DS EUROPE TRANSDUCERS AND INDUSTRIAL ELECTRONICS MICROPROCESSOR PANEL METER SERIE AN-401plus Version 2 Rev. 11 31/05/2007 TECHNICAL MANUAL

Transcript of AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora...

Page 1: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

DS EUROPE

T R A N S D U C E R S A N D I N D U S T R I A L E L E C T R O N I C S

MICROPROCESSOR PANEL METER

SERIE AN-401plus

Version 2 Rev. 11 31/05/2007

TECHNICAL MANUAL

Page 2: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-2 / 20-

DOCUMENT HYSTORY

Hardware version Software version Manual version

MA 401 V.02.05 V 2.0 R1

MA 401 V.02.05 V 2.0 R2

PIT MA V0 V.02.07 V 2.5

PIT MA V0 V.02.07 V 2.6

PIT MA V0 V.02.08 V 2.8

PIT MA V0 V.02.08 V 2.9

PIT MA V0 V.02.08 V 2.10

PIT MA V0 V.02.08 V 2.11

\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc

Notice: The information in this manual is subject to change without notice. DS Europe shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This manual contains information protected by copyright. No part of this manual may be photocopied, or reproduced in any form, or translated without prior written consent from DS Europe.

Page 3: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-3 / 20-

FOREWORD 1. This manual is integral part of the shipment and it is supplied with the Product even if not listed in

the invoice. This manual can also be sent during purchase negotiation on Buyer’s request provided that the Buyer states end application of the Product. Except as expressly request by the Buyer, only one copy of this manual may be attached to shipments consisting of more than one unit of the Product. Additional or updated copies of this document may be found on our web site at the following address: www.dseurope.com

2. The Products, which are the subjects of this manual, are designed and manufactured for general use;

therefore, being not possible to specify limits of use for all applications, the Buyer shall introduce safety measures in order to avoid personal injuries, damages to property or damages due to plants stoppage, etc. In case of use that can cause risk of damages, the Buyer shall immediately advise the Supplier in order that it can suggest safety solutions or can decide to reject the order and not to deliver the Product.

3. AN401 series of instruments are not certified instruments; it is Buyer’s responsibility to check

instrument suitability to the requirements of the specific application. 4. AN401 series of instruments, even when connected to transducers or other equipment, are only parts

of more complex systems and plants; they are sold in thousands per year, for the most different applications which shall meet as many different norms that are not always known to the Supplier. For these reasons, DS Europe is obliged to disclaim all responsibility concerning the use of the instrument; however, a list of the most elementary and basic precautions for the correct use of the instrument is given in this manual. Besides, the need of a complete and specific insurance policy is highlighted, especially when systems and machinery are to be installed in Countries like United States or Canada.

5. AN401 series of instruments are designed and manufactured by DS Europe conforming to the

highest quality standards; the instruments are rugged and designed to the highest possible safety and reliability: limitations and precautions listed in this manual are aimed to draw Buyer’s attention to the importance of avoiding damages.

6. During manufacturing process, AN401 series of instruments are submitted to several intermediate

tests and to a final test including performance test of all functions. Electrical, temperature and mechanical sampling tests are periodically carried out to check conformity of manufactured items to Product specifications.

For the overmentioned it is thereby certified that the delivered Product is completely operating. DS EUROPE S.r.l. Via F. Russoli, 6 20143 MILANO - ITALY Tel. 02 8910142 ( 4 lines ) Fax. 02 89124848 8910145 www.dseurope.com E-mail : [email protected]

Page 4: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-4 / 20-

Summary 1 CE declaration.................................................................................. 5 2 Electrical connection........................................................................ 6

2.1 Rear terminal connections...............................................................................................6

2.2 Power Supply Connection................................................................................................6 2.2.1 Power Supply ...............................................................................................................6

2.3 Connection of 0 to ± 80 mV differential signal input card [I1 option]............................7

2.4 Connection of ± 10 V amplified signal input cards [I4 option] .......................................7

2.5 Connection of 2 wires 4-40 mA or 0-20 mA Input card [I6 option]................................7

2.6 Connection of Start /Stop Input card [I10 option] ...........................................................7

2.7 Connection of 0 to 5 Volt [O1 option] and 0-10 Volt [O2 option] output cards .............8

2.8 Connection of 4-20 mA [O3 option] and 0-20 mA [O4 option] output cards .................8

2.9 Connection of I/O card [D0 option].................................................................................8

2.10 Connection of I/O card [D1 option].................................................................................9

2.11 Connection to external Inputs ........................................................................................10

2.12 Earth connection (CE norms).........................................................................................10

2.13 Connection of (1) RS-232(DB-9) serial port .................................................................11

2.14 Connection of (2) RS-485 (RJ-11bl) serial port ............................................................11 2.14.1 An401plus default serial port.....................................................................................11 2.14.2 RS485 and RS422 line terminator resistor.................................................................12

3 Instrument setup ............................................................................ 12 3.1 How to set parameters....................................................................................................12

4 Operating parameter setting......................................................... 13 5 Analog output setting..................................................................... 14 6 Serial connection setting................................................................ 15 7 Measurement functions ................................................................. 16

7.1 Peak function .................................................................................................................17

7.2 Hold................................................................................................................................17

7.3 Protection .......................................................................................................................17

8 DSENET serial protocol ................................................................ 18 8.1 “R” Command................................................................................................................18

8.2 Timestamp “r ”...............................................................................................................19

9 Sales conditions .............................................................................. 20 9.1 Warranty.........................................................................................................................20

9.2 Damage responsibility ...................................................................................................20

Page 5: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-5 / 20-

1 CE declaration Applied Council’s directives: 89/336/CEE modified by directives 92/31/CEE, 93/68/CEE Conformity to Standards: EMC: EN 50081-2: 1994 - Emissions, General Norm EN 55011 EN 50082-2: 1995 - Susceptibility, General Norm ENV 50140 ENV 50141 EN 61000-4-4 EN 61000-4-2 EN 61000-4-8 ENV 50204 Manufacturer: DS Europe srl Address: via F. Russoli, 6 Milan (Italy) Equipment type: Indicator Conditioner Model: AN401 series Year of registered mark: 2003 The equipment has been tested in the typical installation configuration, as described by the instruction manual of the Product. DS Europe srl certify that the above defined equipment meets the requirements of above mentioned EMC directives. Milan, 12/06/98

DS Europe srl Technical dept.

Page 6: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-6 / 20-

2 Electrical connection

2.1 Rear terminal connections

Figure 1: AN401plus rear view.

2.2 Power Supply Connection

Terminal Description

Power Supply, polarity free

Power Supply, polarity free

EARTH Earth Connection

2.2.1 Power Supply

• From 10.5 to 40 Vdc. • From 9 a 28 Vac.

The power supply generator has to be in position to supply up to 1 W. Please use the EARTH connection, available on the connector, as indicated on paragraph 2.11.

12

34

13

42

5 4 3 2 1

9 8 7 6

CanBus

RS-485

RS-232 INPUT

12345

123456 6

45

3

12

6

45

3

12

6

45

3

12

D C B A

EARTH

RJ-11A

RJ-11B

Page 7: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-7 / 20-

2.3 Connection of 0 to ± 80 mV differential signal input card [I1 option]

2.4 Connection of ± 10 V amplified signal input cards [I4 option]

2.5 Connection of 2 wires 4-20 mA or 0-20 mA Input card [I6 option]

IMPORTANT NOTE: power supply to the current loop transducer, connected to this input card, is the same that powers the instrument.

2.6 Connection of Start /Stop Input card [I10 option]

IMPORTANT NOTE: power supply supplied to the connected magnetostrictive transducer is the same supplied to power the instrument Instrument’s power supply must be:

• Not less than 18 Vdc if connection cable between transducer and AN401 is within 20 mt. • Not less than 24 Vdc if connection cable between transducer and AN401 is within 100 mt. • For longer connections, between transducer and instrument, verify that at the transducer’s

end You can measure a power supply voltage of 18 Vdc minimum.

Terminal Description Note DS Europe color code 1 + Transducer’s signal input WHITE 2 - Transducer’s signal input

from 0 to ± 80 mV GREEN

5 - Power supply to transducer BLACK

6 + Power supply to transducer

+ 5 Vdc power supply: transducers has to be powered with the power supply voltage generated by AN401plus. RED

Terminals 3-4 not connected.

Terminal Description Note DS Europe color code

3 - Transducer signal input YELLOW or BLACK

2 + Transducer signal input

Connect signals from ± 10 V (maximum acceptable voltage is +18 Vdc ) WHITE

6 - Power supply to transducer YELLOW or BLACK

1 + Power supply to transducer

Between Pin 5 and Pin 6 it is available the external Power supply. RED

Terminals 4-5 not connected.

Terminal Description Note DS Europe color code 3 LOOP PLUS + Power supply to transducer RED 6 LOOP MINUS - Power supply to transducer . BLACK

Terminals 1-2-4-5 not connected

Terminal Description DS Europe color code for PCX_ss Magnetostrictive transducer

1 + RTX Blue

2 -RTX Serial receiver (RS-422)

Brown

3 -TXD Yellow

4 +TXD Serial transmitter (RS-422)

White

5 Transducer’s GND power supply Black

6 Transducer’s power supply (AN401 plus has to be powered with +24 Vdc external power supply)

Red

Page 8: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-8 / 20-

To calibrate an AN401plus, connected with a PCX_ss magnetostrictive transducer, follow the general procedures described in the “AN401plus quick start manual” or in chapter 5 of this manual. Calibration or measurement displaying is as for load cells, pressure transducers or other standard transducers.

2.7 Connection of 0 to 5 Volt [O1 option] and 0-10 Volt [O2 option] output cards

2.8 Connection of 4-20 mA [O3 option] and 0-20 mA [O4 option] output cards

2.9 Connection of I/O card [D0 option]

Relays electrical characteristics:

Maximum voltage: 30 Vdc Maximum current: 2 A Maximum power: 1W Operate time: 2 mS.

Fig. 10: Connection of relay board.

Terminal Description 1 Voltage analog output: 0 to 5 Volts (O1 option board) or 0 to 10 Volts (O2 option board). 3 AGND common for 0 to 5 V or 0 to 10 V analog output signal.

Terminals 2-4-5-6 not connected.

Terminal Description 1 3 Wires Current analog output: 4 to 20 mA (O3) or 0 to 20 mA (O4). 2 AGND common for Current analog output: 4 to 20 mA (O3) or 0 to 20 mA (O4).

Terminals 1-4-5-6 not connected.

Terminal Description 1 Relay 1 Normally Closed contact 2 Relay 1 Common contact. 3 Relay 1 Normally Open contact. 4 Relay 2 Normally Closed contact. 5 Relay 2 Common contact. 6 Relay 2 Normally Open contact.

Page 9: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-9 / 20-

2.10 Connection of I/O card [D1 option].

Opto-insulator electrical characteristics

- Maximum DC voltage: 70 Vdc. - Maximum current: 50 mA. - Maximum power: 150mW. - Settling time: 18 µS max.

- Insulation: 3000 Vrms

On the figure above is shown the typical connection to be used with PLC inputs configured in “SINK mode”. This is an OPEN collector configuration with all the emitters connected together and to terminal 5 (AN401 plus, slot A or B). These AN401 plus outputs are internally protected against polarity reversal with protection diodes.

1

2

3

4

5

6

Slot

A o

B

OUTPUT INTERFACE

AN 401 PLUS

RELAY-DPDTI max 50 mA

V_Relè

Schematic for relays to be connected to AN401 plus opto-insulated outputs.

Terminal Description 1 Opto-insulated output 1 (open collector) 2 Opto-insulated output 2 (open collector) 3 Opto-insulated output 3 (open collector) 4 Opto-insulated output 4 (open collector) 5 Common Emitter’s output 6 Not connected

1

2

3

4

5

6

Slot

A o

B

OUTPUT INTERFACE

+24V

+24V

+24V

+24V

24V Common

TIPICAL PLC SINK CONNECTION

AN 401 PLUS

Page 10: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-10 / 20-

2.11 Connection to external Inputs On AN 401 plus are available four opto-insulated inputs. Their behaviour depends from the selected instrument’s operating mode. Please refer to the chosen operating mode. Digital inputs can be connected to the “INPUT” screw terminal.

Terminal Description Note 2 Input 1 ( KEY 1 ) Maximum voltage: +28 Volt 3 Input 2 ( KEY 2 ) Maximum voltage: +28 Volt 4 Input 3 ( KEY 3 ) Maximum voltage: +28 Volt 5 Input 4 ( KEY 4 ) Maximum voltage: +28 Volt 1 EXGND (Insulated ground) -

Fig. 1a: Insulated connection Fig.1b: NOT insulated connection

On overmentioned figures (Fig.1a and Fig.1b) are shown connections to be used for pushbuttons but it is possible to connect: relay, TTL lines, transistors, etc. In order to light-on the LED emitters, internal to the opto-couplers, a voltage ranging from +12 to +28 Vdc must be supplied to each input. Opto-coupler’s electrical characteristics:

• Insulation: 3000 Vrms • Settling time: 18 µS ( max ) • Release time: 18 µS ( max )

2.12 Earth connection (CE norms) In order to obtain the maximum immunity to electrical disturbs, following are some recommendations:

• Power supply common must be connected to earth. • If AN401 plus is powered by a power supply separated from the rest of the machine,

connect the “EARTH” screw terminal to the nearest earth connection (avoid earth loops or earth connections disturbed by high power devices).

• When connecting signal lines from AN401 plus (analogue outputs, RS232 serial lines, etc) please remember that they are referred to earth, in order to avoid the creation of earth loops

• Best condition is obtained when all commons (signal and power supply) are connected to earth at the same point (star connection).

• Avoid wiring any input/output cable, directed to AN 401, with high power cables.

If the application is free from electrical disturbs, Earth connection may be avoided.

1

2

3

4

5

INPUTEXGND

KEY1

+24Vdc

123

1

2

3

4

5

INPUTEXGND

+24Vdc

KEY2

KEY3

KEY4

KEY1

KEY2

KEY3

KEY4

EAR

TH

Page 11: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-11 / 20-

2.13 Connection of (0) RS-232(DB-9) serial port Communication serial port used, for its flexibility, for configuration and for reading of measurements in an ambient not to noisy, from the electrical point of view (induced and radiated disturbs), and with a serial connection cable not longer than 3 meters (baud rate can be lowered, in order to optimize serial connection for longer connection lines).

Instrument Computer TX ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯> RX RX <⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ TX GND ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ GND

Most common connection to be used to connect RS 232 connection between AN401plus and PC compatible computers are (serial straight cable):

AN 401 Plus - RS 232 Computer Female 9 pin connector 9 pin connector 25 pin connector TX 2 2 2 RX 3 3 3 GND 5 5 7

2.14 Connection of (1) RS-485 (RJ-11bl) serial port

RJ – 11b Cable color code Description DS Europe Mod. 658-5-X serial converter 1 Brown Not connected - 2 White Data + ( A ) 5 3 Red Data – ( B ) 4 4 Blue GND 1

2.14.1 An401plus default serial port. Settings are: 1. Data bit = 8 2. Parity = None 3. Stop bit = 1 4. Flux control = None

Page 12: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-12 / 20-

2.14.2 RS485 and RS422 line terminator resistor

MULTI DROP connections, like RS485 and RS422, require having a resistance applied at both ends of the communication line (if not yet present inside the connected devices); one is to be placed in parallel to the last AN401plus and one on the PLC or computer on the other end. AN401plus has no internal resistance for RS485 or RS422 but It can be applied under customer’s request. This resistor has to be 120 Ohm ¼ Watt. This resistance is to be applied solely on the last AN401plus of the serial net, in order not to lower, too much, the overall line impedance (fig.11).

3 Instrument setup

3.1 How to set parameters This chapter describes the sequence to be used to set AN401plus, as working parameters and It is valid for all of Its different menus. All different operational modes share the same sequence to set the desired values or parameters, or levels.

Page 13: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-13 / 20-

4 Operating parameter setting

Page 14: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-14 / 20-

5 Analog output setting

Note: valid only if an analog output card is installed into AN401plus. Analog output card is active for all operating modes. DMODE command allows setting analog output in the following ways: DMODE = 1 DMODE = 0

Current analog output behavior can be set in the same way.

Page 15: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-15 / 20-

6 Serial connection setting

BAUD set value

Serial data transmission rate

(baud) Default values

0 600 Baud rate 4 (9600 baud) 1 1200 Address 0 2 2400 Com 0 3 4800 4 9600 5 19200 6 38400 7 57600

Table 1: Available baud rate values.

Page 16: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-16 / 20-

7 Measurement functions

By pressing pushbutton “ ” Alarm levels configuration menu is entered.

Alarm levels menu Parameter Description Default Possible values LEV0 Level 0 switching value 1000 ±99999 HIS0 Level 0 hysteresis 0 from 0 to 50 SET0 Level 0 configuration 0 See SET parameter LEV1 Level 1 switching value 1000 ±99999 HIS1 Level 1 hysteresis 0 from 0 to 50 SET1 Level 1 configuration 0 See SET parameter LEV2 Level 2 switching value 1000 ±99999 HIS2 Level 2 hysteresis 0 from 0 to 50 SET2 Level 2 configuration 0 See SET parameter LEV3 Level 3 switching value 1000 ±99999 HIS3 Level 3 hysteresis 0 from 0 to 50 SET3 Level 3 configuration 0 See SET parameter

SET parameter

Working MODE Function 0 Relay disabled 1 Relay activates on GROSS measurement. 2 Relay activates on NET measurement. 3 Relay activates on Positive peak measurement. 4 Relay activates on Negative peak measurement.

• NET • GROSS

Measures

• TARE Display • NET = (GROSS – Dynamic ZERO)

• Push button C • Set Dynamic ZERO = Measured value • Push button E • When pressed display shows Dynamic ZERO value • Push button • Level setting menu

Keyboard

• Push button • When pressed display shows GROSS • Key 1 • Set Dynamic ZERO = Measured value • Key 2 • Hold of the measurement • Key 3 • Keyboard lock / protection enforcement

Inputs

• Key 4 • If active it stores the measured peak value • RL0 • Level 0 functions • RL1 • Level 1 functions • RL2 • Level 2 functions

Relays

• RL3 • Level 3 functions

Page 17: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-17 / 20-

7.1 Peak function The peak function stores and displays the maximum value reached by transducer’s signal when the KEY4 rear contact is activated (see table 1) Key 4 rear contact has to be kept closed as long as peak value is to be displayed (see chapter 2.10). When this function is active, the leftmost LED dot under the minus sign is powered on. The stored peak value can be zeroed by: • Pressing C (ESC) push button on AN401plus front panel; • Closing KEY2 terminal on rear terminal panel (see chapter 2.10).

7.2 Hold Hold function freezes the measurement actually shown on the display, until it is disabled. All function measurements are freezed and it is activated by closing KEY 1 contact (see chapter 2.10). To de-activate this function open the contact

7.3 Protection AN401plus has a protection system that prevents not authorized personnel to tamper with the instrument settings, nor with programming menus. To activate protection, connect KEY3 as for chapter 2.10. When protection is enabled it is not possible to access to start-up programming menus. In order to apply authorized changes to the instrument, remove the connection on KEY3. Protection may be applied solely if an O5 I/O card is installed on slot C

Page 18: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-18 / 20-

8 DSENET serial protocol NOTE: for protocol compactness it was decided to use only one character to address an instrument. After the first ten numbers, address numbering continues with alphabet letters, thus A means 10, B means 11 and so on until Z that means 35.

8.1 “R” Command Command “R” allows to request, from a remote computer, the measure acquired by AN401plus within the active operating mode. The command argument defines which measures is requested to the instrument and is independent from the actual measurement function. Argument of the R command is an ASCII character and may assume the following values:

Command format @ ID R Index ( ind ) CR

Where:

ID = address of the connected AN401plus (in case only one AN401 is connected, by sending “?” the instrument will always reply). The identifier shall be a character in the set 0-9 or A-Z; ID can also be the character “?” if a message is to be sent to an instrument the identifier of which is unknown.

• R = read measure command. • Index = 1 digits numeric index indicating to AN401plus which measure is requested; see “Ind” column.

Note: RO means that the parameter is Read Only and cannot be modified by user. • CR = “Carriage Return” must close every message sent to the instrument and is represented by an ASCII

character. Ind Prot Parameter Symbol

0 RO Measured value A/D converter points VAL_AD 1 RO Filtered measured value A/D converter points VAL_ADF 2 RO Gross value in engineering units VAL_UMEC 3 RO Net value in engineering units

(GROSS–ZDYN) VAL_NZDYN

4 RO Net value in engineering units (GROSS–TARE)

VAL_NTARE

5 RO Peak value (only for operating mode 7) with Kg engineering units VAL_ROTT 6 RO Peak value (only for operating mode 7) with N engineering units VAL_ROTTN

Example: Measured value, in A/D converter points, is requested with @?R0CR. Reply to command “R”: xxRyyyyyyyy Where: xx = sent command index ( Ind ): 2 digits. R = reply to command “R”: 1 digit. Yyyyyyyy = measured value: 8 digits.

Page 19: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-19 / 20-

8.2 Timestamp “r ” To obtain, from AN401plus, measured value with timestamp reference send command “r”. Timestamp is obtained from an incremental counter related to the measure performed by AN401plus and its value is ranging from 0 to 65535; when maximum is reached It restarts from zero. Working of “r” command is like “R” command (same command structure). Example: To request measured A/D converter value, send the following string: @?r0CR. Reply to command “r”: xxRyyyyyyyyzzzzz Where: xx = sent command index ( Ind ): 2 digits. R = reply to command “R”: 1 digit. Yyyyyyyy = measured value: 8 digits. zzzzz = timestamp: 5 digits.

Page 20: AN401plus uk V2r11 310507 - Rom Devices\\Dse_srv5\manuali\Pitagora (AN401)\Pitagora UK\AN401plus_uk_V2r11_310507.doc Notice: The information in this manual is subject to change without

Preliminary manual AN 401 Plus V2 r11 31/05/07

-20 / 20-

9 Sales conditions ( f o r a l l D S E u r o p e p r o d u c t s )

9.1 Warranty Several electrical and mechanical tests carried out during manufacturing process and the final test carried out on each unit warrant that delivered Product is free from defects in materials, workmanship and performance. During the warranty period of six months from delivery, at no additional charge, Product rendered defective under normal use will be repaired or replaced at DS Europe factory. The Product shall be forwarded at Buyer’s expense concerning shipping, insurance, customs duties or any other charges associated with transportation of the Product. This Limited Warranty does not extend to any Product that has been damaged or rendered defective as a result of accident, misuse, or abuse. Moreover, in case of heavy or non-reparable damages, the Product may be rendered disassembled to the Buyer if the cost to re-assemble the Product will not be paid. The Product contains firmware that is provided on an “AS IS” basis: essentially, firmware is in accordance with the description of the Product manual. Except as expressly set forth in this warranty, DS Europe makes no other warranties, expressed or implied, including any implied warranties of merchantability and fitness for a particular purpose, concerning hardware and firmware of the Product and its relevant documentation. This Limited Warranty does not extend to any semiconductors: integrated circuits, transistors, diodes, microprocessors, memories and whatever else not covered by semiconductor Manufacturers’ warranty.

The Buyer shall check the delivered Product within 10 days from receipt; after this limit, the Product shall be considered accepted. DS Europe liability is limited to the above; DS Europe is not liable for any personal injuries, damages to property or damages due to stoppage of machinery or plants caused by installation and use of supplied Product (including, without any limits, any lost profits, lost savings, stoppage of activities, lost information or any other economic losses).

9.2 Damage responsibility DS Europe products are parts of more complex systems and plants; these are sold in thousands per year, for thousands different applications with thousands of norms and precautions concerning installation and use that are not known to the Manufacturer. In case of installation or use that can directly or indirectly cause personal injuries, damages to property or damages due to stoppage of machinery or plants, before installation the Buyer shall immediately advise DS Europe that will stop purchase negotiation or suspend deliveries of the Product. However, to minimize or to avoid risk of damages, DS Europe is available, without any responsibility, to suggest solutions and protection accessories, test certifications, competent Bodies or consultant Institutes. Moreover, it is recommended to read carefully installation and use instructions attached to Product delivery. These instructions can also be sent during purchase negotiation on Buyer’s request. NOTICE: Even if not expressly mentioned, these “Terms of Sale” are integral and complementary part of any bulletin, invoice or