

1 INTRODUCTION.....................................................................................................................................5

2 REFERENCE DOCUMENTS/DRAWINGS...........................................................................................5

3 REFERENCE STANDARDS..................................................................................................................5

4 TEST EQUIPMENT.................................................................................................................................5

5 VISUAL INSPECTION............................................................................................................................6

6 PANEL 48 VDC POWER SUPPLY CHECK.........................................................................................6

7 FUNCTION TEST....................................................................................................................................6

7.1 TEST SET-UP.................................................................................................................................6

7.2 FUNCTIONAL TESTS FOR PAX IS3030...................................................................................................7

7.2.1 AUTOMATIC RING-BACK...................................................................................................................7

7.2.2 CALL FORWARDING.........................................................................................................................7

7.2.3 ENQUIRY AND TRANSFER..................................................................................................................7

7.2.4 INTRUSION...................................................................................................................................7

7.2.5 ADD-ON CONFERENCE.....................................................................................................................7

7.2.6 SET DON’T DISTURB/RESET DON’T DISTURB..........................................................................................8

7.2.7 EDIT TELEPHONE NUMBER................................................................................................................8

7.2.8 FOLLOW ME.................................................................................................................................8

7.2.9 CAMP ON BUSY.............................................................................................................................8

7.2.10 COMMON ABBREVIATED DIALING........................................................................................................8

7.2.11 EXTENSION GROUP.........................................................................................................................8

7.2.12 CALL PICKUP.................................................................................................................................9

7.2.13 AUTOMATIC ALTERNATIVE ROUTING......................................................................................................9

7.2.14 CALLING LINE IDENTIFICATION............................................................................................................9

7.2.15 FORCED RELEASE............................................................................................................................9

7.2.16 SYSTEM RESTART...........................................................................................................................9

7.3 SIGNAL CHECKS FOR PAX IS3030......................................................................................................9

7.3.1 EXT. CALL IN &OUT THROUGH LOOP TRUNK...........................................................................................9

7.3.2 EXT. CALL IN &OUT THROUGH E&M TRUNK.........................................................................................10

7.3.3 EXT. CALL IN &OUT THROUGH DIGITAL TRUNK.......................................................................................10

7.4 CHECK “LOCAL CONFIGURATION”FROM MANAGEMENT TOOL.....................................................................10

7.5 DEMONSTRATION OF ALARMS..........................................................................................................11

7.5.1 MINOR ALARM............................................................................................................................11

7.5.2 MAJOR ALARM............................................................................................................................11

7.6 VERIFICATION OF THE VOICE TRANSFER WITH KHARIAN AND MANGLA...........................................................12

7.6.1 EXT. CALL IN &OUT THROUGH E&M TRUNK BETWEEN NBE AND MANGLA....................................................12

7.6.2 EXT. CALL IN &OUT THROUGH LLES BETWEEN NBE AND KHARIAN............................................................12

Page 3: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

LIST OF ABBREVIATIONS

ALC Analogue subscriber

ATU 4W E&M trunk card

DTU-G E1 digital trunks card

DTX Digital subscribers

E1 2048M speed link

EM Ear & mouth

EXT Subscriber

INFO Information

ISG VOIP card

LAN Local Area Network

PAX Private Automatic eXchange

PC Personnel Computer

PLC Power Line Carrier

PMC-SIC Central processor unit

PSU-MLD Power Supply Unit

QSig Q signal accord with Q.921, Q.931 protocol.

Page 4: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

1 INTRODUCTION

The present document defines the test procedure for the PAX system installed

under the project.

The supplied equipment is SOPHO iS3030

2 REFERENCE DOCUMENTS/DRAWINGS

The following documents shall be referenced for site tests and commissioning of

the PAX(IS3030).

3

REFERENCE STANDARDS

The following standards shall be applied for site tests and commissioning of the

PAX(IS3030)

IEC60950 2005Information technology equipment - Safety - Part 1 General requirements

IEC/PAS 62163 External visual test method

YD/T 954-1998 requirements and test method of digital stored program control

dispatching equipment

4 TEST EQUIPMENT

All test instruments used for the testing shall have a valid calibration date.

The test instruments are listed hereafter:

Computer with updated IS3030 management system

Standard multimeter

Two telephone handsets

System configuration diagram Telecom system NBE-212-02-002_R11Circuit diagram drawing Telecommunication system PLC,PAX and PABX

NBE-212-04-002_R5

Description of Communication Interface to NPCC NBE-204-02-005_R4Arrangement Drawing Telephone System NBE-212-03-001_R2Parts List–Telephone System of PAX and PABX NBE-212-05-001_R0

Page 5: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

One Executive Telephone Set

1 Brucelle tool

6 Ethernet cable

4 PAX subscriber cable

5 VISUAL INSPECTION

Referring to drawings as listed, carry out a visual inspection of the equipment to

ensure completeness of installation, conformity of assembly, and readiness for tests

and commissioning. Inspections shall cover the following items:

Completeness of installation

Painting of enclosure

No corrosion inside control box

Check of all rating plates

Identification tags of wiring and cabling

Identification of cores including spares

Earthing and shielding

Check of core termination against drawings

Equipment properly cleaned and free from dust

6 PANEL 48 VDC POWER SUPPLY CHECK

To proceed

Feed PAX power terminal with DC 48V

With voltmeter in DC mode, measure 48V DC on input terminal block. Record

result in commissioning Protocol.

7 FUNCTION TEST

7.1 Test set-up

For the link tests the test setup shall comprise PAX, PLC in Station A connected to PAX, PLC in

remote Station B through overhead transmission line as shown below:

Page 6: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

7.2 Functional tests for PAX IS3030

As following drawing connect the PAX and phones.

7.2.1 Automatic ring-back

Busy: After telephone dial when hearing busy tone, dial “5” directly, then hang off.

No answer: After telephone dial when there is no answer, first press “R” and press

“5”, then hang off.

7.2.2 Call forwarding

From management system set as following input through PC:

CHCALF:0,XXXX,YYYY;Call forwarding when no answer:

CHCALF:1,XXXX,YYYY;Call forwarding when busy

Called EXT number is XXXX, if this phone is busy or no answer that the calling will

automatically forward to EXT YYYY.

7.2.3 Enquiry and transfer

EXT A call EXT B, EXT B press “R”, dial EXT C number, then EXT B hang off. EXT A

can communicate with EXT C.

Page 7: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

7.2.4 Intrusion

High Priority EXT A call low Priority EXT B, when the line is busy, EXT A press “1”,

then can insert the communication, become 3 party.

7.2.5 Add-on conference

EXT A first dial the EXT B number, when the EXT B answers, EXT A press “R” and

“*30”, then dial EXT C number, after EXT C answers, at last again press button R.

The conference can begin.

7.2.6 Set Don’t disturb/Reset Don’t disturb

From management system set as following input through PC:

ASFACM:24, xxxx: Turn on function:

ERFACM:24, xxxx: Cancel DND function:

Setting EXT number xxxx as DND.

7.2.7 Edit telephone number

From management system set as following input through PC:

CHDNRC:XXXX ; delete old number. XXXX is A slot B port old number.

CHDNRC: YYYY, 11, A, B; add new number. YYYY is A slot B port new

number.

7.2.8 Follow me

From management system set as following input through PC:

Turn on function: ASFACM:7,XXXX

EXT A number is XXXX, on the EXT A phone press “*21”, and EXT B number. Later

all call to EXT A will transfer to EXT B, EXT B is ringing.

7.2.9 Camp on busy

From management system set as following input through PC:

ASFACM:30,XXXX ; Turn on function:

XXXX is called EXT number. Telephone A call EXT XXXX, if EXT XXXX is busy, then

the telephone A will be on line for waiting, when EXT XXXX hang off, the telephone A

can build communication with EXT XXXX.

7.2.10 Common Abbreviated Dialing

From management system set as following input through PC:

ASBLCK:0,XXX,1,3,23

XXX is abbreviated number, the fourth digit “3” is length of number.

Page 8: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

CHABNR:XXX,YYYY,1 YYYY is original number.

7.2.11 Extension group

From management system set as following input through PC:

CRGRP:0001,18 ; add group (group number 0001)

ASGRPM:0001,XXXX,0,Y ; add group members:

(EXT number XXXX) (group serial number Y )

In a group all EXT can have function such as call pick up.

7.2.12 Call pickup

Within a group, EXT A is ringing, EXT B press ”*41” and EXT A number, then EXT B

can communicate with incoming phone.

7.2.13 Automatic alternative routing

EXT A call EXT B via some trunk, if this trunk is busy, then this call will go another

trunk to call EXT B.

7.2.14 Calling line identification

On phone will display caller’s information, date and time

7.2.15 Forced release

From management system set as following input through PC:

FRCOUT :11,A,B ;

SETINS:11,A, B;

A is slot number, B is port number

A slot B port can use again.

7.2.16 System Restart

From PC connect PAX Remote desktop software, enter PAX system, run Services

program, select IS3000 SIP@NET Service, press Restart the service

7.3 Signal checks for PAX IS3030

As following drawing connect the PAX and phones.

Page 9: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

7.3.1 EXT. call in &out through loop trunk

EXT A call EXT B through 2W loop trunk.

For example,

loop trunk access code is X1, EXT A number is X2, EXT B number is X3,

EXT A dial X1+X3, then EXT A can talk EXT B.

7.3.2 EXT. call in &out through E&M trunk

EXT A call EXT B through E&m trunk.

For example,

E&M trunks access code is X1, EXT A number is X3, EXT B number is X4,

EXT A dial X1+X3, then EXT A can talk EXT B.

7.3.3 EXT. call in &out through digital trunk

EXT A call EXT B through digital trunk.

For example,

Digital access code is X1, EXT A number is X2, EXT B number is X3,

EXT A dial X1+X3, then EXT A can talk EXT B.

7.4 Check “Local Configuration”from management tool

From management system set as following input through PC:

DISHLF:11 , then will display PAX hardware information as following:

Page 10: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

DIBRDS:11,1 then will show No.1 slot board information

DIBRDS:11,3 then will show No.3 slot board information

7.5 Demonstration of Alarms

From management system set as following input through PC:

7.5.1 Minor alarm

DIMINA: then will show minor alarm as following:

In this example there is minor alarm.

7.5.2 Major alarm

Page 11: Annex_A PAX SOPHO iS3030 Site Test and Commissioning Procedure

DIMAJA:then will show major alarm as following:

In this example there is no major alarm.

7.6 Verification of the voice transfer with Kharian and Mangla.

7.6.1 EXT. call in &out through E&M trunk between NBE and Mangla

NBE PAX E&M terminal connects to NBE PLC E&M terminal. Mangla PAX E&M

terminal connects to Mangla PLC E&M terminal. NBE and Mangla PLC connect

through overhead transmission line.

EXT A in NBE dial the E&M trunk access code, then dial the EXT B number in

Mangla. When EXT B answer, then the communication can be built.

7.6.2 EXT. call in &out through LLEs between NBE and Kharian

In Kharian, the LLEs phone will connect to PLC FXS terminals, NBE PAX FXS

terminal connects to NBE PLC FXO terminal. NBE and Kharian PLC connect

through overhead transmission line.

EXT A in NBE dial the EXT B number in Karian. When EXT B answer, then the

communication can be built.