Andrews2™ Appliance. "The New Generation" Straight-Wire Appliance
-
Author
ortho-organizers -
Category
Documents
-
view
66 -
download
6
Embed Size (px)
description
Transcript of Andrews2™ Appliance. "The New Generation" Straight-Wire Appliance
Andrews ApplianceThe New Generation Straight-Wire Appliance
2
Orthodontic science realizedThe Andrews2 Appliance has tooth guidance built into the brackets rather than into archwires. It is based on recognition of the extensive similarities in tooth morphology between individuals with normal teeth, and in the tooth positions of individuals with naturally optimal dentitions. The Andrews2 Appliance exploits these similarities by utilizing special design features that minimize wire bending while enhancing ease-of-use. Building upon the original Straight-Wire Appliance, the Andrews Foundation has developed an improved appliance system which is a result of 20 years of research and development. Ortho Organizers is the proud, exclusive manufacturer and distributor of the Andrews2 Appliance. The Company has worked closely with Drs. Larry and Will Andrews to develop the Andrews products to the exact, high-quality specifications every patient deserves.
De-ligation Saddles for easy removal of elastic ligatures
Vertical Scribe to align with crowns facial axis
Occluso-Gingivally Centered Slot for accurate slot targeting
Access Bevels for steel ligature cutters
Rounded Tie-Wing Corners for patient comfort
Instrument Channel for bracket positioning control
bracket sitingFrontal Perspective: The vertical midline scribe of the bracket is to be superimposed over the facial axis of the crown. The tie-wings sides are to be parallel to the facial axis of the clinical crown. The bracket is to be centered occlusogingivally on the facial axis of the clinical crown. Lateral Perspective: The mid-transverse planes of the crown and slot will be symbiotic when the base point of the bracket is sited on the crowns FA point.
Mid-Frontal Plane of Slot Slot Point
Mid-Frontal Plane of Crown
Mid-Transverse Plane of Crown and Slot
Facial Axis of the Clinical Crown Mid-Transverse Plane of Crown FA Point
Base Point & FA Point
2
Scientific data Quality constructionThe Andrews2 Appliance is manufactured at Ortho Organizers headquarters in Carlsbad, CA ensuring exact precision. Experts conduct quality assurance inspections, and the latest technologies are used throughout the manufacturing process. The appliance is made through the Metal Injection Molding (MIM) process, which is an advanced technology used for the manufacturing of complex metal products. MIM translates into rounded contours, and other complex structures that machined and cast brackets may not be able to duplicate.
Access Bevels for steel ligature cutters Generous Tie-Wing Undercuts for ease of ligation and space for multiple auxiliaries Contoured Slot Edges Mesial-Distal Stem 90 to Slot to align auxiliary rotation devices with archwire Compound-Contoured Base and Pad Horizontal and vertical base contours match the curvature characteristics of each tooth type for an optimal fit
Rounded Post for patient comfort (optional) 80-Gauge Micro-Etched Bondable Mesh Pad offers proven bond adhesion Color ID Dot for ease of bracket identification
Wider Pad on Lower 5s offers greater bond strength and a weld option
Instrument Groove for precise molar placement Smooth Hook for patient comfort
Pad width allows the molar to be bonded or welded Convertible Cap for ease of 2nd molar access
3
andrews 2 brackets offer unique convenience features
The instrument channel is wider at the center of the bracket to allow a carver instrument to finely adjust and control bracket positioning.
The de-ligation saddles allow for easy removal of elastic ligatures. The design is a scoop out of the bracket stem above and below the archwire slot which allows access for an explorer type instrument.
The stem of the bracket body is positioned 90 to the archwire slot which allows for a more aligned rotational force of an auxiliary wedge against the archwire.
Access bevels on each of the four tie-wings allow ease of removal of metal ligatures from any angle.
4
andrews 2 bracket identification Chart standard bracketsU7R U6R u5r u4r u3ru2Ru1r u1lu2l u3l u4l u5l U6L U7L
L7R
L6R
l5r l4r l3r l2Rl1r l1ll2l l3l l4l l5l
L6L
L7L
Andrews2 standard PrescriptionMaxillaryNote Standard Part Number Tooth Central Inclination +7 Angulation +4 Counter Rotation 0 .022 L 712-800 .022 R 712-801
Tooth Lateral +4 +8 0 712-802 712-803 Standard
Tooth Cuspid -7 +8 0 712-804 712-805 Standard
Cuspid Hk
-7
+8
0
712-804HK
712-805HK
Standard
Tooth 1st Bicuspid -7 +2 0 712-806 712-807 Standard
1st Bicuspid Hk
-7
+2
0
712-806HK
712-807HK
Standard
Tooth 2nd Bicuspid -7 +2 0 712-808 712-809 Standard
2nd Bicuspid Hk
-7
+2
0
712-808HK
712-809HK
Standard
Bracket images are not representative of actual size, or ratio to other brackets.
5
Andrews2 standard PrescriptionMaxillaryTooth 1st Molar Part Number Inclination -10 Angulation +5 Offset 10 Counter Rotation 0 .022 L 712-850 .022 R 712-851 Note Standard
Tooth 2nd Molar -10 +5 10 0 712-852 712-853 Standard
Andrews2 standard PrescriptionmandibularTooth Anterior 1/2 Part Number Inclination -6 Angulation +1.5 Counter Rotation 0 .022 L 712-810 .022 R 712-811 Note Standard
Tooth Cuspid -11 +3 0 712-812 712-813 Standard
Cuspid Hk
-11
+3
0
712-812HK
712-813HK
Standard
Tooth 1st Bicuspid -17 +2 0 712-814 712-815 Standard
1st Bicuspid Hk
-17
+2
0
712-814HK
712-815HK
Standard
Tooth 2nd Bicuspid -22 +2 0 712-816 712-817 Standard
2nd Bicuspid Hk
-22
+2
0
712-816HK
712-817HK
Standard
Bracket images are not representative of actual size, or ratio to other brackets.
6
Andrews2 standard PrescriptionmandibularNote Standard Part Number Tooth 1st Molar Inclination -30 Angulation +2 Counter Rotation 0 .022 L 712-854 .022 R 712-855
Tooth 2nd Molar -35 +2 0 712-856 712-857 Standard
Bracket images are not representative of actual size, or ratio to other brackets.
andrews 2 archwiresOptimal arches are essential for optimal occlusion. Andrews Archwires have the features needed to treat arches to optimal standards efficiently. .014, .016 Nitanium Super Elastic Wires have flexibility for initial aligning and rotations .014, .016 stainless steel wires have a balance of flexibility and rigidity for initial aligning and leveling .016, .018 stainless steel wires have a balance of flexibility and rigidity for leveling, correcting arch shape, and for mesiodistal translation .018 x .025 Ortholoy-Blue (heat treatable) stainless steel wires are for inclining and fine tuning Flexibility: Arches can be effectively and efficiently treated to optimal standards by using the most appropriate Andrews Appliance prescription in combination with the most suitable Andrews Archwires in terms of flexibility. Shape: The Andrews Archwires are preformed to match the average shape of the 120 non-orthodontic normal study casts used in the Six Keys to Normal (Optimal) Occlusion study. Like any preformed archwire, its shape must be customized to each patients unique anatomy. Length: The overall length can usually be customized with one cut. Pre-Posted Archwire Option: For each arch, the small, medium, and large distances between the posts means one of the 3 will fit 90% of the normal patient population.*7
Orthodontic science realized.
*Call for availability.
andrews 2 archwiresArchwire
nitanium Super elastic archwireAndrews 2 Arch Form Single Pack 10/Pack 112-140 112-141 112-142 112-143 112-144 112-145
stainless steel archwireAndrews 2 Arch Form Single Pack 10/Pack 112-100 112-101 112-102 112-103 112-104 112-105
ortholoy-blue archwireAndrews 2 Arch Form Single Pack 10/Pack
Arch Form Packaged .014 Upper .014 Lower .016 Upper .016 Lower .018 Upper .018 Lower
.017 x .025 Upper** .017 x .025 Lower** .018 x .025 Upper .018 x .025 Lower
112-146 112-147
112-172 112-173
Archwire
stainless steel PRE-POSTED ARCHWIREAndrews 2 Arch Form Single Pack 10/Pack
Archwire
ortholoy-blue PRE-POSTED ARCHWIREAndrews 2 Arch Form Single Pack 10/Pack
Arch Form Packaged .016 Pre-Posted Upper 33 mm posted 37 mm posted 41 mm posted .016 Pre-Posted Lower 24 mm posted 28 mm posted 32 mm posted .018 Pre-Posted Upper 33 mm posted 37 mm posted 41 mm posted .018 Pre-Posted Lower 24 mm posted 28 mm posted 32 mm posted
Arch Form Packaged .018 x .025 Pre-Posted Upper
112-106 112-116 112-126
33 mm posted 37 mm posted 41 mm posted .018 x .025 Pre-Posted Lower
112-174 112-178 112-182
112-107 112-117 112-127
24 mm posted 28 mm posted 32 mm posted
112-175 112-179 112-183
112-108 112-118 112-128
112-109 112-119 112-129
Andrews Archwires are great for use with the Andrews Appliance.
Andrews Arch Form
8
single patient kits/introductory kitPart Number 0.022 Single Patient Kits/Introductory Kit with Molars U/L 7x7 Rx #5 Standard (Hks on 3s, 4s, 5s) U/L 7x7 Rx #5 Standard (HKs on 3s) Carousel 712-915 712-915HK Q-Packs U/L 7x7 Rx #5 Standard (Hks 3s, 4s, 5s) U/L 7x7 Rx #5 Standard (Hks 3s) 712-915Q 712-915HKQ Andrews 2 Bracket Kit Andrews 2 Bracket Organizer Kit (empty) 712-000 Andrews Books Straight Wire, The Concept, and Appliance 712-BOOK1 Andrews 2 Typodonts Andrews 2 Typodont Standard 631-712S 631-712T Andrews 2 15X Model Andrews 2 15X Bracket Model 631-712X
Andrews2 Prescription
Andrews 2 Typodont Translation
Part Number 0.022 Single Patient Kits/Introductory Kit without Molars U/L 5x5 Rx #5 Standard (Hks on 3s, 4s, 5s) U/L 5x5 Rx #5 Standard (HKs on 3s) Carousel 712-905 712-905HK Q-Packs U/L 5x5 Rx #5 Standard (Hks 3s, 4s, 5s) U/L 5x5 Rx #5 Standard (Hks 3s) 712-905Q 712-905HKQ
9
The Andrews2 fully programmed Appliance systemScientific Effective EfficientThe Andrews2 Appliance is comprised of both standard and translation brackets. Teeth that do not require translation are assigned standard brackets. Teeth that need to be translated mesially or distally are assigned translation brackets minimum (T1), medium (T2), or maximum (T3) depending on the distance the teeth need to be translated. Andrews2 Brackets can be prescribed individually or by prearranged set. There are 11 sets for the maxillary arch and 10 for the mandibular arch. Arch correction efficiency is maximized when the most appropriate brackets are prescribed, properly sited, and the most suitable archwires and forces are applied. When used as such it becomes a fully-programmed appliance. Properly prescribed and sited Andrews2 Brackets will assist you in getting where you want to go as fast as is biologically possible, with the least amount of effort.
10
translation bracketsWhen teeth require mesial or distal bodily movement, translation brackets have significant advantages over standard brackets. Translation brackets include all of the qualities and features of standard brackets, plus a power arm and built-in counter-angulation and counter-rotation. Collectively, the width of the brackets, length of the power arms, and the counter-angulation direct forces close to or at the tooths center-of-resistance. This allows for effective bodily movement and the right amount of over correction (angulation and rotation) when using flexible archwires and sliding mechanics.
Power Arm for delivering force toward the tooths center of resistance
Translation Identification Dots make it easy to identify the specific translation bracket
Counter-Angulation adds counter-movements during translation and the right amount of over correction 2nd Pre-Molar Identifier
Counter-Rotation adds rotational control during translation and slightly over corrects Translation 1st Molar
Andrews 2 Translation brackets help to deliver forces to the tooths center-of-resistance.
11
Andrews2
Straight-Wire Appliance SystemThe Andrews2 Straight-Wire Appliance System is composed of prearranged sets of brackets correlated with commonly diagnosed arch discrepancies. There are 11 maxillary and 10 mandibular sets. The bracket sets are combinations of 5 different types of brackets:S Standard Bracket T1 Minimum Translation Bracket T2 Medium Translation Bracket T3 Maximum Translation Bracket T4 Maxillary Molar 7 mm Overjet Bracket
The bracket sets found on this page and the following page are for both upper and lower arches, except where noted. Arch Discrepancy category Inventory Archquadranttreatment plan Percentdiscrepancy
2%
(+)9-14 mm
Translate posterior teeth mesially 4.5 to 7 mm per quadrant. (Rx #1)
SPACED
3%
(+)5-8 mm
Translate posterior teeth mesially 2.5 to 4 mm per quadrant. (Rx #2)
5%
(+)1-4 mm
Translate posterior teeth mesially 0.5 to 2 mm per quadrant. (Rx #3)
2%
0 mm (Ext.)
CLASSIC
Non-extraction condition with premolar extractions. Translate posterior teeth mesially 4.5 to 7 mm per quadrant. Useful when opposing arch needs reciprocal resistance. (Rx #4)
30%
0 mm
No mesial or distal translation needed. (Rx #5)
12
Arch Discrepancy category
Inventory Archquadranttreatment plan Percentdiscrepancy
30%
(-) 1-5 mm
Move posterior teeth distally 0.5 to 2.5 mm per quadrant. (Rx #5)
7%
(-) 6 mm
Extract 2nd premolars and close space reciprocally. (Rx #6)
5%
(-) 7-8 mm
Extract 1st premolars and close space reciprocally. (Rx #7)
CROWDED
5%
(-) 9-10 mm
Extract 1st premolars. Translate canines distally 4.5 to 5 mm per quadrant. Translate posterior teeth mesially 2 to 2.5 mm per quadrant. (Rx #8) Extract 1st premolars. Translate canines distally 5.5 to 6 mm per quadrant. Translate posterior teeth mesially 1 to 1.5 mm per quadrant. (Rx #9)
4%
(-) 11-13 mm
4%
(-) 14 mm
Extract 1st premolars. Translate canines distally 7 mm per quadrant. (Rx #10)
3%
(-) 14 mm (Upper Ext. Only)
Extract upper 1st premolars only. Translate canines distally up to 7 mm per quadrant. Maxillary molars finish 7 mm mesial to Key 1. (Rx #11)13
andrews 2 bracket identification chart
Maxillary Translation Brackets
T4 T3 T2 T1 U7R U6R u5r u4r u3r
T4 T3 T2 T1
T4 T3 T2 T1 u3l u4l u5l U6L U7L
T4 T3 T2 T1
Color-coded ID for easy reference
U7R
U6R
u5r u4r u3ru2Ru1r u1lu2l u3l u4l u5l
U6L
U7L
Standard Brackets
L7R
L6R
l5r l4r l3r l2Rl1r l1ll2l l3l l4l l5l
L6L
L7L
mandibular Translation Brackets
L7R T1 T2 T3
L6R
l5r
l4r
l3r T1 T2 T3
T1 T2 T3
l3l
l4l
l5l
L6L
L7L T1 T2 T3
2nd premolar identifier
14
Andrews2 translation PrescriptionMaxillaryNote T2 Part Number Tooth Cuspid PA Inclination -7 Angulation +10 Counter Rotation 2M .022 L 712-804T2 .022 R 712-805T2
Cuspid PA
-7
+11
3M
712-804T3
712-805T3
T3
Tooth 1st Bicuspid PA -7 +4 2M 712-806T2 712-807T2 T2
Tooth 2nd Bicuspid PA -7 +1 1D 712-808T1 712-809T1 T1
2nd Bicuspid PA
-7
0
2D
712-808T2
712-809T2
T2
2nd Bicuspid PA
-7
-1
3D
712-808T3
712-809T3
T3
Bracket images are not representative of actual size, or ratio to other brackets.
15
Andrews2 translation PrescriptionMaxillaryTooth 1st Molar Part Number Inclination -13 Angulation +4 Offset 10 Counter Rotation .022 L 1D 712-850T1 .022 R 712-851T1 Note T1
1st Molar
-14
+3
10
2D
712-850T2
712-851T2
T2
1st Molar
-15
+2
10
3D
712-850T3
712-851T3
T3
1st Molar
-10
0
0
0
712-850T4
712-851T4
T4
Tooth 2nd Molar -13 +4 10 1D 712-852T1 712-853T1 T1
2nd Molar
-14
+3
10
2D
712-852T2
712-853T2
T2
2nd Molar
-15
+2
10
3D
712-852T3
712-853T3
T3
2nd Molar
-10
0
0
0
712-852T4
712-853T4
T4
Bracket images are not representative of actual size, or ratio to other brackets.
16
Andrews2 Translation PrescriptionmandibularNote T2 Part Number Tooth Cuspid PA Inclination -11 Angulation +5 Counter Rotation 2M .022 L 712-812T2 .022 R 712-813T2
Cuspid PA
-11
+6
3M
712-812T3
712-813T3
T3
Tooth 1st Bicuspid PA -17 +4 2M 712-814T2 712-815T2 T2
Tooth 2nd Bicuspid PA -22 +1 1D 712-816T1 712-817T1 T1
2nd Bicuspid PA
-22
0
2D
712-816T2
712-817T2
T2
2nd Bicuspid PA
-22
-1
3D
712-816T3
712-817T3
T3
Part Number Tooth 1st Molar Inclination -30 Angulation +1 Counter Rotation 1D .022 L 712-854T1 .022 R 712-855T1 Note T1
1st Molar
-30
0
2D
712-854T2
712-855T2
T2
1st Molar
-30
-1
3D
712-854T3
712-855T3
T3
Tooth 2nd Molar -35 +1 1D 712-856T1 712-857T1 T1
2nd Molar
-35
0
2D
712-856T2
712-857T2
T2
2nd Molar
-35
-1
3D
712-856T3
712-857T3
T3
Bracket images are not representative of actual size, or ratio to other brackets.
17
Andrews2 translation Prescriptionsingle patient kits/introductory kitPart Number 0.022 Single Patient Kits/Introductory Kit with Molars U/L 7x7 Rx #1 Spaced 9-14 mm U/L 7x7 Rx #2 Spaced 5-8 mm U/L 7x7 Rx #3 Spaced 1-4 mm U/L 6x6 Rx #4 Extraction-4 Classic U/L 6x6 Rx #6 Extraction-5 6 mm 2nd Pre-Molars U/L 6x6 Rx #7 Extraction 7-8 mm U/L 6x6 Rx #8 Extraction 9-10 mm U/L 6x6 Rx #9 Extraction 11-13 mm U/L 6x6 Rx #10 Extraction 14 mm U/L 6x7 Rx #11 Extraction 14 mm Extraction U4 U/L 7x7 T2 Kit (T2s on 3s, 4s, 5s, 6s, 7s) Carousel 712-922 712-912 712-913 712-914 712-916 712-917 712-918 712-919 712-920 712-921 712-91T2 Q-Packs U/L 7x7 Rx #1 Spaced 9-14 mm U/L 7x7 Rx #2 Spaced 5-8 mm U/L 7x7 Rx #3 Spaced 1-4 mm U/L 6x6 Rx #4 Extraction-4 Classic U/L 6x6 Rx #6 Extraction-5 6 mm 2 Pre-Molarsnd
Part Number 0.022 Single Patient Kits/Introductory Kit without Molars U/L 5x5 Rx #1 Spaced 9-14 mm U/L 5x5 Rx #2 Spaced 5-8 mm U/L 5x5 Rx #3 Spaced 1-4 mm U/L 5x5 Rx #4 Extraction-4 Classic U/L 5x5 Rx #6 Extraction-5 6 mm 2nd Pre-Molars U/L 5x5 Rx #7 Extraction 7-8 mm U/L 5x5 Rx #8 Extraction 9-10 mm U/L 5x5 Rx #9 Extraction 11-13 mm U/L 5x5 Rx #10 Extraction 14 mm U/L 5x5 Rx #11 Extraction 14 mm Extraction U4 U/L 5x5 T2 Kit (T2s on 3s, 4s, 5s) Carousel 712-901 712-902 712-903 712-904 712-906 712-907 712-908 712-909 712-910 712-911 712-90T2 Q-Packs U/L 5x5 Rx #1 Spaced 9-14 mm U/L 5x5 Rx #2 Spaced 5-8 mm U/L 5x5 Rx #3 Spaced 1-4 mm U/L 5x5 Rx #4 Extraction-4 Classic U/L 5x5 Rx #6 Extraction-5 6 mm 2 Pre-Molarsnd
712-922Q 712-912Q 712-913Q 712-914Q 712-916Q 712-917Q 712-918Q 712-919Q 712-920Q 712-921Q 712-91T2Q Andrews 2 Bracket Kit 712-930 712-930HK 712-000 Andrews Books
712-901Q 712-902Q 712-903Q 712-904Q 712-906Q 712-907Q 712-908Q 712-909Q 712-910Q 712-911Q 712-90T2Q Andrews 2 Bracket Kit 712-900 712-900HK
U/L 6x6 Rx #7 Extraction 7-8 mm U/L 6x6 Rx #8 Extraction 9-10 mm U/L 6x6 Rx #9 Extraction 11-13 mm U/L 6x6 Rx #10 Extraction 14 mm U/L 6x7 Rx #11 Extraction 14 mm Extraction U4 Only U/L 7x7 T2 Q-PK Kit (T2s on 3s, 4s, 5s, 6s, 7s) Intro Kit with Molars U/L 6x6 30 Case Introductory Kit * (Hks 3) U/L 6x6 30 Case Introductory Kit * (Hks 3,4,5) Andrews 2 Bracket Organizer Kit (empty)
U/L 5x5 Rx #7 Extraction 7-8 mm U/L 5x5 Rx #8 Extraction 9-10 mm U/L 5x5 Rx #9 Extraction 11-13 mm U/L 5x5 Rx #10 Extraction 14 mm U/L 5x5 Rx #11 Extraction 14 mm Extraction U4 Only U/L 5x5 T2 Q-PK Kit (T2s on 3s, 4s, 5s) Intro Kit without Molars U/L 5x5 30 Case Introductory Kit * (Hks 3) U/L 5x5 30 Case Introductory Kit * (Hks 3,4,5)
Straight Wire, The Concept, and Appliance
712-BOOK1 Andrews 2 Typodonts
Andrews 2 Typodont Standard Andrews 2 Typodont Translation
631-712S 631-712T Andrews 2 15X Model
Andrews 2 15X Bracket Model
631-712X
* Call for availability.
18
about Drs. Larry and Will AndrewsDr. Larry Andrews is the inventor of the Straight-Wire Appliance System, discoverer of the Six Keys to Normal (Optimal) Occlusion, and the Six Elements of Orofacial Harmony. In 1989, he authored the textbook Straight Wire, The Concept and Appliance. He is a clinical professor at the University of California at San Francisco, an adjunct professor at West Virginia University, and a visiting professor at Bauru Dental School, University of Sao Paulo, Brazil. Dr. Andrews completed orthodontic training at Ohio State University. He has lectured worldwide about the Six Elements Orthodontic Philosophy, and maintains a private practice limited to orthodontics and orofacial harmony in San Diego, CA.
Lawrence F. Andrews, D.D.S.
Dr. Will Andrews completed orthodontic training at the University of California at San Francisco (UCSF) in 1992. He is a Diplomate of the American Board of Orthodontics, a member of the Edward H. Angle Society of Orthodontists, an assistant clinical professor at UCSF, and an adjunct assistant professor at West Virginia University. Dr. Andrews has lectured worldwide, published articles about the Six Elements Orthodontic Philosophy, and maintains a private practice limited to orthodontics in San Diego, CA.
Will A. Andrews, D.D.S.
Straight Wire
THE CONCEPT AND APPLIANCEThe author, Lawrence F. Andrews, D.D.S., discovered the Six Keys to Normal (Optimal) Occlusion, and invented the Straight-Wire Appliance System. Straight Wire, the Concept and Appliance is the quintessential book about the worlds most popular orthodontic appliance concept.
19
Andrews FoundationFor information on courses about the Andrews2 Appliance, contact the Andrews Foundation: In the U.S. 800.799.8952 | Outside the U.S. +(1) 619 224 0866 Website: AndrewsFoundation.org
For more information on Ortho Organizers products and education offerings, please contact us: In the U.S. 888.851.0533 I Outside the U.S. +(1) 760 448 8600 I Canada: CERUM 800.661.9567 To fax an order: 800.888.7244 I To email an order: [email protected] Like us on Facebook: facebook.com/orthoorganizersonfb
ORTHOORGANIZERS.COM 2013 Ortho Organizers, Inc. All rights reserved. PN 999-255 03/13. Trademarks are the property of their respective owners. Patent pending.