AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN...

8
Refinery and Natural Gas Analysis

Transcript of AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN...

Page 1: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

Refinery and Natural Gas Analysis

Page 2: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

2

ENSURE MORE ACCURATE AND EFFICIENT ANALYSIS

Page 3: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

3www.perkinelmer.com/petrochemical

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is critical to the success of these operations. That’s how PerkinElmer can help.

As a global scientific leader and solutions provider to refining and natural gas labs, PerkinElmer's proven technology and experience meets the ever-changing needs of the oil and gas industry. PerkinElmer is committed to the success of your oil and gas sample analysis by providing the instrumentation, consumables, software and services you need for fast, easy and precise testing. The result: better control of your operations and improved product quality.

PerkinElmer understands that keeping a refinery or natural gas testing laboratory running smoothly can be a difficult process. In addition to supplying leading-edge instrumentation, we provide our OneSource® Laboratory Services, the largest team in the industry with over 1600+ engineers globally to assist you. OneSource offers the most comprehensive portfolio of laboratory services, including maintenance and compliance, asset management, instrument disposition, relocation assistance, training and much more.

TAKE CONTROL OF YOUR OPERATIONS

“ We used the knowledge provided by PerkinElmer as a guideline in our lab.”

- IRPC (Integrate Refinery Petrochemical Complex), Thailand

“ For years we have depended on our PerkinElmer refinery gas analyzers for continuous and reliable sample analysis. We have not found another instrument company that can provide a complete solution package combined with fast reliable service support.”

– Large Crude Oil Refiner, United States

Page 4: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

4

Metals Analysis

Testing for metals is an important part of the sample analysis picture. Meeting product specifications is critical to efficient and profitable plant operation as well as assuring safe and reliable use of the products by the end user. The presence of the wrong element or too high a concentration can poison a catalyst or cause unintentional releases into the atmosphere. PerkinElmer offers a wide range of inorganic measurement solutions covering the full range of elements, concentrations and matrices that may need to be analyzed. The new Optima ICP-OES series is built around the market leading design of the Optima platform, it delivers breakthrough performance through a series of cutting-edge technologies that optimize sample introduction, enhance plasma stability, simplify method development and dramatically reduce operating costs.

Material Characterization

A leader in FT-IR and UV/Vis analysis, PerkinElmer has over 65 years of experience to dramatically simplify fuel analysis. Our new FT-IR Spectrometers, Spectrum Two™ and Frontier, take ease-of-use to a new level. With Spectrum Two, you can assure the quality and composition of fuel samples faster and more easily than ever before. Now, operators in the lab or in the field can obtain industry-standard IR results in minutes. Frontier systems can exceed your expectations for your current FT-IR analysis and can also be expanded as your research or analytical goals evolve. The system offers flexible configurations in the near, mid-far and far infrared regions.

Gas Chromatography

Our family of Clarus® GC systems includes innovative features for unmatched flexibility and ease-of-use. Each instrument has been designed to meet the analytical needs, experience level and productivity demands of the user.

To enhance the flexibility and performance of our Clarus Gas Chromatographs, we offer a broad range of sample handling systems, multiple detectors, intuitive interfaces, data management software, and a full complement of accessories and consumables.

We work with consensus groups, such as ASTM, to promote method development with new technology and to ensure all methods are designed to meet your testing requirements. Over

100 different turnkey systems are available. Our PerkinElmer experts will ensure you choose the system that meets your specific analytical needs, from hydrogen to asphalt.

THE RIGHT SOLUTIONS FOR ANY APPLICATION

“ Our PerkinElmer GC Refinery Gas Analyzer (RGA) is a fantastic analyzer, stable, reliable, robust, with traceability. We used the first unit for more than ten years and just bought a new RGA early this year. We never worry about RGA analyzer results, which gives our staff more time to focus on other areas.”

– Bangchak Refinery, Thailand

Page 5: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

5www.perkinelmer.com/petrochemical

Application support and technical training seminars are just more ways we can help keep you up-to-date on industry trends and knowledge. Whether you need help choosing the right columns for your instrument, setting up new methods or installing your accessories, PerkinElmer has a team of trained customer service representatives and experienced field service engineers ready to assist you.

OneSource Laboratory Services

With OneSource Laboratory Services, you have the world’s largest and most respected global service and support network at your disposal. We go beyond maintenance and repair of instrumentation. We incorporate laboratory asset management as part of our customers’ business equation—a partner with proven results in improving efficiencies, optimizing operations and providing cost certainty across the globe. No matter what you need, our team of certified, factory-trained Customer Support Engineers is just a phone call away, 24 hours a day, seven days a week.

Operating in more than 150 countries with more than 400,000 assets currently under care, OneSource offers the most comprehensive portfolio of professional laboratory services in the industry, including complete care programs for virtually every technology and manufacturer. By allowing you to consolidate all your service contracts under a single supplier, and by providing responsive, expert technical advice and support at a moment’s notice, we ensure your instrumentation—and your lab—is running at optimum levels at all times.

Whether it’s care and repair, validation and compliance, asset management and laboratory relocation, software and hardware upgrades or education and training, OneSource is… the ONE you can count on.

PerkinElmer Laboratory Solution Enhancements

To further foster your analysis and enhance your instrument performance, PerkinElmer offers the broadest range of high-end consumables, accessories and technical support for all major companies in the analytical industry. From sample preparation through sample disposition, we offer everything you need to help streamline your laboratory process.

Sample preparation is one of the most critical steps in your analytical procedure. Often accounting for 60% of your timetable, it has a fundamental impact on a wide range of operational parameters. PerkinElmer offers a full line of superior sample preparation tools from Solid Phase Extraction (SPE) columns to sample preparation blocks, which simplify your process and limit errors. Let us help you identify the best solution from the beginning.

Elite columns are ideal for the analysis of non-polar petrochemical samples, such as detailed hydrocarbon analysis, hydrocarbon gases, petroleum oxygenates, petroleum aromatics, fuels, waxes, oils, sulfur compounds, mercaptans and carbon disulfide.

We also offer many different phases for solvents, chemicals, flavors, fragrances, essential oils, air toxins, chlorofluorocarbons, arson analysis, pesticides, hydrocarbons and high-temperature applications.

PerkinElmer’s analytical gas supply solutions go beyond basic gas generators. Our high purity hydrogen generators offer the optimum combination of safe operation, reliability and performance. Utilizing field-proven PEM cell technology, hydrogen is produced on demand from de-ionized water and electricity, at low pressure and with minimal stored volume. Innovative control software allows unrivaled operational safety and reliability. Whether you require ultra-high purity hydrogen for your GC or GC/MS or multiple gases to operate your sophisticated LC/MS instrumentation, we have the right generator you need to best fit your laboratory.

Consumables, accessories and supplies are needed on a daily basis to keep your instruments running smoothly. Whether your laboratory is equipped with SimDis, RGA, NGA, or traditional GC systems, ICP/AA, IR or any other technologies, we can provide you

with the consumables to meet all of your analytical needs. From custom-packed GC-specific column sets, gas standards, routine vials, liners, caps and septa to a full array of sample introduction systems, we have you covered from start to finish.

Laboratory Services

OPTIMIZES OPERATIONS

ENSURES COMPLIANCE

CONTROLS COSTS

Page 6: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

6

KEY TO ANALYZING REFINERY AND NATURAL GAS SAMPLES

The following is a list of some significant refinery and natural gas tests required to ensure that your most critical sample analyses are performed. Instrumentation and compliance methods required for these key applications are also provided, allowing you to quickly and easily determine what you will need to deliver expert analysis for your particular product sample.

Product Application Compliance Methods Instrument

Crude Oil Methanol in Crude D7059 Clarus GC with Swafer™ Technology

Simulated Distillation D7169, D6352 Clarus 580/680 GC with Arnel Solution

Light Hydrocarbons (DHA for Improved SimDis Analysis)

IP PM-DL Clarus GC(s) with Swafer Technology and Arnel Solution

Total Mercury D7623 SMS 100 Automated Mercury Analyzer

Metals Analysis D5708, D5863 Optima™ ICP, NexION™ ICP-MS, PinAAcle AA

Gasoline Benzene and Toluene D3606, D5580 Clarus GC with Swafer Technology with Arnel Solution

Simulated Distillation D2887, D3710, IP 406 Clarus 580/680 GC with Arnel Solution

Detailed Hydrogen Analysis (DHA) D6729, D6730, D6733 Clarus 580/680 GC with Arnel Solution

Oxygenates D4815 Clarus 580/680 GC with Arnel Solution

Aromatics D5580 Clarus 580/680 GC with Arnel Solution

Sulfur Selective Detection D5623 Clarus 580/680 GC with Arnel Solution

Benzene Content D6277 Spectrum Two FT-IR

Benzene, Toluene, and Total Aromatics D5769 Clarus 680 GC/MS

Total Sulfur in Light Hydrocarbons D5453 LAMBDA UV-Vis

Phosphorus Analysis D3231 LAMBDA UV-Vis

Biodiesel Testing D7371, EN 14078 Spectrum Two FT-IR or Frontier FT-IR

Natural GasSaturated Light Hydrocarbons - “Natural Gas Analyzer”

D1945, D1946, D5504, DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976

Clarus 580/680 GC with Arnel Solution. More than 30 options available.

Sulfur D5504 Clarus 580/680 GC with Arnel Solution

Refinery GasConcentrations of the Fixed Gases and Light Hydrocarbons “Refinery Gas Analyzer”

D1945, D1946, D2597, DIN 51872-4, UOP 539, 709

Clarus 580/680 GC with Arnel Solution

Jet Fuel FAME Analysis (Biodiesel) IP 585 Clarus GC/MS or Spectrum Two FT-IR

Simulated Distillation D2887, IP 406 Clarus 580/680 GC with Arnel Solution

Naphthalene Testing D1840 LAMBDA UV-Vis

Naphthas DHA D5134, D6730 Clarus 580/680 GC with Arnel Solution

Metals Analysis D5185 Optima ICP, NexION ICP-MS

Silicon Testing Optima 8300 ICP-OES, NexION ICP-MS

Mercury Testing SMS 100 Automated Mercury Analyzer

LPG Determination of Hydrocarbons D2163 Clarus 580/680 GC with Arnel Solution

Kerosene Simulated Distillation D2887 Clarus 580/680 GC with Arnel Solution

Biodiesel Free and Total Gylcerin D6584, D7371, EN 14078 Clarus GC, Spectrum Two FT-IR or Frontier FT-IR

Phosphorus Testing D4951 Optima ICP-OES

Simulated Distillation D7398 Clarus 580/680 GC with Arnel Solution

FAME Analysis D7371, EN 14078, EN 14103 Clarus 580 GC, Spectrum Two FT-IR with UATR

Trace Metals D4951 Optima ICP

Other Hydrogen Sulfide Analysis in the Vapor Phase D6021 Clarus 580/680 GC with Arnel Solution

Metal Analysis in Lubricants D5185, D5708, D4551, D4628 Optima ICP, PinAAcle AA

Trace Elements in Coal, Coke, and Combustion Residues from Coal Utilization

D6357 Optima ICP, NexION ICP-MS, or PinAAcle AA

Trace Metals in Gas Turbine Fuels D3605 PinAAcle AA

2,6-di-tert-Butyl-p-Cresol and 2,6-di-tert-Butyl Phenol in Electrical Insulating Oil

D2668 Spectrum Two FT-IR

Aromatics in Diesel fuels D6591, IP 391, EN 12916 Flexar™ HPLC

Diesel Engine Oils in T-8 Diesel Engines (Soot Build Up Test)

D5967 Pyris 1 TGA

Carbon, Hydrogen, and Nitrogen in Petroleum Products, Coal, and Lubricants

D5373, D5291 2400 Series II CHNS/O System

Evaporation Loss of Lubricating Oils by the Noack Method

D5800 Pyris 1 TGA

Greenhouse Gas Emissions Reporting for EPA Compliance - Total Carbon Content

Regulatory Requirement: 40 CFR part 98 2400 CHN Series II

Page 7: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

7www.perkinelmer.com/petrochemical

Eth

ano

l

Be

nze

ne

2-B

uta

no

l (I.

S.) To

lue

ne

The combination of capillary columns with the Swafer technology has taken a mature method and improved the quality of data and reduced the run time.

ASTM® Test Method, D3606, is an established method used to determine the benzene and toluene content in gasoline—originally developed to analyze gasoline that did not contain ethanol. Ethanol is now added to modern gasolines to improve combustion efficiency. The presence of large amounts of ethanol in samples may cause co-elution problems with benzene.

Using a PerkinElmer Clarus 680 GC with Swafer microflow technology and capillary columns, data quality and run times have been significantly improved. This approach completely eliminated all chromatographic interference between ethanol and benzene, which improves the quality of the chromatography in general and reduces the analysis time significantly (by 50 – 75%). Swafer technology enables the separation on the precolumn to be directly monitored by a detector—allowed the backflush point to be easily and accurately established.

ENHANCED GASOLINE ANALYSIS BY GAS CHROMATOGRAPHY

IR is a common technique for analyzing fuels. Standard IR tests may include testing for biodiesel, or benzene quantity in the fuel. PerkinElmer has harnessed over 65 years of IR experience to dramatically simplify fuel analysis. With Spectrum Two, you can assure the quality and composition of fuel samples faster and more easily than ever before. With the enhanced technology built into the Spectrum Two platform, you can achieve accurate, dependable answers in even non-laboratory environments. Compact in size and robust, the instrument can be transported to any location, or kept in the lab. Performance is never compromised.

You get the result you need—when you need it.

BlankStd01Std04Std06

NamePathlength (mm): 0.116, Biodiesel Concentration (% m/m): 0.000Pathlength (mm): 0.116, Biodiesel Concentration (% m/m): 2.032Pathlength (mm): 0.116, Biodiesel Concentration (% m/m): 5.027Pathlength (mm): 0.116, Biodiesel Concentration (% m/m): 10.021

Description

1900 15501850 1800 1750 1700 1650 1600

1.0

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

cm-1

A

Mineral diesel

FAME 2%v/v

FAME 10%v/v

FAME 5%v/v

The Spectrum Two FT-IR provides fast and easy analysis of varying FAME concentrations in diesel fuel.

FUEL ANALYSIS BY INFRARED

120

110

100

90

80

70

60

50

40

30

20

10

010 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Sig

nal

Pe

rce

nt

Minutes

Boiling Point Curve

Initial BP

Reference Oil Chromatogram

Final BP

SimDis is considered to be the most important technique in a refinery laboratory. Understanding the boiling range of crude oil, or its fractions, is critical for determining quality assurance, regulatory compliance, refinery process control and physical property predictions. ASTM methods used for SimDis applications have been widely used to obtain reliable and repeatable analysis given the specific parameters of each method.

With the Clarus 680 GC oven, users will have an extremely accurate boiling point curve and see a fast cool down time, which in turn provides higher throughput. The POC injector has no discrimination problems against difficult samples and is extremely easy to maintain and use.

This is an example of a reference oil chromatogram with the calculated boiling point curve. Slices of the chromatogram are taken to determine the boiling point fractions.

With the PerkinElmer 680 GC, SimDis Analysis by Modified ASTM D2887, D6352 and D7169, run times have been reduced by approximately half the time of other manufacturers.

MORE ACCURATE, EFFICIENT CRUDE ANALYSIS BY GAS CHROMATOGRAPHY

% Off BP Temp Valid Window Actual Temp PASS/FAIL

5 477.222 2.778 479.412 PASS10 492.222 2.778 494.062 PASS15 502.222 2.778 502.988 PASS20 510.000 3.333 510.516 PASS25 517.222 3.333 517.864 PASS30 523.889 3.889 524.409 PASS35 530.556 3.889 530.312 PASS40 536.667 4.444 535.990 PASS45 542.222 4.444 541.482 PASS50 548.333 4.444 547.144 PASS55 554.444 4.444 552.923 PASS60 560.000 4.444 558.709 PASS65 566.111 4.444 564.441 PASS70 572.222 4.444 570.116 PASS75 578.333 5.000 576.035 PASS80 585.558 4.444 582.822 PASS85 592.775 5.000 590.307 PASS90 602.222 4.444 599.181 PASS95 615.556 3.889 612.159 PASSFBP 656.111 17.778 643.260 PASS

Page 8: AND EFFICIENT ANALYSIS - PerkinElmer · method development with new technology and to ... DIN 51872-5, GPA 2261, 2177, 2286, 2186, 2165, ISO 6568, 6974-5, 6975, 6976 …

Crude Oil

Heavy Distillate Fuels

Diesel

Jet Fuel

Kerosene

Gasoline

Naphtha

LPG (Liquified Petroleum Gas)

Refinery Gas

Natural Gas

For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs

Copyright ©2011, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009946A_01 Printed in USA

PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USAP: (800) 762-4000 or (+1) 203-925-4602www.perkinelmer.com

COMPLETE SOLUTIONS FOR REFINERY AND NATURAL GAS ANALYSIS

Whether you’re analyzing crude oil, natural gas, or any other associated products in the industry, PerkinElmer offers a full range of instrumentation and proven applications to streamline and simply every stage of your process. With over 60 years in the analytical-measurements business, we deliver the knowledge and experience necessary to ensure your laboratory and business requirements are met.

Analyzing and measuring semivolatile and volatile compounds in finished products and raw materials can be performed quickly, easily and accurately with our turnkey solutions. Designed specifically for today’s most common industry methods, our systems help you optimize operations and ensure complete quality control across a broad range of analyses, including:

• Hydrocarbon Analysis • Simulated Distillation • DHA • Oxygenates • Sulfur • Methanol • Aromatics • Metals • Light Gases • Mercury • Elemental • Naphthalenes • FAMEs • Glycerin

For more information on how we can help you efficiently determine the crucial components in your oil and natural gas samples, visit us at www.perkinelmer.com/petrochemical